1. FIG 12 A ADJUSTMENTS Always disconnect the appliance from the electricity main before making any adjustments All seals must be replaced by the technician at the end of any adjustments or regulations Our burners do not require primary air adjustment 8 TAPS Our taps are suitable for all gas they are male conical type Reduced rate adjustment Switch on the burner and turn the relative knob to the Reduced rate position small flame fig 1 Remove knob M fig 13 of the tap which is simply pressed on to its rod Insert a small screwdriver D into hole C fig 13 and turn the throttle screw to the right or left until the burner flame has been adequately regulated to the Reduced rate position Check that the flame does not go out when the knob is sharply switched from the Full on to the Reduced rate position It is understood that only burners operating with Natural gas should be subjected to the above mentioned adjustments The screw must be fully locked when the burners operate with Liquid gas CONVERSIONS 9 U LPG TO NATURAL GAS CONVERSION PROCEDURE Appliance models Gas crystal glass hotplate models BCGC74 4 Burners BCGC52 2 Burners 1 Remove each burner cap and burner skirt 2 Remove the U LPG main injector with a 7 mm VF tube spanner and replace with the appropriate size Natural Gas main injector for each
2. BCGC52 CRYSTAL GLASS COOKTOP BLANCO sane Performance Tirst We ask that you carefully read the instructions within this booklet to enable you to abtain quality results from the outset The appliance must be installed only by an authorised person in compliance with the instructions provided The manufacturer declines all responsability for improper installation which may harm persons and animals and damage property The appliance must be used for the purpose for which it was expressly designed Any other use eg heating rooms is considered to be improper and consequently dangerous The manufacturer declines all responsability for damage resulting from improper and irresponsible use The manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors The designs in the figures are purely indicative The manufacturer also reserves the right to make any modifications to the products as may be considered necessary useful or in the interests of the user without jeopardizing the main functional and safety features on the products themselves If your cooktop requires service please contact your local customer service centre or your nearest Blanco agent listed at the back of this booklet COD 01019GG 18 07 2006 DESCRIPTION OF THE HOT PLATES Natural U LPG 1 Ultra rapid gas burner of 11 9 MJ 11 9 MJ 2 Semirapid gas burner of 6 3 MJ 6 3 MJ 3 Auxiliary gas bur
3. USE INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR BUILT IN HOT PLATES Dear Customer Thank you for purchasing a Blanco Cooktop Before we continue telling you about this cooktop we cordially invite you to become part of the Blanco family by subscribing to ongoing information and invitations Please visit our website where you can subscribe and request such things as invitations to future cooking classes and gourmet recipes Go to www meaappliances com au and fill in the subscription details You will find that the clean lines and modern look of your Blanco Cooktop blends perfectly with your kitchen d cor It is easy to use and performs to a high standard Blanco also makes a range of products that will enhance your kitchen such as ovens rangehoods dishwashers microwaves sinks and taps There are models to complement your new Blanco Cooktop Of course we make every effort to ensure that our products meet all your requirements and our Customer Relations department is at your disposal to answer your questions and to listen to all your suggestions see back cover of manual Please complete the warranty section of this manual and keep your receipt as proof of purchase Retain all documents relating to the purchase of this products Blanco is committed to providing increasingly efficient products that are easy to use respect the environment and are attractive and reliable BLANCO BLANCO Performance First MODELS BCGC74
