Home

APC AP7900 Computer Accessories User Manual

image

Contents

1. m al YN U V U Q C im gt ua 134 Authentication of the server in this case the Rack PDU occurs each time a connection is made from the browser to the server The browser checks to be sure that the server s certificate is signed by a Certificate Authority known to the browser For this authentication to occur e Each Switched Rack PDU with SSL enabled must have a server certificate on the Rack PDU itself Any browser that is used to access the Rack PDU s Web interface must contain the CA root certificate that signed the server certificate If authentication fails the browser prompts you on whether to continue despite the fact that it cannot authenticate the server If your network does not require the authentication provided by digital certificates you can use the default certificate that the Rack PDU generates automatically The default certificate s digital signature will not be recognized by browsers but a default certificate enables you to use SSL for the encryption of transmitted user names passwords and data If you use the default certificate the browser prompts you to agree to unauthenticated access before it logs you on to the Web interface of the Rack PDU How SSH host keys are used An SSH host key authenticates the identity of the server the Switched Rack PDU each time an SSH client contacts the Rack PDU Each Switched Rack PDU with SSH enabled must have an SSH host key on the Rack
2. Note 32 Device and Outlet Management Menus How to Configure and Control Outlet Groups Outlet group terminology An outlet group consists of outlets that are logically linked together on the same Switched Rack PDU Outlets that are in an outlet group turn on turn off and reboot in a synchronized manner i e within a one second interval under normal conditions A local outlet group consists of two or more outlets on a Switched Rack PDU Only the outlets in that group are synchronized A global outlet group consists of one or more outlets on a Switched Rack PDU One outlet is configured as a global outlet which logically links the outlet group to outlet groups on up to three other Switched Rack PDUs All outlets in the linked global outlet groups are synchronized For global outlet groups the initiator outlet group is the group that issued the action For global outlet groups a follower outlet group is any other outlet group that is synchronized with the initiator outlet group When you apply an outlet control action to outlets that are members of an outlet group the outlets are synchronized as follows For a global outlet group use the delay periods and reboot duration configured for the global outlet of the initiator outlet group For a local outlet group the outlets use the delay periods and reboot duration of the lowest numbered outlet in the group m m al V cz o U te gt e
3. m al YN U V U Q C im gt ua Contents Introduction 1 Product Descriptio 6s 0 0 ose ddan 3 x 53 8 RE eee a ea ee 1 Access PrOCedlF6S uas n soo eR RR RACER Eee Re Ree eee 3 How to Recover From a Lost Password leen 6 Upgrading Firmware through a Serial Connection 8 Front Panel 54 533 m 0 he SS RUP RR RORIS AGER ER ee UR LS deris 10 Watchdog Features 4x xn sonam dei ee een eee eee eee OR n 14 Control Console 15 How to Log OM a eR OR habe FOES BEERS CORE Al 15 Maint SCEeen s uuum RR mum wh eee us x ui idis Bsa Dc ro iran 18 Control Console Menus ssh ee eee eee n 21 Web Interface 24 How to Log Oh f6 6 20 2tees sete RA REA d amim REOR EORR AUR RR a 24 S mmary Pade ceo yu 9 wd d eee ace CUI Aor qom eee ROAD we 27 Navigation Menu 5555 anoo hA ee seen ee RO d RR Rn 29 Device and Outlet Management Menus 33 How to Configure and Control Outlet Groups 33 Outlet Settings for Outlets and Outlet Groups 42 Switched Rack PDU Settings mik 00 0S Ane oH RORGEORon 46 Scheduling Outlet Actions Web Interface Only 49 Event Related Menus 53 IntroductiOD 6 666 ck ox ne ee wed ee ee ee ee 53 Event LOG 42 9 53343 433 9 9 Re Oe ea 55 Event Actions Web Interface Only eee eee 60 Event RecipleDES s saa eph RT RR E A GE se see RO nececa wana 63 E mail Feature as xus an ee aa a Rc 64 H
4. p A 2 Q ai U V aa U UV te Y gt N Purpose and benefits of outlet groups By using groups of synchronized outlets on Switched Rack PDUs you can ensure that outlets turn on turn off and reboot in a synchronized manner Synchronizing control group actions through outlet groups provides the following benefits e Synchronized shutdown and startup of the power supplies of dual corded servers avoids erroneous reporting of power supply failures during a planned system shutdown or reboot e Synchronizing outlets by using outlet groups provides more precise shutdown and restart timing than relying on the delay periods of individual outlets A global outlet is visible to the user interfaces of the Switched Rack PDUs to which it is linked Q Under normal conditions all outlets in outlet groups affected by a control action will perform that action within a one second interval Note 34 m m C x c o Q c gt e System requirements for outlet groups To set up and use synchronized outlet control groups You need a 10 100Base T TCP IP network with an Ethernet hub or switch that has a power source not shared by the computers or other devices being synchronized If outlets groups are to be synchronized across multiple Switched Rack PDUS those Switched Rack PDUs must meet the following requirements They must be on the same subnet They must use firmware that has t
5. Flashing Orange and The Rack PDU is making DHCP requests Green alternating T If you do not use a BOOTP or DHCP server see the nstallation and Quick Start manual provided in PDF on the Utility CD that came with your Rack PDU and as a printed manual to configure the TCP IP settings Load indicator LED The load indicator LED identifies overload and warning conditions for the displayed phase or bank m m C x c o Q c gt e Condition Description Solid Green The current of the displayed phase or bank is below the Current Overload threshold Yellow The displayed phase or bank is in a Near Overload Warning condition The current is above the Near Overload Warning threshold Red The displayed phase or bank is in an Overload condition The current is above the Overload Alarm threshold W atchdog Features Overview To detect internal problems and recover from unanticipated inputs the Rack PDU uses internal system wide watchdog mechanisms When it restarts itself to recover from an internal problem a System Warmstart event is recorded in the event log Network interface watchdog mechanism The Rack PDU implements internal watchdog mechanisms to protect itself from becoming inaccessible over the network For example if the Rack PDU does not receive any network traffic for 9 5 minutes either direct traffic such as SNMP or broadcast traffic such as an Addres
6. m m am MN U V U Q C UJ bam gt WY PDU can control access to its Web interface by user name password and account type e g Administrator Device Manager or Read Only User the browser cannot authenticate what Rack PDU is sending or receiving data The length of the public key RSA key that is used for encryption when setting up an SSL session is only 768 bits The public key used in Methods 2 and 3 is 1024 bits providing more complex encryption and consequently a higher level of security E m A aa U t v c Y ad gt V 128 Method 2 Use the APC Security Wizard to create a CA certificate and a server certificate You use the APC Security Wizard to create two digital certificates A CA root certificate Certificate Authority root certificate that the APC Security Wizard uses to sign all server certificates and which you then install into the certificate store cache of the browser of each user who needs access to the Rack PDU A server certificate that you upload to the Rack PDU When the APC Security Wizard creates a server certificate it uses the CA root certificate to sign the server certificate The Web browser authenticates the Rack PDU sending or requesting data To identify the Rack PDU the browser uses the common name IP address or DNS name of the Rack PDU that was specified in the server certificate s distinguished name when the certificate was create
7. 6 Press ENTER as many times as necessary to redisplay the User Name prompt then use the default apc for the user name and password If you take longer than 30 seconds to log on after the User Name prompt is redisplayed you must repeat step 5 and log on again m m ai e v Cz o U lt U s e 6 7 From the Control Console menu select System then User Manager 8 Select Administrator and change the User Name and Password settings both of which are now defined as apc 9 Press CTRL C log off reconnect any serial cable you disconnected and restart any service you disabled m m A x UJ A U U lt Y s WY Upgrading Firmware through a Serial Connection For a complete description of how to download a firmware upgrade for your Rack PDU see Upgrading Firmware Methods and Tools That section also explains how to use network based file transfer tools which complete a firmware upgrade more quickly than the XMODEM protocol described here which uses a serial connection You can use a local computer that connects to the Rack PDU through the serial port on the front panel of the unit 1 Select a serial port at the local computer and disable any service which uses that port 2 Use the supplied serial cable 940 0144 to connect the selected port to the serial port on the front panel of the Rack PDU 3 Run a terminal program such as HyperTerminal and configure the selected port f
8. U C im gt ua A About System 31 Access FTP Server 77 limiting NMS SNMP access by IP ad dress 85 security options for each interface 117 Access setting for RADIUS 102 Access Type setting 85 Actions 60 Advanced settings ClientID 75 112 Domain Name 74 112 Ethernet Port Speed 112 Host Name 74 112 On Retry Failure 76 Port Speed 75 Retry Then Fail 75 User Class 75 112 Vendor Class 75 112 APC Cookie 114 APC OS 31 Apply Local Computer Time 105 Authentication SNMP Traps 63 with SSL 124 Auto Logout 98 B Boot mode 110 Boot mode settings BOOTP only 74 DHCP amp BOOTP 74 DHCP only 74 Manual 74 174 BOOTP After IP Assignment setting 112 Boot mode settings 74 BOOTP Only boot mode setting 74 communication settings 75 DHCP amp BOOTP boot process 111 Remain in DHCP amp BOOTP mode setting 112 Status LED indicating BOOTP requests 13 Browsers CA certificates in browser s store cache 124 supported Web browsers 25 C Certificates choosing which method to use 126 creating and installing for SSL 126 methods APC Security Wizard creates all certificates 129 Use a Certificate Authority CA 131 Use the APC default certificate 127 CipherSuite Choosing SSL encryption ciphers and hash algorithms 92 purpose of the algorithms and ciphers 125 Client ID setting 75 112 Community Name 63 setting 84 config ini file contents 154 Configuring SSL TLS 88 Control console Device Manager menu 22
9. and by the Read Only User to log onto the Web interface only apc by default for Administrator device by default for Device Manager User readonly by default for Read Only User Password The case sensitive password maximum of 10 characters always used to log on at the control console but used to log into the Web interface only when Basic is selected for the Authentication setting apc is the default for the Password settings for all account types NOTE A Read Only User is not permitted to log on through the control console 98 m am MN U V Ee U Q C UJ gt V Outlet User Manager Use the Outlet User Manager option to set up user accounts that have access only to specified outlets Web interface Choose a user name or choose Add New User to edit accounts Setting Definition User Name The name of this user account NOTE A user name in orange indicates that the user account has been disabled Password Case sensitive password for this user account User Description Identification or description of the outlet user Account Status Enables or disables this user s account Outlet Access Selects the outlets to which users have access Delete User Deletes this user account 99 Control console Select System from the Control Console menu Then select Manage Outlet Users from the User Manager menu Setting Definition Add
10. certificates that you configured for Secure Sockets Layer for authentication at the Web interface File Transfer control console only Allows you to select one of the following to transfer firmware files to the Switched Rack PDU XMODEM A terminal emulation program that you can use only through a direct serial connection to the Switched Rack PDU FTP File Transfer Protocol FTP client application TFTP Trivial File Transfer Protocol TFTP client application Upload Web Interface only Upload a user configuration file ini file to the Switched Rack PDU To create the file retrieve settings from a configured Switched Rack PDU See How to Export Configuration Settings To upload the file in the User Configuration File section specify or browse to the file name and then click Upload 107 2 Q ai U V aa U UV te Y gt N Links Web interface Use this option to modify the links to APC Web pages Setting Definition User Links Name Defines the link names that appear in the Links menu by default APC s Web Site Testdrive Demo and Remote Monitoring URL Defines the URL addresses used by the links By default the following URL addresses are used http www apc com APC s Web site http testdrive apc com Testdrive Demo http rms apc com Remote Monitoring NOTE Only links of the type http can be used in these fields For infor
11. m m ai e Y Cz o U lt U s e navigating menus 21 refreshing menus 21 Cookie APC 114 Customizing user configuration files 156 D Data log configuration 70 Log Interval setting 70 using FTP to retrieve 57 data txt file importing into spreadsheet 57 Date amp Time settings 105 106 Delete SSH Host Keys and SSL Certificates 107 Device IP Configuration Wizard using to configure required TCP IP settings 150 Device Manager menu control console 22 DHCP After IP Assignment setting 112 APC cookie 114 Boot mode settings 74 Communication Vendor Class 75 communication settings 75 Cookie Is setting 112 113 DHCP amp BOOTP boot process 111 DHCP Only boot mode setting 74 Remain in DHCP amp BOOTP mode setting 112 Require vendor specific cookie to accept DHCP Address setting 112 113 response options 114 Retry Then Stop setting 113 Status LED indicating DHCP requests 13 175 DHCP amp BOOTP boot mode setting 74 Disabling e mail to a recipient 67 eventlogging 61 Reverse DNS Lookup 77 sending any traps to an NMS 63 sending authentication traps to an NMS 63 Syslog 86 Domain Name setting 74 112 Domain names for trap receivers 63 overriding expansion of host name to domain name 75 E E mail configuring 64 enabled by default for severe events 62 enabling and disabling 67 Events menu option 62 message format long or short 67 setting up an account 67 using for paging 66 Email recipients 66 for
