Home
Axis Communications 233D Security Camera User Manual
Contents
1. Install two Duotec strips on the spacers Install the two remaining strips on the back of the escutcheon trim plate All other models round escutcheon Install two Duotec strips directly on the carrier plate Install the remaining two strips on the back of the escutcheon English All models Install the carrier plate and gasket With the carrier plate screws Press the escutcheon firmly over the carrier plate The strips of Duotec will interlock producing a very firm hold Install the handle Tighten the handle screw with a 3 mm Allen wrench The handle screw must engage the slot milled into the brass on the bottom of the cartridge Set the high temperature limit stop optional see page 11 Justify the handle Justify the handle Tools required Thermometer 3 mm Allen wrench Turn the valve on Place the thermometer in the water stream Turn the temperature control knob until the output water is 100 F Turn the water off Use a 3 mm Allen wrench to loosen the handle set screw Remove the handle from the valve 1 Hold the handle lever in one hand With the other hand turn the temperature control knob approximately J turn clockwise 2a Then without pressing inward on it turn it counter clockwise until it is positioned vertically and hits the safety stop 2b Install the handle 3 Tighten the screw English Set the high temperature limit stop opti
2. de sortie sur ThermoBalance haite utiliser la pomme de douche et les jets lil muraux simultan ment Notez que la sortie 1 est galement raccord e la pomme de douche Installation Attention Avant de commencer fermez l eau la valve principale Raccordez les conduites d alimentation de l eau chaude et de l eau froide la pi ce int rieure La conduite d alimentation de l eau chaude doit tre install e dans l orifice d arriv e pr vu pour l eau chaude et la conduite d eau froide doit tre install e dans l orifice d arriv e pr vu pour l eau froide S il s agit d une construction non r cente assurez vous que les conduites d alimen tation d eau froide et d eau chaude n ont pas t invers es Si les conduites ne sont pas raccord es dans les bons orifices la valve ne pourra fonction ner correctement Pour le bien de clart le i box n est pas montr e dans cette illustration Ne pas enlevez le i box Mod le 06628000 seulement Lors du rac cordement des arriv es d eau chaude et froide te nez la but e d arr t l aide d une cl pour qu elle ne bouge pas afin de pr venir tout d salignement ou rupture des l ments filet s scell s en usine Installez toutes les conduites de sortie Ne mettez de bouchon sur aucune des sorties Le robinet doit tre de niveau sur tous les plans Installez la pi ce int rieure de fa on ce que
3. d fectueuse Les filtres de la cartouche thermo statique sont obtures Ce probl me n est pas du a une d fectuoisite du produit les conduites d alimentation d eau chaude et d eau froide sont invers es Francais Solution Enlevez le joint Remplacez l l ment thermosta tique Serrez la vis de la poign e Ceci n est pas un probleme Remplacez l l ment thermosta tique R glez a nouveau la but e d eau chaude R glez la poign e Remplacez la cartouche thermo statique Remplacez la cartouche thermo statique Nettoyez les filtres Modifiez les raccordements 27 Replacement Parts 88500000 cartridge 2 retainer plate 88524000 3 sleeve 88520XX0 4 carrier plate 88518000 5 duotec spacers 88529000 6 duodec strips 96234000 7 carrier plate screw 88652000 8 cross handle 88608XX0 9 lever handle 88610XX0 10 scroll handle 88609XX0 11 Solaris handle 88530XX0 12 Stratos handle 88547XX0 13 Metro handle 88548XX0 14 Talis handle 88641XX0 15 Metris handle 88713XX0 16 Focus handle 88714XX0 28 17 oval escutcheon 88532XX0 18 round escutcheon 88522XX0 19 C escutcheon 88748XX0 G 20 thermostat cartidge 94282000 21 Allegro handle 88719XX0 22 Metro handle 88721XX0 XX color code 00 chrome 197 62 oil rub bronze 82 brushed nickel 83 polished nickel 92 rubbed bronze 93 polished brass included with Solaris oval escutcheon only Cleaning
4. e S il choisit la douche trois fonctions l utilisateur doit d cider AVANT L INSTALLATION quelles sont les deux qui fonctionneront simultan ment Ces deux fonctions doivent tre raccord es partir des sortie ll et lll De plus l utilisateur doit d cider laquelle des deux fonctions sera la premi re Si la poign e est tourn e depuis la position d arr t off la sortie ll viendra en premier Installation sugg r e syst mes trois fonctions Les installations suivantes sont les plus courantes avec ThermoBalance lll mais il existe d autres installations possibles La douchette est raccord e la sortie 1 elle ne peut fonctionner avec aucune autre fonction La pomme de douche est raccor d e la sortie 2 et les jets de corps la sortie 3 La pomme de douche et les jets de douche peuvent fonctionner individuellement ou simultan ment La pomme de douche vient en premier Dans cette installation baignoire dou che le bec de la baignoire est raccord sur la sortie 1 et ne peut fonctionner que s par ment La pomme de douche et la douchette raccord es aux sorties 2 et 3 peuvent fonctionner soit individuellement soit simultan ment La pomme de douche vient en premier Fran ais Raccordement sp cial syst me deux fonctions NO f N obturez aucune conduite Dans ce type d installation l utilisateur sou
