1. on the unit s front panel the light switch switches the hood lamp on and off the motor switch switches the cooking smoke and vapour extractor motor on and off enabling you to select one of the four different speeds O i e UJ WU J a Light switch Motor On Off continuous sliding 6 switch Never leave a cooking hob or ring on without a pot or pan on top of it to avoid the possibility of excess heat damaging the unit Gas oil or coal cooker flames in particular should never be left uncovered Special care should be taken when using deep fat fryers since the oil in them can overheat and burst into flames The risk of a fat fire increases when using dirty oil Itis extremely important to note that overheating can cause afire Never carry out any flamb cooking under the hood Always disconnect the unit from the power supply before carrying out any work on the hood including replacing the light bulb take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker It is very important to clean the hood and replace the filter at the recommended intervals Failure to do so could cause grease deposits to build up causing a fire hazard Safety warnings for user Opening the grille Grease filter Carbon filter Maintenance and care The hood must always be disconnected from the mains power supply before beginning any maintenance work Open the latch L and swing the grill
2. use anon flammable outlet hose No E 647 000 012 or 647 000 010 120 mm or 100 mm from our range of special accessories The air is filtered and recirculated through the front grille Recirculating mode Move the handle F to position F Fig 3 reo AL reo AL ASPIRANTE ee F 2S Max aow MAX 2S Max aow EEEF FILTRANTE You will need an original AEG KLF60 80 activated carbon filter for the recirculating mode See special accessories Summer winter operation changeover To avoid unnecessary outdoor transport of thermal energy during exhaust air operation in winter we reccommend you to convert the fume extractor hood to winter operation return air The covering foil over the return air slots is to be removed You also need an active carbon filter special accessory When outdoor temperatures become warmer spring the active carbon filter is removed again and the fume extractor hood reset to exhaust air operation as per installation se quence The return air slots on the upper side of the appliance are to be sealed e g with self adhesive aluminium foil See also for exhaust air operation installation Voltage and current Important Electrical connections Please ensure that the voltage and current indicated on the rating plate agree with the voltage of your electricity supply If your appliance has been equipped with a mains lead with a moulded on type plug you must comply with the fo
3. 115 D Extractor Hood Installation and Operating Instructions Contents Introduction Extractor version Recirculating mode Electrical connections Safety warnings for electrician Specifications Installation Safety warnings for kitchen unit installer Wall unit mounting Wall mounting Hood operation Safety warnings for user Maintenance and care Opening the grille Grease filter carbon filter Changing the light bulb Cleaning Special Accessories Technical Assistance Service RWW 10 11 12 12 13 13 13 14 15 15 16 Printed on recycled paper AEG putting words into action Extractor version Introduction The hood is supplied as an extractor unit and can also be used with a filtering function by fitting activated carbon filters special accessory The unit features two outlet holes one of which A is located on the top of the unit while the other B is located on the rear To connect up the hose you should first fit the bayonet mounting flange C 100 or 120 mm on the outlet required if using the top outlet fix the flange in place using the screw supplied as shown in Fig 1 Close off the unused hole using the bayonet fitting caps D If using the rear hole open the air passage by removing the partition E Fig 2 Rear Top outlet hole outlet hole Move the lever F to position A Fig 3 When connecting up the hood using a telescopic wall pipe you should
4. 8 Always specify the hood model code number and serial number when ordering replacement filters This information is shown on the registration plate located on the inside of the unit The activated carbon filter can be ordered from AEG service Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard You are therefore strongly recommended to follow these instructions Disconnect the unit from the mains power supply Remove my cover Replace the old light bulb with a new light bulb 40 W max lf the light does not come on make sure the bulb has been screwed in correctly before contacting the AEG service Warning Changing the light bulb Cleaning Warning always disconnect the hood from the mains power supply before cleaning it Never insert pointed objects in the motor s protective grille Wash the outside surfaces using a delicate detergent solution Never use caustic detergents or abrasive brushes or powders Only ever clean the switch panel and filter grille using a damp cloth and delicate detergents It is extremely important to clean the unit and change the filters at the recommended intervals Failure to do so will cause grease deposits to build up that could constitute a fire hazard Special accessories Wall box 120mm E Nr 647 000 016 Wall box 100mm 647 000 020 120 mm outlet hose 647 000 012 100 mm o