12. signed certificates m A aa U t v c Y a gt V 132 Firewalls Although some methods of authentication provide a higher level of security than others complete protection from security breaches is almost impossible to achieve Well configured firewalls are an essential element in an overall security scheme m m A x UJ A U U lt Y s WY 133 Using the APC Security Wizard Overview Authentication Authentication verifies the identity of a user or a network device Such as an APC Switched Rack PDU Passwords typically identify computer users However for transactions or communications requiring more stringent security methods on the Internet the Switched Rack PDU supports more secure methods of authentication Secure Sockets Layer SSL used for secure Web access uses digital certificates for authentication A digital CA root certificate is issued by a Certificate Authority CA as part of a public key infrastructure and its digital signature must match the digital signature on a server certificate on the Rack PDU Secure SHell SSH used for remote terminal access to the Rack PDU s control console uses a public host key for authentication rather than a digital certificate How certificates are used Most Web browsers including all browsers supported by the Switched Rack PDU contain a set of CA root certificates from all of the commercial Certificate Authorities
13. the Rack PDU discards it and generates a valid one However a host key that the Rack PDU generates is only 768 bits in length A valid host key created by the APC Security Wizard is 1024 bits You can create a host key file with the APC Security Wizard and then upload it to the Rack PDU by using the Web interface Use the Browse button for the Filename field to locate the file then click Apply Alternatively you can use FTP or Secure CoPy SCP to transfer the host key file to the Rack PDU NOTE Creating and uploading a host key in advance reduces the time required to enable SSH If no host key is loaded when you enable SSH the Rack PDU creates one when it reboots The Rack PDU takes up to 5 minutes to create this key and the SSH server is not accessible during that time 83 Option Description SSH Host Key Fingerprint SSH v1 Displays the SSH version 1 fingerprint for the host key The fingerprint is a unique identifier to further authenticate the host key In the control console choose Advanced SSH Configuration and then Host Key Information to display the fingerprint SSH v2 Displays the SSH version 2 fingerprint for the host key The fingerprint is a unique identifier to further authenticate the host key In the control console choose Advanced SSH Configuration and then Host Key Information to display the fingerprint SNMP An Access option the Settings option in the control console en
14. 1024 bit RSA keys If you do not create and use SSL server Note Certificates and SSH host keys with the APC Security Wizard the Rack PDU generates 768 bit RSA keys Only APC server management and key management products can use server certificates host keys and CA root certificates created by the APC Security Wizard These files will not work with products such as OpenSSL and Microsoft IIS m m ai e V Cz o U lt U s e 136 Create a Root Certificate amp Server Certificates Summary Use this procedure if your company or agency does not have its own Certificate Authority and you do not want to use a commercial Certificate Authority to sign your server certificates The public RSA key that is part of a certificate generated by the APC Security Wizard is 1024 bits The default key generated by Note the Rack PDU if you do not use the Wizard is 768 bits Create a CA root certificate that will be used to sign all server certificates to be used with Switched Rack PDUs During this task two files are created The file with the p15 extension is an encrypted file which contains the Certificate Authority s private key and public root certificate This file signs the server certificates The file with the crt extension which contains only the Certificate Authority s public root certificate You load this file into each Web browser that will be used to access the Switched Rack PDU so that the brow
15. Canada 1 800 800 4272 toll free Latin America 1 401 789 5735 USA Europe Middle East Africa 353 91 702000 Ireland Japan 0 35434 2021 Australia New Zealand South 61 2 9955 9366 Pacific area Australia Local country specific centers go to www apc com support contact for contact information m m ai e v Cz o U lt U s e Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support 182 Copyright Entire contents 2005 American Power Conversion All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo InfraStruXure and PowerNet are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only 990 1368D 001 04 2005 m A aa U t v c Y a gt V 183
16. Cookie Is and Retry Then Stop that directly affect how DHCP is used see Boot Mode DNS Configure Domain Name System Settings fields Use these fields to define the IP addresses of the primary and secondary Domain Name System DNS servers used by the Switched Rack PDU e mail feature See E mail Feature and DNS servers Send DNS Query Web interface Use this option available only through the DNS menu in the Web interface to send a DNS query that tests the setup of your DNS servers Use the following settings to define the parameters for the test DNS request you view the result of the test DNS request in the Last Query Response field which displays No last query or text describing the query result of the last test Use the Query Type setting to select the method to use for the DNS query The URL name of the server Host The IP address of the server IP The fully qualified domain name FQDN The Mail Exchange used by the server MX Use the Query Question text field to identify the value to be used for the selected Query Type m m C x V c o Q c gt e 76 m m ai e V Cz o U lt U s e For Host identify the URL For IP identify the IP address For FQDN identify the fully qualified domain name formatted as myserver mydomain com For MX identify the Mail Exchange address Enable or disable Reverse DNS Lookup which
17. HTTP with the Rack PDU The default is 80 You can change the Port setting to the number of any unused port between 5000 and 32768 to enhance the protection provided by User Name and Password settings You must then use a colon in the command line to specify the non default port number For example for a port number of 5000 and a Rack PDU IP address of 159 215 12 114 you would use this command http 159 215 12 114 5000 HTTPS Port Identifies the TCP IP port used for communications by HTTPS with the Rack PDU The default is 443 You can change the Port setting to the number of any unused port between 5000 and 32768 to enhance the protection provided by User Name and Password settings You must then use a colon in the command line to specify the non default port number For example for a port number of 6502 and a Rack PDU IP address of 159 215 12 114 you would use this command https 159 215 12 114 6502 91 2 Q ai U V aa U UV te Y gt N Option Description SSL TSL Server Configuration CipherSuite Enables or disables the following SSL encryption ciphers and hash algorithms To access these options in the control console choose Web SSL then Advanced SSL TLS Configuration NOTE All of these encryption ciphers and hash algorithms use the RSA public key algorithm DES SSL RSA WITH DES CBC SHA a block cipher with a key length of 56 bits The
18. Local Password admin Service Type Administrative User UPSDevice Auth Type Local Password device Service Typ Login User UPSReadOnly Auth Type Local Password readonly 103 E m A aa U t v c Y baat gt n 3 Vendor specific attributes VSA can also be used This requires some dictionary entries VSAs take precedence over standard RADIUS attributes Example RADIUS dictionary apc dictionary apc VENDOR APC 318 Attributes ATTRIBUTE APC Service Type 1 integer APC ATTRIBUTE APC Outlets 2 string APC VALUE APC Service Type Admin 1 VALUE APC Service Type Devic 2 VALUE APC Service Type ReadOnly 3 VALUE APC Service Type Outlet 4 Example RADIUS users file with VSAs VSAAdmin Auth Type Local Password APC Service Type Admin VSADevice Auth Type Local Password APC Service Type Device VSAReadOnly Auth Type Local Password APC Service Type ReadOnly Give user access to device outlets 1 2 VSAOutlet Auth Type Local Password APC Service Type Outlet APC Outlets 1 2 3 user accounts 104 admin device readonly and 3 outlet For more information on user permission levels see Types of Identification Use this option to define the System Name Contact and Location values used by the SNMP agent for the Rack PDU The option s settings provid
19. Main menu The main control console menu has options that provide access to the management features of the control console 1 Device Manager 2 Network 3 System 4 Logout Q When you log on as Device Manager or as an Outlet User you will not have access to the Network or System menus Note Device Manager option This option accesses the Device Manager menu Select the components you want to manage from this menu To do any of the following tasks see Switched Rack PDU Settings 1 Phase Bank Monitor Configuration 2 Phase Bank Outlet Restriction Configuration 3 Outlet Control Configuration 4 Power Supply Status Option 4 is not available to outlet users 22 m A aa U t v c Y a gt V Network option To do any of the following tasks see Network Menu Configure the TCP IP settings for the Rack PDU or when the Rack PDU will obtain its TCP IP settings from a server configure the settings for the type of server DHCP or BOOTP to be used Use the Ping utility Define settings that affect the FTP Telnet Web interface and SSL SNMP e mail DNS and Syslog features of the Rack PDU System option To do any of the following tasks see System Menu Control Administrator Device Manager and Outlet User access Define the system Name Contact and Location values Set the date and time used by the Rack PDU Restart the Rack PDU Reset control console settings to their
20. Next to move from screen to screen 1 If the APC Security Wizard is not already installed on your computer install it by running the installation program APC Security Wizard exe from the APC Rack PDU Utility CD that came with your Rack PDU 2 On the Windows Start menu select Programs then APC Security Wizard to start the Wizard program 3 On the screen labeled Step 1 select SSH Server Host Key as the type of file to create 4 Enter a name for the file that will contain the host key The file name must have a p15 extension By default the file will be created in the installation folder C Program Files American Power Conversion APC Security Wizard 5 Click Next to generate the Host Key m m ai e V Cz o U lt U s e 6 The summary screen displays the SSH version 1 and version 2 fingerprints which are unique for each host key and identify the host key After you load the host key onto the Rack PDU you can verify that 146 the correct host key was uploaded by verifying that the fingerprints displayed here match the SSH fingerprints on the Rack PDU as displayed by your SSH client program 7 The last screen verifies that the host key has been created and instructs you on the next task to load the host key to the Switched Rack PDU It displays the location and name of the host key which has a p15 file extension Load the host key to the Rack PDU Perform these steps 1 On the Network menu of t
21. PDU itself Files you create for SSL and SSH security Use the APC Security Wizard to create the following components of an SSL and SSH security system The server certificate for the Switched Rack PDU if you want the benefits of authentication that such a certificate provides You can create either of the following types of server certificate m m al YN U V U Q C im bam gt WY 135 A server certificate signed by a custom CA root certificate also created with the APC Security Wizard Use this method if your company or agency does not have its own Certificate Authority and you do not want to use an external Certificate Authority to sign the server certificate A server certificate signed by an external Certificate Authority This Certificate Authority can be one that is managed by your own company or agency or can be one of the commercial Certificate Authorities whose CA root certificates are distributed as part of a browser s software e A certificate signing request containing all the information required for a server certificate except the digital signature You need this request if you are using an external Certificate Authority A CA root certificate An SSH host key that your SSH client program uses to authenticate the Rack PDU when you log on to the control console interface All public keys for SSL certificates and all host keys for SSH that are created with the APC Security Wizard are
22. Secure Hash Algorithm SHA is used for authentication 3DES SSL RSA WITH 3DES EDE CBC SHA a block cipher with a key length of 168 bits A Secure Hash Algorithm SHA is used for authentication e RC4 SSL RSA WITH RC4 128 MD5 a stream cipher with a key length of 128 bits with an RSA key exchange algorithm and with a Message Digest 5 MD5 hash algorithm used for authentication This selection is enabled by default RC4 SSL RSA WITH RC4 128 SHA a stream cipher with a key length of 128 bits A Secure Hash Algorithm SHA is used for authentication This selection is enabled by default 92 m m ai e V Cz o U lt U s e Option Description SSL TLS Server Certificate Status The Status field indicates whether a server certificate is installed To Filename display the status in the control console choose Web SSL TLS then Advanced SSL TLS Configuration Not installed No certificate is installed on the Rack PDU NOTE If you install a certificate by using FTP or SCP you must specify the correct location sec on the Rack PDU Generating The Rack PDU is generating a certificate because no valid certificate was installed Loading A certificate is being loaded activated on the Rack PDU Valid A valid certificate was installed to or generated by the Rack PDU If you install an invalid certificate the Rack PDU discards it and generates a valid one However a cert
23. address or DNS name of the server Switched Rack PDU Because the configuration information is part of the signature it cannot be exactly the same as the information you provided when creating the CA root certificate the information you provide in some of the fields must be different By default a server certificate is valid for 10 years from the current date and time but you can edit the Validity Period Note Start and Validity Period End fields 6 On the next screen review the summary of the certificate Scroll downward to view the certificate s unique serial number and fingerprints To make any changes to the information you provided click Back and revise the information m m am YN U V U Q C UJ Lo gt WY 140 The information for every certificate must be unique The configuration of a server certificate cannot be the same as the configuration of the CA root certificate The expiration Note date is not considered part of the unique configuration some other configuration information must also differ 7 The last screen verifies that the certificate has been created and instructs you on the next task to load the server certificate to the Switched Rack PDU It displays the location and name of the Server Certificate which has a p15 file extension and contains the Rack PDU private key and public root certificate Load the server certificate to the Rack PDU Perform these steps 1 On the Network m
