1. 21 22 WARRANTY WANG o cec eta i Reed 23 Warranty registration 23 ABOUT YOUR NEW THERMOSTAT WARNING Do not use sharp instruments to press touch screen Only use your fingertips THERMOSTAT FEATURES e Large touch screen with adjustable backlight constant backlight available e Message center provides feedback and instructions e day programmability or separately programmable weekday weekend schedules e Thermostat can be removed from the wall for easy programming batteries must be installed e Front battery door access for fast easy replacement e Displays room temperature room humidity temperature setting and optional outdoor temperature e Air filter humidifier dehumidifier and HVAC service indicators e Programmable fan control with fan circulation mode e Fasy to use temperature control can override program schedule at any time e Progressive recovery ensures proper temperature at the start of a program event e Built in compressor protection prevents damage to your equipment e R5485 communications ready Universal system compatibility e Configurable to control a humidifier and dehumidifier ABOUT YOUR NEW THERMOSTAT ABOUT YOUR NEW THERMOSTAT CONTROLS amp DISPLAY OVERVIEW HOME SCREEN CONTROLS amp DISPLAY OVERVIEW MAIN MENU ROOM TEMPERATURE CURRENT DAY OUTDOOR TEMPERATURE ROOM RELATIVE HUMIDITY TEMPERATURE SETTING
2. Model 8800 Universal rilaire Communicating Thermostat Owner s Manual Includes HG Rif FILTER Operating Instructions and i5 pm Warranty Information READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS ABOUT YOUR NEW THERMOSTAT Thermostat features 3 Controls amp display overview 4 5 OPERATION Select system mode HEAT COOL 6 Change temperature set point 6 Select fan setting ON AUTO CIRC 7 Clean Screen 7 Maintenance reminders 7 Battery replacement 8 HUMIDISTAT FUNCTIONS Humidistat control screen 9 How to enter the setup menu to change Humidistat Mode 10 NETWORK FEATURES Network 11 vei e 11 Status indicators 11 PROGRAMMING Set time and date 12 Understanding program schedules 13 14 Progressive 14 Changing program schedules 15 16 Program schedule holds S secre eeu tasa p teca 17 18 DR 18 19 SETUP MENU How to enter the setup menu to change 20 User system settings table
3. CLEAN SCREEN LOCKOUT TOUCH SCREEN Aprilaire TEMPERATURE rilaire FOR 30 SECONDS FAN MODE ADJUSTMENT SETTING Fam SET VACATION HOLD et lo SYSTEM MODE 30 HOLD BUTTON BUTTON Outside IN PROGRAMMABLE MODE mr SETS OR CLEARS HOLD SET CURRENT TIME SYSTEM MODE NETWORK OVERRIDE yg SETTING SET CURRENT DATE ININITN HEAT PUMP MODE ONLY E EMERGENCY AUXILIARY HEAT RED INDICATOR SHOWS THROUGH HOUSING MESSAGE DONE BUTTON CENTER SCROLLING TEXT EXIT MENU LOW BATTERY INDICATOR CURRENT TIME amp DATE MAIN MENU BUTTON USER SYSTEM SETTINGS NOTE BACKLIGHT IS ACTIVATED WITH FIRST BUTTON PRESS AND AUTOMATICALLY TURNS OFF OPERATION SELECT SYSTEM MODE EM HEAT HEAT OFF COOL AUTO Press MODE to select EM HEAT only for heat pumps with auxiliary heat Thermostat controls auxiliary heat Heat pump will not operate in EM HEAT mode HEAT Thermostat controls only the heating system OFF Heating and cooling systems are off COOL Thermostat controls only the cooling system AUTO if enabled in installer setup Thermostat automatically selects heating or cooling depending on the indoor temperature Press DONE to save and exit or CANCEL to exit without saving The thermostat will save and exit if nothing is pressed within 10 seconds CHANGE TEMPERATURE SET POINT Press 4 or W to adjust the current set point See Program Schedule Holds on pages 17 19 for more inf
4. Press SET VACATION to enter vacation program hold Press amp W to adjust the temperature setting PROGRAMMING PROGRAM SCHEDULE HOLDS VACATION CONTINUED VACATION PROGRAM HOLD continued Press Next then FAN to set the fan mode Press Next then or W to set end date SET VACATION ENT DATE Back Next gt 6 90 LJL J PM 7 es 0 Press Next then or W to set end time T I DUOT TNI SET VACATION END TTM INU d unl Back GET VRCRT ION FAN MOD Back Next 6 00 LILI PM 725 D Press DONE to save and exit or CANCEL to exit without saving The thermostat will save and exit if nothing is pressed within 20 seconds SETUP MENU HOW TO ENTER THE SETUP MENU TO CHANGE SETTINGS Press or W to adjust the setting Selected option flashes Press DONE to save and exit or CANCEL to exit without saving Press MENU to enter the main menu Press SETUP to enter the setup menu The thermostat will discard changes and exit if nothing Is pressed within 60 seconds SETUP DONE Press Next or Back to page through the settings the setting is displayed in the message center MESSAGE CENTER SCROLLING TEXT LEMRERATURE SCAL FAHRENHEIT 20 SETUP MENU USER SYSTEM SETTINGS TABLE The following table is the list of the settings and their details Default settings are shown in bold System setting Descri
