Home

Bosch Appliances D1265 Home Security System User Manual

image

Contents

1. D1265 Owner s Manual Contents Change Time Date CMD 4 5 37 Door Control CMD 4 6 39 Descrip EE 39 Usine Door Controlere erra eera enie E 39 Access HEV E 4 Change Display CMD 4 9 42 Show Continuous Ime Date 42 Extend Closing CMD 5 1 42 Cho Sked CMD ES ED kass 44 Re EE 44 Usimo RE 44 Delete User CMD 5 3 46 Change Relay CMD 5 4 47 Change Passcode CMD 5 8 47 Ps ernia 47 Using Change Passco descrita buin 47 Add Change User CMD 5 6 48 Default Text CMD 5 7 55 Fire Test CMD 5 8 55 Display Rev CMD 5 9 57 Service Menu 9 9 Enter 57 Usine ViewLoS aia 58 Usine Print Lo EE 58 Using Display Revisioni uit 58 Using Service Walk Testi cds 59 Usne Delano ia 59 Keypad Setup Ment usas iatale 59 Part IV Multi Area USe cccssccsccssssscsscssssscccsssesees 60 Working with Multiple Areas from a Single Keypad 60 NIM ALA Dalila 60 View Nee EE 61 Move To Area CMD 5 0 62 Turing On the Sy temida 62 Turning on Selected Areas asak 62 Turning on Multiple Areas with a Passcode 63 Faulted Points in Other Areas ii 63 Turn On the Entire System Without Delays 64 Turning on All or Selected Areas 64 Turning OH the System inscrit 65 Turning Off Multiple Areas with a Passcode 65 Turning Off Multiple
2. View Faulted or Bypassed Points To properly arm your system all the exterior points doors and windows and interior points motion sensors inside doors and so on in the system must be in the normal not faulted condition Viewing the faulted points helps you find faulted points such as doors or windows that are left open and correct them sO proper arming is possible Your keypad offers a way of displaying faulted and bypassed point information To Scroll Faulted or Bypassed Points 1 Ensure your keypad shows idle text AREA 1 WAREHOUSE NOT READY TO ARM View Points i Help Menu o8 8 00 Ea 09600045 2 Press the View Points button to show the first faulted point 3 Press the Next button or the Previous button repeatedly to show the faulted and bypassed point information 4 If faulted or bypassed points in other areas exist then the display indicates the Area number and the number of faulted bypassed points before returning to idle text 5 Ifthere are no faulted or bypassed points in other areas the display returns to idle text 10 Warning Displays and Tones Your keypad emits one of several distinct tones and displays custom text to alert you to system events Additional bells or sirens might also be connected to your system Bells or sirens mounted on the exterior of your premises alert neighbors to emergencies and provide an audible guide for police and fire fighters Keypad Quiets for Butto
3. E JE E 28 ChangeRelays CMbs4 P JE E 29 Remote Program ___ CMb43 P E JE E JE 30 MoveToArea CMbso P_ JE JE Ol EEE toa 33 Service Wat TPT 34 Default ext J CMBS7 JP E 1 J EES Pele E 4 35 ChangeSkeds CMD52 P E 36 Invisible Walk Test___ ______ P_ JE lt Keypad Function Authority Level Options Blank Disabled E Enabled D9412GV3 D7412GV3 D9412GV2 D7412GV2 only Authority Level 15 can not be edited User Interface Authority Levels EEE E Functions Command ere 1 2 Ja 4 5 o 7 e 5 10 1 13 Custom Functions 128 Custom Function 128 PLE 129 Custom Function 129 PEE 180 Custom Function 130 PLE 181 Custom Function 131 PEE 182 Custom Function 132 Ip JE 183 Custom Function 133 IP JE 184 Custom Function 134 IP JE 135 Custom Function 135 PEE 186 Custom Function 136 PLE 187 Custom Function 137 JP JE oT T T 138 Custom Function 138 JP Je 189 Custom Function 189 P E 0 140 CustomFunction140 a a Aaa a Pp Je 7 0 141 CustomFunctiont44_____ P_ JE 0 142 Custom Function 142 P E 143 CustomFunction143 TP TE tt e Access Level
4. A A Use the CMD button in combination with one or two numeric buttons to perform a function ez The ENTER button is used to complete the entry of your passcode at the keypad E N ali E R Whenever a function requires that you enter your passcode at the keypad first press the digits of the code and then press the ENTER button Your system will not recognize your passcode until you press ENTER E E When the Exit button appears in the keypad display pressing it brings you one level up in the function or exits you from the function you are in These functions might be shown on either side of the display previously shown item Previous When viewing a list pressing the Previous button takes you back to the Previous Next Press the Next button to pass over the present item s in a menu or function Points What is a Point A point is a detection device or group of devices connected to your security system Points display individually at the keypad with custom text The text can describe a single door motion sensor smoke detector or an area such as UPSTAIRS or GARAGE There are two basic types of points controlled and 24 hour Controlled Points Controlled points respond to alarm conditions depending upon whether the system is turned on armed or turned off disarmed Controlled points are programmed to respond instantly to alarm conditions or to provide a delay for you to reach the keypad and disarm the syste
5. Inc 9 10 FO1U169130 02 D1265 Owner s Manual Appendix User Passcode Worksheet User 227 to 249 101 249 D9412GV3 D9412GV2 only User Area Authority Passcode Group 3 4 5 6 User Name USER 227 USER 228 USER 229 USER 230 USER 231 USER 232 USER 233 USER 234 USER 235 USER 236 USER 237 USER 238 USER 239 USER 240 USER 241 USER 242 USER 243 USER 244 USER 245 USER 246 USER 247 USER 248 USER 249 Bosch Security Systems Inc 9 10 FO1U169130 02 81 D1265 Owner s Manual Appendix User Token Worksheet User 227 to 249 101 249 D9412GV3 D9412GV2 only User Master ID 0 CT ST TI SES um TI ZE 82 Sub User 1 Site Sub User 2 Bosch Security Systems Inc 9 10 FO1U169130 02 Sub User 3 Card Data D1265 Owner s Manual Appendix User Passcode Worksheet Blank User Area Authority Passcode Group elle User Name Bosch Security Systems Inc 9 10 FO1U169130 02 83 D1265 Owner s Manual Appendix User Token Worksheet Blank Use Master ID 0 Sub User 1 Sub User 2 Sub User 3 Security System Limitations e Smoke detectors cannot detect smoke in chimneys walls or roofs or smoke blocked by a closed door They might not detect smoke or fire on a level of the building different from the one on which they are located Smoke detectors might not be able to warn in time about fires started by explosions improper storag
6. before it returns to idle text If you enter this function and the detector or sensor resets momentarily but then returns to a faulted condition the conditions causing the activation might still be present or the detector might be faulty Check to be certain that there is no smoke fire or other danger present If you can t reset the detector or sensor contact your security company 25 D1265 Owner s Manual Part Il System Commands Watch Mode CMD 6 Description With your security system disarmed you can use watch mode to monitor some points Each time some points are faulted door or window is opened the keypad chimes once and shows the point text for 60 sec No alarms are generated by this mode except 24 hour alarms fire panic and so on Use this function in residential systems to monitor entries or exits in your home In commercial systems it can serve as a door chime to alert you when a customer or delivery person enters your business Contact your security company to find out which points are watch points and whether or not your system automatically turns the Watch Mode on whenever you disarm Using Watch Mode Description With your security system disarmed you can use watch mode to monitor some points Each time some points are faulted door or window is opened the keypad chimes once and shows the point text for 60 sec No alarms are generated by this mode except 24 hour alarms fire
7. keypads or detectors yourself How to Clean the Keypad If your keypad gets dirty apply a household glass cleaner to a clean cloth or paper towel and wipe the surface Do not spray any liquid directly onto the keypad It could run inside the case and damage electrical circuits Your Alarm Company Name Call This Number Before Testing 90 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Notes Notes Bosch Security Systems Inc 9 10 FO1U169130 02 91 S Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 USA www boschsecurity com Bosch Security Systems Inc 2010 BOSCH
8. opened doors or windows that are force armed are not included in the system The remaining points arm normally Force armed points either return to normal operation after you turn your system off or return to normal when the door or window is closed Your system might not offer force arming or it might be restricted to specific points Contact your security company for more information Use your passcode or an arming function to start the arming process 1 Ensure the display shows Check Area 2 One of the messages below might display in place of Check Area P3 DELAY cannot be bypassed ES KID 000803 This display indicates the system is programmed not to arm with particular points faulted doors or windows open There are too many bypassed points o 8 8 a GB This display indicates that the system s number of allowable bypassed points has been reached Your system s maximum number of bypassed and or force armed points is set by your security company Check with them to learn this number 17 D1265 Owner s Manual Part Il System Commands There are too many faulted points gaga a EKB 096090045 This display indicates that more than the number of allowable points are faulted Bypassed points are counted as faulted Your system s maximum number of bypassed and or force armed points is set by your security company Check with them to learn this number 3 The display show
9. 1 The Time Date Display button is used to show 2 3 4 how the time and date entered appears Ente de ML 9 The new time and or date is shown for 20 sec AER before the display returns to idle text AREA 1 WAREHOUSE EXIT ENTE Two 07 28 10 9 58AM _Help Menu NR SS o qu a Y O DOG Press the Exit button to return to idle text x A No a Press the ENTER button 6 The display changes to show AM or PM buttons Enter new time PAS REA AM PM RD Exit ire a eege Wee AABE CMD Press the AM button to select AM Press the PM button to select PM 7 The display shows Enter new date Enter new date deg Time Date Display 844 GG KB O B O O O CD Refer to Step 9 for use of the Time Date Display button If you input the wrong date press the Exit button to clear the date Enter the new date using a MM DD YY format Example If the desired time is July 28 2010 press0 7 2 8 1 0 Enter new date MMA RA RA EX1T Enter CMD ae 00 06 38 Bosch Security Systems Inc 9 10 FO1U169130 02 Door Control CMD 4 6 Description There are three functions with the door control function e Cycle Door momentarily unlocks a door to allow a person into an area e Unlock Door unlocks a door to allow free access e Secure Door locks a door and prohibits access regardless of a user s authority level Using Door Control
10. 2 1 Once you start entering digits the Print all events button is replaced with the ENTER button Enter start date mm dd yy Print all events EX1T o8 8 a 8 Ea G A O O O aB Press the ENTER button If the date entered is valid the events for that date is sent to a connected printer and the display shows Printing events for 3 sec before returning to idle text Using Display Revision l Press the Display Revision button 2 The display changes to show the revision 3 number BOSCH D7412GV2 Revision 7 08 5 8 8 GG cs a O O ED 7 The display returns to idle text after 5 sec Bosch Security Systems Inc 9 10 F01U169130 02 Using Service Walk Test 1 The Service Walk Test function is only available in the Service Menu for D9412GV3 D9412GV2 control panels If the control panel model is D7212GV3 D7212GV2 you must enable the Service Walk Test on the Function list for the keypad through the control panel s programming When the display shows points remain to be tested you can begin is the number of points If you know the point number you can enter it by pressing its number button and then the ENTER button The display changes to show the point that was entered If the point is invalid the message Invalid Point or This is not a valid walk point appears Test each point by first opening and then closing the door or window
11. a ICH AAA tes Il bel iI di RE A KANN tes Il E NG 0 ELA Edo LL tes 09892 Il sel i A vo Il KSE Sooo Il ELA Il y Sooo E eli ci Cui I I SS IA Lodo A e Ei E si Li Ao C A ESCH O do sl Loo Il sG Li E EA ll i aaa oo Sra kE los Il Ci IO 0 E Vr ci Ci iii 2 II e il 5 A LL Sri WS EA 78 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Appendix User Passcode Worksheet User 190 to 226 101 249 D9412GV3 D9412GV2 only User User Area Authority HEH Passcode Group 1 2 3 4 5 6 7 8 Bosch Security Systems Inc 9 10 FO1U169130 02 USER 208 USER 209 USER 210 USER 211 USER 212 D1265 Owner s Manual Appendix User Token Worksheet User 190 to 226 D9412GV3 D741 2GV3 D941 2GV2 D7412GV2 Only 101 249 D9412GV3 D9412GV2 only User Master ID 0 Sub User 1 Sub User 2 Sub User 3 ao Tt TT pin OO ONNO IO OO dl ILL ag A A OO E Le A EE A ag poo SO PO O E as Le ILL ag o LI ll ml LI LI ll pio WE SG PO GN ml E ol DG EC WE WE HO 2 a pop OOO 208 ILL ml poo ILL EU ILL mi ILL ml MR WE SO i 208 poo ILL a ILL zio OOO ld ci 0 I sel ILL E ILL aaj ILL asd poo ILL asf JI LI ll Ed LI ll eli ci LI ll mo LI ll p20 LI ll ES RE ci LI ll Sal i Ool Mul sl A LI ll pom LI ll pos LI ll 22 o 0101 1 0 80 Bosch Security Systems
12. addition to turning on without delay all authorized areas that are currently off Turning on All or Selected Areas Areas covered in the scope of the keypad can be armed individually by accessing the Master Arm function through the menu 1 Press the Menu button to enter the function list 2 Press the Next button repeatedly until you reach the Master Arm Instant button and then press it Master Arm Instant 3 You might be prompted for your passcode It appears on the display as asterisks Enter passcode Entering E exit Na 4 The display changes and shows Master Arm All with the following options e Previous button scrolls to the last area that can be armed based on passcode and authority level e Next button scrolls to the first area that can be armed based on passcode and authority level e Arm button arms all areas based on passcode and authority level e Exit button returns the display to idle text Master Arm All Next Arm a O A G O O aD 5 Ifthe Next button is pressed the first area that can be armed based on passcode entered and user authority level is shown AREA 1 WAREHOUSE is used an example of the first area that can be armed 64 Pressing the Arm button causes AREA 1 WAREHOUSE is now arming to display for 3 sec before the prompt to arm the next available area is shown Arm Instant All Next gt E ayana BE ENTER To insta
13. least 5 sec The adjustable functions that are available in this menu are e Set the keypad s SDI Bus address e Adjust the keypad volume and display brightness e Turn the button click tone on or off e Set the screen on time Use the up and down buttons for each function to change the setting for the options e Keypad Address SDI bus address e Keypad Volume Applies to low priority tones only e Button Click Key press acknowledgement e Brightness e Screen On Time Time in minutes before power saving mode activates Press Save to save your changes when finished The display returns to idle text Press Back to exit the menu Button Click purton us 99 D1265 Owner s Manual Part IV Multi Area Use Part IV Multi Area Use Working with Multiple Areas from a Single Keypad Each of the functions described in the preceding section on Advanced Commands is presented as though your system includes only one area If your system includes more than one area it can be set up in one of two ways by the installing company e Each keypad only has access to the local area to which it is assigned or e Each keypad might access either some or all areas beyond the one to which it is assigned This factor is referred to hereafter as keypad scope If your keypad allows access to areas other than the local area that is to say has scope in other areas then the keypad limits your access to those areas with
14. only 81 User Token Worksheet User 227 to 249 101 249 D9412GV3 D9412GV2 only ie 82 User Passcode Worksheet Blank 83 User Token Worksheet Blank 84 Security System Lmtatons eee eee eee eens 84 Fire Safety and Evacuation 85 SEL RRE OT 86 System Trouble DisplayS ss 87 Secnny Ee 89 Maintenance and Service 90 How to Clean the Keypad in 90 Your Alarm EE 90 Bosch Security Systems Inc 9 10 FO1U169130 02 Figures Figure 1 D1265 Touch Screen Numerical 6 Figure 2 Smoke Detector Locations Plan View 85 Figure 3 Smoke Detector Locations Elevation Keelt eiis ee 85 guggenb geg 85 Tables Table 1 D1265 Keypad Buttons 7 Table 2 Keypad Commands raiu una 15 Tables DO Or SEALS ariete 39 Table 4 Sked ale ari vait laia R 45 Table 5 Screen Area Definitions 61 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Figures D1265 Owner s Manual Introduction Introduction Your security system helps to secure life property and investments against fire theft and bodily harm The D1265 Touchscreen Keypad is an SDI compatible device that works with GV2 GV3 Series Control Panels Each keypad has an illuminated touchscreen to display system messages and graphics buttons for data or command entry and a sounder that emits eight warning tones Your Keyp
15. that the system is not currently performing a function entered by a user There are three idle states the system might be in e Turned on Armed e Turned off Disarmed with no points faulted doors or windows open in the area e Turned off with faulted points doors or windows open in the area This manual uses the default idle state shows for examples of these idle states Your security company might have programmed custom text for the idle shows in your system The custom text and the default text for the three system idle displays follow ieee Area Name Text Appears on the top line of the display and is customizable using Remote Programming Software RPS Throughout this manual all examples of AREA NAME TEXT use AREA 1 WAREHOUSE The actual name of Area 1 differs depending on the specifics of your system Area Is On Text P240 Al AREA IS ON Help CAM a 8 E du o o DEE Area Off Text P240 i ci Indicates the area is turned off Al AREA IS OFF disarmed 24 hour points remain armed Help Menu E Tee Ts KB o ue E El GO Gi Area Not Ready Text P240 Indicates that the area is turned off NOT READY TO ARM but not ready to arm View Points Help Menu O a E U El ED o e E El QU GZ The Silence button only appears if the trouble tone is sounding Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Security System Basics