24. and application modules by using the About System option in the System menu of the control console or in the Help menu of the Web interface or by using an SNMP GET to the MIB II sysDescr OID 170 Product Information Warranty and Service Limited warranty APC warrants the Switched Rack PDU to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser Warranty limitations Except as provided herein APC makes no warranties expressed or implied including warranties of merchantability and fitness for a particular purpose Some jurisdictions do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser Except as provided above in no event will APC be liable for direct indirect special incidental or consequential damages arising out of the use of this product even if advised of the possibility of such damage Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of
25. default values Access system information about the Rack PDU 23 m al MN U V U Q C im gt ua Web Interface How to Log On Overview You can use the DNS name or System IP address of the Switched Rack PDU for the URL address of the Web interface If you are using HTTPS SSL TSL as your access protocol your login credentials are compared with information in a server Note Certificate If the certificate was created with the APC Security Wizard when you log on you must use the same identifier for the Rack PDU as you specified for the common name in the certificate either the IP address or the DNS name Use your case sensitive user name and password settings to log on The default user name differs by account type apc for an Administrator device for a Device Manager readonly for a Read Only User The default password is apc for all three account types There is no default password for Outlet User accounts An Administrator must define the password and other account characteristics for an Outlet User See Outlet User Manager 24 m m C x c o Q c gt e See Web SSL Web SSL TLS in the control console to select enable and disable the protocols that control access to the Web interface and to define the Web server ports for the protocols For information about the Web page that appears when you log on to the Web interface see Summary Page
26. end to an available communications port on your computer Make sure no other application is using the port b Connect the other end to the serial port of the card or device 3 From the Start menu launch the Wizard application If the Network Management Card is not configured wait until it is detected by the Wizard If you are assigning basic TCP IP settings serially to a Network Management Card click Next gt to move to the next screen 4 Select Locally through the serial port and click Next gt 5 Enter the TCP IP settings System IP Subnet Mask and Default Gateway for the Network Management Card Then click Next gt 6 On the Transmit Current Settings Remotely screen if you check mark Start a Web browser when finished the default Web browser connects to the device that contains the Network Management Card after you transmit the card s settings 7 Click Finish to transmit the TCP IP settings If the IP address you entered is in use on the network the Wizard prompts you to enter an IP address that is not in use Enter a correct IP address and click Finish 8 If you selected Start a Web browser when finished in step 6 you can now configure other parameters through the Web interface of the card or device m m al MN U V U Q C im bam gt WY 152 How to Export Configuration Settings Retrieving and Exporting the ini File Summary of the procedure As an Administrator you can retriev
27. groups To do the following see Event Related Menus Access the event log Configure the actions to be taken based on the severity level of an event Configure SNMP Trap Receiver settings for sending event based traps Define who will receive e mail notifications and Syslog messages for events Test e mail settings To do the following see Data Menu Web Interface Only Access the data log Define the log interval how often data will be sampled and recorded for the data log 30 To do the following see Network Menu Configure new TCP IP settings for the Rack PDU Identify the Domain Name System DNS Server test its network connection and enable or disable DNS Reverse Lookup Event Logging which logs the domain name of the device associated with each event Define settings for FTP Telnet SSH the Web interface SNMP e mail and SSL TLS Configure the Rack PDU s Syslog message feature To do the following see System Menu Control Administrator and Device Manager access Manage Outlet User access Define the system Name Contact and Location values Set the date and time used by the Rack PDU Restart the Rack PDU Reset control console settings to default settings Define the URL addresses of the user links and APC logo link in the Web interface as described in Links menu Help menu When you click Help the Contents page for a
28. in the current editing session When you finish making changes on this page click Apply to confirm the changes 52 Event Related Menus Introduction Overview The Events menu provides access to the options that you use to do the following tasks Access the event log Define the actions to be taken when an event occurs based on the severity level of that event Event logging Syslog message notification SNMP trap notification E mail notification You can use only the Web interface to define which events will use which actions as described in Event Log and How to Note Configure Individual Events Define up to four SNMP trap receivers by NMS specific IP address or domain name for event notifications by SNMP traps Define up to four recipients for event notifications by e mail Menu options In the Web interface all of the events options are accessed through the Events menu m m al MN U V U Q C im Lo gt WY 53 m m A x UJ A U U lt Y s WY In the control console access the available events related options as follows Use the Email option in the Network menu to define the SMTP server and e mail recipients Use the SNMP option in the Network menu to define the SNMP trap receivers Use CTRL L to access the event log from any menu For information on the following topics use these links Event Log Event Actions Web I
29. is disabled by default Enable this feature unless you have no DNS server configured or have poor network performance because of heavy network traffic With Reverse DNS Lookup enabled when a network related event occurs reverse DNS lookup logs in the event log both the IP address and the domain name for the networked device associated with the event If no domain name entry exists for the device only its IP address is logged with the event Since domain names generally change much less frequently than IP addresses enabling reverse DNS lookup can improve the ability to identify addresses of networked devices that are causing events to occur Ping utility control console only Select this option available only in the control console to check the network connection by testing whether a defined IP address or domain name responds to the Ping network utility By default the IP address of the default gateway is used However you can use the IP address or domain name of any device known to be running on the network FTP Server Use the Access setting to enable or disable the FTP server The server is enabled by default 77 FTP transfers files without using encryption For higher security use Secure CoPy SCP for file transfers When you select and configure Secure SHell SSH SCP is enabled automatically To Note Configure SSH see Telnet SSH If you decide to use SCP for file transfer be sure to disable the FTP server
30. keyword value pairs section on line number in that section are ignored Configuration file warning A keyword entered at the beginning of the file i e Keyword found outside of a before any section headings is ignored section on line number Configuration file warning If the file is too large the Rack PDU stores and Configuration file exceeds processes what it can but ignores what it cannot maximum size Reduce the size of the file or divide it into two files and try uploading again 158 Messages in config ini A feature might not be supported for the device from which you retrieve the configuration settings or might not be supported for the device to which you export the configuration settings In this case the user configuration file contains under the section name for that feature a message stating that the feature is not supported No keywords and values are listed and that feature will not be configured on any device to which you export the user configuration file Errors generated by overridden values The Override keyword and its value will generate error messages in the event log when it blocks the exporting of values See Contents of the ini file for information about which values are overridden The overridden values are device specific and not appropriate to export to other Rack PDUs Therefore you can ignore these error messages To prevent these error messages from occurring you c
31. mode 74 Client ID setting 75 112 default gateway 73 74 defining settings 73 Domain Name setting 74 112 Ethernet Port Speed setting 112 Host Name setting 74 112 180 On Retry Failure setting 76 Port Speed setting 75 Retry Then Fail setting 75 setting port assignments for extra security 120 subnet mask 73 74 system IP address 73 74 User Class setting 75 112 Vendor Class setting 75 112 Telnet SSH Access option 80 host key fingerprints displaying 84 modifying the Port settings 81 option in Network menu 78 selecting the protocol mode 80 SSH host key file name 83 SSH host key file status 83 SSH Port option 81 SSHv1 Encryption Algorithms 82 SSHv2 Encryption Algorithms 82 Telnet Port option 81 Testing the network connection to the DNS server 76 Time Zone 106 Timeout setting for RADIUS 102 To address 66 Tools menu 107 Delete SSH Host Keys and SSL Certificates 107 File Transfer 107 Reboot 107 Reset Only TCP IP to Defaults 107 Reset to Defaults 107 Reset to Defaults Except TCP IP 107 Upload a user configuration file 107 Transport Layer Security TLS 124 Trap Generation 63 Trap Receivers 63 Traps 63 2 Q ai U V aa U UV te Y gt N U Up Time control console main screen 19 Web interface 27 Update Interval 106 Upgrading firmware without using a utility 162 Upload a user configuration file 107 URL address formats 26 User access identification control console interface 19 User Class setting 7
32. on the last request of the sequence and immediately releases that lease This prevents the DHCP server from reserving the IP Address associated with its invalid offer Q If a DHCP server responds with an invalid offer e g without the m m al YN U V U Q C im Lo gt WY For more information on what a valid response requires see DHCP response options 111 2 Q ai U V aa U UV te Y gt N DHCP Configuration Settings Switched Rack PDU settings The TCP IP option in the Network menu of the Web interface and control console accesses the network settings for the Switched Rack PDU Three settings Ethernet Port Speed Host Name and Domain Name are available regardless of the TCP IP option s Boot mode selection and three settings Vendor Class Client ID and User Class are available for any Boot mode selection except Manual When Boot mode is set to DHCP amp BOOTP two options are available After IP Assignment in the control console or Remain in DHCP amp BOOTP mode after accepting TCP IP settings in the Web interface By default this option switches Boot mode to the selection that reflects the server that provided the TCP IP settings DHCP Only or BOOTP Only DHCP Cookie Is in the control console or Require vendor specific cookie to accept DHCP Address in the Web interface By default this option requires that the DHCP responses include the APC cookie in order to be valid
33. option On a busy remote SMTP server the time out may prevent some e mail from being sent and with this option the Rack PDU tries to send the e mail only once When the recipient uses the SMTP server provided with the Rack PDU the Recipient s setting has no effect Generation Enables by default or disables sending e mail to the recipient Format Selects the format used for e mail messages Short Identifies only the event that occurred For example Switched Rack PDU Overload threshold exceeded Long Includes information about the Rack PDU and the event For example Name TestLab Location Building 3 Contact DonAdams http 139 225 6 133 Switched Rack PDU Ser WS0131005294 Date 6 25 2004 Time 16 09 48 Code OxOFOE Warning Switched Rack PDU Overload threshold exceeded 67 How to Configure Individual Events Event List page The Actions option in the Events menu opens the Event Action Configuration page on the Web interface Use the Details button in this page to access a complete list of the events that can be reported by your Switched Rack PDU Modifying events on the Configure Event Action by Severity Level page will override any changes you have made to individual Note events on the Details page Each event is identified by its unique code its description and its assigned severity level For example Code Description Severity 0x0002 System Warmstart Severe OxOFOA Switc
34. server The shared secret between the primary RADIUS server and the Rack PDU Secondary Server The server name or IP address of the secondary RADIUS server Secondary Server Secret The shared secret between the secondary RADIUS server and the Rack PDU Timeout The time in seconds that the Rack PDU waits for a response from the RADIUS server 102 m m C x V c o Q c gt e Configuring the RADIUS server You must configure your RADIUS server to work with the Rack PDU The following example shows how to configure a RADIUS server for use with a Rack PDU APC supports authentication and authorization of users by various RADIUS servers and does not recommend a specific RADIUS server 1 Add the IP address of the Rack PDU to the RADIUS server client list file 2 The users must be configured with a Service Type attribute If no Service Type attribute is configured the user will have read only access on the Web interface only There are two acceptable values for Service Type Administrative User 6 which gives the user Administrator permissions or Login User 1 which gives the user Device Manager permissions The following examples may differ somewhat from the required content or format of your specific RADIUS server eS See your RADIUS server documentation for information about the RADIUS users file See also Example RADIUS users file UPSAdmin Auth Type
35. the Certificate Authority import that certificate Importing the certificate combines the p15 file containing the private key and the file containing the signed certificate from the external Certificate Authority The output file is a new encrypted server certificate file with a p15 extension Load the server certificate onto the Switched Rack PDU For each Switched Rack PDU that requires a server certificate repeat the tasks that create and load the server certificate The procedure Create the Certificate Signing Request CSR Perform these steps Click Next to move from screen to screen 1 If the APC Security Wizard is not already installed on your computer install it by running the installation program APC Security Wizard exe from the APC Rack PDU Utility CD that came with your Rack PDU m m am YN U V U Q C UJ bam gt WY 142 m m ai e V Cz o U lt U s e On the Windows Start menu select Programs then APC Security Wizard to start the Wizard program On the screen labeled Step 1 select Certificate Request as the type of file to create Enter a name for the file that will contain the Switched Rack PDU s private key The file name must have a p15 extension By default the file will be created in the installation folder C Program Files American Power Conversion APC Security Wizard On the screen labeled Step 2 provide the information to configur
