Home

Craftsman 919.167461 Air Compressor User Manual

image

Contents

1. 205 27 IMPORTANTES INSTRUCCIONES DE SEGURIDAD 27 32 GLOSARIO ccoo srt a a tido 33 ACCESORIOS voded batida alas did 33 CICLO DE SERVICIO o occ 33 ENSAMBLADO 0 0 00 cece eee cece cece e eens 34 INSTALACI N 0 0 000 cece eee eee eee eee eens 34 35 OPERACI N is ccc e s 5 540 BSS SRE Blane sia te iaa ns 36 38 MANTENIMIENTO 000 cece cece cece e eens 39 SERVICIOS Y REGULACIONES 000 cece eee eee eee ee 40 41 ALMACENAJE 0 0000 c cece eee eee e eee e eee eee eens 42 GU A DE DIAGN STICO DE PROBLEMAS 2000 43 45 NOTES NOTAS 0 0 0 00 cc cece eee cece eee e sees ee eee es 46 CONTRATOS DE PROTECCI N PARA REPARACIONES 47 LISTA DE PARTES 22 25 COMO SOLICITAR PIEZAS PARA REPARACI N contratapa GARANTIA GARANT A TOTAL DE UN A O DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricaci n dentro del a o de su fecha de compra Sears a su opci n lo reparar o reemplazar sin costo alguno Comun quese con el Centro de Servicio Sears m s cercano 1 800 4 MY HOME para coordinar su reparaci n o devuelva el compresor de aire al lugar donde lo compr para que lo cambien Si este compresor de aire se usase con fines comerciales o para alquiler esta garant a se aplica s lo durante los prime
2. D28071 44 SP CORRECCION Si hubiese una ca da excesiva de presi n durante el uso del acceso rio ajuste el regulador de acuerdo a las instrucciones de la secci n Operaci n NOTA Ajuste la presi n regulada bajo condiciones de flujo mientras se est usando el acceso rio Opere manualmente la v lvula de seguridad extray ndola por su anillo Si la v lvula pierde deber ser reemplazada Disminuya la cantidad de uso de aire Verifique el requerimiento de aire del accesorio Si es mayor que SCFM o la presi n suministrada por su compresor de aire se necesita un compresor de mayor capacidad Verifique y reemplace si fuese necesario Extraiga limpie o reemplace Ajuste las conexiones Limpie o reemplace el filtro de entrada de aire No opere el com presor de aire sin el filtro Consulte el p rrafo Filtro de Aire en la secci n Mantenimiento Limpie o reemplace Ver el p rrafo filtro de aire en la secci n Mantenimiento H gala verificar por un t cnico entrenado H gala verificar por un t cnico entrenado PROBLEMA El motor no fun ciona Golpeteo CAUSA El interruptor de protecci n des obrecarga del motor se ha abier to La presi n del tanque excede la presi n de corte m ximo del interruptor de presi n La v lvula de retenci n se ha quedado abierta Conexiones el ctricas sueltas Posible motor o capacitor de arranque defectuosos Rociado de pintura
3. cleaned or replaced 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Set the On Auto Off lever to OFF and unplug unit m Agen In open 3 Using an adjustable wrench position loosen outlet tube nut at air tank nothing is and pump Carefully move outlet visible tube away from check valve In closed position disc is visible Pressure Relief Tube 7 Clean or replace the check valve A solvent such as paint or var nish remover can be used to clean the check valve 8 Apply sealant to the check valve threads Reinstall the check valve turn clockwise 9 Replace the pressure release tube Tighten nuts 10 Replace the outlet tube and tighten nuts 11 Perform the Break in Procedure See Break in Procedure in the Operation section 17 ENG D28071 STORAGE Before you store the air compressor make sure you do the following 1 Review the Maintenance sec tion on the preceding pages and perform scheduled maintenance as necessary 2 Set the On Auto Off lever to OFF and unplug unit 3 Turn the regulator counterclock wise and set the outlet pressure to zero 4 Remove the air tool or accesso ry 5 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank D28071 Risk of Burstin
4. viding an escape wire for the elec tric current This air compressor must be properly grounded The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug see following illustra tions The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet D28071 IMPORTANT The outlet being used must be installed and grounded in accordance with all local codes and ordinances 2 Make sure the outlet being used has the same configuration as the grounded plug DO NOT USE AN ADAPTER See illustra tion moe Z UE grounded amp Outlets ee Pin 3 Inspect the plug and cord before each use Do not use if there are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly ground ed have the installation checked by a qualified electrician ADANGER Risk of Electrical Shock Improper grounding can result in electrical shock Do not modify the plug provided If it does not fit the available outlet a correct outlet should be installed by a qualified electrician Repairs to the cord set or plug MUST be made by a qualified elec trician 10 ENG Extension Cords Using extension co
5. JUSTE Una v lvula de retenci n defec tuosa causa una fuga constante de aire en la v lvula de alivio de presi n cuando hay presi n en el tanque y se apaga el compre sor Reemplace la v lvula de retenci n Consulte C mo Reemplazar o Limpiar la V lvula de Retenci n en la secci n Servico y Ajustes Contacte a un t cnico calificado en servicio El tanque de aire debe ser reem plazado No repare la perdida A ADVERTENCIA a Explosi n No perfore suelde ni modifique el tanque en forma alguna porque se debilitar Contacte a un t cnico calificado en servicio D28071 CAUSA Es normal que ocurra alg n descenso en la presi n PROBLEMA La lectura de la presi n sobre un man metro si viene equipado con ste desciende cuando se utiliza un acce sorio Posible defecto en la v lvula de seguridad P rdida de aire en la v lvula de seguridad El compresor no esta suministran do suficiente can tidad de aire para operar los acce sorios Excesivo y prolongado uso del aire El compresor no tiene sufi ciente capacidad para el requerimiento de aire al que est sometido Orificio en la manguera V lvula reguladora restringida P rdida de aire Filtro de entrada de aire restringido Toma de aire Filtro de aire sucio restringida El regulador tiene Regulador da ado una fuga continua de aire El regulador no cierra la salida del aire Regulador da ado
6. does not work properly over pressurization may occur causing air tank rupture or an explosion 1 Before starting compressor pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF and unplug unit 2 Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero 3 Remove the air tool or accesso ry 4 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi Release safety valve ring 5 Drain water from air tank by opening drain valve counter clockwise on bottom of tank AWARNING Risk of Bursting Water will con dense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture D28071 6 After the water has been drained close the drain valve clockwise The air compressor can now be stored NOTE If drain valve is plugged release all air pressure The valve can then be removed cleaned the reinstalled D28071 Air Compressor Pump Intake and Exhaust Valves Once a year have a Trained Service Technician check the air compressor pump intake and exhaust valves Motor The motor has an automatic reset thermal overload protector If the motor overheats for any reason the overlo
7. in place The compressor is ready for use NOTE Always operate the air com pressor in well ventilated areas free of gasoline or other combustible vapors If the compressor is being used to operate a sprayer DO NOT place near the spray area 14 ENG MAINTENANCE Customer Responsibilities Check Safety Valve Drain Tank Air Filter Air compressor pump intake and exhaust valves 1 more frequent in dusty or humid conditions Risk of Unsafe AWARNING Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources com pressed air or moving parts Before servicing unit unplug or dis connect electrical supply to the air compressor bleed tank of pres sure and allow the air compressor to cool To ensure efficient operation and longer life of the air compressor unit a routine maintenance schedule should be prepared and followed The following routine maintenance schedule is geared to an unit in a normal working environment operat ing on a daily basis If necessary the schedule should be modified to suit the conditions under which your compressor is used The modifica tions will depend upon the hours of operation and the working environ ment Compressor units in an extremely dirty and or hostile environ ment will require a greater frequency of all maintenance checks 15 ENG To Check Safety Valve AWARNING Risk of Bursting If SWEARING the safety valve
8. and is always less than or equal to the tank pressure Tank Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure gauge Pull the knob out and turn clockwise to increase pressure and counter clockwise to decrease pressure When the desired pressure is reached push knob in to lock in place Universal Quick Connect Body The universal quick connect body accepts the three most popular styles of quick connect plugs Industrial automotive Tru flate and ARO One hand push to connect operation makes connections simple and easy The two quick connect bodies allow the use of two tools at the same time Cooling System not shown This compressor contains an advanced 12 ENG design cooling system At the heart of this cooling system is an engineered fan It is perfectly normal for this fan to blow air through the vent holes in large amounts You know that the cooling system is working when air is being expelled Air Compressor Pump Compresses air into the air tank Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet Drain Valve The drain valve is locat ed at the base of the air tank and is used to drain condensation at the end of each use Check Valve When the air compres sor is operating the check valve is open allowing compressed air
