Home

CyberPower Systems 1000 Power Supply User Manual

image

Contents

1. STORAGE First turn off your UPS and disconnect its power cord from the wall outlet Disconnect all cables connected the UPS to avoid battery drain To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to insure battery life If the battery remains uncharged for an extended period of time it may suffer permanent loss of Capacity TROUBLE SHOOTING Problem Possible Cause Solution Recharge the battery by leaving the UPS The UPS doesnot Batteries are not fully charged plugged in perform expected FUALIN Battery is slightly worn out se by eet eel al The on off switch is designed to prevent damage by rapidly turning it off and on The UPS will not The unit is not connected to an The unit must be connected to a 220 240V turn on AC outlet 50 60Hz outlet Contact CyberPower Systems at i Contact CyberPower Systems at Turn the UPS off and unplug at least one piece connected equipment Unplug the power cord of the UPS then remove the fuse compartment beneath the power inlet of the UPS and replace Fuse is blown due to overload the blown fuse with a spare one Lock the compartment back to the UPS Connect power cord then turn the UPS on Make sure that your spare fuse meets the specification 6 3A 250V 5x10mm Batteries are discharged Allow the unit to recharge for at least 4 hours Unit has been damaged by a Contact CyberPower Systems at surge o
2. CyberPower eu cyberpowersystems com Office Tower Series UPS 500 750 1000 1500VA User Manual K01 0500E00 01 SAFETY WARNINGS SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate your UPS This equipment can be operated by any individuals with no previous training The socket outlet shall be installed near the equipment and easily accessible During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary Do not dispose of batteries in a fire the battery may explode Do not open or mutilate the battery or batteries released electrolyte is harmful to the skin and eyes INSTALLING YOUR UPS SYSTEM UNPACKING Inspect the UPS upon receipt The box should contain the following UPS Unit PowerPanel Plus Software Disk x 1 Serial Interface Cable DB 9 x 1 Telephone Cable x 1 Power Cord OP500E OP7
3. 50E x2 Power Cord OP1000UE OP1500UTE x4 USB Cable x 1 User Manual PowerPanel Plus Software User Manual HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Insure that the equipment plugged into the battery power supplied outlets does not exceed the UPS unit s rated capacity 500VA 300W for OP500E 750VA 450W for OP750E 1000VA 700W for OP1000UE 1500VA 900W for OP1500UTE If rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 2 If the power requirements of your equipment are listed in units other than Volt Amps VA convert Watts W or Amps A into VA by doing the calculations below Note The below equation only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any one time Users should expect usage requirements to be approximately 60 of below value TO ESTIMATE POWER REQUIREMENTS 1 ss Watts W x 2 0 VA or Amps A x 230 ___ VA 2 Add the totals up for all pieces of equipment and multiply this total by 0 6 to calculate actual requirements There are many factors that can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s capacity HARDWARE INSTALLATION GUIDE 1 Connect the equipment to your UPS outlets The IEC IEC power cords coming with the unit
4. D BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit 5 Batteries are consider HAZARDOUS WASTE and must be disposed of properly Contact your local government for more information about proper disposal and recycling of batteries Turn off and unplug all connected equipment Turn the UPS off and unplug it from the AC power source Turn the UPS upside down o N OD BATTERY REPLACEMENT PROCEDURE 1 Remove the 2 retaining screws then push the battery cover backward and remove the cover 2 Lean the UPS to one side and pull out the battery partially from the compartment Disconnect the battery wires from the battery and then remove the battery from the compartment REMINDER For OP1000E OP1500TE 2 batteries are attached with one single plastic A strip You can pull the plastic strip to pull out the battery 3 Install the replacement battery by connecting the red wire to the positive terminal of the battery and connecting the black wire to the negative terminal of the battery 4 Slide the battery back into the compartment Turn the UPS upside down to help the batteries entirely slide into the compartment Replace the cover and the retaining screws REMINDER Recharge the unit for 4 8 hours to ensure the UPS performs expected runtime
5. PS on 13 for OP500E 750E 15 for OP1000UE 1500UTE 12 for OP500E 750E 13 for OP1000UE 1500UTE For more information visit eu cyberoowersystems com or contact CyberPower Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands TEL 31 0 40 2348170 FAX 31 0 40 2340314 E MAIL sales cyberpower eu com CyberPower Systems Inc USA 4241 12th Avenue East Suite 400 Shakopee MN 55379 U S A Tel 1 952 4039500 Fax 1 952 4030009 E MAIL sales cyberpowersystems com Entire contents copyright 2004 CyberPower Systems B V All rights reserved Reproduction in whole or in part without permission is prohibited PowerPanel and PowerPanel Plus are trademarks of CyberPower Systems USA Inc CyberPower warrants to you the original purchaser that CyberPower UPS will be free from defects in design assembly materials and workmanship for two years battery is only one year from the date of original purchase Any warranty services please contact your local dealers or distributors