36. the real time clock for the Rack PDU with a Network Time Protocol NTP server Reset the Rack PDU to default settings Define the URL links available in the Web interface configurable through the Web interface only Access hardware and firmware information about the Rack PDU control console only Download configuration files control console only Only an Administrator has access to the System menu Note m al MN U V U Q C im gt ua 96 m m A x UJ A U U lt Y s WY Menu options Unless noted the following menu options are available in the control console and Web interface User Manager Outlet User Manager RADIUS Identification Date amp Time Tools Links Web interface Modem not supported About System Q The About System option is a Help menu option in the Web interface Note 97 m m C x V c o Q c gt e Option Settings User Manager Use this option Web interface to define access values shared by the control console and Setting Definition Values affecting all users Auto Logout The number of minutes 3 by default before a user is automatically logged off because of inactivity Separate values for Administrator Device Manager and Read Only User User Name The case sensitive name maximum of 10 characters used to log on at the control console or Web interface
37. value for Reboot Duration and then apply power to each outlet according to its value for Power On Delay T If an outlet group is selected the configured delays and reboot duration of the lowest numbered outlet for a local outlet group or of the global outlet for a global outlet group that is initiating the action 50 m m ai e V Cz o U lt U s e How to schedule an outlet event 1 From the menus of the Web interface select Switched Rack PDU and then Scheduling 2 On the Outlet Scheduling page select how often the event will occur Daily Weekly or One Time Q If you select Weekly you can choose to have the event occur once every week or once every two four or eight weeks Note 3 On the scheduling page in the Name of event text box replace the default name Outlet Event with a name that will identify your new event 4 Use the drop down lists to select the type of event and when it will occur The date format for one time events is mm dd and the time format for all events is hh mm with the two digit hour Note specified in 24 hour time An event that is scheduled daily or at one of the intervals available in the Weekly selection continues to occur at the scheduled interval until the event is deleted or disabled You can schedule a one time event to occur only on a date within 12 months of the date on which you perform the scheduling For example on June 4 2004
38. 2 0 x of the AOS firmware module already you can upgrade directly to version 2 1 0 or a later version To use XMODEM to upgrade the firmware for a single Switched Rack PDU that is not on the network 1 Obtain the individual firmware modules the AOS module and the application module from the support section of the APC web site www apc com tools download m m ai e V Cz o U lt U s 168 m m ai e V Cz o U lt U s Select a serial port at the local computer and disable any service which uses that port Connect the smart signaling cable that came with the Rack PDU to the selected port and to the serial port at the Rack PDU Run a terminal program such as HyperTerminal and configure the selected port for 9600 bps 8 data bits no parity 1 stop bit and no flow control and save the changes 5 Press ENTER to display the User Name prompt 10 Enter your Administrator user name and password The default for both is apc Start an XMODEM transfer a Select option 3 System b Select option 4 File Transfer c Select option 2 XMODEM d Type Yes at the prompt to continue with the transfer Select the appropriate baud rate A higher baud rate causes faster firmware upgrades Also change the terminal program s baud rate to match the one you selected and press ENTER From the terminal program s menu select the binary AOS file to transfer v
39. 264 bin apc hw02 app 266 bin 2 Open an FTP client session C apc gt ftp 3 Type open and the Switched Rack PDU s IP address and press ENTER If the Port setting for FTP Server in the Network menu has changed from its default of 21 you must use the non default value in the FTP command a For some FTP clients use a colon to add the port number to the end of the IP address b For Windows FTP clients separate the port number from the IP address by a space For example if the Rack PDU s FTP Server Port setting has been changed from its default of 21 such as to m m ai e V Cz o U lt U s e 166 m m ai e V Cz o U lt U s 21000 you would use the following command for a Windows FTP client transferring a file to a Rack PDU with an IP address of 150 250 6 10 ftp open 150 250 6 10 21000 4 Log on using the Administrator user name and password apc is the default for both 5 Upgrade the AOS For example ftp bin ftp put apo hw02 aos 264 bin 6 When FTP confirms the transfer type Quit to close the session 7 Wait 20 seconds and then repeat step 2 through step 6 but in step 5 use the application module file name instead of the AOS module Instructions for using SCP To use Secure CoPy SCP to upgrade the firmware for one Rack PDU 1 Identify and locate the firmware modules described in the preceding instructions for FTP 2 Use an SCP command line to transfer the AO
40. 5 112 User configuration files contents 154 customizing 156 exporting system time separately 156 overriding device specific values 154 retrieving and exporting 153 system event and error messages 158 using the APC utility to retrieve and transfer the fies 155 168 User Manager defining access values and authentication 98 User Name change immediately for security 119 default for each type of account 24 User Manager access 98 V Vendor Class setting 75 112 Vendor Specific Information Cookies 114 W WAP 95 Web interface enable or disable protocols 90 181 logging on 24 Modifying the Port setting forFTP 78 forHTTP 91 for HTTPS 91 forSSH 81 for Telnet 81 Status 27 Up Time 27 URL address formats 26 Wireless Access Protocol WAP 95 APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information www apc com support Global support searching APC Knowledge Base and using e support Contact an APC Customer Support center by telephone or e mail Regional centers Direct InfraStruXure Customer 1 877 537 0607 toll free Support Line APC headquarters U S
41. Common Name fields are required the other fields are optional For the Common Name field enter an identifying name of your company or agency use only alphanumeric characters with no spaces By default a CA root certificate is valid for 10 years from the current date and time but you can edit the Validity Period Note Start and Validity Period End fields On the next screen review the summary of the certificate Scroll downward to view the certificate s unique serial number and fingerprints To make any changes to the information you provided click Back and revise the information 138 m m C x V c o Q c gt e Q The certificate s subject information and the certificate s issuer information should be identical Note 7 The last screen verifies that the certificate has been created and instructs you on the next tasks This screen displays the location and name of the p15 file that you will use to sign the server certificates This screen also displays the location and name of the crt file which is the CA root certificate that you will load into the browser of each user who needs to access the Rack PDU Load the CA root certificate to your browser Load the crt file to the browser of each user who needs to access the Rack PDU See the help system of the browser for information on how to load the crt file into the browser s certificate store cache Following is See also summ
42. Date Time section as a separate ini file The time necessary to export a large file would cause the configured time to be significantly inaccurate For greater accuracy if the Switched Rack PDUs receiving the file can access a Network Time Protocol NTP Server set the value for the NTPEnable keyword as follows NTPEnable enabled Add comments about changes that you made The first printable character of a comment line must be a semicolon 2 Copy the customized file to another file name in the same folder The copy which you will export to other Rack PDUs can have any file name up to 64 characters and must have the ini file suffix Retain the original customized file for future use The file that you retain is the only record of your comments They are removed automatically from the file that you export 156 m m C x V c o Q c gt e Exporting the file to a single Rack PDU To export the ini file to another Switched Rack PDU use any of the file transfer protocols supported by Switched Rack PDUs including FTP FTP Client SCP and TFTP The following example uses FTP 1 From the folder containing the customized ini file and its copy use FTP to log in to the Rack PDU to which you are exporting the ini file For example ftp open 158 165 4 135 2 Export the copy of the customized ini file The receiving Rack PDU accepts any file name that has the ini suffix is no more
43. For more information about the APC cookie see DHCP response options 112 When Boot mode is set to DHCP Only two options are available DHCP Cookie Is in the control console or Require vendor specific cookie to accept DHCP Address in the Web interface By default this option requires that the DHCP responses include the APC cookie in order to be valid For more information about the APC cookie see DHCP response options Retry Then Stop in the control console or Maximum of Retries in the Web interface This option sets the number of times the Switched Rack PDU will repeat the DHCP request if it does not receive a valid response By default the number of retries is 0 which sets the Switched Rack PDU to continue repeating the DHCP request indefinitely E m A aa U t v c Y a gt V 113 DHCP response options Each valid DHCP response contains options that provide the TCP IP settings that the Switched Rack PDU needs to operate on a network and other information that affects the operation of the Rack PDU The Rack PDU uses the Vendor Specific Information option option 43 in a DHCP response to determine whether the DHCP response is valid Vendor Specific Information option 43 The Vendor Specific Information option contains up to two APC specific options encapsulated in a Tag Len Data format the APC Cookie and the Boot Mode Transition APC Cookie Tag 1 Len 4 Data 1APC Opt
44. IP address on each of those Rack PDUs NOTE A Maximum of four devices can be configured with the same Multicast name and Multicast IP address How to create a local outlet group Web interface 1 From the Outlets menu in the Web interface select Outlet Groups 2 Make sure outlet groups are enabled See Enable creation of outlet groups 3 Click Create Local Outlet Group 4 Under Configure Local Outlet Group select each outlet that will be in the group You must select at least two outlets 37 m m C x V c o Q c gt e How to create multiple global outlet groups Web interface To set up multiple global outlet groups that link to outlet groups on other Switched Rack PDUs 1 From the Outlets menu in the Web interface select Outlet Groups 2 Make sure outlet groups are enabled and that the Multicast parameters name and IP address are the same for all Rack PDUs to be linked See How to enable outlet groups 3 Click Create Global Outlet Groups 4 For each global outlet group you want to create select an outlet by clicking on its check box Then click Apply For example select five outlets to create five outlet groups each consisting of one global outlet 5 To add outlets to any of the global outlet groups you created see How to edit or delete an outlet group How to edit or delete an outlet group 1 From the Outlets menu in the Web interface select Outlet Gr
45. It is not disabled by enabling SSH 123 Secure Sockets Layer SSL Transport Layer Security TLS For secure Web communication you enable Secure Sockets Layer SSL and Transport Layer Security TLS by selecting HTTPS SSL TLS as the protocol mode to use for access to the Web interface of the Switched Rack PDU Hypertext Transfer Protocol over Secure Sockets Layer HTTPS is a Web protocol that encrypts and decrypts page requests from the user and pages that are returned by the web server to the user Originally developed by Netscape it has become an internet standard supported by most Web browsers The Switched Rack PDU supports SSL version 3 0 and TLS version 1 0 Most browsers let you select the version of SSL to enable When SSL is enabled your browser displays the lock icon e usually at the bottom of the screen SSL uses a digital certificate to enable the browser to authenticate the server in this case the Switched Rack PDU The browser verifies the following The format of the server certificate is correct The server certificate s expiration date and time has not passed The DNS name or IP address specified when a user logs on matches the common name in the server certificate The server certificate is signed by a trusted certifying authority Each major browser manufacturer distributes CA root certificates of the commercial Certificate Authorities in the certificate store cache of its browser so that it
46. Outlet User Account User Name The user name for logging on to this user or account Password Case sensitive password for this user Edit Outlet User Account account Description Identification of the outlet user Delete Outlet User Account Enter the user name of the outlet user account to delete Disable Outlet User Account Enter the user name of the outlet user account to disable Enable Outlet User Account Enter the user name of the outlet user account to enable Edit Users Outlet Access Select the outlets to which users have access 1 Enter the user name of the outlet user account to modify 2 Select the numbers of the outlets to which the outlet user will have access To add access to an outlet enter an outlet number and press ENTER Enter a space character when you finish adding access to outlets To remove access to an outlet enter an outlet number preceded by a minus sign and press ENTER Enter a space character when you finish removing access to outlets List Outlet Users Accounts Display outlet user name status description and outlet access for each outlet user account m m C x V c o Q c gt e 100 RADIUS RADIUS Remote Authentication Dial In User Service is an authentication authorization and accounting service APC supports the authentication and authorization functions of RADIUS Use this option to centrally administer remote acc
47. S firmware module to the Rack PDU The following example assumes a Rack PDU IP address of 158 205 6 185 and an AOS module of apc hw02 aos 264 bin scp apc hw02 aos 264 bin apc8158 205 6 185 apc hwO2 aos 264 bin 3 Use a similar SCP command line with the name of the application module instead of the AOS module to transfer the application module to the Rack PDU How to upgrade multiple Rack PDUs Export configuration settings You can create batch files and use an APC utility to retrieve configuration settings from multiple Rack PDUs and export them to other Rack PDUs 167 See Release Notes ini File Utility version 1 0 doc en ininotes pdf on the APC Rack PDU Utility CD that See also Came with your Rack PDU Use FTP or SCP to upgrade multiple Rack PDUs To upgrade multiple Switched Rack PDUs using an FTP client or using SCP write a script which automatically performs the procedure For FTP use the steps in Use FTP or SCP to upgrade one Rack PDU Use XMODEM to upgrade one Rack PDU directly from firmware version 1 x x to 2 1 0 or later The upgrade Q You cannot upgrade the AOS firmware module of any APC device Note attempt will fail To upgrade the AOS firmware module of an APC device from version 1 x x to 2 1 0 or later first upgrade the module to the latest available version 2 0 x AOS firmware module Then upgrade it again this time from version 2 0 x to the 2 x x version you want If your APC device is running a