9. mantenimiento programado de acuerdo a la necesidad Apagar la unidad colocando el inter ruptor en On Auto OFF en OFF Gire el regulador en sentido antiho rario y fije la presi n de salida en cero Extraiga la herramienta neum tica o el accesorio Tire del anillo de la v lvula de seguri dad permitiendo el purgado del aire del tanque hasta que la presi n del mismo llegue aproximadamente a 20 PSI Suelte el anillo de la v lvula de seguridad Drene el agua del tanque de aire abriendo la v lvula de drenaje ubica da en el fondo del tanque Riesgo de A ADVERTENCIA Explosi n El agua se condensa dentro del tanque de aire Si no se drena ella corroer debilitando la paredes del tanque de aire originando un riesgo de ruptura de sus paredes 7 Una vez que el agua haya sido drenada cierre la v lvula de drenaje NOTA Si la v lvula de drenaje estuviese enchufada libere toda la presi n de aire La v lvula podr ser extra da limpiada y luego reinstalada 8 Proteja el cable el ctrico y las mangueras de aire de da os tales como ser pisoteados o pasados por encima Enr llelos en forma floja alrededor de la manija del compresor Si estuviera equipado con ella 9 Almacene el compresor de aire en un sitio limpio y seco 42 SP GU A DE DIAGN STICO DE PROBLEMAS A ADVERTENCIA Riesgo de Operaci n Insegura La unidad arranca autom ticamente cuando est enchufada Al hacer el mantenimi
10. n del tanque disminuye por debajo del valor de la pre si n de conexi n regulada en f brica El motor se detendr cuando la presi n del tanque alcance los valores de presi n de corte regulado en f brica para su desconexi n V lvula de seguridad no mostrada Si el interruptor de presi n dejara de cortar el suministro de presi n del compresor conforme a los valores prefijados para la presi n de corte la v lvula de seguridad proteger contra la presi n elevada saltando de acuerdo a los valores prefi jados en f brica ligeramente superiores a los de presi n de corte de la llave inter ruptora Man metro para controlar la presi n de salida Este man metro indicar la pre si n de aire disponible a la salida del reg ulador Esta presi n est controlada por el regulador y es siempre menor o igual que la presi n del tanque D28071 Man metro de la presi n del tanque El man metro que controla la presi n del tanque indica la reserva de presi n del tanque de aire Regulador Controla la presi n de aire mostrada en el man metro de salida Tire de la perilla y g rela en sentido horario para incrementar la presi n y h galo en sentido inverso para disminuirla Cuando se logre la presi n deseada presione la perilla para bloquearla Cuerpo universal de conexi n r pida El cuerpo universal de conexi n r pida acepta los tres estilos m s comunes de conexi n universal industrial automotor Tru fl
11. protegido por fusibles use s lo fusibles de acci n retardada Los fusibles de acci n retardada deben estar marcados con la letra D en Canad y T en EE UU Si cualquiera de las condiciones enumer adas no pudiese ser cumplida o si el fun cionamiento del compresor causara reiter adas interrupciones de la energ a con la que se lo alimenta podr a ser necesario Operar al mismo desde un circuito de 20 A Para ello no ser necesario cambiar su cable de limentaci n D28071 OPERACI N Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci n de los distintos controles y regulaciones Conserve este manual para referencias futuras Interruptor On Auto Off Switch Man metro de presi n de salida Man metro Mg Interruptor de presi n de presi n Bomba de del tanque WE compresi n del aire Universal A Quick 5d Connect Y Bodies Regulador Descripci n de operaciones Familiaricese con estos controles antes de operar la unidad Interruptor On Auto Off Mueva este interruptor a la posici n ON para dar con tacto autom tico al interruptor de presi n y OFF para interrumpir la energ a el ctrica al t rmino del uso Interruptor de presi n El interruptor de presi n permite el arranque autom tico del motor cuando la presi
12. recept culo del ramal del circuito correc to Referirse al p rrafo Protecci n del voltaje y del circuito en la secci n Instalaci n de este manual 3 Abra completamente la v lvula de drena je sentido antihorario a fin de permitir la salida del aire e impedir el aumento de la presi n dentro del tanque de aire durante el periodo de asentamiento 4 Mueva la palanca On Auto Off a la posi ci n ON AUTO El compresor se pon dr en marcha 5 Haga funcionar el compresor durante 15 minutos Aseg rese de que la v lvula de drenaje est abierta y que la presi n de aire acumulado en el tanque sea m nima D28071 Luego de 15 minutos cierre la v lvula de drenaje sentido horario El aire recibido ir llenando hasta el punto de corte de presi n y el motor se detendr El compresor estar ahora listo para ser usado Antes de cada puesta en marcha dle D28071 Coloque el interruptor On Auto Off en la posici n OFF y cierre el regulador de aire Tire de la perilla del regulador gire en sentido antihorario hasta el l mite Empuje la perilla hasta su posici n blocante Conecte la manguera y accesorios NOTA Tanto la manguera como los 2 accesorios requerir n un enchufe de conexi n r pida si la salida del aire est equipada con un z calo de conexi n r p ida 38 SP A ADVERTENCIA Riesgo de Explosi n Demasiada presi n de aire podr ser la causa de riesgo de explosi n V
13. reduzca su presi n aproximadamente a 20 PSI Suelte el aro de la v lvula de seguridad 5 Drene el agua contenida en el tanque de aire abriendo la v lvula de drena je ubicada en la base del tanque en sentido contrario a las agujas de reloj D28071 Riesgo de Explosi n Dentro del tanque se producir condensaci n de agua Si no drena el agua lo cor roer y debilitar causando un riesgo de ruptura del tanque de aire 6 Una vez drenada el agua cierre la v lvula de drenaje girando en sentido horario Ahora el compresor de aire podr ser guardado NOTA Si la v lvula de drenaje fuera del tipo enchufe elimine toda la presi n de aire La v lvula podr entonces ser extra da limpiada y finalmente reinstalada Filtro de Aire Inspecci n y reempla zo Riesgo de que A ADVERTENCIA maduras Superficies calientes Las cabezas del com presor estan expuestas cuando se retira la cubierta del filtro Deje enfriar al compresor antes de darle servicio Riesgo de A PRECAUCI N Operaci n Lasegura Mantenga limpio el filtro de aire en todo momento No opere el compresor sin su filtro de aire Un filtro de aire sucio no permitira a la bomba compresora operar a su capaci dad m xima Antes de usar la bomba compresora verifique el filtro de aire para asegurarse que este limpio y en su sitio D28071 Si est sucio reempl celo por uno nuevo En algunos modelos el filtro puede ser removido po
14. Damaged regulator Regulator will Damaged regulator not shut off air outlet D28071 20 ENG CORRECTION If there is an excessive amount of pressure drop when the accessory is used adjust the regulator as instructed in the Operation section NOTE Adjust the regulated pressure under flow conditions while accessory is being used Operate safety valve manually by pulling on ring If valve still leaks it should be replaced Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor you need a larger compressor Check and replace if required Remove and clean or replace Tighten fittings Clean or replace air intake fil ter Do not operate the air compressor with the filter removed Refer to the Air Filter paragraph in the Maintenance section Clean or replace See Air Filter paragraph in the Maintenance section Have checked by a Trained Service Technician Have checked by a Trained Service Technician PROBLEM Motor will not run Knocking Noise Possible defect in safety Motor overload protection switch has tripped Tank pressure exceeds pressure switch cut in pressure Check valve stuck open Loose electrical connec tions Possible defective motor or starting capacitor Paint spray on internal motor parts Pressure release valve on pressure switch has not unloaded head pressu
15. Owner s Manual CRAFTSMAN Permanently Lubricated Single Stage Side Stack AIR COMPRESSOR Model No 919 167461 e Safety Guidelines e Assembly e Operation e Maintenance e Service and Adjustments e Troubleshooting e Repair Parts CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Roebuck and Co Hoffman Estates IL 60179 U S A Visit our Craftsman website www sears com craftsman D28071 Rev 2 8 15 03 TABLE OF CONTENTS WARRANTY 0 0 0000 ac id nd iaa eta a 2 SPECIFICATION CHART occcccccccc 3 SAFETY GUIDELINES DEFINITIONS 000 3 IMPORTANT SAFETY INSTRUCTIONS 0 3 8 GLOSSARY piain ooga rr ia dd ls de hed ed 9 ACCESSORIES 0 id a a oE AE 9 DUTY CYCLE ciaci n t e e ia 9 ASSEMBLY vincia do a Cee Sh aoa oe ae 10 INSTALLATION cenena el a Be ek Sale eh eee 10 11 OPERATION coojo diarias caida 12 14 MAINTENANCE ici it et da da 15 16 SERVICE AND ADJUSTMENTS 0 00 0000 17 STORAGE soos cece tan e eae ee aie 18 TROUBLESHOOTING GUIDE 0 000 19 21 REPAIR PAR S osc osa aii a 22 25 HOW TO ORDER REPAIR PARTS ccccoccoccc ro Back Cover WARRANTY FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or work manship within one year from the date of purchase Sears will at its option repair or replace it free of charge Contact y