5. la surface ext rieure du mur fini tombe entre les lignes minimum et maximum de la bo te d installation i box Vous vous assurez ainsi que la garniture s ajustera correctement La boite d installation doit demeurer sur la valve Installez le mat riau du mur jusqu la boite d ins tallation Une fois la garniture install e la boite d installation i box doit tre coup e presque galit du mur fini et scell e pour assurer une protection contre les dommages d eau Francais Miminum wall thickness hot chaud caliente We WARNING cold fria froid Maximum wall thickness Rincez les conduites d alimentation l aide du bouchon de rin age La boite d installation i box comprend un bovu chon de rin age permettant de rincer la conduite et de tester la pression avant que la cartouche et la garniture ne soient install es ll est recommand d effectuer un test de pression de la tuyauterie avant de fermer les murs Le bouchon de rin age permet l eau froide de circuler dans les conduites de sortie et Il et l eau chaude de circuler dans la conduite de sortie Il Fixez des embouts de raccordement pour tuyau souple et des tuyaux aux orifices de sortie Rincez les conduites durant au moins 5 minutes Servez vous des tuyaux pour diriger l eau dans un emplacement o le d versement ne causera aucun dommage Le bouchon de rin a
6. Recommendation for Hansgrohe Products Modern lavatory faucets kitchen faucets and showers consist of very different materials to comply with the needs of the market with regard to design and functionality To avoid damage and returns it is necessary to consider certain criteria when cleaning Cleaning Materials for Faucets and Showers Acids are a necessary ingredient of cleaning materials for removing lime however please pay attention to the follow ing points when cleaning faucets and showers e Only use cleaning materials which are explicitly intended for this type of application e Never use cleaning materials which contain hydrochloric formic phosphoric or acetic acid as they cause considerable damage e Never mix one cleaning material with another e Never use cleaning materials or appliances with an abrasive effect such as unsuitable cleaning powders sponge pads or micro fiber cloths Cleaning Instructions for Faucets and Showers Please follow the cleaning material manufacturer s instructions In addition pay attention to the following points e Clean the faucets and showers as and when required e Use the amount of cleaning product and the amount of time recommended by the manufacturer Do not leave the cleaner on the fixture longer than necessary e Regular cleaning can prevent calcification e When using spray cleaners spray first onto a soft cloth or sponge Never spray directly onto the faucet as drop lets can
7. any failure to comply before you can bring any action in court against us under the Magnuson Moss Warranty Act PRODUCT INSTRUCTIONS AND QUESTIONS Upon purchase or prior to installation please carefully inspect your Hansgrohe product for any damage or visible defect Prior to installing always carefully study the enclosed instructions on the proper installation and the care and maintenance of the product If you have questions at any time about the use installation or performance of your Hansgrohe product or this warranty please call or write to us or call us toll free at 800 334 0455 31 ansgrone Hansgrohe Inc e 1490 Bluegrass Lakes Parkway e Alpharetta GA 30004 Tel 770 360 9880 Fax 770 360 9887 www hansgrohe usa com US Installation Instructions Part No 90965101 06 Revised 07 2009
8. e dans le sens antihoraire pour envoyer l eau la sortie Ill Lorsque la poign e est entre la position Il et Ill l eau viendra des deux sorties ll est impossible de faire fonctionner les trois conduites de sortie en m me temps Pour que l eau soit plus chaude tournez le bouton de contr le de la temp rature dans le sens antihoraire Le contr le de temp rature s arr te lorsque l eau atteint 100 F c est l arr t de s ret Pour outrepasser l arr t de s ret appuyez sur le bouton de contr le de la temp rature et continuez le tourner dans le sens antihoraire Pour que l eau soit plus froide tournez le bou ton de contr le de la temp rature dans le sens horaire Important le r glage du bouton de contr le de la temp rature ne revient pas automatiquement sous 100 F une fois l eau ferm e 25 Fran ais Entretien Nettoyage des tamis de filtre ATTENTION Avant de commencer fermez l eau soit la vanne principale soit aux but es d arr t le pan de manoeuvre Retirez la poign e et l cusson l aide d une cl molette saisissez le pan de manoeuvre sur le dispositif d arr t Tenez fermement le dispositif d arr t en place A l aide d une seconde cl molette ou d une cl doville longue de 17 mm d vissez la cartouche thermostatique et retirez la e ATTENTION Le dispositif d arr t pourrait tre endommag si vous ne le retenez pas fermement en pl
