Home

DCS EH-30SS Ventilation Hood User Manual

image

Contents

1. M 2 LIGHT ON OFF SWITCH A O n O ff switch for the halogen light Move the switch to 1 to turn the light ON and to 0 to turn it OFF BLOWER ON OFF SWITCH B O n O ff switch for the blower Move the switch to 1 to turn the blower ON and to 0 to turn it OFF BLOWER SPEED SWITCH Speed control for blower Move the switch to position 1 for LOW Speed 2 for MEDIUM speed and 3 for HIGH speed For Best Results Start the euro hood before cooking and allow the unit to operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen CLEANING The metal grease filters should be cleaned frequently in hot detergent solution or washed in the dishwasher Clean exterior surfaces with a commercially available stainless steel cleaner Abrasives and scouring agents can scratch stainless steel finishes and should not be used to clean finished surfaces REPLACINGTHE HALOGEN LAMPS WARNING Before you begin make sure that the euro hood is turned off and that the other lamps have had sufficient time to cool Halogen bulbs burn extremely hot and serious injury could result from touching a hot bulb To replace the lamp the bezel A around the lamp C must be removed The bezel A is held in place by two screws B Remove the two screws and the bezel Then remove the lamp and replace with a new lamp O nce the new lamp is in place reinstall the bezel NOTE This euro hood use
2. tefle daa aaa daas 13 HOW TO OBTAIN SERVICE 4 1 4 0402 14 WARRANTY 15 This euro hood system is designed to remove smoke cooking vapors and odors from the cooktop area WARNING ALLWALL AND FLOOR OPENINGS WHERE THE EURO HOOD IS INSTALLED MUST BE SEALED Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts MOBILE HO ME IN STALLATIO N The installation of this euro hood must conform to the Manufactured Home Construction and Safety Standards Title 24 CFR Part 3280 formerly Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements Venting system MUST terminate outside the home DO NOT terminate the ductwork in an attic or other enclosed space DO NOT use 4 laundry type wall caps Flexible type ductwork is not recommended DO NOT obstruct the flow of combustion and ventilation air Failure to follow venting requirements may result in a fire Electrical ground is required on this euro hood f cold water pipe is interrupted by plastic non metallic gaskets or other materials DO NOT use for grounding DO NOT ground to a gas pipe DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutr
3. Dynamic Cooking Systems Inc THE PROFESSIONAL EURO HOOD Use and Installation Guide Models EH 30SS E EH 36SS A Message To Our Customers Thank you for selecting this DCS Updraft Euro Hood Because of its unique features we have developed this Use and Installation Guide It contains valuable information on how to properly operate and maintain your new Updraft Euro Hood for years of safe and enjoyable cooking To help serve you better please fill out and return the Ownership Registration Card and keep this guide handy as it will help answer questions that may arise as you use your Updraft Euro Hood For your convenience product questions can be answered by a DCS Customer Service Representative by phone 1 888 281 5698 or Fax 714 372 7003 or by mail DCS Attention Customer Service 5800 Skylab Road Huntington Beach CA 92647 WARNING TO REDUCETHE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite H eat oils slowly on low or medium setting Always turn the euro hood ON when cooking at high heat or when cooking flaming foods Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCETHE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE
4. for ceilings between eight 8 2 and 9 8 Fig 05b FIG 03 EURO HOOD WITH OPTIONAL CHIMNEY FIG 04 EURO HOOD WITHOUT OPTIONAL CHIMNEY FIG 05A STANDARD INSTALLATION DIMENSIONS FRONT VIEW 1 30 or 56 30 cabinet base FIG 05B CEILING HEIGHT VARIANCES WITH OPTIONAL CHIMNEY KIT SIDE VIEW min 21 7 8 max 40 10 5 16 30 36 Chimney Cover Lower Chimney Cover 19 1 2 9 8 5 16 116 5 16 Min 8 2 5 16 98 3 16 cabinet base CALCULATETHE DUCT RUN LENGTH The duct run should not exceed 35 feet if ducted six inch 6 round ductwork Calculate the length of the ductwork by adding the equivalent feet in fig 06 for each piece of duct in the system an example is given in fig 07 For best results use no more than three 90 elbows Make sure that there is a minimum of 24 of straight duct between elbows if more than one is used Do not install two elbows together 45 Elbow 5 0 feet 9 Feet Straight Duct 9 0 feet 2 90 Elbows 14 0 feet W all Cap 0 0 feet Total System 23 0 feet 90 Elbow 7 0 feet 90 Flat Elbow 12 0 feet W all Cap 0 0 feet WARNING Personal injury hazard due to the weight and size of the euro hood canopy two or more people are needed to move and safely install the euro hood canopy Failure to properly lift euro hood could res
