1. The Reclose Timer pot R94 is adjustable from 0 to 250 seconds Turning the pot clockwise increases the reclose time NOTE Pot in figure is set to O seconds 1 To enable the Timer set switch S1 2 TIMER to the ON right position Turn the pot fully counterclockwise Open the gate Gate should close almost immediately when it reaches the open limit Adjust the pot slightly clockwise Open the gate Note the delay between the gate reaching the open limit and starting to close Repeat steps 4 and 5 until the desired relcose time is set Doc 6001242 01 20273 17 of 53 18 of 53 POWER FAIL OPERATION OPTION CONNECTION a Power Fail Operation Option Connection CAUTION Perform the next step battery hookup with care Interchanging battery wires temporarily opens the the resettabale fuse on gate operator board disabling the power fail option To ensure a safe installation the gate operator is shipped with the battery partially disconnected from the Power Fail Option electronics To enable this option b Connect white red wire of option harness to positive battery terminal Power Fail Operation Option Test NOTES The following procedures require turning main power to the gate operator off and on at its dedicated circuit breaker DO NOT shut off the Gate Operator Power switch unless specifically directed by the procedure since this will shut off everything including the Power Fail Operation opti
2. 1 Turn on circuit breaker that provides power to gate operator 2 On Manual Input Terminal TB2 connect the STOP terminal to the COMMON terminal see Figure 5 3 Turn on gate operator power switch and verify that the row of LEDs on the right side of the controller board all turn on then turn off sequentially starting from the bottom The only LEDs that should remain on are Power ON MAGLOCK and CLOSE LIMIT or OPEN LIMIT if one of the limit switches are engaged NOTE If the LEDs do not follow this pattern the controller board may not be working correctly Stop installation and call LiftMaster Technical Support for assistance 4 On Manual Input Terminal TB2 disconnect the STOP terminal from the COMMON terminal Doc 6001242 01 20273 9 of 53 F USING MANUAL CONTROLS MANUAL CONTROL MANUAL INPUT TB2 CONTROL H BOARD 1204F15A Figure 5 Manual Controls Location and Use Use the manual controls on Manual Input Terminal TB2 OPEN CLOSE and STOP as shown in Figure 5 to move the gate for arm installation and making the limit cam adjustments e open the gate connect the OPEN and STOP terminals to the COMMON terminal e Toclose the gate connect the CLOSE and STOP terminals to the COMMON terminal To stop the gate disconnect the STOP terminal from the COMMON terminal IMPORTANT NOTE If the STOP terminal is disconnected from the COMMON terminal the gate is prevented from moving and no command will affec
3. Support drive shaft 8 TrayAssemby Convenience tray holds optional equipment 9 TorqueLimiter si Transmits drive power to chain not shown Maintains tension on chain not shown Drive Chain Cover not shown 50 of 53 Doc 6001242 01 20273 Rev C Rev C GLOSSARY AC Alternating Current An electric current or voltage that reverses direction at regular intervals Alternate Action Ability to open and close a fully open gate by using the same open command Arc The area that is swept by a swing gate from fully closed to fully open position ATG Anti tailgating refers to a method of immediately closing an opening gate behind a vehicle so that an unauthorized vehicle can not follow the authorized vehicle through the gate DC Direct Current An electric current of constant value flowing in one direction only Dynamic braking Stopping the gate by activating the forward and reverse windings of the gate operator motor in each half AC cycle Fault An abnormal condition which causes the gate to stop to protect the gate and the user Gate sensitivity The response of the gate operator to an exerting force to the gate Gear Box A device that changes the speed and power of its driving force motor Inrush current Initial current drawn into an electrical device due to its capacitive or inductive nature Interrupt Bar or Edge A switch which is installed at the edge of a gate to protect an object which is situated between the
4. NOTE Battery capacity decreases over time Battery should be replaced every two or three years e The charging section and controls for the Power Fail Operation are located on the control board e The motor sensing potentiometers Right reverse Left reverse and Inrush on the Gate Operator board may require readjustment if the Power Fail Operation option is installed in the field e Gate speed may be slightly reduced with the Power Fail Operation option installed IMPORTANT NOTE During a power outage all Gate Operator safety features are disabled and only the limit switches stop movement of the gate C GATE OPERATOR COVER WITH ACCESS DOOR This optional cover allows access to the gate operator control board without first having to remove the gate arm and operator cover Just unlock the door a standard LiftMaster lock gently tip the top of the door then lift and remove the door Rev C Doc 6001242 01 20273 33 of 53 PART 5 TROUBLESHOOTING AND MAINTENANCE A TROUBLESHOOTING This section is designed to help you troubleshoot your unit s with a minimum of effort Directly below are some hints to help you test then a list of problems in order of most severe to least Next comes a quick reference list of faults and how to clear them and then a list of faults and their causes Testing Control Board inputs To test an input connect the input terminal to the COMMON terminal on the Control Board and verify that its LED turns on m
5. Reclose Timer settings Inputs affect one gate operator only so connect inputs separately to each gate operator 30 of 53 Doc 6001242 01 20273 Rev C Rev C 4 TANDEM GATE DETAILS The Tandem gate is typically used in high traffic situations where some control of incoming and or outgoing traffic is required The outside gate is usually a less expensive fast moving barrier gate or light slide gate which protects the more expensive and less mobile Slide or Swing inside gate The outside gate does this by stopping the vehicle until the inside gate is completely open The Tandem configuration can consist of any LiftMaster model for Master and a model SL 1000 B1 slide gate or BG 3000 B1 barrier gate for Slave NOTE The SW 2000 B1 swing gate may not be used for Slave SWITCH 51 SETTINGS JTS Slide Unit 4 COMPLEX Option Timer Unit Option Reiny Unit ption ATG OFF Master ON Trap ON Operator Shadow Loop Master swing gate only Master SWITCH S1 SETTINGS Slide Unit Option Timer Unit Option Ran Unit MagLock ption Manual ATG Unit Inputs Option Master OFF Trap OFF Operator Slave m Outside Interrupt 4 Affects both units Loop STREET Figure 19 Typical Tandem Gate Installation HOW IT WORKS When a vehicle is entering or exiting the inside Master gate opens first When the Master is completely open the outside Slave gate opens allowing the vehicle to enter or exit The M
6. a stuck input Entry system is connected to the Manual Input by mistake Rev C Doc 6001242 01 20273 35 of 53 10 GATE DOESN T STOP AT THE LIMIT 1 Limit cams are out off adjustments 2 Limit switch cable is disconnected either from the control board or the limit switches 3 Bad limit switch 11 MOTOR STOPS BUT GATE OVERRUNS THE LIMIT Torque limiter slips when the motor stops The torque limiter is factory adjusted for 75 ft Ib 12 GATE IS TOO SLOW 1 Low input AC voltage 2 Hardened or frozen gate hinges 3 Slipping torque limiter or belt 13 GATE DOESN T STAY OPEN CLOSED WITH MANUAL FIRE INPUTS 1 Manual inputs or Fire were only activated momentarily not continuously 14 GATE DOES NOT CLOSE AUTOMATICALLY 1 Reclose timer setting is OFF 2 The entry system is connected to Manual open by mistake 3 An input is continuously activated stuck 15 OPERATOR DOESN T RESPOND TO COMMANDS FOR A MINUTE 1 Afault has occurred and Retry is set to OFF 16 ALTERNATE ACTION DOES NOT WORK 1 ATG and Reclose Timer are ON 2 Entry system is connected to the Manual Input by mistake 17 GATE DOES NOT OPEN TO THE CORRECT DIRECTION 1 The power was not cycled after changing the setting of switch S2 2 Limit switches are miswired 18 AN OPEN GATE DOES NOT CLOSE AT POWER UP 1 An input is continuously activated Stuck 2 The gate was not on the open limit switch when the power went out
7. be connected to the Inside loop detector In Bi Parting and Bi Parting Latch Master Slave systems to enhance system safety Interrupt loops Shadow loops and Interrupt Bar switches may be connected to both gates If this is done when connecting the two control boards do not interchange input and common terminals If terminals are interchanged inputs will not be detected and controller boards may be damaged POST INSTALLATION PROCEDURES 1 Setup Turn on the main power at the gate operator s circuit breaker Verify that switch S2 the Gate Open Direction switch is set to the correct position Turn on the unit power switch on master slave systems turn on slave and then master 2 Manual inputs Verify that Manual Open fully opens the gate and that the open limit switch stops the gate Verify that Manual Close fully closes the gate and that the close limit switch stops the gate Verify that Manual Stop stops the gate Note If the gate stops due to a Reverse Fault readjust the gate sensitivity pot Use the Manual Input commands to verify that The gate swings open and closed smoothly There is no squeak or vibration in the gate when it is moving There is no belt and torque limiter slippage when the gate moves or stops There is no slack in the closed gate due to loose chain or parts Both gates open and close at the same time Bi Parting gates only 4 Gate sensitivity Left Right Reverse sensitivity App
8. broken The belt or torque limiter slips during gate movement Limit switch cable is disconnected Bad limit switch Stalled motor 4 IF OPEN MTR LED IS TURNED ON ONLY The motor thermal overload switch is popped The wires connecting the motor to the Control Board are disconnected Bad motor 5 IF FAULT LED IS TURNED ON ONLY A limit switch is stuck closed The belt was broken before the start of the gate movement Interrupt Bar switch is activated Stalled motor at open or close limit Rev C Doc 6001242 01 20273 39 of 53 MAINTENANCE WARNING To avoid injury always turn off the unit power switch before working on gate Regularly performance of preventive maintenance is essential for reliable system operation because it corrects small problems before they turn into emergencies LiftMaster recommends performing preventive maintenance every 6 to 12 months depending upon the amount of gate usage If the gate is installed in a private residence or small apartment house where usage is not severe yearly preventive maintenance is acceptable If the gate is installed in a high traffic application semi annual preventive maintenance is essential PREVENTIVE MAINTENANCE TASKS 40 of 53 Gate Arm Check for wear in the moving parts Check for hardware tightness Gate must swing freely without any impediment Check hinges grease if necessary Chain Check for wear and tension If loose adjust te
