1. 2 Connect the cable to the socket labeled 10V AC 1 under the unit For connector wiring see Section A 5 2 Power socket unit bottom page 34 Bosch Security Systems User Manual F 01U 252 722 V1 2011 12 16 en Installation NurseCall Relay Unit 3 2 6 Setting the jumpers on the communication board on the Relay Plus Unit 1 Disassemble the unit see Section 6 5 1 Disassembling the unit page 29 2 Remove the communication board see Section Removing the communication board page 29 3 Set the jumpers as required in your configuration By default the jumpers are set for connection to a Display Zettler Setting the jumpers for a Display Zettler pe un Dn a Setting the jumpers for a printer setup or a Display Norsk n yg TE 4 Assemble the communication board and the unit This is basically the reverse of the disassembling procedure see Section 6 5 1 Disassembling the unit page 29 F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems NurseCall Relay Unit Installation en 17 3 2 7 Connecting the RS 485 One NurseCall Main Unit and up to 32 NurseCall Relay Units can be connected to an RS 485 bus Please contact a specialist for a correct installation gt See Section A 5 4 RS 485 socket unit rear page 34 for connector wiring CAUTION Do not use a star connection for the RS 485 network Incorrect connection Main Unit
2. 1 Loudspeaker See Section 2 2 1 Loudspeaker page 10 2 Display See Section 2 2 2 Display page 10 3 Keyboard under the cover See Section 2 2 3 Keyboard page 10 4 LED Indicator 5 Yellow button Description en 7 Used to view more details about the event or alarm currently displayed date and time position etc 6 Green button Used to acknowledge an alarm locally see Section 5 2 3 The green button does not work page 27 7 Red button with light This button is not used Pressing the button does not activate a function The light blinks red during an alarm User Manual F 01U 252 722 V1 2011 12 8 en Description NurseCall Relay Unit 2 1 2 Bottom view 1 Identification label 2 Cable channels 3 Wall mounting holes distance between holes 157 mm See Section 3 2 3 Wall installation page 14 for a detailed description 4 ON OFF switch 5 LINE socket used for firmware update See Section A 5 1 LINE socket unit bottom page 34 for wiring 6 10V AC socket See Section A 5 2 Power socket unit bottom page 34 for wiring F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems NurseCall Relay Unit Description en 9 2 1 3 Front view 1 LED Indicator LED Standby mode normal operation Green permanent Backup battery low Green blinking Power suppl
3. Relay Unit 2 Relay Unit n Correct connection RS 485 bus 1 twisted pair cable 100 Q 100 Q At UC AT enx d GT CC VA NOTICE The NurseCall Main or Relay Units located at the two ends of the bus must be terminated with a 100 Ohm resistor Bosch Security Systems User Manual F 01U 252 722 Vi 2011 12 18 en Installation 3 2 8 3 2 9 NurseCall Relay Unit Connecting the RS 232 to the Relay Plus Unit gt Connect the printer or display device to the 9 pole SUB D connector 1 at the rear part of the housing of the Relay Plus Unit 1 0000o oo0oo0o0 For connector wiring see Section A 5 3 RS 232 socket Relay Plus Unit rear page 34 Setting the 100 Ohm termination jumper Within the NurseCall Main or Relay Units the RS 485 interface can be configured with a jumper 1 Disassemble the unit as described in Section 6 5 1 Disassembling the unit page 29 2 Remove the communication board as described in Section Removing the communication board page 29 3 Putthe 100 Ohm termination jumper J112 1 4 Assemble the communication board and the unit This is basically the reverse of the disassembling procedure see Section 6 5 1 Disassembling the unit page 29 NOTICE If you do not want to disassemble the NurseCall Relay Unit you also can short out pins 3 and 4 of the connector This has the same effect as the ju
4. 2 4 NurseCall Relay Unit Installation Generalities gt Install the NurseCall Relay Unit in a dry place away from any source of heat Tools required Torx T20 screwdriver Torx T10 screwdriver Installation on a piece of furniture It is recommended to place the NurseCall Relay Unit on a non slippery surface However do not place anything blanket or lace on top of the unit Wall installation You can fasten the NurseCall Relay Unit on a smooth wall surface using two screws The distance between holes is 157 mm The power line cord should be placed inside the cable channels on the bottom of the NurseCall Relay Unit Installing the antenna 1 Use the straight adapter 4 for wall installation or the right angled bended adapter 3 for installation on a piece of furniture 2 Fasten the adapter 3 or 4 on the antenna connector 1 oooga OOoOoO 3 Fasten the antenna 2 on the adapter F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems NurseCall Relay Unit Installation en 15 3 2 5 Connecting to the mains The NurseCall Relay Unit is powered by an adaptor 230 10 VAC or 115 10 VAC CAUTION In case of a different supply the equipment must fulfill isolation requirements according to EN60950 standard last edition 1 Plug the power adaptor into a power outlet placed near the unit It should be easily accessible at any time