16. the level the display prompts you again to enter an This function is used to manually enable disable access Aadi bevels modi authority levels assigned to users It can also be used to temporarily disable a user s access level instead of Access Control deleting and then re adding the user Level OQ Ihave this feature Enter Level ENT A Enter 00000 duda Y FENTER 10 Press the Exit button when you are finished a Ido not have this feature Ensure your keypad shows idle disarmed text Press the Menu button to enter the function list Press Next button repeatedly until you reach the Change Level button Cnange Level Press the button 4 The display prompts you to enter your passcode Enter your passcode and press the ENTER button 5 A prompt appears asking for entry of the Authority Level to be modified Access Control Leve Enter Level AA ES GUGOAGEE 6 Enter the level number 1 14 and press the ENTER button 7 If the level entered is currently enabled the keypad asks if you want to disable this level Level 1 is Enabled MTU sab EMV Be 00000 8 If the level entered is currently disabled the keypad asks if you want to enable this level Level 14 as Disabled Enable Leve GES 00000G5 Level 1 is used here as an example Bosch Security Systems Inc 9 10 FO1U169130 02 41 D1265 Owner s Manual Part Ill Advanced Commands Ch
17. the entry delay to start if the person exits through a point designated Entry Exit door Exiting through any other point could cause an immediate alarm Moving into the interior of the protected area causes an alarm on an interior device If an alarm occurs enter your personal passcode to disarm the system Your cleaning service a serviceman or others might also use this function to turn on your system when they leave Using Master Arm Using the CMD 1 command only arms the area currently displayed on the top line of the keypad display For example if the keypad is assigned to AREA 1 WAREHOUSE only AREA 1 WAREHOUSE arms when CMD 1 is pressed 1 Ensure your keypad shows idle text AREA 1 WAREHOUSE Al AREA IS OFF SCH GEI 0000045 Press the CMD button The display shows System Command System Command 9000005 O 4 Press the 1 button Bosch Security Systems Inc 9 10 FO1U169130 02 P D1265 Owner s Manual Part Il System Commands If your system is programmed to require a passcode when performing a CMD 1 the display prompts you to enter your passcode The passcode is shown as asterisks Enter passcode Entering DUE op e ae E O Ga If the passcode has valid authority for this command the display shows Exit Now exit delay time remaining seconds remaining Exit Now 16 seconds remaining eeedeca a a a 90 cz AREA 1 WAREHOUSE Al AREA I
18. the new passcode again As soon as a number is pressed Entering appears on the third line next to the asterisks Enter new passcode again AAN E HD O o O O O CE The passcode is shown as asterisks when entered and advance from the right side of the display to the left until all six passcode digits are entered If the passcode matches the previously entered passcode the display changes to Passcode changed Passcode changed 00500052 If the passcode does not match the keypad emits an error tone and displays Passcode not changed The display automatically returns to idle text after 3 sec Add Change User CMD 5 6 Use this function to add or change a user to your system without assistance from your security company You need to know which user numbers are available the authority level you want to assign to the new passcode and the areas in which it is valid before you add it The user numbers identify users in reports transmitted from your system Additionally you are able to change the following the authority level which determines what system functions the passcode can access the area number which identifies which parts of your security system the user has access to the name of the user door access card or token they use for access control the door access card or token associated with the Master or Sub User Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owne
19. then press the ENTER button Change Relay Enter relay number 1 Bosch Security Systems Inc 9 10 FO1U169130 02 5 Ifthe relay is valid and turned off the display changes to Change Relay Relay 123 is currently off 123 is used as an example Press the Turn on button to turn on the relay 6 Ifthe relay is valid and turned on the display changes to Change Relay Relay 123 is currently on 123 is used as an example Press the Turn off button to turn off the relay 7 The display returns to the Change Relay Enter relay number Press the Exit button to return to idle text The on board relays use the following numbers Relay A 250 Relay B 251 Relay C 252 Change Passcode CMD 5 5 Description Use this function to change your personal passcode without assistance from the security company Before you begin e Choose a new passcode three to six digits long If you choose a passcode with the same digit in consecutive order for example 33 in 334697 take care when entering it e To avoid conflicting with other passcodes and duress codes your system will not let you change passcodes to an existing passcode or to within plus or minus 2 of an existing passcode For example if 1234 were an existing code your system would not let you change your code to 1232 1233 1234 1235 or 1236 Using Change Passcode 1 Ensure your keypad shows idle disarmed text 2 Press the CMD
20. to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Add Change User button press It Change User Bosch Security Systems Inc 9 10 FO1U169130 02 The display changes to show Add Change User Enter user Add Change User Enter user EX1t Enter 8448 GG cs Enter the user number and press the ENTER button The display changes to show the user number entered and the user s name if any User 3 is used as an example Press the Continue button to proceed on to changing the user s information If there is no name for the user the default user name text appears in the second line User 3 is used as an example Press the Continue button to change the user s information Continue sued E E 0000465 The display changes to Add Change Menu The display varies depending on the type of control panel that was installed in your system Q Door access control in the control panel D9412GV2 D9412GV3 D7412GV2 D7412GV2 O My system does not have door access control in the control panel D7212GV3 D7212GV2 49 D1265 Owner s Manual Part Ill Advanced Commands If your system has a door access control available in the control panel this menu allows the following User items to be changed e Passcode Press the Passcode button to change the user s passcode e Level Press the Level button to chan
21. 1 Ensure your keypad shows idle disarmed text AREA 1 WAREHOUSE LN A IS h Pa p Prev1ous Next Ex1t 22823 a gy 0000465 2 Press the CMD button The display shows System Command System Command 5 8 8 0 8 Ea a 06H 3 Press the 4 button and the 6 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Door Control Menu button press it Door Control Menu Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Ill Advanced Commands 4 The display changes and shows all authorized choices of Cycle Door Unlock Door and Secure Door Gelee hits sia cycle Door unlock Door es EXE 000005 Press the desired button Cycle Door 1 If you wish to momentarily unlock an access door to allow a person into an area press the Cycle Door button 2 The display reads Cycle Door 1 2345678 if all door are at a normal state and are available If a door is not at a normal state the number of the door would be replaced with a symbol indicated in Table 3 Secure Door 1 MS Ss 608 728 select Door and 0 UCS gogo 00000 If a door is not at a normal state the number of the door would be replaced with a symbol indicated in Table 3 Table 3 Door Status Symbol Meaning 09 Do
22. 28 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Il System Commands Using Command 9 1 Ensure the display shows disarmed idle text 2 Press the CMD button The display shows System Command 3 Press the 9 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the User Command 9 button press It User Command 9 4 Your Command 9 special alert has been programmed to Q notify your alarm company ring a bell on your premises O display at your keypad Description Bosch Security Systems Inc 9 10 FO1U169130 02 29 D1265 Owner s Manual Part Ill Advanced Commands Part III Advanced Commands Use this section of the manual to perform advanced system functions like add and delete user passcodes reassign authority levels to user passcodes and operate or change programmed scheduled events Skeds from the keypads As you make changes to the system update the information contained in the tables in this guide to provide an accurate account of the programmed information Advanced Commands COMMAND COMMAND a Change Sked A Unbypass a Point Delete Passcode E ER Change Rela a a au O MN Change Passcode TA o Ma Add Passcode oe ao wee j E Ea Default Text DO Access Level Change E Display Rev Change Dis
23. 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Display Revision button press It 4 The display changes to BOSCH D7412GV2 D7412GV2 is used as an example other control panels could be D9412GV3 D9412GV2 D7412GV3 D7212GV3 D7212GV2 BOSCH D7412GV2 Revision 7 08 08008 E ENTER 7 5 The display returns to idle text after 5 sec Bosch Security Systems Inc 9 10 FO1U169130 02 Service Menu 9 9 Enter The service menu is used to access the following commands o o A View Log Use this function to review events in your system at your keypad Reviewing past events might help you identify problems Viewing events will not require any additional equipment since the information is shown at your keypad Events are stored in the control panel s memory in order of occurrence and tagged with the date and time Print Log The Print Log function lets you print the events stored in your security system s log You can choose to print the entire log or set a start date and print the events recorded from that date up to today Your system must include a parallel printer interface and a printer to perform this function Display Rev COMMAND 5 9 The command retrieves the control panel s software version and display it Service Walk D9412 D9112 only The command allows all the points on the system to b
24. 60 sec that the point has been tested This verifies that each detection device is working properly Using Walk Test 1 Ensure the display shows disarmed idle text 2 Press the CMD button The display shows System Command System Command 3 Press the 4 button and then the 4 button e 24 If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Walk Test button press it The burglary bell sounds for 2 sec When the display shows points remain to be tested is the number of points you can begin 6 points remain to be tested View untested pts End test 848 09 cs Test each point by first opening and then closing the door or window or activating the other detection device types Check the display after testing each point For interior points walking past the device once is sufficient If any point will not test correctly contact your security company for service During the Walk Test you might want to refer to the points that remain untested by pressing the View untested pts button View untested pts The display shows pts untested 6 pts untested Next Pt PLEVEL TLITI 00108003 Press the Next Pt or Prev Pt buttons to refer to information about specific points that have not yet been tested Bosch Security Syst
25. An important piece of information included in the passcode worksheet is the listing of areas to which the user has access along with the authority level assignment for each of those areas User Interface Authority E E E Functions Command Jere 1 2 1 Disarm CT P JE E 2 MasterArmDelay __ CMD1 __ P_ E JE 3 MasterArminstant _ CMD11 JE IE 4 Perimeter Instant __ CMD2 __ P__ E E 5 Perimeter Delay __ CMD3 Ip E JE 6 Watch Mode __ CMbe E E E 7 PerimeterPat CMD8 Ip JE JE 8 _ View Area Status JP JE JE 9 ViewMemory CMD40 E E JE 10 ViewPtStaus E JE E E 12 FireTest______ CMD58 Ip E E 113 SendReport CMD41 42 P_ 14 DoorControl CMD46_ P_ E E eCycleDoor JE e E eUnlockDoorr E E JE SecureDoor JE e 37 Access Control Level 17 ChangePasscode CMD55 Ip E 18 AddUser______ CMD5s6_ POE 19 Deise CMD53 Ip E Bosch Security Systems Inc 9 10 FO1U169130 02 Levels 3 le 5 e Jz lo jo jr 11 12 13 ra 67 D1265 Owner s Manual Appendix 20 ExtendClose CMosi P 21 Vewlog JE Je to o 22 Printlog____ ___ P Je 23 UserCommand7____ CMD7__ P 24 UserCommand9 CMDe_ P_ 25 BypassaPoint_____ CMDO_ P_ JE E E E 26 UnbypassaPoint CMDoo P_ E JE E JE
26. Areas with Disarm Al 65 Turning Off Selected Areas iii 66 Appendix A A aaea aa adaa 67 Supplementary Information for Adding Passcodes 67 User Authority Levels inseneri o i 67 Passcode Worksheet aidata nE 67 Userini ilice aaa 67 User Mier AE aiamaa 68 4 User Passcode Worksheet User 000 to 038 69 User Token Worksheet User 000 to 038 D9412GV3 D7412GV3 D9412GV2 D7412GV2 Only See 70 User Passcode Worksheet User 039 to 075 71 User Token Worksheet User 039 to 075 D9412GV3 D7412GV3 D9412GV2 D7412GV2 Only EE 72 User Passcode Worksheet User 076 to 114 101 249 D9412GV3 D9412GV2 only iii 73 User Token Worksheet User 076 to 114 D9412GV3 D7412GV3 D9412GV2 D7412GV2 Only 101 249 D9412GV3 D9412GV2 only 74 User Passcode Worksheet User 115 to 150 101 249 D9412GV3 D9412GV2 only 75 User Token Worksheet User 115 to 150 101 249 D9412GV3 D9412GV2 only 76 User Passcode Worksheet User 151 to 189 101 249 D9412GV3 D9412GV2 only ine 77 User Token Worksheet User 151 to 189 101 249 D9412GV3 D9412GV2 only 78 User Passcode Worksheet User 190 to 226 101 249 D9412GV3 D9412GV2 only 79 User Token Worksheet User 190 to 226 D9412GV3 D7412GV3 D9412GV2 D7412GV2 Only 101 249 D9412GV3 D9412GV2 only 80 User Passcode Worksheet User 227 to 249 101 249 D9412GV3 D9412GV2
27. Change Skeds button press it 8 4 The number of the first Sked programmed into your system is shown plus either its time or an indication that it is disabled 9 Press the Next button to scroll through the list of Sked numbers to find the one you wish to change Your alarm system might be programmed with up to 40 Skeds If the Sked number being shown is not programmed the keypad shows Skd11 No program 44 When an X appears in the Sked display it is an indication that Except on Holidays is enabled Specific holidays are programmed by your security company When an appears in the Sked display it is an indication that the Sked has or happens today If the Sked is currently enabled the sked is shown with Disable this sked on the second line Press the adjacent button The display changes to show that the sked is disabled If the Sked is currently disabled the display reads Skd 1 is disabled Press the Enable this sked button The display shows two buttons Only on holiday Pressing this button enables the sked only on holidays and change the first line of the display to Skd 1 X 08 00AM without the X Except on holiday Pressing this button disables the sked on holidays and change the first line of the display to Skd 1 08 00am with the X Consult your security company and determine which holidays have been programmed in your system The display changes to allow a new time to be entered Enter
28. D1265 AREA 1 WAREHOUSI READY TO ARM Help i iI ER a E 1 lt 37302068 0 AG e d de A 4 KL L A de ai aa KS A Po Owner s Manual EN Touchscreen Keypad BOSCH D1265 Owner s Manual Contents This system includes a telephone line seizure feature The system might be programmed to communicate with a central monitoring station to report system events You cannot use your phone while the system is communicating with the central monitoring station In the unlikely event that the central station is not able to receive the report your phone might be unavailable for up to 20 minutes while the control panel makes additional communication attempts Some commands listed below might not be available Contact your security company for more information 2 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Contents Contents Eet ge ele e A ital 6 our Key 0721 E 6 Part I Security System Basics eereonoonoonooonsonooonee 7 ee e ee tee ebe Eeer 7 Command ENTER buttons 7 A a E E NE 7 Whatisa ee 7 Controlled POH gia apa aastal DN 7 24 TAU FO as 7 Your Custom ERT 9 View Faulted or Bypassed Points n 10 To Scroll Faulted or Bypassed Points 10 Warning Displays and Tones ii 10 Keypad Quiets for Button presses 10 tee a E 10 WE o EE 11 Sileficime EE 11 Duro 1415 Ars sec nendest A
29. Disarm Exit A 00000 Press the Disarm button to disarm all armed areas Press the Next button to go to the first armed area refer to Turning Off Selected Areas on page 66 Press the Previous button to go to the last armed area Press the Exit button to return to idle text If the Disarm button is pressed to disarm all areas the display changes to show Disarm 12345678 All user authorized areas are now disarmed indicating that all areas are being turned off Keypad scope and or your authority level limit the actual number of areas you might turn off Bact tape l Aili s eg 0000053 For example if you have authority to disarm all 8 areas but the scope of the keypad you re using is limited to areas 1 2 and 5 then you only can turn off areas 1 2 and 5 65 D1265 Owner s Manual Part IV Multi Area Use Turning Off Selected Areas If your passcode has the proper authority level this function allows you to turn off areas other than the one you are in 1 The display initially shows that the system is armed Press the Menu button to enter the function list Press the Next button repeatedly until you reach the Disarm Menu button and then press it 4 If entering through a door which is part of an area that is armed the display changes to show 5 Enter your passcode and press ENTER The passcode is shown as asterisks when entered and advance from the right side of the display to the
30. E tt tt ENTER Service Zonex Bus 1 or 2 Shows when a problem has occurred with the control panel s Point Bus Wiring Call your security company AREA 1 WAREHOUSE Service Zonex Bus 1 Silence Help Menu 00000 o e E El QU Cu Fire Point Bypass This display indicates that fire points have been bypassed AREA 1 WAREHOUSE Fire Point Bypassed silence O Y E Y KA 88 24 Hour Point Bypass This display indicates that 24 hour points have been bypassed AREA 1 WAREHOUSE 24hr Point Bypassed silence rT Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Appendix Security System Glossary Area Arm Authority Level Bypass Central Station Closing Report Function List Entry Delay Bosch Security Systems Inc 9 10 FO1U169130 02 A group of detection devices connected to your security system To turn on your controlled points burglar detection devices When an area is armed and a controlled point trips an alarm occurs or entry delay begins When an area is disarmed faulting controlled points will not generate alarms Your security company or security representative assigns an authority level to your passcode The authority level determines what keypad functions you can execute Selectively remove points from the security system You might bypass a point in order to arm the perimeter with a window open A facility where trained