5. TEXT NETWORK FEATURES NETWORK OVERRIDE The network override feature is only available to be enabled when the thermostat is set to non programmable mode or humidistat mode When enabled this feature can be used by pressing HOLD SECURITY A four digit security PIN can be enabled to restrict access to the system If you forget your PIN you can access the thermostat with the master PIN 7777 STATUS INDICATORS The status indicator is located at the top of the screen When the thermostat sends or receives messages the bars flash across the screen The message center will display COMMUNICATION LOST if the thermostat has not received communications in the last 15 minutes BARS FLASH ACROSS SCREEN PROGRAMMING SET TIME SET DATE Press MENU to enter the main menu Press SET DATE to enter date menu Press MENU to enter the main menu Press SET CLOCK to enter clock menu Press or W to set the hour Press 4 or W to set the month GET HOURS GET MONTH Next Next blo ig ww 1 25 10 Press Next then or W to set the minute Press DONE to save and exit or CANCEL to exit without saving The thermostat will save and exit if nothing is pressed within 20 seconds Press Next then or W to set the day Press Next then or W to set the year Press DONE to save and exit or CANCEL to exit without saving The thermostat will save and exit if nothing is pressed
6. within 20 seconds PROGRAMMING UNDERSTANDING PROGRAM SCHEDULES The daily schedule is split into four events WAKE temperature you would prefer to wake up to LEAVE temperature when you are away from the house RETURN temperature you would prefer to return home to SLEEP temperature you would prefer while sleeping The times shown in the table below are the defaults The start time and temperature of each section can be changed to fit your schedule See Changing Program Schedules section on pages 15 16 This thermostat is pre set to use the following program settings recommended by the Department of Energy see table below These settings are intended to reduce your heating cooling expenses The fan program is pre set to AUTO for all events Set temperature Event designator Start time Heat Cool Fan WAKE 6 00AM 217C 62 F 417 C 10 F 219G 62 F 17 C 85 F 29 C 78 F 26 C LEAVE 8 00AM RETURN 5 00PM SLEEP 10 00PM PROGRAMMING PROGRAMMING UNDERSTANDING PROGRAM SCHEDULES CONTINUED CHANGING PROGRAM SCHEDULES Optionally the thermostat can be set to a two event or commercial schedule See Setup Menu on page 20 Press MENU to enter the main menu Press Next then 4 amp or W to set the start time of Press SET SCHEDULE to enter schedule programming the first event Set temperature Event designator Start time Heat Cool Fan GET WAKE EVENT GTART_TIME I LR WAKE OCCUPIED 6 00
7. AM 70 F 21 C 78 F 26 C AUTO LEAVE UNOCCUPIED 10 00PM 62 F 17 C 82 F 28 C AUTO PROGRESSIVE RECOVERY Press 4 or W to select the day TUE WED THU FRI SAT SUN Press Next then 4 or W to set the setpoints of the first event The Progressive Recovery feature allows the thermostat to activate the heating and cooling equipment prior to an event in order to reach the desired temperature at the start of the next scheduled event Example If the WAKE time is 6 am and the set temperature is 70 the heat will come on before 6 am so the temperature is 70 by the time you wake at 6 am FIC CE INI USE DUNIN 1G SELECT cr ADJUST HEAT AND 10 00 COOL SETPOINTS Back Next pus 6 00 Note This step is not displayed for weekday weekend schedules PROGRAMMING CHANGING PROGRAM SCHEDULES CONTINUED Press Next then FAN to set the fan mode of the first event 19 SCHEDULE PRES F AN 70 SELEC CT FAN MOTE Cool k Next UU Press Next to advance to the next event Repeat above process for each remaining event Press DONE to save the schedule for the day The thermostat will display the COPY option CnOv Moning CU i LILIEN UET I IF YES COPY Press COPY to copy the schedule of the day just programmed to any other day OR Press CANCEL to proceed to the next day and repeat the above process
