Home
Bosch Appliances 4000 Home Security System User Manual
Contents
1. Louis Missouri 63114 2029 USA Ph 314 426 2700 Fax 314 426 1337 CODE 3 est une marque d pos e d Public Safety Equipment inc R vision 0 07 04 Num ro de la pi ce 11195 De Livre D Instruction 2004 Public Safety Equipment Inc imprim aux Etats Unis 20
2. de l abus ou de l utilisation et ou des accidents peu communs n est pas couvert par cette garantie Le code 3 inc sera nullement responsable d autres dommages comprenant des dommages cons cutifs indirects ou sp ciaux si la perte est due la n gligence ou l infraction de la garantie CODER 3 MARQUES D INC AUCUNE AUTRE GARANTIE EXPRES OU IMPLICITE COMPRENANT SANS LIMITATION DES GARANTIES DE FORME PHYSIQUE OU VALEUR MARCHANDE EN CE QUI CONCERNE CE PRODUIT RETOURS DE PRODUIT Gi un produit doit tre retourn pour la r paration ou le remplacement svp entrer en contact avec notre usine pour obtenir un nombre de retour d autorisation de marchandises nombre de RGA avant toi bateau le produit pour coder 3 inc crire le nombre de RGA clairement sur le paquet pr s de l tiquette d envoi Etre s r tu les mat riaux d emballage suffisants d utilisation pour viter d endommager le produit tant retourn tandis qu en transit Coder3 r servations d inc la droite de r parer ou remplacer sa discr tion Le code 3 inc n assume aucune responsabilit ou responsabilit pour des d penses encourues pour le d placementet oula r installation des produits exigeantle service et ou la r paration ni pour l empaquetage manipuler et embarquer ni pour la manutention des produits revenir l exp diteur apr s que le service ait t rendu CODE 3 Inc 10986 N Warson Road St
3. i Externe HAUT FUSIBLE PARLEUR 100W Moteur Commutateur DOl CT Le Sch ma 5 Diagramme De cablage 17 DEPANNAGE PROBLEME CAUSE PROBABLE REMEDE AUCUN RENDEMENT A AUCUN V OU TERRE A VERIFIER Les FILS DE SIRENE B HAUT PARLEUR COURT CIRCUITE De PUISSANCE OU FILS De HAUT PARLEUR SIRENE DANS MODE COURANT DE B VERIFIER Les RACCORDEMENTS De PROTECTION D EXCEDENT HAUT PARLEUR COUPS DE FUSIBLE A Les FILS De PUISSANCE A VERIFIER La D AMPLIFICATEUR ONT RENVERSE POLARITE La POLARITE AUCUN RENDEMENT A CIRCUIT NON RELIE OUVERT A VERIFIER Le DEORATEUR D ORATEUR DANS Le CABLAGE De CABLAGE De HAUT TONALITES ENTENDU HAUT PARLEUR PARLEUR L INT RIEUR B HAUT PARLEURS D FECTUEUX B REMPLACER AMP RE MODULE SPEAKER S TONALIT S DE SIR NE A BASSE TENSION A A EXAMINER Le CABLAGE VOLUME AUSSI AMPLIFICATEUR De SIR NE POUR DECELER Les LOW GARBLED B RESISTANCE ELEVEE DANS Le CONNEXIONS HAUT PARLEUR De WIRING MAUVAISES Le SYSTEME DEFECTIVE De REMPLISSAGE VEHICULE De CONTROLE B VERIFIER SPEAKER S WIRING REPLACE SPEAKER S TAUX ELEVE DE ECHEC D ORATEUR A HAUTE TENSION A la SIRENE B HAUT PARLEUR De 58 WATTS RELI 58 WATTS NON LAISS S A V RIFIER Le SYST ME De REMPLISSAGE De V HICULE B EMPLOYER Le HAUT PARLEURCORRECT P A VOLUME BAS O A MICROPHONE D FECTUEUX A REMPLACER Le AUCUN P A LA B MICROPHONE PAS MICROPHONE COMMAN
4. a Return Goods Authorization Number RGA number before you ship the productto Code 3 Inc Write the RGA number clearly on the package near the mailing label Be sure you use sufficient packing materials to avoid damage to the product being returned while in transit Code 3 Inc reserves the right to repair or replace atits discretion Code 3 Inc assumes no responsibility or liability for expenses incurred for the removal and or reinstallation of products requiring service and or repair nor for the packaging handling and shipping nor for the handling of products return to sender after the service has been rendered CODE 3 Inc 10986 N Warson Road St Louis Missouri 63114 2029 USA Ph 314 426 2700 Fax 314 426 1337 Code 3 is a registered trademark of Public Safety Equipment Inc 1 0 Revision 0 07 04 Instruction Book Part No 11195 2004 CODE 3 Inc Printed in USA INSTALLATION et OPERATION MANUEL SIRENES DE SERIES 4000 ACODE 3 PUBLIC SAFETY EQUIPMENT INC cor SIRENES AVERTISSEMENT Les sir nes produisent les bruits forts qui peuvent endommager l audition e Protection d audition d usage en examinant e Utiliser la sir ne seulement pour la r ponse de secours e Enrouler les fen tres quand la sir ne fonctionne e viter l exposition au bruit de sir ne en dehors de du v hicule Lire tous les instructions et avertissements avant d installer et employer IM PO RTANT Srn