4. as this will concentrate and deflect heat onto the hotplate Do not use large pots or heavy weights which can Symbol 3 bend the pan support or deflect flame onto the hotplate Air inlet minimum section 100 cm CLEANING IMPORTANT Always disconnect the appliance from the gas and electricity mains before carrying out any cleaning operation 2 HOT PLATE Periodically wash the hot plate the cast iron pan support the enamelled burner caps C and the burner heads M see fig 6 with lukewarm soapy water Following this all parts should be thoroughly rinsed and dried Never wash them while they are still warm and never use abrasive powders Do not allow vinegar coffee milk salted water lemon or tomato juice from remaining in contact with the enamelled surfaces for long periods of time WARNINGS Comply with the following instructions before remounting the parts Check that burner head slots M fig 6 have not become clogged by foreign bodies Check that enamelled burner cap C fig 6 have correctly positioned on the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Do not use steam jet
5. NSIONS Overall Dimensions 680 x 500 mm FIG 8 INSTALLATION 5 LOCATION AND VENTILATION Ventilation must be in accordance with AS5601 AG 601 Gas Installations In general the appliance should have adequate ventilation for complete combustion of gas proper flueing and to maintain temperature of immediate surroundings within sate limits The wall and bench surfaces must be capable of susiaining temperatures of 75 TC All laminates fixing adhesive and surfacing materials should be certified suitable for this temperature 6 GAS CONNECTION This gas connection is male 1 2 BSP and is situated at the rear of the appliance 415 mm from the right hand side and 55 mm from the rear of the cooktop A The hotplate can be connected with rigid pipe as specified in AS5601 table 3 1 B If installing with a hose assembly install with a hose assembly that complies with AS NZS 1869 AGA Approved 10mm ID class B or D no more than 1 2m long and in accordance with AS5601 Ensure that the hose does not contact the hot surfaces of the hotplate oven dishwasher or any other appliance that may be installed undemeath or next to the hotplate The hose should not be subjected to abrasion kinking or permanent deformation and should be able to be inspected along its entire length with the cooktop in the installed position Unions compatible with the hose fittings must be used and all connections tested for gas leaks The ga
6. burner The following injector sizes are required for Natural Gas Burner Main injector Wok 1 55 mm Semi Rapid 1 12 mm Auxiliary 0 85 mm 3 Shut off gas supply to the appliance 4 Disconnect gas inlet pipe from the U LPG Gas test point inlet fitting 5 Remove the U LPG test point inlet fitting from the appliance 6 Fit the Natural Gas Regulator supplied in the conversion kit 7 Connect the gas supply to the Regulator 8 Check for gas leaks Do not use a naked flame to check for gas leaks 9 Adjust the gas pressure to 1 00 kPa 10 Remove the control knob with a thin shaft blade screwdriver down the centre of each gas valve shaft screw the by pass injector anti clockwise Test the appliance on both high and low flame for each burner If the burner fails to remain alight or the flame is not stable on the simmer setting adjust the by pass screw until flame is stable 11 If not already removed remove the Only for use with U LPG label adhered to the bottom panel near the gas connection 10 10 NATURAL GAS TO UNIVERSAL LPG CONVERSION PROCEDURE Appliance models Gas crystal glass hotplate models BCGC74 4 Burners BCGC52 2 Burners 1 Remove each burner cap and burner skirt 2 Remove the Natural Gas main injector with a 7 mm VF tube spanner and replace with the appropriate size U LPG main injector for each burner The following injector sizes are required for U LPG Burner Main injector Wok 0 95 mm S
7. emi Rapid 0 70 mm Auxiliary 0 53 mm 3 Remove the control knob with a thin shaft blade screwdriver down the centre of each gas valve shaft screw the by pass injector fully clockwise 4 Shut off gas supply to the appliance 5 Disconnect gas inlet pipe from the Natural Gas Regulator 6 Remove the Natural Gas Regulator from the appliance 7 Fit the U LPG test point inlet fitting supplied in the conversion kit 8 Connect the gas supply to the inlet fitting 9 Check for gas leaks Do not use a naked flame to check for gas leaks 10 Adjust the gas pressure to 2 75 kPa 11 Test the appliance on both high and low flame for each burner and check the gas pressure If the burner fails to remain alight or the flame is not stable on the simmer setting adjust the by pass screw until flame is stable 12 If not already removed remove the Only for use with Natural Gas label adhered to the bottom panel near the gas connection Op CONVERSIONS BURNER ARRANGEMENT ON THE HOT PLATE G BURNERS DESCRIPTION ULTRA RAPID U LPG NATURAL TABLE NORMAL PRESSURE kPa INJECTOR DIAMETER NOMINAL HEAT INPUT MJ h BY PASS 1 100 mm MAX 1 100 mm SEMIRAPID U LPG NATURAL AUXILIARY U LPG NATURAL 11 SERVICING WARNING Always disconnect the appliance from the electricity and gas mains before proceeding with any serv