5. 28 en Maintenance 6 6 1 6 2 6 3 NurseCall Relay Unit Maintenance Checking the system Check the correct function of your NurseCall system gt Perform periodically an alarm test Monitoring the power supply In case of a power failure the NurseCall Relay Unit emits a beep and the following message is displayed alternatively with the date and time display The backup battery ensures that the NurseCall Relay Unit remains operational even in the case of a power failure When fully charged the battery ensures a power backup of 24 hours When power returns after a power failure the battery is recharged If it has been completely discharged it will reach its full capacity after 24 hours of charging time Monitoring the backup battery The status of the battery is indicated on the top right of the display gt To check the backup battery voltage press i The following message is displayed NOTICE At startup an automatic check is made During normal operation an automatic check is made every 30 minutes gt If the remaining battery capacity drops below 25 the following message is displayed gt If the NurseCall Relay Unit detects that the backup battery is defective the following message is displayed NOTICE If the backup battery is defective replace it as described in Section 6 5 2 Backup battery replacing page 30 F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems Nurs
6. EU Directive 2002 96 EC The product and its accessories should be delivered to an appropriate collection facility that ensure recycling treatment and an environmentally compatible disposal This prevents any negative impact on the environment and human health and promotes the recycling of materials For more information on available collection facilities contact your local waste collection service or your local representative Disassembly Only authorized personnel are allowed to disassemble a NurseCall Relay Unit Returning to the manufacturer If there is no practical disposal place the NurseCall Relay Unit may be returned to your local representative Materials The NurseCall Relay Unit must be returned to an authorized point of recycling In order to protect people and environment the NurseCall Relay Unit must be recycled in an adequate manner Consequently all applicable laws and bylaws must be respected Battery NOTICE The battery should be disposed of as household waste Use a battery disposal facility when available gt Please check local regulations for disposal of batteries or call your local representative for information User Manual F 01U 252 722 V1 2011 12 32 en A 1 A 2 A 3 NurseCall Relay Unit Appendix Electrical specifications Voltage 230 or 115 10VAC Feary SB Dimensions and weight Casing dimensions Weight including antenna and power supply adaptor 740 Enviro
7. TRANSM 32 Acknowledgement Ack Transmitter No 32 NOTICE All events are buffered into the event buffer of the NurseCall Relay Unit All alarms and events are sent to the printer display All alarms and events except the events COMPUTER OFF and COMPUTER ON are sent to the Alarm management Software Bosch Security Systems User Manual F 01U 252 722 V1 2011 12 34 en NurseCall Relay Unit A 5 Connectors A 5 1 LINE socket unit bottom LINE socket Flash Data GND Not used Not used Not used Not used Flash Data IN OUT A 5 2 Power socket unit bottom 1 Not used 2 AC 1 10 12VAC 3 AC 2 4 GND A 5 3 RS 232 socket Relay Plus Unit rear 54321 O 0O 0 0 O OOOO 9876 om Am nm bar A 5 4 RS 485 socket unit rear RS 485 socket Relay output a RS485 A Termination RS485 A RS485 A when jumper end line is placed RS485 B Relay Output b 123456 F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems Bosch Security Systems Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Security Systems 2011
8. and messages are displayed NOTICE This user manual is written for the unit language English USA Certain displays may differ for the unit language English UK 2 2 3 Keyboard The keyboard has 21 alphanumeric keys They are used to perform special commands or during normal operation anan ABAD gg bh F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems NurseCall Relay Unit Description en 11 Access to the printer display setup Relay Plus Unit only See Section 4 4 Printer display setup on the Relay Plus Unit Page 22 Increase the volume of the loudspeaker See Section 5 1 Adjusting the loudspeaker volume page 25 Decrease the volume of the loudspeaker See Section 5 1 Adjusting the loudspeaker volume page 25 Scroll down to the previous alarm event See Section 5 2 Consulting the alarm or event buffer Page 25 Scroll up to the next alarm event See Section 5 2 Consulting the alarm or event buffer Page 25 Confirm a value or a command Cancel an entry or a command Check the status of the backup battery See Section 6 3 Monitoring the backup battery page 28 Enter a value such as special codes See Section 4 3 Special settings Page 21 Enter a value or launch the event alarm display mode See Section 5 2 1 Switching between alarm and event buffers indication Page 26 Lock and unlock the keyboard Bosch Security System
