Home
Crestron electronic CLW-SW1/4RF Switch User Manual
Contents
1. CRESTRON Functional Summary The GLA PWSSO0 is a 50 Watt Cresnet Power Supply designed for use with a Crestron Green Light system or anywhere a wall mountable Cresnet power supply is needed The GLA PWS50 mounts conveniently over a 4 square or 2 gang electrical box All connections are made inside the electrical box via flying leads using twist on wire connectors A partition is included to isolate high voltage from Class 2 wiring within the box 50 Watt Cresnet power supply Powers the IPAC and other Cresnet devices Provides backup power for Crestron Green Light cabinets Mounts to a 4 square or 2 gang electrical box Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 Tel 888 CRESTRON Fax 201 767 7576 www crestron com GLA PWS50 Specifications GLA PWSS50 Specifications SPECIFICATION DETAILS Output Power Output Power 50 Watts 2 1 Amps 24 Volts DC regulated limited power source Ripple Noise lt 1 Power Requirements Input 0 6 Amps 100 240 Volts AC 50 60 Hz Enclosure Metal construction mounts to a 4 inch square or 2 gang electrical box includes low voltage partition Environmental Temperature 32 to 104 F 0 to 40 C Humidity 10 to 90 RH non condensing Heat Dissipation 26 BTU Hr Dimensions Height 4 00 in 10 16 cm Width 5 55 in 14 09 cm Depth 2 27 in 5 76 cm Weight 1 2 lbs 0 54 kg Installation Guide DOC 6734A 2022081 02 09 Spec
2. of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse accidental damage modification or improper installation procedures Furthermore this warranty does not cover any product that has had the serial number altered defaced or removed This warranty shall be the sole and exclusive remedy to the original purchaser In no event shall CRESTRON be liable for incidental or consequential damages of any kind property or economic damages inclusive arising from the sale or use of this equipment CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party CRESTRON shall at its option repair or replace any product found defective without charge for parts or labor Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty Except as expressly set forth in this warranty CRESTRON makes no other warranties expressed or implied nor authorizes any other party to offer any warranty including any implied warranties of merchantability or fitness for a particular purpose Any implied warranties that may be imposed by law are limited to the terms of this limited warranty This warranty statement supersedes all previous warranties Trademark Information All brand names product names and trademarks are the sole property of their respective owners
3. EN TNE 2022663 QUAN 1 ert ri ESS at PLASTIC RIVET 2005423 QUAN 3 Hardware Hookup WARNING RISK OF SERIOUS PERSONAL INJURY Turn off power at the circuit breaker s prior to installation Installing with power on can result in serious personal injury and damage to the device 1 Use two twist on wire connectors to secure the Class 2 wiring to the Cresnet network as shown in the following diagram Connect Class 2 Wiring Partition and High Voltage Wiring Removed for Clarity 24 G y lo ol d 2 Use three twist on wire connectors on the line input wires to connect to the line power as shown in the following diagram Connect High Voltage Wiring Partition and Class 2 Wiring Removed for Clarity NEUTRAL WHITE HOT GROUND BLACK GREEN Installation Guide DOC 6734A Installation The GLA PWS50 mounts over a 4 square or 2 gang electrical box Refer to the following diagram when installing the GLA PWSS0 NOTE Ensure that the wires will not be pinched during the installation process by pushing the wires into the electrical box Install GLA PWS50 Wires Removed for Clarity Ln 4X4 ELECTRICAL BOX NOT SUPPLIED _ P oa GLA PWS50 p 4X4 ELECTRICAL BOX COVER SCREWS oxo NOT SUPPLIED QUAN 4 NOTE The GLA PWSS0 should never be installed with the label facing down e To ensure proper ventilatio
4. Windows is a registered trademark of Microsoft Corporation Windows95 98 Me XP Vista and WindowsNT 2000 are trademarks of Microsoft Corporation Installation Guide DOC 6734A
5. ifications subject to change without notice 50 Watt Cresnet Power Supply Crestron GLA PWS50 Industry Compliance As of the date of manufacture the GLA PWS50 has been tested and found to comply with specifications for CE marking CE NOTE This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit diffe
6. n do not cover the ventilation holes on the front of the unit e Turn on the circuit breaker after completing installation The green LED will illuminate Fuse Replacement If the GLA PWS50 does not power up when it is connected to line power the fuse may need to be replaced The fuse holder is located on the right side of the power supply next to the LED To replace the fuse 1 Disconnect power to the GLA PWS50 2 Use a flat head screwdriver to push in the fuse holder 3 While pushing in the fuse holder turn screwdriver counterclockwise until the fuse holder pops out 4 Remove the fuse from the fuse holder and insert a new fuse FUSE TYPE 5 x 20mm 3 15A Time Lag Wall Mount 50 Watt Cresnet Power Supply GLA PWS50 e 5 50 Watt Cresnet Power Supply Crestron GLA PWS50 CAUTION Only use the specified type of fuse when replacing a blown fuse Failure to do so may cause damage to the GLA PWS50 5 Insert the fuse holder into the GLA PWS50 6 Push in the fuse holder with a flat head screwdriver While pushing in the fuse holder turn the screwdriver clockwise until the fuse holder sinks in 7 Push in the fuse holder a little further and turn the screwdriver clockwise until the fuse holder locks in place 8 Connect power to the GLA PWS50 Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations If further assistance is required please contact a Cre
