Home

Broan 64000 Ventilation Hood User Manual

image

Contents

1. V05520 SCREW NO 8 x 3 8 T B NO 8 HEAD V00613 SCREW NO 10 32 x 3 8 TE GREEN sd o
2. each sides as shown below Use two 2 2 inch wide strips for 30 wide hoods and four 4 2 inch wide strips for wider hoods cut to length See below for wood filler strip locations LOCATIONS WIDTHS A B 4 114 HD0079 3 INSTALL BACKSPLASH OPTIONAL Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting Screws In order to be able to install the backsplash make sure you have at least 18 clearance between bottom of hood and range control panel or cooktop See instructions packed with backsplash 4 SELECT BLOWER OPTION EXTERIOR OR INTERIOR INTERIOR BLOWER Follow all subsequent steps of this manual EXTERIOR BLOWER Refer to instructions packed with exterior blower and follow steps 6 10 12 and up of the present manual 6 5 CHOOSE THE OPENING INTERIOR BLOWER Remove the knockout for the chosen opening horizontal at the back of the hood or vertical on rough in plate See pictures below CAUTION When using P5 blower remove the 10 wide knockout smaller part If using P8 blower remove the knockout corresponding to the ducting installed 10 or 14 14 KNOCKOUT 6 INSTALL THE ROUGH IN PLATE ALL BLOWERS INTERIOR BLOWER Secure the rough in plate provided with the P5 and P8 blower inside the hood with four 4 lock nuts See picture below EXTERIOR OR IN LINE BLOWER Purchase Model 332KR separately Refe
3. from state to state or province to another This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone LLC at one of the addresses or telephone number stated below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 Broan NuTone Canada Inc 1140 Tristar Drive Mississauga ON L5T 1H9 1 888 882 7626 SERVICE PARTS 64000 Series HL0002 KEY QTY hood width 06750 BROAN ELITE LOGO 02264 SOCKET LAMP 02773 MALE 02772 FEMALE V03435 THERMOSTAT V03436 THERMOSTAT BRACKET V03501 SPEED CONTROLLER 03507 SPST SINGLE SWITCH FOR WARMING LAMP V03502 SPST DOUBLE SWITCH FOR HALOGEN LIGHT 03503 SPST LIGHTED SINGLE SWITCH FOR BLOWER V03504 SPEED CONTROL BUTTON V03505 TERMINAL STRIP 03517 10 POWER CORDS V03518 10 CORDS FOR HEAT LAMP V03519 10 CONTROL WIRE 03520 10 LIGHTED SWITCH WIRE 00673 LOCK NUT NO 8 32 02512 SCREW NO 8 32 x 1 2 QUADREX V01869 MACHINE SCREW NO 6 32 x 1 4 V01582 LOCK NUT NO 6 32 V00606 SCREW 8 3 8 NO 8 HEAD V03509 RANGEMASTER FILTER 8 930 x 9 800 V03510 RANGEMASTE
4. hood During construction or renovation cover the hood to make sure no dust sticks to stainless steel surface Avoid when choosing a detergent Any cleaners that contain bleach will attack stainless steel Any products containing chloride fluoride iodide bromide will deteriorate surfaces rapidly Any combustible products used for cleaning such as acetone alcohol ether benzol etc are highly explosive and should never be used close to a range Enamel finish Clean with warm water and mild detergent only When discoloration occurs use a good enamel polish such as auto motive polish DO NOT use rough abrasive cleaner or porcelain cleaner 16 OPERATION Always turn your hood on before you begin cooking to establish an air flow in the kitchen Let the blower run for a few minutes to clear the air after you turn off the range This will help keep the whole kitchen cleaner and brighter 0028 1 Warming lamp switches 2 Halogen light switches 3 ON OFF blower switch 4 Blower speed control BLOWER The blower is operated using two 2 controls Use the red lighted on off switch to start and stop the blower When turned on the blower will operate at the previous setting of the speed control Turn the speed control knob clockwise to decrease blower speed counterclockwise to increase speed COOKTOP LIGHTING HALOGEN A double set of ON OFF switches controls the halogen lights The front rocker control