9. enter openings and gaps and cause damage e After cleaning rinse thoroughly with clean water to remove any cleaner residue Important Residues of liquid soaps shampoos and shower foams can also cause damage so rinse with clean water after using Please note if the surface is already damaged the effect of cleaning materials will cause further damage Components with damaged surfaces must be replaced or injury could result Damage caused by improper treatment is not covered under the warranty Recommandations pour le nettoyage des produits Hansgrohe Les robinetteries modernes de lavabo de cuisine et de douche utilisent des mat riaux tr s diff rents pour r pondre aux besoins du march en termes de conception et de fonctionnalit Certaines r gles de base doivent amp tre respect es lors du nettoyage de ces produits afin d viter de les endommager ou d avoir les retourner Produits de nettoyage pour robinetteries et douches Les acides sont une partie int grante n cessaire de tous les produits de d tartrage il faut cependant prendre les pr cautions suivantes lors du nettoyage des robinets et des douches e N utilisez que des produits articles de nettoyage con us sp cifiquement pour les articles de robinetterie et de douche e N utilisez jamais de produits articles de nettoyage contenant de l acide chlorhydrique formique phosphorique ou ac tique car ils pourraient causer des dommages consid rables e Ne m lange
10. off Water does not get hot cold enough Temperature is erratic Water pressure is poor Unit outputs both hot and cold water but the water does not mix Possible Cause sealing ting trom flushing plug still inside roug ceramic plate s inside cartridge damaged handle screw not tightened normal clearing of showerhead ceramic plate s damaged high temperature limit stop not set properly handle not justified thermostat cartridge is faulty thermostat cartridge is faulty filters on thermostat cartridge are clogged not a product defect hot and cold supplies are reversed Solution remove sealing ring replace cartridge tighten handle screw not a problem replace cartridge reset high temperature limit stop justify handle replace thermostat cartridge replace thermostat cartridge clean the filters correct the plumbing Fran ais Corps d encastrement ThermoBalance lll 06624000 Corps d encastrement ThermoBalance lll avec but es d arr t 06628000 Pour le bien de clart le i box n est pas montr e dans cette illustration Ne pas enlevez le i box min 1 3 3 max 2 3 3 L l ment thermostatique illustr ici est compris avec le jeu de garniture ATTENTION Le corps d encastrement 06628000 est munie de but es d arr t arr t d isolation int gr es la valve Lorsque les fentes sont l horizontale les but es d arr t sont la position on Lorsque les fente
11. ThermoBalance Ill Rough and Trim C Lever C Scroll C Cross 06067XX0 06068XX0 Solaris E Allegro E Metro E 04148XX0 04154XX0 04160XX0 31318XX1 31737XX1 32318XX1 ansgrone English ThermoBalance lll Rough Valve 06624000 ThermoBalance Ill Rough Valve with Stops 06628000 min 1 3 s max 2 3 3 The cartridge shown is included with the trim kit The Service Isolation Stops For the sake of clarity the plastic installation box i box is not shown in these illustrations Do not remove the i box Rough valve 06628000 has service stops isolation stops built onto the valve When the slots are horizontal the stops are in the on position When the slots are vertical the stops are in the off position Use a 3 mm Allen wrench to open and close the CAUTION When connecting the hot and cold supplies hold the stop steady with a wrench to avoid stop misalignment and breakage of the factory sealed thread compound English Installation considerations For best results this valve should be installed by a licensed professional plumber Large pressure differences between the hot and cold supplies should be balanced for proper operation of the valve Before beginning the installation read the instructions thoroughly Inspect the product and be sure that all parts are present and in good condition If you have questions or concerns regarding this installation please c