5. e d fectueux sous l utilisation normale et dans la garantie N importe quelle tentative d entretenir une unit dans la garantie par n importe qui autre qu un technicien autoris par usine sans consentement crit expr s par l usine annulera la garantie Des unit s hors de la garantie peuvent tre r par es lusine pour une somme nominale sur un taux forfaitaire ou des pi ces et base de travail Entrer en contact avec l usine pour des d tails et des instructions de retour Le du code 3 n est pas responsable d aucun frais fortuit li la r paration ou au remplacement d une unit moins qu ait autrement express ment t d accord sur dans l criture 16 r Amplificateur De Sir ne Vue Eclat e No DeR f rence Description Num ro de la pi ce Quantit 1 Fusible 10A Mini ATO T03066 1 2 5 SMS casserole Hd Phil de 6 x T06313 18 3 vis de machine de 375 de 4 40 x casserole Hd Phil T06937 2 4 6rondelle plate nylon noir T10151 20 5 Cl ture Aluminium Expuls 711145 1 6 Garniture 711148 1 7 Hamas de fil microphone T11191 1 8 Plaqued extr mit 711150 1 9 Assy de Carte model 4012 T11186 1 model 4013 711187 1 model 4024 T11188 1 model 4025 711189 1 10 Plaque d extr mit avec l Assembl e de connecteur 1 Aucune PA 711201 Avec la PA 711202 NUIT MICROPHONE d ACTIVEZ Models 401 402 odels 4013 amp 4025 only TA
6. la contrainte psychologique et physiologique provoqu e par la situation de secours Le syst me de sir ne devrait tre install d une telle fa on quant A Ne pas r duire l ex cution acoustique du syst me B limite autant que pratique le niveau de bruit dans la cabine passagers du v hicule C endroit les commandes dans l extension commode de l op rateur de sorte qu il puisse actionner le syst me sans contact d oeil perdant avec la chauss e Les dispositifs d avertissement de secours exigent souvent des tensions et ou des courants lectriques lev s Correctement prot ger et faire attention autour des raccordements lectriques de phase Fondre ou court circuiter des raccordements lectriques peut causer des courant lev ce qui peut des blessures graves et ou endommage le v hicule y compris le mettre en feu L INSTALLATION APPROPRI E COMBIN E AVEC LA FORMATION D OP RATEUR DANS L UTILISATION APPROPRI E DES DISPOSITIFS D AVERTISSEMENT DE SECOURS EST ESSENTIELLE POUR ASSURER LA SURETE DU PERSONNEL DE SECOURS ET DU PUBLIC Dispositifs Standard Les 4000 s ries de E escroquent des sir nes se composent de l amplificateur distance mont de sir ne sont fonctionn es par des r gulations des march s d un utilisateur Les mod les sont comme suit 4012 12V Aucune Adresse Publique 4013 12V Avec L Adresse Publique 12 4024 24V Aucune Adresse Publique 4025 24V Avec L Adresse Publique In
7. DE DE COMPLETEMENT BRANCHE B BRANCHER Le VOLUME ETANT PLACE C MICROPHONE INCORRECT MICROPHONE AU MAXIMUM SOLIDEMENT C UTILISER SEULEMENT Le MICROPHONE Du CODE 3 La SIRENE A Les DISJONCTEURS De A SEREFERER A la FONCTIONNE VEHICULE NON EVALUES SECTION De CORRECTEMENT MAIS CORRECTEMENT ET CARACTERISTIQUES S ARR TE TOUT EN SURCHAUFFENT OUNE EMPLOYERUnBRISEUR COURANT DEMARRE FONCTIONNENT PAS VALU 1 25x ALORS COURIR CORRECTEMENT L AMP RAGE Du ENCORE APR S COURANT PR VU De QUELQUES MINUTES CHARGE 18 NOTES GARANTIE Les dispositifs du secours de Code 3 sont examin s et ont trouv pour tre op rationnels a l heure de la fabrication S ils sont install s et actionn s selon les recommandations du fabricant les garanties du code 3 de l inc toutes les pi ces et les composants except les lampes une p riode de 1 an moins qu autrement exprim partir de la date de l achatou dela livraison celui quiest plus tardif Des unit s d montr es pour tre d fectueuses au cours dela p riode de garantie seront r par es ou remplac es au centre commercial d usine a aucun co t L utilisation de la lampe ou de toute autre charge lectrique d une puissance en watts plus haut qu install ou recommand par l usine ou l utilisation de la protection inad quate ou insatisfaisante de c blage ou de circuit fait devenir cette garantie vide L chec ou la destruction du produit r sultant
