Home
Connect Tech BlueStorm Universal PCI Electronic Accessory User Manual
Contents
1. 6 Kbps RS 232 and 1 8432 Mbps RS 422 485 using PCI UARTs with 64 bytes of TxD RxD FIFO buffers Support for three RS 422 485 modes full duplex half duplex and multi drop slave Each port can be configured independently baud rate parity data and stop bits DB 9 male fan out cable custom cable solutions also offered Six RJ 11 connectors provide 12 VDC or 5 VDC output on pin 6 with a current limit of 300 mA BlueStorm SP RJ 11 model only Optional multi strike surge suppression on all signals all ports select models only PCI compliant with Plug and Play installation QNX 4 X 6 X Windows 2000 CE NT XP XPe XP 64 Bit Server 2003 Server 2003 64 Bit Vista VxWorks Ardence RTX and Linux compatible contact Connect Tech for most current list Your BlueStorm product consists of the following components A BlueStorm adapter An additional low standard height chassis bracket available on LP models only One of the following DB 9 fan out cable approximately 12 in 30 5 cm long a DB 9 external I O box approximately 4ft 122 cm long or a DB 25 fan out cable approximately 12in 30 cm long optional BlueStorm device drivers and documentation CD Revision 0 10 BlueStorm Installation Guide Connect Tech Inc BlueStorm Installation Overview There are three stages to installing your BlueStorm card 1 Hardware Configuration Interrupts and Memory selection will be set by the host computer s BIOS and operating system Thi
2. Jx1 Jx2 Jx3 Jx4 Jx5 Jx6 4 x RJ 45 P5 JA z Port 1 EH JB Port 2 JC z Port 3 JD Port 4 Figure 5 BlueStorm SP Opto Jumper Block Locations 4 Port Models 10 Revision 0 10 BlueStorm Installation Guide Connect Tech Inc 6 x RJ 11 P4 J e e e 2 Figure 6 BlueStorm SP RJ 11 8 Port Model Note Refer to Table 8 for port 7 and port 8 pinouts Jumper Configuration for BlueStorm Jumper configuration options will vary by model BlueStorm LP RS 422 485 cards feature the jumper layout listed in Figure 7 while BlueStorm SP and BlueStorm SP Opto cards use the jumper layout in Figure 8 Lastly BlueStorm SP RJ 11 uses the jumper layout used in Figure 9 BlueStorm ports and cards that communicate only in RS 232 modes do not have jumper blocks installed Figure 7 demonstrates a common set of jumper configurations for a BlueStorm LP RS 422 485 card BlueStorm LP RS 232 ports do not require jumper configuration The four RS 422 485 ports are set as follows Port 1 is set for half duplex Port 2 is set for half duplex Port 3 is set for full duplex and Port 4 is set for multi drop slave Figure 8 indicates a common set of jumper configurations for BlueStorm SP and BlueStorm SP Opto The four ports are set as follows Port 1 is set for RS 232 Port 2 is set for half duplex Port 3 is set for full duplex and Port 4 is set for multi drop slave Revision 0 10 11 12 BlueStorm Installation Guide Connect
3. Overview If you experience difficulties after reading the manual and or using the product contact the Connect Tech Inc reseller from which you purchased the product In most cases the reseller can help you with product installation and difficulties In the event that the reseller is unable to resolve your problem our highly qualified support staff can assist you Our support section is available 24 hours a day 7 days a week on our website at www connecttech com sub support support asp See the contact information section below for more information on how to contact us directly Our technical support is always free Contact Information We offer three ways for you to contact us Mail Courier You may contact us by letter at Connect Tech Inc Technical Support 42 Arrow Road Guelph Ontario Canada N1K 1S6 Email Internet You may contact us through the Internet Our email and URL addresses on the Internet are sales 9 connecttech com support connecttech com www connecttech com Note Please go to the Download Zone or the Knowledge Database in the Support Center on the Connect Tech website for product manuals installation guides device driver software and technical tips Submit your technical support questions to our customer support engineers via the Support Center on the Connect Tech website Telephone Facsimile Technical Support representatives are ready to answer your call Monday through Friday from 8 3