8. ice and Spare Parts Advantage Appliances Telephone 03 9874 4222 Facsimile 03 9874 6917 QUEENSLAND State Office and Showroom 148 Robinson Road East Geebung QLD 4034 Telephone 07 3259 2555 Facsimile 07 3265 6933 Endeavour Appliances Telephone Facsimile 07 3872 7444 07 3852 2465 Platinum Appliance Service Telephone 07 3862 1154 Facsimile 07 3862 1114 Roshad Gold Coast Telephone Facsimile 07 5535 7044 07 5535 7407 14 SOUTH AUSTRALIA amp NORTHERN TERRITORY Agent and Sales Office S C Lighting amp Electrical Supplies 47 North Terrace Hackney SA 5069 Telephone 08 8362 4599 Facsimile 08 8362 4591 Service and Spare Parts Prestige Appliance Repair Centre Telephone 08 8352 2022 Facsimile 08 8352 3044 WESTERN AUSTRALIA Agent and sales Office Elite Appliance Marketing Pty Ltd P O Box 2387 Warwick 6024 Telephone 08 9201 0311 Facsimile 08 9201 0366 Service and Spare Parts Metropolitan Appliance Repairs Telephone 08 9330 1724 Facsimile 08 9317 1296 TASMANIA Agent and Sales Office Mark Pearce Agencies 23 Tranmere Road Howrah TAS 7018 Tel Fax 03 6247 9215 Service and Spare Parts Electrical Equipment Service Launceston Telephone 03 6339 3873 Facsimile 03 6339 4588 Baldocks Appliance Service Hobart Telephone 03 6234 5995 Facsimile 03 6234 8134 BLANCO CUSTOMER SERVICE 1300 739 033 Website www meaappliances com au Showrooms open six days a
9. icing operation Servicing should be carried out only by authorised personnel 11 COMPONENTS REPLACEMENT NOTE BEFORE ANY MAINTENANCE REQUIRING REPLACEMENT OF A COMPONENT IS UNDERTAKEN ENSURE THAT THE ELECTRICAL LEAD HAS BEEN ISOLATED AND REMOVED FROM THE POWER POINT To replace the components fit inside the hob it is first necessary to remove the hot palte itself from the cabinet to overturn it unscrew screws V and to remove part T fig 15 After having carried out the above listed operations the burners fig 16 taps fig 17 and electrical components can all be replaced fig 18 It is advisable to change seal D each time a tap is changed in order to ensure a perfect tightness Greasing the taps see fig 19 20 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions Remove the tap Clean the cone and its housing using a cloth soaked in diluent Lightly spread the cone with the relative grease Fit the cone back in place operate it several times and then remove it again Eliminate any excess grease and check that the gas ducts have not become clogged Fit all parts back in place complying with the demounting order in reverse The tight closure test must be done using a foamy liquid the flame use is forbidden To facilitate the servicing technician s task here is a chart with the types and sections of the poweri
10. into wich the appliance will be recessed see fig 7 Any adjoining wall surface situated within 200 mm from the edge of any hob burner must be a suitable non combustible material for a height of 150 mm for the entire length of the hob Any combustible construction above the hotplate must be at least 600 mm above the construction above the top of the burner and no construction shall be within 450 mm above the top of the burner A minimum depth of 60 mm from the top of the work surface must be provided for this appliance 4 FIXING THE HOT PLATE The hot plate has a special seal which prevents liquid from infiltrating into the cabinet Strictly comply with the following instructions in order to correctly apply this seal Take off all the movable parts of the hob Cut the seal in 4 parts of the necessary length to positioning it on the 4 edges of the crystal Overturn the hot plate and correctly position seal E fig 8 under the edge of the hob itself so that the outer side of the seal perfectly matches the outer perimetral edge of the hob The ends of the strips must fit together without overlapping Evenly and securely fix the seal to the hob pressing it in place with the fingers Remove the strip of protective paper from the seal Fit the hot plate into the hole in the cabinet and lock it in place with the relative fixing screws F of the fixing hooks G see fig 9 COMPLY WITH THE DIME