8. IN WIRING CHECK VEHICLE DEFFECTIVE SPEAKER CHARGING SYSTEM B CHECK SPEAKER WIRING REPLACE SPEAKER HIGH RATE OF A HIGH VOLTAGE TO SIREN A CHECK VEHICLE SPEAKER FAILURE B 58 WATT SPEAKER CONNECTED CHARGING SYSTEM 58 WATT SPEAKER NOT ALLOWED B USE CORRECT SPEAKER PA VOLUME LOW OR A DEFECTIVE MICROPHONE A REPLACE NO PA WITH VOLUME B MICROPHONE NOT COMPLETELY MICROPHONE CONTROL SET TO MAX PLUGGEDIN B PLUG MICROPHONE C INCORRECT MICROPHONE INSECURELY C USE ONLY CODE 3 MICROPHONE SIREN RUNS A VEHICLE CIRCUIT BREAKERS A REFER TO PROPERLY BUT SHUTS NOT RATED PROPERLY AND ARE SPECIFICATIONS DOWN WHILE OVERHEATING OR ARE NOT SECTION USE A RUNNING THEN STARTS RUNNING AGAIN AFTER A FEW MINUTES FUNCTIONING PROPERLY BREAKER RATED AT 1 25x THE AMPERAGE OF THE EXPECTED LOAD CURRENT 4 A ka e e N A J ZA Siren Amplifier Exploded View Ref No Description Part No Qty 1 Fuse 10A Mini ATO T03066 1 2 6x 5 SMS Pan Hd Phil T06313 18 3 4 40 x 375 Machine Screw Pan Hd Phil T06937 2 4 6 Flat washer Nylon Black T10151 20 5 Enclosure Extruded Aluminum T11145 1 6 Gasket 711148 1 7 Wireharness microphone 711191 1 8 End Plate T11150 1 9 PCB Assy 1 Model 4012 12V No PA T11186 Model 4013 12V with PA T11187 Model 4024 24V No PA T11188 Model 4025 24V with PA T11187 10 End Plate w Connector Assembly 1 No PA T11201 With PA T11202 NUIT MICR
9. INSTALLATION amp OPERATION MANUAL 4000 SERIES SIRENS RE CODE 3 PUBLIC SAFETY EQUIPMENT INC cu SIRENS WARNING Sirens produce loud sounds that may damage hearing e Wear hearing protection when testing e Use siren only for emergency response e Roll up windows when siren is operating e Avoid exposure to the siren sound outside of vehicle 7 Read all instructions and warnings before installing and using IMPORTANT SV This manual must be delivered to the end user of this equipment Introduction The 4000 series of electronic sirens have been designed to meet the needs of all emergency vehicles This series of sirens incorporates many popular features of the Code 28 siren line with microprocessor based circuitry and MOSFET technology AN WARNING SIREN PRODUCTS Sirens are an integral part of an effective audio visual emergency warning system However sirens are only short range secondary warning devices The use of a siren does not insure that all drivers can or will observe or react to an emergency warning signal particularly at long distances or when either vehicle is traveling at a high rate of speed Sirens should only be used in a combination with effective warning lights and never relied upon as a sole warning signal Never take the right of way for granted It is your responsibility to be sure you can proceed safely before entering an intersec tion driving against traffic or responding at a high rate o
10. OPHONE Models 4013 amp 4025 only ACTIVEZ n External 100W FUSE SPEAKER Ignition Switch IO Figure 5 Wiring Diagram 9 WARRANTY Code 3 Inc s emergency devices are tested and found to be operational at the time of manufacture Provided they are installed and operated in accordance with manufacturer s recommendations Code 3 Inc guarantees all parts and components except the lamps to a period of 1 year unless otherwise expressed from the date of purchase or delivery whichever is later Units demonstrated to be defective within the warranty period will be repaired or replaced at the factory service center at no cost Use of lamp or other electrical load of a wattage higher than installed or recommended by the factory or use of inappropriate or inadequate wiring or circuit protection causes this warranty to become void Failure or destruction of the product resulting from abuse or unusual use and or accidents is not covered by this warranty Code 3 Inc shall in no way be liable for other damages including consequential indirect or special damages whether loss is due to negligence or breach of warranty CODE 3 INC MAKES NO OTHER EXPRESS OR IMPLIED WARRANTY INCLUDING WITHOUT LIMITATION WARRANTIES OF FITNESS OR MERCHANTABILITY WITH RE SPECT TO THIS PRODUCT PRODUCT RETURNS Ifa product must be returned for repair or replacement please contact our factory to obtain