31. ER button to disarm and AREA AREA TEXT is in entry delay Enter Passcode and i eet ea Ea St ence e 000007 AREA 1 WAREHOUSE 1s in entry delay FRONT DOOR osito Y KU EA ER EU E ET a e a a nt ENTER You must turn off the system before entry delay time expires to avoid creating an alarm event Exit Now Arming your system starts exit delay time The keypad emits a repeating beep tone and shows Exit Now 86 Exit Now 16 seconds remaining 0 0 600 GE No Authority The system will not recognize the EE entered 0 ea o o fo E Perimeter On Delayed Indicates that the perimeter is armed turned on with entry exit delay time and shows Perimeter On Delayed Refer to Perimeter Delay CMD 3 on page 22 AREA 1 WAREHOUSE Perimeter On Delayed gegen BS E O 0 O O O C Perimeter Instant Menu Indicates that the perimeter is armed turned on without entry exit delay time and shows Perimeter On Instant Refer to Turn On the Perimeter With No Delays on page 21 AREA 1 WAREHOUSE Perimeter On Instant cea o O Se Area must be disarmed first Indicates that the function requested can only be performed when the area is disarmed Disarm the area to perform the function Area must be disarmed first GES Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Appendix System Trouble Displays If you refer to any of the sy
32. ES 5 E gt Ei ia D E LO d N gt mm A User Token Worksheet User 000 to 038 D9412GV3 D7412GV3 D9412GV2 D7412GV2 Only Gang Master ID 0 Sub User 1 Sub User 2 Sub User 3 Not Available Site Card Data Site Card Data Site CardData Site CardData Bosch Security Systems Inc 9 10 FO1U169130 02 70 D1265 Owner s Manual Appendix User Passcode Worksheet User 039 to 075 User User Area Authority Passcode Group DO Bosch Security Systems Inc 9 10 FO1U169130 02 USER 39 USER 40 USER 41 USER 42 USER 43 USER 44 USER 45 USER 46 USER 47 USER 48 USER 49 USER 50 USER 51 USER 52 USER 53 USER 54 USER 55 USER 56 USER 57 USER 38 USER 59 USER 60 USER 61 USER 62 USER 63 USER 64 USER 65 USER 66 USER 67 USER 68 USER 69 USER 70 USER 71 USER 72 USER 73 USER 74 USER 75 71 SE Ke G Q Q lt q gt C TV gt 0 LL G Ze O N gt F A User Token Worksheet User 039 to 075 D9412GV3 D7412GV3 D9412GV2 D7412GV2 Only Sub User 3 Card Data Site Sub User 2 Card Data A Sub User 1 Master ID 0 Card Data Site ES User Bosch Security Systems Inc 9 10 FO1U169130 02 72 D1265 Owner s Manual Appendix User Passcode Worksheet User 076 to 114 101 249 D9412GV3 D9412GV2 only User Name USER 76 USER 77 USER 78 USER 79 USER 80 USER 81 USER 82
33. S ON Menu nee AIAST After the exit delay time expires the display changes to idle armed text To disarm your security system enter your personal passcode and press ENTER 19 D1265 Owner s Manual Part Il System Commands Master Arming all Areas If you prefer you might use the Master Arm command in the function list Press the Menu button to access the function list configured in the keypad 1 Ensure your keypad shows idle text AREA 1 WAREHOUSE Al AREA IS OFF CATA age O ea O O OS 2 Press the Menu button to enter the function list then press the Next button repeatedly When you reach the Master Arm button press it Master Arm 3 Press the button The display might prompt you to enter your passcode The passcode is shown as asterisks when entered Enter passcode then press ENTER Exit s a E E GEL i Aii 5 Ifmore than one area is configured the system gives the option to arm all areas with Master Arm All To arm all areas proceed to Step 9 AREA 1 WAREHOUSE Arm Area 1 O o o oa 6 To arm a selected area press Next until the desired area appears Area name text along with Arm Area 7 Then press Arm Arm 8 The next available area appears with the option to arm it Every time the Next Previous or Arm buttons are pressed the display scrolls to the next unarmed area 20 10 11 To arm all available are
34. TWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS Bosch Security Systems Inc 9 10 FO1U169130 02 45 D1265 Owner s Manual Part Ill Advanced Commands Delete User CMD 5 3 This function allows a user to be deleted This function deletes the passcode Master access card token and all sub user access cards tokens associated with the user number Ensure your keypad shows idle disarmed text 2 Press the CMD button The display shows System Command System Command 000005 000005 3 Press the 5 button and then the 3 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Delete User button press it 4 The display changes to show Enter user to be deleted Delete user 3 Are you sure Yes hei EXIT NO la 848 GG cs O 8 O O 0 CE Enter the user number not the passcode 123 is as an example Press the ENTER button 5 Ifthe user number entered is a valid user in the system the display shows Delete User 3 Are you sure Delete user 3 Are you sure Yes I Exit NO GES 3 is used as an example 46 If the user number entered
35. USER 83 USER 84 USER 85 USER 86 USER 87 USER 88 USER 89 USER 90 USER 91 USER 92 USER 93 USER 94 USER 95 USER 96 USER 97 USER 98 USER 99 USER 100 USER 101 USER 102 USER 103 USER 104 USER 105 USER 106 USER 107 USER 108 USER 109 USER 110 USER 111 USER 112 USER 113 USER 114 Bosch Security Systems Inc 9 10 FO1U169130 02 73 D1265 Owner s Manual Appendix User Token Worksheet User 076 to 114 D941 2GV3 D741 2GV3 D941 2GV2 D7412GV2 Only 101 249 D9412GV3 D9412GV2 only User Master ID 0 ID 0 Cam mm ml IL os J os oso os os os os os oss os 088 aof pion S ml os IO aaf O of a ar poo og IO pio po a o Ir a puis ef 74 Sub User 1 Sub User 2 Sub User 3 m AN Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Appendix User Passcode Worksheet User 115 to 150 101 249 D9412GV3 D9412GV2 only User User Area Authority HH Passcode Group 3 4 5 6 User Name USER 125 USER 126 USER 127 USER 128 USER 129 USER 130 USER 131 USER 132 USER 133 USER 134 USER 135 USER 136 USER 137 USER 138 USER 139 USER 140 USER 141 USER 142 USER 143 USER 144 USER 145 USER 146 USER 147 USER 148 USER 149 USER 130 Bosch Security Systems Inc 9 10 FO1U169130 02 75 D1265 Owner s Manual Appendix User Tok
36. View Memory PERENE EAS Mele Mesi Reset Sensors 0000052 0000053 Watch Mod Press the CMD button and then the one or two digits Special Alert shown in Table 2 to perform the function When you use a command to perform a function the displays in the function list below do not appear at your keypad Perimeter Partial Special Alert Some commands listed in Table 2 might CCCECECCCCCCCC EEE Bypass a Point not be available Contact your security company for more information Unbypass a Point Some commands listed below might not be available Contact your security company for more information Bosch Security Systems Inc 9 10 FO1U169130 02 15 D1265 Owner s Manual Part Il System Commands Passcode Protected Commands and Turning the System Off Disarming Functions Entering your personal passcode turns off your security system When the system is turned on you must enter through a designated entry door to prevent an instant alarm condition Opening the door starts entry delay time and the keypad emits a pulsing beep tone to remind you to turn the system off Enter your passcode Commands and or Functions within your system might be programmed to require a valid passcode prior to gaining access to that function This ensures that only authorized people have access to specific functions i dis alent E before the delay time expires and the system turns off passcode If you ente
37. ad The D1265 keypad uses up to four rows of 20 characters each to display system messages and graphical buttons used to select a menu and associated functions In addition to system messages and buttons the keypad shows as needed ten numerical buttons 0 to 9 and two function buttons CMD and ENTER Use the CMD button in combination with numeric buttons to perform a function Use the ENTER button to enter your passcode When several events occur the keypad shows each event in order of priority Figure 1 D1265 Touchscreen Numerical Fa ia DA gt A INI 1 EA EN EN EN A Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Security System Basics Part Security System Basics Using the keypad Your security system provides quick access to functions by pressing the CMD button and one or two additional buttons I CMD CMD Another way to access functions is through the function list To access the function list press the Menu button Menu Command ENTER buttons Table 1 D1265 Keypad Buttons Pressing the Previous or Next button while in the Menu List allows you to scroll through the list of functions enabled and programmed by your security company Pressing press the button for the function you wish to perform To exit the function list press the Exit button Use the function list to locate functions you don t use often or that don t have a command number
38. al areas independently Your passcode must have the proper authority level for each area This function works the same as entering your passcode to disarm but allows the Disarm All feature to be included in the function list When an area is turned on armed you must enter a door programmed for entry delay time Opening the door starts the entry delay time Failing to turn off the system before the entry delay time expires or entering through a door not programmed for entry delay time causes an alarm If this happens silence the alarm by entering your personal passcode and pressing ENTER Call your security company to let them know that it is not an emergency situation The display initially shows that the system is armed Press the Menu button to enter the function list Press the Next button repeatedly until you reach the Disarm Menu button then press it Bosch Security Systems Inc 9 10 F01U169130 02 D1265 Owner s Manual Part IV Multi Area Use If entering through a door which is part of an area that is armed the display instructs you to enter your passcode to disarm Enter your passcode and press ENTER The passcode is shown as asterisks when entered and advance from the right side of the display to the left until all the passcode digits are entered Enter passcode Entering Ea AS If the entered passcode is valid the display changes to show Disarm All Disarm All Previous Next
39. an Plan both primary and alternate escape routes Since stairwells and hallways might be blocked during a fire exiting through a bedroom window must be a part of the escape plan If the sleeping area is above the ground floor install a means of safely descending outside the building if one will not already exist As a part of this plan all family members should arrange to meet at a location away from the house such as a neighbor s house so you know that everyone is accounted for Fire 5 Dining Room Escape Routes 6 Living Room Bedroom 7 Smoke Detector Kitchen If it is determined that the alarm was accidentally sounded the bell should be silenced the detectors reset and your security company notified immediately that there is no emergency situation 85 D1265 Owner s Manual Appendix Standard Displays Your keypad uses standard and custom displays to show the status of the security system Many standard displays are described below Your system might not use all of them Descriptions of your custom text follow System Command Shows when you press the CMD button The system is waiting for you to enter a one or two digit number to complete the command System Command 0 0 aa O a Entry Delay Enter Passcode to Disarm When the system is turned on entering through a delay door starts entry delay time The keypad emits a tweedle tone and alternates between Enter Passcode and press the ENT
40. ange Display CMD 4 9 Show Continuous Time Date Use this function to replace the disarmed idle text with a continuous time and date display and to prevent a passersby from knowing the status of your system Any time your keypad has an event to display the time and date display is automatically removed To return the time and date display you must perform this function again 1 Ensure your keypad shows idle disarmed text 2 Press the CMD button The display shows System Command System Command TTT HE a 0 8 00 3 Press the 4 and then the 9 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Change Display button press It Change Displ 4 Select Time Date Display The display will return to idle and the area status will be replaced with the Time and Date The Bright Display and Dim Display options are not supported on the D1265 keypad 42 Extend Closing CMD 5 1 Your system might be programmed to expect you to arm within a scheduled closing window which is a duration of time that is programmed by your alarm company Your system might also be programmed to automatically arm at the end of the window CMD 51 lets you extend the scheduled closing window time either prior to the closing window time or during the clos
41. ar Display button Bosch Security Systems Inc 9 10 FO1U169130 02 11 D1265 Owner s Manual Part Security System Basics Burglary Alarms Burglary alarms are the second priority When a burglary point activates while your system is armed your keypad emits a steady high pitched burglary tone The tone sounds for the time set by your security company The keypad display shows the number of burglary points activated the message Enter Passcode to silence alarm and then custom text for each activated point AREA 1 WAREHOUSE 1 Alarm Enter Passcode to o 8 8 0 8 KB 0600063 If there is more than one point causing an alarm the display shows each point for 3 sec before showing the next one When the last alarm is shown the next display is the first alarm Silencing Burglary Alarms Entering a personal passcode with the proper authority level silences a burglary alarm and disarms the system if it was armed The system now shows Alarm Silenced and then the number of points in alarm ALARMS and the custom text of all the points in alarm in ascending numeric order by area AREA 1 WAREHOUSE 1 Alarm P5 FRONT DOOR 04108003 Entering CMD 4 clears the scrolling point text from the display The Alarm Silenced message continues to alternate with idle text as a reminder that it is still possible to view the text of the points in alarm by using the View Alarm Memory function refer to View Alarm Me
42. as press the Arm button when the display reads Master Arm All Master Arm All Previous Next Gi agg Li Y 00000 The display changes to show that all authorized areas are arming The display shows Exit Now exit delay time remaining Exit Now 16 seconds remaining a El El EL a y E El Y EE After the exit delay time expires the display changes to idle armed text To disarm your security system enter your personal passcode and press ENTER The display changes to show that all the areas are disarmed The display returns to idle text Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Il System Commands Master Arm Instant CMD 1 1 Use this function to turn on a single area both perimeter and interior without delays When entering CMD 11 remember that the second 1 must be pressed within 2 sec after pressing the first 1 The menu entry Master Arm Inst is different in that it allows all or selected areas to be armed instantly M CMD 11 does not comply with SIA CP 01 IN Standard Using the CMD 1 1 command only instantly arms the area where the keypad has been assigned For example if the D1265 is assigned to Area 1 only Area 1 is armed when CMD 1 1 is pressed Ensure your keypad shows idle text 2 Press the CMD button The display shows System Command System Command 000008 lt 0000052 3 Press the 1 butto
43. button The display shows System Command System Command oO 3 Press the 5 button and then the 5 button 47 D1265 Owner s Manual Part Ill Advanced Commands 48 If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Change Passcode button press it Change Passcode You are prompted for your passcode As soon as a number is pressed Entering appears on the third line next to the asterisks The passcode is shown as asterisks when entered and advance from the right side of the display to the left until all passcode digits are entered Enter passcode Entering if EXTE j 5 8 8 0 8 Ea O 0 8 O 0 perc The display changes to Enter new passcode Enter the new passcode As soon as a number is pressed Entering appears on the third line next to the asterisks Enter new passcode EXIT MD 0008003 The passcode is shown as asterisks when entered and advance from the right side of the display to the left until all passcode digits are entered Press the ENTER button If a duplicate passcode is entered the keypad momentarily reads Passcode is already in use Please try again Passcode is already in use Please try again If the new passcode is valid the display changes to Enter new passcode again Enter
44. e walk tested regardless of the type of point For D7412GV3 D7412GV2 and D7212GV3 D7212GV2 Control Panels this function must be added to the keypad s menu Contact your security company for more information Default Text This command shows the current state of the area for 3 sec before returning to idle text Keypad Programming This optional command is only included in this menu when enabled and when all areas are disarmed Access is restricted to the Service User only Through this menu you can change a limited selection of system configuration parameters Consult your security company for details Ensure your keypad shows idle disarmed text Press the 9 button twice Press the ENTER button The display changes to show the service menu Service Walk Test appears on D9412GV2 and D9412GV3 control panels only 57 D1265 Owner s Manual Part Ill Advanced Commands Using View Log 1 2 58 Press the View Log button The display changes to Enter start date Press the Go to last event button to go to the last event in the log Press the Exit button to exit this function and return to idle text Enter the start date in the form of mm dd For example to enter 7 14 as the start date press0 7 1 4 Once you start entering digits the Go to last event button is replaced with the ENTER button Press the Exit button to exit this function and return to idle text Press the ENTER button If the date ente
45. e 12 Silencing Burglary Alarms iii 12 Fire Trouble and Fire Supervisory Events 12 Silencing Fire Trouble and Fire Supervisory conditions CR O OTTO 12 Special Fire Trouble and Fire Supervisory Display 12 Viewing Fire Trouble and Fire Supervisory Conditions lle 12 Non Fire Trouble and Supervisory Events 13 Silencing Non Fire Trouble and Supervisory Events 13 Viewing Non Fire Trouble Events 13 Special System Trouble Display in 13 Events Cleared from the Keypad Are Not Lost 13 Entry Delay Tone and Display ii 13 Exit Delay Tone and Display 13 Button Press Checking Tones n 13 Silencio an Alani dt 13 To Silence an alarm ult 13 How Your System Reports Alarms 14 Part II System Comma nd ccccccccscscsesccoscceess 15 Passcode Protected Commands and Functions 16 Turning the System On LArmgng iii 16 To Turn Your Security System On Arm 16 Turning the System Off Disarming 16 To Turn Your Security System Off Disarm 16 Turning On the System Arming With a Duress PASCO aa 17 Bosch Security Systems Inc 9 10 FO1U169130 02 Turning On the System Arming With Doors or WindoWs OPE 17 Master Arm CMD 1 aaa 19 Descrip 19 Using Master AT in da ET tao sit 19 Master Armninp all Areas 20 Master Arm I