9. oO O O O CO N N N 10 10 10 10 12 12 13 13 13 14 14 14 14 14 15 16 17 18 18 19 19 19 19 19 19 19 20 20 20 20 F 01U 252 722 V1 2011 12 4 en Table of Contents 4 3 Special settings 4 3 1 Displaying the firmware version 4 3 2 Resetting all the parameters and buffers 4 3 3 Assistance and fire priority 4 3 4 Assistance and fire non priority 4 3 5 Special texts in German 4 3 6 Standard texts in German 4 4 Printer display setup on the Relay Plus Unit 4 4 1 Access to the printer display setup menu 4 4 2 Selection None 4 4 3 Selection Printer 4 4 4 Selection DISPLAY ZETTLER 4 4 5 Selection DISPLAY NORSK 5 Operation 51 Adjusting the loudspeaker volume 5 2 Consulting the alarm or event buffer TPA Switching between alarm and event buffers indication 5 2 2 Display indications BA The green button does not work 5 2 4 Disconnecting a Relay Unit 6 Maintenance 6 1 Checking the system 6 2 Monitoring the power supply 6 3 Monitoring the backup battery 6 4 Cleaning 6 5 Parts replacement 6 5 1 Disassembling the unit 6 5 2 Backup battery replacing 7 Disposal fol Disassembly s Returning to the manufacturer 7 3 Materials 1 4 Battery A Appendix A 1 Electrical specifications A 2 Dimensions and weight A 3 Environmental conditions A 4 List of criteria A 5 Connectors A 5 1 LINE socket unit bottom A 5 2 Power socket unit bottom A 5 3 RS 232 socket Relay Plus Unit
10. other than those authorized by the manufacturer of the NurseCall Relay Unit CAUTION It is mandatory to use the products specified in the present user manual to clean the NurseCall Relay Unit If you plan to use another product only do so after having obtained the authorization of the manufacturer DANGER The NurseCall Relay Unit contains highly sensitive electronic components It should be opened only in an ESD protected environment with respect to the following precautions 1 Discharge yourself from electrostatic loads by touching a grounded conductive surface before opening the unit 2 Avoid touching conductive parts inside the unit if not absolutely necessary CAUTION Never let any liquid enter the system In case of liquid spill inside the NurseCall Relay Unit act immediately as follows 1 Switch off the unit using the main switch under the casing Unplug the power supply adaptor Dry up the unit Clean the unit Check that the unit switches on correctly Observation and information In case of defective operation or any other technical incident for which no remedy is described in this manual please contact immediately your local representative F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems NurseCall Relay Unit 2 2 1 2 1 1 Bosch Security Systems Description General description Top view o O e G e e o a o a o o o o o H
11. rear A 5 4 RS 485 socket unit rear F 01U 252 722 V1 2011 12 User Manual NurseCall Relay Unit 21 21 21 21 22 22 22 22 22 23 23 23 24 25 25 25 26 26 2 2 28 28 28 28 29 29 29 30 31 31 31 31 31 32 32 32 32 33 34 34 34 34 34 Bosch Security Systems NurseCall Relay Unit 1 1 1 2 1 3 1 4 GP OO Bosch Security Systems Safety instructions en 5 Safety instructions NOTICE The user and installer should read and understand this chapter before any intervention on the NurseCall Relay Unit Importance of safety instructions Each safety and protection instruction in this manual must be adhered to in order to avoid personnel injuries property damages or environmental pollution In a similar manner the legal bylaws the measures in prevention of accidents and for the protection of the environment as well as the recognized technical rules aiming at appropriate and safe working conditions which as applied in the country and at the place of use of the NurseCall Relay Unit must be adhered to Disregarding safety rules Disregarding the safety rules as well as existing legal and technical regulations may lead to accidents to property damages or to environmental pollution Environmental conditions NOTICE The NurseCall Relay Unit must not be located near a water tap or any other source of water The electrical safety of the unit is only guaranteed if the electric
