Home
Digi 62533 Network Card User Manual
Contents
1. 1 4 pcs Universal Power Plugs 1 Installation and Drivers CD ROM 1 100 240 V to 12VDC Power Adapter 1 24 Inverted Communication Cable Note Ethernet cable is not supplied with unit End user must supply his or her own Ethernet cable System and Hardware Requirements e Designed to be used with Smartlog X3 systems 50440 SmartLog X3 w Dual Foot Plate Keypad amp Barcode Reader 120V 50441 SmartLog X3 w Dual Foot Plate Keypad amp Barcode Reader Euro Specs 50442 SmartLog X3 w Dual Foot Plate Laser Scanner Euro Specs CE Approved e Smartlog 6 03 software TEAM Enterprise Software or TEAM Basic Software Mounting and Installation NOTE If existing model 50460 Ethernet adapter is used model 50461 cannot be used on the same LAN due to driver conflicts We highly recommend switching over to model 50461 Ethernet adapter This technical bulletin is intended for personnel familiar with networking concept and Smartlog X3 systems Before mounting of the Ethernet adapter to wall or back plate of Smartlog X3 Ethernet adapter unit must be configure with the correct communication parameter and be assigned an IP address 1 Powering unit and Locating unit on the LAN Make sure there is an Ethernet cable LAN jack and power outlet for the Ethernet card to connect to Before powering or connecting Ethernet cable refer to Figure 2 dip switch must be set to dip 1 to the on position up and the rest off switch 2 to
2. SEMTRONICS 62533 Ethernet Adapter INSTALLATION AND OPERATING INSTRUCTIONS For sales and Service in Corporate Office For sales and service in Europe and North America contact 3651 Walnut Avenue Asia contact ESD Systems com Chino CA 91710 OK International European Headquarters www esdsystems com Phone 909 627 8178 Eagle Close Chandlers Ford sales esdsystems com Fax 909 627 7449 Hampshire SO53 4NF U K England Phone 508 485 7390 http www okintl com locations htm Fax 508 480 0257 Tel 44 0 23 8048 9100 Fax 44 0 23 8048 9109 TB 6128 Page 1 of 7 Revision 10 06 2005 DESCO INDUSTRIES INC Employee Owned SEMTRONICS 62533 Adapter Ethernet 10 100 120VAC 220VAC Installation and Operating Instructions DESCRIPTION DB9 Male Connector RJ45 Ethernet Jack Power Input Jack 9 to 30 VDC Serial Dip Switch Reset Button lI O8tsein Nd So FH 50461 ESE Ethernet t _ Adapter MAC Address Link LED MA Activity LED Power LED lt USA Power input 100 240 VAC Ethernet 10 100 T Base lt Power Adapter Communication Serial lt Australia Diagnostic Loop Back lt Europe Figure 1 Images are not actual size TB 6128 Page 2 of 7 Revision 10 06 2005 DESCO e e Packaging 1 Digi SP One Ethernet Adapter 1 Diagnostic Loop Back Key 1 Quick Start Guide 1 Release Note
3. Install hardware that I manually select for a list Advance and next e From the list below select the hardware you will be installing Scroll down to Multi port serial adapters S Multi port serial adapters and next e Select the device driver you want to install for this hardware Select Standard RealPort Device and next If it doesn t give you an option to select Standard RealPort Device click on Have Disk and the path of the driver is CD ROM Drive drivers windows win2k realport digirp inf e The wizard is ready to install your hardware It should show Standard RealPort Device click next e Discover Device The should unit should be located in the menu under model Digi One SP with an IP Address already assign to the unit Depending on how your network is setup you might need to manually enter an IP Address If you are entering the IP Address manually the port number is 771 e Select Com Names Windows should automatically give you a free comport to select You can select from the list or select the default one highlight by Windows Make sure you note this comport down you will need this information for the Smartlog X3 software There s a section where you can note down the comport number and IP Address for each unit e Completing the Add Hardware Wizard It should show Standard RealPort Device click Finish 4 Connecting Digi One Sp Hardware to Smartlog X3 TB 6128 Page
4. 4 down MFG default and the diagnostic loop back key must be securely connected to serial DB9 male port Make sure the AC power adapter supplied with model 50461 is used The AC power adapter is a 100 240VAC auto switching power adapter and can be plugged into any power outlet known with the 4 piece universal plugs TB 6128 Page 3 of 7 Serial Dip Switch Reset Button Figure 2 Diagnostic Loop Back Revision 10 06 2005 DESCO INDUSTRIES INC Employee Owned Once the unit is power up the Link and Act LED will come on for proximity 2 seconds Plug in the Ethernet network cable into the jack labeled Ethernet on model 50461 The Link LED should remain on and the Act LED should blink repeatedly If the Link LED or Act LED doesn t come on using a small screw driver or small pointy probe refer to figure 1 and 2 push and hold down the reset button for approximately 10 12 seconds you will need to power down and re power the unit first The Power LED will blink 4 times and resetting itself Using the CD ROM included in the package insert the CD ROM into the computer s CD drive Make sure you are inserting the CD ROM into the computer that is running the Smartlog X3 software this includes Smartlog 6 03 TEAM Enterprise and TEAM Basic The installation software should run automatically If the CD ROM fails to run automatically go to My Computer and open up the CD ROM drive labeled Digt Once the set up pro