8. C powered device with a battery back up for the clock BUTTON ROOM RELATIVE HUMIDITY ROOM RELATIVE HUMIDITY SETPOINT CURRENT DAY The thermostat has a memory backup that saves the eoe thermostat s settings in case of a power interruption The Model 8800 has the option of being configured as a humidistat that can control a humidifier and dehumidifier The system settings will be retained but the clock will rilaire reset after 90 seconds with no battery or AC power Replace the batteries every year or when the low battery indicator comes on Ig E The reset button located under the battery cover can be Outside used to reset the thermostat to factory defaults MESSAGE CENTER OUTDOOR TEMPERATURE SCROLLING TEXT 4 WARNING DEHUMIDIFIER ADJUSTMENT The reset button should only be used by the installer NETWORK OVERRIDE CURRENT TIME IF ENABLED amp DATE MAIN MENU BUTTON HUMIDISTAT FUNCTIONS HOW TO ENTER THE SETUP MENU TO CHANGE HUMIDISTAT MODE Press MENU to enter the main menu Press 4 W to adjust the setting Selected option Press SETUP to enter the setup menu flashes Press DONE to save and exit or CANCEL to exit without saving The thermostat will discard changes and exit if nothing Is pressed within 60 seconds Press Next or Back to page through the settings until you get to the Humidistat Mode Setting the setting is displayed in the message center MESSAGE CENTER SCROLLING
9. NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE THERMOSTAT ITSELF IMPLIED WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF DEFECT S RESULT FROM FAILURE TO HAVE THIS THERMOSTAT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusions or limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This equipment if installed in strict accordance with the manufacturer s instructions complies with the limits for a Class B computing device pursuant to Subpart J of Part 15 of FCC Rules WARRANTY REGISTRATION Please Take a few minutes to visit us on line at www
10. PROGRAMMING PROGRAM SCHEDULE HOLDS TEMPORARY TEMPORARY PROGRAM HOLD Press amp or W to immediately adjust the temperature when the schedule is running This will temporarily hold the temperature setting until the next scheduled event Temp Hold Press 4 or W to adjust the end time of the hold If end time is not adjusted the Temporary Hold will end at the start of the next event Temp Hold CANCEL HOLD To cancel the Temporary Hold press CANCEL HOLD PROGRAMMING PROGRAM SCHEDULE HOLDS PERMANENT PERMANENT PROGRAM HOLD Press HOLD to permanently hold the temperature at Its current setting while the schedule is running This will override the temperature settings for all events With the thermostat in Permanent Hold the temperature setting and fan mode can be adjusted and will stay at that setting until the hold is cancelled Perm Hold To cancel the Permanent Hold press CANCEL HOLD PROGRAM SCHEDULE HOLDS VACATION VACATION PROGRAM HOLD This energy saving feature allows you to suspend the programmed schedule for extended periods of time The temperature you select will be maintained 24 hours a day until the vacation program hold end date and time Once the end date and time have been surpassed the previously programmed schedule will resume If you return earlier than expected press CANCEL HOLD to resume the programmed schedule Press MENU to enter the main menu
11. aprilaire com to register your Aprilaire product If you do not have on line access please mail a postcard with your name address phone number product purchased and date of purchase to Research Products Corporation BOX 1467 Madison WI 53701 Your Warranty Registration information will not be sold or shared outside of this company 23 P O Box 1467 Madison WI 53701 1467 Phone 800 334 6011 e Fax 608 257 4357 www aprilaire com 61000762 1 12 B2205383C 2012 Aprilaire A division of Research Products Corporation