12. Call Main Unit Antenna The antenna is connected to the NurseCall Relay Unit using the adapter supplied with the unit gt See Section 3 2 4 Installing the antenna page 14 F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems NurseCall Relay Unit 3 3 1 3 1 1 Bosch Security Systems Installation en 13 Installation Unpacking The NurseCall Relay Unit is carefully packed for transportation The components contained in the box are protected but should be handled with care Store the packaging material for further use storage or transport 1 Take all components out of the box and place the NurseCall Relay Unit on the working space 2 Check each component in the box in accordance with the list of contents below 3 Check that the NurseCall Relay Unit and its accessories have not been damaged during transportation In case of defective or missing equipment do not try to install the NurseCall Relay Unit gt Contact immediately your local representative List of contents Description NurseCall Relay Unit Power supply adaptor Europe 230VAC 10VAC or Power supply adaptor UK 230VAC 10VAC UK or Power supply adaptor US 115VAC 10VAC Antenna 434MHz 1 2 L 34 cm FME Straight adapter BFME TNC Right angled bended adapter BFME ETNC 2 m Cable FCC 6 4 NurseCall Relay Unit User Manual User Manual F 01U 252 722 V1 2011 12 14 en Installation 3 2 3 2 1 3 2 2 3 2 3 3
13. NurseCall Relay Unit F 01U 252 722 V1 2011 12 BOSCH en User Manual NurseCall Relay Unit Table of Contents 1 1 1 2 1 3 1 4 1 4 1 2 1 2 1 1 2 1 2 2 1 3 2 1 4 2 1 5 22 221 2 2 2 2 2 3 2 2 4 2 2 9 3 1 3 1 1 3 2 3 2 1 3 2 2 32 3 3 2 4 3 2 9 3 2 6 Sef 3 2 8 S22 4 4 1 4 1 1 4 1 2 4 1 3 4 1 4 4 1 5 4 2 4 2 1 4 2 2 4 2 3 Safety instructions Importance of safety instructions Disregarding safety rules Environmental conditions General safety instructions Observation and information Description General description Top view Bottom view Front view Relay Unit rear view Relay Plus Unit rear view Detailed description Loudspeaker Display Keyboard RS 485 interface Antenna Installation Unpacking List of contents Installation Generalities Installation on a piece of furniture Wall installation Installing the antenna Connecting to the mains Setting the jumpers on the communication board on the Relay Plus Unit Connecting the RS 485 Connecting the RS 232 to the Relay Plus Unit Setting the 100 Ohm termination jumper Programming Generalities Using the keyboard Exit and cancel entries Key not allowed Locking and unlocking the keyboard Programming time out First use List of original factory settings Parameters set by the NurseCall Main Unit Locating mode and identification number Bosch Security Systems User Manual Table of Contents en 3 OO OO nn
14. al installation is conform to the national regulation and if this installation works properly The NurseCall Relay Unit may not be used in buildings prone to fire and explosion hazards NOTICE The NurseCall Relay Unit may not be used under exposure to the direct sunlight to heat to dust or to an excessive humidity only use the equipment in a clean environment gt Install the NurseCall Relay Unit in a dry place away from any source of heat CAUTION Interferences Avoid immediate proximity to other electric devices such as a television General safety instructions DANGER Electrocution During maintenance operations when the NurseCall Relay Unit is powered and its casing is removed it may not be left unattended CAUTION The NurseCall Relay Unit may only be connected to the electrical sources as described in Section A 1 Electrical specifications page 32 User Manual F 01U 252 722 V1 2011 12 6 en Safety instructions NurseCall Relay Unit 1 4 1 gt Pe D SG So CAUTION Maintenance and repairs may only be performed in conformance with the instructions and by authorized technical personnel only The sole possession of the user manual does not allow the personnel to perform any kind of repair on the NurseCall Relay Unit Take into account all the warnings and follow all the instructions displayed on the NurseCall Relay Unit and those which are printed in the documentation Never try to use replacement pieces
15. ast recent entry remains in the buffer The call for assistance replaces the call for help the reserve call and the technical call in the alarm buffer In addition to all the alarms all possible entries are stored in the event buffer The following messages are directly stored into the event buffer acknowledgement N46 sent by an N46 Wall Transmitter S35 or S37 Transmitters acknowledgement by S35 or S37 Transmitters local acknowledgement an acknowledgement at the NurseCall Main Unit or Relay Unit daily message check personnel arrival message A B C and D personnel departure message power outage of a receiver unit return of power at a receiver unit backup battery low of a receiver unit interruption of the RS 232 connection interface between the NurseCall system and a PC return of the RS 232 connection interface between the NurseCall system and a PC connection of a NurseCall Relay Unit to the RS 485 bus transmission of the event door by a RAC Wireless Contact NOTICE The alarm and event buffers have a capacity of 18 or 100 entries See the maximum number of events buffered in the NurseCall Main Unit user manual The event buffer will normally be filled with the last 18 or 100 entries In the alarm buffer only the active alarms are present User Manual F 01U 252 722 V1 2011 12 26 en Operation 5 2 1 5 2 2 NurseCall Relay Unit Switching between alarm a