5. to prevent backdrafting Follow the heating equipment manufacturers guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors Do not use this unit with any additional solid state speed control device To reduce the risk of fire use only steel ductwork This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a b d Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn hood ON when cooking at high heat or when cooking flaming foods Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter Use proper pan size Always use cookware appropriate for the size of the surface element AA WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS IF THE FLAMES DO NOT GO OUT IMMEDIATELY EVACUATE AND CALL THE FIRE DEPARTMENT NEV
6. 1705 MOTOR MOUNT V11614 WIRE NO 18 TEW BROWN x 10 V01927 METRIC SCREW M4 x 6MM PAN QDRX V03495 STRAIN RELIEF FOR BLOWER POWER CORD V03494 36 BLOWER POWER CORD V13230 OUTLET BOX COVER V03496 POWER CORD 120 VOLTS V00660 STRAIN RELIEF FOR POWER CORD V05520 SCREW NO 8 x 3 8 T B NO 8 HEAD DO NJ 2 a a a a a V00613 SCREW NO 10 32 x 3 8 TE GREEN 15 SERVICE PARTS DUAL BLOWER ROUGH IN Model P8 PART NUMBER V14971 DESCRIPTION ADAPTER AND DAMPER x 14 V13296 V03500 ADAPTER AND DAMPER x 10 AIR DEFLECTOR V14975 DUAL BLOWER ROUGH IN PLATE ASSEMBLY V03577 FOAM 1 2 x 1 2 x 12 V01582 LOCK NUT NO 6 32 V02160 CAPACITOR 15MFD V01857 WIRE COVER V01766 MOTOR 165W CW V03400 BLOWER IMPELLER HOOD 7 094 x 3 375 CW V14974 V01810 DUAL BLOWER ASSEMBLY IMPELLER RING V03399 BLOWER IMPELLER HOOD 7 094 x 3 375 CCW V03457 MOTOR 165W CCW V00871 WASHER 3 16 ID x 3 4 OD 01831 8 TIE WRAP V11705 MOTOR MOUNT V11614 WIRE NO 18 TEW BROWN x 10 V02001 MOTOR GROMMET G 431 1 V01927 V03495 METRIC SCREW M4 x 6MM PAN QDRX STRAIN RELIEF FOR BLOWER POWER CORD V03494 36 BLOWER POWER CORD V14960 OUTLET BOX COVER V00660 STRAIN RELIEF FOR POWER CORD V03496 POWER CORD 120 VOLTS
7. ER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels This could cause a violent steam explosion Use an extinguisher ONLY if A You own a Class ABC extinguisher and you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION 10 11 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it will be cooled down If the motor continues to shut off and restart have the hood serviced For best capture of cooking impurities the bottom of the hood should be at a minimum of 20 24 over a gas range and at a maximum of 30 above the cooking surface Two installers are recommended because of the large size and weight of this hood To reduce the risk of fire and to properly exhaust air be sure to duct air outside Do not exhaust air into spaces within walls or ceiling or into attics crawl space or garage This product is equipped with a thermostat which may start blower autom
8. ERIOR BLOWER TYPICAL RECTANGULAR DUCTWORK 7 OR 8 ROUND DUCTWORK Exterior blower 10 round duct In line blower A 20 minimum 20 minimum above above cooking cooking surface surface 24 for gas uoo 27 for gas MODEL 331H 332H 335 OR 336 MODEL HLB3 HLB6 HLB9 OR HLB11 EXTERIOR BLOWER TYPICAL DUCTWORK IN LINE BLOWER TYPICAL DUCTWORK 2 PREPARE THE INSTALLATION Make sure that the following items are included Range hood Accessories Filters Bag of parts including 4 lock nuts 1 wire clamp 8 1 2 double thread screws 2 wire connectors 2 1 2 standard screws 6 3 8 screws Parts sold separately Interior blower Model P5 includes blower rough in kit flow deviator and 3 x 10 adapter Interior blower Model P8 includes blower rough in kit flow deviator and x 10 adapter and x 14 adapter n line blower assembly HLB3 HLB6 HLB9 or HLB11 all include transition In line and exterior blower rough in plate model 332KR required for all In line or Exterior Blowers Exterior blower assembly 331H 332H 335 or 336 Halogen lights 120V 50W PAR 20 Heat lamps 120V IR 175W PAR 38 RMP Series Backsplash optional Baffle filters optional Transitions duct elbows dampers wall and roof caps Refer to pages 3 and 4 for a complete list of venting options and model numbers NOTE For cabinets with recessed bottom attach wood filler strips not included on