16. S INSTRUCCIONES DE SEGURIDAD A ADVERTENCIA Algunos tipos de aserr n creados por m quinas el ctricas de lijado aserrado amolado perforado u otras actividades de la construcci n contienen materi ales qu micos conocidos en el Estado de California como causantes de c ncer defectos de nacimiento u otros da os del aparato reproductivo Algunos ejemplos de dichos productos qu micos son ta indica una situaci n potencialmente ries gosa la que si no es evitada podr a causa da os en la propiedada El plomo contenido en algunas pinturas con base de plomo e S lice cristalizado proveniente de los ladrillos el cemento y otros productos de alba iler a s Ars nico y cromo provenientes del tratamiento qu mico dado a la madera Su riesgo a dichas exposiciones variar dependiendo de la frecuencia con la que usted realice diferentes tipos de trabajo Para reducir su exposici n a la acci n de dichos agentes qu micos trabaje en zonas bien ventiladas y h galo con equipo de seguridad aprobado use siempre protecci n facial o respirador MSHA NIOSH aprobados cuando deba utilizar dichas herramientas Al utilizar herramientas neum ticas tambi n deben tomarse precauciones b sicas de seguridad a fin de reducir la posibilidad de riesgo de lesiones personales 27 SP D28071 INSTRUCCIONES IMPORTANTES DE SEGURIDAD D GUARDE ESTAS INSTRUCCIONES UA La operaci n o el mantenimiento inadecuados de este producto pod
17. ad protector will shut off the motor The motor must be allowed to cool down before restarting The compressor will automatically restart after the motor cools If the overload protector shuts the motor off frequently check for a pos sible voltage problem Low voltage can also be suspected when 1 The motor does not get up to full power or speed 2 Fuses blow out when starting the motor lights dim and remain dim when motor is started and is running 16 ENG SERVICE AND ADJUSTMENTS All maintenance and repair opera 4 Using an adjustable wrench tions not listed must be performed loosen pressure relief tube nut at by Trained Service Technician air tank and pressure switch Carefully move pressure relief AWARNING Risk of Unsafe tube away from check valve Operation Unit cycles automatically when power 5 Unscrew the check valve turn is on When servicing you may be counterclockwise using a 7 8 exposed to voltage sources com open end wrench Note the ori pressed air or moving parts entation for reassembly Before servicing unit unplug or dis 6 connect electrical supply to the air i compressor bleed tank of pres sure and allow the air compressor Using a screwdriver carefully push the valve disc up and down NOTE The valve disc to cool should move freely up and down on a spring which holds the valve To Replace or Clean Check disc in the closed position if not Valve the check valve needs to be
18. ado de cualquier pared u obstrucci n que restrinja el flujo de aire fresco a las aberturas de ventilaci n Opere el compresor en un sector limpio seco y bien ventilado No opere la unidad en espacios cerrados o cualquier rea confinada Mant ngase siempre alerta cada vez que el producto este funcionando Desconecte siempre el suministro el ctrico moviendo la palanca conmutadora de pre si n a la posici n de apagado off y drene el tanque diariamente o despu s de cada uso 28 SP PELIGRO ADVERTENCIA Riesgo de Explosi n Tanque de aire las siguientes condiciones podr an causar el debilitamiento del tanque y determinar su explosi n violenta da os a la propiedad o serias lesiones qu puede occurrir Drenaje inadecuado del agua condensada en el tanque siendo la causa del xido que reduce el espesor del tanque de acero Modificaciones o intento de reparaciones al tanque Modificaciones no autorizadas a la v lvula de descarga v lvula de seguridad o cualquier otro componente que controle la presi n del tanque La vibraci n excesiva puede debilitar el tanque de aire y causar su ruptura o explosi n AGREGADOS Y ACCESORIOS El exceso a los valores de presi n estable cidos para las herramientas neum ticas pis tolas rociadoras accesorios activados por aire cubiertas y otros objetos inflables puede causar su explosi n o ser arrojados pudien do ocasionar serias lesiones c mo pre
19. ador hacia partes del cuerpo a otras per sonas o animales Apague siempre el compresor y purgue la presi n de la manguera del aire y del tanque antes de intentar el mantenimiento el acople de herramientas o accesorios D28071 ADVERTENCIA Riesgo de Descarga El ctrica qu puede occurrir Su compresor de aire est accionado por elect ricidad Como cualquier otro dispositivo el ctri co impulsado el ctricamente si no se lo uti liza adecuadamente podr a causarle una descarga el ctrica Las reparaciones intentadas por personal no calificado podr an ocasionar serias lesiones o la muerte por electrocuci n CONEXI N A TIERRA Dejar de proveer una adecuada conexi n a tierra a este producto podr a ocasionar lesiones serias o la muerte por electrocuci n Ver instrucciones para la puesta a tierra ADVERTENCIA Riesgo de Inhalaci n qu puede occurrir El aire comprimido proveniente del compresor no es sano para respirar El chorro de aire puede contener mon xido de carbono vapores t xicos o part culas s lidas prove nientes del tanque La inhalaci n de dichos contaminantes puede llegar a causar serias lesiones o la muerte El rociado de materiales tales como pintura solventes removedores de pintura insectici das mata hierbas contienen emanaciones da inas y venenosas D28071 c mo prevenirlo Jam s opere el compresor a la intemperie cuan do est lloviendo o en condiciones de
20. an call anytime day or night or schedule a service appointment online Sears has over 12 000 professional repair specialists who have access to over 4 5 million quality parts and accessories That s the kind of professionalism you can count on to help prolong the life of your new purchase for years to come Purchase your Repair Protection Agreement today Some limitations and exclusions apply For prices and additional information call 1 800 827 6655 Sears Installation Service For Sears professional installation of home appliances garage door openers water heaters and other major home items in the U S A call 1 800 4 MY HOME 47 SP Contratos de Protecci n para Reparaciones Felicitaciones por hacer una compra inteligente Su nueva unidad Craftsman esta dise ada y fabricada para a os de operaci n confiable pero como todos los productos de calidad podr an requirir reparaciones de vez en cuando Ah es cuando el Contrato de Protecci n para Reparaciones le puede ahor rar dinero y molestias Compre ahora un Contrato de Protecci n para Reparaciones y prot jase contra apuros y gastos inesperados El contrato incluye lo siguiente Y Servicio Experto por uno de nuestros 12 000 profesionales especializados en reparaciones M Servicio ilimitado sin cargos por repuestos ni mano de obra por todas las reparaciones cubiertas M Reemplazo de la unidad si su unidad cubierta no puede repararse M Descuento d
21. ate y ARO La operaci n con una sola mano permite efectuar las conex iones en forma simple y sencilla Los cuerpos de los dos conectores r pidos permiten el uso de dos herramientas simult neamente Sistema de enfriamiento no mostrado Este compresor contiene un sistema de avanzada para el control de enfriamiento En el n cleo de este sistema de enfri amiento hay un ventilador especialmente dise ado Resulta perfectamente normal para este ventilador soplar aire en grandes cantidades a trav s de los orifi cios de ventilaci n De tal manera se podr saber que el sistema de enfriamien to trabaja cuando el aire esta siendo expelido 36 SP Bomba de compresi n del aire Comprime el aire dentro del tanque El aire de trabajo no se encuentra disponible hasta que el compresor haya alcanzado a llenar el tanque hasta un nivel de presi n por encima del requerido para la salida del aire V lvula de drenaje La v lvula de drenaje se encuentra ubicada sobre la base del tanque de aire y se usa para drenar la condensaci n al fin de cada uso V lvula reguladora DN V lvula de drenaje V lvula reguladora Cuando el compre sor de aire se encuentra funcionando la v lvula reguladora esta abierta permi tiendo la entrada del aire comprimido al tanque de aire Cuando el nivel de presi n del tanque alcanza el punto de corte la v lvula reguladora se cierra reteniendo la presi n del aire dentro del
22. e Presi n m xima de corte Cuando un compresor de aire se enciende y comien za a funcionar la presi n de aire en el tanque comienza a aumentar Aumenta hasta un valor de presi n alto fijado en f brica antes de que el motor autom tica mente se apague protegiendo a su tanque de aire de presiones m s altas que su capacidad La presi n alta a la cual el motor se apaga se llama presi n m xima de corte Ramal Circuito el ctrico que transporta electricidad desde el panel de control hasta el tomacorriente ACCESORIOS Esta unidad es suficiente para abastecer de energ a el ctrica a los siguientes accesorios Estos se encuentran disponibles a trav s del cat logo para herramientas el ctricas y manuales en cualquiera de los comercios que mantiene la l nea completa de SEARS Accesorios e Filtro de intercalar e Boquilla para inflar cubiertas e Juego de conexi n r pida varias medidas e Reguladores de presi n de aire e Lubricadores para niebla de aceite e Manguera de aire 1 4 3 8 o 1 2 DI en distintas longitudes Refi rase al grafico de selecci n ubicado sobre la unidad para elegir el tipo de her ramienta que esta unidad es capaz de hacer funcionar CICLO DE SERVICIO Esta bomba compresora de aire es capaz de funcionar continuamente sin embargo para prolongar la vida util de su compresor de aire se recomienda mantener un ciclo 33 SP promedio de servicio que oscile entre el 50 y el 75