46. e of flammables overloaded Not even the most advanced security system can guarantee protection against burglary fire or environmental threats All security systems are subject to possible compromise or failure to warn for a variety of reasons including but not limited to the following e D streng or horns are placed outside the hearing electrical circuits or other types of hazardous range of people in remote areas of the building or conditions in areas which are frequently closed off they do e If phone lines are from service reports from the not provide the intended protection security system to the Security Company cannot o If intruders gain access through unprotected points be sent unless there is an alternate means of of entry the system will not detect their entrance communication Telephone lines are vulnerable to e If intruders have the technical means of bypassing compromise by several means jamming or disconnecting all or part of the Inadequate maintenance and failure to test are the system they are not detected most common causes of alarm failure It is strongly e Ifthe AC power supply is OFF and the back up recommended that you test your system once a week battery 1S either missing or dead sensors will not to be sure that all system components are working detect intrusion properly 84 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Appendix Although having a security system might ma
47. e start of the alarm that a passcode entry aborts the transmission of the alarm report Alarm Aborted shows if this occurs Exit Delay Tone and Display After you arm your system the keypad emits a repeating beep tone shows Exit Now And counts down the exit delay time During the last 10 sec of the Exit Delay time the keypad will emit a more urgent tone Exit Now 16 seconds remaining Button Press Checking Tones Valid Entry If you press an appropriate button for the function or entry you desire the keypad emits a muted beep tone indicating it accepted your button stroke Invalid Entry A flat buzz tone sounds when you perform a function that is not allowed or when the keypad has no information to display Silencing an Alarm The audible alarm sounds for a specific period of time before it automatically shuts off If an alarm occurs and you want to silence the siren before the time expires simply enter your personal passcode and press ENTER To Silence an alarm Enter your passcode and press ENTER 13 D1265 Owner s Manual Part Security System Basics How Your System Reports Alarms Your security system might be programmed to automatically seize your telephones when sending reports to your security company Once the report is completed your security system restores the telephone line to normal operation check with your security company Other methods of communicating alarm conditi
48. ed later in this manual To Turn Your Security System On Arm 1 Enter your passcode and press ENTER 2 After you arm your system the keypad emits a repeating beep tone shows Exit now seconds remaining and counts down the exit delay time Exit Now 16 seconds remaining 16 Bosch Security Systems Inc 9 10 FO1U169130 02 Turning On the System Arming With a Duress Passcode Your passcode might have a special duress feature that can be your personal passcode with its last digit increased by one or two digits Alternately some systems might have a specific passcode designated as the Duress disarm passcode Consult your security company for your security system s configured duress option For example if your passcode is 1234 your duress passcode might be 1235 or 1236 If an intruder demands that you arm or disarm the security system you can use your duress passcode The duress passcode arms or disarms the system and sends a duress report to your security company There is no alarm tone or visual indication at the premises that the report is sent Check with your security company before attempting to use this feature Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Il System Commands Turning On the System Arming With Doors or Windows Open If a protected door or window is open you might have the option of force arming with that point faulted Faulted points
49. ems Inc 9 10 FO1U169130 02 6 Move through this list by pressing the Next Pt button P3 DELAY Area 3 Pt 3 Normal HW Next Pt l Prev Pt A ie ee oe G Si i oc 00000 The display changes to show the information for that point Press the Exit button to return to the points remain to be tested screen before continuing with the walk test 7 When all points have been tested 0 points remain to be tested is shown Press the Exit button The display momentarily shows All points have been tested The display then shows idle text Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Il System Commands Reset Sensors CMD 4 7 Description Detection devices such as smoke detectors and shock sensors must be reset after being activated This function momentarily removes power from these sensors to reset them Using Reset Sensors 1 Ensure the display shows disarmed idle text 2 Press the CMD button The display shows System Command System Command If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Reset Sensors button press It Reset Sensors 4 The display shows for approximately 15 sec Sensors resetting Please Wait 000005 While the sensors reset the keypad resets
50. en Worksheet User 115 to 150 101 249 D9412GV3 D9412GV2 only User Master ID 0 Sub User 1 Sub User 2 Sub User 3 ES E IE ue A FARETE hoo A po 3 a e pp ap SAA A SO POS e AAA End RADXUSR1 Handler LATA E LL py E E WI Dodo dj Doo PMN py py NANA PO MI DEM or kt FP Il y py Do ee o LL o LL T_T O l o LL py OO OM O ee y y o Lo o LL 76 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Appendix User Passcode Worksheet User 151 to 189 101 249 D9412GV3 D9412GV2 only User Name USER 151 USER 152 USER 153 USER 154 USER 155 USER 156 USER 157 USER 158 USER 159 USER 160 USER 161 USER 162 USER 163 USER 164 USER 165 USER 166 USER 167 USER 168 USER 169 USER 170 USER 171 USER 172 USER 173 USER 174 USER 175 USER 176 USER 177 USER 178 USER 179 USER 180 USER 181 USER 182 USER 183 USER 184 USER 185 USER 186 USER 187 USER 188 USER 189 Bosch Security Systems Inc 9 10 FO1U169130 02 77 D1265 Owner s Manual Appendix User Token Worksheet User 151 to 189 101 249 D9412GV3 D9412GV2 only User Master ID 0 Sub User 1 Sub User 2 Sub User 3 HHT Card Data Site Card Data Site Card Data Ca KH BR SES IO le la EY di Doo dd el Li y tas Lo sil 1 i 1 E ES NG ee EE EE i Il e ci At est Pe
51. f your passcode gives you authority to all areas supported by the control panel but the keypad you re working with is limited in scope to areas 1 and 2 then you only can move to either area l or area 2 Upon moving to another area the range of tasks you might perform depends upon the keypad you re working with Once you have performed a task such as Turning the Area On the keypad reverts back to its programmed area after 10 sec Thus only one task can be performed in another area at a time 1 Ensure your keypad shows idle disarmed text 2 Press the CMD button The display shows System Command System Command 000005 a a 8 00 3 Press the 5 button and then the 0 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Move To Area button press it 4 You might be prompted for your passcode If so enter your passcode and press the ENTER button It appears on the display as asterisks Enter passcode Entering E 0000 000046 The Exit button quits this function and return to idle text 5 The keypad shows the Area Name Text of each area that falls within the scope of the key pad and authority level of the user if applicable 62 If the user s authority level will not permit access to a certain area and that area Is not w
52. fer you might use the function list in place of Steps 7 through 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Perimetr Arm Delay button press It Perimetr Arm Delay 22 The display shows Exit Now seconds remaining exit delay time remaining Exit Now 16 seconds remaining 828823 ea KEEB 0800008 After the exit delay expires Perimeter On Delayed is shown AREA 1 WAREHOUSE Perimeter On Delayed m Help Menu o El Ed EY E KEEB a a a 00 To disarm your security system enter your personal passcode and press ENTER The display then returns to idle text Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Il System Commands Silence Trouble Sound Clear Trouble Display CMD 4 Description Use CMD 4 to silence the trouble sounder during system events This command also clears system messages from the display If an alarm has occurred and was silenced the Alarm Silenced display continues to scroll to remind you that cleared events can be seen with the View Alarm Memory function Refer to View Alarm Memory CMD 4 0 on page 23 for more information Using CMD 4 The display shows disarmed idle text 1 Press the CMD button The display shows System Command System Command 2 Press the 4 button 3 The keypad sounder is silenced B
53. function list Press the Next button repeatedly When you reach the Perimeter Arm Inst button press it Perimeter Arm Inst 2 1 D1265 Owner s Manual Part Il System Commands 4 The display shows Perimeter On Instant AREA 1 WAREHOUSE Perimeter On Instant i Help Menu mm 905000 a 000090 After arming the perimeter without delays you cannot enter or exit the premises without disarming the system Opening a perimeter door before disarming generates an alarm If this happens silence the alarm by turning your system off and call your security company to let them know that it is not an emergency situation Perimeter Delay CMD 3 Turn On the Perimeter With Delays Description In residential systems this function allows you to only arm the perimeter and exit through a door programmed for exit delay The interior of the building remains disarmed People or pets are free to move throughout the interior of the premises This function is also useful in commercial systems when you are working before or after business hours and wish to have the perimeter armed Other system users can enter through doors programmed for entry delay which starts the entry delay sounder and countdown Using Perimeter Delay Interior points are not armed with this command and might remain faulted while arming with COMMAND 3 l Press the CMD button 2 The display shows System Command 3 Press the 3 button If you pre
54. g options Exit Now 15 e Previous button scrolls to the last area that seconds remaining can be armed based on passcode and authority level e Next button scrolls to the first area that can em ch ea a ere be armed based on passcode and authority level e Arm button arms all areas based on passcode Keypad scope and or your authority level limit and authority level the actual number of areas you might turn on e Exit button returns the display to idle text For example if you have authority to arm all areas but the scope of the keypad you re using Master Arm All is limited to areas 1 2 and 5 then you only can Previous Next turn on areas 1 2 and 5 Exit Arm Y 3 Ifa point is faulted door or window open for D Es eae 4 5 CMD CMD example Refer to Turning On the System TA Gace ca cme STE Arming With Doors or Windows Open on page 17 q CA ER ER 0 FENTER pas D a E ES D ENTER for more information 5 Ifthe Next button is pressed the first area that can be armed based on passcode entered and Faulted Points in Other Areas user authority level is shown AREA 1 If there is a faulted point in an area you select other WAREHOUSE is used an example of the first than the one you are in Check Area 1 1 is used as area that can be armed an example here appears for 3 sec and then the displ t to th di d idle text 6 Pressing the Arm button causes AREA 1 KE RR AA a WAREHOUSE is n
55. ge the user s Authority Level e Name Press the Name button to change the user s name e Card Press the Card button to change the user s card e Sub User Press the Sub User button to change the user s sub user status Add Change Menu Passcode NEVIS Level Card uu Exit Sub User 844 GG KB If your system does not have door access control available in the control panel this menu allows the following User items to be changed e Name Press the Name button to change the user s name e Passcode Press the Passcode button to change the user s passcode e Level Press the Level button to change the user s Authority Level 90 2 Add Change Passcode 1 Pressing the Passcode button allows you to add change a user s passcode M User 3 is used here as an example h The display changes to User 3 Add Change a passcode for this user Press the Yes button to add a new passcode Go to Step 3 Pressing the No button advances to Add Change Level if the control panel does not have access control or Add Change Access Card if the control panel has access control The display changes to Enter new passcode Enter the new passcode As soon as a number is pressed Entering appears on the third line next to the asterisks Enter new passcode agaln Entering gt EXIT 00000 aa 000 The passcode is shown as asterisks when entered and advance from the right side of the display to the lef
56. he 1 button to send a test report Press the 4 button then the 2 button to send a status report If you prefer you might use the function list in place of Steps 3 and 4 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Send Report button press It Send Report Another menu appears allowing for the selection of sending a test report Test Rpt or a status report Status Rpt Press either button 5 The keypad shows Sending report Please wait until the report is transmitted to the security company Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Ill Advanced Commands 6 When the transmission is complete the keypad shows Report sent for 5 sec Report Sent ZITAT The display returns to idle text 7 If the test or status report does not successfully transmit to the central station the keypad might sound a trouble tone and display Comm Fail Route Grp 1 4 after numerous unsuccessful attempts Bosch Security Systems Inc 9 10 FO1U169130 02 Remote Program CMD 4 3 Description This function allows the user to initiate Remote Programming Software RPS sessions When the phone is ringing at the control panel the user initiates this function to have the control panel seize the line Your security company can remotely program your security system using the
57. he Menu button to enter the function list Press the Next button repeatedly When you reach the Unbypass a Point button press It Unbypass a Point 4 You might be prompted for your passcode It appears on the display as asterisks Enter passcode Entering 5 The display changes to show Enter point number or press next key Enter point number or press next key Elke Next EES Bosch Security Systems Inc 9 10 FO1U169130 02 If digits are pressed the display shows Enter point number As soon as a digit button is pressed the display changes to Entering point number is the point number that was entered Entering point number 2 SR 228288 KEEB GaGa ai If you know the point number you wish to unbypass enter the number and press the ENTER button If you don t know the number of the point you wish to unbypass you can view the list of devices that can be unbypassed by pressing the Next button Continuously pressing Next scrolls through the available points that are currently bypassed When the point text of the point you wish to unbypass appears press the Unbypass button P3 DELAY 1s bypassed Previous Unbypass l poe 0 8 ES 0 O ES One of the following messages shows P3 ENTRY DELAY is used here as an example P3 ENTRY DELAY is now bypassed indicates the point was successfully bypassed P3 ENTRY DELAY is now bypassed 824 GG KB Invalid poin
58. he start time and return to idle text Enter the new time using a 12 hour HH MM format Example If the desired time is 12 34 press 1 2 3 4 Press the AM button to select AM Press the PM button to select PM The display changes to show the new start time briefly before returning to idle text Press the Accept button to accept the Close Start time 43 D1265 Owner s Manual Part Ill Advanced Commands Chg Skeds CMD 5 2 Description A Sked is a function programmed to be performed automatically at a scheduled time by your security system You can change the scheduled time for some functions disable the Sked and thus prevent it from automatically happening or restart a previously 5 disabled Sked Contact your security representative to determine what Skeds might be programmed for your system 6 To change a Sked s time enable a Sked or disable a Sked follow the procedure below to first select the Sked from a list of Skeds programmed for your system Using Chg SKEDS 1 Ensure your keypad shows idle disarmed text 7 2 Press the CMD button The display shows e System Command System Command 000005 04 O 0 EB 3 Press the 5 button and then the 2 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the
59. hen returns your telephone to normal service and your display to idle text For systems with a network connection O My system uses an IP Address and network connection for Unattended Remote Programming Ensure your keypad shows idle disarmed text 2 Press the CMD button The display shows System Command System Command 82808 0 GKB a 0 a 00m 3 Press the 4 button then the 3 button Bosch Security Systems Inc 9 10 FO1U169130 02 If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Remote Program button press It Remote Program Press ENTER Select RPS via Network Do one of the following O My system uses the default port number for network connection Press Use Port and then skip to Step 7 a My system uses an alternate port number for network connection RPS connecting B O B O OE Select the Enter Port Number option and enter the port number specified The security system now connects to the IP Address specified for network connection during the remote programming session At the conclusion of the programming session your system sends a report to the security company and then returns the display to idle text Bosch Security Systems Inc 9 10 F01U169130 02 D1265 Owner s Manual Part Ill Advanced Comma
60. in indicates that the entered point doesn t exist and the display returns to allow another point to be entered Invalid point Please try again a jr nnt A AL a aS ie a EN EA fa ee ESTE 0000053 No additional points indicates that there are no more points that can be bypassed No add1tional points A A EA ee ET 04108003 32 7 Ifthe bypassed point is a Fire Point the message Fire Point Bypassed begins alternating in the display with Al Area Is Off AREA 1 WAREHOUSE Fire Point Bypassed Help a on EN Menu Ge EA E oo a 0 GB 8 Ifthe bypassed point is a 24 hour point the message 24hr Point Bypassed begins alternating in the display with A1 Area Is Off AREA 1 WAREHOUSE 24hr Point Bypassed Help Menu Lina E ga fg ETR O O Gm A E aaa Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Ill Advanced Commands Unbypass A Point CMD 0 0 Description Unbypassing a point is a way to return a bypassed point to the security system so that it can once again respond to trouble and alarm conditions Using Unbypass a Point 1 Ensure the display shows disarmed idle text 2 Press the CMD button The display shows System Command System Command a 0 8 906 3 Press the 0 button twice If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press t