48. Supported W eb browsers As your browser you can use Microsoft Internet Explorer IE 5 0 and higher or Netscape 4 0 8 and higher except Netscape 6 x to access the Rack PDU through its Web interface Other commonly available browsers also may work but have not been fully tested by APC Data verification the event log and the data log require that you enable the following for your Web browser JavaScript e Java Cookies In addition the Rack PDU cannot work with a proxy server Therefore before you can use a Web browser to access its Web interface you must do one of the following Configure the Web browser to disable the use of a proxy server for the Rack PDU Configure the proxy server so that it does not proxy the specific IP address of the Rack PDU 25 m m ai e V Cz o U lt U s e URL address formats Type the Rack PDU s DNS name or IP address in the Web browser s URL address field and press ENTER Except when you specify a non default web server port in Internet Explorer http or https is automatically added by the browser Internet Explorer only someone is logged onto the Web interface or control console If the error No Response Netscape or This page cannot be displayed Internet Explorer occurs Web access may be disabled or the Rack PDU may use a non default Web server port that you did not specify correctly in the address For Internet Explorer you must type
49. Switched Rack PDU firmware A global outlet of one outlet group must have the same physical outlet number as the global outlet of any other outlet group to which it links Even if InfraStruXure Manager is not used with your system you must enable the ISX Protocol for each Switched Rack PDU to link global outlet groups across Switched Rack PDUs To enable the ISX Protocol see ISX Protocol control console only To create and configure outlet groups you must use the Web interface or export configuration file ini file settings from a configured Switched Rack PDU The control console lets you display whether an outlet is a member of an outlet group and to apply control actions to an outlet group but does not let you set up or configure an outlet group m m am MN U V U Q C UJ bam gt WY 36 2 Q ai U V aa U UV te Y gt N How to enable outlet groups From the Outlets menu in the Web interface select Outlet Groups configure the following parameters and click Apply Enable creation of outlet groups Parameter Description Device Level Outlet Group To create an outlet group you must enable this parameter It is disabled by default Enable support for global outlet groups linked groups Parameter Description Multicast Name To link outlet groups on multiple Switched Rack PDUs you must Multicast IP define the same Multicast name and Multicast
50. Use the Port setting to identify the TCP IP port that the FTP server uses for communications with the Rack PDU The default Port setting is 21 You can change the Port setting to any unused port from 5000 to 32768 to enhance the protection provided by User Name and Password settings You must then use a colon in the command line to specify the non default port For example for a port number of 5000 and a Rack PDU IP address of 159 215 12 114 you would use this command ftp 159 215 12 114 5000 To access a text version of the Rack PDU s event or data log see How to use FTP or SCP to retrieve a log file Telnet SSH Use the Telnet SSH option to perform the following tasks Enable or disable Telnet or the Secure SHell SSH protocol for remote control console access While SSH is enabled you cannot use Telnet to access the control console Enabling SSH enables SCP automatically When SSH is enabled and its port and encryption ciphers configured no further configuration is required to use Note SCP SCP uses the same configuration as SSH m m ai e Y Cz o U lt U s e 78 Do not enable both versions of SSH unless you require that both be activated at the same time Security protocols use extensive processing power Linux and other UNIX platforms include an SSH client as part of their installation but Microsoft Windows operating systems do not SSH clients are available from various ven
51. WY p A Remote access to the control console You can access the control console through Telnet or Secure SHell SSH depending on which is enabled An Administrator can enable these access methods through the Telnet SSH option of the Network menu By default Telnet is enabled Enabling SSH automatically disables Telnet Telnet for basic access Telnet provides the basic security of authentication by user name and password but not the high security benefits of encryption To use Telnet to access the control console from any computer on the same subnet 1 At a command prompt type telnet and the System IP address for the Rack PDU when the PDU uses the default Telnet port of 23 and then press ENTER For example telnet 139 225 6 133 and 32768 you need to include a colon or a space depending on your Telnet client after the IP address and then enter the port number Q If the PDU uses a non default port number between 5000 Note 2 Enter the user name and password by default apc and apc for an Administrator or device and apc for a Device Manager SSH for high security access If you use the high security of SSL for the Web interface use Secure SHell SSH for access to the control console SSH encrypts user names passwords and transmitted data The interface user accounts and user access rights are the same whether you access the control console through SSH or Telnet but to use SSH you must first configur
52. ables by default or disables SNMP When SNMP is enabled the Access Control settings allow you to control how each of the four available SNMP channels is used To define up to four NMSs to serve as trap receivers see Trap Receiver settings To use SNMP to manage a Switched Rack PDU see the eS PowerNet SNMP Management Information Base MIB Reference Guide doc en mibguide pdf on the APC Rack See also BDU Utility CD that came with your Rack PDU Setting Definition Community Defines the password maximum of 15 characters that an NMS defined Name by the NMS IP Domain Name setting uses to access the channel m m ai e Y Cz o U lt U s e 84 Setting Definition NMS IP Limits access to the NMS specified by a domain name or to the NMSs Domain specified by the format used for the IP address Name A domain name allows only the NMS at that location to have access 159 215 12 1 allows only the NMS with that IP address to have access 159 215 12 255 allows access for any NMS on the 159 215 12 segment 159 215 255 255 allows access for any NMS on the 159 215 segment 159 255 255 255 allows access for any NMS on the 159 segment 0 0 0 0 or 255 255 255 255 allows access for any NMS Access Selects how the NMS defined by the NMS IP setting can use the channel Type when that NMS uses the correct value for Community Name Read The NMS can use GETSs at any time but
53. an SNMP browser and the APC PowerNet Management Information Base MIB to manage your Rack PDU Switched Rack PDUs have these additional features Current monitoring per phase or bank Configurable alarm thresholds that provide network and visual alarms to help avoid overloaded circuits Independent outlet control Configurable power delays 24 independent outlet user accounts m m ai e V Cz o U lt U gt e Four levels of user access accounts Administrator Device Manager Read Only User and Outlet User Event and data logging the event log is accessible by Telnet Secure CoPy SCP File Transfer Protocol FTP serial connection or Web browser using HTTPS access with SSL or using HTTP access The data log is accessible by Web Browser SCP and FTP E mail notifications for Rack PDU and system events SNMP traps Syslog messages and e mail notifications based on the severity level of Rack PDU and system events A selection of security protocols for authentication and encryption The Rack PDU does not provide power protection Therefore APC does not recommend plugging a unit directly into any Note Unprotected power source such as a wall outlet Initial setup You must define the following three TCP IP settings for the Switched Rack PDU before it can operate on the network IP address of the Rack PDU e Subnet mask IP address of the default gateway To configure the TCP IP s
54. an delete the lines that contain the Override keyword and the lines that contain the values that they override Do not delete or change the line containing the section heading m m C x c o Q c gt e 159 E m A aa U t v c Y ad gt V Using the APC Device IP Configuration Wizard On Windows operating systems instead of using the preceding procedure for exporting ini files you can choose to update the basic TCP IP settings of Rack PDUs by using the APC Device IP Configuration Wizard See APC Device IP Configuration Wizard for a detailed description of how to discover and configure unconfigured Switched Rack PDUs remotely over your TCP IP network or configure or reconfigure a Switched Rack PDU through a direct connection from the serial port of your computer to the Switched Rack PDU 160 File Transfers Introduction Overview The Switched Rack PDU automatically recognizes binary firmware files Each of these files contains a header and one or more Cyclical Redundancy Checks CRCs to ensure that the data contained in the file is not corrupted before or during the transfer operation When new firmware is transmitted to the Rack PDU the program code is updated and new features become available This chapter describes how to transfer firmware files to Switched Rack PDUs To transfer a firmware file to a Rack PDU see Upgrading Firmware Methods and Tools To v
55. and then edit the actions that will occur for an individual event as described in How to Configure Individual Events Click Hide Details to return to the Actions option 60 m m C x V c o Q c gt e Modifying events on the Configure Event Action by Severity Level page overrides any changes you made to individual events Note on the Details page Severity levels Except for some System embedded management card events that do not have a severity level events are assigned a default severity level based on their seriousness Informational Indicates an event that requires no action such as a notification of a return from an abnormal condition Warning Indicates an event that may need to be addressed if the condition continues but does not require immediate attention Severe Indicates an event that requires immediate attention Unless resolved severe Device and System events can cause incorrect operation of the Rack PDU or its embedded management card Event log action You can disable the recording of events in the event log By default all events are recorded even events that have no severity level assigned Even if you disable the event log action for all severity levels System embedded management card events that have no Note Severity level assigned will still be logged For more information about this log see Event Log 61 m A aa U t v c Y a gt V Sys
56. ary of the procedure for Microsoft Internet Explorer 1 Select Tools then Internet Options from the menu bar 2 On the Content tab in the Internet Options dialog box click Certificates and then Import 3 The Certificate Import Wizard will guide you through the rest of the procedure The file type to select is X 509 and the CA Public Root Certificate is the crt file created in the procedure Create a Root Certificate amp Server Certificates 139 Create an SSL Server User Certificate Perform these steps Click Next to move from screen to screen 1 On the Windows Start menu select Programs then APC Security Wizard to start the Wizard program 2 On the screen labeled Step 1 select SSL Server Certificate as the type of file to create 3 Enter a name for the file that will contain the server certificate and the private key The file name must have a p15 extension By default the file will be created in the installation folder C Program Files American Power Conversion APC Security Wizard 4 Click the Browse button and select the CA root certificate created in the procedure Create a Root Certificate amp Server Certificates The CA Root Certificate is used to sign the Server User Certificate being generated 5 On the screen labeled Step 2 provide the information to configure the server certificate The Country and Common Name fields are required the other fields are optional For the Common Name field enter the IP
57. as specified as the Common Name use the DNS name to log on When you log on if you do not use the IP address or DNS name that was specified for the certificate authentication fails and you receive an error message asking if you want to continue Organization O Organizational Unit OU and Locality Country The name organizational unit and location of the organization that is using the server certificate If the server certificate was generated by default by the Rack PDU the Organizational Unit OU field displays Internally Generated Certificate Serial Number The serial number of the server certificate Issued By Common Name CN The Common Name as specified in the CA root certificate except if the server certificate was generated by default by the Rack PDU For a default server certificate the Common Name CN field displays the Rack PDU s serial number Organization O and Organizational Unit OU The name and organizational unit of the organization that issued the server certificate If the server certificate was generated by default by the Rack PDU the Organizational Unit OU field displays Internally Generated Certificate Validity Issued on The date and time at which the certificate was issued Expires on The date and time at which the certificate expires 94 m m C x V c o Q c gt e Parameter Description Fingerprints Each fingerp
58. b Define an HTTP or HTTPS link to a Web site or IP address interface http www apcc com links the outlet to the home page of the APC Web site http 158 205 7 201 links the outlet to the Web interface of the Switched Rack PDU at the IP address 158 205 7 201 enabling you to log on to that interface if you have the appropriate access NOTE If the outlet is a member of an outlet group the only link that is used is the link configured for the global outlet or for a local outlet group the link configured for the lowest numbered outlet of a local outlet group You can configure a link for another outlet in an outlet group but that link will be available to use only when that outlet is no longer a member of an outlet group 44 m m C x V c o Q c gt e W eb Interface To configure the outlet settings or outlet names select Configuration on the Outlets menu and click the Configure button in the Outlet Settings section or in the Outlet Name Configuration section Configure outlet settings in the top section of the next screen Select the check boxes next to the numbers of the outlets you want to modify or select the All Outlets check box Enter values for Power On Delay Power Off Delay or Reboot Duration and click the Apply button immediately below the list Configure outlet names and links in the bottom section of the next screen Select the check boxes next to the number