5. top In order to vent to the rear ductwork must run first vertical then elbow to the back The dimensions for the duct openings are given in Fig 02 Install all ductwork before installing the euro hood 6 Determine the proper location for the power supply cable as indicated in Fig 2 6 2b DO NOT turn on the power until installation is complete INSTALLING THE EURO HOOD 1 Remove the unit from the carton and place on a flat surface for assembly Cover the surface to prevent accidental damage Remove all parts including the mounting hardware before discarding the carton 2 To remove filter Pull knob forward towards you and turn to the left at same time 3 Remove the cover from the field wiring compartment Remove the wiring electrical knockout using a flat blade screwdriver Feed the power supply cable through the electrical knockout 4 The canopy attaches to the wall by two screws discussed earlier in the installation instructions The canopy hangs from these screws by brackets inside the euro hood shown in Fig 08 Before attempting to hang the canopy you should rotate the adjustment screw marked V1 in Fig 08 counter clockwise to extend the brackets from the canopy Using a Phillips head screwdriver rotate this screw counter clockwise to extend the bracket 5 Install the damper before hanging the euro hood The damper attaches to the euro hood by two small screws provided in the hardware package 6 Hang th
6. FOLLOW IN G SM OTHER FLAM ES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFULTO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE Table Of Contents SAFETY PRACTICES amp PRECAUTIONS 1 sene 3 SPECIFICATIONS i uomine dan munt e en nd 4 PLANNING THE INSTALLATION 5 INSTALLATION 5 6 11 10015 E 6 Standard Installation D 7 Ceiling H eight ear VAN COS 8 Duct RUN LENG Ace ace sete a let htt etatis s aiii 9 Wall Prepara RARER 9 10 installing Eur Ho OU tp eb an e dedans in n 10 11 Optional D uctl ss Installation KS win 11 USE AND CARE dodo d pod bo Ede 12 WIRING DIAGRAM
7. HOME warranty during the first year of ownership This does not apply if the unit was subjected to other than normal household use Service must be provided by Authorized Factory Agent during normal working hours N o charges will be made for repair or replacement at the location of initial installation or factory for parts returned pre paid through the dealer and claimed within the warranty period and found by DCS to be defective Replacement will be B DCS DCS will not be liable for any transportation costs labor costs or export duties This warranty shall not apply nor can we assume responsibility for damage that might result from failure to follow manufactures instructions or local codes where the appliance has been tampered with or altered in anyway or which in our judgement has been subjected to misuse negligence or accident Implied warranty shall not extend beyond the duration of this written warranty This warranty is in lieu of all warranties expressed or implied and all other obligations or liability in connection with the sale of this appliance DCSWILL NOT PAY FOR elnstallation or start up eShipping damage eService by an unauthorized agency eD amage or repairs due to service by an unauthorized agency or the use of unauthorized parts eService during other than normal working hours elmproper installation such as improper hook up etc eService visits to teach you how to use the appliance correct the instal
8. ION PARTS SUPPLIED FOR INSTALLATION Saber Saw or Jig Saw 1 Hardware Package Drill 1 Literature Package 1 1 4 Wood Drill Bit Pliers PARTS NEEDED FOR INSTALLATION Phillips Screwdriver 2 Conduit Connectors Flat Blade Screwdriver Power Supply C able W ire Stripper or Utility Knife e 1Wall or Roof Cap Metal Snips All Metal Ductwork MeasuringTape or Ruler Level Pencil Caulking Gun Duct Tape This euro hood can be installed with Fig 03 or without Fig 04 an optional telescopic chimney kit model 4ECD 2SS In a ducted application this euro hood can be vented through the wall or ceiling To vent through a wall a 90 elbow is used W hen installing ductless with a chimney kit the euro hood vents out of grates on the sides of the ductless chimney kit model D 2SS This ductless instal lation also requires a charcoal filter kit model ECF W hen installing ductless without the optional chimney kit some ductwork must be installed to divert the air out of the cabinet This installation requires charcoal filter kit model ECF See page 11 for more details on all ductless installations WARNING Before making any cuts or holes for installation Determine which venting method will be used and carefully calculate all measurements Standard installation for the euro hood requires the canopy to be mounted 30 above the countertop Fig 05a The optional telescopic chimney kit can be adjusted