23. el 10 en servicios y repuestos no cubiertos por este contrato Tambi n 10 de descuento del precio regular por cualquier inspecci n de man tenimiento preventivo M Asistencia telef nica r pida por personal t cnico de soporte de Sears para las unidades que requieran repararse en su domocilio en horarios convenientes para usted Una vez que usted compre su Contrato s lo necesita hacer una simple llamada telef nica para programar su servicio Puede llamar a cualquier hora en el d a o la noche o hacer lo por l nea v a internet Sears tiene m s de 12 000 profesionales especializados en reparaciones que tienen acceso a m s 4 5 millones de repuestos y accesorios de calidad Ese es el tipo de pro fesionalismo con el cual usted puede contar para ayudarle a prologar la vida til de su unidad durante todos los a os por venir Compre hoy su Contrato de Protecci n para Reparaciones Se aplican algunas limitaciones y exclu siones Para precios e informaci n adi cional llame al 1 800 827 6655 Servicio de Instalaciones de Sears Para instalaciones profesionales por Sears de artefactos para el hogar como abridores de puertas de garajes calentadores de agua y otros artefactos grandes del hogar en EE UU llame al 1 800 4 MY HOME D28071 Get it fixed at your home or ours Your Home For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter
24. ello significa que la bomba compresora no deberia trabajar mas de 30 a 45 minutos por hora D28071 ENSAMBLADO Desempaque 1 Extraiga la unidad de su caja y descarte todas las partes de embala je INSTALACI N C MO PREPARAR LA UNIDAD Ubicaci n del compresor de aire Ubique al compresor de aire en una zona limpia seca y bien ventilada La bomba del compresor de aire y su carcasa han sido dise adas para permitir un enfri amiento adecuado Las aberturas de ven tilaci n del compresor resultan entonces necesarias para el mantenimiento de una adecuada temperatura de funcionamiento No coloque g neros o contenedores encima ni en las proximidades de dichas aberturas INSTRUCCIONES PARA CONECTAR A TIERRA Riesgo de Descarga El ctrica Ante la even tualidad de un cortocircuito la conex i n a tierra reduce el riesgo de elec trocuci n proveyendo un conductor de escape para la corriente el ctrica Este compresor de aire debe estar ade cuadamente conectado a tierra El compresor port til de aire est equipa do con un cable que tiene un conductor destinado a tierra con una espiga apropiada para su conexi n ver las sigu ientes ilustraciones El enchufe debe ser utilizado con un toma corriente que haya sido instalado y conectado a tierra de acuerdo a todos los c digos y ordenan zas locales 1 El cable que acompa a a esta unidad tiene una espiga para conex i n a tierra Esta DEBE ser uti
25. en las partes internas del motor La v lvula de liberaci n de presi n en el interruptor de presi n no ha descargado la carga de presi n Fusible quemado disyuntor abierto Posible defecto en la v lvula de seguridad Posible defecto en la v lvula de seguridad 45 SP CORRECCI N Deje enfriar el motor y el interrup tor de sobrecarga se reajustar autom ticamente El motor arrancar autom ticamente cuando la presi n del tanque caiga por debajo de la presi n de corte m xima del interruptor de presi n Extraiga limpie o reemplace Compruebe la conexi n de cablea do dentro del interruptor de presi n y del rea de la caja de terminales Haga inspeccionar por un t cnico capacitado de servicio Haga inspeccionar por un t cnico capacitado de servicio No haga funcionar el compresor en el rea de pintura por rociado Vea la adverten cia acerca de vapores inflamables Purgue la l nea empujando la palan ca en el interruptor de presi n a la posici n off Apagado si la v lvula no se abre reemplace el interruptor 1 Inspeccione la caja de fusibles para determinar si hay fusibles quemados y reempl celos seg n sea necesario Reajuste el disyun tor No use un fusible o disyuntor con capacidad mayor que la especificada para su circuito especificado 2 Compruebe si el fusible es el correcto Debe usar un fusible de acci n retardada 3 Compruebe si existen condiciones de bajo
26. ento el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles Antes de intentar hacer repara ciones desconectar el compresor del tomacorriente drenar la presi n de aire del tanque y esperar a que el compresor se enfr e PROBLEMA CAUSA Presi n excesiva del tanque la v lvula de seguri dad se dispara Las conexiones pierden aire Hay fugas de aire en la v lvula de retenci n o dentro de ella P rdida de presi n Un interruptor de presi n de aire en el interruptor de la v lvula aliviadora P rdida de aire en el tanque de aire o en las sol daduras del tanque de aire P rdida de aire entre el cabezal y el plato de v lvula El interruptor de presi n no interrumpe al motor cuando el compresor alcanza la presi n de corte El interruptor de presi n de corte esta calibrado demasiado alto Las conexiones de los tubos no est n suficientemente ajustadas Compruebe si el asiento de la v lvula est da ado defectuoso libera la v lvula Tanque de aire defectuoso P rdida en el sellado 43 SP CORRECCI N Mueva la palanca On Auto Off a la posici n OFF si el equipo no corta contacte a un t cnico calificado para el servicio Contacte a un t cnico de servi cio calificado Ajuste las conexiones en las que el aire puede ser escuchado escap ndose Verifique las conexiones con soluci n jabonosa y agua NO SOBREA
27. erifique los valores de m xima presi n dados por el fabricante de las herramientas neum ticas y los accesorios La presi n de salida del reg ulador jam s debe exceder los valores de m xima presi n especificados C mo poner en marcha de Mueva la palanca On Auto Off a la posi ci n AUTO y deje que se incremente la presi n del tanque El motor se detendr una vez alcanzado el valor de presi n de corte del tanque Tire de la perilla del regulador y gire en sentido horario para incrementar la pre si n Cuando el valor deseado de presi n sea logrado presione la perilla hasta su posici n blocante El compresor estar listo para ser usado MANTENIMIENTO Responsabilidades del cliente erifique la v lvula de seguridad renaje del tanque Filtro de aire V lvulas de entrada y escape de la bomba del compresor de aire 1 M s frecuente en condiciones polvorientas o h medas Riesgo de Operaci n Insegura La unidad arranca autom ti camente cuando est enchufada Al hacer el mantenimiento el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles Antes de intentar hacer reparaciones desconectar el compresor del tomacorriente drenar la presi n de aire del tanque y esperar a que el compresor se enfr e Para asegurar una operaci n eficiente y una vida til m s prolongada del compre sor de aire debe prepararse y seguirse un programa de mantenimiento de rut
28. es are available through the current Power and Hand Tool Catalog or full line Sears stores Accessories e In Line Filter e Tire Air Chuck e Quick Connector Sets various sizes e Air Pressure Regulators e Oil Fog Lubricators e Air Hose 1 4 3 8 or 1 2 1 D in various lengths Refer to the selection chart located on the unit to select the tools this unit is capable of powering DUTY CYCLE This air compressor pump is capable of running continuously However to prolong the life of your air compres sor it is recommended that a 50 75 average duty cycle be 9 ENG maintained that is the air compres sor pump should not run more than 30 45 minutes in any given hour D28071 ASSEMBLY Unpacking 1 Remove unit from carton and discard all packaging INSTALLATION HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean dry and well ventilated area The air compressor should be located at least 12 away from the wall or other obstructions that will interfere with the flow of air The air compressor pump and shroud are designed to allow for proper cooling The ventila tion openings on the compressor are necessary to maintain proper operat ing temperature Do not place rags or other containers on or near these openings GROUNDING INSTRUCTIONS Risk of Electrical APANGER Shock In the event of a short circuit grounding reduces the risk of shock by pro
29. g Water will con dense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture and possible serious personal injury 7 After the water has been drained close the drain or drain valve NOTE If drain valve is plugged release all air pressure The valve can then be removed cleaned and reinstalled 8 Protect the electrical cord and air hose from damage such as being stepped on or run over Wind them loosely around the compressor handle If so equipped 9 Store the air compressor in a clean and dry location 18 ENG TROUBLESHOOTING AWARNING Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to volt age sources compressed air or moving parts Before servicing unit unplug or disconnect electrical supply to the air compressor bleed tank of pressure and allow the air compressor to cool PROBLEM Excessive tank pressure safe ty valve pops off Air leaks at fittings Air leaks at or inside check valve Air leaks at pressure switch release valve if equipped Air leaks in air tank or at air tank welds Air leaks between head and valve plate CAUSE Pressure switch does not shut off motor when com pressor reaches cut out pressure Pressure switch cut out too high Tube fittings are not tight enough Check valve seat damaged Defective pressure switch relea