59. can compare the signature on the server certificate to the signature on a CA root certificate m m al V Cz o U te U s e 124 m m C x c o Q c gt e You can use the APC Security Wizard provided on the APC Rack Power Distribution Unit Utility CD that came with your Rack PDU to create a certificate signing request to an external Certificate Authority or if you do not want to use an existing Certificate Authority you can create an APC root certificate to upload to a browser s certificate store cache You can also use the Wizard to create a server certificate to upload to the Rack PDU See Creating and Installing Digital Certificates for a summary of how these certificates are used To create certificates and certificate requests see Create a Root Certificate amp Server Certificates and Create a Server Certificate See also and Signing Request SSL also uses various algorithms and encryption ciphers to authenticate the server encrypt data and ensure the integrity of the data i e that it has not been intercepted and sent by another server See CipherSuite to select which authentication and encryption algorithms to use Web browsers cache save Web pages that you recently accessed and allow you to return to those pages without re entering your user name and password Always close your browser session before you leave your computer unattended Note 125 Creati
60. ck PDU During rebooting if no server certificate exists on the Rack PDU the Rack PDU generates a default server certificate that is self signed but that you cannot configure This method has the following advantages and disadvantages Advantages Before they are transmitted the user name and password for Rack PDU access and all data to and from the Rack PDU are encrypted You can use this default server certificate to provide encryption based security while you are setting up either of the other two digital certificate options or you can continue to use it for the benefits of encryption that SSL provides Disadvantages The Rack PDU takes up to 5 minutes to create this certificate and the Web interface is not available during that time This delay occurs the first time you log on after you enable SSL This method does not include the browser based authentication provided by a CA certificate a certificate signed by a Certificate Authority as Methods 2 and 3 provide There is no CA Certificate cached in the browser Therefore whenever you log on to the Rack PDU the browser generates a security alert indicating that a certificate signed by a trusted authority is not available and asking if you want to proceed The default server certificate on the Rack PDU has the Rack PDU s serial number in place of a valid common name the DNS name or the IP address of the Rack PDU Therefore although the Rack 127
61. d To confirm that the server certificate is signed by a trusted signing authority the browser compares the signature of the server certificate with the signature in the root certificate cached in the browser An expiration date confirms whether the server certificate is current This method has the following advantages and disadvantages Advantages Before they are transmitted the user name and password for Rack PDU access and all data to and from the Rack PDU are encrypted The length of the public key RSA key that is used for encryption when setting up an SSL session is 1024 bits providing more complex encryption and consequently a higher level of security than the public key used in Method 1 This longer encryption key is also used in Method 3 m m am YN U V U Q C UJ bam gt WY 129 2 Q ai U V aa U UV te Y gt N The server certificate that you upload to the Rack PDU enables SSL to authenticate that data are being received from and sent to the correct Rack PDU This provides an extra level of security beyond the encryption of the user name password and transmitted data The root certificate that you install to the browser enables the browser to authenticate the Rack PDU s server certificate to provide additional protection from unauthorized access Disadvantage Because the certificates do not have the digital signature of a commercial Certificate Au
62. d port between 5000 and 32768 to enhance the protection provided by User Name and Password settings Then according to the requirements of your Telnet client program you must use either a colon or a space in the command line to specify the non default port number For example for a port number of 5000 and a Rack PDU IP address of 159 215 12 114 your Telnet client would require one or the other of the following commands telnet 159 215 12 114 5000 telnet 159 215 12 114 5000 SSH Port Identifies the TCP IP port used for communications by the Secure SHell SSH protocol with the Rack PDU The default is 22 You can change the Port setting to the number of any unused port between 5000 and 32768 to enhance the protection provided by User Name and Password settings See the documentation for your SSH client for information on the command line format required to specify a non default port number when starting SSH 81 m m C x V c o Q c gt e Option Description SSH Server Configuration SSHv1 Enables or disables DES and displays the status always enabled of Encryption Blowfish two encryption algorithms block ciphers compatible with Algorithms SSH version 1 clients DES The key length is 56 bits Blowfish The key length is 128 bits You cannot disable this algorithm NOTE Not all SSH clients can use every algorithm If your SSH client cannot use Blowfish y
63. dors To use SSH you must have an SSH client installed Most Note Configure the port settings for Telnet and SSH Select one or more data encryption algorithms for SSH version 1 SSH version 2 or both In the Web interface specify a host key file previously created with the APC Security Wizard and load it to the Rack PDU From a command line interface such as the command prompt on Windows operating systems you can use FTP or Secure CoPy SCP to transfer the host key file You must D transfer the file to location sec on the Rack PDU If you do not specify a host key file the Switched Rack PDU Note generates an RSA host key of 768 bits instead of the 1024 bit RSA host key that the Wizard creates The Rack PDU can take up to 5 minutes to create this host key and SSH is not accessible during that time Display the fingerprint of the SSH host key for SSH versions 1 and 2 Most SSH clients display the fingerprint at the start of a session Compare the fingerprint displayed by the client to the fingerprint that you recorded from the Web interface or control console of the Rack PDU m m ai e V Cz o U lt U s e 79 when logging on to the control console of the Rack PDU Although the delay is not long it can be mistaken for a problem because there is no explanatory message If you are using SSH version 2 expect a noticeable delay Note Option Description Telnet SSH Netw
64. e the values used for the MIB II sysName sysContact and sysLocation Object Identifications OIDs For more information about the MIB II OIDs see the PowerNet eS SNMP Management Information Base MIB Reference Guide doc en mibguide pdf provided on the APC Rack Power Distribution Unit Utility CD that came with your Rack PDU See also Date amp Time Use this option to set the date and time used by the Switched Rack PDU The option displays the current settings and allows you to change those settings manually or through a Network Time Protocol NTP Server Set Manually Use this option in the Web interface or Manual in the control console to set Date and Time for the Switched Rack PDU An Apply Local Computer Time to System option which is available in the Web interface only sets these values to match the date and time settings of the computer you are using to access the Web interface Note m m C x V c o Q c gt e 105 m m C x V c o Q c gt e Synchronize with Network Time Protocol NTP Server Use this option on the Web interface or Network Time Protocol NTP on the control console to have an NTP Server automatically update the Date and Time settings for the Switched Rack PDU disable the NTP Server updates In the Web interface use the Q In the control console use the NTP Client option to enable or Note Set Manually option The updates are disab
65. e SSH and have an SSH client program installed on your computer m m al V Cz o U te U s e m am MN U V Ee U Q C UJ gt V Local access to the control console You can use a local computer that connects to the Rack PDU through the serial port on the front panel of the unit 1 Select a serial port at the local computer and disable any service which uses that port 2 Use the supplied serial cable 940 0144 to connect the selected port to the serial port on the front panel of the Rack PDU 3 Run a terminal program such as HyperTerminal and configure the selected port for 9600 bps 8 data bits no parity 1 stop bit and no flow control Save the changes 4 Press ENTER repeatedly if necessary to display the User Name prompt m m A x UJ A U U lt Y s WY Main Screen Example main screen The main screen that is displayed when you log on to the control console of a Rack PDU 20m Name apc Password American Power Conversion Network Management Card AOS v2 6 4 served Rack PDU APP v2 6 6 c Copyright 2002 All Rights Re Name MS3 Test Unit Contact Bill Cooper Location Testing Lab Up Time 0 Days 0 Hours 43 Mi Switched Rack PDU Communication Date 6 25 2004 Time 10 16 58 User Administrator nutes Stat P N At Established Control Console 1 Device Manager 2 Network 3 System 4 Lo
66. e a dynamically generated ini file of a Switched Rack PDU s current configuration and export that file to another Switched Rack PDU or to multiple Switched Rack PDUs 1 Configure a Switched Rack PDU to have the settings you want to export 2 Retrieve the ini file from that Rack PDU 3 Customize the ini file to change at least the TCP IP settings and make a copy to export 4 Use any of the file transfer protocols supported by the Switched Rack PDU to transfer the copied file to one or more additional Rack PDUs To transfer the file to multiple Rack PDUs simultaneously write an FTP or SCP script that repeats the steps for transferring the file to a single Rack PDU 5 Each receiving Switched Rack PDU stores the file temporarily in its flash memory uses it to reconfigure its own Rack PDU settings and then deletes the file m al YN U V U Q C im gt ua 153 m m C x V c o Q c gt e Contents of the ini file The config ini file that you retrieve from a Switched Rack PDU contains the following e section headings which are category names enclosed in brackets and under each section heading keywords which are labels describing specific Rack PDU settings Only section headings and keywords supported for the specific device associated with the Rack PDU from which you Note retrieve the file are included Each keyword is followed by an equals sign and
67. e the certificate signing request CSR with the information that you want the signed server certificate to contain The Country and Common Name fields are required the other fields are optional For the Common Name field enter the IP Address or DNS name of the Switched Rack PDU By default a server certificate is valid for 10 years from the current date and time but you can edit the Validity Period Note Start and Validity Period End fields On the next screen review the summary of the certificate Scroll downward to view the certificate s unique serial number and fingerprints To make any changes to the information you provided click Back and revise the information Q The certificate s subject information and the certificate s issuer information should be identical Note The last screen verifies that the certificate signing request has been created and displays the location and name of the file which has a csr extension 143 8 Send the certificate signing request to an external Certificate Authority either a commercial Certificate Authority or if applicable a Certificate Authority managed by your own company or agency eS See the instructions provided by the Certificate Authority regarding the signing and issuing of server certificates See also Import the signed certificate When the external Certificate Authority returns the signed certificate perform these steps to import the certificate This proc
68. edure combines the signed certificate and the private key into an SSL server certificate that you then upload to the Switched Rack PDU Click Next to move from screen to screen 1 On the Windows Start menu select Programs then APC Security Wizard to start the Wizard program 2 On the screen labeled Step 1 select Import Signed Certificate 3 Browse to and select the signed server certificate that you received from the external Certificate Authority The file has a cer or crt extension 4 Browse to and select the file you created in step 4 of the task Create the Certificate Signing Request CSR This file has a p15 extension contains the Switched Rack PDU s private key and by default is located in the installation folder C Program Files American Power Conversion APC Security Wizard 5 Specify a name for the output file that will be the signed server certificate that you upload to the Rack PDU The file must have a p15 extension 6 Click Next to generate the server certificate The certificate s Issuer Information on the summary screen confirms that the external Certificate Authority signed the certificate m m am YN U V U Q C UJ gt WY 144 7 The last screen verifies that the certificate has been created and instructs you on the next task to load the server certificate to the Switched Rack PDU It displays the location and name of the server certificate which has a p15 file exten
69. enu of the Web interface of the Switched Rack PDU select the Web SSL option 2 In the SSL TLS Server Certificate section of the page browse to the server certificate the p15 file you created in the procedure Create a Root Certificate amp Server Certificates The default is C Program Files American Power Conversion APC Security Wizard Alternatively you can use FTP or Secure CoPy SCP to transfer Q the server certificate to the Rack PDU If you use FTP or SCP for the transfer you must specify the correct location sec on the Rack PDU For SCP the command to transfer a certificate named cert p15 to a Rack PDU with an IP address of 156 205 6 185 would be Note scp cert p15 apc 156 205 6 185 sec cert p15 m m ai e v Cz o U lt U s e 141 Create a Server Certificate and Signing Request Summary Use this procedure if your company or agency has its own Certificate Authority or if you plan to use a commercial Certificate Authority to sign your server certificates Create a Certificate Signing Request CSR The CSR contains all the information for a server certificate except the digital signature This process creates two output files The file with the p15 extension contains the Switched Rack PDU s private key The file with the csr extension contains the certificate signing request which you send to an external Certificate Authority When you receive the signed certificate from