12. ormation OPERATION SELECT FAN SETTING ON AUTO CIRC When the fan mode is changed during a program event It remains in that mode until the next event starts The fan must be programmed to FAN ON in the schedule to run continuously through all events Press FAN to select ON Fan runs continuously Use this mode for maximum air circulation cleaning AUTO Fan runs only when the heating or cooling system Is On CIRC Same as AUTO but ensures the fan is on for at least 20 minutes per hour Use this mode for a balance of energy savings and air circulation cleaning Press DONE to save and exit or CANCEL to exit without saving The thermostat will save and exit if nothing is pressed within 10 seconds CLEAN SCREEN Press MENU to enter the main menu Press CLEAN SCREEN to disable the touch screen for 30 seconds for cleaning Note Use a soft damp cloth to clean the screen Use water or household glass cleaner Do not spray liquids directly on the screen MAINTENANCE REMINDERS Maintenance reminders are set up by the installer to indicate when the equipment is due for service If a maintenance reminder is displayed call your HVAC dealer for service They can be cleared by pressing MENU to enter the main menu then Next to clear each reminder OPERATION HUMIDISTAT FUNCTIONS BATTERY REPLACEMENT HUMIDISTAT CONTROL SCREEN Batteries are not required for proper operation The thermostat is a 24VA
13. ption Factory default setting bold and setting range HUMIDISTAT MODE only available if controller type HUMIDIFY is set to humidistat DEHUMIDIFY AUTO OFF TEMPERATURE SCALE Set the thermostat to Fahrenheit FAHRENHEIT or Celsius mode CELSIUS AUTO DAYLIGHT Enable or disable auto daylight MARCH Second Sunday in March to the first Sunday SAVINGS savings in November APRIL First Sunday in April to the last Sunday in October OFF BACKLIGHT INTENSITY Backlight intensity as a 100 PERCENT percentage of full on selection of 0 10096 EVENTS PER DAY Number of program events FOUR EVENTS PER DAY per day TWO EVENTS PER DAY SECURITY Enable PIN code security feature DISABLED only available if enabled in ENABLED installer setup SECURITY PIN Sets security PIN code The thermostat can also be accessed 4 digit numeric PIN with the master PIN 7777 only available if Security is enabled 21 22 SETUP MENU USER SYSTEM SETTINGS TABLE CONTINUED Factory default setting bold and setting range OFF No lockout PARTIAL lockout FULL lockout MODE LOCKOUT System mode lockout setting only DISABLED available in partial lockout ENABLED FAN LOCKOUT Fan mode lockout setting only OFF No lockout available in partial lockout TIMED changes revert after temporary change period FULL no fan mode changes allowed OFF No lockout TIME LIMITED changes revert after temporary change period RANGE LIMITED set by max
14. setpoint lockout TIME AND RANGE set by max setpoint lockout and temporary change period FULL no setpoint changes allowed 5 F or C 5 RH OFF to 20 F or C OFF to 20 RH Description System setting LOCKOUT TYPE Level of lockout only available if Security is enabled SETPOINT LOCKOUT Setpoint lockout setting only TYPE available in partial lockout MAX SETPOINT Setpoint range limit for temperature CHANGE IN LOCKOUT and humidity adjustments only available in partial lockout TEMPORARY CHANGE Time limited lockout temporary 60 MINUTES PERIOD change period only available in partial 0 to 255 MINUTES lockout Enables the display of Support Module DISABLE temperature and humidity values in ENABLE the message center DISPLAY REMOTE SENSORS THERMOSTAT FIVE YEAR LIMITED WARRANTY Your Research Products Corporation Aprilaire Thermostat unit is expressly warranted for five 5 years from date of installation to be free from defects in materials or workmanship Research Products Corporation s exclusive obligation under this warranty shall be to supply without charge a replacement for any thermostat which is found to be defective within such five 5 year period and which is returned together with the date of installation no later than thirty 30 days after said five 5 year period by you to either your original supplier or to Research Products Corporation Madison Wisconsin 53701 THIS WARRANTY SHALL