30. he Installation section of this manu al 3 Open the drain valve fully count er clockwise to permit air to escape and prevent air pressure build up in the air tank during the break in period 4 Move the On Auto Off lever to ON AUTO position The com pressor will start D28071 5 Run the compressor for 15 min utes Make sure the drain valve is open and there is minimal air pressure build up in tank 6 After 15 minutes close the drain valve clockwise The air receiver will fill to cut out pressure and the motor will stop The compressor is now ready for use Before Each Start Up 1 Place On Auto Off lever to OFF 2 Pull regulator knob out turn counter clockwise until it stops Push knob in to lock in place 3 Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect D28071 MENNA Risk of Bursting Too much air pressure causes a hazardous risk of bursting Check the manufactur er s maximum pressure rating for air tools and accessories The reg ulator outlet pressure must never exceed the maximum pressure rating How to Start 1 Turn the On Auto Off lever to AUTO and allow tank pressure to build Motor will stop when tank pressure reaches cut out pressure 2 Pull the regulator knob out and turn clockwise to increase pres sure When the desired pressure is reached push knob in to lock
31. hich if not avoided could result in indicates a potentially hazardous situ death or serious injury ation which if not avoided may result in property damage IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE READ AND UNDERSTAND ALL WARN INGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT AWARNING Some dust created by power sanding sawing grinding drilling and other con struction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are gt lead from lead based paints e crystalline silica from bricks and cement and other masonry products ial arsenic and chromium from chemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment always wear MSHA NIOSH approved properly fitting face mask or respirator when using such tools When using air tools basic safety precautions should always be followed to reduce the risk of of per sonal injury 3 ENG D28071 IMPORTANT SAFETY INSTRUCTIONS Save these instructions 9 Improper operation or maintenance of this product could result in serious injury and property damage Read a
32. humedad Nunca opere el compresor sin sus defensas o sus cubiertas removidas o da adas Cualquier conexi n el ctrica o reparaci n requerida por este producto debe ser efectua da por personal autorizado de los servicen tros de acuerdo a los c digos el ctricos nacionales y locales Aseg rese que el circuito el ctrico al cual est conectado el compresor suministra apropiada conexi n a tierra tensi n correcta y una adecuada protecci n de fusibles c mo prevenirlo El aire obtenido directamente del compresor jam s deber ser utilizado para proveer aire para consumo humano Para poder utilizar el aire producido por este compresor y hacerlo respirable deber n instalarse un filtro adecua do y un equipo de seguridad intercalado Los filtros intercalados tanto como el equipo de seguridad utilizado en conjunto con el compre sor deber n ser capaces de procesar el tratamiento del aire de acuerdo a todos los c digos locales y federales previo al con sumo humano Trabaje en un rea con buena ventilaci n cruzada Lea y siga las instrucciones de seguridad provistas en el r tulo o en los datos de las hojas de seguridad del material que est pulverizando Use el respirador aprobado NIOSH MSHA designado para utilizarse con su aplicaci n espec fica 30 SP ADVERTENCIA Riesgo de Quemaduras qu puede occurrir Tocar el metal expuesto tal como el cabezal del compresor o los tubos de salida del e
33. ina El siguiente programa de mantenimiento de rutina est dise ado para un equipo funcio nando diariamente en un ambiente normal de trabajo Si fuese necesario el progra ma debe ser modificado para adaptarse a las condiciones bajo las cuales se usa su compresor Las modificaciones depen der n de las horas de operaci n y del ambiente de trabajo Los equipos de com presi n funcionando en un ambiente sumamente sucio y hostil requerir n mayor frecuencia de todas las verifica ciones de mantenimiento NOTA Vea en la secci n Operaci n la Ubicaci n de los controles 39 SP C mo verificar la v lvula de seguri dad Riesgo de Explosi n Si la v lvula de seguridad no trabaja ade cuadamente ello podr determinar la sobrepresi n del tanque creando el riesgo de su ruptura o explosi n 1 Antes de poner en marcha el motor tire del anillo de la valvula de seguri dad para confirmar la seguridad de que la misma opera libremente si la valvula quedase trabada o no traba jara c modamente deber ser reem plazada por el mismo tipo de v lvula C mo drenar el tanque Coloque la palanca On Auto Off en la posici n OFF 2 Tire de la perilla del regulador y gire en sentido contrario a las agujas de relo para establecer la salida de pre si n en cero 3 Remueva la herramienta neum tica o el accesorio 4 Tire del aro de la v lvula de seguri dad dejando purgar el aire del tanque hasta que este
34. izar un cable de extensi n el ctrica incremente el alcance de la manguera de aire dentro de la zona de trabajo a adi ndole otro largo de manguera a su extremo Conecte los largos adicionales de manguera de acuerdo a su necesidad Si no obstante debe utilizarse una extensi n de cable aseg rese de que La extensi n el ctrica de 3 conduc tores tenga un enchufe de conexi n a tierra de 3 hojas y que exista un recept culo que acepte el enchufe del producto Est en buenas condiciones No m s largo que 15 2 m 50 pies e Calibre 12 AWG o mayor La medida de los cables se incrementa a medida que su n mero ordinal decrece 10 y 8 AWG pueden ser usados tambi n NO USE 14 NI 16 AWG 35 SP Protecci n del voltaje y del circuito Acerca del voltaje y la m nima cantidad de circuitos requeridos refi rase al cuadro de especificaciones A Riesgo de MAPRECAUCI N Operaci n Lasegura Ciertos compresores de aire pueden ser operados en un circuito de 15 A siempre que se cumplan las sigu ientes condiciones 1 Que el voltaje suministrado a trav s de los ramales del circuito sea de 15 A 2 Que el circuito no sea utilizado para alimentar ninguna otra necesidad el ctrica 3 Que los cables de extensi n cum plan con las especificaciones 4 El circuito cuenta con un disyuntor de 15 amperios o un fusible de acci n retardada de 15 amperios NOTA Si el compresor est conec tado a un circuito
35. label or safety data sheets for the materials you are spray ing Use a NIOSH MSHA approved res pirator designed for use with your specific application 6 ENG HAZARD WARNING Risk of Burns ICA What Could Happen How To Prevent It Never touch any exposed metal parts on compressor during or immediately after operation Compressor will remain hot for several minutes after operation Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool Touching exposed metal such as the compressor head or outlet tubes can result in serious burns WARNING Risk from Moving Parts AS Yay What Could Happen Moving parts such as the pulley flywheel and belt can cause serious injury if they come into contact with you or your cloth ing Attempting to operate compressor with damaged or missing parts or attempting to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious injury How To Prevent It Never operate the compressor with guards or covers which are damaged or removed Any repairs required on this product should be performed by authorized service center personnel HAZARD WARNING Risk of Falling What Could Happen How To Prevent It A portable compressor can fall from a table workbench or roof causing dam age to the compressor and could resul
36. lizada con un tomacorriente conectado a tierra D28071 IMPORTANTE El tomacorriente que ser utilizado deber haber sido conectado a tierra conforme a todos los c digos locales y ordenanzas 2 Aseg rese de que el tomacorriente que ser utilizado tenga la misma configu raci n que el enchufe de conexi n a tier ra NO UTILICE UN ADAPTADOR Ver figura Enchufe y Z meso conectados a Perno de conexi n a tierra 3 Inspeccione el enchufe y su cord n antes de cada uso No use si existieran signos de da os 4 Si las instrucciones de conexi n a tierra no fueran completamente comprendi das o si se estuviera ante la duda acer Ca de que el compresor estuviese ade cuadamente conectado a tierra haga verificar la instalaci n por un elec tricista competente Riesgo de Descarga El ctrica La conexi n inadecuada a tierra puede determinar una descarga el ctrica No modifique el enchufe provisto Si el mismo no penetrara el tomacorriente disponible un electricista competente deber instalar uno apropiado La reparaci n del cable o del enchufe DEBER ser efectuada por un elec tricista competente 34 SP Cables de extensi n el ctrica No se recomienda la utilizaci n de cables de extensi n el ctrica El uso de cables de extensi n el ctrica originar una ca da de tensi n lo que determinar una p rdi da de potencia del motor as como su recalentamiento En lugar de util
37. nd understand all warnings and operation instructions before using this equipment HAZARD WARNING Risk of explosion or fire What Could Happen It is normal for electrical contacts with in the motor and pressure switch to spark If electrical sparks from compressor come into contact with flammable vapors they may ignite causing fire or explosion Restricting any of the compressor ven tilation openings will cause serious over heating and could cause fire Unattended operation of this product could result in personal injury or prop erty damage To reduce the risk of fire do not allow the compressor to operate unattended D28071 W Ml How To Prevent It Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent vapors If spraying flammable materials locate compressor at least 20 feet away from spray area An additional length of hose may be required Store flammable materials in a secure location away from compressor Never place objects against or on top of compressor Operate compressor in an open area at least 12 inches away from any wall or obstruction that would restrict the flow of fresh air to the ventila tion openings Operate compressor in a clean dry well ventilated area Do not operate unit indoors or in any confined area Always remain in attendance with the product when it is operating Always disconnect electrical