70. erify a file transfer see Verifying Upgrades and Updates m m am MN U V U Q C UJ bam gt WY 161 m m C x V c o Q c gt e Upgrading Firmware Methods and Tools Benefits of upgrading firmware Upgrading the firmware on the Switched Rack PDU has the following benefits New firmware has the latest bug fixes and performance improvements New features become available for immediate use Keeping the firmware versions consistent across your network ensures that all Switched Rack PDUs support the same features in the same manner Firmware files Switched Rack PDU A firmware version consists of two modules An APC Operating System AOS module and an application module The APC Operating System AOS and application module files used with the Switched Rack PDU share the same basic format apc hwOx type version bin apc Indicates that this is an APC file e hw0 x Identifies the version of the Switched Rack PDU that will run this binary file e type Identifies whether the file is for the APC Operating System AOS or the application module APP for the Switched Rack PDU version The version number of the application file For example a code of 266 would indicate version 2 6 6 bin Indicates that this is a binary file 162 Obtain the latest firmware version Automated upgrade tool for Microsoft Windows systems An automated self extracting executable tool combin
71. es not receive a response within that time e mail cannot be sent Therefore use DNS servers that are on the same segment as the Rack PDU or on a nearby segment but not across a WAN Once you define the IP addresses of the DNS servers verify that DNS is working correctly Enter the DNS name of a computer on your network to test whether you can look up the IP address for that DNS name SMTP settings The Email option in the Network menu accesses the following settings Setting Description SMTP Server Defines the SMTP server by its DNS name NOTE This definition is required only when the SMTP Server option see Email Recipients is set to Local From Address Defines the contents of the From field in the e mail messages sent by the Rack PDU NOTE The SMTP server s configuration may require that you use a valid user account on the server for this setting See the server s documentation for more information m m C x V c o Q c gt e Email Recipients 65 2 Q ai U V aa U UV te Y gt N In the Web interface use the Recipients option in the Events menu or the Configure the Email recipients link in the Email Configuration page to identify up to four e mail recipients Use the Email Test option to send a test message to a configured recipient In the control console use the Email option in the Network menu to access the e mail recipient settings S
72. es the firmware modules that you need to automate your upgrades on any supported Windows operating system The version of the tool on the APC Rack PDU Utility CD that came with your Rack PDU will upgrade your device to the latest AOS and application modules available when the CD was released e If a later firmware upgrade is available you can obtain an updated version of the tool at no cost from the support section of the APC web site www apc com tools download At this Web page find the latest firmware release for your APC product in this case your Rack PDU and download the automated tool not the individual firmware modules If the AOS firmware module you already have is a 1 x x version the executable tool must perform two consecutive upgrades The first upgrade is from version 1 x x to the latest available 2 0 x version of the AOS firmware module The second upgrade is from the 2 0 x version to the most recently released version of the AOS module The tool therefore contains firmware modules for both upgrades Each upgrade tool is specific to an APC product type Do not use the tool from one product CD to upgrade firmware of a different APC product If you use a version of the tool from the APC Web site make sure that you use the upgrade tool that corresponds with your APC product type m m al v Cz o U te U s e 163 m m C x V c o Q c gt e Manual upgrades primarily f
73. ess for each Rack PDU When a user accesses the Switched Rack PDU it sends an authentication request to the RADIUS server to determine the user s permission level Q RADIUS user names are limited to 32 characters Note For more information on user permission levels see Types of user accounts The RADIUS server and the Rack PDU must be configured before RADIUS authentication and authorization will operate properly RADIUS servers use port 1812 by default to authenticate users To use a different port add a colon followed by the new port number to the end of the RADIUS server name or IP address gt Q ai U V aa U UV te Y gt N 101 m m C x V c o Q c gt e Configuring the Rack PDU RADIUS Setting Definition Access Local Only RADIUS is disabled Local authentication is enabled RADIUS then Local RADIUS is enabled and local authentication is enabled Authentication is requested from the RADIUS server first local authentication is used only if RADIUS authentication fails RADIUS Only RADIUS is enabled Local authentication is disabled NOTE If RADIUS Only is selected the only way to recover if the RADIUS server is unavailable is by using a serial connection to the control console and changing the Access setting to Local Only or RADIUS then Local Primary Server Primary Server Secret The server name or IP address of the main RADIUS
74. et groups synchronize 6 outlets 2 in one group and 4 in the other This local outlet group synchronizes 3 outlets on the same Switched Rack PDU E EHE 88 2 E E E u E E E E m A aa U t v c Y a gt V 40 m m C x V c o Q c gt e Verify your setup and configuration for global outlet groups To ensure that your setup meets all system requirements for outlet group and that you have configured the outlet groups correctly select Outlet Groups from the Outlets menu in the Web interface to view the groups and their connections The Configured Outlet Groups section displays the following All configured outlet groups on the current Switched Rack PDU The outlets in each group by outlet number Any outlet groups on other Switched Rack PDUs with which a global outlet group is synchronized Each Switched Rack PDU is identified by its IP address and each global outlet is displayed in bold text The Global Outlet Overview section displays the following The IP address of the current Switched Rack PDU The IP address of any Switched Rack PDUs that contain global outlets that are available to be synchronized with outlet groups on other Switched Rack PDUs All global outlets configured on the Switched Rack PDUs listed regardless of whether they are synchronized with outlet groups on the current Switched Rack PDU 41 Outlet Set
75. etting Description To Address Defines the user and domain names of the recipient To bypass the DNS lookup of the mail server s IP address use the IP address in brackets instead of the e mail domain name For example use jsmith xxx xxx xxx xxx instead of jsmith company com This is useful when DNS lookups are not working correctly To use e mail for paging use the e mail address for that recipient s pager gateway account for example myacct100 skytel com The pager gateway pages the recipient The recipient s pager must be able to use text based messaging 66 m m ai e V Cz o U lt U s e Setting Description SMTP Selects one of the following methods for routing e mail Server Through the SMTP server provided with the Rack PDU the recommended option Local This option ensures that the e mail is sent before the 20 second time out for the Rack PDU and if necessary is retried several times Also do one of the following Enable forwarding at the SMTP server provided with the Rack PDU so that it can route e mail to external SMTP servers Typically SMTP servers are not configured to forward e mail Always check with the administrator of your SMTP server before changing its configuration to allow forwarding Set up a special e mail account for the Rack PDU to forward e mail to an external mail account Directly to the recipient s SMTP server the Recipient s
76. ettings see the nstallation and Quick Start manual provided as a PDF file on the Utility CD that came See also With your Rack PDU and as a printed manual m m C x V c o Q c gt e Access Procedures Overview The Switched Rack PDU has two internal interfaces control console and Web interface that allow you to manage the Rack PDU For more information about the internal user interfaces see Control Console and Web Interface The SNMP interface also allows you to use an SNMP browser with the PowerNet Management Information Base MIB to manage the Rack PDU To use the PowerNet MIB with an SNMP browser see the eS PowerNet SNMP Management Information Base MIB Reference Guide doc en mibguide pdf which is provided on the See also Utility CD that came with your Switched Rack PDU Access priority for logging on Only one user at a time can log on to the Rack PDU to use its internal user interface features The priority for access is as follows Local access to the control console from a computer with a direct serial connection to the Rack PDU always has the highest priority Telnet or Secure SHell SSH access to the control console from a remote computer has priority over Web access Web access either directly or through the InfraStruXure Manager has the lowest priority m m am MN U V U Q C UJ Lo gt WY Types of user accounts The Rack PDU has four
77. failed to connect to the network N Another device is using the IP address of the Rack PDU A The application is functioning properly A The application has a bad checksum A The application is initializing A The application is not compatible with the AOS Note If the AOS status is not P contact APC Worldwide Customer Support even if you can still access the Rack PDU A Rack PDU model and name field reports the status of the Rack PDU For example Switched Rack PDU Communication Established 20 Control Console Menus Menu structure The menus in the control console list options by number and name To use an option type the corresponding number and press ENTER then follow any on screen instructions For menus that allow you to change a setting you must use the Accept Changes option to save the changes you made While in a menu you can also do the following Type and press ENTER to access brief menu option descriptions if the menu has help available Press ENTER to refresh the menu Press ESC to go back to the menu from which you accessed the current menu Press CTRL C to return to the main control console menu Press CTRL L to access the event log Administrator and Device Manager only For information about the event log see Event Related Menus m m am MN U V Ee U Q C UJ gt V 21 E m A aa U t v c Y ad gt V
78. ficate in advance reduces the time required to enable HTTPS SSL TLS If no server certificate is loaded when you enable HTTPS SSL TLS the Rack PDU creates one when it reboots The Rack PDU can take up to 5 minutes to create this certificate and the SSL TLS server is not available during that time Note Display the configured parameters of a digital server certificate if one is installed 89 m A aa U t v c Y a gt V Option Description Web SSL Network Configuration Access Enables or disables the access method selected in Protocol Mode Protocol Mode Choose one of the following HTTP User names passwords and data are transmitted without encryption HTTPS SSL TLS User names passwords and data are transmitted in encrypted form and digital certificates are used for authentication NOTE To enable HTTPS SSL TLS change the setting and then click Next gt gt in the Web interface or choose Accept Changes in the control console You must then agree to the license agreement that is displayed To activate the changes you must log off and log back on to the interface When SSL is activated your browser displays a lock icon usually at the bottom of the screen 90 m m C x V c o Q c gt e Option Description HTTP HTTPS Port Configuration HTTP Port Identifies the TCP IP port used for communications by
79. for authentication from being used by anyone intercepting network traffic To authenticate the SSH server the Switched Rack PDU to the SSH client SSH uses a host key that is unique to the SSH server and that provides an identification that cannot be falsified Therefore an invalid server on the network cannot obtain a user name and password from a user by presenting itself as a valid server eS To create a host key see Create an SSH Host Key See also The Switched Rack PDU supports versions 1 and 2 of SSH The encryption mechanisms of the versions differ and each version has advantages Version 1 provides faster login to the Rack PDU and version 2 provides improved protection from attempts to intercept forge or change data that are transmitted e When you enable SSH Telnet is automatically disabled The interface user accounts and user access rights are the same whether you access the control console through SSH or Telnet For information on supported SSH client applications see Telnet SSH 122 m m D c U v c Y ad gt WY Secure CoPy SCP is a secure file transfer application that you can use instead of FTP SCP uses the SSH protocol as the underlying transport protocol for encryption of user names passwords and files When you enable and configure SSH you automatically enable and configure SCP No further configuration of SCP is needed You must explicitly disable FTP
80. git year for log entries You may need to select a four digit date format in your spreadsheet Note application to display all four digits of the year m m C x c o Q c gt e 57 m m C x V c o Q c gt e Secure CoPy SCP To use SCP to retrieve the event txt file use the following command scp usernameQ hosthame or ip address event txt event txt To use SCP to retrieve the data txt file use the following command scp usernameQhosthame or ip address data txt data txt See Data Menu Web Interface Only for information about the data log File Transfer Protocol FTP To use FTP to retrieve the event txt or data txt file 1 At a command prompt type ftp and the IP address of the Switched Rack PDU and press ENTER If the Port setting for FTP Server in the Network menu has been changed from its default value 21 you must use the non default value in the FTP command For some FTP clients you must use a colon to add the port number to the end of the IP address For Windows FTP clients use the following command including spaces ftp gt open ip address port number To use non default port values to enhance security see Port assignments 2 Use the case sensitive User Name and Password values for either an Administrator or a Device Manager User to log on For Administrator apc is the default for User Name and Password For Device Manager device is
81. gout lt ESC gt Main Menu ENTER Refresh CTRL L Event Log 18 Information and status fields Main screen information fields Two fields identify the APC operating system AOS and application APP firmware versions The application firmware uses a name that identifies the type of device that connects to the network In the Example main screen the application firmware for the Rack PDU is displayed Network Management Card AOS v2 6 4 Rack PDU APP v2 6 6 Three fields identify the system Name Contact and Location values Name MS3 Test Unit Contact Bill Cooper Location Testing Lab To set the Name Contact and Location values see System Menu An Up Time field reports how long the Rack PDU has been running since it was last reset or since power was applied Up Time 0 Days 0 Hours 43 Minutes Two fields identify when you logged on by Date and Time Date 6 25 2004 Time 10 16 58 A User field identifies whether you logged on as Administrator Device Manager or Outlet User User Administrator m A aa U t v c Y a gt V m A aa U t v c Y a gt V Main screen status fields A Stat field reports the Rack PDU status Stat P N A P The APC operating system AOS is functioning properly N The network is functioning properly N A BOOTP request cycle is in progress N The Rack PDU