11. ly lead The point of attachment for this lead is located at the rear and on the underside of the appliance 380 mm from the right hand side The voltage and power consumption are detailed on the underside of the appliance Ensure that the appliance is correctly rated to the supply Connect appliance by way of a switched power point THE APPLIANCE MUST BE EARTHED Ensure that this power point is properly earthed Look at the connection wiring diagrams fig 12 or 12 A ELECTRIC WIRING DIAGRAM IGNITION GENERATOR 230 240 V a Data Label The Data Label is located on the underside of the hotplate A duplicate Data Label is supplied to adhere in an accessible area next to the hotplate This hotplate is suitable for Natural Gas and Universal LPG ensure that the available gas supply matches the Data Label b Before Leaving Check that there are no gas leaks but do not use a naked flame to detect gas leaks Ignite all burners to ensure correct operation of gas valves burners ignition and if fitted flame failure valves Turn gas taps to low flame position and observe stability of the flame When satisfied with the hotplate please instruct the user on the correct method of operation In case the appliance falls to operate correctly after all checks have been carried out refer to the authorised service provider in your area HOTPLATES WITH 4 BURNERS ELECTRIC WIRING DIAGRAM 230 240 V
12. ner of 3 6 MJ 3 6 MJ 4 Cast iron trivet 1 burner 5 6 7 Cast iron trivet 2 burner Cast iron trivet 3 burner Burner control knobs Attention this appliance has been manufactured for domestic use only and is for use by private persons USE 1 BURNERS A diagram is screen printed above each knob on the front panel This diagram indicates to which burner the knob in question corresponds After having opened the gas mains or gas bottle tap light the burners as described below Manual ignition Push and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position large flame fig 1 then place a lighted match near the burner Electrical ignition Push and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position large flame fig 1 then depress and release the ignition button Automatic electrical ignition Push and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position large flame fig 1 then depress the knob Lighting burners equipped with flame failure device The knobs of burners equipped with flame failure device must be turned in an anticlockwise direction until they reach the full on position large flame fig 1 and come to a stop Now depress the knob in question and repeat the previously indicated operation
13. ng cables and the ratings of the electrical components PIG 15 HG16 COAG FIG yA 12 SERVICING CABLE TYPES AND SECTIONS TYPE OF TYPE OF HOT PLATE CABLE SINGLE PHASE POWER SUPPLY Gas hot plate HO5 RR F ATTENTION Section 3 X 0 75 mm If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 21 and comply with the recommendations given in paragraph 8 TECHNICAL ASSISTANCE AND SPARE PARTS MEA BLANCO TECHNICAL ASSISTANCE AND SPARE PARTS NEW SOUTH WALES Head Office Sales amp Marketing Office 104 Vanessa Street Kingsgrove NSW 2208 Telephone 02 9503 2888 Facsimile 02 9503 2810 NSW Showroom 40 Ebley Street Bondi Junction NSW 2022 Telephone Facsimile 02 9386 1190 02 9386 1671 Agent and Sales Office Hi Performance Marketing 7 Coleman Street Mascot NSW 2020 Telephone Facsimile 02 88354937 02 90048739 Service and Spare Parts All General Whitegoods Service Telephone 02 8788 8666 Facsimile 02 9756 1091 AUSTRALIAN CAPITAL TERRITORY Service and Spare Parts Detlevs Appliance amp Electrical Care 1 88 Sheppard Street Hume ACT 2905 Telephone 02 6280 1033 Facsimile 02 6260 1035 VICTORIA State Office and Showroom 35 Centre Road Scoresby VIC 3179 Telephone Facsimile 03 8756 7888 03 8756 7907 Serv
14. s Keep the knob depressed for about 10 seconds once the burner has ignited Note you are advised not to try and light a burner if the flame divider Burner Cap is not correctly placed In the event of burner flames being accidentally extinguished turn off the burner control and do not attempt to re ignite the burner for at least 1 minute FIG 1 HOW TO USE THE BURNERS In order to achieve maximum efficiency with the least possible gas consumption Use adequate pans for each burner consult the following table and fig 2 When the pan comes to the boil set the knob to the reduced rate position small flame fig 1 Always place a lid on the pans Burners Power ratings Pan in cm Natural U LPG Ultra rapid 11 9MJ 11 9MJ 22 28 Semirapid 6 3 MJ 6 3 MJ 16 18 Auxiliary 3 6 MJ 3 6 MJ 10 14 WARNINGS Burners with flame failure device may only be ignited when the relative knob has been set to the Full on position large flame fig 1 Matches can be used to ignite the burners in a blackout Never leave the appliance unattended when the burners are being used Make sure there are no children in the near vicinity Particularly make sure that the pan handles are correctly positioned and keep a check on foods requiring oil and grease to cook since these products can easily catch fire Do not spray aerosols in the vicinity of this appliance while it is in operation This appliance is no