12. ace lorsque vous retirez ou remplacez la cartouche thermostatique Rincez les d bris ou d p ts pouvant se trouver dans les tamis de filtre Au besoin brossez d li catement l aide d une brosse dent douce Ne retirez pas les tamis Lubrifiez les joints toriques avec de la graisse blanche de plomberie Tenez fermement le dispositif d arr t en place R installez et serrez la cartouche thermostatique Installez l cusson R glez et installez la poign e g poig 26 D pannage Probl me Fuites entre l l ment thermosta tique et la pi ce interieure La poign e tourne mais l eau ne coule pas ne se ferme pas l eau continue de d goutter pendant plusieurs minutes apr s a fermeture du robinet l eau Argonne continuellement une fois le robinet ferm L eau n est pas assez chaude froide La temp rature est irr guli re La pression d eau est faible L eau est soit chaude soit froide mais il est impossible d obtenir de l eau ti de Cause Possible Le joint du bouchon de rin age est encoure l int rieur Une ou des plaques de c ramique de l l ment thermostatique sont endommag es La vis de la poign e n est pa serr e D gagement normal d une pomme de douche Une ou des plaques de c ramique sont endommag es La but e limite d eau chaude n est pas r gl e La poign e n est pas r gl e La cartouche thermostatique est d fectueuse La cartouche thermostatique est
13. e tub spout is connected to outlet I Outlets ll amp lll can be run either individually or simultaneously e na three function shower the user must decide PRIOR TO INSTALLATION which two functions he she wishes to be able to run at the same time These two functions must be plumbed from outlets Il amp lll Additionally he she must decide which function he she wants to have come on first As the handle is turned from the off position outlet ll will come on first Suggested Layouts three feature systems These are the most common installations using the ThermoBalance lll valve but are not the only ones possible The handshower is plumbed to outlet 1 it can only be run by itself The shower head is on 2 and the bodyjets on 3 The showerhead and bodyjets can be run either individually or at the same time The showerhead comes on first In this tub shower installation the tub spout is on outlet 1 and can only be run by itself The showerhead and handshower on outlets 2 and 3 can be run either individually or at the same time The showerhead comes on first English Special Piping the two feature system Do not plug any outlet on the In this installation the user wished to ThermoBalance III be able to use the showerhead and the bodysprays simultaneously Note how outlet 1 is also connected to the showerhead Instal
14. ent tre remplac s sous peine d entrainer des blessures Les dommages dus un mauvais traitement ne sont pas couverts par la garantie Limited Lifetime Consumer Warranty This product has been manufactured and tested to the highest quality standards by Hansgrohe Inc Hansgrohe This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1 1996 and installed in either the United States or Canada WHO IS COVERED BY THE WARRANTY This warranty extends to the original consumer purchaser only This warranty is non transferable WHAT IS COVERED BY THE WARRANTY This warranty covers only your Hansgrohe manvfactured product Hansgrohe warrants this product against defects in material or workmanship as follows Hansgrohe will repair at no charge for parts only or at its option replace any product or part of the product that proves defective because of improper workmanship and or material under normal installation use service and maintenance If Hansgrohe is unable to provide a replacement and repair is not practical or cannot be timely made Hansgrohe may elect to refund the purchase price in exchange for the return of the product LENGTH OF WARRANTY Replacement or repaired parts of products will be covered for the term of this warranty as stated in the following two sentences If you are a consumer who purchased the product for use primarily for personal family or household purp
15. ge pr vient le d bit crois Il n emp chera pas toutefois l eau de circuler dans les conduites de sortie Si l habitation doit tre mise sous pression avant l installation de l l ment thermostatique fermez les but es d arr t ou obtu rez les conduites de sortie Fran ais ThermoBalance lll Jeux de Les instructions ci apr s s appliquent aux mod les suivants garniture Robinet mitigeur Ensemble mitigeur Ces jeux de garniture sont con us seulement pour la douche pour les corps d encastrement C Cross 06069XX0 06116XX0 ThermoBalance lll 06624000 C Scroll 06068XX0 06115XX0 06628000 C Lever 06067XX0 06114XX0 Le mur doit tre compl tement fini Solaris E 04148XX0 et tanche avant l installation de Allegro E 04154XX0 cet ensemble de garniture Metro E 04160XX0 Metris S 31318XX1 31325XX1 Focus S 31737XX1 31775XX1 Talis S 32318XX1 32325XX1 Solaris E 06637XX0 06643XX0 Stratos E 06581XX0 06587XX0 06657XX0 06663XX0 06067XX e a 06637XX0 06581XX0 20 Installation Avant de commencer fermez l eau la vanne prin cipale ou aux but es d arr t Coupez la bo te d installation i box de fa on ce qu elle d passe de la surface du mur fini de 1 16 po Scellez le mur autour de la boite d installation l aide d un agent d tanch it Retirez l tiquette Coupez les huit branches de support reliant le bou chon de rin age la boite d installation i b