11. ction will override the siren function when the microphone Push to Talk button is pressed Models 4013 and 4025 only Automatic Short Circuit Protection The siren will sense a short circuit on the speaker terminals and automatically go to standby until the fault is removed Once the fault is removed the siren will return to normal operation Noise Canceling Microphone A Plug in noise canceling microphone Models 4013 and 4025 only is provided for easy service or replacement Unpacking amp Pre installation After unpacking your 4000 Series Siren carefully inspect the unit and associated parts for any damage that may have occurred in transit Report any damage to the carrier immediately Installation amp Mounting Figure 1 Light Bar Mounting The 4000 Series of Sirens is designed to be mounted inside a light bar or inside the vehicle Do not mount the siren inside the engine compartment Mounting hardware is supplied see Fig 2 for mounting the amplifier inside the light bar NOTE Setups and adjustments will be made in subsequent steps that may require access to the siren Plan the installation and wiring accordingly Amplifier Connections Siren Amplifier Connector Refer to the Wiring Diagram in Figure 5 page 10 for detailed information about the amplifier connections As a standard feature the 4000 Series of Siren are equipped with a combination plug in terminal block connector To terminate the wires strip approximat
12. d 110hm 100W Spkr 4012 et 4013 4 6 amp res de 27 6V avec la charge d 110hm 100W Spkr 4024 et 4025 Courant d op ration nuit 0 8 amp re de 13 8V avec la charge d 110hm 100W Spkr 4012 et 4013 0 4 amp re de 27 6V avec la charge d 11ohm 100W Spkr 4024 et 4025 Temp rature de fonctionnement C 35 au C 85 14 Courant De secours 25 mA si directement a la batterie 0 mA w Ignition AU LOIN si par le commutateur d allumage de v hicule recommand Tension produite approximativement 70V de cr te cr te jour cr te 4 2V la cr te nuit Poids 1 08 kilogramme avec des supports Section Audio Models 4013 Et 4025 R ponse sonore le DB 3 se dirige vers le bas 500 3000 hertz 1000 hertz 0 r f rences de DB D formation audio 10 ou moins au dessous de la coupure ENTRETIEN Votre Code 3 sir ne de 4000 s ries a t con u pour fournir le service sans ennuis En cas de difficult voir le d pannage En outre v rifier court circuit ou ouvrir les fils La cause primaire des courts circuits s est av r e des fils passer par des murs l preuve du feu des toits etc Si plus loin la difficult persiste entrer en contact avec l usine pour le conseil de d pannage ou les instructions de retour Le Code 3 maintient des pi ces compl tes inventorient et service le service l usine et r pareront ou remplaceront l option de lusine n importe quelle unit av r
13. ely 1 4 of insulation from the end of each wire and insert it in the appropriate hole in the terminal block Tighten the setscrew and proceed to the next connection Should you ever have to remove the unit loosen the security screws and pull the terminal block straight out It will unplug from the siren leaving the wiring in place Terminal Block Connections V Connect to the negative terminal of the battery This supplies ground earth to the siren Use 14 gauge wire V Connect to a positive 12 volt DC source 24 volts for Models 4024 and 4025 It is recommended that the user protect this wire with a 10 Amp fuse or circuit breaker located at the power source 5 Amp fuse