5. e National and regional building regulations impose a number of restrictions on using hoods and fuel burning appliances connected to a chimney such as coal or oil room heaters and gas fires in the same room Hoods can only be used safely with appliances connected to a chimney if the room and or flat air environment combina tion is ventilated from outside using a suitable ventilation hole approximately 500 600 cm large to avoid the possibility of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Where flexible ducting is fitted the length should be no more than 3 metres with one 90 bend 2 metres with two 90 bends Bends of more than 90 will reduce the efficiency of the hood and reduce the air flow 10 Since the rule for rooms with fuel burning appliances is outlet hole of the same size as the ventilation hole a hole of 500 600 cm which is to say a larger hole could reduce the performance of the extractor hood If the hood is used in its recirculating mode it will operate simply and safely in the above conditions without the need for any of the aforementioned measures When the hood is used in its extractor function the following rules must be followed to obtain optimal operation short and straight outlet hose keep bends in outlet hose to a minimum never install the hoses w
6. e downwards Fig 7 Toremove the grille pull it forwards from the right and release it SETS The metal grease filter has been designed to absorb the grease particles that are formed during cooking and is always used irrespective of whether the hood is set up for extractor or filter operation The metal grease filter is positioned on the inside of its related support grille Leave the metal grease filter panel to soak for approximately 1 hour in very hot water with grease dissolving detergent and then rinse it with very hot water Repeat the operation if necessary Load the grease filter panel in a dishwasher selecting the most intensive washing programme and maximum temperature at least 6512C Repeat the operation if necessary The grille should be cleaned with luke warm water and non abrasive detergent when you change the filter The grease filter can be ordered from AEG service Open the grille and push on the stops M to take out the filter See Fig 7 The activated carbon filter should only be used if you want to use the hood in its recirculating mode To do this you will need an original AEG activated carbon filter see special accessories This filter cannot be cleaned or reused As a general rule the activated carbon filter should be 13 14 Removing the filter Press the stops N and remove the filter by pulling it down wards Fig
7. ith an acute angle they must always follow a gentle curve only keep the hose as large as possible 100 or 120 mm min Failure to observe these basic rules will drastically reduce the performance and increase the noise levels of the extrac tor hood Drill four6 mm holes in the base of the wall unit using the template supplied Mount the hood unit on the base of the wall unit using four 4 2 x 35 mm screws Fig 4 If using an interchangeable model fit the plastic caps supplied in any unused mounting holes Fig 5 Wall unit mounting Wall mounting Position the template on the wall Drill four 8 mm holes in the wall 2 in points H and 2 in points I Fit the four 8 mm screw anchor plugs in the wall Screw two 5 x 45 mm screws in points H but do not tighten them fully home Adjust the unit so that it is positioned at a right angle to the wall by turning the two support screws G Now hang the hood on the wall holes H Tighten the first two screws and for safety s sake screw the other two 5 x 45 mm screws into the holes in the hood Fig 6 11 12 Hood Operation The hood is fitted with a variable soeed motor The most effective use of the hood is obtained by switching it on a few minutes before you start cooking and leaving iton a for approximately 15 minutes after you have finished thus ensuring all cooking odours are eliminated The control switches are located
8. llowing regulations The plug moulded on to the lead incorporates a fuse For replacement use a5 amp BS1362 fuse Only ASTA approved or certified fuses should be used If the fuse cover carrier is lost a replacement cover carried must be obtained from an electrical goods retailer If the socket outlets in your home are not suitable for the plug fitted to the appliance then the plug must be cut off and destroyed for safety reasons and an appropriate plug fitted When wiring the plug ensure that all strands of wire are securely retained in each terminal Do not forget to tighten the mains lead clamp on the plug This unit is screened against radio interference in compliance with European Community directives 87 308 EEC EN 55014 DIN VDE 0875 Part 1 Electrical connections 230 V using fixed power supply line with plug 240 V using fixed power supply line Great Britain Fuse rating 13 amps The unit should only be connected up by an authorized electrician See rating plate for further information It is recommended that the socket for the plug is sited above the cooker hood or above the overhead cabinet This has 2 advantages 1 The socket is not visible 2 The appliance can easily be unplugged when necessary If a fixed connection is required the cooker hood should be connected by an electrical installer registered with a competent electricity company An isolating device is to be provided on the fixed wiring side Swi
