1. board from the anti static packaging until you are ready to install it Observe proper anti static precautions at all times PCI bus connector Rear bracket Configuring the Hardware The Dialogic D 82JCT U board is a PCI form factor board that uses hardware auto configuration for IRQ and memory address It allows you to use the factory default hardware settings for quick installation and operation However you should review the following information to determine if any of the optional configuration items apply to your system Setting the Board Identification Number When you start a Dialogic board each board is assigned a Board ID number for identification and use by the application program All Dialogic PCI boards with a rotary switch can share the factory default switch setting and Board ID of 0 To give a PCI board with a rotary switch a Board ID other than 0 the rotary switch is set to the desired number Because the Dialogic D 82JCT U board has no rotary switch the Dialogic Configuration Manager DCM software that is provided with the board automatically assigns Board IDs beginning with O unless there are other PCI boards with a rotary switch settings of 0 1 2 etc In that case DCM assigns the first available Board ID not in use The Board ID of the Dialogic D 82JCT U can only be changed by using DCM See the DCM help files for more information about changing Board IDs Note f you add PCI boar
2. is available from Dialogic s legal department at 9800 Cavendish Blvd 5m Floor Montreal Quebec Canada H4M 2V9 Dialogic encourages all users of its products to procure all necessary intellectual property licenses required to implement any concepts or applications and does not condone or encourage any intellectual property infringement and disclaims any responsibility related thereto These intellectual property licenses may differ from country to country and it is the responsibility of those who develop the concepts or applications to be aware of and comply with different national license requirements Dialogic Diva Eicon Eicon Networks Eiconcard and S Pcontrol among others are either registered trademarks or trademarks of Dialogic Dialogic s trademarks may be used publicly only with permission from Dialogic Such permission may only be granted by Dialogic s legal department at 9800 Cavendish Blvd 5th Floor Montreal Quebec Canada H4M 2V9 Any authorized use of Dialogic s trademarks will be subject to full respect of the trademark guidelines published by Dialogic from time to time and any use of Dialogic s trademarks requires proper acknowledgement The names of actual companies and products mentioned herein are the trademarks of their respective owners
3. Dialogic D 82JCT U PBX Integration Board Quick Install Card Board ID Display Part Number 64 0089 02 Physical Description P8 CT Bus connectoja P8 Detail Pin20 9Pin4 Pin 3 J1 36 position mini D plug connector P8 CT Bus termination jumpers Bus signals are terminated when jumper clip is installed over indicated pins Note Bus signals must be terminated only on boards at each end of the CT Bus cable Pins 1 amp 2 CT Bus SCbus termination rights reserved e e Copyright 2000 2007 T a 2g C Dialogic Corporation Before You Begin Protecting the Board from Damage CAUTION All computer boards are sensitive to electrostatic discharge ESD Handle all static sensitive boards and components at a static safe work area and observe anti static precautions at all times If you are not familiar with ESD safety precautions visit http Awww dialogic com support hwinstall to learn more Unpacking the Board Unpack the Dialogic D 82JCT U PBX Integration board board according to the following steps 1 Prepare a static safeguarded work area 2 Carefully remove the board from the shipping carton and anti static packaging Handle the board by the edges and avoid touching the board s components 3 Lay the board on the static dissipative work surface Note Place boards in static shielding bags when carrying boards from station to station CAUTION Do not remove the
4. ation jumpers Note Only the two boards at the ends of the CT Bus ribbon cable must have their terminations enabled All other boards must not have the jumper clips installed Installing the Board 1 Working with your computer at a static safe work area switch off the power and disconnect all power cords from the electrical outlets 2 Remove the chassis cover 3 Select an empty PCI expansion bus slot and remove the slot s retaining screw and access cover plate 4 If you are not installing your board in an ISA form factor PCI slot remove the ISA edge retainer bracket from the board 5 Using the slot s board guides insert the edge connector of the board into the bus slot Press firmly until the board is securely seated in the slot 6 Replace and tighten the retaining screw to secure the board firmly in the chassis slot If the screw is not installed attaching a CT Bus cable can unseat the board from the slot Installing the PCI Board 9 Remove Cover Plate Computer Chassis CI Slot 7 Repeat steps 3 6 for each board you are installing Connecting the CT Bus Cable Note If you are using the Dialogic D 82JCT U in stand alone mode where the application does not use time slot routing you do not need to connect a CT Bus cable and you may skip the instructions in this section You only need to perform this part of the installation if your system uses multiple boards and controls res
5. conductors of one station set circuit are adjacent on a standard type 66 punch down block The pattern shown in the following figure continues down the connector to encompass all eight channels with two pairs of conductors per channel for a total of 16 twisted conductor pairs Telco Plug Connector Pinout Ch 1 4 wire transmit Ch 1 4 wire transmit Ch 1 2 wire transmit receive or Ch 1 4 wire receive Ch 1 2 wire transmit receive or Ch 1 4 wire receive Ch 2 4 wire transmit Ch 2 4 wire transmit Ch 2 2 wire transmit receive or Ch 2 4 wire receive Ch 2 2 wire transmit receive or Ch 2 4 wire receive After Installing the Hardware After installing the hardware run the Dialogic Configuration Manager DCM as described in the installation instructions included with the Dialogic System Software to configure your system For technical specifications and product information go to http Awww dialogic com products htm Warranty and Return Information Warranty Period For specific warranty information for this board refer to the Warranty section of the Products page located at this URL http www dialogic com warranties Contacting Technical Support Dialogic provides technical support for its products through a network of value added distributors who are trained to answer technical questions on installing and configuring Dialogic products If you are unsure how to contact your support cha