6. are used to connect your computer and monitor to the UPS Items such as copiers laser printers vacuums space heaters or other large electrical devices should not be connected to the UPS Please make sure that the total loads of your equipments are less than the maximum total power load of your UPS cs PLUG IM Your Computer s Power Cord 2 Use your computer power cord to connect the UPS to a wall outlet Please avoid using extension cords and adapter plugs To maintain optimal battery charge leave the UPS plugged in at all times 3 Press the UPS power button to turn it on The Power On indicator will be illuminated in Green 4 Install your software and accessories To use the software simply connect the enclosed serial interface cable to the serial port on the UPS and an open serial port on the computer BASIC OPERATION FRONT PANEL AND REAR PANEL DESCRIPTION OP1000UE 1500UTE OP500E 750E Power Switch Press the power button to turn the UPS ON or OFF Power On Indicator T This LED is illuminated when the utility condition is normal and the UPS outlets are on providing clean power free of surges and spikes ON Using Battery Indicator a This illuminates during utility failure indicating that the battery is supplying power to O the battery power supplied outlets USING BATTERY Boost Indicator This LED indicates that the UPS is operating in automatic voltage regu
7. he UPS service provided by Windows 98 Windows ME Windows NT Windows 2000 Windows XP Windows Server 2003 Ethernet RJ 45 Network Protection Ports These ports are the protection for your computer network cable BATTERY REPLACEMENT AND STORAGE CAUTION Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery under the supervision of personnel knowledgeable of batteries and their precautions Keep unauthorized personnel away from batteries If you have questions contact your dealer or call the number in this manual for information on battery replacement CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present the risk of electrical shock Do not dispose of batteries in a fire as it may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Release electrolyte is harmful to the skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 DO NOT lay tools or other metal parts on top of battery or any battery terminals 4 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDE
8. lation mode When the led is illuminated continuously it indicates that input under voltage and that O l Boost the UPS unit boosts input voltage Buck Indicator This LED indicates that the UPS is operating in automatic voltage regulation mode When the led is illuminated continuously it indicates that input over voltage and that EA the UPS unit bucks the voltage Battery Backup and Surge Protection Outlets The UPS provides battery powered and surge protected outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against surges and spikes The UPS provides surge protected only outlet for connected equipments against surges and spikes Serial Port to PC This port allows connection and communication from the DB 9 serial or USB port on E the computer to the UPS unit The UPS communicates its status to the PowerPanel Plus software This interface is also compatible with the UPS service provided by Windows 98 Windows ME Windows NT Windows 2000 Windows XP Windows Server 2003 REMINDER For contact closure communication function please log onto our website at eu cyberpowersystems com to download the contact closure software patch USB Type B Port to PC This Port allows connection and communication from USB port gn the computer to the UPS unit The UPS communicates its status to the PowerPanel Plus software This i interface is also compatible with t
9. r spike sales cyberpower eu com Connect the serial USB cable to the UPS unit The serial USB cable is not and an open serial port on the back of the connected computer You must use the cable that came with the unit The serial USB cable is PowerPanel Plus connected to the wrong port Try another serial USB port of your computer is inactive all icons are gray ia Shutdown your computer and turn the UPS off eels is not providing battery Wait 10 seconds and turn the UPS back on P i This should reset the unit The serial cable is not the cable You must use the cable included with the unit that was provided with the unit for the software Turn the UPS off Wait 10 seconds and then turn the UPS on Outlets do not provide power to equipment TECHNICAL SPECIFICATIONS OP500E OP750E OP1000UE OP1500UTE Capacity VA 500VA 1500VA Capacity Watts 300W 900W Input Input Voltage Range 220 240Vac Frequency Range 50 60 Hz Output On Battery Output Voltage On Battery Output Frequency Overload Protection On Utility Fuse On Battery Internal Current Limiting Surge Protection and Filtering Lightning Surge Protection Network Protection RJ45 One In One Out Physical Total of UPS Receptacles Maximum Dimensions 28 3cm 9 1cm 16 4cm 30 9cm 14 1cm 18 4cm Weight Kg 6 5 14 2 Battery Sealed Maintenance Free Lead Acid 12V 7 2AHx1 12V 9AHx1 12V 7 2AHx2 12V 9AHx2 Battery User Replaceable Yes Hot Swappable Batter
10. y Pack Typical Recharge Time Warning Diagnostics Indicators Power On Using Battery Boost Buck Audible Alarms On Battery Low Battery Overload Environmental Operating Temperature Operating Relative Humidity Communication PowerPanel Plus Software Simulated Sine Wave at 230Vac 7 50 60 Hz Yes 8 Hours 32 F to 95 F 0 C to 35 C 0 to 95 NON CONDENSING Windows 98 ME 2000 NT XP Server 2003 Management Yes Condition Max boost 18 15 of input voltage for output Off Normal Off regulation while input voltage is from 11 to 22 under nominal Max buck 12 13 of input voltage for output Off Normal Off regulation while input voltage is from 9 to 17 over nominal Utility Failure The UPS is providing battery power to the Battery Power Supplied outlets Utility Failure The UPS is Rapid providing battery power The Normal Beeps rapid beeps indicate the battery will run out of charge within a few minutes Overload Occurs in the Full time Two Surge Protection Outlets Please beeps or turn the UPS off and unplug at On Off On Off On Off Blown asi least one piece of equipment from beeps the UPS Replace the fuse with a spare one then turn the UPS on Overload Occurs in the Battery power Supplied Outlets Normal Lon Turn the UPS off and unplug at On Off On Off On Off Blown aes least one piece of equipment from the UPS Check the fuse and do the replacement if necessary Turn the U