38. o Jam s altere los elementos de seguridad de este producto Equipe la zona de operaciones con un extin guidor de fuego No opere la m quina si sta tiene partes faltantes rotas o no autorizadas CONSERVAR ESTAS INSTRUCCIONES D28071 32 SP GLOSARIO Familiar cese con los siguientes t rminos antes de operar la unidad CFM Cubic feet per minute Pies c bicos por minuto SCFM Stardard cubic feet per minute Pies c bicos est ndar por minuto una unidad de medida que permite medir la cantidad de entrega de aire PSIG Pound per square inch Libras por pulgada cuadrada ASME American Society of Mechanical Engineers Sociedad Americana de Ingenieros Mec nicos hecho probado inspeccionado y registrado en cumplim iento de los est ndares de la ASME C digo de certificaci n Los productos que usan una o m s de las siguientes marcas UL CUL ETL CETL han sido evaluados por OSHA laboratorios inde pendientes certificados en seguridad y re nen los est ndares suscriptos por los laboratorios dedicados a la certificaci n de la seguridad Presi n m nima de corte Cuando el motor est apagado la presi n del tanque de aire baja a medida que usted contin a usando su accesorio Cuando la presi n del tanque baja al valor fijado en f brica como punto bajo el motor volver a arrancar autom ticamente La presi n baja a la cual el motor arranca autom ti camente se llama presi n m nima de cort
39. our nearest Sears Service Center 1 800 4 MY HOMES to arrange for repair or return the Air Compressor to the place of purchase for replacement If this Air Compressor is used for commercial or rental purposes this warranty applies for only ninety days from the date of purchase This warranty gives you specific legal rights and you may have other rights which vary from state to state Sears Roebuck and Co Dept 817WA Hoffman Estates IL 60179 D28071 2 ENG SPECIFICATION CHART Model No 919 167461 Max Developed HP 3 Bore 2 375 Stroke 1 35 Voltage Single Phase 120V Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Gallons 4 Approximate Cut in Pressure 120 Approximate Cut out Pressure 150 SCFM 40 psig 7 9 SCFM 90 psig 5 5 SAFETY GUIDELINES DEFINITIONS This manual contains information that is important for you to know and understand This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS To help you rec ognize this information we use the symbols below Please read the manual and pay attention to these sections di dicates an imminent IN ey dicates a potentially ly hazardous situation hazardous situation which if not avoided will result in which if not avoided may result in death or serious injury minor or moderate injury IMG ice ndicates a potentially PIN felt Used without the hazardous situation safety alert symbol w
40. pere el compresor sobre un techo u otra posici n elevada Utilice mangueras adicionales de aire para alcanzar posiciones altas D28071 ADVERTENCIA Riesgo de Serias Lesiones o Da os a la Propiedad al Transportar el Compresor Fuego inhalaci n da o a la superficie de veh culos qu puede occurrir El aceite puede derramarse y ello podr a resultar en serias lesiones o la muerte debido al riesgo de incendio o inhalaci n El derrame de aceite da a alfombras pinturas u otras superficies de veh culos o remolques c mo prevenirlo Deposite el compresor sobre una alfombrilla protectora cuando lo transporte a fin de pro teger al veh culo de p rdidas por goteo Retire el compresor del veh culo inmediatamente despu s de su arribo al destino ADVERTENCIA Riesgo de Operaci n Lasegura qu puede occurrir La operacion insegura de su compresor de aire podr a ocasionarle serias lesiones o la muerte a usted u otros c mo prevenirlo Revise y comprenda todas las instrucciones y advertencias contenidas en este manual Familiaricese con los m todos de operaci n y control del compresor de aire Mantenga libre la zona de operaciones de per sona alguna animales dom sticos y obst culos Mantenga alejados a los ni os del compresor de aire en todo momento No opere el producto cuando se encuentre fatigado o bajo la influencia del alcohol o dro gas Est alerta en todo moment
41. power by moving pressure switch lever to the off position and drain tank daily or after each use 4 ENG HAZARD WARNING Risk of Bursting M Air Tank The following conditions could lead to a weakening of the tank and result in a violent tank explosion and could cause property damage or serious injury What Could Happen Failure to properly drain condensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure Excessive vibration can weaken the air tank and cause rupture or explosion ATTACHMENTS amp ACCESSORIES Exceeding the pressure rating of air tools spray guns air operated acces sories tires and other inflatables can cause them to explode or fly apart and could result in serious injury How To Prevent It Drain tank daily or after each use If tank develops a leak replace it immediately with a new tank or replace the entire com pressor Never drill into weld or make any modifi cations to the tank or its attachments The tank is designed to withstand specific operating pressures Never make adjust ments or parts substitutions to alter the factory set operating pressures For essential control of air pressure you must install a pressure regulator and pressure gauge to the air outlet if not equipped of
42. r an ocasionar serias lesiones y da os a la propiedad Lea y comprenda todas las advertencias e instrucciones de funcionamiento antes de utilizar este equipo PELIGRO ADVERTENCIA Riesgo de Explosion o Incendio qu puede occurrir Para los contactos el ctricos es normal la existencia de chispas entre el motor y el interruptor a presi n Si las chispas el ctricas provenientes del com presor tomaran contacto con emanaciones de materiales inflamables ellos podr an arder originando incendio o explosi n Restringir cualquiera de las aberturas de ven tilaci n causar un serio recalentamiento y podr a producir un incendio Dejar desatenido este producto mientras el mismo est en funcionamiento puede resul tar en lesiones personales o da os a la propiedad Para reducir el riesgo de incen dio no permita que el compresor opere desatendido D28071 c mo prevenirlo Opere siempre el compresor en un sector bien ventilado y libre de materiales com bustibles gasolina o emanaciones de sol vente En un rea de rociado de materiales inflam ables ubique al compresor por lo menos a 6 1m 20 pies de distancia del rea de rocia do Podr a requerirse una extensi n de la manguera Almacene los materiales inflamables en una ubicaci n segura alejados del compresor Jam s coloque objetos apoyados o sobre el compresor Opere el compresor en un sector abierto por lo menos a 30 cm 12 pulgadas alej
43. r medio de alicates de punta fina o un destornillador Tire o extraiga el viejo filtro y cuidadosamente limpie la zona del filtro Coloque un nuevo filtro V lvulas de entrada y escape de la bomba del compresor de aire Una vez al a o haga que un T cnico Capacitado de Servicio inspeccione las v lvulas de entrada y escape de la bomba del compresor de aire 40 SP SERVICIO Y AJUSTES Todo tipo de mantenimiento y opera ciones de reparaci n no mencionados deber n ser efectuados por personal t c nico especializado Riesgo de Operaci n Insegura La unidad arranca autom ti camente cuando est enchufada Al hacer el mantenimiento el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles Antes de intentar hacer reparaciones desconectar el compresor del tomacorriente drenar la presi n de aire del tanque y esperar a que el compresor se enfr e Para reemplazar o limpiar la v lvu la de retenci n 1 Libere toda la presi n del tanque de aire Vea C mo Drenar el Tanque en la secci n Mantenimiento 2 Coloque la palanca On Auto Off en la posici n OFF 3 Utilizando una llave regulable afloje la tuerca de salida del tubo del tanque de aire y la bomba Retire cuida dosamente la tuber a de sali da de la v lvula de retenci n regulador y 41 SP 4 Utilizando una llave regulable afloje el tubo aliviador de presi n del tanque de aire y el interrup
44. rds is not recom mended The use of extension cords will cause voltage to drop resulting in power loss to the motor and over heating Instead of using an extension cord increase the working reach of the air hose by attaching If an extension cord must be used be sure it is e a3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the product e in good condition e no longer than 50 feet e 12 gauge AWG or larger Wire size increases as gauge number decreases 10 AWG and 8 AWG may also be used DO NOT USE 14 OR 16 AWG 11 ENG Voltage and Circuit Protection Refer to the Parts Manual for the volt age and minimum branch circuit requirements Risk of Unsafe ae AN Operation Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other electrical needs 3 Extension cords comply with specifications 4 Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse NOTE If com pressor is connected to a circuit protected by fuses use only time delay fuses Time delay fuses should be marked D in Canada and T in the US If any of the above conditions cannot be met or if operation of the com pressor repeatedly causes interrup tion of the power it may be neces