4. RXDe input O 38 5 pmr omp RXD input DSR input CTS input RXD am rx oup 6 TXD oupt TXD oupt 6 RI input CTS input 6 DCD ipu RXD input 6 DTR oupt RXD input Continued on next page 16 Revision 0 10 BlueStorm Installation Guide Connect Tech Inc 7 7 7 7 Table 3 VHDCI 68 Female Pinouts for BlueStorm LP Continued No Signal Direction Signal Direction 6 RTS oupt RTS foutput 6 DSR inu CTS input 6 RXD ipu TXDe oupt CTS input RIS ow output CTS output RI inpt CTS input DCD input RXD input O 7 RXD input TXDe output E RX RI input input input input input 8 RXD input TXDe output k js CTS input TRTS output Cable CBGO009 and or IOBGOS8BLV1 will send the signals to eight DB 9 male connectors See Table 6 for the DB 9 pinouts Cable CBGO026 will send the signals to eight DB 25 male connectors See Table 6 for the DB 25 pinout details Revision 0 10 17 BlueStorm Installation Guide Connect Tech Inc Table 4 HDB 78 Pinouts for BlueStorm SP 8 Port Connector Pin Port RS Signal RS 422 4
5. Tech Inc Figure 9 illustrates the jumper configurations for selecting 5V power or 12V power JA JB JAI JB1 e e JD1 A TxD control JA2 JB2 JD2 RxD control JA3 JB3 e e JD3 M RxD Termination Bias JA4 JB4 e e JD4 RxD Termination Bias JAS e JB5 JD5 TxD Termination Port 1 Port 2 Figure 7 Jumper Configuration Example for 4 Port RS 422 485 BlueStorm LP Models JA JB JC JAO JBO JCO e e RS 485 selection JA1 JB1 JC1 TxD control JA2 JB2 JC2 RxD control JA3 JB3 JC3 6 6 RxD Termination Bias JA4 JB4 Jc4 le e RxD Termination Bias JA5 JB5 e e JC5 je TxD Termination Port 1 Port 2 Port 3 Figure 8 Jumper Configuration Example for BlueStorm SP Opto Models J1 J1e ee J2 J2 position 12V power 09 J2 Ji position 5V power Figure 9 Jumper Configuration Examples for BlueStorm SP RJ 11 Models TxD Control Install this jumper to enable the RS 485 transmitter only when sending data This mode is useful for multi drop and half duplex operation when only one device is allowed to send data at a time If the jumper is not installed the transmitter will always drive the line to an idle state when not sending data RxD Control Install this jumper to enable the RS 485 receiver only when NOT transmitting data This is useful for two wire half duplex operation to prevent the transmitting device from receiving its own data as it sends If this jumper is not installed the re
6. input 14 NC jnoconct NC nocomnect as NC jnoconct NC noconmnect 16 NC jJnoconct NC jnoconmet 7 NC jnoconct NC jnmoconmet is NC necomet ne hoconnet Revision 0 10 13 14 BlueStorm Installation Guide Connect Tech Inc 21 NC jnoconet _ NC_ nocomect input Di NC mcommet NC_ no connect Cable CBGO002 sends the signals to two DB 9 male connectors See Table 6 for pinout details NOTE This is not the pinout of DB 25 cable CBG007 Table 2 HDB 44 Pinouts for BlueStorm LP 4 Port Connector Pin Port RS 232 Signal No No Signal Direction RS 422 485 Signal Signal Direction 6 2 RTS output RTS output 8 2 RxD Jiu TXDe output O 9 3 TXD output TXD output s 4 DCD Jinut RXDe input 16 fers input TSH output O 7 1 SG signal gnd SR signa ref 18 NC Jnoconect NC jnocomet 9 NC jnoconect NC nocomnect 20 2 fers input RTSc output O 21 2 SG signal gnd SR signa ref 22 NC jJnoconect NC jnocomet 23 3 CTS input RTS output O 24 3 SG signal gnd SR signa ref ps NC no connect