9. INSTALLATION INSTRUCTIONS BRSAN HB0056 64000 SERIES AINTENDED FOR DOMESTIC COOKING ONLY A READ AND SAVE THESE INSTRUCTIONS INSTALLER LEAVE THIS MANUAL TO HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 11 TO 13 Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 Broan NuTone Canada Inc 1140 Tristar Drive Mississauga ON L5T 1H9 1 888 882 7626 REGISTER YOUR PRODUCT ON LINE AT www broan com register V03515 rev J AA WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty Before servicing or cleaning unit switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards including fire rated construction codes and standards Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment
10. R FILTER 11 930 x 9 800 V13216 GREASE RAIL 30 V13217 GREASE RAIL 36 V13218 GREASE RAIL 42 V13219 GREASE RAIL 48 V03686 FILTER CLIP V02544 HALOGEN LAMP PAR 20 50W V03598 HEAT LAMP V03515 INSTALLATION GUIDE PARTS BAG 4 lock nut no 10 32 1 wire clamp LP16 AP 2 wire connectors no 74B 13278 8 double thread screw 6 12 x 0 5 6 8 x 3 8 screws 2 no 6 1 2 screws m m 2 m fafa 2 2 a 2 on lalh 001 4 41 41 41 1 414 41 41 41 41 41 41 41 41 101 I2 2 m 2 nom 2 no 2 2 nm 3 i I lol INJ o ro m J ro fafa a aso 410 00 410 00 4 14 J 14 SERVICE PARTS SINGLE BLOWER ROUGH IN Model P5 HL0021 QTY V13296 ADAPTER AND DAMPER x 10 V03500 AIR DEFLECTOR V12997 SINGLE BLOWER ROUGH IN PLATE ASSEMBLY V03577 FOAM 1 2 x 1 2 x 12 V02160 CAPACITOR 15MFD V01869 MACHINE SCREW NO 6 32 x 1 4 V01857 WIRE COVER V01582 LOCK NUT NO 6 32 V14973 SINGLE BLOWER ASSEMBLY V01810 IMPELLER RING V03400 BLOWER IMPELLER 7 094 x 3 375 CW V01766 MOTOR 165W CW col c a aa a 4 4 4 4 00871 WASHER 3 16 ID x 3 4 OD V02001 MOTOR GROMMET G 431 1 01831 8 TIE V1
11. Steel wall covering with warming shelves Optional HL0071 1 SELECT BLOWER OPTION AND INSTALL DUCTWORK Either an interior or exterior blower or in line blower may be used with this hood The Broan Elite 64000 Series must be installed with blower models P5 P8 HLB3 HLB6 HLB9 HLB11 331H 332H 335 or 336 only Other blowers cannot be substituted Blowers sold separately Plan where and how the ductwork will be installed If installing in line blower refer to instructions packed with in line blower and follow steps 1 up to 3 6 9 10 12 and up of this manual Install proper sized ductwork elbows and roof or wall cap for the type of blower you are installing If using 7 or 8 round ducts or 34 x 14 duct use a transition Use 2 duct tape to seal duct joints The minimum hood distance above cooktop must not be less than 20 for an electric range and 24 for a gas range A maximum of 30 above cooktop is highly recommended for best capture of cooking impurities Distances over 30 are at the installer and users discretion Roof cap Roof cap 3 x 14 to 8 7 or 8 transition if round duct 3 x 14 duct 3 x 10 to 7 3 x 10 or or 8 transition 3 x 14 duct Hood with Hood interior blower 20 minimum above tar minimum above cooking surface cooking surface 24 for gas 24 for gas MODEL P5 SINGLE OR MODEL P5 SINGLE OR P8 DOUBLE INTERIOR BLOWER P8 DOUBLE INT
12. atically To reduce the risk of injury and to prevent power from being switched on accidentally switch power off at service panel and lock or tag service panel Because of the high exhausting capacity of this hood you should make sure enough air is entering the house to replace exhausted air by opening a window close to or in the kitchen To reduce the risk of fire and electric shock the Broan Elite 64000 Series hood must be installed with Broan interior blower models P5 or P8 Broan exterior blower models 331H 332H 335 or 336 Broan in line blowers models HLB3 HLB6 HLBS9 HLB11 Other blowers cannot be substituted Blowers sold separately Use with approved cord connection kit only Please read specification label on product for further information and requirements 64000 SERIES RANGE HOOD SYSTEM INTERIOR BLOWERS Model 647 7 Rd wall cap Model 415 7 round adjustable elbow optional Model 407 7 round 2 ft sections Model 412 transition IND x 10 to 7 Standard duct x 10 Adapter and damper 3 x 10 supplied with P5 and P8 blowers Rough in kit supplied with P5 and P8 blowers Model P5 single blower 500 cfm RMP Series Backsplash Stainless Steel wall covering with warming shelves Optional HL0070 Model 634 or 644 Model 643 roof cap 8 Rd wall cap Model 418 10 round adjustable elbow optional 8 round s