16. at the top Ki oe i Ce Select a field with and _ change a value with CE and Confirm with ok Choose 0 to 9 characters for the criterion followed by O to 9 spaces Default values are 2 characters and 1 space 4 Repeat the operation for the floor 0 to 3 characters by default 2 characters the room 0 to 3 characters by default 3 characters the bed 0 or 1 character by default 1 character NOTICE Configuration of the display is possible only in display mode FL RO BE floor room bed If the NurseCall system is in display mode NUMBER there is no need of further programming F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems NurseCall Relay Unit 5 5 1 5 2 Bosch Security Systems Operation en 25 Operation Adjusting the loudspeaker volume When the NurseCall Relay Unit is in standby mode gt Press Be to increase the volume gt Press to decrease the volume Consulting the alarm or event buffer The NurseCall Relay Unit uses an alarm buffer and an event buffer for display indication The following alarms and messages are stored into the alarm buffer call for help call for assistance reserve call call for help 2 Technical call fire alarm battery low message error message disconnection of a NurseCall Relay Unit from the RS 485 bus If alarms are repeated only the le
17. eCall Relay Unit Maintenance en 29 6 4 Cleaning gt Avoid using cleaning products or detergents gt Wipe off your NurseCall Relay Unit occasionally with a dry cloth 6 5 Parts replacement 6 5 1 Disassembling the unit Removing the antenna 1 Remove the antenna 1 and its adapter 2 or 3 Removing the communication board DANGER Do not damage the battery cable its connector 7 or the serial communication board connectors 1 With a Torx T20 screwdriver unscrew and remove the 4 screws 4 2 With a Torx T10 screwdriver unscrew and remove the screw 5 3 Carefully remove the communication board 6 Bosch Security Systems User Manual F 01U 252 722 V1 2011 12 30 en Maintenance 6 5 2 NurseCall Relay Unit Backup battery replacing Important Safety Instructions The battery should charge for 24 hours before using the NurseCall Relay Unit for the first time after replacing the battery or after a long power shortage Battery type is 6V NiMH NOTICE The battery will charge correctly between 5 C 41 F and 45 C 113 F A battery that is new or that has not been used for a long time can have reduced capacity at first use A rechargeable battery can be charged and discharged many times However it will eventually wear out This is not a defect It is recommended to replace batteries that cannot ensure a minimum power back up time of 8 hours at full charge CAUTION May explode if ex
18. ing mode or the identification number 1 Type the code 194156 2 When the unit resets it plays a short melody and displays a temporary message 3 After afew seconds the unit goes back to the first use display 4 Select the locating mode and the identification number See Section 4 2 First use Assistance and fire priority This command sets the assistance call and the fire alarm as priority calls This means that alarms of these types will be displayed first 1 Type the code 123991 The unit plays a melody and a confirmation message is displayed User Manual F 01U 252 722 V1 2011 12 22 en Programming 4 3 4 4 3 5 4 3 6 4 4 4 4 1 NurseCall Relay Unit Assistance and fire non priority This command sets the assistance call and the fire alarm as non priority calls This means that the last alarm is displayed whatever its type This is the default value 1 Type the code 123992 The unit plays a melody and a confirmation message is displayed Special texts in German This command sets special texts in German The displayed criteria are BAD WC instead of TECHNIK HILFE 2 instead of NOTRUF2 1 Type the code 123007 The unit plays a melody and a confirmation message is displayed Standard texts in German This command sets standard texts in German This is the default value 1 Type the code 123008 The unit plays a melody and a confirmation message is displayed Printer display setup o