5. Power Requirement 9 30Vdc 0 5A max Regulatory Approval FCC Part 15 Subpart B Class A S DeSECEMNTCoTa EN55022 Class A 50467 EN55024 EN61000 3 2 3 UL60950 CAN CSA C22 2 No 60950 3 882 EN60950 9 860cm a 5 A 0 983 a we 2 496cm 679 264 cm Figure 4 Troubleshooting e Link LED or ACT not turning on when unit is powered Power down unit re power unit and push and hold reset button for 10 12 seconds e Software cannot find or conflicts within comports Make sure you have the Diagnostic Loop Back securely connected to the serial port of model 50461 Make sure Ethernet cable is not defective or incorrectly wired Ifyou have a Lantronix comport redirector installed on the same computer you will need to un install the software e Unit not communicating with software Make sure dip is set to dip 1 on and dip 2 to 4 is off Make sure Ethernet cable is not defective or incorrectly wired Make sure the DB9 Adapter is securely connected to the serial port of model 50461 Make sure you have the 24 data cable from the Ethernet connect to right port of Smartlog X3 labeled RS 232 TB 6128 Page 6 of 7 Revision 10 06 2005 DESCO e e TECHNICAL SUPPORT USA Semtronics 3651 Walnut Avenue Chino CA 91710 Tel 909 627 8178 Fax 909 627 7449 NOTE Unauthorized servicing or modifications to your monitor will void the product warranty and may create dangerous conditions Servicing
6. should be performed only at the factory or by a Semtronics approved technician LIMITED WARRANTY Semtronics expressly warrants that for a period of one 1 year from the date of purchase Semitronics 62533 will be free of defects in material parts and workmanship labor Within the warranty period a unit will be tested repaired or replaced at our option free of charge Call Customer Service at 909 627 8178 Chino CA or 781 821 8370 Canton MA for Return Material Authorization RMA and proper shipping instructions and address Include a copy of your original packing slip invoice or other proof of date of purchase Any unit under warranty should be shipped prepaid to the Semtronics factory Warranty replacements will take approximately two weeks If your unit is out of warranty Semtronics will quote repair charges necessary to bring your unit up to factory standards Call Customer Service at 909 627 8178 for proper shipping instructions and address Ship your unit freight prepaid WARRANTY EXCLUSIONS THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY In no event will Semtronics or any
7. 4 of 7 Revision 10 06 2005 DESCO e e Smartlog Connect data X3 cable from DB9 adapter to RS 232 port of Smartlog X3 Power Adapter lt 24 Data Cable Ethernet Cable from y lt DB9 Adapter Figure 3 Refer to Figure 3 Disconnect and remove the Diagnostic Look Back from the model 50461 There should have been a DB9 Adapter included with your Smartlog X3 system connect the DB9 Adapter to the serial port of the model 50461 Connect the 24 data cable from the DB9 to the right port of the Smartlog X3 RS 232 port Make sure that no LED lights up on the right and left side of Optional Male DB15 port of the Smartlog X3 this means you have an incorrect data cable connected to the RS 232 port or you have a damaged RS 232 port Operation Refer to the instruction manual or technical bulletin for the software you are using to program and poll the Smartlog X3 Treat the unit as if it s connected directly to the comport Perform a search or on the TEAM software select the range of min and max comports model 50461 is programmed to communicate on Notes TB 6128 Page 5 of 7 Revision 10 06 2005 DESCO INDUSTRIES INC Employee Owned Specifications and Dimensions Dimensions Operation Temperature Length 3 882 in 9 860cm Ambient temperature 10 C to 45 C 50 F to 131 F Width 1 679 in 4 264cm Relative humidity 5 to 90 non condensing Depth 0 983 in 2 496cm Weight 2 290z 65g
8. gram opens up follow the direction on the screen The program will automatically find the unit on the LAN However if the unit cannot be located check to ensure the diagnostic loop back is securely connected to DB9 of model 50461 Check to make sure the unit is powered and on Check the Link and Act LED to make sure it s on 2 Assigning IP Address via Installation CD Click next after each bullet e Obtain IP setting automatically using DHCP e Select the scenario list to REALPORT Com Port Redirection e Check check box Install Digi RealPort on this computer e Click next to configure and save setting This will take a few minutes while the software communicates with the Ethernet adapter 3 Adding Hardware Multi port Serial Adapter in Windows Go to START bottom left of Windows the Start Menu will pop up and click on Control Panel If you don t see the Add Hardware icon on the left of Control Panel this is an option to switch to Classic View Click on Classic View and click on the Add Hardware icon Welcome to Add Hardware menu should pop up click on next Follow the following steps for each menu that opens up e Is the Hardware Connected Click on Yes I have already Connected the hardware and next e The following hardware is already installed on your computer Scroll down and select Add a new hardware device and next e The wizard can help you install other hardware device Check
9. seller be responsible or liable for any injury loss or damage direct or consequential arising out of the use of or the inability to use the product Before using users shall determine the suitability of the product for their intended use and users assume all risk and liability whatsoever in connection therewith TB 6128 Page 7 of 7 Revision 10 06 2005 DESCO eae oe
Download Pdf Manuals
Related Search
Related Contents
Manual_Mainboard_BasicInformation_D2000 Manual de Instalação, Operação e Manutenção design makes objects timeless, fashion corrupts them, fools copy Copyright © All rights reserved.
Failed to retrieve file