7. 0 a m to 5 00 p m Eastern Standard Time Our numbers for calls are Telephone 800 426 8979 North America only Telephone 519 836 1291 Live assistance available 8 30 a m to 5 00 p m EST Monday to Friday Facsimile 519 836 4878 on line 24 hours Revision 0 10 5 BlueStorm Installation Guide Connect Tech Inc Introduction Connect Tech Inc presents BlueStorm LP SP SP Opto and SP RJ 11 These high speed multi port communication adapters are designed for Low Profile LP and Standard Profile SP PCI compatible computers BlueStorm cards provide you with up to eight high performance serial ports and baud rates up to 1 8432 Mbps that are compatible with any standard serial communications application BlueStorm cards are fully PCI compliant Simply install your card into an available PCI slot in your computer and with Plug and Play installation and the hardware setup is complete BlueStorm cards are an ideal solution for multi port serial communications in applications such as Point of Sale Industrial Process Control Office Automation and Data Telecommunications They allow easy attachment of peripherals such as barcode scanners receipt printers card readers testing and monitoring equipment modems printers and any other device requiring serial communications Features Two four or eight high performance asynchronous serial ports in various RS 232 and or RS 422 485 electrical interface configurations Baud rates up to 921
8. 8 Signal No No 232 Direction 5 Direction Signal Signal 3 Z RI input CTS B signal gnd _ SR output RTS AC input CTS AC e input RTS B output RTS AC input CTS AC e RI input CTS BC inpt RI inpt CTSB inpt o a input RTS B SG signalgnd SR output RTS AC CTS input RTS B DSR input CTS AC RI inpt CTS BC inpt Nc Z Q no connect C no connect C Z Q output TxD AC RI i N NC no connect NC no connect X input TxD B output RxD AC X X J 4 Z Q eim output RxD AC D SG signal gnd NC no connect output TxD AC input RxD B SG signal gnd SR signal ref alala B 15 6 6 LH EN 8 l6 9 jJ6 5 js 6 s 7 js 18 s Bf 20 25 6 26 6 6 28 6 29 6 EM INN 35 8 36 s 37 8 38 s W O oo Continued on next page 18 Revision 0 10 BlueStorm Installation Guide Connect Tech Inc Table 4 HDB 78 Pinouts for BlueStorm SP Continued in Port RS Signal RS 422 48 Signal No 232 Direction 5 Direction Signal Signal RI N N Tx Rx DT D SG signalgnd SR____ signal ref _ Tx DT D Tx Rx DT D SG i Tx DT D signal gnd SR signalref DCD inpt RxD BC input Cable CAGOSFXDX and or the IOBGOSDBO9V1 will send the signals to eight DB 9 male
9. B 25 male ent REA Table 7 Pinouts and Control Signals for DB 9 Male Connectors BlueStorm SP Opto Only RS 232 RS 422 485 N C xD xD C G IC S S C Male DB 9 Connector T T aN ile e e e e5 O ee amp amp a9 Please note that the DB 9 pinouts for BlueStorm LP and BlueStorm SP differ from the BlueStorm SP Opto Revision 0 10 BlueStorm Installation Guide Connect Tech Inc Table 8 RJ 11 Pinouts for BlueStorm SP RJ 11 Ports 7 and 8 Only RS 232 Direction P7 P8 no connect Please note that ports 7 and 8 are not accessible through the factory installed bracket 22 Table 9 Pinouts and Control Signals for RJ 11 Connectors BlueStorm SP RJ 11 Only Ports 7 and 8 when a DB 9 cable part number CAG104K is attached DB 9 RS 232 mm No Signal Dineckon output output si gnal ground output Part CAG104K Technical Tip Please ensure that you terminate the CTS signal if your application does not use them The common way to do this is to connect CTS to RTS Failure to do so may result in loss of a performance on your BlueStorm SP RJ 11 adapter Ports 1 through 6 which are accessible through the factory installed bracket RS 232 Sigmi pirection TxD output psr fom Signal power ground 12 VDC output or 5 VDC J selects 5 VDC J2 selects 12 VDC RJ 11 Connector Revision 0 10 BlueStor
10. Connect Tech Inc Industrial Strength Communications BlueStorm Universal PCI User Manual Contact Information Connect Tech Inc 42 Arrow Road Guelph Ontario Canada NIK 1S6 Tel 519 836 1291 International 800 426 8979 Canada amp USA Fax 519 836 4878 Email sales connecttech com support 2 connecttech com URL www connecttech com CTIM 00015 Revision 0 10 June 4 2008 BlueStorm Installation Guide Connect Tech Inc Limited Lifetime Warranty Connect Tech Inc provides a lifetime warranty for all Connect Tech Inc products Should this product in Connect Tech Inc s opinion fail to be in good working order during the warranty period Connect Tech Inc will at its option repair or replace this product at no charge provided that the product has not been subjected to abuse misuse accident disaster or non Connect Tech Inc authorized modification or repair You may obtain warranty service by delivering this product to an authorized Connect Tech Inc business partner or to Connect Tech Inc along with proof of purchase Product returned to Connect Tech Inc must be pre authorized by Connect Tech Inc with an RMA Return Material Authorization number marked on the outside of the package and sent prepaid insured and packaged for safe shipment Connect Tech Inc will return this product by prepaid ground shipment service The Connect Tech Inc lifetime warranty is defined as the serviceable life of the p