16. grohe Inc 1492 Bluegrass Lakes Parkway Alpharetta GA 30004 Toll free 800 334 0455 In requesting warranty service you will need to provide 1 The sales receipt or other evidence of the date and place of purchase 2 A description of the problem 3 Delivery of the product or the defective part postage prepaid and carefully packed and insured to Hansgrohe Inc 1492 Bluegrass Lakes Parkway Alpharetta Georgia 30004 Attention Technical Service if required by Hansgrohe When warranty service is completed any repaired or replacement product or part will be returned to you postage prepaid EXCLUSIONS AND LIMITATIONS REPAIR OR REPLACEMENT OR IN LIMITED CIRCUMSTANCES REFUND OF THE PURCHASE PRICE AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE PURCHASER HANSGROHE NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO CREATE FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THIS PRODUCT HANSGROHE SHALL NOT BE LIABLE TO PURCHASER OR ANY PERSON FOR ANY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY INCLUDING MERCHANTABILITY Some States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply fo you This warranty gives you specific legal rights and you may have other rights which vary from State to State You may be required by law to give us a reasonable opportunity to correct or cure
17. lation qu Caution Turn the water off at the main before continuing Install the hot and cold supply lines on the rough The hot supply must be connected to the hot inlet and the cold supply must be connected to the cold inlet In an older home confirm that the hot and cold supplies are not reversed If the supplies are not connected to the correct inlets the valve cannot function correctly Model 06628000 only When connecting the hot and cold supplies hold the stop steady with a wrench to avoid stop misalignment and breakage of the factory sealed thread compound Install all outlet lines Do not plug any outlet For the sake of clarity the i box is not shown in this illustration The valve should be level in all planes English Install the rough so that the outside surface of the finished wall falls between the minimum and maximum lines on the installation box i box This will insure that the trim fits correctly The i box must remain on the valve Install the wall material up to the i box When the trim is installed the i box will be trimmed nearly flush with the finished wall and sealed to provide protection against water damage Flush the supplies using the flushing plug The i box incorporates a flushing plug to permit line flushing and pressure testing before the car tridge and trim are installed A pressure test of the piping shou
18. ld be performed before the walls are closed The flushing plug permits hot water to flow through outlets amp Il and the cold water to flow through outlet III Install hose bibbs and hoses to the outlets Flush the lines for at least 5 minutes Use the hoses to direct the water to a location where it will not cause damage The flushing plug prevents cross flow However it will not stop the flow of water through the outlets If the building is to be pressurized prior to instal lation of the cartridge close the stops or plug the outlets Miminum wall thickness het WARNING caliente chaud Maximum wall thickness English ThermoBalance lll Trim Kits These instructions cover the following trim kits These trim kits are for use with Valve Trim Shower Set Trim rough valves 06624000 and C Cross 06069XX0 061 16XX0 06628000 only C Scroll 06068XX0 06115XX0 C Lever 06067XX0 06114XX0 The finished wall must be complete Solaris E 04148XX0 and made watertight before Allegro E 04154XX0 installation of this trim kit Metro E 04160XX0 Metris S 31318XX1 31325XX1 Focus S 31737XX1 31775XX1 Talis S 32318XX1 32325XX1 Solaris E 06637XX0 06643XX0 Stratos E 06581XX0 06587XX0 Metro E 06657XX0 06663XX0 06637XX0 06581XX0 English Installation a Turn the water off at the main or at the stops before beginning Cut the installation box i box so tha