9. ouble pole swiched fused spur outlet with or without pilot lamp We strongly recommend the appliance is connected by a quali fied electrician who is a member of the NICEIC who will comply with the IEE and any local regulations NOTE The terminology DOUBLE POLE means that both the live and neutral supplies are swiched and disconnected at the same time The terminations labelled SUPPLY are for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance WARNING THIS APPLIANCE MUST BE EARTHED IMPORTANT The wires in this mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminate in your spur box proceed as follows The wire which is coloured green and yellow must be connected to the terminal which is marked with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red BROWN LIVE Specifications Dimensions Height Width Depth in mm 152 599 505 Weight Net 8 7 Kg Gross 9 6 Kg Length of
10. tches with a contact opening of more than 3mm apply as isolating devices These include automatic cut out switches fuses and contactors VDE 0730 s 7 Part1 Your appliance must be connected to fixed wiring via the use of a double pole swiched fused spur outlet with or without pilot lamp We strongly recommend the appliance is connected by a quali fied electrician who is a member of the NICEIC who will comply with the IEE and any local regulations NOTE The terminology DOUBLE POLE means that both the live and neutral supplies are swiched and disconnected at the same time The terminations labelled SUPPLY are for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance IMPORTANT The wires of the mains lead supplied with this appliance are coloured in accordance with the following code Blue Neutral Brown Live As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying the ter minals in your plug proceed as follows The whire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black BLUE BROWN NEUTRAL LIVE 1 Appliances with 2 wires Appliances with 3 wires Your appliance must be connected to fixed wiring via the use of a d
11. the cable 140 cm Maximum absorbed power 230 W Motor absorption 1 x 150 W Lighting 2 x 40 W Fan powers levels levels in compliance with DIN 44971 Level Min Max Intensive Extractor 116 m h 175 m h 265 m h Filter 60 m h 145 m v h 175 m h Extractor system 100 and 120 mm Safety warnings for kitchen unit installer Installation When used as an extractor unit the hood must be fitted with a 100 or 120 mm diameter hose If the outlet hose is installed in a horizontal position it must be slanted at an angle of 10 so that the air can flow outside without impediment When installing the hood make sure you respect the follow ing minimum distance from the top edge of the cooking hob ring surfaces electric cookers 650 mm gas cookers 650 mm coal and oil cookers 700 mm min The air outlet must not be connected to chimney flues or combustion gas ducts The air outlet must under no circum stances be connected to ventilation ducts for rooms in which fuel burning appliances are installed It is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an un used chimney flue or combustion gas duct The air outlet installation must comply with the regulations laid down by the relevant authorities When the unit is used in its extractor version a sufficiently large ventilation hole must be provided with dimensions that are approximately the same as the outlet hol
12. utlet hose 647 000 010 Synthetic grease filter 660 951 157 KLF60 80 activated carbon filter 610 899 421 15 16 Technical assistance service Incase of any enquiries and faults please call AEG After Sales Service AEG Domestic Appliances Limited Head Office 217 Bath Road Slough Berks SL1 4AW Tel 01753 872506 Telefax 01753 512271 AEG Northern Service Centre AEG Scottish Service Centre Unit 20 Haigh Park Block 11 Unit 1 Haigh Avenue Dundyvan Industrial Estate Stockport Coatbridge GL Manchester SK4 1QR Lanarkshire ML5 4AQ Tel 0161 487 2205 Tel 01236 440387 Telefax 0161 474 1191 Telefax 01236 440256 Service Appointments Bristol 01179 252880 Norfolk 01603 765515 When calling please state the following 1 The model number 2 The E No 3 The F No The manufacturer reserves the right to make alterations in design and colour in the interests of technical development without prior notice If your appliance has a fault please contact our service engineer and state the following numbers E Nr 610 F Nr AEG Hausgerate AG Postfach 1036 D 90327 Nurnberg Copyright by AEG H 260 287 140 L489B Ed 05 95 159 95