11. Port 3 COMS EET F Gn CTI PCI UART Serial Port 4 COM6 we CTI PCI UART Serial Port 5 COM wo CTI PCI UART Serial Port 6 COM8 Baud Rate Mapping X CTI PCI UART Serial Port 7 COM9 300 Mapped To 230400 110 Mapped To 110 J CTI PCI UART Serial Port 8 COM10 a Printer Port LPT1 COM Port Number coms Clock Frequency possizoo H Processors E amp 9 Sound video and game controllers System devices mccum Cancel Help Universal Serial Bus controllers Line Bias Termination The RS 422 485 transceivers both transmit and receive are optionally biased to produce a line level mark condition through jumper selectable resistors These options are typically used in multi drop 4 wire connections Termination may also be required depending on your wiring configuration Each case must be evaluated to determine which options to enable Jumper Block Diagrams for BlueStorm BlueStorm LP 2 port models Note JB JC Jumper blocks are not cles e installed for ports RS 422 485 communicating in Jumper blocks RS 232 Male DB 25 JA JB JA f f JB Port 2 Auto 485 Jumper block je o o o JC e o 0 0o ooo I JB5JB4JB3JB2JBI J Port 1 Auto 485 Notinuse e gt o oe o 0 0o ooo JAS JA4 JA3JA2 JA1 Revision 0 10 BlueStorm Installation Guide Connect Tech Inc Figure 1 BlueStorm LP Jumper Block Locations 2 Port Models BlueStorm LP 4 port models Note JB Je JD Jumper blocks
12. agnetic Compatibility EMC Directive for General Immunity Compliance EN 50 0082 1 1997 EN 55022 Conducted and Radiated emissions CISPR 22 Class A EN 55024 Immunity to Disturbances EN 61000 4 2 EN 61000 4 4 EN 61000 4 3 EN 61000 4 6 The above satisfy the requirements of USA FCC Class A 47CFR Part 2 FC Canada ICES 003 IM mum Europe EMC Directive CE Japan VCCI Australia New Zealand AS NZS The above agency conformances were met by independent laboratory testing of Connect Tech Inc product s with shielded cables with metal hoods attached to either the terminating connectors or cable assemblies supplied with the product s Failure to follow good EMC EMI compliant cabling practices may produce more emissions or less immunity than were obtained in laboratory measurements Operation of this equipment in a residential area may cause unacceptable interference to radio and TV reception requiring the user to take whatever steps necessary to correct the interference Revision 0 10 27
13. are not HHHHH esses Bieeel installed for ports RS 422 485 communicating in Jumper block RS 232 Female HDB 44 JA JB JC JD Ja EE N JD Port 4 a z eoo oe JxtJ Ux3 Jx4 Jx5 JX6 ecco JB Port 2 JA Port 1 JD5JD4JD3JD2JD1 em ee e oo oo JC Port 3 eec Q 0 0o0o9 9 9 9 9 JB5 JB4 JB3JE2 JB1 JA5 JAA JAG JA JA1 eoo 090 JC5JC4JC3 JC2JC1 Figure 2 BlueStorm LP Jumper Block Locations 4 Port Models BlueStorm LP 8 port models Note se ies aa Ty Jumper blocks are not installed JE 22 ee JF ze se for ports communicating in EL selee RS 232 Female Jc ES ES VHDCI68 os ss JA Port 1 Jx ee e JB Port 2 e e Jx 1 JA JB JC Port 3 eoe Jx2 nes JD Port 4 e e x3 ES x MED Po e Jx5 JG Port 7 s I JH Port 8 Figure 3 BlueStorm LP Jumper Block Locations 8 Port Models Revision 0 10 BlueStorm Installation Guide Connect Tech Inc Note Jumper blocks are not installed e EI u BHH BHH for ports only capable of communicating in Finis SESH pnm o opm Reo HDB 78 d eg ea eae fea Jx1 Jx2 Jx3 Jx4 Jx5 Jx6 JA z Port 1 JB Port 2 a EHH JC Port 3 JD Port 4 lt JE Port 5 JEHA JF Port 6 JG Port 7 JH Port 8 Figure 4 BlueStorm SP Jumper Block Locations 8 Port Models Note Jumper blocks are not installed for ports communicating in RS 232 P4 JX ELL 1 e HHHEH e e e e e e