7. ntrol network or directly to a TTPO n ES h 24 Volt DC powered Crestron Teese OCO PN device O DC output fuse T3 15AH 10 16cm 5x20mm 250V 3 15A time ot Ce SoO h a lag ceramic cartridge fogeescceses H 24VDC LED 1 green LED indicates 24 i Volts DC output extinguishes l when fuse is blown 5 03 in 12 77 cm GLA PWS50 Set u p Important Notes Read before installation T i e Permits An electrical permit shall be obtained prior to each installation e Codes Install in accordance with all local and national electrical codes e Wiring Use 75 C copper wire only e Not suitable for Hazardous Classified areas Er Supplied Hardware T The hardware supplied with the GLA PWS50 is listed in x Ee the following table ooo be FE mn ve i bs UUL III Cee Supplied Hardware for the GLA PWS50 ee SS ey a Partition 2022663 1 Plastic Rivet 2005423 3 Twist On Wire Connector 2005432 5 4 e Wall Mount 50 Watt Cresnet Power Supply GLA PWS50 Installation Guide DOC 6734A Crestron GLA PWS50 50 Watt Cresnet Power Supply Assembly The GLA PWS50 comes with a partition to isolate high voltage from Class 2 wiring when installed in an electrical box Refer to the following diagram when mounting the partition on the GLA PWS50 Install the Partition PARTITION A p
8. orization RMA number Authorized returns must be shipped freight prepaid to CRESTRON 6 Volvo Drive Rockleigh N J or its authorized subsidiaries with RMA number clearly marked on the outside of all cartons Shipments arriving freight collect or without an RMA number shall be subject to refusal CRESTRON reserves the right in its sole and absolute discretion to charge a 15 restocking fee plus shipping costs on any products returned with an RMA 3 Return freight charges following repair of items under warranty shall be paid by CRESTRON shipping by standard ground carrier In the event repairs are found to be non warranty return freight costs shall be paid by the purchaser CRESTRON Limited Warranty CRESTRON ELECTRONICS Inc warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three 3 years from the date of purchase from CRESTRON with the following exceptions disk drives and any other moving or rotating mechanical parts pan tilt heads and power supplies are covered for a period of one 1 year touchscreen display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms
9. rent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 2 e Wall Mount 50 Watt Cresnet Power Supply GLA PWS50 Installation Guide DOC 6734A Crestron GLA PWS50 50 Watt Cresnet Power Suppl Application The following diagram shows a GLA PWSS50 module in a typical application OCCUPANC SENSORS 9 IN GLA PWS50 in a Lighting Application EMERGENCY TRANSFER SWITCH PHOTOCELL s KJP GENERATOR AmMZ0OmMDO OWDAZOO now GOUIAQ RoomView SERVER Color Key Control Cresnet LAN AC 24VDC Crestron RoomView lA pow Installation Guide DOC 6734A Wall Mount 50 Watt Cresnet Power Supply GLA PWS50 e 3 50 Watt Cresnet Power Suppl Crestron GLA PWS50 Connectors Controls amp Indicators m m CONNECTORS DESCRIPTION Physical Description ae Pia This section provides information on the connections controls and indicators available on the GLA PWSSO LINE POWER 3 6 flying leads 18 AWG line power input GLA PWS50 Overall Dimensions Hot black neutral white and ground green yellow EE V6 al connections i OUTPUT 2 6 flying leads 18 AWG Cresnet power output 24 VDC red G black white O connections i 5 55 in E 2 15 in Connects to 24 and G 14 09 cm l 5 45 om T aaron connections of the Cresnet ees ey ls co
10. stron customer service representative GLA PWS50 Troubleshooting TROUBLE POSSIBLE CORRECTIVE CAUSE S ACTION LED does Circuit breaker is off Verify that circuit not turn on breaker is on Fuse is blown Check fuse and replace if necessary GLA PWS50 is not Verify wiring properly connected Further Inquiries If you cannot locate specific information or have questions after reviewing this guide please take advantage of Crestron s award winning customer service team by calling Crestron at 1 888 CRESTRON 1 888 273 7876 You can also log onto the online help section of the Crestron website www crestron com onlinehelp to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available features 6 e Wall Mount 50 Watt Cresnet Power Supply GLA PWS50 Return and Warranty Policies Merchandise Returns Repair Service 1 No merchandise may be returned for credit exchange or service without prior authorization from CRESTRON To obtain warranty service for CRESTRON products contact an authorized CRESTRON dealer Only authorized CRESTRON dealers may contact the factory and request an RMA Return Merchandise Authorization number Enclose a note specifying the nature of the problem name and phone number of contact person RMA number and return address 2 Products may be returned for credit exchange or service with a CRESTRON Return Merchandise Auth