9. closing If gate is opening or fully open as soon as the Loop clears the gate immediately begins closing to discourage tailgaters Dynamic Braking When SLIDE is ON gate brakes whenever it stops When SLIDE is OFF gate brakes only at open or close limit Sets the Reclose Timer to OFF left or ON right When enabled the timer controls how long the gate waits at the open limit before closing The Reclose Timer can be set from 0 250 seconds by adjusting the Reclose Timer pot R94 During a power outage if the gate is fully open and TIMER is ON the Reclose Timer starts after the restoration of power causing the fully open gate to close automatically Sets the Retry function to OFF left or ON right When enabled if the gate meets an obstacle a closing gate reverses and an opening gate stops waits 30 seconds then tries to resume The gate will re try twice before it faults out Sets Anti Tailgate function to OFF left or ON right The Anti Tailgate feature helps prevent two cars from entering on one OPEN command In conjunction with the TRAP switch sets configuration for master slave system In conjunction with the MASTER switch sets configuration for master slave system Doc 6001242 01 20273 Rev C Rev C 2 RECLOSE TIMER ENABLE S1 AND SET R94 7 OFF S1 ON R94 250 RECLOSE Sec sec s TIMER 7 2 CONTROL BOARD Figure 11 Reclose Timer Enable and Adjustmment Location
10. gate does not open within 10 seconds the first gate reopens to let the vehicle exit the trap area e ATG Anti TailGating is always active for both Master and Slave gates Each gate closes as soon as its Inside Interrupt loop clears e Faults and Manual Input Commands in one unit affect both units Acontinuous FIRE or Manual OPEN input in either gate opens the gates and holds them open e vehicle stalls between the gates and they close they can be opened by a CYCLE or RADIO command or by driving over the Master unit Outside Interrupt Loop the Slave unit Inside Interrupt Loop SLIDE ON only or the optional Exit Loop Doc 6001242 01 20273 29 of 53 There are 2 different ways to close the gate entering or exiting 1 Reclose Timer When the Reclose Timer expires gate closes automatically Master or Slave 2 Interrupt Loop clearing the Inside Interrupt Loops cause the gates to close Master or Slave NOTE To ensure gate closure set Reclose Timer ON in both Master and Slave INPUT CONNECTIONS for more details refer to Part 2 Paragraph L Connecting Input Wiring e Master and Slave units require their own separate inputs e f Radio inputs are used in both units each requires its own transmitter and entry code MASTER UNIT SWITCH S1 SETTINGS AND INPUTS Gate SLIDE Reclose Operator Unit Unit Unit SLAVE UNIT SWITCH S1 SETTINGS AND INPUTS Unit Unit Unit Master and Slave units can have different
11. the gate from closing When the Loop clears the gate resumes closing If gate is opening or fully open as soon as the Loop clears the gate immediately begins closing to discourage tailgaters Dynamic Braking When SLIDE is ON gate brakes whenever it stops When SLIDE is OFF gate brakes only at open or close limit TIMER Sets the Reclose Timer to OFF left or ON right When enabled the timer S1 2 controls how long the gate waits at the open limit before closing The Timer can be set from 0 250 seconds by adjusting the Reclose Timer pot R94 During a power outage if the gate is fully open and TIMER is ON the Reclose Timer starts after the restoration of power causing the fully open gate to close automatically RETRY Sets the Retry function to OFF left or ON right When enabled if the gate meets S1 3 an obstacle a closing gate reverses and an opening gate stops waits 30 seconds then tries to resume The gate will re try twice before it faults out ATG Sets Anti Tailgate function to OFF left or ON right The Anti Tailgate feature S1 4 helps prevent two cars from entering on one OPEN command MASTER In conjunction with the TRAP switch sets configuration for master slave system S1 5 TRAP In conjunction with the MASTER switch sets configuration for master slave system S1 6 NOTE For swing gate operation controls are Right Clockwise and Left Counterclockwise SWITCH S2 GATE OPEN Selects the direction the g
12. 3 TIMER on switch S1 is set to OFF 36 of 53 Doc 6001242 01 20273 Rev C 19 GATE DOES NOT MOVE AFTER POWER OUTAGE Bad Power Fail Option battery Miswired DC motor inputs Bad connection between the Power Fail Option harness connector and the Control Board Power Fail Option Open direction switch S3 is not set to the correct position Battery is connected backwards causing resettable fuse on the control board to open 20 POWER FAIL OPTION WORKS BUT GATE DOESN T STOP AT LIMIT 1 Miswired DC motor inputs 2 Bad Power Fail Option harness 21 BATTERY DOESN T RECHARGE WITHIN 4 TO 5 HOURS AFTER USE 1 Old or bad battery 2 Bad harness 3 Bad Control board 22 POWER FAIL OPTION MOVES THE GATE TOO SLOWLY 1 Old or not fully charged battery 2 Hardened or frozen gate hinges 3 Slipping torque limiter or belt 4 Belt is too tight 23 THERE IS SLACK OR PLAY IN THE GATE Chain is too loose The hardware interconnecting the operator to the gate is not tight The large mounting bolt or the jam nut for the cap arm is not tight Set screws on the sprocket or the torque limiter are not tight 24 ATG ANTI TAILGATE DOES NOT WORK 1 The ATG setting on switch S1 is OFF 2 Entry system is connected to Manual Open by mistake 3 Interrupt loop or loop detector is not working properly 25 INTERRUPT LOOP DOES NOT ACT PROPERLY 1 Improper SLIDE and ATG settings 2 Badloop sensor or loo
13. 3 TB14 TERMINAL 1 Lift head off i terminal pins BLOCKS OUTSIDE NSIDE INTERRUPT LOOP INTERRUPT LOOP SHADOWLOOP EXIT LOOP ETECTOR DETECTOR DETECTO Q Loosen screws XMIT Insert wires Tighten screws SWITCH S1 Replace head m i on terminal orr S1 Figure 15 Master Slave Connection and Switch S1 Location Rev C Doc 6001242 01 20273 25 of 53 D MASTER SLAVE SETUP PROCEDURE Be sure to turn off both gate operator units Connect Master and Slave units as described and shown in paragraph C and Figure 15 above Set Switch S1 on Master and Slave units to your gate configuration according to the table below NOTES If before power up the Master Slave connection is broken one of the units is turned off or one of the controller boards malfunctions the gates will operate in stand alone configuration If the Master Slave connection is broken after power up it prevents either gate from moving MASTER UNIT SWITCH S1 SETTINGS AND INPUTS atte atte ov o oe Unit Unit Unit Oooo Select ATG Timer and or Retry if desired from the Master unit and set Slave ATG Timer and Retry to OFF Otherwise the ATG ON shorter Reclose Sena ON in either unit supersedes the other Master and Slave units can have different settings Inputs affect both gate operators so connect to one unit only Inputs affect one gate operator only so connect inputs separately to each gat
14. 5 Troubleshooting and Maintenance Indicates the motor is engaged but is not drawing any current The thermal overload switch on the motor may need to be reset See Fault List in Part 5 Troubleshooting and Maintenance NOTES The term activation means closing an input circuit via a relay or switch and may be momentary or continuous Momentary activations are superceded by any command Continuous activations are superceded only by an overriding command Activating any command when gate is at the open limit stops the Reclose Timer When the command except Manual CLOSE and STOP is cleared the Reclose Timer is reset MANUAL INPUTS OPEN CLOSE AND STOP TB2 MAN OPEN MAN CLOSE MAN STOP Activation fully opens the gate Continuous activation holds gate open MAN OPEN overrides Anti Tail gate ATG Reclose Timer and all controls but MAN STOP Activation fully closes the gate Continuous activation holds gate closed MAN CLOSE overrides all controls but MAN STOP MAN OPEN and FIRE De activation stops opening and closing gates MAN STOP overrides Reclose Timer and all other controls manual or automatic If MAN STOP is disconnected from its COMMON no commands affect the gate ENTRY SYSTEM FIRE SWITCH INPUTS TB9 CYCLE Reclose Timer OFF Activation opens the gate which remains open until another command is received A CYCLE command when the gate is fully open closes the gate This Alternate action allows a single c
15. ALLATION TOP VIEW Left Gate STREET Right Gate Center of Anchor Hinge COMPLEX Gate Operator Concrete Pad Figure 1 Gate Operator Layout Options NOTES 1242F5 Left Gate and Right Gate are determined by looking from inside the complex toward the street Figure 1 shows a typical Bi Parting gate in standard and compact installations Always install gate operators inside of the fence line NEVER on the public side of the fence Mount all manual controls and activating devices at least 6 ft away from the gate for safety Allow enough clearance around the gate and the gate operator for installation and service Rev C Doc 6001242 01 20273 5 of 53 B PAD AND MOUNT TO GATE Drive Shaft Center Covar Conduit Access Area 1 2 Dia Stud TOP VIEW SIDE VIEW 1242F6 Figure 2 Pad and Mount The concrete pad must be sufficient to support the gate operator and the dynamic forces created by the moving gate LiftMaster recommends a pad 24 wide by 27 long by 30 deep The operator must be level and parallel to the gate so the pad should be level and about 4 above grade to prevent water entrance Four anchor bolts are required to secure the gate operator to the pad The mounting holes in the gate operator are 5 8 in diameter Red Head bolts 77 x 372 are recommended Be sure to provide access for wiring conduits In Master Slave systems remember to include conduit stubs for se
16. E e FIRE SWITCH WIRING TERMINAL EXIT LOOP Lift head off BLOCKS lr EXIT pies pins COMMON Loosen screws Omya SHADOW Insert wires m 1 Tighten screws a Replace head SENSOR Leh on terminal J SHADOW LOOP pins 4 DETECTOR INSIDE INT LOOP DETECTOR See NOTE 2 SENSOR 2 SER SOR OUTSIDE INT OUTSIDE INT LOOP DETECTOR See NOTE 2 66 INTERRUPT oo EET BAR BAR TB POWER FAIL OPTION INPUT RADIO INPUT 24VAC 200mA POWER o rove RADO RECEIVER COMMON POWER INPUT MAGLOCK EM RELAY g OUTPUT ARTH FE _ ow POWER POWER MAGLOCK BATTERY VO PWR INPUT 1204F11 Figure 12 Control Board Wiring Remove the plastic control box cover See NOTES next page before proceeding Wire all external control devices to their connections on the control board as shown See Appendix A for details on how each control input affects the gate operator Connect the Master Slave interconnect cable see Part 3 Rev C Doc 6001242 01 20273 19 of 53 NOTES Disconnecting the STOP terminal from the COMMON terminal stops the gate and prevents all commands from having any effect Inside and Outside Interrupt Loops For safety and proper gate operation gate s must open toward the Inside Interrupt loop For maximum safety Inside and Outside Interrupt loops require separate loop detectors If only one loop detector is used the Outside loop must also