19. mper setting described above See Section A 5 4 RS 485 socket unit rear page 34 for connector wiring F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems NurseCall Relay Unit 4 4 1 4 1 1 4 1 2 4 1 3 4 1 4 4 1 5 Bosch Security Systems Programming en 19 Programming Generalities Using the keyboard gt Open the cover carefully and use the keyboard gt To access the special settings programming press lo three times quickly See Section 4 3 Special settings page 21 for more details Exit and cancel entries A gt Press C_ once or several times Key not allowed gt If you have pressed a key by mistake during the programming a high pitched beep is generated Locking and unlocking the keyboard gt Press ie o then A o within one second to lock or unlock the keyboard This function locks only the keyboard to prevent any false manipulation The colored buttons on the left hand side are still available When the keyboard is locked a small lock appears at the bottom right of the display Programming time out gt Programming of the NurseCall Relay Unit terminates automatically if no entries are made on the keyboard for more than one minute User Manual F 01U 252 722 V1 2011 12 20 en Programming 4 2 4 2 1 4 2 2 4 2 3 NurseCall Relay Unit First use List of original factory settings Parameter Original Factory Setting Printer display setu
20. n the Relay Plus Unit Access to the printer display setup menu NOTICE The printer display setup can only be configured on a NurseCall Relay Plus Unit connected to a NurseCall system via the RS 485 bus 1 Press ok then jX to access the programming menu ff K e if e 3 Press OK to enter the printer display setup Press d C to escape 4 Scroll with e and KN to select one of the following None Printer DISPLAY ZETTLER DISPLAY NORSK F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems NurseCall Relay Unit 4 4 2 4 4 3 4 4 4 Bosch Security Systems Programming en 23 Selection None gt if you have selected None press oK to confirm In this case there will be no printer display output This is the default setting Selection Printer gt if you have selected Printer press OK to confirm 1 Set the printing of all the daily messages sent by transmitters 2 Scroll with SE Ak and eo to select YES or NO Default value is YES 3 Confirm with OK Selection DISPLAY ZETTLER gt if you have selected DISPLAY ZETTLER press ox to confirm 1 Set the rotational display of alarms 2 Select YES or NO with CE and ES Default value is YES Confirm with ox 3 Set the display of the clock The format is HH MM 4 Scroll with oe and to select YES or NO Default value is YES 5 Confirm with
21. nd event buffers indication The alarm buffer is indicated by default If you are in the event buffer the unit changes automatically to the alarm buffer after 1 minute without activity If there are no entries in the alarm buffer the display shows the actual date and time gt To switch from alarm to event buffer and vice versa press o and L ON KL gt Scroll the alarms or the events with k l gt Scroll the alarms only with the Green button Display indications With the Yellow button you can switch between three available information blocks The following information is displayed when an alarm or a message arrives First information block Incase of a floor room bed display mode 1 2 HELF Aas FLigiz Bsp BE aei 3 3 3 1 criterion of the alarm or message 2 alarm A or event E followed by its order in the buffer 3 identification of the transmitter location floor room bed numbers Incase of single number display mode 1 2 1 criterion of the alarm or message 2 alarm A or event E followed by its order in the buffer 3 identification of the transmitter location three digits or four signs Second information block date of the event time of the event main unit space or relay Unit A f identification number E EE quality of the received radio signal This information is visible in all display modes F 01U 252 722 V1 2011 12 User Manual Bosch Security Sys
22. nmental conditions Operating temperature O 40 C F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems LA NurseCall Relay Unit len 3 A 4 List of criteria Criterion Number Alarm A or Event E Comment ERROR 00 A Sistem malfunction ea component defective Coded key active N46 es e E _ kno wledgement Sent by NAS zeen m gt m E DOOR E Door open or door closed PERSONNEL C 06 SE Coded key presence N46 mmm a a END PERSONNEL C BE Removed coded key N46 PERSONNEL D Coded key presence N46 PERSONNEL B Coded key presence N46 RADIO NOISE Bad radio transmission noise ACK TRANSM 1 Acknowledgement Ack Transmitter No 1 LOCAL ACK 18 Local Acknowledgement Main Unit or Relay Unit POWER OUTAGE Main Unit or Relay Unit not powered POWER BACK Power back Main Unit or Relay Unit COMPUTER OFF Alarm management PC off COMPUTER ON Alarm management PC on BAT ACK TRANSM Battery at low level One of the Ack Transmitter RELAY ON Relay Unit connected on RS 485 Bus RELAY OFF Relay Unit disconnected from RS 485 Bus NO RELAY Relay Unit off acknowledged Main Unit LOW ACCU Accumulator discharged Main Unit or Relay Unit ACK TRANSM 2 Acknowledgement Ack Transmitter No 2 ACK TRANSM 3 Acknowledgement Ack Transmitter No 3 ACK TRANSM 4 Acknowledgement Ack Transmitter No 4 ACK TRANSM 5 Acknowledgement Ack Transmitter No 5 ACK TRANSM xx Acknowledgement Ack Transmitter No xx ACK
