Home
APC UPB50 Computer Hardware User Manual
Contents
1. as described in Figure 2 When the UPB50 has been stored or has not been attached to a notebook computer for 15 minutes or more it will enter Sleep Mode status To wake up the battery press the Status button for 1 3 second s and then release The status indicators will illuminate showing the battery is on and ready for use Sleep Mode Figure 2 LED Status Indications Status Indicators Lit When When Display Charging Discharging All LEDs off Fully charged 85 100 Less than 25 Less than 25 All LEDs F Changing Voltage While Battery is in Use If the output voltage selector switch is moved while the battery is in use output power to your notebook will be interrupted To resume power output ensure that the output voltage selector switch is set to the correct output voltage and press the Status button for 1 3 second s The status indicators will illuminate indicating the UPB50 has resumed power output Figure 3 Typical Connection Diagram aia roe adapter Ww Notebook tt Notebook power T computer AC power outlet Universal Notebook Battery G Specifications Capacity 53 Watt hours Output Power 70 Watts Maximum Continuous Power 80 Watts Peak Power short duration 16V 4 4A 19V 3 6A Output Voltage Input Power Source OEM notebook power adapter APC Universal Power Adapter Charge Time Recharges to 100 in 3 hours 8 66 x 2 76 x 0 87 220
2. with 15V 17V output Notebook computers with 18V 24V output 3 Press the Status button to make the changes effective This will also turn on the UPBSO If this is the first time using the battery connect a notebook power adapter to the UPB50O Refer to Section C Charging the Battery B Selecting the Correct Tips Plug Each is marked with an uppercase letter that corresponds to the notebook computer models listed in the Universal Notebook Battery Compatibility Guide It is used to connect output power from the UPB50 to the input DC voltage port on your notebook Jack Each is marked with a lowercase letter that corresponds to the notebook computer models listed in the Universal Notebook Battery Compatibility Guide It is used to connect the UPB50 to a power source such as your notebook power adapter or any APC Universal Power Adapter sold separately Example IBM X31 uses Plug B and Jack b See Figure 1 C Charging the Battery Once the output voltage setting and appropriate plugs jacks have been selected APC recommends fully charging the UPB50 prior to use See Figure 7 1 Attach the plug to the UPB50 output power connector 2 Attach the jack to the UPB50 input power connector 3 Connect your notebook s power adapter any APC Universal Power Adapter or other compatible power adapter to the battery 4 The UPB50 indicators should illuminate If not ensure the power adapter is connected to a
3. amage or reduce the life of the battery e Do not allow this product to come in contact with water or other liquids If any liquid should reach the interior of the battery immediately unplug the battery from your notebook Continued use of the battery is not recommended and may result in fire or electric shock e Do not expose the battery to a direct flame or heat source as the battery may explode Prior to Use This user manual provides operating instructions for the UPB50 Please read the entire user manual prior to use and remember to register your product You can do this via the enclosed warranty card or by visiting http warranty apc com and using keycode p668y Figure 1 Components Plug 1 Output power connector Jack db Input power connector Power connector j iiil LED status Output voltage indicators selector switch Status on J button a i oe J z j A Setting the Output Voltage Confirm that the UPB50 is compatible with your notebook computer by finding the corresponding model listing and voltage requirements in the Universal Notebook Battery Compatibility Guide Individual voltage ratings can also be found on your notebook computer s system label or power adapter label 1 Remove advisory sticker from output voltage selector switch 2 Slide the output voltage selector switch toward the symbol representing the notebook s required voltage Notebook computers
4. an 70W from the power Perform one of the following to resume the UPB50 power UPB5O output 1 Fully charge the notebook internal battery using the adapter provided with the notebook connect the UPB50 to the notebook OR Change the power settings on the notebook to conserve battery power When not connected to aj When the UPB50 has been stored Press the Status button for 1 3 second s and then release The notebook computer UPB50 does or has not been connected to a Status indicators will illuminate and the battery will resume power not provide power LED indicators notebook computer for 15 minutes output If no indicators are lit charge the UPB50 do not illuminate or more it will enter Sleep Mode status 1 Actual runtimes vary according to notebook model and power setting please refer to Runtime Chart I Recycling Storage and Battery Life The UPB50 should be disposed of properly Please do not incinerate or dispose of in trash receptacles For more information about APC s battery recycling program visit mobilecomputing apc com For best results do not store the UPB50 where there is excessive heat or cold as such environments can damage the battery pack and reduce battery life If storing the UPB50 for an extended period completely discharge and recharge the unit before the next use To completely discharge Attach the UPB50 to a notebook and wait until all LED indicators are off during use To completely ch