61. in the keypad scope and for which your personal passcode has authority Given that you have access to areas beyond the local area the means of accessing the various system functions depends upon the specific function For some functions the keypad allows you to select the area or point in which to perform the function These selectable functions are e Disarm e Master Arm Area e Bypass A Point e Unbypass A Point Another group of functions might automatically work in all areas in which you have passcode authority and which are within the scope of the keypad These are e Turning Off Multiple Areas with a Passcode e Disarm All e Master Arm All e View Alarm Memory e Walk Test e Reset Sensors e Add Passcodes e Fire test e View Point Status e View Area Status Some functions might be area specific To perform these functions you must first use the Move To Area function CMD 50 to gain access to the desired area Once in the desired area you can perform the functions you wish Area specific functions include e Perimeter Instant Perimeter On Instant e Perimeter Delay Perimeter On Delay e Perimeter Partial Perimeter On Partial e Extend Closing 60 e Watch Mode e CMD 7 e CMD 9 A last group of functions don t relate to specific areas and are thus system wide These are e Send Report e Remote Program e Change Time Date e Change Skeds e Delete Passcodes e Change Relays e Change Passcode
62. inder tone to begin This time is the new beginning of the closing window The time length of the closing window is programmed by your security company and remains fixed When you hear the warning you can e Press the Silence button silences the beep and clear the message for 10 minutes e Leave before the end of the closing window e Stay past the scheduled end of the closing window by using CMD 51 to extend the closing window Extending the closing window will not effect the amount of time available to close For example if your closing window starts at 4 00 p m and stops at 4 30 p m and you extend closing to 5 00 p m the closing window is now between 5 00 and 5 30 p m 1 Ensure your keypad shows idle disarmed text AREA 1 WAREHOUSE Al AREA IS OFF oT i Help i Menu 0 O O O BEN 000003 2 Press the CMD button The display shows System Command System Command 824 GG cs a a 8 00m 3 Press the 5 button and then the 1 button Bosch Security Systems Inc 9 10 FO1U169130 02 If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Extend Closing button press it Extend Closing The display changes to show the current start time Press the Change button to change the start time Press the Accept button to accept t
63. ing a point more than once will not increment the test count However the keypad emits a brief tone and shows the point text each time you fault the point allowing you to test multiple devices assigned to one point 6 When the point has been tested the display changes to show SMOKE DETECTOR tested 96 7 During the Fire Test you might want to refer to the points that remain untested by pressing the View untested pts button View untestec The display shows 77 pts untested 6 pts untested Next PT Prev PrE EETTT7 Og HH a aw Press the Point information button to see information about specific points that have not yet been tested The display changes to show the information for that point Move through this list by pressing the Next Point button Press the Exit button to return to the points remain to be tested before continuing the Fire Test When all 24 hour points have been tested 0 points remain to be tested is shown Press the Exit button The display momentarily shows All points have been tested before returning to idle text Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Ill Advanced Commands Display Rev CMD 5 9 1 Ensure your keypad shows idle disarmed text 2 Press the CMD button The display shows System Command System Command If you prefer you might use the function list in place of Steps 2 and
64. ing window time Use this function when you expect to stay past the scheduled end of the closing window Your alarm company sets the length of time prior to the start of the closing window in which you are allowed to extend the closing window Close window is not currently active shows during the time when the keypad won t allow the window to be extended Close window is not currently active 00000505 At the beginning of the closing window the keypad beeps and shows Please Close Now to remind you to arm your system It remains on the display until you arm the close window ends or you extend closing Mi The closing window can only be extended once the window has started Alarm or trouble messages replace this message in the event of an alarm or trouble condition AREA 1 WAREHOUSE 2 Fire Supervisory SMOKE DETECTOR Silence 00500505 Pressing the Silence button silences the beep and clear the message for 10 minutes If the alarm or trouble condition clears before the end of the close window Please Close Now message returns to the keypad display Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Ill Advanced Commands If you have not armed or extended closing the Please Close Now message and beep reappears after 10 minutes Your alarm company sets the length of time for the closing window To extend the window enter the new time at which you would like the rem
65. ins faulted Fire Trouble appears in the keypad s display The Fire Trouble display persists until the detector causing it is restored to normal Viewing Fire Trouble and Fire Supervisory Conditions After pressing CMD 4 or the Silence button Fire Trouble continues to automatically scroll through the display To view the faulted fire points press any numeric key then press Next to scroll these displays manually Events scroll from oldest to newest Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Security System Basics Non Fire Trouble and Supervisory Events When a trouble event occurs your keypad might be programmed to emit three warble tones then a pause repeatedly If the system was armed the keypad display shows the number of non fire trouble events or non fire supervisory events and then custom text for each activated point Silencing Non Fire Trouble and Supervisory Events Pressing CMD 4 or the Silence button silences and clears Trouble and or non fire Supervisory conditions In addition to this entering a personal passcode with the proper authority level silences a trouble and disarms the control panel if it was armed If you wish to review these cleared troubles press CMD 40 Viewing Non Fire Trouble Events After pressing CMD 4 or the Silence button press any numeric button to view the faulted points Press Next to scroll these displays manually if you wish Events
66. ire bell for 2 sec The AC is disabled for 4 minutes in order to test the system s battery power If the battery cannot maintain the system for the 4 minute period the keypad appears to power off If this happens contact your security company At the end of the 4 minute period AC is returned to the system and the control panel restores A message is sent to your security company upon initiation and completion of the Fire Test During the Fire Test no 24 hour alarms are sent to your security company If there is no activity on the system for 20 minutes the system automatically exits from the Fire Test Any 24 hour points left in a faulted condition at the end of the test are automatically removed from service by bypassing them Once the 24 hour device is reset to normal use the Unbypass command refer to Unbypass Ba GG E a a a O O E 3 Press the 5 button and then the 7 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Default Text button press it 4 The current state of the area is shown for 3 sec before returning to idle text Bosch Security Systems Inc 9 10 FO1U169130 02 A Point CMD 0 0 on page 33 to return them to Service Using Fire Test 1 Ensure your keypad shows idle disarmed text 2 Press the CMD button The display
67. is not a valid user in the system the display shows This user is currently not in use This user 15 currently not in use m Exit 22 8 G G cm Press the Yes button to delete the user The display briefly shows that the user has been deleted before returning to idle text 3 is used as an example User 3 deleted gg The user text is not deleted when deleting a user To modify a user s text refer to Add Change User CMD 5 6 on page 48 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Ill Advanced Commands Change Relay CMD 5 4 Your security company might program relays for automatic control and or control from your keypad of devices such as premises lighting or entry gates Contact them for further information regarding the use of relays in your security system 1 Ensure your keypad shows idle disarmed text 2 Press the CMD button The display shows System Command System Command If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the CHG RELAYS button press it 4 The keypad display changes Change Relay Enter relay number Valid entries are 1 to 128 depending how the system is configured Change Relay Enter relay number EX1T TC 0000465 Enter the relay number
68. isks It appears on the display as asterisks Enter passcode Entering it 0 ta ta O O Gr Press the ENTER button Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Ill Advanced Commands The display changes to Enter new passcode again Enter new passcode again Entering E rp Enter the new passcode again Press the ENTER button If a duplicate passcode is entered the keypad momentarily reads Passcode is already in use Please try again If the passcode matches the previously entered passcode the display changes to Passcode changed Passcode changed Ga a o O E If the passcode does not match the keypad emits an error tone and shows Passcode not changed Press the Exit button to return to the Add Change Menu 91 D1265 Owner s Manual Part Ill Advanced Commands Add Change Level 1 92 Pressing the Level button allows you to add change a user s authority level The display changes to User 3 Add Auth Level for this user User 3 Add Auth Level for this user Yes 00000 Press the Yes button to add an Authority Level Press the No button to advance to Add Change Passcode if the control panel does not have access control or to Change Sub User ID if the control panel has access control Press the Exit button to exit from this menu and return to the Level changed display refer to Step 6 The display changes to Is
69. ither of these buttons causes the currently underlined character to change the previous or next character in the list The available characters are A Z 0 9 and 5 and Left POS Right Pressing either of these buttons causes the cursor of the currently underlined character to move left to the previous position in the name or right to the next position in the name Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part III Advanced Commands Another option is to use the numeric buttons to add characters to the text For the buttons with letters pressing the digit allows you to cycle through the letters on the button For instance pressing 2 shows an A Pressing it again shows a B and pressing it a third time shows a C The 0 zero button shows a 0 The 1 button functions like a space bar it puts a space in the current position and advances to the next position Pressing the button shows a list of the letters for each digit Keys l space 2 ABC 3 bEeFcei GhLepbadlkl 6 MNO PQRS 8 TUV Exlt_ Next Fre 04108003 Once the name appears as desired press the Continue button The display changes to New user name is GERRY Is this correct At this point you can accept or reject the changes New user name 1S GERRY Le this correct Co No Yes NO 005000505 Press the Yes button to accept the name and return to the idle text screen P
70. ithin the scope of the keypad or the area is not enabled it will not appear in the display If the area you wish to move to will not appear in this list press the Next button to display additional areas To select an area simply press the button corresponding to the Area Name 6 Moving to AREA 1 WAREHOUSE shows briefly and then the text of the area you have moved to is shown AREA 1 WAREHOUSE is used as an example here 7 You are now able to perform tasks in this area The number of areas to which you can move is limited by the scope of the keypad 8 When you have completed all tasks in the area you have moved to simply allow the keypad to time out and revert to the area from which you started or enter the Move to Area function again Turning On the System Turning on Selected Areas Areas covered in the scope of the keypad can be armed individually by accessing the Master Arm function through the menu Press the Menu button to enter the function list 2 Press the Next button repeatedly until you reach the Master Arm button and then press it Master Arm 3 You might be prompted for your passcode It appears on the display as asterisks Enter passcode Entering a EXIT TEET lt Bosch Security Systems Inc 9 10 F01U169130 02 D1265 Owner s Manual Part IV Multi Area Use 4 The display changes and shows Master Arm 2 The keypad shows the following All with the followin
71. ke you eligible for reduced insurance premiums the system is no substitute for insurance Warning devices cannot compensate you for loss of life or property Fire Safety and Evacuation Residential fire is a leading cause of accidental death Most fire related deaths occur at night when occupants suffocate in their sleep from smoke and toxic gases rather than from burns To help reduce this risk the following program should be implemented 1 Minimize fire hazards Smoking in bed cleaning with flammable liquids such as gasoline leaving children home alone and using unsafe holiday decorations are some of the common causes of household fire 2 Install a fire alarm system The primary purpose of this system is to protect lives by giving the earliest possible warning of danger 3 A smoke detector should be provided to protect each sleeping area in a home Figure 2 and Figure 3 Figure 2 Smoke Detector Locations Plan View o PIT D 6 3 3 1 Smoke Detector 4 Dining Room 2 TV Room 5 Kitchen 3 Bedroom 6 Living Room Bosch Security Systems Inc 9 10 FO1U169130 02 Figure 3 Smoke Detector Locations Elevation View 1 Smoke Detector 2 Bedroom Practice an escape plan Because there might be very little time between detection of a fire and the time it becomes deadly it is important that every member of the family understand how to quickly evacuate according to the pl
72. last area press the Previous button to view the last point in the area You can press the Exit button at any time to exit this function The top line shows the point text The second line shows the area assignment of the current point and the point number The third line shows the points current state Normal Open Short Missing shows the point text Pressing the Next button takes you to the next point in the area whereas the Previous button takes you to the previous point in the area SMOKE DETECTOR Area 1 Pt 2 Norma HW Next Pt EX1t Prev Pt 888 GG cs O a O O 0 aD Refer to Table 5 for more information Bosch Security Systems Inc 9 10 F01U169130 02 D1265 Owner s Manual Part IV Multi Area Use Table 5 Screen Area Definitions Line Area Name Area Pt This displays the customized name for the point This displays the area number This displays the area number the area number This displays point numbers 1 to 127 and 129 to 247 Normal Indicates that the point is not in the faulted state is In an open state is in a shorted state is missing 61 D1265 Owner s Manual Part IV Multi Area Use Move To Area CMD 5 0 With this function you can perform tasks in an area other than the one you re in without having to physically go to that area Your access to other areas is limited by the scope of the keypad and your authority level For example i
73. le here To change the Authority Level Enter a new authority level from 1 to 14 if desired and press the ENTER button Before determining the Authority Level for a user please consult your security company to assist you in selecting the correct authority level Press the Exit button to exit from this menu and return to the Level changed display Repeat Step 4 for each area through Area 8 Once the user s authority level has been verified for Area 8 the display changes to Level changed If the Next button is pressed the display changes to Add Change Sub User ID if the control panel has access control or Add Change Passcode for control panel without access control If the Exit button is pressed the display changes to Add Change User Enter User Add Change User Enter user EXTE Enter Bosch Security Systems Inc 9 10 FO1U169130 02 Adding Changing a User s Name 1 Pressing the Continue button once you enter a user changes the display to Add Change Menu Add Change Menu fPasscode ENNET Leve Card exit Sub User 02 0 E KB a a a a DGE 2 Pressing the Name button changes the display 2 USER 2 Back Char list Fwd Left POS Right Exit Continue a a a 90 3 To change the name use the following buttons USER 2 Pressing this button shows a series of help screens where the keypad can be used to enter specific letters Back char list Fwd Pressing e
74. left until all the passcode digits are entered Enter passcode EXTEU sauce acs ad a 0005 6 Ifthe entered passcode is valid the display changes to show Disarm All 7 Press the Next button to go to the first armed area 8 The display changes to show Disarm Area 1 or the first area that is armed Press the Disarm button to disarm this area A confirmation of the areas disarmed status is shown and then the display advances to the next armed area Press the Next button to scroll through the remaining areas you have the authority to turn off To disarm the area press the Disarm button 9 After turning off all armed areas or pressing the Exit button the keypad s display returns to the idle text for the area you are in 66 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Appendix Appendix Supplementary Information for Adding Passcodes Use the information contained in this Supplement to help you add user passcodes User Authority Levels Your security company uses the information contained on this page to establish authority levels for system users For each of the 1 14 authority levels each keypad function is either enabled E disabled blank or Passcode enabled P A function that is enabled E is available to all users A function that is passcode enabled P is only available to users assigned an authority level that includes that function If you do no