14. ation eoi tet a te cnet ete redolet Ste dte Dasa sees elit Sata dr edu Auto485 orcas Ae e He ee pieles eee r eee Power On Tri state BlueStorm SP Models Only Excludes BlueStorm SP RJ 11 13 Connectors and Pinouts Hardware Installation eese Software Driver Installation eese Specifications nis the EE es ER t eee idit t EE ALL Operating Environment PCEBus Interface iopen entree ed det ene COmMUMICALIONS a PEE Baud Res eec ettet tbi nt bee e ttbi b e e estet Nullo mp Optical solatio 75 niim bammeeia nae ane TU DIMENSIONS MEME PI Certifica P List of Figures Figure 1 BlueStorm LP Jumper Block Locations 2 Port Models see Figure 2 BlueStorm LP Jumper Block Locations 4 Port Models seen Figure 3 BlueStorm LP Jumper Block Locations 8 Port Models see Figure 4 BlueStorm SP Jumper Block Locations 8 Port Models see Figure 5 BlueStorm SP Opto Jumper Block Locations 4 Port Models sess Figure 6 BlueStorm SP RJ 11 8 Port Model sess ener nennen enne entente Figure 7 Jumper Configuration Example for 4 Port RS 422 485 BlueStorm LP Models Figure 8 Jumper Configuration Example for BlueStorm SP Opto Models sess Figure 9 J
15. ceiver is always enabled and ready to receive data RxD Termination Bias Install this pair of jumpers to enable a 120 or 150 ohm terminator model dependent across the RxD and RxD pins for the corresponding port A biasing network is also enabled that drives the receiver to an inactive or safe mode The receiver can still receive data from another device and the biasing helps to prevent the reception of data generated by noise on the transmission line The two jumpers for RxD termination bias must be installed and removed as a pair TxD Termination Install this jumper to enable a 120 or 150 ohm resistor model dependent across the TxD and TxD pins of the corresponding port Auto 485 BiueStorm LP 2 port RS 422 485 models and BlueStorm SP Opto models only Install this jumper to tri state the transmitters of ports configured as RS 485 half duplex or multi drop slave when the computer powers up or is reset This jumper will be overridden once Revision 0 10 BlueStorm Installation Guide Connect Tech Inc the operating system is booted by the current driver software RS 485 mode The jumper is used to ensure that a port will power on tri stated For example the RS 485 mode selection in the Windows control panel will override this jumper setting once a port is opened The BlueStorm LP RS 422 485 uses JC to configure Auto 485 mode while the BlueStorm SP Opto uses J1 Note that on BlueStorm LP RS 422 485 models the Auto 485 is a s
16. connections OR in multi drop 2 wire bus connections This mode requires software setup in Control Panel System Hardware Device Manager Ports CTI PCI UART Click on Advanced under Port Settings after the driver is installed See multi drop slave below Revision 0 10 7 BlueStorm Installation Guide Connect Tech Inc Multi drop Slave Mode e Manager In this mode the TxD line driver is enabled only when data is transmitted and RxD is enabled at all times This mode is typically used in multi drop 4 wire connections This mode requires software setup in Control Panel System Properties Hardware Device Manager Ports CTI PCI UART Click on Advanced under Port Settings FRED CTI PCI UART Serial Port 1 2 x e m amp ei9mu ma General Port Settings Driver Details Resources Advanced Settings E X E S Multi port serial adapters v F f gt 33 CTI 8 PORT PCI UART R5232 485 423 Use FIFO Buffers FZ R 495 Options H E Network adapters Sle a 5 t gs to correct connection problems Defaults Full Duplex GY Ports COM amp LPT Select higher settings for faster performance A Communications Port COM1 Receive Buff Lowit X Communications Port COM2 EXONOEXICT dra 0 pee x High 64 56 C 1 2 Duplex e UART Serial Port 1 COM3 ue fer V CTI PCI UART Serial Port 2 COM4 Transmit Buffer Low 1 p O D wn High 64 56 C Multi Drop Slave a CTI PCI UART Serial