19. make the water warmer The temperature control will stop when the water is 100 this is the safety stop To override the safety stop press inward on the temperature control and continue to turn it counter clockwise Important the temperature control will not automatically reset to below 100 F when the water is turned off 12 English Maintenance Clean the filter screens CAUTION Turn off the water to the valve either at the main or with the service stops before beginning Remove the handle and escutcheon stop unit Grasp the wrench flats on the stop unit with an wrench flat adjustable wrench Hold the stop unit steady Use a second adjust able wrench or 17 mm deep socket wrench to unscrew and remove the thermostatic cartridge Failure to hold the stop unit steady Q while removing or replacing the thermostat cartridge will result in damage to the stop unit Rinse the debris from the filters Scrub gently with a soft toothbrush if necessary Do not remove the screens Lubricate the o rings with white plumbers grease Hold the stop unit steady Reinstall and tighten the thermostatic cartridge Install the escutcheon Justify and install the handle English Troubleshooting Problem Water leaks between cartridge and rough Handle turns but water does not turn on off Water drips for several minutes after the valve is turned off Water drips continuously after the valve is turned
20. onal IMPORTANT Many municipalities have codes limiting the maximum discharge tempera ture of a shower valve to 110 F or less In Massachusetts the discharge temperataure can be no higher than 112 F Please know and follow all applicable local plumbing codes When setting the high temperature limit stop Tools required Thermometer 3 mm Allen wrench Turn the Water on using the handle Loosen the handle screw Remove the handle Remove the clip and stop ring from the thermostatic cartridge stem Turn the thermostatic mixer stem until the output water is the desired maximum high tempera ture usually 110 F Reinstall the stop ring so that it is against the stop Reinstall the clip Justify and reinstall the handle English User Instructions The ThermoBalance lll has two control features the temperature control knob and the volume control diverter lever The volume control diverter lever controls the water flow The center position is off Turn the handle counter clockwise to send the water to outlet 1 Turn the handle clockwise to send the water to outlet ll When the handle is between Il and Ill water will come from both Continue turning the handle counter clock wise to send the water to outlet Ill It is not possible to run all three outlets simultaneously Turn the temperature control clockwise to make the water cooler Turn the temperature control counter clockwise to
21. ontact Hansgrohe Technical Services at 800 334 0455 Rough valve 06624000 does not include service stops If stops are required by lo cal plumbing code order the stops separately item 06900003 or use rough valve 06628000 This ThermoBalance Ill rough valve is for use in a three function shower only All outlets must be plumbed Do not plug any outlet If a two function shower with a shared function is desired follow the special piping instructions on page 5 The ThermoBalance lll rough requires a ThermoBalance Ill trim kit Do not attempt to use any other trim kit Do not attempt to use this valve with a diverter tub spout Technical Information Recommended water pressure 45 72 psi Max hot water temperature 165 F Recommended hot water temperature 120 F 140 F Nominal capacity 45 psi 6 gpm Nominal capacity 60 psi 7 gpm Safety stop 100 F Max output temperature 110 F Yo NPT connections Listed by IAPMO Please know and follow all applicable local plumbing codes when setting the temperature on the water heater The high temperature limit stop may be reset to comply with local plumbing codes Refer to the trim kit installations g P p may ply P g 3 English A look at the ThermoBalance lll e The ThermoBalance lll has one outlet on the bottom of the valve outlet I and two on the top of the valve outlets II amp Ill e Outlet can only be run by itself In a tub shower installation th
22. oses this warranty extends for as long as you own the product and the home in which the product is originally installed If you purchased the product for use primarily for any other purpose including without limitation a commer cial purpose this warranty extends only i for 1 year with respect to Hansgrohe and Commercial products and ii for 5 years with respect to AXOR products THIS WARRANTY DOES NOT COVER AND HANSGROHE WILL NOT PAY FOR A Conditions malfunctions or damage not resulting from defects in material or workmanship B Conditions malfunctions or damage resulting from 1 normal wear and tear improper installation improper maintenance misuse abuse negligence accident or alteration or 2 the use of abrasive or caustic cleaning agents or no rinse cleaning products or the use of the product in any manner contrary to the product instruc tions 3 Conditions in the home such as excessive water pressure or corrosion C Labor or other expenses for the disconnection deinstallation or return of the product for warranty service or for installation or reinstallation of the product including but not limited to proper packaging and shipping costs or for installation or reinstallation of the product 30 D Accessories connected materials and products or related products not manufactured by Hansgrohe TO OBTAIN WARRANTY PARTS OR INFORMATION Contact your Hansgrohe retailer or contact Technical Service at Hans