23. ox 6 Configure the display of the 10 identification positions The outcome is visible at the top DH ON ie kb dr a Selecta field with GA and change a value with RS and b Confirm with OK User Manual F 01U 252 722 V1 2011 12 24 en Programming 4 4 5 NurseCall Relay Unit c Choose 0 to 9 characters for the criterion followed by 0 to 9 spaces Default values are 2 characters 1 space 7 Repeat the operation for a the floor 0 to 3 characters and 0 to 9 spaces by default 2 characters and 1 space b the room 0 to 3 characters and 0 to 9 spaces by default 2 characters and 1 space c the bed 0 or 1 character by default 1 character NOTICE Configuration of the display is possible only in display mode FL RO BE floor room bed If the NurseCall system is in display mode NUMBER there is no need of further programming Selection DISPLAY NORSK NOTICE The display mode NUMBER ZZZZ alphanumeric display is not compatible with the Display Norsk Make sure to choose another display mode when connecting a Display Norsk to the Relay Plus Unit See the NurseCall Main Unit user manual for more information gt if you have selected DISPLAY NORSK press ok to confirm 1 Set the rotational display of alarms 2 Select YES or NO with C A and Default value is YES Confirm with ox 3 Configure the display of the 6 identification positions The outcome is visible
24. p Relay Plus Unit only Locating mode and identification number are set at first use To change a value reset the 20 20 Assistance and fire priority 21 O 22 22 5 unit See Section 4 3 2 Resetting all the parameters and buffers page 21 Parameters set by the NurseCall Main Unit The parameters listed below are programmed in the Main Unit and are applied to the Relay Unit See the NurseCall Main Unit user manual Display mode Unit language Date and time Local acknowledgement and the access code Output relay function and mode Locating mode and identification number 1 Disconnect the NurseCall Relay Unit from the RS 485 bus 2 Switch the NurseCall Relay Unit on with the switch located at the bottom of the unit Wait for the following display to appear 3 Enable ON or disable OFF the indication of the transmitter position locating mode on the NurseCall Relay Unit display It must be the same as in the NurseCall Main Unit S d gt Press io disable or D to enable the locating mode 4 The identification number of the NurseCall Relay Unit must now be attributed The identification number is attributed by the NurseCall Main Unit upon connecting the RS 485 bus corresponds to the order of connection It can also be set manually The range for this value is A B C Y Z a b c d e f for a maximum of 32 Relay Units Automatic attribution by the NurseCall Main Uni
25. posed to fire Use only original batteries intended for your NurseCall Relay Unit Do not expose the battery to liquids Do not let the battery s contacts touch another metal This could damage the battery Do not disassemble or modify the battery Do not expose the battery to extreme temperatures and never above 60 C 140 F For maximum battery capacity use the battery at room temperature Keep out of reach of children Use the battery for the intended purpose only Do not put the battery in the mouth Battery electrolytes may be toxic if swallowed CAUTION There is a risk of explosion if battery is replaced by a wrong type The battery should be replaced exclusively by authorized personnel Dispose of used batteries according to instructions and regulations Procedure 1 Disassemble the unit as described in Section 6 5 1 Disassembling the unit page 29 Disconnect the battery cable 1 Carefully remove the backup battery 2 Place the new backup battery 2 Connect the new battery cable 1 F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems NurseCall Relay Unit D 7 1 1 2 1 3 1 4 Bosch Security Systems Disposal en 31 Disposal The NurseCall Relay Unit is marked with a crossed out wastebasket symbol This means that at the end of its lifetime the product should be disposed separately from ordinary household waste in accordance with the
26. s User Manual F 01U 252 722 V1 2011 12 12 en Description 2 2 4 2 2 5 NurseCall Relay Unit RS 485 interface One NurseCall Main Unit and up to 32 NurseCall Relay Units can be connected by a RS 485 bus The bus must be connected to pins 2 and 5 of the RS 485 socket gt For connector wiring see Section A 5 4 RS 485 socket unit rear page 34 NOTICE Keep polarity equal when connecting further units to the RS485 bus NOTICE Maximum RS485 bus length 1200 m Use only one twisted pair cable for the interconnection NOTICE The receiver units located at the two ends of the bus must be terminated with a 100 Ohm resistor See Section 3 2 7 Connecting the RS 485 page 17 for more information about the jumper setting In this configuration you always should connect the NurseCall Main Unit first The NurseCall Relay Units must then be connected to the RS485 bus one by one not at the same time Relay output In the same connector a potential free contact is available It is a low current switching contact The relay potential free switching power max 48 V 0 5 A is activated at a call for help call for assistance or fire alarm This relay can be set as closing or switching contact cycle of 10 seconds on 10 seconds off This feature can be used to drive a signal lamp for example gt For connector wiring see Section A 5 4 RS 485 socket unit rear page 34 gt For relay setting see the user manual of the Nurse