13. ginal purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone LLC will at its option repair or replace without charge any product or part which is found to be defective under normal use and service This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone LLC faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states or provinces do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE LLC S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE LLC S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE LLC SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary
14. p 4 screws for 30 hood Remove wiring cover on top of the hood and connect wiring see instructions included with exterior or in line blower Place the hood under the cabinet and slide it in position Secure the hood by tightening the screws completely 10 CONNECT WIRING ALL BLOWERS AA WARNING Risk of electrical shock Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally INTERIOR BLOWER Connect cable into wiring box using wire connectors Connect wires as follow BLACK to BLACK WHITE to WHITE and GREEN or BARE wire under ground screw Reinstall wiring cover DO NOT FORGET TO CONNECT THE GROUND HD0007 1 Ground screw IN LINE OR EXTERIOR BLOWER Remove rough in plate wiring cover and connect wiring see instructions included witn in line or exterior blower 11 INSTALL THE BLOWER INTERIOR BLOWER The blower must be installed to the rough in plate using 4 3 8 screws for the single blower unit and 6 3 8 screws for the dual blower unit Remove the cover from the blower assembly Remove the impeller s by pulling them out gen tly see pictures below 11 INSTALL THE BLOWER INTERIOR BLOWER CONT D Install screws into the location as shown in the pictures below single blower or dual blower Do not tighten sc
15. r to instructions included with the rough in kit Secure the rough in plate inside the hood with 4 lock nuts 7 INSTALL THE DEVIATOR INTERIOR BLOWER YOU MUST install the deviator if you choose to vent the hood vertically Install the deviator as shown NOTE f installed correctly the deviator will protrude about 1 8 above the rough in plate Inserting deviator into hood vertical opening 8 INSTALL THE ADAPTER INTERIOR BLOWER Using two 2 standard 1 2 screws secure the adapter to the top or back of the hood Seal the adapter to the hood using duct tape HD0005 HD0006 d 9 INSTALL THE HOOD ALL BLOWERS INTERIOR BLOWER Run power cable to installation location Place the hood to its location Mark the position of the screws smaller part of the key holes with a pen Remove the hood and install the 8 1 2 double thread screws leaving a 1 8 gap 4 screws for 30 hood Remove wiring cover place the wire clamp insert the cable in the hood and tighten the wire clamp to secure the cable Place the hood under the cabinet and slide it in position Make sure the adapter damper assembly enters the ducting Secure the hood by tightening the screws completely EXTERIOR OR IN LINE BLOWER Run power cable to installation location Place the hood to its location Mark the position of the screws smaller part of the key holes with a pen Remove the hood and install the 8 1 2 double thread screws leaving a 1 8 ga
16. rews down fully leave a 1 8 gap Hang blower unit onto blower plate screws through the large part of the keyhole Slide the blower to its position screws in the small part of the keyhole Tighten the screws Single blower P5 Dual blower P8 Secure the blower by installing 2 more screws into the locations shown in the pictures below single blower or dual blower Reinstall impeller s and cover Single blower P5 FOR DUAL BLOWER UNIT MAKE SURE THE IMPELLERS ARE CORRECTLY INSTALLED THE HOOD WILL NOT WORK PROPERLY REVERSED Both impellers are different in the dual blower one rotates clockwise and the other counterclockwise Each wheel and motor have an arrow and a number on them you have to match them correctly see drawing beside AN WARNING Never plug the 2 prong blower cord to the 3 prong power supply cord Plug the power supply to the 3 prong male connector A F the blower unit into the 2 prong female receptacle B inside the hood 10 12 LIGHT BULBS This range hood uses 50W halogen lamps 120V 50W PAR 20 Install the lamps by rotating them clockwise into their socket holder 13 HEAT LAMPS The heat lamps required are 120V 175W max infrared bulbs 120V IR 175W PAR 38 White halogen lights can be used if warming shelves are not used 120V 90W PAR 38 Install the lamps by rotating them clockwise into their socket holder 14 INSTALL FILTERS I