75. lock Door 3 press 3 then press the ENTER button The display changes to show that all the doors are at a normal state except for Door 3 which is unlocked 12U456 7 8 Enter the door number again to return it to the normal mode The display shows the door number again 5 Press the Exit button to leave this function Secure Door 1 IE you wish to unlock an access door to allow free access press the Unlock Door button 40 2 The display reads Secure Door 1 2345678 if all door are at a normal state and are available Secure Door dengem Ae gt select Door and press Enter 0000067 If a door is not at a normal state the number of the door would be replaced with a symbol indicated in Table 3 on page 39 3 Enter the number of the door you wish to secure then press the ENTER button This door is secured and the display changes to reflect the new status of the doors For example if you wanted to secure Door 3 press 3 then press the ENTER button The display changes to show that all the doors are at a normal state except for Door 3 which is secured 12U456 7 8 4 Enter the door number again to return it to the normal mode The display shows the door number again A Press the Exit button to leave this function Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Ill Advanced Commands Access Level 9 After selecting whether to disable or enable
76. m Bosch Security Systems Inc 9 10 F01U169130 02 The type of alarm appears before the point text when there is an alarm There are two types of controlled points perimeter points and interior points Perimeter Points These points usually include all exterior doors and windows of the building Interior Points These points usually include interior forms of burglary detection devices such as motion sensors or inside doors for example 24 Hour Points 24 hour points are always on even when the burglary system is disarmed turned off There are two types of 24 hour points fire points and non fire points D1265 Owner s Manual Part Security System Basics Fire Points Fire points exclusively monitor fire detection devices They are always armed and cannot be disarmed You can Clearly distinguish fire points from other non fire points at the keypad When there is a fire alarm the display shows the following FIRE ALARM is shown on the first line text identifying the point as a fire point is shown on the second line and instructions for silencing the alarm are shown on the third and fourth lines Fire alarms have a unique audible warning signal Non Fire Points Non fire 24 hour points are always armed and cannot be disarmed 8 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Security System Basics Your Custom Display At an idle state means
77. m Points that are not included in the system do not detect intruders and cannot send any reports You can bypass points when an area is disarmed Bypassing a point reduces the level of security and should be used with discretion Points remain bypassed until you unbypass them or some points might return when the area is disarmed refer to Unbypass a Point CMD 0 0 on page 33 You could use CMD 0 to leave a window open over night without initiating an alarm Also refer to Turning On the System Arming With Doors or Windows Open on page 17 Using Bypass a Point 1 Ensure your keypad shows idle text 2 Press the CMD button The display shows System Command System Command 000005 a 0000 3 Press the 0 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Bypass a Point button press it Bypass a Point 4 You might be prompted for your passcode It appears on the display as asterisks Enter passcode Entering iti Bosch Security Systems Inc 9 10 FO1U169130 02 A three to six digit number entered at a keypad to access the system 5 The display changes to show Enter point number or press next key Enter point number or press next key Seli Next 844 GG KB a a O O O CE 6 Ifa digitis pressed the display sh
78. mory CMD 4 0 on page 23 for more information To clear the event memory and remove the Alarm Silenced message from the display press the Clear Display button The display shows the instructions for clearing the message Enter a valid passcode and press the Clear button 12 Fire Trouble and Fire Supervisory Events When a fire trouble or fire supervisory condition occurs your keypad emits three warble tones then a pause repeatedly The system shows the number of fire points that are in a trouble or supervisory condition as well as the point text of the affected points AREA 1 WAREHOUSE 1 Fire Trouble PL FIRE RSS a a O O O Cu Silencing Fire Trouble and Fire Supervisory conditions Pressing CMD 4 or the Silence button silences and clears the Fire Trouble and or the Fire Supervisory conditions In addition to this entering a personal passcode with the proper authority level silences a fire trouble and disarms the control panel if it was armed Use CMD 40 if you wish to review these cleared troubles Some systems might be programmed to automatically re sound the keypad s trouble tone after a period of time if the fire trouble or fire supervisory condition remains Consult your security company for further information Special Fire Trouble and Fire Supervisory Display If you silence the keypad or clear a trouble or supervisory condition for a Fire Point from the display and the fire point rema
79. n Now press the 1 button again The keypad display shows All On Instant AREA 1 WAREHOUSE All On Instant Help 0 O El O El KB o e E El QU Gy 4 To disarm your security system enter your personal passcode and press ENTER Menu Bosch Security Systems Inc 9 10 FO1U169130 02 Perimeter Instant CMD 2 Turn On the Perimeter With No Delays Description Use this function to turn on only the perimeter of your building leaving the interior of the building disarmed This function allows no exit or entry delay time through the perimeter including the designated exit delay door This function is useful in residential systems when everyone is home and ready to retire for the evening You can have the security of an armed perimeter yet move freely throughout the interior of the premises It is also useful in commercial systems when you are working before or after business hours and wish to have the perimeter armed Remember there are no entry or exit delays when you use this function You must disarm turn off the system to enter or exit the premises Using Perimeter Instant Interior points are not armed with this command and might remain faulted while arming with CMD 2 1 Press the CMD button 2 The display shows System Command 3 Press the 2 button If you prefer you might use the function list in place of Steps 7 through 3 to initiate this function Press the Menu button to enter the
80. n presses Pressing any button on the keypad quiets any warning tones If you don t press another button within 7 sec the warning tones resume Priority of Events If more than one event occurs your system sorts them into one of four groups The groups highest priority first are 1 Fire Alarms 2 Burglary Alarms 3 Fire Troubles and Fire Supervisory conditions 4 Non Fire Troubles and Non Fire Supervisory conditions The group with the highest priority scrolls first in the keypad s display Descriptions of the tones and displays for each group and instructions for silencing the tones are included in the descriptions that follow Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Security System Basics Fire Alarms m A S HENN Sale LECCO Fire alarms are the highest priority events When a fire point activates your keypad emits a pulsating high Sean pitched fire tone Evacuate all occupants and investigate for smoke or fire Ensure that all occupants E 2 ea know the difference between the burglary tone and the B Ee 8 E E fire tone The tone sounds for the time set by your The display shows the instructions for clearing the security company message Enter a valid passcode and press the Clear The keypad display shows the point text of the first button point that went into fire alarm and shows the message If a fire trouble still exists the Alarm Silenced En
81. nds Change Time Date CMD 4 5 The time and date in your system must be correct for scheduled events to occur at the correct times Check the time at least once a month to ensure accuracy Use this function to set both the time and date The system uses a 12 hour AM PM format There is the option to continuously display the time and date in place of area status The Time and Date is shown continuously until a new command is entered or the current area s status has changed Refer to Change Display CMD 4 9 on page 42 Time Date Display for more information 1 Ensure your keypad shows idle disarmed text 2 Press the CMD button The display shows System Command System Command 9 O 0 0 0 Ez 0008003 3 Press the 4 and then the 5 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Change Time Date button press it Change Time 4 The display shows Enter new time Enter new time SE Date 00000 0000900 To just change the date press the Set Date button Refer to Step 6 If you input the wrong time press the Exit button to clear the time 37 D1265 Owner s Manual Part Ill Advanced Commands Enter the new time using a 12 hour HH MM format 8 Press the ENTER button Example If the desired time is 12 34 press
82. nstant CMD 1 1 21 Perimeter Instant CMD 22 21 Turn On the Perimeter With No Delays 21 sine E stato or 21 Perimeter Delay CMD 3 22 Turn On the Perimeter With Delays 22 Silence Trouble Sound Clear Trouble Display CMD EE 23 EE ee 23 Usm CMD A er errr rere 23 View Alarm Memory CMD 4 0 23 Using View Alarm Memory EE 23 Walk Test CMD 4 4 iii 24 Reset Sensors CMD 4 7 25 Using Reset Sensor usina 25 Watch Mode CMD 6 i 26 Usmo Match Mode 26 Entering Watch Mode iii 26 Beating Watch Modesto 26 Perimeter Partial CMD 8 27 Partially Turn On the Perimeter 27 Using Perimeter Partial A cali 27 Special Alerts CMD 7 and CMD 9 28 Usina CMD Tdi ans 28 Usine Command Oria 29 Part III Advanced Commands cccsssccsscsssssscees 30 Advanced Commande 30 Bypass a Point CMD FOl irsinin 31 DEscripionm arcata 31 Usine Bypass a Ponso e 31 Unbypass A Point CMD 0 0 33 Descrip ON ralla 33 Usine Unbypass a Pombia nt 33 Send Report CMD 4 1 or All 34 JOSE PU rs 34 Re teaa aa ap 34 Remote Program CMD 4 3 35 DESC PU 35 For systems without a phone number 35 For systems with a phone number configured 36 For systems with a network connection 36
83. ntly arm all the areas that are within the scope of the keypad press the Arm button This display changes to show On Instant indicating that the areas are armed AREA 1 WAREHOUSE All On Instant Data WU o dg E OD O EB Bosch Security Systems Inc 9 10 FO1U169130 02 Turning Off the System Turning Off Multiple Areas with a Passcode This function is useful for turning off multiple areas with a few button presses It is quicker than disarming several areas independently Your passcode must have the proper authority level for each area After enter your passcode the following shows Disarm 12345678 All user authorized areas are now disarmed Not all area number might appear due to what areas are in the scope of the keypad Disarm 8 areas All user authorized areas are now disarmed sagas CB G A O O O CE When an area is turned on armed you must enter a door programmed for entry delay time Opening the door starts the entry delay time Failing to turn off the system before the entry delay time expires or entering through a door not programmed for entry delay time causes an alarm If this happens silence the alarm by entering your personal passcode and pressing ENTER Call your security company to let them know that it is not an emergency situation Turning Off Multiple Areas with Disarm All This function turns off multiple areas with a few button presses It is quicker than disarming sever
84. o events in memory shows There are currently no events in memory 000005 O 8 O O 0EE 6 You can return to idle text at any time by pressing Exit button Walk Test CMD 4 4 Description Use this function to test keypads detection devices and sounders both interior and exterior to be certain they function properly You can review untested points at your keypad to help pinpoint any problems You cannot arm your system while in the walk test mode and no alarm reports are sent to your security company unless a 24 hour point is activated such as fire or panic A Walk Test Start Report might be programmed to be sent to your security company Upon initiation the walk test tests the burglary bell pattern on the bell output and ring the keypad burglary bell for 2 sec The AC is disabled for 4 minutes in order to test the system s battery power If the battery cannot maintain the system for the 4 minute period the keypad appears to power off If your keypads are programmed to be supervised the main alarm panel piezo intermittently during this 4 minute period If this happens contact your security company At the end of the 4 minute period AC is returned to the system and the control panel restores To test individual detection devices simply activate sensors and open protected doors and windows one at a time As each detection device is faulted the keypad emits a brief tone and the display indicates for
85. ons are also available Please consult your security company for services available in your area Your system makes repeated attempts to send reports to your security company In the event your security system fails to communicate the keypad sounds a Trouble Tone and shows Comm Fail Route Grp1 where the Route Group can be 1 2 3 or 4 AREA 1 WAREHOUSE Comm Fail Route Grpl Silence Help Menu Ga A GG KEEB O Ue E E QU ELI Notify your security company of the communications failure If your system uses telephone lines as its means of communication and telephone service is interrupted your security system cannot send reports to your security company unless it has an alternate means of transmitting them 14 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Il System Commands Table 2 Keypad Commands Part Il System Commands FE Kemadcommands Lo Some of these functions might not be COMMAND Function sid available In your system Please consult Master Arm your security company to determine which commands have been made available to you Master Arm Instant E Perimeter Instant If you attempt to enter a function that is not available or ifthe function is available in the system but your passcode is not authorized to perform the function then No Authority shows on the keypad Perimeter Delay Silence Trouble Sounder and Clear Trouble Display
86. or is not active in scope or user will not have access level authority Door is on timed door sequence Strike and shunt are latched active held open Strike and shunt are deactivated secured There is a problem with the door Call your security company Door is locked and ready for a command 3 Enter the number of the door you wish to cycle then press the ENTER button This door is cycled and the display changes to reflect the new status of the doors For example if you wanted to cycle Door 3 press 3 then press the ENTER button 39 D1265 Owner s Manual Part Ill Advanced Commands E The display changes to show that all the doors are at a normal state except for Door 3 which is cycled The display will return to the door number when the cycle command is complete 12C456 7 8 5 Enter another door number to cycle or press the Exit button to leave this function Unlock Door 1 IE you wish to unlock an access door to allow free access press the Unlock Door button The display reads Unlock Door 1 2 3 4 5 6 7 8 if all door are at a normal state and are available 12345678 If a door is not at a normal state the number of the door would be replaced with a symbol indicated in Table 3 Enter the number of the door you wish to unlock then press the ENTER button This door is unlocked and the display changes to reflect the new status of the doors o For example if you wanted to un
87. or other detection device Check the display after testing each point For interior points walking past the device once is sufficient If any point will not test correctly contact your security company for service During the Walk Test you might want to refer to the points that remain untested by pressing the View untested pts button view untestec The display shows pts untested Press the Point information button to see information about specific points that have not yet been tested The display changes to show the information for that point Move through this list by pressing the Next Point button Press the Exit button to return to the points remain to be tested before continuing the Service Walk Test When all points have been tested 0 points remain to be tested is shown Press the Exit button The display momentarily shows All points have been tested before returning to idle text Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Ill Advanced Commands Using Default Text This function allows the current state of the area for 3 sec before returning to idle text 1 Press the Default Text button to display the current state of the area 2 The current state of the area is shown for 3 sec before returning to idle text Keypad Setup Menu The Keypad Setup menu is accessible at anytime from any keypad menu To start the menu press and hold the 0 button for at
88. osch Security Systems Inc 9 10 FO1U169130 02 View Alarm Memory CMD 4 0 Description Your system stores events that occurred since the last time memory was cleared Use CMD 40 to view Alarm Memory Alarm Memory allows you or a service technician to review events after they are cleared from the keypad s display Alarm Silenced continues to scroll to remind you that events are stored in Event Memory Each time you turn the system on the Event Memory is erased and the Alarm Silenced message is cleared Using View Alarm Memory 1 Ensure the display shows disarmed idle text 2 Press the CMD button The display shows System Command System Command If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press Next button repeatedly When you reach the View Alarm Memory button press it View Alarm Memory 4 Your system shows event summary lines and point text in this order a fire alarm summary line b point text for each fire alarm event c alarm summary line d point text for each alarm event e fire trouble summary line f point text for each fire trouble event g trouble summary line h point text for each trouble event 5 Press Next to scroll through the events 23 D1265 Owner s Manual Part Il System Commands If there are no events to view There are currently n
89. ow arming to display for If there is a faulted point in more than one area and 3 sec before the prompt to arm the next the system is being armed the display prompts Check available area is shown Area 1 3 meaning there are faulted points in Areas 1 and 3 Try one of the following Turning on Multiple Areas with a Passcode You can use your personal passcode to turn on both perimeter and interior points in all areas where your e Clear faulted points close doors and or windows passcode has authority If there are areas already and return to step 1 turned on this function rearms those areas in addition e Bypass faulted points if your system and or to turning on all authorized areas that are currently off authority allows and return to step 1 1 Enter your passcode and press ENTER e Force arm if your system and or authority allows Arming 1 Refer to Turning On the System Arming With Doors All user or Windows Open on page 17 for more information authorized areas 00 06 Bosch Security Systems Inc 9 10 FO1U169130 02 63 D1265 Owner s Manual Part IV Multi Area Use Turn On the Entire System Without Delays You can use this function list function to turn on the entire system both perimeter and interior without delays You might use this function in all of the areas or some of the areas where your passcode has authority If there are areas already turned on this function rearms those areas in