17. GATE SW 2000 B1 Control Board Fire Manual uts In errupt Bar Common Cycle Radio Interrupt Loops Shadow Loop swin gates only oop Common Interrupt Loops Er E y swing gates on xit Loop O Common Conduit See NOTES To Aux Device Light CCTV MagLock etc NOTES When parallel wiring the RADIO INPUT terminals do not connect the POWER output from one board to the POWER output on the other board Failure to observe this will damage both controller boards Do not parallel wire the MAGLOCK terminals Auxiliary device circuits may be damaged if separate auxiliary devices are used with each board Both gate operators must have the same settings for a Gate Setting Switch S1 b Reclose Timer Pot c Current Sensitivity pots Left amp Right Reverse Inrush d Limit Cams CAUTION The Signal and Common terminals on one board MUST connect to the corresponding Signal and Common terminals on the other board Failure to observe this will damage both controller boards DO NOT INTERCHANGE SIGNAL AND COMMON TERMINALS Rev C Doc 6001242 01 20273 49 of 53 APPENDIX C MODEL SW 2000 B1 PARTS LIST 1242F7 ITEM PART NAME WHAT IT DOES Contains control board input connections Control Board not shown Controls gate operator functions Main power switch resets gate operator Reduces motor speed to drive gate Transmits motor power to gearbox 6 ACMotr Provides drive to gate operator
18. I O INPUT TB1 SLAVE I O Input output terminals are used to control a second gate operator in a Master Slave system ADJUSTMENTS OVERLOAD Factory set pot protects the gate operator from excessive motor current R71 If RETRY is ON when the limit is exceeded a closing gate reverses a few inches and stops and an opening gate stops waits 30 second then tries to resume The gate will retry twice before faulting out NOTE Gate may be more sensitive to drag in one direction than the other NOTE For swing gate operation controls are Right Clockwise and Left Counterclockwise REVERSE Adjustable pot controls gate sensitivity to blockages by the instantaneous RIGHT R78 rise in motor current If RETRY is ON when the limit is exceeded a closing gate opens fully and an opening gate stops waits 30 seconds then tries to resume The gate will retry twice before faulting out REVERSE Adjustable pot controls gate sensitivity to blockages by the instantaneous LEFT R81 rise in motor current If RETRY is ON when the limit is exceeded a closing gate opens fully and an opening gate stops waits 30 seconds then tries to resume The gate will retry twice before faulting out NOTE LiftMaster gate operators have two reverse sense adjustments left and right where other gate operators have only one This allows greater flexibility of installation For instance you can install a gate on an incline and not worry about sacrificing downhill gate s
19. IGHT SHADOW LOOP MTRLEFT MTR RIGHT MOTOR INSIDE OO OO LEFT RIGHT INSIDE INT INDICATORS FUNCTIONAL INPUT O OVERLOAD INDICATORS di ADJUST RIGHT LEFT REVERSE OVERLOAD LEFTRIGHT INRUSH ADJUST D E 2 CE 33693 INRUSH INTERRUPT ADJUST BAR ICOMMON INTERRUP eck TB11 OUTSIDE INT RADIO INPUT POWER RELAY COMMON f N LI TB4 8 zz 5 5 nm LLLI MAGLOCK BATTERY V O PWR INPUT MOTOR POWER N 1204F12B Rev C Doc 6001242 01 20273 43 of 53 NTROLS SWITCH 1 OFF ON DIP SWITCH 44 of 53 SLIDE ACTION When used with ATG this switch controls several gate operator features S1 1 Inside Interrupt Loop four different modes are selectable SLIDE and ATG OFF Loop activation prevents the gate from opening or closing If gate is moving Loop activation stops the gate When the Loop clears the gate resumes its course SLIDE only ON Loop activation prevents the gate from closing If gate is closing Loop activation opens the gate and starts the Reclose Timer if timer is on ATG only ON Loop activation prevents the gate from opening or closing If gate is closing a Loop activation stops the gate When the Loop clears the gate resumes closing If the gate is opening or fully open as soon as the Loop clears the gate immediately begins closing to discourage tailgaters SLIDE and ATG ON Loop activation prevents
20. INSTALLATION AND OPERATION INSTRUCTIONS FOR TH MODEL SW SWING GATE OPERATOR C68 BOARD TABLE OF CONTENTS Rev C Doc 6001242 01 20273 1 of 53 The LiftMaster Model SW 2000 B1 2 of 53 Dynamic motor braking limits gate overtravel Separated arm segment joints reduce the risk of injury to users Alternate action OPEN CLOSE inputs Manual switch inputs override other commands Adjustable reclose timer Gate lock relay can be used for electromagnetic locks and CCTV cameras or lights Master slave operation for two operators on bi part gates and vehicle trap gates Selectable anti tailgate function prevents two cars from entering on one open command Senses obstructions through adjustable Peak motor current senses Open Motor detection indicates when the motor is not drawing any current Two separate peak motor current sense adjustments for reversing direction or stopping one for clockwise motion and the other for counterclockwise motion Initial inrush current sense adjustment offsets initial inrush current to the motor Automatic fault Re Try causes the gate operator to retry an operation twice following a fault condition Selectable Automatic Gate Closure feature closes the gate when power is restored after an outage unless gate is at open limit Two 115 VAC accessory plugs provided 24 VAC accessory power provided 80 1 worm gear reduction Output torque limiter prevents damage to the ga
21. N 2 Park a car while it is running on the Shadow Loop but clear of the Interrupt Loop 3 Activate an open command and verify that the gate does not open CAUTION f the gate begins to open move the car immediately 4 Remove the car from the Shadow Loop and verify that an open command opens the gate NOTE In a Bi Parting Master Slave system BOTH gates must be at either the fully open or fully closed limit for the Shadow loop input to be effective 11 Interrupt Bar While the gate is opening push on the Interrupt Bar The gate should stop 12 Maglock Verify that the maglock activates when the gate is fully closed 13 Automatic Gate Closure 1 To automatically close a fully open gate after power is restored on switch S1 set TIMER to ON Open the gate fully then cycle the unit power switch to verify Automatic Gate Closure operation 14 Power Fail Option 3 Verify that switch S3 Power Fail Open Direction switch is set to the desired position Figure 4 4 Record switch S3 setting in the space provided in the Maintenance Section It is essential that maintenance personnel know what the gate will do when power is turned off during maintenance 22 of 53 Doc 6001242 01 20273 Rev C N FINAL ASSEMBLY OF GATE OPERATOR Swing Arm ASSy Swing Arm Gate bod Fs um over Clear n place Mounting Bolt and perdio plastic n piace Locking Nut Cover Figure 13 Gate Operator Final Assem
22. PUTS Unit System System System Bi Select ATG Timer and or Retry from the Master unit and set Slave ATG Timer and Retry to OFF Otherwise the ATG ON shorter Reclose Timer Retry ON in either unit supersedes the other O For safe and reliable operation this setting MUST be the same for both units see Appendix A Inputs affect both gate operators so you may connect inputs to either unit Rev C Doc 6001242 01 20273 27 of 53 2 BI PARTING LATCH GATE DETAILS The Bi Parting Latch Gate is typically used in low traffic residential sites due to its ease of use and added security of magnetic locking The Bi Parting Latch configuration can consist of any combination of models SL 1000 B1 slide gate SW 2000 B1 swing gate and BG 3000 B1 barrier gate SWITCH S1 SETTINGS Slide Unit niis i SWITCH S1 SETTINGS Option Mac Exit Loop Slide Unit Retry Sys Option pun Timer OFF ATG Sys Tied Inte ups Retry OFF Option oop ATG OFF Master ON Trap OFF Gate Master OFF Operator Trap OFF Slave Master Slave Cable Slave Gale For safety setting MUST be the same for both units Outside Interrupt Connect MagLock to one unit only Loop STREET Figure 17 Typical Bi Parting Latch Gate Installation HOW IT WORKS e The Master moves first during opening and Slave first during closing with a 2 second delay between them to prevent gate intercollision and to ensure proper latching W
23. TION NOTES Rev C Doc 6001242 01 20273 7 of 53 PART 2 SYSTEM INSTALLATION A MOUNTING GATE OPERATOR WARNING For safety reasons the Power Fail Operation Option is shipped with the battery unconnnected to the system Do not connect the battery until all other installation and alignment procedures have been completed Failure to observe this warning may result in the Power Fail Operation Option moving the gate at unexpected moments To avoid injury always turn off the unit power switch before working on gate Loosen the large mounting bolt and remove the Swing Arm Cap assembly Remove 4 protective bolts holding the cover on lift off the cover and set aside Remove the assembly kit and parts Remove the 4 bolts that attach the gate operator to the shipping pallet Mount gate operator on the cement pad using the previously installed anchors Be sure the operator mounting is level and square and that the gate operator control box faces away from the gate Connect the power conduit into the switch box Reinstall the Swing Arm Cap assembly and finger tighten the large mounting bolt B CONNECTING POWER CAUTION Ensure that the AC power circuit breaker is turned off before wiring power to the switchbox Run power cables through the conduit to Gate Operator then connect wires to the switch box as shown in Figure 3 1 Wire nut the hot black wire to the black pig tail 2 Wire nut the neutral white wire to the white pig