for Models 4024 and 4025 Use 14 gauge wire NUIT Connect to a switch which will supply ground earth when ON Use 14 16 gauge wire ACTIVEZ Connect to a switch will supply ground earth when ON Use 14 16 gauge wire HP1 Speaker Connect to the wire from 100W 11 ohm speaker terminal 1 HP2 Connect to the wire from one 100W 11 ohm speaker terminal 2 SETUP AND ADJUSTMENT P A Volume Adjustment Public Address volume is set by the sliding volume control located on the front of the microphone Set this control to give the desired PA Volume level The user may adjust this control at any time during use Tone Selection Referring to Figure 2 and Figure 3 and the Siren Tone Chart Figure 4 set the 16 position rotary switch SW1 located ins
14. f speed The effectiveness of this warning device is highly dependent upon correct mounting and wiring Read and follow the manufacturer s instructions before installing ng this device The vehicle operator should check the equipment daily to insure that all features of the device operate correctly To be effective sirens must produce high sound levels that potentially can inflict hearing damage Installers should be warned to wear hearing protection clear bystanders from the area and not to operate the siren indoors during testing Vehicle operators and occupants should assess their exposure to siren noise and determine what steps such as consultation with professionals or use of hearing protection should be implemented to protect their hearing This equipment is intended for use by authorized personnel only It is the user s responsibility to understand and obey all laws regarding emergency warning devices The user should check all applicable city state and federal laws and regulations Code 3 Inc assumes no liability for any loss resulting from the use of this warning device Proper installation is vital to the performance of the siren and the safe operation of the emergency vehicle It is important to recognize that the operator of the emergency vehicle is under psychological and physiological stress caused by the emergency situation The siren system should be installed in such a manner as to A Not reduce the acoustical performance of t
15. ge Output approx Weight Audio Section Audio Response Audio Distortion 10 to 16 VDC negative ground earth Models 4012 and 4013 20 to 30 VDC negative ground earth Models 4024 and 4025 9 2 Amps 13 8V with 11 ohm load 100W Spkr Models 4012 and 4013 4 6 Amps 27 6V with 11 ohm load 100W Spkr Models 4024 and 4025 0 8 Amps 13 8V with 11 ohm load 100W Spkr Models 4012 and 4013 0 4 Amps 27 6V with 11 ohm load 100W Spkr Models 4024 and 4025 35 C to 85 C 25 ma If direct to battery 0 ma w Ignition OFF if through vehicle ignition switch 70V peak to peak Day 4 2V peak to peak Night 1 08 Kg with mounting brackets 3 dB down points 500 to 3000 Hz 1000 Hz 0 dB Reference 10 or less below clipping MAINTENANCE Your Code 3 4000 series siren has been designed to provide trouble free service In case of difficulty see Troubleshooting Also check for shorted or open wires The primary cause of short circuits has been found to be wires passing through firewalls roofs etc If further difficulty persists contact the factory for troubleshooting advice or return instructions Code 3 maintains a complete parts inventory and service facility at the factory and will repair or replace at the factory s option any unit found to be defective under normal use and in warranty Any attempt to service a unit in warranty by anyone other than a factory authorized technician without express written conse