90. ows Enter point number As soon as a digit button is pressed the display changes to Entering point number is the point number entered Entering point number 2 EX t o e a a fr If you know the point number you wish to bypass enter the number and press the ENTER button If you don t know the number of the point you wish to bypass you can view the list of devices that can be bypassed by pressing the Next button Continuously pressing Next scrolls through the available points that can be bypassed When the point text of the point you wish to bypass appears press the Bypass button Bypass P3 ENTRY DELAY is not bypassed indicates the point is not bypassed and the option is given to bypass it PH EMER BELA is not bypassed Previous Bypass Next E 844 GG KB One of the following messages shows P3 ENTRY DELAY is used here as an example 31 D1265 Owner s Manual Part Ill Advanced Commands P3 ENTRY DELAY is now bypassed indicates the point was successfully bypassed P3 ENTRY DELAY 15 now bypassed GR GA El eg Gi ETA a a O O O CD P3 ENTRY DELAY is already bypassed indicates that the point has already been bypassed P3 ENTRY DELAY 1s already bypassed e on ca ER EN ET O B O 005E P3 DELAY cannot be bypassed indicates the system is programmed not to allow that point to be bypassed P3 DELAY cannot be bypassed gua Invalid point Please try aga
91. panic and so on When the keypad s keypad lighting is on the keypad will not chime The buttons light for 20 sec whenever you press a button Use this function in residential systems to monitor entries or exits in your home In commercial systems it can serve as a door chime to alert you when a customer or delivery person enters your business Contact your security company to find out which points are watch points and whether or not your system automatically turns the Watch Mode on whenever you disarm 26 Entering Watch Mode 1 The display shows disarmed idle text 2 Press the CMD button The display shows System Command System Command ZS 00045 3 Press the 6 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press Next button repeatedly When you reach the Watch Mode button press it The display returns to show idle text Exiting Watch Mode 1 Ensure the display shows disarmed idle text 2 Press the CMD button The display shows System Command System Command 3 Press the 6 button Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Il System Commands If you prefer you might use the function Perimeter Partial CMD 8 list in place of Steps 2 and 3 to initiate Partially Turn On the Perimeter this function Desc
92. personnel monitor your security system 24 hours a day Your security system might be programmed to contact the central station during alarm conditions enabling central station personnel to dispatch the proper authorities A report your system can be programmed to send to the central station indicating that an area has been armed Opening and closing reports are commonly used by commercial accounts A list of functions programmed by your security company They can perform most keypad functions with only two or three button presses A programmed delay of system alarm response which allows you to enter an armed area through the correct point and disarm the area If you don t disarm before the delay time expires the system begins an alarm response which might include reports to the central station Exit Delay Faulted Point Force Arm Idle Text Master Arm Menu Opening Report Perimeter Arm Point Relay Trouble A programmed delay of system alarm response which allows you to exit after arming an area If you don t exit before the delay time expires entry delay begins You must disarm the system If you don t disarm before the delay time expires the system begins an alarm response which might include reports to the central station A point that is not normal a door or window is open To turn on arm the security system even though one or more points are faulted Force arming bypasses
93. play Print Log View Point Status C pm Extend Closing Terms Used in This Section Listed below are some of the terms you ll see throughout this section Each term is covered in greater detail later in this section and in Part II System Commands Account One or more areas reporting under a particular account number Area A group of detection devices connected to your security system Arm and Disarm To switch your burglar detection devices on and off When the burglar detection device is armed and is tripped an alarm might be set off When the burglar detection devices are disarmed the security system will not detect intruders Detection devices programmed as 24 Hour or Fire points are always on Authority Levels Levels of access authority assigned to passcodes Keypad Arming station used to operate your security system Keypad Scope Determines which areas a particular keypad can access Control Panel The main control unit which is locked in a steel enclosure It sends data to and receives inputs from the keypads Relays Optional dry contact outputs that respond to system events Skeds Functions programmed by your security company that occur at predetermined times 30 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Ill Advanced Commands User Passcodes Bypass a Point CMD 0 Description This command allows you to bypass points that you do not want included in the syste
94. r s Manual Part Ill Advanced Commands Contact your security company if you don t know what user numbers authority levels or areas are available Refer to the Appendix on page 67 for further information on adding passcodes Before you begin keep these points in mind 1 Do not try to add new users without knowing the available user numbers An already defined user number is overwritten when the new user is defined These are two or three digit numbers not to be confused with passcodes that identify users at your security company When choosing passcodes choose a new passcode three to six digits long If you choose a passcode with the same digit in consecutive order for example 33 in 334697 take care when entering it To avoid conflicting with other passcodes and duress codes your system will not let you change passcodes that are the same within plus or minus 2 of an existing passcode For example if 1234 were an existing code your system would not let you add or change your code to 1232 1233 1234 1235 or 1236 Choose an authority level for each area Not assigning the authority level for an area denies the passcode access to that area Ensure your keypad shows idle disarmed text Press the CMD button The display shows System Command System Command 000005 a O 000 Press the 5 button and then the 6 button If you prefer you might use the function list in place of Steps 2 and 3
95. r through the wrong door or fail to disarm before the entry delay time expires you cause an Enter passcode an If this happens silence the alarm by entering your then press ENTER Tr personal passcode and pressing ENTER and call your an d a a security company to let them know that it is not an EE Femme emergency situation 000046 2 The passcode is shown as asterisks when entered and advance from the right side of the display to the left until all passcode digits from a minimum of 3 to a maximum of six are entered If enabled by your security company there is a short period of time after the start of the alarm that a passcode entry aborts the transmission of the alarm report Alarm Aborted shows if this occurs Enter passcode Entering To Turn Your Security System Off Disarm 1 Enter your passcode and press ENTER EX1T 2 You must press the ENTER button within 5 sec B o E of entering your passcode or the passcode entry invalid 3 Press ENTER 3 The display returns to idle disarmed text Turning the System On Arming AREA 1 WAREHOUSE Al AREA IS OFF Your security system can be turned on armed in many different ways depending on the arming i CEET command used Arming Commands are those f Help D AID commands used to turn the system on The most basic Eu D ES E arming command is to arm the entire system There are several other arming commands to turn the system on These are describ
96. ready exists in your system Pressing the Next button exits from this function and returns the display to Add Change Level 54 Add Change Sub User ID For each user in the control panel with access control there can be up to four access cards one Master User assigned in the Card prompt and up to three sub users 1 Pressing the Sub User button allows you to add change a user s Sub User access card or credential 2 The display changes to Add Change Sub User IDs to add or change any of this user s sub user IDs Pressing the Yes button jumps to Step 3 Pressing the No button jumps to Add Change Passcode 3 The display changes to Select Sub User Do one of the following Press the Sub User 1 button to add or change sub user 1 Press the Sub User 2 button to add or change sub user 2 Press the Sub User 3 button to add or change sub user 3 Press the Exit button to return to the main Add Change User display 4 If adding or changing a sub user and a card reader is connected to your system the display changes to Add or Change Sub User 1 Present card to card reader now If the display changes to D9210 not ready contact your security company If 20 sec elapse without pressing a button the display returns to idle text Pressing the Exit button exits from this function and returns the display to the main Add Change User display 5 Ifthe card you are trying to add to the system already exis
97. red is valid the first event for that date appears Press the Exit button to exit this function and return to idle text If the date entered is invalid there are no events with that date in the log it shows the next latest event in the log Press the Exit button to exit this function and return to idle text The display shows one of two ways depending on if the date entered was for an event first in the log or not If the date was for the first event in the log it shows the next latest event in the log If the date was for an event not the first in the log the display is the same except the Previous button has been added Press the Exit button to exit this function and return to idle text Press the Next button to go to the next event in the log If there are no more events in the log End of Log appears Press the Previous button to go to the previous event in the log Press the Exit button to exit this function and return to idle text Using Print Log L Ze Press the Print Log button The display changes to Enter start date Press the Print all events button to print all events in the log Press the Exit button to exit this function and return to idle text The events are sent to a connected printer and display changes to Printing all events in history for 3 sec before returning to idle text Enter the start date in the form of mm dd For example to enter 12 21 as the start date press 1 2
98. ress It Perimeter Arm Part Bosch Security Systems Inc 9 10 FO1U169130 02 27 D1265 Owner s Manual Part Il System Commands 5 The display prompts the user to exit the area Special Alerts CMD 7 and CMD 9 and starts counting down seconds to arm the D n escription system Commands 7 and 9 can be programmed to respond to specific situations that might need immediate attention They might also be used to send a silent alarm to your security company without sounding an alarm signal on the premises Check with your security company for the options they offer Using CMD 7 Exit Now 15 seconds remaining is the number of sec remaining in the 1 Ensure your keypad shows idle text countdown l 2 Press the CMD button The display shows 6 When exit delay time expires and the system System Command turns on the display shows AREA 1 WAREHOUSE Perimeter On Partial 3 Press the 7 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Help Menu Press the Menu button to enter the 00906 function lst 7 To disarm enter your personal passcode and Press the Next button repeatedly press ENTER When you reach the User Command 7 button press it User Command 7 4 Your Command 7 special alert has been programmed to Q notify your alarm company ringa bell on your premises O display at your keypad Description
99. ress the No button to reject the name and return to Step 2 93 D1265 Owner s Manual Part Ill Advanced Commands Add Change Card 1 Pressing the Card button allows you to add change a user s access card or credential 2 The display changes to either one of the following depending on if an access card exists for the user User 123 Add Access Card for this user if no access card exists for that user User 123 Add Access Card for this user Yes 808 0 G KIB aaa O O CB Pressing the Yes button jumps to Step 3 Pressing the No button jumps to the Add Change Level screen User 123 Change this user s Access Card if an access card already exists for this user and you wish to change it In both cases 123 is used as an example Pressing the Yes button jumps to Step 3 Pressing the No button jumps to Add Change Level 3 Ifa card reader is connected to your system the display changes to Present card to card reader now If the display changes to D9210 not ready contact your security company Pressing the Exit button exits from this function and returns the display to idle text 4 Ifthe card you are trying to add to the system already exists an error tone sounds and the display changes to Card already exists Please try again Then the display returns to Present card to card reader now 5 Ifthe card is accepted the display changes to either Card added or Card changed if the card al
100. ription Press the Menu button to enter the ae This function is used to turn on the perimeter of your function list building while selected portions of the perimeter Press the Next button repeatedly remain turned off Perimeter points that are not secure faulted when this function is entered are automatically bypassed and are not included in the system This function will not turn on the interior of your building Entry exit delays are provided with this arming command 4 The display briefly shows Watch Mode is now Use this function in residential systems to turn on the off front of your house while the interior and the rear perimeter doors are left turned off giving you freedom of movement between the house and patio When you reach the Watch Mode button press it In commercial systems when you need access to the large overhead doors to receive deliveries using this function allows you to keep the rest of the building perimeter armed The display returns to show idle text Using Perimeter Partial 1 Ensure the display shows disarmed idle text 2 Press the CMD button The display shows System Command System Command 824 GG cs 00 906 3 Press the 6 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Perimeter Arm Part button p
101. s DSI f SecurityLevel E m M P P PD eDisarmlevi EY p jbp po po Functionkevi TD Keypad Function Authority Level Options Blank Disabled E Enabled Authority Level 15 can not be edited D9412GV3 D7412GV3 D9412GV2 D7412GV2 only Access Authority Level Options Security Level M Any Armed State P Perimeter Armed D Disarmed Blank No Access I Disarm to Perimeter Instant D Disarm All Blank No Disarm Rights Function Level Function Level M Any Armed State D Disarmed state C Any Armed state Blank Function disabled 68 Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Appendix User Passcode Worksheet User 000 to 038 User Area Authority H Passcode 1 2 3 4 5 6 7 8 000 KR EE TN JD ia Product Handler Note RADXUSRI is for Users 000 124 RADXUSR2 is for Users 125 249 Bosch Security Systems Inc 9 10 FO1U169130 02 Note Text shown in Times font ex 15 indicates sample text SERVICE PASSCODE USER 1 USER 2 USER 3 USER 4 USER 5 USER 6 USER 7 USER 8 USER 9 USER 10 USER 11 USER 12 USER 13 USER 14 USER 15 USER 16 USER 17 USER 18 USER 19 USER 20 USER 21 USER 22 USER 23 USER 24 USER 25 USER 26 USER 27 USER 28 USER 29 USER 30 USER 31 USER 32 USER 33 USER 34 USER 35 USER 36 USER 37 USER 38 SE E D Q Q lt
102. s e Print Log e View Log View Area Status Use this function when you need to know the status whether armed or disarmed of areas other than the one you re in 1 Ensure your keypad shows idle disarmed text 2 Press the Menu button to enter the function list 3 Press Next repeatedly until you reach the View Area Status button Press the button 4 The display changes to show on the top line the area name and the current status on the second line Pressing the Next button changes the display to the next area and remain for 20 sec or until the Next button is pressed for the next area If the time has elapsed the display returns to idle text Pressing the Previous button changes the display to the previous area 5 Press the Exit button to return to idle text Bosch Security Systems Inc 9 10 FO1U169130 02 View Point Status Use this function to identify the number or location of each point in an area and to show the current condition of any point you select 1 2 3 6 Ensure your keypad shows idle disarmed text Press the Menu button to enter the function list Press Next repeatedly until you reach the View Point Status button Press the button In this example Area 1 is the area and there are five points assigned to area 1 that can be viewed AREA 1 WAREHOUSE Area 1 5 Points Next Pt Exit Prev Pt o 8 8 0 8 E a A O O O aB Press the Next button to view the first point in the
103. s Not Ready to Arm AREA 1 WAREHOUSE NOT READY TO ARM View Points Cara Cm 1 4 Pressing the View Points button shows the specifics for any points that are faulted or bypassed Faulted points are shown first then bypassed points 5 The display changes to show the number of faulted points in the area AREA 1 WAREHOUSE has 1 faulted points Previous Si SH SEA o aa EI Ei 6 Press the Next button repeatedly to scroll through the point text for each faulted point 18 Once the last bypassed point is shown the display changes to show the button to either force arm the faulted points Force Arm or force arm the faulted bypassed points Force Bypass Arm AREA 1 WAREHOUSE Force Bypass Arm gt ene Previous Next 00000 Pressing the Next button at this screen aborts the arm command and return to viewing the faulted points Press the appropriate button to arm your system with the faulted bypassed points removed from Service Bosch Security Systems Inc 9 10 FO1U169130 02 Master Arm CMD 1 Description Use this function to turn on both the perimeter and interior of a single area indicated on the first line top of the keypad display When you turn the system on the display shows how many seconds of exit delay time you have to exit the protected area You should leave before exit delay time expires Leaving after exit delay has expired causes