9. TWORK ELECTRICAL REQUIREMENTS A 120 volt 60 Hz AC only electrical supply is required on a separate 15 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended The fuse must be sized per local codes in accordance with the electrical rating of this unit as specified on the serial rating plate located inside the unit near the field wiring compartment THIS UNIT MUST BE CONNECTED WITH COPPERWIRE ONLY W ire sizes must conform to the require ments of the N ational Electrical Code AN SI N FPA 70 latest edition and all local codes and ordinances W ire size and connections must conform with the rating of the appliance This appliance should be connected directly to the fuse disconnect or circuit breaker through flexible armored or non metallic sheathed copper cable Allow some slack in the cable so the appliance can be moved if servicing is ever necessary A UL Listed 1 2 conduit connector must be provided at each end of the power supply cable at the appliance and at the junction box W hen making the electrical connection cut a 1 1 4 hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet WARNING To reduce the risk of fire or electric shock DO NOT use this fan with any solid state speed control device CAUTION For General Ventilating Use Only Do Not UseTo Exhaust H azardous or Explosive Materials and Vapors TOOLS NEEDED FOR INSTALLAT
10. al or grounding circuit could result in electrical shock Check with a qualified electrician if you are in doubt as to whether the euro hood is properly grounded Failure to follow electrical requirements may result in a fire WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SH OCK OR INJURY TO PERSONS OBSERVE TH E FOLLOWING Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally W hen the service discon necting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation Work And Electrical W iring Must Be Done By Qualified Person s In Accordance W ith All Applicable Codes And Standards Including Fire Rated Construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the N ational Fire Protection Association N FPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASH RAE and the local code authorities W hen cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities NOTE Ducted fan
11. breaker is not tripped or the house fuse blown If the unit still does not operate disconnect the power supply and check that the wiring connections have been made properly DUCTLESS INSTALLATION KITS The euro hood can be installed ductless in both chimney and no chimney under cabinet installation To install ductless in a chimney installation you must have the ductless chimney kit model ECN D 255 fig 09 and the charcoal filter kit model fig 11 To install ductless in a no chimney installation under cabinet fig 10 you must have the charcoal filter kit fig 11 The ductless chimney kit consists of an upper chimney not pictured 6 lower chimney with two holes for the exhaust air a ductless 0 diverter B which sits on the canopy of the hood and diverts the air to the sides of the chimney and two vent grates C to cover the holes in the lower chimney The charcoal filter kit contains two charcoal filters which twist onto either side of the blower inside the euro hood W hen installing ductless without the optional chimney kit some ductwork must be installed to divert the air either out of the top of the cabinet or to the face of the soffit The duct work can not terminate inside the cabinet or into any dead air space E Care Information CONTROL PANEL The control panel is located on the right hand side under the canopy
12. e euro hood canopy from the screws Due to the weight of the canopy these screws must be installed into solid material O nce the canopy is hung rotate the screw marked V1 to secure the euro hood to the wall NOTE Make sure that the euro hood is securely attached to the wall Failure to properly install could result in injury or damage to property continued on page 11 7 The brackets shown in Fig 08 are also used to adjust the level of the canopy Using a Phillips screwdriver rotate the screw V2 to adjust the level of the canopy 8 Connect the Power Supply Cable to the euro hood Attach the White lead of the power supply to the W hite lead of the euro hood with a twist on type wire connector Attach the Black lead of the power supply to the Black lead of the euro hood with a twist on type wire connector Connect the Green Green and Yellow ground wire under the Green grounding screw 9 Replace the field wiring compartment cover and the grease filters To install grease filter Put the end of grease filter without the knob into the channel in the front of hood Turn knob to the left so the lever does not protrude from filter Insert knob end of grease filter into the channel in the back of the hood Turn knob to the right locking filter in place 10 the power supply on Turn on blower and light The euro hood controls are located on the right hand side under the canopy If the euro hood does not operate check that the circuit