5. arge Attach any compatible notebook power adapter to the UPB50 and continue charging it until all Status indicators are extinguished For best results the UPB50 should be completely discharged and recharged once every 3 months This will condition the cells inside the battery and ensure the UPB50 delivers the most capacity available J Limited Warranty APC warrants its products to be free from defects in materials and workmanship under normal use and service for one 1 year from the date of purchase for the original purchaser Its obligation under this warranty is limited to repairing or replacing at its sole option any such defective products To obtain service under warranty you must obtain a Returned Material Authorization RMA number from APC or an APC Service Center with transportation charges prepaid It must be accompanied by a brief description of the problem and proof of date and place of purchase This warranty applies only to the original purchaser K Contact Information American Power Conversion 132 Fairgrounds Rd West Kingston RI 02892 USA Toll Free 800 800 4APC 800 800 4272 Toll 1 401 789 5735 Fax 1 401 789 3710 Internet http www apc com Copyright 2006 American Power Conversion All rights reserved APC is a registered trademark of American Power Conversion All other copyrights are the property of their respective owners Specifications are subject to change without notice Part 990 2475
6. mm x 70mm x 22mm Size H x W x D Weight 0 95 Ibs 432 g battery only 1 16 Ibs 525 g battery power cable one plug and one jack Environmental Storage 4 140 F 20 60 C Operation 32 104 F 0 40 C TUV GS cUL FCC CE C tick VCCI Note This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference which may cause undesired operation Agency Approvals H Troubleshooting The UPB50 is not charging the Notebook AC adapter output Check the voltage rating from the system label on the notebook or notebook when the AC adapter is voltage does not match the output power adapter Slide the output voltage selector switch to the connected to the UPB50 voltage setting on the output corresponding voltage Press the Status button for 1 3 seconds and voltage selector switch then release The LED indicators will illuminate and the battery will resume power output The UPB50 has automatically shut Remove the UPB50 from the enclosed area and let it cool for a few down due to abnormally high minutes Press the Status button for 1 3 second s and then release temperature The unit will recover from thermal protection mode The notebook being used is The UPB50 is designed to deliver 70 Watts of continuous output drawing more th
7. power source and the power source is ON See Troubleshooting for additional details 5 Charge the UPB50O for at least three hours or until fully charged prior to first use D Operation When the UPB5O0 is properly connected to your notebook computer the notebook computer will appear to be on utility power For optimal battery runtime adjust your notebook computer s power settings Refer to notebook user manual or control panel for more information on changing power mode settings If your notebook power adapter APC Universal Power Adapter or other compatible power adapter is removed from the UPB50O the UPB50 will serve as the primary power source for your notebook computer If any of these notebook adapters are present power will pass through the UPB50 to your notebook computer E Checking the Battery Status The status of the battery is indicated by four LED status indicators and can be checked at any time by pressing the Status button The various battery status conditions are described below Charge The LED status indicators will light up sequentially as each level of charge is reached Continue charging until the four white indicators are lit together and then turn off indicating the UPB50 is fully charged Discharge Press the Status button to display the discharge status The LED indicators will illuminate and display the remaining charge level The number of LEDs that light up indicate the level of discharge
8. www apc com 50 Watt Hour Universal Notebook Battery UPB50 User s Manual Introduction Thank you for purchasing APC s 50 Watt Hour Universal Notebook Battery UPB50 This slim lightweight external battery pack is compatible with many notebook computers in the market today Features e Compact design weighs less than one pound Up to four hours of additional runtime for your notebook computer e Two selectable output voltages e Four LED status indicators e Letter coded power tips provide compatibility with most notebook computers in the market today e Compatible with APC Universal Power Adapters e Up to 70 Watts continuous power and 80 Watts peak power Inspection Prior to use please check the package contents for the following items If any item listed below is not in the package please contact APC Customer Service at 800 800 4APC 800 800 4272 e Universal Notebook Battery UPB50 e Input Output Power Cable e Conversion Plug amp Jack Tips e Compatibility Guide Safety Precautions Please read the following warnings carefully before using the UPB50 Use the product according to the procedures outlined in this manual A Warnings e Caution Burn Hazard e Do not attempt to disassemble or alter any part of this product e Do not store outside of the following temperature range 4 140 F 20 60 C e Do not operate outside of the following range 32 104 F 0 40 C as this will d
Download Pdf Manuals
Related Search
Related Contents
Fujitsu LIFEBOOK S710 Thomson CR62 4- CCTP FBCVE&ST 2014 MANUAL DE INSTRUCCIONES 取扱説明書 - アロン化成株式会社 A User's Guide to MPI Enigmaze User`s Guide Altavoces Acústicos Montados en Caja Acústica CodeVisionAVR User Manual Copyright © All rights reserved.
Failed to retrieve file