24. ame time TRAP TANDEM only one gate outside gate BI PARTING LATCH opens at a time SIS Open one gate lags by 2 seconds OUTSIDE 1204F18 Figure 14 Master Slave Gate Configurations e Inthe Master Slave configuration one Master unit controls one Slave unit e Master and Slave units communicate at 9600 baud via a 4 wire interconnection cable 24 of 53 Doc 6001242 01 20273 Rev C C MASTER SLAVE WIRING Connecting Master and Slave units is fast and easy e Master Slave connections are made through the SLAVE I O terminal block TB1 located at the top right corner of the gate operator controller board see Figure 15 below Connect the Receive inputs RECV1 RECV2 on each board to the Transmit inputs XMIT1 XMIT2 on the other board To prevent cross talk between Master Slave wires and power or input wires use shielded cable or run the Master Slave wires in a separate conduit Use two 18 14 AWG twisted pair wires or a shielded cable containing 2 twisted pair wires for Master Slave Interconnection To ensure a reliable communication between Master and Slave units the maximum allowable wire length is 3000 feet NOTE Be sure to connect the two units correctly Improper wiring of the Master Slave inter connection prevents proper operation of the system TO MASTER OR SLAVE UNIT both wired the same TO XMIT 2 TO RECV 1 OUTSIDE INSIDE INTERRUPT SENSE INTERRUPT SENSE SHADOW SENSE EXIT SENSE WIRING TB15 TB12 TB1
25. aster unit Reclose Timer if enabled does not start counting down until the Slave unit is fully closed Since ATG is not allowed in the Master unit if the Reclose Timer is not enabled the Master gate will remain open During high traffic hours the slower moving Master gate can be latched open by a continuous Manual Open input leaving the faster moving Slave gate to control entering and exiting traffic If a vehicle stalls between the gates and they close they can be opened by a CYCLE or RADIO command or by driving over the Slave unit Inside Interrupt Loop SLIDE ON only or optional Exit Loop A fault in one unit affects both units see Troubleshooting Maintenance for Fault List Doc 6001242 01 20273 31 of 53 e continuous FIRE input in either gate opens both gates and holds them open e continuous Manual STOP in either gate stops both gates There are 2 different ways to close the gate after entering or exiting 1 Reclose Timer When the Reclose Timer expires the gates close automatically Master or Slave 2 ATG and Interrupt Loop When ATG is ON clearing the Inside Interrupt Loop causes the gate to close Slave unit only INPUT CONNECTIONS for more details refer to Part 2 Paragraph L Connecting Input Wiring MASTER UNIT SWITCH S1 SETTINGS AND INPUTS Gate SLIDE Reclose Operator Unit Unit Unit SLAVE UNIT SWITCH S1 SETTINGS AND INPUTS Unit Unit Unit Unit Master and Slave units can have differe
26. ate will open left right TO LEFT RIGHT SWITCH S3 POWER FAIL Selects the direction the power fail operation option will move the gate left right LEFT RIGHT if AC power fails INDICATORS NOTE For swing gate operation controls are Right Clockwise and Left Counterclockwise LED indicators light when controls and inputs are active Additional indicators are as follows LEFT LIMIT Indicates that the LEFT limit switch is activated RIGHT LIMIT Indicates that the RIGHT limit switch is activated MTR LEFT Indicates that the gate is moving counterclockwise MTR RIGHT Indicates that the gate is moving clockwise XMIT Indicates data is being sent to the other unit in a Master Slave system RECV Indicates data is being received from the other unit in a Master Slave system Doc 6001242 01 20273 Rev C TIMER FAULT MAX RUN TIME REVERSE OVERLOAD OPEN MTR FUNCTIONAL INPUTS Indicates the Reclose Timer is running Timer is set at pot R94 Indicates a fault in the system See Fault List in Part 5 Troubleshooting and Maintenance Indicates the motor ran for more than 75 seconds without reaching a limit switch and was stopped Usually requires mechanical service See Fault List in Part 5 Troubleshooting and Maintenance Indicates the peak motor current threshold was reached See Fault List in Part 5 Troubleshooting and Maintenance Indicates that the average motor current threshold was reached See Fault List in Part
27. bly IMPORTANT SAFETY PROCEDURE If switch S3 Power Fail Open Direction switch is set to OPEN the gate cycle the gate to its fully open position before performing step 1 If switch S3 Power Fail Open Direction switch is set to CLOSE the gate cycle the gate to its fully closed position before performing step 1 Turn off power to the gate operator at the circuit breaker and wait for one minute Disconnect Drag Link from Anchor then loosen mounting bolt and remove Swing Arm Cap Assembly and Drag Link Assembly from drive shaft Set this assembly aside Install clear cover on gate operator control box Make sure that gate operator unit power switch is turned on Install gate operator cover and secure with four bolts Replace Swing Arm Cap Assembly and Drag Link Assembly on drive shaft then reconnect Drag Link to gate Anchor Tighten mounting bolt on Swing Arm Cap Assembly into the countersunk hole in the drive shaft then tighten the locking nut Turn on power to the gate operator at the circuit breaker Cycle the gate to ensure it is operating properly Rev C Doc 6001242 01 20273 23 of 53 PART 3 MASTER SLAVE OPERATION A WHAT IS MASTER SLAVE OPERATION The easy way to understand master slave operation is by the computer terms smart and dumb e Smart machines are controlled by a computer or dedicated microprocessor such as microwave ovens and new style washing machines e Dumb machines are contro
28. ded end of Drag Link Assembly to Anchor and unwelded end to Swing Arm Doc 6001242 01 20273 11 of 53 H SETTING LIMIT CAMS The limit cams are adjusted by loosening the locking screws and rotating the cams The cams rotate with the swing arm shaft so small adjustments are magnified by the length of the gate The gate operator torque limiter allows the gate to be pushed or pulled a short distance a few inches only Use manual controls to move the gate during limit cam adjustment To avoid damage to the gate and gate operator due to the gate overrunning its limits perform the following steps carefully 1 SETTING RIGHT GATE LIMIT CAMS Top Limit Cam E Open Gate Bottom Limit Cam CE Closed Gate Top Limit Switch Bottom Limit Switch 1242F2 Figure 7 Setting Right Gate Limit Cam Make sure that switch S2 is set to the Left position Turn on gate operator power switch Using manual CLOSE and STOP move the gate to its proper closed limit position Loosen the locking screw on the bottom limit cam and turn the cam clockwise until it just barely closes the limit switch Retighten the limit cam locking screw Using manual OPEN and STOP move the gate to its proper open limit position Loosen the locking screw on the top limit cam and turn the cam counterclockwise until it just barely closes the limit switch Retighten the limit cam locking screw Open and close the gate to check the limit cam settings If required
29. e operator For safe and reliable operation this setting MUST be the same for both units see Appendix A SLAVE UNIT SWITCH S1 SETTINGS AND INPUTS Gate SLIDE Reclose Operator Unit System System System Bi Parting Option Option Option Option Systeme Bi Parting Unit System System System Optione Option O Option O Option O OFF OFF Systeme Unit Unit Unit Unit Unit Unit Unit Select ATG Timer and or Retry if desired from the Master unit and set Slave ATG Timer and Retry to OFF Oooo 26 of 53 Otherwise the ATG ON shorter Reclose rss ON in either unit supersedes the other Master and Slave units can have different settings nputs affect both gate operators so connect to one unit only Inputs affect one gate operator only so connect inputs separately to each gate operator For safe and reliable operation this setting MUST be the same for both units see Appendix A Doc 6001242 01 20273 Rev C E MASTER SLAVE INSTALLATION DETAILS 1 BI PARTING GATE DETAILS The simple Bi Parting Gate is typically used in low traffic residential sites due to its ease of use The Bi Parting configuration can consist of any combination of models SL 1000 B1 slide gate SW 2000 B1 swing gate and BG 3000 B1 barrier gate INPUTS SWITCH S1 oe SETTINGS Slide Unit SWITCH 91 Option Shadow Loop SETTINGS Timer Sys Fire Exit Loop Slide Unit ORN MagLock Timer OFF Manual Inp
30. e speed of an rotary object Sprocket A toothed wheel which transfers power via a chain Thermal overload A condition at which a heat producing device shuts off automatically when it reaches a critical and damaging temperature level Torque A force that causes rotation Torque Limiter A clutch like mechanism used to relieve excessive torque generated by the gate on the gate operator Doc 6001242 01 20273 51 of 53 52 of 53 NOTICE TO CANADIAN USERS NOTICE The Industry Canada label identifies certified equipment This certification means that the equipment meets telecommunications network protective operation and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document s The Department does not guarantee the equipment to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Us
31. ensitivity INRUSH Adjustable pot controls the delay in sensitivity to a reverse sense input R119 This delay in sensitivity prevents the initial motor inrush current from causing a fault condition The weight of the gate determines this setting RECLOSE Adjustable pot controls the time delay between gate reaching full open and TIMER R94 starting to reclose The Reclose Timer is adjustable from 0 250 seconds Doc 6001242 01 20273 47 of 53 CONNECTORS LIMIT SWITCH J4 Connector for the left right limit switch cable BATTERY I O J11 Connector for use by the Power Fail Operation unit PWR INPUT J1 Connector for AC input power MOTOR POWER J3 Connector for the motor cable LOOP DETECTOR Connector for optional LiftMaster Outside Interrupt Loop detector J15 add on board LOOP DETECTOR Connector for optional LiftMaster Inside Interrupt Loop detector add J12 on board LOOP DETECTOR Connector for optional LiftMaster Shadow Loop detector add on J13 board LOOP DETECTOR Connector for optional LiftMaster Exit Loop detector add on board J14 48 of 53 Doc 6001242 01 20273 Rev C APPENDIX B PARALLEL GATE WIRING While it is strongly recommended that the Master Slave function be used in any dual unit installation two LiftMaster model SW 2000 B1 s may be parallel wired as Bi Parting gates only Entry Systems SW 2000 B1 Switches Control Board Cycle Radio Fire Manual Inputs Interrupt Bar O Common
32. ent flow varies with temperature Do not tune the sensitivity measurements too finely or they may change with the time of day or seasons For swing gate operation controls are Right Clockwise and Left Counterclockwise If your installation requires setting switch S2 the Open to Right position use the Open to Right adjustment procedures below If your installation requires setting S2 to the Open to Left position use the Open to Left adjustments following the Open to Right procedures The minimum sensitivity is full clockwise and maximum sensitivity is full counter clockwise These adjustments must be made while the gate is in motion Before starting the adjustments verify that the Overload pot is set to 3 00 o clock the Left and Right reverse pots are set fully clockwise and the Inrush pot is set to the 11 o clock position see Figure 9 Make all adjustments in the order listed EFT RIGHT CONTROL BOARD Figure 9 Gate Sensitivity Adjustments Location 1 LEFT GATE CLOCKWISE OPEN ADJUSTMENTS Right Reverse Adjustment R78 1 Initiate opening the gate 2 Wait 4 to 5 seconds then lightly tug against the edge of the gate to simulate an obstacle 3 If the gate does not stop reclose the gate and adjust the pot slightly counterclockwise 4 Repeat steps 1 3 until the gate stops when tugged and has the desired sensitivity Left Reverse Adjustment R81 Open the gate fully then initiate closing