23. ox Enlevez le bouchon de rincage Ne jetez pas les vis Assurez vous d avoir galement enlev le joint bleu du bouchon de rincage Ins rez l l ment thermostatique dans la pi ce int rieure La languette s ins re directement dans la coche de la pi ce int rieure Utilisez les vis du bouchon de rin age pour fixer la plaque d arr t de l l ment thermostatique la pi ce int rieure Serrez les vis uniform ment l aide d un tournevis manuel Ne serrez pas trop les vis Francais 21 Fran ais Attention Ex cuter ce test Ouvrez l eau Tourner le dispositif d arr t V rifiez l tanch it de tous les raccords Si une fuite se produit entre la pi ce int rieure et l l ment thermostatique fermez l eau Retirez l l ment thermostatique V rifiez que le joint du bouchon de rin age a bien t enlev R installez l l ment thermostatique Tourner le dispositif d arr t encore Si le probl me persiste contactez le Service la client le pour obtenir un l ment thermostatique de rechange Solaris uniquement cusson ovale Enclenchez les espaceurs Duotec blancs sur la plaque support Installez deux bandes Duotec sur les espaceurs Installez les deux autres bandes au dos de l cus son plaque de la garniture Tous les autres mod les cusson rond Installez deux bandes Duotec directement sur la plaque support In
24. s sont la verticale les but es d arr t sont la position off Utilisez une cl hexagonale de 3 mm pour ouvrir et fermer les but es d arr t Lors du raccordement des arriv es d eau chaude et froide tenez la but e d arr t l aide d une cl pour qu elle ne bouge pas afin de pr venir tout d salignement ou rupture des l ments filet s scell s en usine Fran ais A prendre en consid ration pour l installation e Pour de meilleurs r sultats cette valve devrait tre install e par un plombier professionnel certifi e les diff rences importantes de pression d arriv e d eau chaude et d eau froide doivent tre quilibr es pour que la valve fonctionne correctement e Veuillez lire attentivement les instructions avant de commencer l installation Examinez le produit et assurez vous qu aucune pi ce ne manque et qu elles sont toutes en bon tat Si vous avez des questions concernant cette installation n h sitez pas contacter les Services techniques de Hansgrohe au 800 334 0455 e la Corps d encastrement 06624000 ne comprend pas les but es d arr t Si le code de plomberie locale exige l utilisation de but es d arr t commandez les s par ment article 06900003 ou utilisez la Corps d encastrement 06628000 e Cette Corps d encastrement ThermoBalance lll est con ue pour les douches trois fonc tions seulement Toutes les conduites de sortie doivent tre raccord es Ne mettez de bouchon
25. stallez les deux autres bandes au dos de l cusson 22 Tous les mod les Installez la plaque support et le joint l aide des vis de la plaque support Pressez fermement l cusson sur la plaque sup port Les bandes Duotec se fixeront en place bien solidement Installez la poign e Serrez la vis de la poign e l aide d une cl hexagonale de 3 mm La vis de la poign e doit s engager dans la fente taill e dans le laiton sous l l ment thermostatique R glez la but e limite de l eau chaude en option voir page 23 R glage de la poign e R glage de la poign e Outils requis Thermom tre Cl hexagonale 3 mm Ouvrez la valve Placez le thermom tre dans le jet d eau Tournez le bouton de contr le de la temp rature jusqu ce que l eau qui s coule atteigne 100 F Fermez l eau l aide d une cl hexagonale de 3mm desserrez la vis de la poign e Retirez la poign e de la valve 1 D une main tenez le levier de la poign e et de l autre main faites tourner le bouton de contr le de la temp rature d environ Y2 tour dans le sens horaire 2a Ensuite sans appuyer dessus faites le revenir en le tournant dans le sens antiho raire jusqu ce qu il soit en position verticale et qu il atteigne l arr t de s ret 2b Installez la poign e 3 Serrez la vis Francais Fran ais R glage de la but e limite d eau chaude en option IMPORTANT Plusie
26. sur aucune des sorties e Si vous d sirez une douche deux fonctions avec une fonction partag e veuillez suivre les instructions de raccordement sp cial la page la pi ce int rieure ThermoBalance lll requiert le jeu de garniture ThermoBalance III N utilisez aucun autre jeu de garniture e N essayez pas de combiner cette valve un bec de baignoire inverseur Donn es techniques Pression d eau recommand e 45 72 psi Temp rature maximum pour l eau chaude 165 F Temp rature recommand e pour l eau chaude 120 F 140 F Capacit nominale 45 psi 6 gpm Capacit nominale 60 psi 7 gpm Arr t de s ret 100 F Temp rature de sortie maximale 110 F Raccords NPT po Accr dit par IAPMO Vous devez conna tre et respecter tous les codes de plomberie locaux applicables pour le r glage de la temp rature du chauffe eau Le degr de temp rature de la but e de limite d eau chaude peut tre r gl de fa on satisfaire aux codes de plomberie locaux Reportez vous aux installations des jeux de garniture 16 ThermoBalance lll en bref ThermoBalance lll comprend une sortie au bas de la valve sortie I et deux sur le dessus sorties ll et Il la sortie ne peut fonctionner avec aucune autre Dans une installation bain douche le bec de la baignoire est raccord la sortie I Fran ais les sorties ll et lll peuvent tre utilis es s par ment ou simultan ment