16. guide optique ou l int rieur d un v hicule Ne pas monter la sir ne l int rieur du compartiment r acteur Le mat riel de support est fourni voir la fig 2 pour monter l amplificateur l int rieur du guide optique NOTE Les installations et les ajustements seront faits dans les tapes suivantes d pendant du mod le et des options achet s qui peuvent exiger l acc s au secteur arri re de l unit Projeter l installation et le c blage encons quence solidement attach s aux l ments de v hicule de la force suffisante pour r sister aux forces appliqu es au dispositif La facilit d emploi et la convenance l op rateur devrait WARNING tre la consid ration principale en montant la sir ne et les commandes Ajuster langle de support pour permettre la visibilit maximum d op rateur Ne pas monter la module de commande dans un endroit qui obstruera la vue de conducteurs Monter l agrafe de microphone dans un endroit commode pour permettre l op rateur l acc s facile Des dispositifs devraient tre mont s seulement dans les endroits qui se conforment leur code d identification de SAE comme d crit dans SAE J1849 standard Par exemple l lectronique con ue pour le support int rieur ne devrait pas tre underhood etc plac s Des commandes devraient tre plac es dans l extension commode du conducteur ou si pr vu pour l op ration de deux personnes le conducteur et ou le passager Dans des quel
17. he system B Limit as much as practical the noise level in the passenger compartment of the vehicle C Place the controls within convenient reach of the operator so that he can operate the system without losing eye contact with the roadway Emergency warning devices often require high electrical voltages and or currents Properly protect and use caution around live electrical connections Grounding or shorting of electrical connections can cause high current arcing which can cause personal injury and or severe vehicle damage including fire PROPER INSTALLATION COMBINED WITH OPERATOR TRAINING IN THE PROPER USE OF EMERGENCY WARNING DEVICES IS ESSENTIAL TO INSURE THE SAFETY OF EMERGENCY PERSONNEL AND THE PUBLIC Standard Features The 4000 series of E CON sirens consist of remotely mounted siren amplifier is operated by a user supplied controls The models are as follows 4012 12V No Public Address 4013 12V With Public Address 4024 24V No Public Address 4025 24V With Public Address Instant On Applying Ground to the ACTIVEZ terminal will cause the siren to operate in Day power mode When either the Police or Emergency Medical Siren Tones are selected SW1 set to 0 or 2 applying Ground to both the ACTIVEZ and the NUIT terminal will switch to Night power mode Pressing the microphone Push to Talk PTT button on models 4013 and 4025 will activate the Public Address function Instant Public Address The Public Address fun
18. ide the siren to the number which corresponds to the desired tone Unless otherwise specified at the time of order the default setting is 0 Police securely fastened to vehicle elements of sufficient strength to withstand the forces applied to the device Ease of operation and convenience to the operator should be the prime WARNING consideration when mounting the siren and controls Adjust the mounting angle to allow maximum operator visibility Do not mount the Control Head Module in a location that will obstruct the drivers view Mount the microphone clip in a convenient location to allow the operator easy access Devices should be mounted only in locations that conform to their All devices should be mounted in accordance with the manufacturer s instructions and SAE identification code as described in SAE Standard J1849 For example electronics designed for interior mounting should not be placed underhood etc Controls should be placed within convenient reach of the driver or if intended for two person operation the driver and or passenger In some vehicles multiple control switches and or using methods such as horn ring transfer which utilizes the vehicle horn switch to toggle between siren tones may be necessary for convenient operation from two positions Specifications Siren Section Input Voltage Operating Current Day Operating Current Night Operating Temperature Standby Current recommended Volta