33. ent should be reviewed with the owner and or end user of the automated gate system They should also be informed of the need to maintain control and safety equipment on a regular basis Safety equipment should be checked monthly to ensure it is working properly All installation manuals and safety information should be left with the owner Moving gates have pinch points and entrapment zones which can be extremely dangerous to pedestrians especially small children Doc 6001242 01 20273 3 of 53 BASIC INSTALLATION HINTS AND RULES PLEASE READ THIS SECTION CAREFULLY BEFORE BEGINNING YOUR INSTALLATION The sections that follow contain detailed procedures for installation of a model SW 2000 B1 system In addition to these specific procedures there are a number of general hints and rules which will help ensure that your installation will be done correctly and efficiently These are discussed below 1 UNDERSTAND THE SYSTEM AND INSTALLATION SITE THOROUGHLY The SW 2000 B1 is a flexible and reliable gate operator system but the quality of service depends directly on the quality of installation Please read these instructions carefully and study the applicable diagrams before planning your installation In particular understand any site characteristics that may affect the system installation WARNING INSTALL PERMANENT WIRING U L specifications require the SW 2000 B1 system to be permanently wired Refer to your local wiring code for
34. ers should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or an electrician as appropriate Doc 6001242 01 20273 Rev C CHAMBERLAIN LiftMaster PROFESSIONAL COPYRIGHTO 2001 ALL RIGHTS RESERVED This document is protected by copyright and may not be copied or adapted without the prior written consent of LiftMaster This documentation contains information proprietary to LiftMaster and such information may not be distributed without the prior written consent of LiftMaster The software and firmware included in the LiftMaster product as they relate to this documentation are also protected by copyright and contain information proprietary to LiftMaster FOR TECHNICAL SUPPORT TO ORDER REPAIR PARTS Call our toll free numbers Call our toll free numbers 800 323 2276 800 528 2806 800 998 9197 800 998 9197 Installation and service information is Prepare to provide the following available six days a week information when ordering repair parts e Part Number e Part Name Model Number
35. gate and the gate frame LED Light Emitting Diode LEDs are indicators placed on the controller board which light up to indicate an action in the system Limit switch A switch which its closure indicates the gate has reached its open or close limit causing the gate to stop There are two limit switches open and close Limit cam An object which its excursion corresponds to the gate traveling distance and closes the limit switch at the open or close limit of the gate Loop sensor A wire embedded in the ground for magnetically sensing large metallic objects cars Exit or Open Loop activation opens the gate v Interrupt or Reverse or Reopen Loop activation reverses or stops the gate Shadow Loop activation prevents a fully open or closed gate from moving while a vehicle is inside the arc of a swing gate Loop detector An electronic device that is activated by a loop sensor sensing a metallic object Master Slave A synchronized system containing a pair of gate operators Maglock An electric magnet which is used to secure the closed gate Power Fail Option A battery backup system which opens or closes the gate at power outage Pulley A grooved wheel which transfers power via a belt Reclose Timer An electronic timer which closes the fully open gate automatically Retry A condition at which the stopped gate resumes its course automatically after the occurrence of a Fault RPM Rotation Per Minute is a term to indicate th
36. hen the gates are fully closed the outer edge of the Master gate rests on the outer edge of the Slave e A fault in one unit affects both units see Troubleshooting Maintenance for Fault List e Acontinuous FIRE input in either gate opens the gates and holds them open There are 3 different ways to close the gates entering or exiting 1 Reclose Timer When the Reclose Timer expires gates close automatically 2 ATG and Interrupt Loop With ATG ON clearing the Inside Interrupt Loop closes the gates 3 Alternate Action With ATG and TIMER OFF RADIO or CYCLE commands close fully open gates WARNING The Power Fail Operation Option can be used ONLY on the Master Unit To maintain all gate functions during power outages use a full UPS Uninterruptable Power Supply on each unit INPUT CONNECTIONS for more details refer to paragraph L Connecting Input Wiring e Inputs can be connected to either gate For enhanced safety the Interrupt Bar Interrupt Loop and Shadow Loop inputs may be connected to both gates MASTER UNIT SWITCH S1 SETTINGS AND INPUTS Gate SLIDE Reclose Operator Bi Parting Unit System System System Option Option Option Option ON OFF Systeme SLAVE UNIT SWITCH S1 SETTINGS AND INPUTS Bi Parting Unit System System System Option Option Option O9 Option OFF OFF Systeme Select ATG Timer and or Retry from the Master unit and set Slave ATG Timer and Retry to OFF Otherwise the ATG ON shorter Rec
37. lation of a gate operator can result in a dangerous system Gate operators can present serious hazards to persons in the immediate area when not controlled in a safe manner Choose one or more controls which together will allow complete control of the gate Most importantly the gate must be able to be stopped at all times in case of emergency and the emergency control should be conveniently located clearly marked and visible All controls must be kept out of the reach of small children Serious injury or death can result from children playing with the controls All controls should be located so the person operating them can see the full area of gate movement Gate operators and associated control equipment should be installed by qualified professional installers who should observe the following safe installation procedures 1 Power should always be disconnected whenever installing wiring or servicing a gate operator Moving chains and belts in gate operators can catch clothing or fingers and cause severe injury Installation of wiring should comply with all local building and electrical codes 3 All manual gate locks should be disabled to avoid damage to the gate or gate operator should the lock become engaged after the operator is installed All operator controls and safety equipment should be tested at the conclusion of installation to be sure they are functioning properly The operation of the gate controls and safety equipm
38. lled by simple electronic or physical mechanisms like old style washing machines with their cams and timers When your installation requires using two gates together they can be controlled either by the dumb method of wiring them in parallel and using limit cams and reclose timers for control see Appendix B or the smart method of enabling the Master Slave programming built into the gate operators LiftMaster gate operators are capable of handling any gate combination you re likely to need and we strongly recommend using the smart method for the following reasons 1 Synchronization Gate actions opening closing etc are synchronized in Master Slave operation 2 Added safety A fault in one unit affects both units providing added safety to the system 3 Reduced wiring Inputs radio exit loops etc need be wired to only one unit in some Master Slave configurations 4 Simplified gate setting Gate controls ATG Reclose Timer etc only need to be set in one unit in some Master Slave configurations Let s take a quick look at some Master Slave gate configurations cover the wiring and setup procedures then go into the details of each type to help plan your installation B MASTER SLAVE GATE CONFIGURATIONS LiftMaster models SL 1000 B1 slide gate SW 2000 B1 swing gate and BG 3000 B1 barrier gate can be teamed as Master Slave systems in the following configurations INSIDE BI PARTING both gates open at s
39. lose Timer Retry ON in either unit supersedes the other For safe and reliable operation this setting MUST be the same for both units see Appendix A Inputs to one unit affect both gate operators so you can connect inputs to either unit 28 of 53 Doc 6001242 01 20273 Rev C 3 TRAP GATE DETAILS Rev C The Trap gate is typically used in secured sites for screening incoming and or outgoing traffic In the Trap configuration only one gate opens at a time trapping the vehicle between gates Due to its ease of use Slide gates are most popular for the Trap configuration The Trap configuration can consist of any LiftMaster model for Master and a model SL 1000 B1 slide gate or BG 3000 B1 barrier gate for Slave NOTE The SW 2000 B1 swing gate may not be used for Slave SWITCH S1 SETTINGS JTS COMPLEX Slide Unit Option Timer Unit Option ned Unit ATO ON Master ON Inside Interrupt Trap ON Loop Operator Shadow Loop swing gate only Master Gate SWITCH S1 Outside Interrupt SLAVE SETTINGS JTS Loop Slide Unit Option Timer Unit Option Master OFF Trap OFF Inside Interrupt Loop Outside Interrupt V Affects both units Loop STREET Figure 18 Typical Trap Gate Installation HOW IT WORKS e n normal operation one gate must completely close before the other opens so only one gate is open at atime As soon as one gate closes the second gate automatically opens If the second
40. loses and a closing gate resumes its course INSIDE INTERRUPT LOOP with SLIDE OFF and ATG OFF Gate fully open or closed activation prevents the gate from moving Gate opening or closing activation halts the gate When the Interrupt Loop clears the gate resumes its course INSIDE INTERRUPT LOOP with SLIDE ON and ATG ON Gate fully open or closed activation prevents the gate from closing When the Interrupt loop clears the gate begins closing Gate opening or closing activation halts a closing gate When the Interrupt Loop clears an opening gate closes and a closing gate resumes its course INSIDE INTERRUPT LOOP with SLIDE ON and ATG OFF Gate fully open or closed activation prevents the gate from closing only Gate opening or closing activation fully opens a closing gate and starts the Reclose Timer if timer is ON OUTSIDE INTERRUPT LOOP with ATG OFF Gate fully open or closed activation prevents the gate from closing only Gate opening or closing activation fully opens the closing gate and starts the Reclose Timer if timer is ON OUTSIDE INTERRUPT LOOP with ATG ON Gate fully open or closed activation prevents the gate from closing only Gate opening or closing activation prevents the gate from closing When the interrupt loop clears the gate begins closing INTERRUPT BAR INPUTS TB11 INTERRUPT BAR Activation fully opens a closing gate and stops an opening gate If RETRY is ON the gate wait