104. scroll from oldest to newest Special System Trouble Display These displays appear on all keypads in the system Refer to Standard Displays on page 86 for a description of each system trouble display Pressing CMD 4 or the Silence button silences a system trouble tone but the System Trouble display will not clear until the faulted condition is corrected A system trouble display begins by sounding a trouble tone and then 3 sec later the specific System Trouble Display is shown such as Service AC Fail Some systems might be programmed to not initiate a trouble tone during these conditions Events Cleared from the Keypad Are Not Lost If you clear the alarms and troubles from the display you can still view all the events that occurred since the last time the system was armed by using CMD 40 View Alarm Memory Bosch Security Systems Inc 9 10 FO1U169130 02 Entry Delay Tone and Display When you enter an armed system through a point programmed for entry delay the keypad emits a repeating warble tone and displays a warning that the area is in entry delay This display alternates with one notifying you that a passcode entry is needed to turn off your security system If you fail to turn off the security system before the entry delay time expires it will sound the burglary tone and might also send an alarm report to your security company If enabled by your security company there is a short period of time after th
105. shows System Command System Command 0000895 a 3 Press the 5 button and then the 8 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Fire Walk Test button press It D1265 Owner s Manual Part Ill Advanced Commands 4 When the display shows points remain to be tested you can begin is the number of points Test each point by first activating the detection device to fault the point 6 points remain togbeatested View untested pts EN EY E ES El KEEB a a a a Oc If you know the point number you can enter it by pressing its number button and then the ENTER button The display changes to show the point that was entered If the point is invalid the message Invalid Point or This is not a valid walk point appears 5 As you fault each point your keypad shows the point text for 60 sec and ring the fire sounders for 2 sec This verifies that the detection device is working properly Your system automatically resets smoke detectors e When a resettable point such as a smoke detector is faulted the display shows Sensors resetting please wait for 5 sec During this time power is removed from smoke power relays Sensors resetting Please Wait 0000052 O o O O O CE e Fault
106. stem trouble displays shown below contact your security company to determine whether repairs are needed The Silence button is only shown if a trouble tone is present Press the Silence button to silence the following trouble conditions Call for Service Call your security company Your security system might have failed Your Alarm Company is replaced with the name of your security company Call for Service Contact us at Your Alarm Company 0000005 Service Battery Low Indicates the security system s battery is low or temporarily draining faster than the system can charge it If this display remains or appears frequently call your security company for service AREA 1 WAREHOUSE Service Battery Low Silence JE He Menu 09009045 Service AC Failure Indicates that AC power to the security system is interrupted Check the plug in transformer and circuit breaker Entering CMD 4 silences the trouble buzz The display clears when AC power returns AREA 1 WAREHOUSE Service AC Failure Silence E aa O O O CE Bosch Security Systems Inc 9 10 F01U169130 02 Serv Battery Missing Indicates the security system s battery is disconnected or shorted AREA 1 WAREHOUSE Serv Battery Missing Silence ae Menu eeedeco O do 0 o aD Service Communication Fail Your security system makes repeated attempts to communicate with the security company In the event your security s
107. t want a particular command included in a given authority level leave it blank Passcode Worksheet If you are having trouble understanding the concept of authority levels try this simple exercise Refer to the column titled E P in the User Interface section starting on page 67 Notice that your security technician has marked some of the cells in this column with the letter E others the letter P while others are left blank An E indicates that this function is enabled for all authority levels A P indicates that the function is passcode protected Look across the same row and notice that some of the cells in the authority level area have the letter E For each authority level in which an E appears this function is enabled with a passcode required A blank cell in the E P column means that this function is unavailable for any authority level Under the heading Authority Level you ll refer to columns 1 14 representing the fourteen authority levels Now look at the column labeled 1 Following down this column you ll refer to that some cells are blank while some contain the letter E which stands for enabled Wherever there is an E it means that that function is available to users with an authority level of 1 The passcode worksheet presents the information discussed previously onto one page and also includes the user s ID number assigned passcode and his or her name
108. t Please try again indicates that the entered point doesn t exist and the display returns to allow another point to be entered Invalid point Please try again 33 D1265 Owner s Manual Part Ill Advanced Commands No additional points indicates that there are no more points that can be bypassed No additional points 04108003 If an unbypassed point is entered an error tone will sound and a warning will be displayed P9 1s not bypassed edera The display returns to idle text 7 Ifyou are attempting to unbypass a 24 Hour or Fire Point that is still faulted the keypad shows Cannot unbypass 24hr faulted points cannot unbypass 24hr faulted points 828 GG EB a 0 O 006 34 Send Report CMD 4 1 or 4 2 Description This function tests the communication link between your security system and your security company lt is an important part of maintaining a high level of security for your property Two types of test reports can be sent The first type of report is a simple test report Command 41 The second type of report is a status report Command 42 This status report indicates the current condition of your system Using Send Report 1 Always call your security company before sending a test report 2 Ensure the display shows disarmed idle text 3 Press the CMD button The display shows System Command System Command 000006 4 Press the 4 button then t
109. t until all passcode digits are entered Press the ENTER button If the passcode matches the previously enter passcode the display changes to Passcode Added or Passcode Changed if user exists Pressing the Next button advances to the Add Change Level if the control panel does not have access control or Add Change Access Card if the control panel has access control Bosch Security Systems Inc 9 10 FO1U169130 02 If a duplicate passcode is entered the keypad momentarily reads Passcode is already in use Please try again Passcode 15 already in use Please try again SO 600 Ga If the passcode does not match the keypad emits an error tone and shows Passcode not changed Passcode not changed S O 000 4 Pressing the Next button advances to the Add Change Level if the control panel does not have access control or Add Change Access Card if the control panel has access control The display changes to User 3 Change this user s passcode User 3 Change this user s passcode Yes A ene GES Press the Yes button to change the passcode Press the No button not to change the passcode and skip ahead to Add Change Level if the control panel does not have access control otherwise if the control panel has access control the Add Change Card appears next You are prompted for the user s passcode As soon as a number is pressed Entering appears on the third line next to the aster
110. telephone line to which your control panel is connected Typical remote programming functions include changing personal passcodes changing entry exit delays resetting the system clock calendar and adding deleting system arming commands Your security company might ask you to follow the steps below to begin a remote programming session The time it takes to program the control panel is dependent on the number of changes made to the program You ll notice that two sets of procedures are presented The one you use depends upon whether your system has a pre programmed telephone number in its memory a My system does not have the RPS phone or the RPS network configured For systems without a phone number 1 Ensure the display shows disarmed idle text 2 Call this phone number This number is designated for the RPS You must make the call using the telephone located at 3 Identify yourself and your premises account number name address etc and advise the operator of the services you wish to have performed When the operator instructs you proceed to Steps 4 through 6 4 Press the CMD button The display shows System Command System Command 000046 Press the 4 button then the 3 button Advance the menu if necessary and select the Allow Answer option 35 D1265 Owner s Manual Part Ill Advanced Commands If you prefer you might use the function list in place of Steps 2 and 3 to initiate this f
111. ter Passcode and ENTER key to silence display will not be cleared To remove this display the FIRE ALARM fire point s must be returned to normal SMOKE DETECTOR If you have not cleared the Alarm Silenced display Enter Passcode and and wish to review cleared events use CMD 40 eier e to silence EN El EN ca di E 040001 Silencing Fire Alarms Entering a personal passcode with the proper authority level silences a fire alarm and disarms the system if it was armed Alarm Silenced em Clear DI TREN mm dea The system now shows Alarm Silenced and then the number of points in alarm FIRE ALARMS and then the area text appears AREA 1 NAME TEXT followed by the custom text of all the points in alarm for example SMOKE DETECTOR in the order of occurrence If there is more than one point causing an alarm the display shows each point for 3 sec before showing the next one When the last alarm is shown the next display is the first alarm Your system might be programmed so that you cannot silence some fire alarms until the fire event clears The Alarm Silenced message continues to alternate with idle text as a reminder that it is still possible to view the text of the points in alarm by using the View Alarm Memory function refer to View Alarm Memory CMD 4 0 on page 23 for more information To clear the event memory and remove the Alarm Silenced message from the display press the Cle
112. the faulted points The security system shows idle text at keypads when it is not performing a user requested function Idle text shows the arming status of the system To turn on arm both interior points and perimeter points A list of functions you execute from a keypad A report your system can be programmed to send to the central station indicating that an area has been disarmed Opening and closing reports are commonly used by commercial accounts An arming command that arms only the perimeter points A detection device or group of devices connected to your security system Points display individually at the keypad with custom text The text can describe a single door motion sensor smoke detector or an area such as UPSTAIRS or GARAGE Your system might have relays programmed to provide control of devices such as premises lighting or entry gates Your security company programs relays for automatic control and or control from your keypad A service condition that needs to be corrected such as a broken wire 89 D1265 Owner s Manual Appendix Maintenance and Service This security system requires very little maintenance however you should test the system weekly to ensure it is working properly A test schedule and maintenance program can be arranged If you notice a change in operation during normal use or testing call for service as soon as possible Do not attempt to repair the control panel
113. the new time using a 12 hour HH MM format For example if the desired time is 8 00 press 8 0 0 Press the ENTER button If the time is a valid time the keypad display changes to show the new time with a selection of AM or PM Press the AM button to select AM Press the PM button to select PM The display shows the Sked with the new time Press the Exit button to return to idle text Bosch Security Systems Inc 9 10 FO1U169130 02 D1265 Owner s Manual Part Ill Advanced Commands Table 4 Sked Table Excepton Time Day of Week Holiday SKED 1 SKED 2 SKED 3 SKED 4 SKED 5 SKED 6 SKED 7 SKED 8 SKED 9 SKED 10 SKED 11 SKED 12 SKED 13 SKED 14 SKED 15 SKED 16 SKED 17 SKED 18 SKED 19 SKED 20 SKED 21 SKED 22 SKED 23 SKED 24 SKED 25 SKED 26 SKED 27 SKED 28 SKED 29 SKED 30 SKED 31 SKED 32 SKED 33 SKED 34 SKED 35 SKED 36 SKED 37 SKED 38 SKED 39 SKED 40 Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SMTWTFS SM
114. this user authorized in Area 1 Press the Yes button to add change this user s authority level in Area 1 Press the No button if the user isn t authorized in Area 1 and proceed to display user s authorization in Area 2 Press the Exit button to exit from this menu and return to the Level changed display If the user is authorized in Area 1 the display changes to the User s current authority level 15 for Area 1 for example User s current authority level 15 Bas Enter d 00000 To change the Authority Level enter a new authority level from 1 to 15 if desired and press the ENTER button Before determining the Authority Level for a user please consult your security company to assist you in selecting the correct authority level Press the Exit button to exit from this menu and return to the Level changed display Repeat Step 2 for each area through Area 8 The display changes to User 3 Change this user s Auth Level Press the Yes button to add change this user s authority level in Area 1 Press the No button to advance to Add Change Passcode if the control panel does not have access control or to Change Sub User ID if the control panel has access control Press the Exit button to exit from this menu and return to the Level changed display refer to Step 6 If the user is authorized in Area 1 the display changes to User s current authority level 14 for Area 1 14 is used as an examp
115. ts an error tone sounds and the display changes to Card already exists Please try again If 20 sec elapse without pressing a button returns the display to idle text Pressing the Exit button exits from this function and returns the display to the main Add Change User display Press the Exit button to exit from this function and return the display to idle text Bosch Security Systems Inc 9 10 FO1U169130 02 6 Ifthe card is accepted the display changes to either Card added or Card changed if the card already exists in your system Pressing the Exit button exits from this function and returns the display to the main Add Change User display Pressing the Next button exits from this function and returns the display to Add Change Passcode depending on if a passcode already exists for the user Default Text CMD 5 7 This function allows the current state of the area for 3 sec before returning to idle text 1 Ensure your keypad shows idle disarmed text 2 Press the CMD button The display shows System Command System Command D1265 Owner s Manual Part Ill Advanced Commands Fire Test CMD 5 8 Use this function to test fire points and other 24 hour points to be certain they function properly You can review both the tested and untested points at your keypad to help pinpoint any problems Upon initiation the fire test tests the fire bell pattern on the bell output and ring the keypad f
116. unction Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Remote Program button press It Remote Program Press ENTER The display shows RPS connecting RPS connecting 00500052 000090 The security system now allows RPS to connect over the phone line or over the network to the control panel At the conclusion of the programming session your system sends a report to the security company and then returns your telephone to normal service and your display to idle text For systems with a phone number configured 36 a My system uses a phone number for Remote Programming Ensure your keypad shows idle disarmed text Press the CMD button The display shows System Command System Command o a 8 0 a a aa a O DEE Press the 4 button then the 3 button If you prefer you might use the function list in place of Steps 2 and 3 to initiate this function Press the Menu button to enter the function list Press the Next button repeatedly When you reach the Remote Program button press It Remote Program Press ENTER Select RPS via Phone The display shows RPS connecting RPS connecting 000005 O o O O O CR 6 The security system now calls the telephone number specified for the remote programming session 7 At the conclusion of the programming session your system sends a report to the security company and t
117. ystem fails to communicate the keypad buzzes and shows Comm Fail Route Grp1 Route Group number can be from 1 to 4 AREA 1 WAREHOUSE Comm Fail Route Grpl Silence oe Menu a a e e O E Notify your security company of the communication trouble Service Keypad Indicates that a keypad other than the one displaying the message is in a trouble condition Notify your security company AREA 1 WAREHOUSE Service Keypad emm silence Help Menu Service Phone Line 1 or 2 Indicates telephone line trouble Call your phone company from another phone to report telephone trouble This message might not appear in some systems AREA 1 WAREHOUSE Service Ph Line 1 silence 87 D1265 Owner s Manual Appendix Service Printer Printer number could also be 18 or 19 Indicates that a local printer if installed at your premises is in a trouble condition Check to be sure the printer is powered on the paper is correctly is inserted and the printer is selected Contact your security company if you have questions or the display doesn t clear You system might not include a local printer AREA 1 WAREHOUSE Service Printer Silence oe ga Menu ya E 000005 Service D9210 Indicates that one of the D9210 Access Control Modules possible of 8 total connected to the control panel has encountered a problem Contact your security company AREA 1 WAREHOUSE Service D9210 4 Silence DO

Download Pdf Manuals

image

Related Search

Related Contents

    Cobalt 2 User Manual  O2 Graph User Manual  Lincoln Electric IM916 User's Manual  Acco Quartet 8' x 4'    Kanibal II - Kortel Design  

Copyright © All rights reserved.
Failed to retrieve file