27. t it extends 1 16 outside the finished wall A Seal the wall around the i box with waterproof sealant Q Failure to seal the wall can lead to possible water damage Remove the label Cut the eight support arms that connect the flush ing plug to the i box Remove the flushing plug Do not discard the screws Be sure that the blue sealing A gasket is removed as well Failure to remove the gasket qa can result in possible damage to the cartridge and possible water damage Insert the cartridge in the rough The locator tab goes straight into the notch on the rough Use the flushing plug screws to connect the cartridge retainer plate to the rough Tighten the screws evenly with a manual screwdriver Do not over tighten the screws notch locator English A Perform the following test to check for damage to the ceramic plates inside the stop unit a Failure to correctly perform this test can result in possible water damage Turn on the water supplies Grasp the stop unit and turn it If there is a leak around the cartridge turn the supplies off and remove the cartridge Confirm that the sealing gasket from the flushing plug was removed Reinstall the cartridge Turn the stop unit If the unit continues to leak contact Hansgrohe Customer Service for a re placement cartridge Solaris only oval escutcheon Snap the white Duotec spacers onto the carrier plate
28. urs municipalit s appliquent des codes limitant la temp rature de sortie maximale d un robinet de douche 110 F ou moins Dans le Massachusetts la temp ra ture ne doit pas exc der 112 F Assurez vous de bien conna tre et de respecter tous les codes de plomberie locaux applica bles lorsque vous effectuez le r glage pour le r glage de la but e limite d eau chaude Outils requis Thermom tre Cl hexagonale 3 mm Ouvrez l eau l aide de la poign e Desserrez la vis de la poign e Retirez la poign e Retirez l trier et la bague de retenue de la tige de la cartouche thermostatique Tournez la tige du mitigeur thermostatique jusqu ce que la temp rature de l eau chaude atteigne le degr voulu habituellement 110 F R installez la bague de retenue de fa on ce qu elle s appuie sur la but e d arr t R installez l trier R glez et r installez la poign e 24 Fran ais Instructions l intention de l utilisateur Le ThermoBalance lll est pourvu de deux fonctions de contr le le bouton de contr le de la temp ra ture et le levier de contr le d bit inverseur Le levier d bit inverseur contr le le d bit de l eau La position centrale est celle de l arr t off m Tournez la poign e dans le sens antihoraire pour envoyer l eau la conduite 1 Tournez la poign e dans le sens horaire pour envoyer l eau la sortie Il Continuez tourner la poign
29. z jamais deux produits de nettoyage e N utilisez jamais de produits articles de nettoyage de nature abrasive tels que poudres de nettoyage tampons ponge ou chiffons microfibre non appropri s 29 Instructions de nettoyage pour robinetteries et douches Veuillez suivre les instructions du fabricant de produits articles de nettoyage De plus tenez compte des conseils suivants Nettoyez vos produits de robinetterie et de douche aussi souvent que n cessaire e Utilisez la quante de produit nettoyant et respectez la dur e recommand e par le fabricant Ne laissez pas le produit sur les articles de robinetterie plus longtemps que n cessaire e Un nettoyage r gulier peut pr venir la formation de d p ts calcaires Si vous utilisez des nettoyants en vaporisateur vaporisez d abord sur une ponge ou un chiffon Ne vaporisez jamais directement sur un robinet des gouttelettes pourraient s infiltrer dans les ouvertures et les interstices et endommager celui ci e Apr s le nettoyage rincez abondamment avec de l eau propre pour liminer tout r sidu de produit nettoyant Important Les r sidus de savon liquide de shampoing et de mousse pour la douche peuvent galement endommager la robinette rie rincez donc avec de l eau propre apr s utilisation de ces produits Vevillez noter si la surface est d j endommag e les produits de nettoyage l endommageront encore plus Les composants dont la surface est endommag e devrai
Download Pdf Manuals
Related Search
Related Contents
Florence 1570-8VDB Use and Care Manual Lindy 42808 Network Card User Manual Harbor Freight Tools 4019 User's Manual Samsung SL-M2026W Kasutusjuhend Hinweis Copyright © All rights reserved.
Failed to retrieve file