17. connectors See Table 6 for the DB 9 pinouts Cable CAGO8DB25 will send the signals to eight DB 25 connectors See Table 6 for the DB 25 pinouts N N SR SR RI INC INC TxD RxD DTR DCD SG i TxD RxD DTR output RxDA input DCD TxD RxD input TxDB output DTR DCD SG i TxD RxD DTR C C D D a CD i D B CD RxD BO D TD AO D 1 CD i D B CD i C EN Revision 0 10 BlueStorm Installation Guide Connect Tech Inc Table 5 RJ 45 Pinouts for BlueStorm SP Opto 4 Port Connector ose E Tae 89 ome Pin No Signal Direction Signal Direction 2 NC in RDG input SG signagnd SR signalref 5 TxD output TxD output 6 RxD input RxD input il RJ 45 connector Cable CAGRJ4509 will send the signals to eight DB 9 male connectors See Table 7 for the DB 9 pinouts 20 Revision 0 10 BlueStorm Installation Guide Connect Tech Inc Table 6 Pinouts and Control Signals for DB 9 and DB 25 Male Connectors BlueStorm LP and BlueStorm SP Only Ping RS232 RS 422 485 O DB 9 DB 25 Signal Signal Direction Signal Signal Direction 8 DOD input RD ipt i O e fe Ds me lers fine output S s fers mw RTS opt o fa R mw cts m DB 9 male D
18. e the BlueStorm card to the computer chassis Software Driver Installation BlueStorm provides support for QNX 4 X 6 X Windows 2000 CE NT XP XPe XP 64 Bit Server 2003 Server 2003 64 Bit Vista VxWorks Ardence RTX and Linux For installation guidelines and driver codes please refer to the appropriate directories on the BlueStorm CD For further information concerning software installation of BlueStorm products please visit Connect Tech s Download Zone If you are interested in a device driver for an operating system not listed please contact the Connect Tech Sales Department Specifications Operating Environment BlueStorm LP m Storage temperature 55 C to 125 C m Operating temperature 0 C to 70 C m Humidity 5 to 95 non condensing BlueStorm SP BlueStorm SP Opto and BlueStorm SP RJ 11 m Storage temperature 55 C to 105 C m Operating temperature 0 C to 70 C m Humidity 5 to 9596 non condensing PCI Bus Interface BlueStorm LP 3 3V or 5V PCI bus Please note that the BlueStorm LP can ship with low and standard profile brackets BlueStorm SP BlueStorm SP Opto and BlueStorm SP RJ 11 3 3V or 5V PCI bus Communications Baud Rates RS 232 50 bps 921 6 Kbps RS 422 485 50 bps 1 8432 Mbps Custom baud rates are also available please contact our Sales Department for information Revision 0 10 25 BlueStorm Installation Guide Connect Tech Inc UARTs BlueStorm LP 2 port models a 17D152 d
19. ingle jumper The second site is not in use See Figure 1 for the location of this jumper On the BlueStom SP Opto the first position controls the first port pair while the second position controls the second port pair Power On Tri state BlueStorm SP Models Only Excludes BlueStorm SP RJ 11 BlueStorm SP models offer a power on tri state similar to the Auto 485 mode listed above The BlueStorm SP will tri state a port configured as RS 485 full duplex or RS 485 multi drop slave This is meant to ensure compatibility with our legacy Blue Heat PCI cards for customers upgrading to the newer BlueStorm family Jumper J1 controls the power on tri state functionality Install a jumper on the first location of the J1 in order to tri state Port 1 at power on install a jumper on the second position of J1 to control Port 2 etc Ports will not come out of tri state until the driver opens the associated port and begins transmission Half Duplex and Multi drop Slave modes require you to select the appropriate mode via software Please refer to the readme txt files found in the appropriate directories on the BlueStorm LP SP SP Opto CD Connectors and Pinouts Table 1 DB 25 Male Pinouts for BlueStorm LP 2 Port Connector No No Signal Direction Signal Direction output 6 1 DSR input CTS imput 8 DCD input RXDe input O 9 2 TXD jJoupt TXD output O