17. s the center light for 42 and 48 hoods The rear rocker controls both side lights each switch controls one light for 30 and 36 hood Select one two or three lights for best cooking lighting Use PAR 20 50W halogen bulbs 12 16 OPERATION CONT D AA WARNING Never place highly flammable material under warming lamps WARMING LAMPS INFRARED Each warming lamp is controlled with its own ON OFF switch Use infrared light bulbs 120V IR175W PAR38 or white halogen bulbs 120V 90W PAR38 if food warming shelves are not used HEAT SENTRY This hood is equipped with a Heat Sentry thermostat This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface 1 If blower is OFF it turns blower ON to HIGH speed 2 If blower is ON at a lower speed setting it turns the blower up to HIGH speed Z WARNING The HEAT SENTRY can start the blower even if the hood is turned OFF In this case it is impossible to turn the blower OFF with blower switch If you must stop the blower do it from the main electrical panel When the temperature level drops to normal the blower will return to its original setting WARRANTY BROAN NUTONE LLC ONE YEAR LIMITED WARRANTY Broan NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of ori
18. t is recommended to install side filters first and finish with center one s Insert upper end of filter into the hood tab end Raise lower end toward the inside of hood Position lower end of filter into channel and pull on filter tab While pulling the filter tab slide the filter top under the inner retaining piece Boo Ns Baffle filters are available as an option see instruction sheet included with baffle filters HD0010 1 Tabs 15 USE AND CARE Grease filters and impeller s The grease filters impeller s and grease rail should be cleaned frequently Use a warm detergent solution Grease filters and impeller are dishwasher safe Remove filters by pushing filters towards the back of hood and rotating filters downward 11 15 USE AND CARE CONT D Hood cleaning Stainless steel cleaning How to maintain its BRIGHT LOOK Do Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original polish lines Always rinse well with clear water 2 or 3 times after cleaning Wipe dry completely You may also use a specialized household stainless steel cleaner Don t Do not use any steel or stainless steel wool or any other scrapers to remove stubborn dirt Do not use any harsh or abrasive cleansers Do not allow dirt to accumulate Do not let plaster dust or any other construction residues reach the
19. tandard duct Model 459 transition Model 413 x 14 to 8 transition LISA x 10 to 8 Duct x 14 Flow deviator vertical exhaust only 2 1 Adapter and damper 3 14 supplied with P8 blower 64000 SERIES HOOD Model P8 dual blower 900 cfm for use with 36 hoods or wider NOTE The dual blower P8 can be installed either with 3 x 14 or 314 x 10 ducts For optimal air and quiet sound performance use 3 x 14 ducts 64000 SERIES RANGE HOOD SYSTEM IN LINE AND EXTERIOR BLOWERS Model 437 759 10 Bd v il odel HLB9 800 Rd wall High capacity roof cap or HLB11 1 P aa Model 335 1200 cfm or 336 1500 cfm in line blower i Model 331H 600 exterior blower includes two 8 x 12 to or 332H 900 cfm 10 round transitions 27 exterior blower Model 441 1 10 Rd wall cap JZ Model HLB6 600 A gt we M d in line blower bor CEN M n _ includes two 412 x 18 2 to 10 round transitions 22 77 m Cem pi ai pp RA OO Model 421 Aa 10 Rd vert adjustable elbow Model HLB3 280 cfm optional for use with in line blower includes one 8 to 10 round transition exterior blowers Model 410 10 Rd duct 2ft sections 64000 SERIES HOOD 332KR in line and exterior blower rough in kit Purchase separately RMP Series Backsplash Stainless