41. lt condition slightly adjust the pot clockwise Repeat steps 6 and 7 until the gate cycles without a fault and has the desired sensitivity Rev C Doc 6001242 01 20273 15 of 53 J SETTING GATE CONTROL SWITCH S1 AND RECLOSE TIMER POT R94 NOTE For complete details on controls indicators adjustments and inputs see Appendix A 1 GATE CONTROL SWITCH 1 SLIDE ACTION 51 1 RETRY 51 3 51 4 51 5 51 6 16 of 53 SLIDE ACTION TIMER RETRY ATG MASTER CONTROL BOARD Figure 10 Gate Control Switch S1 Location When used with ATG this switch controls several gate operator features Inside Interrupt Loop four different modes are selectable SLIDE and ATG OFF Loop activation prevents the gate from opening or closing If gate is moving Loop activation stops the gate When the Loop clears the gate resumes its course SLIDE only ON Loop activation prevents the gate from closing If gate is closing Loop activation opens the gate and starts the Reclose Timer if timer is on ATG only ON Loop activation prevents the gate from opening or closing If gate is closing a Loop activation stops the gate When the Loop clears the gate resumes closing If the gate is opening or fully open as soon as the Loop clears the gate immediately begins closing to discourage tailgaters SLIDE and ATG ON Loop activation prevents the gate from closing When the Loop clears the gate resumes
42. ly a bump to the opening and closing gate and verify that the gate stops or reverses Inrush Gate response time Apply a bump to the gate as it initiates opening and closing and verify that the gate 20 of 53 responds to the bump within a second Doc 6001242 01 20273 Rev C Maximum Retry Count If you want the gate to resume operation automatically up to 2 times 30 seconds after a Fault set RETRY on switch S1 to ON If you do not want the gate to resume automatically after a Fault set RETRY on switch S1 5 OFF Give the opening gate a quick bump to generate a fault and verify retry operation Entry inputs Activate the CYCLE input entry system RADIO input radio transmitter and EXIT Loop input driving over the exit loop and verify that they fully open the gate If Reclose Timer is ON it will close the gate Activate the FIRE input fire department switch and verify that the gate fully opens and then closes immediately If Reclose Timer is ON it will close the gate Alternate Action If you want the CYCLE input Entry system or RADIO input Transmitter to both open and close the gate on switch S1 set TIMER to OFF and ATG to OFF Activate the CYCLE command wait until the gate is fully open then activate the CYCLE command again The gate should close verifying Alternate Action operation Note If you select Alternate Action you cannot use ATG ON and TIMER ON in procedure
43. nal Assembly of Gate Operator Doc 6001242 01 20273 41 of 53 The following table was provided to help you keep a record of the maintenance schedule Write the inspection date the left hand box and check the boxes across as you perform your maintenance procedures MAINTENANCE SCHEDULE TABLE Torque Limit ulleys Gear Zontro Fire Gate Lr s 2 Sense 42 of 53 Doc 6001242 01 20273 Rev C APPENDIX A SYSTEM OPERATION REFERENCE CONTROLS INDICATORS INPUTS AND ADJUSTMENTS For control and indicator locations refer to the figure below For detailed explanations of the Gate Operator s various controls indicators inputs and adjustments refer to the pages that follow SENTEX LOOP DETECTOR INDICATORS TB1 OUTSIDE INSIDE INTERRUPT SENSE INTERRUPT SENSE SHADOW SENS EXIT SENSE OUTSIDE INSIDE anon Map BaF ToS OO MASTER SLAVE INTERRUPT ae DETECTOR DETECTOR DETECTOR INDICATORS RIGH POWER ON INDICATOR 1 HOLIMS MANUAL CONTROLS a ACTION RE TRY IMANUAL MAI NU ATG CONTROLS INPUT 3 RECLOSE TIMER ADJUST SWITCH S1 ar MAX RUN TIME GATE OPERATOR CYCLE REVERSE STATUS O INDICATORS COMMON OVERLOAD FIRE FIRE TB9 DIRECTION SWITCH S2 Z CYCLE UP CJL POWER FAIL EXIT O SWITCH S3 POWER FAIL GATE OPEN TO LEFT RIGHT LEFT R
44. nect your wires remove the head from the correct terminals and open the screws Insert the wire into the correct opening on the front and tighten the screw until the wire is held firmly When you have made all connections for a given head plug it back onto the pins designated for that terminal block Stranded wire must be between 16 and 24 awg Solid wire must be between 18 and 24 awg This is the total thickness measurement so if you are putting two wires in the combined thickness must fall within this range NEVER try to insert more than two wires per terminal 6 ENSURE GOOD CONNECTIONS A light tug on the wire will tell you if the connection is secure When reconnecting system components make sure all pins are straight on chips connectors and terminal block heads 7 READ THE MARKINGS CAREFULLY The connection points are marked on the boards clearly Before making any connection be sure to read the marking and check it against the corresponding figure in these instructions so that you understand the connection you are making 8 TRAIN YOUR CUSTOMERS THOROUGHLY Although customer responsibility is limited to proper installation the quality of service is determined by the care of system setup Ensure that the customer has a copy of this manual to guide them It will save you and them lots of inconvenience and aggravation later 4 of 53 Doc 6001242 01 20273 Rev C PART 1 SITE PREPARATION A LOCATION AND LAYOUT STANDARD INST
45. ng Arm Gate Mounting Bolt and operator Locking Nut cover Cover mounting bolt 4 places Figure 20 Gate Operator Disassembly and Assembly Gate Operator Serial Number Power Fail Option Yes No One minute after a power outage the Power Fail Option Opens Gate Closes Gate If switch S3 Power Fail Open Direction switch is set to open the gate cycle the gate to its fully open position before performing step 1 If switch S3 Power Fail Open Direction switch is set to close the gate cycle the gate to its fully closed position before performing step 1 Refer to Figure 20 above to perform the following instructions Turn off power to the gate operator at the circuit breaker and wait for one minute Inspect Gate Arm Swing Arm Cap Assembly Swing Arm and Drag Link Assembly for wear and hardware tightness Check its box in the Maintenance Schedule Disconnect Drag Link from Anchor then loosen mounting bolt and remove Swing Arm Cap Assembly and Drag Link Assembly from drive shaft Set this assembly aside Push and pull the Gate to ensure it swings freely grease if necessary Check its box in the Maintenance Schedule Remove the cover mounting bolts and remove the gate operator cover Reinstall the Drag Link Swing Arm and Swing Arm Cap Assemblies Perform preventive maintenance tasks 3 to 15 After completing all checks perform the procedure found in Part 2 System Installation paragraph N Fi
46. nsion with chain tensioner Do not oil chain Sprocket must not be loose in the shaft Tighten set screws if loose 9 Torque limiter must not slip factory setting is 75 ft lb Tighten set screws if loose 9 Limit switches contacts must bounce back rapidly when they are pressed and released Belt Check for wear and tension 25 to 30 Ib Adjust the AC motor up or down to set proper tension Pulleys must all line up and be firmly secured to their shafts Tighten set screws if loose Gear Box Check for no oil leakage around the bushings Do not oil gearbox Control board Check for water damage or burned spots All connectors secured to the board Wiring Check all wirings for any insulation damage Check for loose wire connections No Rust Check for rust throughout the unit Check corners for water entrapment Fire Open Activate Fire department switch to verify emergency gate opening Gate Sense Check for the gate sensitivity refer to Part 2 System Installation paragraph Gate Sensitivity Adjustments Power Fail Option Check for proper operation refer to Part 2 System Installation paragraph K Power Fail Option Connection item B Power Fail Option Operation Test NOTES To prevent loosening two set screws are used in each hole and LOCTITE threadlocker 242 is applied Doc 6001242 01 20273 Rev C Rev C PREVENTIVE MAINTENANCE INSTRUCTIONS Swing Arm Cap ASSy Swi
47. nt settings Exit Radio Cycle Fire and Manual Stop inputs affect both gate operators so connect inputs to one unit only 32 of 53 Doc 6001242 01 20273 Rev C PART 4 MODEL SW 2000 B1 OPTIONS A LIFTMASTER LOOP DETECTOR BOARDS The model SW 2000 B1 has connectors for four LiftMaster supplied loop detector add on boards These boards interface with Interrupt Shadow and Exit loop sensors which simply plug into the control board The add on boards can be ordered pre installed or can be installed in existing model SW 2000 B1 units B POWER FAIL OPERATION OPTION The LiftMaster Power Fail Operation Option may be ordered pre installed in new units or can be purchased separately for installation in LiftMaster gate operator systems in the field The Power Fail kit includes a DC motor belt battery battery support bracket assembly includes bracket 3 control relays rectifier and wire harness and mounting hardware Features of the Power Fail Option are as follows e The Power Fail Operation system fully opens or closes the the gate User s choice one minute after a power outage The gate will remain open or closed until AC power is restored e When AC power is restored the battery is charged up to its full potenial then continuously trickle charged Recharging takes from one to five hours depending on the weight of the gate and how far it moved during the outage The age of the battery also increases the battery charging time