27. t c 5 a Press C or the Red button to erase any previous selection The black box remains 5 6 Connect the NurseCall Relay Unit to the RS 485 bus Press ox or the Green button to enable the automatic attribution The next free identification number is attributed by the Main Unit and is displayed on the Relay Unit at the bottom right F 01U 252 722 V1 2011 12 User Manual Bosch Security Systems NurseCall Relay Unit 4 3 4 3 1 4 3 2 4 3 3 Bosch Security Systems Programming en 21 Manual selection of the NurseCall Main Unit 5 a Scroll with e and KY to set manually the identification number Confirm with ox or the Green button The Relay Unit signalizes that it is not connected to the RS 485 bus bb Connect the NurseCall Relay Unit to the RS 485 bus The identification number is now displayed at the bottom right Special settings After pressing lo three times quickly you can enter special codes Displaying the firmware version 1 Type the code 194155 2 The version of the firmware will be displayed for a few seconds Resetting all the parameters and buffers CAUTION Disconnect the RS 485 bus before performing a reset Reconnect it when you are finished NOTICE The following procedure resets the NurseCall Relay Unit to its original factory settings It erases all the parameters as well as the alarms and events buffers This reset is mandatory if you wish to change the locat
28. tems NurseCall Relay Unit 5 2 3 5 2 4 Bosch Security Systems Operation en 27 Third information block 8 position of the last passed beacon visible in all display modes If no beacon is registered or if the alarm is sent outside of the range of a beacon the POS 000 will be displayed In the alarm buffer the total number of entries is indicated on top at the right You can immediately see how many alarms are active In this example there are a total of three alarms in the alarm buffer In the event buffer the position of the event in the buffer is indicated Here EO1 corresponds to the latest entry in the event buffer Unit displaying the current date and time The green button does not work Problem you have tried unsuccessfully to acknowledge an alarm with the Green button Cause the local acknowledgement is disabled Solution activate the local acknowledgement function See the NurseCall Main Unit user manual Disconnecting a Relay Unit If a Relay Unit stops communicating with the Main Unit an alarm Relay Off is generated on the Main Unit This alarm can only be acknowledged on the Main Unit by pressing the Green button followed by the code 45 Thereafter an event No Relay is generated As soon as the Relay Unit communicates again with the Main Unit the Event Relay On is generated This operation is independent of the local acknowledgement setting User Manual F 01U 252 722 V1 2011 12
29. y disconnected Green flashing Help assistance or fire Red blinking 2 1 4 Relay Unit rear view 1 RS 485 connector See Section A 5 4 RS 485 socket unit rear page 34 for wiring 2 Antenna connector 2 1 5 Relay Plus Unit rear view 1 2 3 000o oo0oo0o0 1 RS 232 connector used for the printer display interface of the Relay Plus Unit See Section A 5 3 RS 232 socket Relay Plus Unit rear page 34 for wiring 2 RS 485 connector See Section A 5 4 RS 485 socket unit rear page 34 for wiring 3 Antenna connector Bosch Security Systems User Manual F 01U 252 722 V1 2011 12 10 en Description NurseCall Relay Unit 2 2 Detailed description 2 2 1 Loudspeaker When one of the following alarms or messages is received by the NurseCall Relay Unit the internal loudspeaker is activated until acknowledgement Loudspeaker Power supply disconnected Dual tone beep every minute Call for help reserve call technical call 4 second interval one tone Error message 15 second interval one tone Disconnection of a relay unit from RS485 bus 1 minute interval one tone Call for assistance fire alarm Continuously dual tone beep Local acknowledgement Short beep 2 2 2 Display The NurseCall Relay Unit is equipped with a 2 x 20 characters display that guides the operator during the programming During normal operation alarms

Download Pdf Manuals

image

Related Search

Related Contents

ZVP-VDA-321-4  U2—E:t l —muUt:<“» c.—  manual del propietario  Istruzioni d`Uso - Audio-luci    AIDE ENTREPRISE SIS-ePP® Plateforme de dématérialisation des  Piano di Sicurezza e coordinamento  Samsung 32" Full HD Flat TV J5000 Series 5 Наръчник за потребителя  Philips F-Type SWV3536/10 User's Manual    