20. m Installation Guide Connect Tech Inc Revision 0 10 External I O Box part number IOBGO8BLV1 Male DB 9 connectors t Q Mounting bracket Figure 10 BlueStorm External I O Box Diagram Note View VHDCI 68 connector pinouts in Table 3 I O box IOBGO8BLV1 will send the signals to eight DB 9 male connectors See Table 6 for the DB 9 pinouts 23 BlueStorm Installation Guide Connect Tech Inc RS 422 485 2 Wire Diagram RS 422 485 4 Wire Diagram BlueStorm LP SP RS 422 485 BlueStorm LP SP RS 422 485 Adapter Peripheral Adapter Peripheral 9 9 Figure 11 RS 422 485 Wiring Diagrams BlueStorm LP and BlueStorm SP Only RS 422 485 RS 422 485 2 Wire Diagram 4 Wire Diagram BlueStorm SP Opto RS 485 422 BlueStorm SP Opto RS 422 485 Adapter Peripheral Adapter Peripheral e Figure 12 RS 422 485 Wiring Diagrams BlueStorm SP Opto Only 24 Revision 0 10 BlueStorm Installation Guide Connect Tech Inc Hardware Installation Turn the power off to your computer and open it to expose the expansion slots consult your system s documentation for more information about this procedure Choose an available PCI expansion slot remove the expansion slot cover and insert the BlueStorm adapter pushing down gently until the board seats fully in the slot Secur
21. no connect oome NC p 26 NC jnoconet NC nocomnect 27 4 CTS input RTSc output O 28 4 SG signal gnd SR signlref 29 NC noconect NC nocomnect_ output input 32 1 DTR Joupt RXD input 33 RI Jiu TSH input Ne 34 NC noconnect no connect 35 2 DSR Jinut CTS input Revision 0 10 BlueStorm Installation Guide Connect Tech Inc 38 Nc fnocomect NC 42 4 DSR input CTS Ho 4 DIR output RXD 000 44 4 input CTS input input Cable CBG003 sends the signals to four DB 9 male connectors Cable CBG007 sends the signals to four DB 25 connectors See Table 6 for pinout details Revision 0 10 15 BlueStorm Installation Guide Connect Tech Inc Table 3 VADCI 68 Female Pinouts for BlueStorm LP 8 Port Connector No No Signal Direction Signal Direction input 6 DSR fimput CTS input 8 CTS ipt RTSe oupt O 9 2 TXD ouput TXD j oupt input input 15 2 RXD input TXDe OO oupt O 16 2 CTS inu RTSe OO oupt L7 L2 psa signal gnd _ SR__ signal ref input input 37 5 DCD ipu
22. nts does not constitute a lack of acknowledgment to the rightful owners of the trademarks and copyrights mentioned in this document 2 Revision 0 10 BlueStorm Installation Guide Connect Tech Inc Table of Contents Lammited Lifetime Warranty 21 bee re eR Miseni bee teneret Copyright Not E eor em ann une e dede Trademark Acknowledgment esee Table of Contents soeren ieor AERAR TETKA E REKA E AERE E EANET TASUOPPIQUICS Sonis roaa a a E E a Saks eod Ui a Bs a E OEE List of Tables Customer Support Overview essere Contact Information e erem Heer eec a D er e P E ER OP EEL eai Hoodie Fedt te Siren nre ee n eE a E E aE ESAT BlueStorm Installation Overview esee Hardware Configuration Interrupts and Memory Address Selection RS 422 485 Electrical Interface Configuration ssssseessssssseeeeeneneennn 7 Full Duplex Mode 3 2 eue e HR RR ON HDI EE des 7 Half Duplex Mode eene etae oe ehe eae ee dead anoi ee Tb ta eee Poeta 7 Multi drop Slave Mode ie e one REG Rire ee en Rh 8 Line Bias Termination Jumper Block Diagrams for BlueStorm esses ene enn eetne trennen Jumper Configuration for BlueStorm eese nennen eterne eneenetne trennen TxD CGonttol ete ED RD Coito 829 3 esu end ene eae RxD Terniination Bias n IR pecie e eee pete eed TID X Termin
23. roduct This is defined as the period during which all components are available Should the product prove to be irreparable Connect Tech Inc reserves the right to substitute an equivalent product if available or to retract lifetime warranty if no replacement is available The above warranty is the only warranty authorized by Connect Tech Inc Under no circumstances will Connect Tech Inc be liable in any way for any damages including any lost profits lost savings or other incidental or consequential damages arising out of the use of or inability to use such product Xtreme 104 Wireless Radio Modems include a one year warranty only Copyright Notice The information contained in this document is subject to change without notice Connect Tech Inc shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing performance or use of this material This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of Connect Tech Inc Copyright O 1997 2008 by Connect Tech Inc Trademark Acknowledgment Connect Tech Inc acknowledges all trademarks registered trademarks and or copyrights referred to in this document as the property of their respective owners Not listing all possible trademarks or copyright acknowledgme