15. s for cleaning the cooktop PREVENTATIVE MAINTENANCE This cooktop should not require ongoing maintenance provided you ensure All spillages are cleaned up as soon as they occur Burners are kept clean Burner ports are free of debris food any anything else that may cause an obstruction Electrode and thermocouples are kept clean Burners are re assembled correctly Do not get water in the area where the injectors are located INSTALLATION TECHNICAL INFORMATION FOR THE INSTALLER This appliance shall be installed only by authorised personnel and in accordance with the manufacturer s installation instructions local gas fitting regulations municipal building codes water supply regulations electrical wiring regulations AS 5601 AG 601 Gas Installations and any other statutory regulations 3 INSTALLING THE HOT PLATE Check that the appliance is in a good condition after having removed the outer packaging and internal wrappings from around the various loose parts In case of doubt do not use the appliance and contact qualified personnel Never leave the packaging materials cardboard bags polystyrene foam nails etc within children s reach since they could become potential sources of danger The measurements of the opening made in the top of the modular cabinet and into which the hot plate will be installed are indicated in fig 7 Always comply with the measurements given for the hole
16. s supply connection for the hose assembly must be accessible Natural Gas Natural Gas installations require the connection of a gas regulator at the appliance This regulator is supplied with the appliance on purchase Assemble the regulator noting the gas flow direction and transition pieces supplied with the appliance in accordance with figure 10 The transition piece on the supply side of the regulator must be provided by the installer The appliance is factory set for Natural Gas The test point pressure should be adjusted to 1 00 kPa with the wok burner operating at maximum Liquified Petroleum Gas In a Universal LPG installation the gas regulation is made at the gas cylinder and regulation at the appliance is not required The supply pressure should be 2 75 kPa To connect supply to the appliance use transition pieces as shown in figure 11 These pieces are supplied with the appliance on purchase WARNING THE BURNER FLAME MUST BE ADJUSTED BY THE INSTALLER FAULTY INSTALLATION WILL NOT BE COVERED UNDER WARRANTY Gas connection for NATURAL GAS Gas inlet pipe Sesser f Gasket Brass conical adaptor Thread tight use suitable seal ___ Gas regulator Gas connection for U LPG GAS Gasket Brass conical adaptor Thread tight use suitable seal Test point adaptor INSTALLATION 7 ELECTRICAL CONNECTION The appliance is supplied with a 1800 mm long flexible supp
17. t to be installed in marine craft Where this appliance is installed in a caravan it shall not be used as a space heater Do not store or use flammable liquids or items in the vicinity of the hotplate FIG 2 USE Notes Use of a gas cooking appliance produces heat and moisture in the room in which it is installed The room must therefore be well ventilated by keeping the natural air vents clear fig 3 and by activating the mechanical aeration device rangehood or electric fan fig 4 and fig 5 Intensive and lengthy use of the appliance may require additional ventilation This can be achieved by opening a window or by increasing the power of the mechanical exhausting system if installed Star Trivet use star trivet whenever using a small pot Abnormal Operation Any of the following are considered to be abnormal operation and may require servicing Yellow tipping of the hob burner flame Sooting up of cooking utensils Burners not igniting properly Burners failing to remain alight Burners extinguished by cupboard doors Gas valves which are difficult to turn In case the appliance fails to operate correctly contact the authorised service provider in your area Do not place anything eg flame tamer asbestos mat between pan and pan support as serious damage to the appliance my result Symbol 1 Do not remove the pan support and enclose the Symbol 2 burner with a wok stand
18. week 16

Download Pdf Manuals

image

Related Search

Related Contents

iRobot Roomba serie 700  CB-01 Manuel d`instructions  創成電極工具を用いた微細放電加工* Study of Micro-EDM  Wiley The Technology Garden: Cultivating Sustainable IT-Business Alignment  Samsung VAC6313G User Manual  inspection, maintenance and recharge  Powermate PM0535001 Parts list  Original - Avanti Online  Kompernass KH 1207 User's Manual  APT10-4.5型ハイブリッド・プレッシャーポンプ取扱説明書  