48. omentarily Normally the Close limit switch and Maglock LED s are on if the gate is fully closed and Open limit switch and Reclose Timer LED s are on if the gate is fully open The Power ON and Manual STOP LED s are always on Low input AC voltage The voltage across connector J3 pins 1 red wire and 3 white wire on the Control Board must measure 100VAC to 130VAC CAUTION HIGH VOLTAGE Measure with care Fault Causes Refer to the end of troubleshooting section 1 OPERATOR IS DEAD When the unit power switch is cycled no LED turns on The main circuit breaker is off The unit power switch is off The input power connector is not connected securely to the Control Board Low input AC voltage Bad Control Board 2 OPERATOR DOES NOT RUN When the unit power switch is cycled LED s blink simultaneously or turn on randomly 1 Low input AC voltage 2 The processor was installed improperly into Control Board by the installer 3 Bad Control Board When the unit power switch is cycled all LED s turn on and off except Power On at the same time On Manual Input Terminal TB2 the STOP terminals disconnected from the COMMON terminal An input is continuously activated Stuck Low input AC voltage Bad Control Board When the unit power switch is cycled all LED s except Power On turn on at the same time and off one after another with the bottom LED turning off first normal power up 1 input is continuo
49. ommand to both open and close the gate CYCLE also opens a closing gate If Anti Tailgating ATG is ON Alternate Action is disabled With ATG ON the gate begins closing as soon as the INTERRUPT LOOP clears Reclose Timer ON FIRE Activation opens the gate then the Reclose Timer closes the gate A CYCLE command also opens a closing gate but will not close a fully open gate if the Reclose Timer is ON If Anti Tailgating ATG is ON the gate closes as soon as the INTERRUPT LOOP clears Activation opens the gate Continuous activation holds the gate open If Reclose Timer is OFF when FIRE is deactivated gate closes immediately If Reclose Timer is ON when FIRE is deacitvated the Reclose Timer starts FIRE overrides all commands but Manual STOP EXIT LOOP SHADOW LOOP DETECTOR INPUTS TB10 EXIT LOOP Rev C Same as CYCLE but does not close the gate when it is fully open Doc 6001242 01 20273 45 of 53 SHADOW LOOP Activation prevents the gate from opening or closing so the gate won t hit a vehicle If the gate is already moving or if the gate is not fully opened or closed this input has no effect INSIDE OUTSIDE INTERRUPT LOOP DETECTOR TB16 INSIDE INTERRUPT LOOP with SLIDE OFF and ATG ON Gate fully open or closed activation prevents the gate from moving When the Interrupt loop clears the gate begins closing Gate opening or closing activation halts the gate When the Interrupt Loop clears an opening gate c
50. on Because the battery may not be fully charged at the time of the test we strongly suggest moving the gate only one foot when performing the power fail test Set Power Fail switch S3 to the same position as switch S2 Figure 4 Turn on gate operator power switch Using the manual controls Figure 5 initiate gate opening then stop the gate about one foot short of its fully open position Turn off main power to the gate operator After about one minute the gate should start opening and stop at its fully open limit Turn on main power to the gate operator Set Power Fail switch S3 to the opposite position Using the manual controls initiate gate closing then stop the gate about one foot short of its fully closed position Turn off main power to the gate operator After about one minute the gate should start closing and stop at its fully closed limit Turn on main power to the gate operator 10 Set Power Fail switch S3 to the direction you desire the gate to move after a power outage Doc 6001242 01 20273 Rev C L CONNECTING INPUT WIRING TO MASTER SLAVE both wired the same TO XMIT 2 TO RECV 1 SENSOR sca ini be TO XMIT 1 TORECV2 OUTSIDE INSIDE INTERRUPT SENSE INTERRUPT SENSE SHADOW SENSE FXIT SENSE OUTSIDE INSIDE INTERRUPT RIGHT 8 LEFT LIMIT OFF S1 ON SLIDE ACTION Er TIMER Er RETRY Era re LI MASTER MANUAL CONTROLS See NOTE 1 ENTRY STE SYSTEM s COMMON FIR
51. otor wires or thermal overload 6 Limit switch staying closed when gate is supposed to move caused by a broken V belt defective limit switch or defective cams Faults 1 2 and 3 may be cleared at any time by the following if Fault Re Try is ON e All open commands Open Radio Exit Fire e Manual commands Open Close Stop Faults 1 2 and 3 may be cleared at any time by the following if Fault Re Try is OFF e Fire command e Manual commands Open Close Stop e All other commands must wait 60 seconds to clear these faults Faults 4 5 and 6 may be cleared at any time by the following e All open commands Open Radio Exit Fire e Manual commands Open Close Stop 38 of 53 Doc 6001242 01 20273 Rev C C FAULTS AND THEIR CAUSES 1 IF FAULT AND OVERLOAD LED S ARE TURNED ON OVERLOAD adjustment is set too low factory setting is at 3 00 o clock position Bad Control board Bad motor 2 IF FAULT AND REVERSE LED S ARE TURNED ON REVERSE or INRUSH adjustment is set too low The gate is blocked by an object Cold weather frozen motor or frozen gate hinges The Maglock does not disengage from the gate at the start of gate opening Power Fail option was installed without readjusting the gate sensitivity adjustments A sudden increase in input power Bad Control board Belt is too tight 3 IF MAX RUN TIME LED IS TURNED ON ONLY Limit cams do not engage the limit switches The belt or chain has been
52. p detector 3 Bad connection between the loop sensor loop detector and the Control Board Rev C Doc 6001242 01 20273 37 of 53 26 SHADOW LOOP IS INEFFECTIVE The gate is not at either the open or close limit Bad loop sensor or loop detector Bad connection between the loop sensor loop detector and the Control Board Only one gate is on the limit Master Slave systems only 27 MAGLOCK DOES NOT WORK Bad connection between Maglock its power supply and the Control Board Bad Control Board relay on the Control Board does not close Bad Maglock or Maglock power supply Large gap between gates 28 MASTER SLAVE SYSTEM Units work as stand alone 1 Miswired or disconnected Master Slave interconnect cable 2 Improper Master Slave switch S1 setting 3 Bad control board Units are not synchronized Improper switch S1 Master Slave settings One gate braking to stop causes a fault in the other moving gate 1 Both units are wired to the same circuit breaker 2 Undersized power wires B FAULT LIST The following conditions can cause a fault in the SW 2000 B1 gate operator system Interrupt Bar activation Average motor overcurrent overload caused by excessive motor current 1 2 3 Instantaneous motor overcurrent left right reverse sense due to an impact on the gate 4 Maximum motor run time exceeding 75 seconds 5 Inoperative motor caused by an open motor winding broken or unconnnected input m
53. parate inputs if any and for the Master Slave connection cable between gate operators NOTE Shading indicates conduit stub access areas INSTALLATION NOTES 6 of 53 Doc 6001242 01 20273 Rev C C POWER WIRING Provide a separate conduit stub for the AC power Each gate operator requires a 115 VAC 20 AMP single phase circuit NOTE Master and Slave units each require separate circuits to prevent false overcurrent faults Be sure to pull a ground wire in the conduit for the connection to the gate operator Do not rely on metallic conduit for earth ground D LOOP DETECTORS The gate operator has a shelf that can support non LiftMaster loop detector electronics Power for the loop detector can come from the auxiliary 115 VAC plugs in the gate operator or from the 24 VAC provided by the gate operator control board Conduit provisions should be made for the loop wire entrance to the loop detector The shelf space provided is approximately 4 x 10 x 5 high Shelf space on systems without the Power Fail Operation Option is about 10 x 10 x 5 NOTE Optional LiftMaster supplied loop detector add on boards are available both pre installed and for installation in the field See Part 4 SW 2000 B1 Options E OTHER CONNECTIONS Provisions should be made for conduit entrance into the gate operator for Master Slave wiring and external activating devices such as key switches telephone entry systems etc INSTALLA
54. readjust the limit cams until they are set properly 12 of 53 Doc 6001242 01 20273 Rev C 2 SETTING LEFT GATE LIMIT CAMS Top Limit Cam E Closed Gate Bottom Limit Cam Top Limit Switch Bottom Limit Switch Figure 8 Setting Left Gate Limit Cam Make sure that switch S2 is set to the Right position Turn on gate operator power switch Using manual OPEN and STOP move the gate to its proper open limit position Loosen the locking screw on the bottom limit cam and turn the cam clockwise until it just barely closes the limit switch Retighten the limit cam locking screw Using manual CLOSE and STOP move the gate to its proper closed limit position Loosen the locking screw on the top limit cam and turn the cam counterclockwise until it just barely closes the limit switch Retighten the limit cam locking screw Open and close the gate to check the limit cam settings If required readjust the limit cams until they are set properly Rev C Doc 6001242 01 20273 13 of 53 l GATE SENSITIVITY ADJUSTMENTS The gate operator monitors both average and peak motor current When the gate encounters an obstruction the gate operator senses the change in motor current and stops or reverses the gate Three sensitivity adjustments must be set in the field e Right gate motion R78 e Left gate motion R81 e Inrush current R119 NOTES The Overload adjustment R71 is factory set Do not adjust Curr
55. s 30 seconds then tries to resume The gate will re try twice before faulting out If the Interrupt Bar remains active for more than 30 seconds the gate will not retry 46 of 53 Doc 6001242 01 20273 Rev C Rev C INS OUTS INT SENSE SHADOW SENSE EXIT SENSE TB12 TB13 TB14 TB15 INPUTS INSIDE Input from an Inside Interrupt loop provides the signal for an optional LiftMaster INTERRUPT loop detector add on board Operation is the same as the Interrupt Loop SENSE input above OUTSIDE Input from an Outside Interrupt loop provides the signal for an optional INTERRUPT LiftMaster loop detector add on board Operation is the same as the Interrupt SENSE Loop input above SHADOW Input from shadow loop provides signal for optional LiftMaster loop detector SENSE add on board Operation is the same as Shadow Loop input above EXIT Input from exit loop provides signal for optional LiftMaster loop detector add on SENSE board Operation is the same as Exit Loop input above RADIO INPUT TB6 RADIO RECV Convenience terminals provide power 24VAC 200mA and signal connection for a radio receiver Activation is the same as CYCLE MAG LOCK INPUT TB4 MAG LOCK NO and COM inputs can close a circuit i e MagLock when the Close Limit switch is activated the gate is fully closed NC and COM inputs close a circuit security camera camcorder light etc when the Close Limit switch is deactivated when gate is not fully closed SLAVE