19. itu la source d nergie fusible de 5 amp res pour models 4024 et 4025 Fil de mesure de l utilisation 14 NUIT relier un commutateur qui assurera la terre la terre quand DESSUS Fil de mesure de l utilisation 14 16 ACTIVEZ relier un commutateur qui assurera la terre la terre quand DESSUS Fil de mesure de l utilisation 14 16 HP1 haut parleur se relient au fil 11 ohms de la borne 1 du haut parleur 100W HP2 relier au fil d une 11 ohms borne 2 du haut parleur 100W INSTALLATION ET AJUSTEMENT P A Ajustement de volume le volume d adresse publique est plac par la commande de volume coulissante situ e sur l avant du microphone Placer cette commande pour donner le niveau d sir de volume de PA L utilisateur peut ajuster cette commande tout moment pendant l utilisation Choix de tonalit se rapportant au sch ma 2 et le sch ma 3 et le diagramme de tonalit de sir ne le sch ma 4 a plac le commutateur rotatoire SW1 de 16 positions situ l int rieur de la sir ne au nombre qui correspond la tonalit d sir e Sauf indication contraire a l heure d ordre l arrangement de d faut est 0 police Caract ristiques Section De Sir ne Tension d entr e 10 16 volts continu la terre n gative la terre models 4012 et 4013 20 30 volts continu la terre n gative la terre models 4024 et 4025 Courant d op ration jour 9 2 amp res de 13 8V avec la charge
20. na E manuel doit tre livr Putilisateur de cet quipement 11 Introduction Sir nes lectroniques de s ries 4000 ont t con ues pour satisfaire les besoins de tous les v hicules de secours Cette s rie de sir nes incorpore beaucoup de dispositifs populaires de la ligne de sir ne du code 3 avec les circuits bas s sur microprocesseur et la technologie de transistor MOSFET AVERTISSEMENT PRODUITS DE SIRENE Les sir nes sont une partie int grale d un syst me d avertissement de secours efficace d audio visual Cependant les sir nes sont que des dispositifs d avertissement secondaires de gamme courte L utilisation d une sir ne n assure pas que tous les conducteurs peuvent ou observeront ou r agiront un signal d alarme de secours en particulier de longues distances ou quand l un ou l autre v hicule voyage un rapport de vitesse lev On devrait seulement tre utilis dans une combinaison avec les voyants d alarme efficaces et ne jamais compter au moment des sir nes comme signal d alarme unique Ne jamais prendre la droite de la mani re pour accord Il est de votre responsabilit d tre s r que tu peus proc der sans risque avant d entrer dans une intersection conduire contre le trafic ou r pondre un rapport de vitesse lev L efficacit de ce dispositif d avertissement d pend fortement du support et du c blage corrects Lire et suivre les instructions du fabricant avan
21. nt by the factory will void the warranty Units out of warranty can be repaired at the factory for a nominal charge on either a flat rate or parts and labor basis Contact the factory for details and return instructions Code 3 is not liable for any incidental charges related to the repair or replacement of a unit unless otherwise expressly agreed to in writing 7 6 SHEETMETAL SCREW S 8 REQ D Figure 2 Disassembly R4 H Lem R26 Lu M2 5 8 1 o yy e s l RI SW Figure 3 16 Position Rotary Switch Tone Select Chart swt __Discription O Co Poe O O O O oOo y O fGendarmene O O C Pomes SSCS CMD OS SSCOCCC dS l is OOS O O E Figure 4 Tone Select Chart TROUBLESHOOTING Refer to wiring diagram on page 10 PROBLEM PROBABLE CAUSE REMEDY NO SIREN OUTPUT A NO V OR GROUND A CHECK POWER B SHORTED SPEAKER OR WIRES SPEAKER WIRES sIREN IN OVER B CHECK SPEAKER CURRENT PROTECTION MODE CONNECTIONS FUSE BLOWS A AMPLIFIER POWER WIRES A CHECK POLARITY REVERSED POLARITY NO OUTPUT FROM A SPEAKER NOT CONNECTED A CHECK SPEAKER SPEAKER TONES OPEN CIRCUIT IN SPEAKER WIRING WIRING HEARD INSIDE B DEFECTIVE SPEAKER B REPLACE SPEAKER AMPLIFIER MODULE SIREN TONES VOLUME A LOW VOLTAGE TO SIREN A CHECK WIRING FOR TOO LOW GARBLED AMPLIFIER BAD CONNECTIONS B HIGH RESISTANCE