45. re Fuse blown circuit breaker tripped valve Defective check valve 21 ENG CORRECTION Let motor cool off and over load switch will automatically reset Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Remove and clean or replace Check wiring connection inside pressure switch and ter minal box area Have checked by a Trained Service Technician Have checked by a Trained Service Technician Do not operate the compressor in the paint spray area See flamma ble vapor warning Bleed the line by pushing the lever on the pressure switch to the off position if the valve does not open replace switch 1 Check fuse box for blown fuse and replace as nec essary Reset circuit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particu lar branch circuit Check for proper fuse You should use a time delay fuse Check for low voltage conditions and or proper extension cord Disconnect the other elec trical appliances from cir cuit or operate the com pressor on its own branch circuit Operate safety valve manually by pulling on ring If valve still leaks it should be replaced Remove and clean or replace D28071 CONTENIDO GARANT A oorner Se ie eda San aden tad 26 CUADRO DE ESPECIFICACIONES 00c ccc eee cece sees 27 DEFINICIONES DE NORMAS DE SEGURIDAD
46. ros noventa d as a partir de su fecha de compra Esta garant a le otorga derechos espec ficos y usted podr a tener otros dere chos que var an de un estado a otro Sears Roebuck and Co Dept 817WA Hoffman Estates IL 60179 D28071 26 SP CUADRO DE ESPECIFICACIONES Modelo N M x HP desarrollado Di metro interior Carrera Tensi n monof sica Circuito m nimo requerido Tipo de fusible Acci n retardada Capacidad de aire en el tanque Presi n de corte de entrada Presi n de corte de salida 919 167461 3 2 875 47 6 mm 1 35 31 8 mm 120V 15A 4 Galones 22 7 litros 120 150 SCFM a 40 psig 7 9 Calibre de libras por pulgada cuadrada 5 5 Calibre de libras por pulgada cuadrada DEFINICIONES DE NORMAS DE SEGURIDAD SEGURIDAD Y PREVENCI N DE PROBLEMAS DEL EQUIPO Para ayudar al reconocimiento de esta informaci n hemos utilizado los s mbolos mostrados abajo S rvase leer el manual y prestar atenci n a dichas secciones APELIGRO Indica una situaci n de APRECAUCI N Indica una situaci n inminente riesgo la potencialmente cual si no es evitada causar la muerte peligrosa la cual si no es evitada podr a o lesiones serias resultar en lesiones menores o moder adas SCFM a 90 psig Indica una Usado sin el s mbolo PEL situaci n poten ABORTION de seguridad de aler cialmente riesgosa que si no es evita da podria resultar en la muerte o lesiones serias IMPORTANTE
47. sary to operate it from a 20 amp cir cuit It is not necessary to change the cord set D28071 OPERATION Know Your Air Compressor READ THIS OWNER S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments Save this manual for future reference Tank Pressure On Auto Off Switch Pressure Switch Air Compressor Universal A Quick FSA Connect YX Bodies Description of Operation Become familiar with these controls before operating the unit On Auto Off Switch Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use Pressure Switch The pressure switch automatically starts the motor when the air tank pressure drops below the factory set cut in pres sure It stops the motor when the air tank pressure reaches the factory set cut out pressure Safety Valve not shown If the pressure switch does not shut off the air compressor at its cut out pres sure setting the safety valve will pro tect against high pressure by pop ping out at its factory set pressure slightly higher than the pressure switch cut out setting Outlet Pressure Gauge The outlet pressure gauge indicates the air pres sure available at the outlet side of the D28071 regulator This pressure is controlled by the regulator
48. scape puede ocasionarle serias que maduras ADVERTENCIA Riesgo de Partes M viles qu puede occurrir Partes movibles tales como la polea el volante y la correa podr an ser la causa de serias lesiones si ellas entraran en contacto con usted o sus ropas Intentar operar el compresor con sus partes da adas o faltantes o la reparaci n del compresor con sus protecciones removidas puede exponerlo a usted a partes movibles que podr an resultar en lesiones serias ull como prevenirlo Jamas toque partes de metal expuestas en el compresor durante o inmediatamente despu s de la operaci n el compresor permanecer caliente por varios minutos luego de la operaci n No lo cubra con fundas protectoras o intente el mantenimiento hasta que la unidad haya alcanzado su enfriamiento c mo prevenirlo Nunca opere el compresor sin sus defensas o sus cubiertas removidas o da adas Cualquier reparaci n requerida por este pro ducto debe ser efectuada por personal autorizado de los servicentros ADVERTENCIA Riesgo de Ca da u puede occurrir Un compresor port til puede caerse de la mesa el banco de trabajo o del techo da ando al compresor y pudiendo resultar en serias lesiones o la muerte del operador 31 SP c mo prevenirlo Opere siempre el compresor en una posici n estable y segura a fin de prevenir el movimien to accidental de la unidad Jam s o
49. se valve Defective air tank Leaking seal 19 ENG CORRECTION Move On Auto Off lever to the OFF position if the unit does not shut off contact a Trained Service Technician Contact a Trained Service Technician Tighten fittings where air can be heard escaping Check fittings with soapy water solution DO NOT OVER TIGHTEN A defective check valve results in a constant air leak at the pressure release valve when there is pressure in the tank and the compressor is shut off Replace check valve Refer the To Replace or Clean Check Valve in the Service and Adjustment section Contact a Trained Service Technician Air tank must be replaced Do not repair the leak POG Risk of Bursting Do not drill into weld or otherwise modify air tank or it will weaken The tank can rupture or explode Contact a Trained Service Technician D28071 PROBLEM CAUSE Pressure reading t is normal for some on the regulated pressure drop to occur pressure gauge if equipped drops when an accessory is used Air leak from safety valve Possible defect in safety valve Prolonged excessive use of air Compressor is not large enough for air requirement Compressor is not supplying enough air to operate acces sories Hole in hose Check valve restricted Air leaks Restricted air intake filter Restricted air intake Dirty air filter Regulator knob has continuous air leak
50. t in serious injury or death to the operator Always operate compressor in a stable secure position to prevent accidental movement of the unit Never operate compressor on a roof or other elevated position Use additional air hose to reach high locations 7 ENG D28071 HAZARD WARNING Risk of Serious Injury or Property Damage When A gt Transporting Compressor Fire Inhalation Damage to Vehicle Surfaces What Could Happen How To Prevent It Always place COMPRESSOR on a pro tective mat when transporting to protect against damage to vehicle from leaks Remove COMPRESSOR from vehicle immediately upon arrival at your destina tion Oil can leak or spill and could result in fire or breathing hazard serious injury or death can result oil leaks will damage carpet paint or other surfaces in vehi cles or trailers HAZARD WARNING Risk of Unsafe Operation A What Could Happen How To Prevent It Unsafe operation of your air compressor could lead to serious injury or death to you or others Review and understand all instructions and warnings in this manual Become familiar with the operation and controls of the air compressor Keep operating area clear of all persons pets and obstacles Keep children away from the air compres sor at all times Do not operate the product when fatigued or under the influence of alco hol or drugs Stay alert at all times Never defeat the safety fea
51. t is raining or in wet conditions Never operate compressor with protec tive covers removed or damaged Any electrical wiring or repairs required on this product should be performed by authorized service center personnel in accordance with national and local electri cal codes Make certain that the electrical circuit to which the compressor is connected pro vides proper electrical grounding cor rect voltage and adequate fuse protec tion HAZARD WARNING Risk to Breathing What Could Happen The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid parti cles from the tank Breathing these contaminants can cause serious injury or death Sprayed materials such as paint paint solvents paint remover insecticides weed killers may contain harmful vapors and poisons D28071 How To Prevent It Air obtained directly from the compressor should never be used to supply air for human consumption In order to use air produced by this compressor for breath ing suitable filters and in line safety equipment must be properly installed In line filters and safety equipment used in conjunction with the compressor must be capable of treating air to all applica ble local and federal codes prior to human consumption Work in an area with good cross ventila tion Read and follow the safety instruc tions provided on the
52. tanque V lvula aliviadora de presi n La v lvula aliviadora de presi n se encuentra ubica da en el costado del interruptor de pre si n ha sido dise ada para liberar autom ticamente el aire comprimido de la cabeza compresora y el tubo de salida cuando el compresor de aire alcanza la presi n de corte o es apagado La v lvula aliviadora de presi n permite el arranque libre del motor Cuando el motor se detiene deber a escucharse el escape del aire a trav s de dicha v lvula durante unos segundos No debe escucharse escape alguno mientras el motor est en marcha ni p rdidas continuas una vez que se alcanz la presi n de corte 37 SP V lvula aliviadora de presi n C mo utilizar su unidad C mo detenerla 1 Coloque la posici n de la llave inter ruptora On Auto Off en la posici n OFF Antes de poner en marcha Procedimiento para el asentamiento Riesgo de A ADVERTENCIA Operaci n Insegura Si las siguientes instrucciones no fuesen seguidas estrictamente podr n ocurrir serios da os Este procedimiento es necesario antes de poner en servicio al compresor de aire y cuando la v lvula regu ladora o la bomba completa del compresor haya sido reemplazada 1 Aseg rese que la palanca On Auto Off est en la posici n OFF NOTA Tire del acoplamiento hacia atr s hasta percibir el clic que impide el escape del aire de la conexi n r pida 2 Enchufe el cable de alimentaci n en el