6. ds with rotary switches to your system after Dialogic D 82JCT U boards have been assigned boards may share the same ID depending on the rotary switch settings of the new boards For instance if DCM has assigned Board IDs 01 02 and 03 to existing Dialogic D 82JCT U boards and then the rotary switches on three new Pins 3 amp 4 MVIP Bus termination CT Bus connector ECTF H 100 compliant CT Bus edge connector boards are set to 1 2 and 3 the Dialogic D 82JCT U and new boards will share Board IDs 01 02 and 03 The Dialogic D 82JCT U Board ID appears on the 2 character LED display on the rear bracket of the board along with error codes when appropriate Display Meaning 00 xx Board ID in hexadecimal 88 PCI Bus reset active DO Front end download or initialization failed E1 E8 Error on PBX port 0 7 channel 1 8 Following download the Board ID is continuously displayed on the LED unless a communications error is experienced on one or more of the PBX ports When errors are present they are displayed for two seconds alternating with the Board ID for two seconds CT Bus Termination Jumpers are used to terminate signals on the CT Bus These settings apply to boards located at physical ends of the bus For CT Bus or SCbus both CT_C8_ A amp B and CT_FRAME_ A amp B are terminated using pins 1 and 2 of the P8 termination jumpers For MVIP C 2 and C 4 are terminated using pins 3 and 4 of the P8 termin
7. nnel please call Dialogic in the United States at 973 967 6600 9am 5pm EST and we will assist in obtaining the appropriate support channel Outside the United States please refer to http www dialogic com support contact to obtain local contact information Dialogic also provides direct support via Dialogic Pro Services agreements For more details of direct support from Dialogic please refer to http www dialogic com support DialogicPro Returning a Product To return a board for warranty repair or any other returns please refer to the following http www dialogic com support hwfaults Sales Assistance If you have a sales question please contact your local Sales Representative or the Regional Sales Office for your area Address telephone and fax numbers are available at the Dialogic website located at http Awww dialogic com contact htm To purchase Dialogic products please refer to the following website to locate the appropriate supplier http Awww dialogic com purchase htm All contents of this document are furnished for informational use only and are subject to change without notice and do not represent a commitment on the part of Dialogic Corporation or its subsidiaries Dialogic Reasonable effort is made to ensure the accuracy of the information contained in the document However Dialogic does not warrant the accuracy of this information and cannot accept responsibility for error
8. ources on the boards through time slot routing The Dialogic D 82JCT U connects to other boards via the H 100 compliant Computer Telephony bus CT Bus using an optional CT Bus cable Note Full H 100 capabilities are not available with this release of the Dialogic D 82JCT U 1 Attach the end connector on the ribbon cable to the CT Bus edge connector on the top edge of the first board The connectors are designed to fit together one way only If the connector does not seat fully on the board turn the cable around and try again Make sure that the colored stripe on the cable faces toward the rear bracket The stripe should be adjacent to pin 1 on the board connector To preserve the electrical integrity of the CT Bus use a CT Bus cable with the appropriate number of connectors drops It is recommended that no more than two connectors at either end of the cable be left unused 2 Attach the ribbon cable to the next board until all boards are connected by the cable Installing the CT Bus Cable Colored Stripe Pin 1 Your CT Bus cable may have a different number of connectors drops Note To connect the CT Bus to an SCbus attach a CT Bus SCbus Adapter not included to the CT Bus board closest to the SCbus and connect the SCbus cable to this adapter See the hardware installation instructions for the CT Bus SCbus Adapter for more information 3 If the ribbon cable has extra connectors or loose cable t
9. s inaccuracies or omissions that may be contained in this document INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC PRODUCTS NO LICENSE EXPRESS OR IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT EXCEPT AS PROVIDED IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC DIALOGIC ASSUMES NO LIABILITY WHATSOEVER AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO SALE AND OR USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY Dialogic products are not intended for use in medical life saving life sustaining critical control or safety systems or in nuclear facility applications It is possible that the use or implementation of any one of the concepts applications or ideas described in this document in marketing collateral produced by or on web pages maintained by Dialogic may infringe one or more patents or other intellectual property rights owned by third parties Dialogic does not provide any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with intellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic More detailed information about such intellectual property
10. uck the cable down so that it does not snag when you replace the PC cover 4 After installing and connecting all the boards replace the PC cover cables and cords Connecting External Cabling A PBX station interface cable assembly that is specific to the Dialogic D 82JCT U available separately is used to connect the board to a punch down block Connecting the Station Interface Cable 36 position mini D cable plug To punch down block 28 GA 18 pair D 82U rear bracket shielded cable f m mi Ay Pe d 25 pair telco plug The station interface cable terminates at the punch down block end with a 25 pair 57 series Amphenol plug to allow available type 66 punch down blocks to be used to terminate the PBX station wiring A 36 position mini D connector is used on the Dialogic D 82JCT U end of the cable To connect your Dialogic D 82JCT U board to a punch down block follow the instructions below 1 Connect the station interface cable s 36 position mini D cable plug to the connector on the rear bracket of the Dialogic D 82JCT U 2 Connect the station interface cable s 25 pair telco plug to the connector on the punch down block Hardware installation is now complete Connector Pin Numbering 25 pair connector attaches to the punch down block 1 2 36 36 position connector attaches to the D 82U The Telco plug cable connector tabulation is arranged so that the four
Download Pdf Manuals
Related Search
Related Contents
User Manual - Point Of Sale Solution Netis System ST-3115 network switch TSD Series - User Manual [FR] 取扱説明書のダウンロード(PDFファイル 645KB) SHARP LEDシ一uングラィ ト@ MEGA PREX N MEGA PREX NK DUO PREX N MEGA User Manual - Pure Acoustics, Inc. C Compiler for the PIC17 Devices User`s Manual HINWEISE ZUR UMSETZUNG DER EMPFEHLUNGEN Copyright © All rights reserved.