22. ques v hicules commutateurs de commande multiples et ou m thodes en utilisant telles que le transfert d anneau de klaxon qui utilise le commutateur de klaxon de v hicule pour basculer entre les tonalit s de sir ne peut tre n cessaire pour l op ration commode de deux positions Tous les dispositifs devraient tre mont s selon les instructions du fabricant et tre Raccordements D Amplificateur Connecteur d amplificateur de sir ne se r f rer au diagramme de c blage sur le sch ma 5 page 10 pour des informations d taill es sur les raccordements d amplificateur Comme dispositif standard les sir nes de s rie 4000 sont quip es d une borne embrochable block connector de combinaison Pour terminer les fils d pouiller approximativement 1 4 de l isolation de l extr mit de chaque fil et l ins rer dans le trou appropri dans le TB Serrer la vis de r glage et proc der au prochain raccordement Si tu doit jamais enlever l unit desserrer les vis de s curit et tirer le TB directement dehors II d branchera de la sir ne laissant le c blage en place Raccordements De TB V Relier la borne n gative de la batterie Ceci fournit la terre la terre la sir ne Fil de mesure de l utilisation 14 V relier un positif la source de C C de 12 volts 24 volts pour models 4024 et 4025 On recommande que l utilisateur prot gent ce fil avec un fusible un le disjoncteur de 10 amp res s
23. stantan Sur appliquer la terre la borne d ACTIVEZ fera fonctionner la sir ne en mode de puissance de jour Quand la police ou des tonalit s m dicales de sir ne de secours est choisie SW1 placer 0 ou a 2 appliquant la terre a l ACTIVEZ et la borne de NUIT commuteront au mode de puissance de nuit En serrant le microphone Pousser a Parler le bouton PTTS sur les models 4013 et 4025 activeront la fonction d adresse publique Adresse publique instantan e la fonction d adresse publique d passera la fonction de sir ne quand le microphone Pousser a Parlent le bouton est serr models 4013 et 4025 seulement Protection automatique de court circuit la sir ne sentira un court circuit sur les bornes de haut parleur et ira automatiquement la ressource jusqu a ce que le d faut soit enlev Une fois que le d faut est enlev la sir ne reviendra l op ration normale Microphone d annulation de bruit un microphone d annulation de bruit embrochable models 4013 et 4025 seulement est donn pour le service ou le remplacement facile D ballage Et Pr installation Apr s d ballage de votre sir ne de 4000 s ries inspecter soigneusement l unit et les pi ces associ es pour d celer n importe quels dommages qui ont pu tre produits en transit Rapporter n importe quels dommages au porteurimm diatement Installation Et Montage Les 4000 s ries de sir nes sont con ues pour tre mont es l int rieur d un
24. t d installer ou l aide de ce dispositif L op rateur de v hicule devrait v rifier le journal d quipement pour s assurer que tous les dispositifs du dispositif fonctionnent correctement Pour tre efficaces les sir nes doivent produire les niveaux sonores lev s qui potentiellement peuventinfliger des dommages d audition Des installateurs devraient tre avertis de porter la protection d audition spectateurs clairs du secteur et de ne pas actionner la sir ne l int rieur pendant l essai Les op rateurs et les occupants de v hicule devraient valuer leur exposition au bruit de sir ne et d terminer quelles tapes telles que la consulta tion avec des professionnels ou l utilisation de la protection d audition devraient tre mises en application pour prot ger leur audition Cet quipement est pr vu l usage du personnel autoris seulement Il est de la responsabilit de l utilisateur de comprendre et ob ir toutes les lois concernant les dispositifs d avertissement de secours L utilisateur devrait v rifier tous les ville applicable tat et lois et r glements f d raux Le code 3 inc n assume aucune responsabilit pour n importe quelle perte r sultant de l utilisation de ce dispositif d avertissement L installation appropri e est essentielle l ex cution de la sir ne et de l exploitation s re du v hicule de secours Il est important d identifier que l op rateur du v hicule de secours est sous