56. s 8 and 9 that follow Reclose Timer If you want a fully open gate to automatically close after a period of time on switch 51 set TIMER to ON and adjust Reclose Timer pot R94 to set the time period If you don t want the gate to close automatically on switch S1 set TIMER to OFF Activate any entry command except Manual OPEN to open the gate and verify the Reclose Timer operation NOTE Reclose Timer is not functional when the Manual Open command is used Inside Interrupt Loop and ATG when exiting If you want the gate to stop when a vehicle drives onto the Interrupt Loop and to restart when the vehicle drives off the Interrupt Loop on switch S1 set SLIDE and ATG to OFF If you want the gate to stop when a vehicle drives onto the Interrupt Loop and to close when the vehicle drives off the Interrupt Loop on switch S1 set SLIDE to OFF and ATG to ON If you want a closing gate to open when a vehicle drives on the Interrupt Loop on switch S1 set SLIDE to ON and ATG to OFF If you want a closing gate to stop when a vehicle drives on the Interrupt Loop and an opening or closing gate to close when the vehicle drives off the Interrupt Loop on switch S1 set SLIDE and ATG to ON Activate the CYCLE command drive over the Interrupt Loop and verify its operation Rev C Doc 6001242 01 20273 21 of 53 10 Shadow Loop 1 Ensure the gate is fully closed the close limit switch and Maglock LED s will be O
57. specific information WARNING Damage caused by faulty wiring is not covered by warranty 3 GROUND THE SYSTEM The system contains parts which may be damaged by static discharge A proper earth ground connected to the gate operator housing see Figure 3 will significantly reduce the chances of damage or improper operation The shielding in the cables specified for all remote sensors and controls should also be connected to earth ground at the controller end of the cable only To be effective the ground connection must be made by running 12 awg copper wire to a good ground point e g an electrical panel a metallic cold water pipe that runs into the earth or a grounding rod at least 10 feet in length that is driven into the earth within 12 feet of the system Even if you have a good earth ground you should try to discharge any static before handling the circuit boards WARNING Damage caused by static discharge and lightning is not covered by warranty 4 PROVIDE POWER FROM A DEDICATED SOURCE The outlet into which you connect the Gate Operator should be wired to its own circuit breaker This will reduce the line noise introduced into system power and minimize the risk of having other equipment interrupt system operation In a Master Slave system Master and Slave must each have separate circuits 5 DO NOT OVERLOAD THE TERMINAL BLOCKS The terminal blocks used in the gate operator are removable and the pins are soldered into the boards To con
58. t the gate 10 of 53 Doc 6001242 01 20273 Rev C Rev C GATE ARM INSTALLATION Hinge to Anchor STREET Gate Centerline 3 Center of Anchor Hinge Gate Gate dM Sto W Anch lt Mounting Bolt Plate and Locking Nut Spherical Rod End Assy ink Pine Anchor side Locking Nut Link Wedge Drag Link Pipe welded for security All dimensions are measured from one pivot point to the next pivot point The dimensions shown above are only recommended settings Your installation may require different dimensions The SW 2000 B1 can be installed without welding The anchor swing arm and drag link may be attached using the supplied hardware only may be welded or bolted and welded Paint or other anti rust coating must be applied to the cut areas of the swing arm and or drag link pipe to prevent rust Figure 6 Gate Arm Installation Attach gate anchor to gate by welding or using hardware not supplied Using manual controls move the swing arm cap assembly until it points roughly to the anchor as shown in Figure 6 Measure and cut the swing arm to length Attach swing arm to swing arm cap assembly with gate stop on driveway side using supplied hardware or by welding WARNING Installing gate stop on the wrong side will cause damage to the gate operator Measure and cut Drag Link pipe to length then insert spherical rod end assembly into pipe and tighten locking nut Attach wel
59. tail 3 Wire nut the ground green wire to the green pig tail 4 Dress all wiring inside the switch box and install cover Figure 3 AC Wiring 8 of 53 Doc 6001242 01 20273 Rev C RUNNING INPUT WIRING 1 Remove the plastic control box cover 2 Run wires from input components and Master Slave conduits into control box 3 For Master Slave wiring refer to Part 3 Master Slave Operation WARNING Route but do not connect input wires at this time If inputs are connected now the gate operator may activate at random during installation potentially injuring installation personnel SETTING GATE OPEN DIRECTION SWITCHES S2 AND 53 POWER FAIL GATE OPEN TO LEFT RIGHT LEFT RIGHT 7 CONTROL BOARD 1204F14 Figure 4 Gate Direction Power Fail Option Switch Location NOTE For swing gate operation controls are Right Clockwise and Left Counterclockwise 1 Gate opening direction is set by switch S2 located on the control board The switch is sensed only on power up so it should be set when the power is off 2 Ensuring power is off set switch S2 to the left for a Right Gate or to the right for a Left Gate If the system was ordered with the Power Fail Operation option 3 The power failure gate opening direction is set by switch S3 located next to switch S2 on the control board Set switch S3 left for clockwise or right for counterclockwise opening Rev C POWER UP PROCEDURE
60. te operator caused by force pushing against the gate Handles any gate weight up to 1000 pounds and length up to 18 feet Diagnostic LEDs on controller board indicate gate operator actions and assist in troubleshooting Power Fail Operation option automatically opens or closes the gate user s choice if AC power fails Optional loop detector add on boards plug into the controller board for Interrupts shadow and exit loops Inside and outside Interrupt Loops enhance gate control and distinguish between entering and exiting traffic Optional cover access door provides easy access to the control box 15 Lbs Accessory Kit Doc 6001242 01 20273 The LiftMaster model SW 2000 B1 Swing Gate Operator is a full featured commercial gate operator with a master slave wiring capability The SW 2000 B1 contains the following features DIMENSIONS WEIGHT ELECTRICAL 24 159 Lbs 115 VAC Single Phase 60 Hz 8 amp 20 172 Lbs with Power A separate 20 AMP circuit is 23 Fail Operation option required by most codes Rev C Rev C SAFETY SUMMARY It is important for everyone involved in the installation and operation of the LiftMaster model SW 2000 B1 Swing Gate Operator reads the following warnings WARNING A vehicle gate is a large heavy object that is moved by an electric motor A moving gate can cause serious injury or death The safety and well being of others depends on the installation of a safe system Improper instal
61. the gate Wait 4 to 5 seconds then lightly bump the leading edge of the gate to simulate an obstacle If the gate does not stop or back up reopen the gate and adjust the pot slightly counterclockwise Repeat steps 1 3 until the gate stops or backs up when bumped and has the desired sensitivity 14 of 53 Doc 6001242 01 20273 Rev C 2 RIGHT GATE COUNTERCLOCKWISE OPEN ADJUSTMENTS Left Reverse Adjustment R81 1 Initiate opening the gate 2 Wait 4 to 5 seconds then lightly tug against the edge of the gate to simulate an obstacle 3 If the gate does not stop reclose the gate and adjust the pot slightly counterclockwise 4 Repeat steps 1 3 until the gate stops when tugged and has the desired sensitivity Right Reverse Adjustment R78 Open the gate fully then initiate closing the gate Wait 4 to 5 seconds then lightly bump the leading edge of the gate to simulate an obstacle If the gate does not stop or back up reopen the gate and adjust the pot slightly counterclockwise Repeat steps 1 3 until the gate stops or backs up when bumped and has the desired sensitivity 3 INRUSH CURRENT ADJUSTMENT R119 Turn the pot fully counterclockwise Initiate opening the gate If the gate stops due to a fault condition slightly adjust the pot clockwise Repeat steps 2 and 3 until the gate cycles without a fault Open the gate fully then initiate closing the gate If the gate stops or backs up due to a fau
62. usly activated stuck 2 Both limit switches are stuck closed 3 Stalled motor 34 of 53 Doc 6001242 01 20273 Rev C 3 MOTOR DOES NOT RUN Motor is dead 1 The resettable motor thermal overload switch has popped 2 The interconnecting cable between the motor and the control board is disconnected 3 Bad control board 4 Bad motor Motor is stalled 1 Frozen motor gearbox or gate 2 V belt is too tight 4 THE CONTROL BOARD RESETS RIGHT AFTER GATE STARTS MOVING Low AC voltage Inadequate and undersized power wiring between the main circuit breaker and the gate operator 5 GATE STOPS IMMEDIATELY AFTER IT STARTS A Fault has occured Mostly in cold weather or mornings 2 A Fault has occured Inrush pot adjustment is set too low Power Fail Option was installed recently Gate sensitivity adjustments were not reset after installation of the Power Fail Option A Fault has occured 6 GATE STOPS A FEW SECONDS AFTER IT STARTS 1 Stuck limit switch Limit cams overrun the limit switches prior to gate movement due to loose torque limiter A Fault has occured 7 GATE STOPS WHILE OPENING OR REVERSES WHILE CLOSING A Fault has occured 8 OPENING GATE STOPS WHEN A VEHICLE APPROACHES THE GATE SLIDE ACTION on switch S1 is set to OFF causing the Interrupt loop to stop the gate 9 GATE OPENS BUT DOES NOT CLOSE Reclose Timer is OFF One of the inputs is continuously activated
63. uts Inside Interrupt ry OFF Loop ATG OFF Gate Master ON Shadow Loop Trap OFF Master Slave Master Slave Cable Fence Master Gate Slave Gate For safety setting MUST be the same for both units Outside Interrupt Connect MagLock to one unit only Loop STREET Figure 16 Typical Bi Parting Gate Installation HOW IT WORKS e The gates in a Bi Parting configuration are mirror images of each another and act identically e A fault in one unit affects both units see Troubleshooting Maintenance for Fault List continuous FIRE input in either gate opens the gates and holds them open There are 3 different ways to close the gates entering or exiting 1 Reclose Timer When the Reclose Timer expires gates close automatically 2 ATG and Interrupt Loop With ATG ON clearing the Inside Interrupt Loop closes the gates 3 Alternate Action With ATG and TIMER OFF RADIO or CYCLE commands will close fully opened gates INPUT CONNECTIONS for more details refer to paragraph L Connecting Input Wiring e Inputs can be connected to either gate but do not need to be connected to both However for enhanced safety the Interrupt Bar Interrupt Loop and Shadow Loop inputs may be connected to both gates MASTER UNIT SWITCH S1 SETTINGS AND INPUTS Gate SLIDE Reclose Operator Unit System System System Bi Parting Option Option Option Optione ON ON Systeme SLAVE UNIT SWITCH 1 SETTINGS AND IN