13. lation reset circuit breakers or replace home fuses eRepairs due to other than normal household use eD amage caused from accident abuse alteration misuse incorrect installation or installation not in accordance with local codes eUnits installed in non residential application such as day care centers bed and breakfast centers churches nursing homes restaurants hotels schools etc This warranty applies to appliances used in residential applications it does not cover their use in commercial situations This warranty is for products purchased and retained in the 50 states of the U S A the District of Columbia and Canada This warranty applies even if you should move during the warranty period Should the appliance be sold by the original purchaser during the warranty period the new owner continues to be protected until the expiration date of the original purchaser s warranty period This warranty gives you specific legal rights You may also have other rights which vary from state to state DCs 5800 Skylab Road Huntington Beach CA 92647 Tel 714 372 7000 Fax 714 372 7001 Parts Customer Service 888 281 5698 www dcsappliances com As product improvement is an ongoing process at DCS we reserve the right to change specifications or design without notice Part N o 17386 Rev A Litho in USA 06 2001
14. s 20 watt Halogen Lamps Wiring Diagram E 36 Hoods Slide Switches LIGHT 04 1 2 SPEED WIRING BOX TOROIDAL TRANSFORMER DIRECTIONAL LAMPS lt lt lt 1 2 3 CONDENSATORE TENSIONE 10 u F 400 V 200 240 V 50 60 Hz 25 F 240 V 120V 60 Hz 100 V 50 60 Hz MOTOR GROUP Sewice HOW TO OBTAIN SERVICE Before you call for service 1 Is the circuit breaker tripped or the fuse blown 2 Is there a power outage in the area For warranty service contact your local DCS authorized service agency Provide service agency with the Model N umber Serial N umber and date of installation and a brief description of the problem If you need assistance in locating the authorized service agency in your area please contact our DCS Consumer Service Department for an authorized service agent near you our number is 888 281 5698 Your satisfaction is of the utmost importance to us If a problem cannot be resolved to your satisfaction please write or fax us at Write DCS Attention Consumer Relations 5800 Skylab Road Huntington Beach CA 92647 Fax us at 714 372 7003 LENGTH OFWARRANTY One 1 Year Full parts and Labor Covers the entire product Five 5 Year Limited warranty covering the switches and motor DCSWILL PAY FOR All repair labor and parts found to be defective due to materials or workmanship for one full year IN
15. s must always be vented to the outdoors FIG 01Hood with optional Chimney 7 12 lg 3 4 7 8 29 7 8 30 Hood 35 7 8 36 Hood 19 1 2 tese 20 7 8hin to 40 max 10 5 16 2 15 16 FIG 02a Duct Bracket Electrical Dimensions 30 Hood 2504 2 15 16 FIG 02b Duct Bracket Electrical Dimensions 36 Hood Planning The Installation VENTING REQUIREMENTS Determine which venting method is best for your application Ductwork can extend either through the wall or the roof The length of the ductwork and the number of elbows should be kept to a mini mum to provide efficient performance The size of the ductwork should be uniform Do not install two elbows together Use duct tape to seal all joints in the ductwork system Use caulking to seal exterior wall or floor opening around the cap Flexible ductwork is not recommended If it is used each foot of flexible ductwork used is equivalent to two feet of straight metal ductwork when calculat ing the duct run length Thus a flexible elbow equals two standard elbows Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts Do not cut a joist or stud unless absolutely necessary If joist or stud must be cut then a supporting frame must be constructed WARNING TO REDUCETHE RISK OF FIRE USE ONLY METAL DUC
16. ult in damage to the product or personal injury WALL PREPARATION WARNING The screws provided for mounting this euro hood must be inserted into solid wood These must not be inserted into sheet rock 1 Disconnect and move freestanding range from cabinet opening to provide easier access to upper cabinet and rear wall Put a thick protective covering over cooktop set in range or countertop to protect from damage or dirt 2 Determine and clearly mark with a pencil the centerline on the wall where the euro hood will be installed 3 The euro hood attaches to the wall by mounting screws For the 30 and 36 models there are two mounting screws Install the screws into the wall The screws should be inserted into the wall until the screw head is flush with the wall 4 The optional chimney kit is adjustable and designed to meet varying ceiling heights The chimney attaches to the wall by two additional brackets The top bracket should be installed about 1 8 away from the ceiling The middle bracket must be installed at the bottom point of the upper chimney sleeve Determine the proper location for each bracket and install the brackets on the wall Attach the bottom of the lower chimney to the canopy using the screws provided CAUTION Make sure that the screws and brackets are securely fastened to the wall 5 Determine and make all necessary cuts in the wall for the ductwork Each euro hood is shipped from the factory vented through the

Download Pdf Manuals