53. to enter the air tank When the air com pressor reaches cut out pressure the check valve closes allowing air pressure to remain inside the air tank Pressure Release Valve The pres sure release valve located on the side of the pressure switch is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches cut out pressure or is shut off The pressure release valve allows the motor to restart freely When the motor stops running air will be heard escaping from this valve for a few seconds No air should be heard leaking when the motor is running or continuous leaking after unit reaches cut out pressure 13 ENG Pressure Release Valve How to Use Your Unit How to Stop 1 Set the On Auto Off lever to OFF Before Starting Break in instructions AWARNING Risk of Unsafe Operation Serious damage may result if the fol lowing break in instructions are not closely followed This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced 1 Make sure the On Auto Off lever is in the OFF position NOTE If quick connect is installed pull coupler back until it clicks to pre vent air from escaping through the quick connect 2 Plug the power cord into the cor rect branch circuit receptacle Refer to Voltage and Circuit Protection paragraph in t
54. tor de presi n Retire cuidadosamente la tuber a de alivio de presi n de la v lvula de retenci n 5 Desenrosque la v lvula de retenci n gir ndola hacia la izquierda usando una llave de boca de 7 8 Tome nota de la orientaci n para volverla a ensamblar 6 Usando un destornillador empuje con cuidado el disco de la v lvula hacia arriba y hacia abajo NOTA El disco de la v lvula debe moverse libremente hacia arriba y hacia abajo sobre un resorte que detiene el disco de la v lvula en la posici n cerrada Si no lo hace la v lvula de retenci n necesita ser limpiada o reemplazada Destornillador En posici n abierta nada es visible En posici n cerrada el disco es visible Limpie o reemplace la v lvula de retenci n Un solvente tal como un removedor de pintura o de barniz puede usarse para limpiar la v lvula de retenci n 8 Aplique sellador a las roscas de la v lvula de retenci n Vuelva a insta lar la v lvula de retenci n gire a la derecha 9 Vuelva a instalar la tuber a de alivio de presi n Ajuste las tuercas 10 Vuelva a instalar la tuber a de salida y ajuste las tuercas 11 Ejecute el procedimiento de puesta en marcha Vea Procedimiento de Puesta en Marcha en la secci n Operaci n D28071 ALMACENAJE Antes de guardar su compresor de aire aseg rese de hacer lo siguiente 1 D28071 Revise la secci n Mantenimiento de las p ginas precedentes y ejecute el
55. tures of this product Equip area of operation with a fire extin guisher Do not operate machine with missing broken or unauthorized parts SAVE THESE INSTRUCTIONS D28071 8 ENG GLOSSARY Become familiar with these terms before operating the unit CFM Cubic feet per minute SCFM Standard cubic feet per minute a unit of measure of air deliv ery PSIG Pounds per square inch gauge a unit of measure of pressure Code Certification Products that bear one or more of the following marks UL CUL ETL CETL have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety Cut In Pressure While the motor is off air tank pressure drops as you continue to use your accessory When the tank pressure drops to a certain low level the motor will restart automatically The low pressure at which the motor automatically restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor auto matically shuts off protecting your air tank from pressure higher than its capacity The high pressure at which the motor shuts off is called cut out pressure Branch Circuit Circuit carrying elec tricity from electrical panel to outlet This unit is capable of powering the following Accessories The accessori
56. venirlo Drene el tanque diariamente o despu s de cada uso Si el tanque genera una p rdida reempl celo inmediatamente con un nuevo tanque o reemplace el compresor completo Jam s perfore suelde o efect e modificaci n alguna al tanque o sus accesorios El tanque est dise ado para resistir presiones operativas espec ficas Jam s efect e ajustes o sustituya partes que alteren las regula ciones de presi n originales de f brica Para un control esencial de la presi n debe usted instalar un regulador y un medidor de presi n a la salida del aire de su compresor Si no estuviese equipado Siga las recomenda ciones de los fabricantes de su equipo y jam s exceda los valores m ximos de presi n permiti dos para los accesorios Jam s use el compre sor para inflar objetos que requieren poca o baja presi n tales como juguetes para los ni os pelotas de f tbol pelotas de basquet etc PELIGRO ADVERTENCIA Riesgo de Objetos Arrojados por el Aire qu puede occurrir El chorro de aire comprimido puede causar da os sobre los tejidos blandos de la piel expuesta y puede propulsar suciedad astil las part culas sueltas y peque os objetos a alta velocidad ocasionando da os a la propiedad o lesiones personales 29 SP c mo prevenirlo Al utilizar el compresor use siempre anteojos de seguridad ANSI Z87 1 aprobados con protecci n lateral Jam s apunte ninguna boquilla o pulver iz
57. voltaje y o si el cord n de extensi n es el correcto 4 Desconecte todos los otros artefactos el ctricos del cir cuito u opere el compresor en su propio circuito Opere la v lvula de seguridad man ualmente tirando de su anillo Si la v lvula aun pierde deber ser reemplazada Extraiga limpie o reemplace D28071 NOTES NOTAS D28071 46 SP Repair Protection Agreements Congratulations on making a smart pur chase Your new Craftsman product is designed and manufactured for years of dependable operation But like all prod ucts it may require repair from time to time That s when having a Repair Protection Agreement can save you money and aggravation Purchase a Repair Protection Agreement now and protect yourself from unexpected hassle and expense Here s what s included in the Agreement M Expert service by our 12 000 profes sional repair specialists M Unlimited service and no charge for parts and labor on all covered repairs M Product replacement if your covered product can t be fixed M Discount of 10 from regular price of service and service related parts not covered by the agreement also 10 off regular price of preventive mainte nance check M Fast help by phone phone support from a Sears technician on products requiring in home repair plus conven ient repair scheduling Once you purchase the Agreement a sim ple phone call is all that it takes for you to schedule service You c
58. who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME Anytime day or night 1 800 469 4663 U S A and Canada www sears com www sears ca Our Home For repair of carry in products like vacuums lawn equipment and electronics call or go on line for the nearest Sears Parts and Repair Center 1 800 488 1222 Anytime day or night U S A only www sears com To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparaci n Au Canada pour service en francais a domicilio y para ordenar piezas 1 800 LE FOYER 1 888 SU HOGAR 1 800 533 6937 1 888 784 6427 www sears ca SEARS Sears Roebuck and Co Registered Trademark Trademark S Service Mark of Sears Roebuck and Co Marca Registrada Marca de F brica SM Marca de Servicio de Sears Roebuck and Co MC Marque de commerce MP Marque d pos e de Sears Roebuck and Co
59. your compressor Follow the equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments Never use compressor to inflate small low pres sure objects such as children s toys footballs basketballs etc HAZARD WARNING Risk from Flying Objects What Could Happen The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt chips loose particles and small objects at high speed result ing in property damage or personal injury 5 ENG How To Prevent It Always wear ANSI Z87 1 approved safety glasses with side shields when using the compressor Never point any nozzle or sprayer toward any part of the body or at other people or animals Always turn the compressor off and bleed pressure from the air hose and tank before attempting maintenance attaching tools or accessories D28071 HAZARD WARNING Risk of Electrical Shock What Could Happen Your air compressor is powered by electricity Like any other electrically powered device If it is not used prop erly it may cause electric shock Repairs attempted by unqualified per sonnel can result in serious injury or death by electrocution Electrical Grounding Failure to provide adequate grounding to this product could result in serious injury or death from electrocution See grounding instructions How To Prevent It Never operate the compressor outdoors when i

Download Pdf Manuals

image

Related Search

Related Contents

Prime-Line D 1509 Instructions / Assembly  Attix5 Pro Server Edition User Manual  Installation Information  Guide de dépannage pour les clients  Harbor Freight Tools 50 Ft. Commercial Power_Feed Drain Cleaner with GFCI Product manual  Philips 170V7FB/27B Getting Started Guide  User Manual Snapshot  Gateway AR-230 DVD Recorder  Color Rear Video Projector    