24. s section outlines jumper settings and configuration 2 Hardware Installation Installation involves the physical installation of the BlueStorm into your computer Please note that you should configure any jumper settings prior to installing the board 3 Software Driver Installation Load the appropriate driver for your Operating System as found on the accompanying CD Installation guides are also available on the CD to aid you in this process Hardware Configuration Interrupts and Memory Address Selection All BlueStorm products are PCI cards Therefore the host computer s BIOS will automatically set interrupts and memory addresses when you reboot after installation RS 422 485 Electrical Interface Configuration Some BlueStorm adapters support RS 422 485 communication as outlined below See Figure 1 through to Figure 6 for configuration jumper block locations It may be necessary to configure the card to match your particular wiring configuration Please see the Jumper Configuration for BlueStorm section below for configuration examples Full Duplex Mode In this mode TxD and RxD are being driven to a known level at all times This mode is typically used in point to point situations much like RS 232 Half Duplex Mode In this mode the TxD line driver is enabled only when data is transmitted and RxD is disabled when data is being transmitted This mode is typically used in either point to point 2 wire
25. ual UART with 64 byte TxD RxD FIFO buffers BlueStorm LP 4 port models a 17D154 quad UART with 64 byte TxD RxD FIFO buffers BlueStorm LP 8 port models a 17D158 octal UART with 64 byte TxD RxD FIFO buffers BlueStorm SP and BlueStorm SP RJ 11 8 port models a 17D158 octal UART with 64 byte TxD RxD FIFO buffers BlueStorm SP Opto 2 and 4 port models a 17D152 dual UART s with 64 byte TxD RxD FIFO buffers Surge Suppression BlueStorm LP SP SP RJ 11 excludes BlueStorm SP Opto TransGuard Transient Voltage Suppression able to withstand multiple strikes on every signal of every port m Transient Energy dissipation 0 05 joules on every signal of every port m Transient peak current rating 15A on every signal of every port a EN61000 4 2 3 4 compatible Optical Isolation BlueStorm SP Opto m 3kV peak to peak optical isolation on every signal of every port Dimensions BlueStorm LP Low profile form factor MD1 compliant BlueStorm SP Length 11 991 cm 4 721 inches Height 9 652 cm 3 8 inches BlueStorm SP Opto Length 14 702 cm 5 788 inches Height 10 605 cm 4 175 inches BlueStorm SP RJ 11 Length 12 129 cm 4 775 inches Height 10 668 cm 4 2 inches 26 Revision 0 10 BlueStorm Installation Guide Connect Tech Inc Certification Connect Tech Inc declares that the product s covered by the contents of this manual have been tested and found compliant with the below listed standards as required by the Electrom
26. umper Configuration Examples for BlueStorm SP RJ 11 Models esses Figure 10 BlueStorm External I O Box Diagram sees tenete Figure 11 RS 422 485 Wiring Diagrams BlueStorm LP and BlueStorm SP Only Figure 12 RS 422 485 Wiring Diagrams BlueStorm SP Opto Only eee Revision 0 10 BlueStorm Installation Guide Connect Tech Inc List of Tables Table 1 DB 25 Male Pinouts for BlueStorm LP 2 Port Connector sse 13 Table 2 HDB 44 Pinouts for BlueStorm LP 4 Port Comnector ccccceecccceesseceeeeeceeessnececseseeeeeneeaeeeeaes 14 Table 3 VHDCI 68 Female Pinouts for BlueStorm LP 8 Port Connector sese 16 Table 4 HDB 78 Pinouts for BlueStorm SP 8 Port Connector enne 18 Table 5 RJ 45 Pinouts for BlueStorm SP Opto 4 Port Connector seen 20 Table 6 Pinouts and Control Signals for DB 9 and DB 25 Male Connectors BlueStorm LP and BlueStorm SP Only 25 m eU Doe Up RR e ie E WE ens 2l Table 7 Pinouts and Control Signals for DB 9 Male Connectors BlueStorm SP Opto Only 21 Table 8 RJ 11 Pinouts for BlueStorm SP RJ 11 Ports 7 and 8 Only sse 22 Table 9 Pinouts and Control Signals for RJ 11 Connectors BlueStorm SP RJ 11 Only 22 4 Revision 0 10 BlueStorm Installation Guide Connect Tech Inc Customer Support