82. he Web interface of the Switched Rack PDU select the Telnet SSH option 2 In the SSH User Host Key File section of the page browse to the host key the p15 file you created in the procedure Create the host key The default location is C Program Files American Power Conversion APC Security Wizard 3 On the SSH Host Key Fingerprint section of the page note the fingerprint for the version or versions of SSH you are using Then log on to the Rack PDU through your SSH client program and verify that the correct host key was uploaded by verifying that these fingerprints match the fingerprints that the client program displays Alternatively you can use FTP or Secure CoPy SCP to transfer the host key file to the Rack PDU If you use FTP or SCP for the transfer you must specify the correct location sec on the Rack PDU For SCP the command to transfer a host key named hostkey p15 to a Rack PDU with an IP address of 156 205 6 185 would be Note scp cert p15 apc 156 205 6 185 sec hostkey pl5 m m ai e Y Cz o U lt U s e 147 APC Device IP Configuration Wizard Purpose and Requirements Purpose configure basic TCP IP settings You can use the APC Device IP Configuration Wizard to configure the basic TCP IP settings IP address subnet mask and default gateway of the following Network Management Cards Devices that contain embedded Network Management Cards Using the Wizard you can config
83. he certificate cache of the browser The CA certificates of commercial Certificate Authorities are distributed as part of the browser software and a Certificate Authority of your own company or agency has probably already loaded its CA certificate to the browser store of each user s browser Therefore you do not have to upload a root certificate to the browser of each user who needs access to the Rack PDU The length of the public key RSA key that is used for setting up an SSL session is 1024 bits providing more complex encryption and consequently a higher level of security than the public key used in Method 1 This longer encryption key is also used in Method 2 m al YN U V U Q C im gt ua 131 The server certificate that you upload to the Rack PDU enables SSL to authenticate that data are being received from and sent to the correct Rack PDU This provides an extra level of security beyond the encryption of the user name password and transmitted data The browser matches the digital signature on the server certificate that you uploaded to the Rack PDU with the signature on the CA root certificate that is already in the browser s certificate cache to provide additional protection from unauthorized access Disadvantages Setup requires the extra step of requesting a signed root certificate from a Certificate Authority An external Certificate Authority may charge a fee for providing
84. he network The IP address of the Rack PDU The subnet mask value The IP address of the default gateway For information about the watchdog role of the default gt gateway see Resetting the network timer For information about how to configure the initial TCP IP settings when you install the Rack PDU see the nstallation and Quick Start manual doc en insguide pdf provided on See also the APC Rack PDU Utility CD that came with your Rack PDU and as a printed manual Advanced settings define the Rack PDU s host and domain names as well as TCP IP port BOOTP and DHCP settings used by the Rack PDU Current TCP IP settings fields The current values for System IP Subnet Mask and Default Gateway and the Rack PDU s MAC Address Host Name Domain Name and Ethernet Port Speed values are displayed above the TCP IP settings in the control console and the Web interface m m C x c o Q c gt e 73 m m al YN U V U Q C im gt WY Boot mode setting This setting selects which method will be used to define the Rack PDU s TCP IP settings whenever the Rack PDU turns on resets or restarts Manual Three settings System IP Subnet Mask and Default Gateway which are available only when Manual is used to define the needed TCP IP settings BOOTP only A BOOTP server provides the TCP IP settings DHCP only A DHCP server provides the TCP IP setting
85. he same version number which must be 2 6 1 or higher for both the APC Operating System AOS module and the Application module As later firmware revisions become available be sure to upgrade each Switched Rack PDU You need a computer that can initiate synchronized control operations through the Web interface or control console of the Switched Rack PDUs or through SNMP You must ensure that Multicast network traffic is allowed for the selected Multicast IP address by each switch that connects the Switched Rack PDUs 35 Rules for configuring outlet groups For a system that uses outlet groups the following rules apply A Switched Rack PDU can have more than one outlet group but an outlet can belong to only one outlet group A local outlet group which has no global outlet must consist of two or more outlets You can synchronize a global outlet group on one Switched Rack PDU with a global outlet group on each of three other Switched Rack PDUs n a global outlet group you can designate only one outlet to be a global outlet linking to outlet groups on other Switched Rack PDUs for the purpose of synchronization That global outlet can be the only outlet in its group or the group can consist of multiple outlets For outlet groups on Switched Rack PDUs to be linked for synchronization those Switched Rack PDUs must have the same Device Multicast Name and Device Multicast Address and be running the same version of
86. hed Rack PDU Low load threshold exceeded Warning For information about severity levels and how they define the actions associated with events see Event Actions Web Interface Only Detailed Event Action Configuration page The event codes provide a link to a page that allows you to do the following e Change the selected events severity level Enable or disable whether the event uses the event log Syslog messages SNMP traps or e mail notifications m m C x V c o Q c gt e 68 Data Menu Web Interface Only Log Option Use this option to access a log that stores information about the Switched Rack PDU lout The power being output by the Rack PDU loutmax The maximum power output by the Rack PDU since its output power was last recorded loutmin The minimum power output by the Rack PDU since its output power was last recorded Use the Data menu s Configuration option to define how frequently data is sampled and stored in the data log Each entry is listed by the date and time the data was recorded and provides the data in a column format See Configuration Option To retrieve the data log as a text file see How to use FTP or SCP to retrieve a log file m m am MN U V U Q C UJ bam gt WY 69 Configuration Option Use this option to access the Data Log Configuration page which reports how much data can be stored in the data l
87. her the Web or control console interfaces outlet groups enabled at the beginning of the scheduled action Q For an action to be applied to an outlet group you must have For example if Off Delayed is scheduled for 4 00 p m the Power Note Off Delay begins at 4 00 p m Even if you then enable outlet groups during that Power Off Delay before any of the outlets are scheduled to turn off the action will be applied only to the individual outlet and not the outlet group Option Description No Action Do nothing On Immediate Apply power to the selected outlets On Delayed Apply power to each selected outlet according to its value for Power On Delay t Off Immediate Remove power from the selected outlets T If an outlet group is selected the configured delays and reboot duration of the lowest numbered outlet for a local outlet group or of the global outlet for a global outlet group that is initiating the action 49 E m A aa U t v c Y a gt V Option Description Off Delayed Remove power from each selected outlet according to its value for Power Off Delay Reboot PDU Remove power from each selected outlet Then apply power to Immediate each of these outlets according to its value for Reboot Duration Reboot PDU Remove power from each selected outlet according to its value for Delayed Power Off Delay Wait until all outlets are off the highest
88. hows the number phase or bank for 3 phase models state on off and name of the outlet The Switched Rack PDU Parameters section shows the following The Name Contact and Location information for the Rack PDU The date and time you logged on The Type of User Administrator Device Manager Read Only User or Outlet User The time Up Time the Rack PDU has been running continuously since it was last reset or power was applied The rating of the Rack PDU 1 or 3 phase and the maximum number of amps per phase or bank 27 Quick status tab The quick status tab is displayed at the upper right on every page in the Web interface The tab shows active alarms and warnings and a link to the online help Click the help icon to access the online help for the displayed page Click the green device operating normally icon to return to the status screen where the current for each phase or bank is displayed Click the warning icon to return to the status screen where active warnings are displayed Put the mouse cursor on the icon to view details of the warning Click the alarm icon to return to the status screen where active alarms are displayed Put the mouse cursor on the icon to display details of the alarm v AN e m A aa U t v c Y a gt V 28 m A aa U t v c Y a gt V Navigation Menu Overview On the Web inte
89. http or https as part of the address when any port other than 80 is used If the error You are not authorized to view this page occurs Note For more information see Port assignments For a DNS name of Web1 the entry would be one of the following http Web1 if HTTP is your access mode https Web1 if HTTPS SSL TLS is your access mode For a System IP address of 139 225 6 133 when the Rack PDU uses the default port 80 at the Web server the entry would be one of the following http 139 225 6 133 if HTTP is your access mode https 139 225 6 133 if HTTPS SSL TLS is your access mode For a System IP address of 139 225 6 133 when the Rack PDU uses a non default port 5000 in this example at the Web server the entry would be one of the following http 139 225 6 133 5000 if HTTP is your access mode https 139 225 6 133 5000 if HTTPS SSL TLS is your access mode 26 m m C x V c o Q c gt e Summary Page When you log on to the Web interface at the Switched Rack PDU the status view is at the right side of the screen the quick status tab is at the upper right and the navigation menu is at the left Status The Status view has three sections The Device Status section reports any active alarm or warning conditions and displays the load for each phase or bank including a graphic representation of the load thresholds The Outlet Status section s
90. ia XMODEM CRC After the XMODEM transfer is complete set the baud rate to 9600 The Rack PDU will automatically restart Repeat step 3 through step 8 to install the application module In step 8 substitute the application module file name for the AOS module file name For information about the format used for application modules see Firmware files Switched Rack PDU 169 m m ai e V Cz o U lt U s Verifying Upgrades and Updates Overview To verify that the firmware upgrade was successful see the Last Transfer Result message available through the FTP Server option of the Network menu in the control console only or use an SNMP GET to the mfiletransferStatusLastTransferResult OID Last Transfer Result codes Code Description Successful The file transfer was successful Result not available There are no recorded file transfers Failure unknown The last file transfer failed for an unknown reason Server inaccessible The TFTP or FTP server could not be found on the network Server access denied The TFTP or FTP server denied access File not found The TFTP or FTP server could not locate the requested file File type unknown The file was downloaded but the contents were not recognized File corrupt The file was downloaded but at least one CRC was bad You can also verify the versions of the upgraded APC Operating System AOS
91. ical conditions Error Error conditions Warning Warning conditions Notice Normal but significant conditions Informational Informational messages Debug Debug level messages Following are the default settings for the four Local Priority settings Severe is mapped to Critical Warning is mapped to Warning Informational is mapped to Info None for events that have no severity level assigned is mapped to Info NOTE To disable sending Syslog messages for Severe Warning or Informational events see Event Actions Web Interface Only Syslog test Web interface This option allows you to send a test message to the Syslog servers configured in the Syslog Server section 87 m m ai e V Cz o U lt U s e 1 For Priority select the priority to assign to the test message 2 For Test Message use any text that meets the format described in Syslog message format for example APC Test message 3 Click Apply to have the Rack PDU send a Syslog message that uses the defined Priority and Test Message settings Syslog message format A Syslog message has three parts The priority PRI part identifies the Syslog priority assigned to the message s event and the facility code assigned to messages sent by the Rack PDU The header includes a time stamp and the IP address of the Rack PDU The message MSG part has two fields A TAG field which is followed by a colon a
92. ificate that the Rack PDU generates has some limitations See Method 1 Use the auto generated default certificate You can create a server certificate with the APC Security Wizard and then upload it to the Rack PDU by using the Web interface Use the Browse button for the Filename field to locate the file then click Apply By default the certificate is installed to the correct location Alternatively you can use FTP or Secure CoPy SCP to transfer the server certificate to the Rack PDU However you must specify the correct location sec on the Rack PDU NOTE Creating and uploading a server certificate in advance reduces the time required to enable HTTPS SSL TLS If no server certificate is loaded when you enable HTTPS SSL TLS the Rack PDU creates one when it reboots The Rack PDU can take up to 5 minutes to create this certificate and the SSL TLS server is not available during that time 93 m m al V Cz o U te U s e Parameter Description Current Certificate Details Issued to Common Name CN The IP Address or DNS name of the Rack PDU except if the server certificate was generated by default by the Rack PDU For a default server certificate the Common Name CN field displays the Rack PDU s serial number NOTE If an IP address was specified as the Common Name when the certificate was created use an IP address to log on to the Web interface of the Rack PDU if the DNS name w
93. ing defines the password maximum of 15 characters used when traps are sent to the NMS identified by the Receiver NMS IP Domain Name setting Receiver NMS IP Domain Name Identifies by IP address or domain name the NMS that will receive traps If this setting is 0 0 0 0 the default value traps will not be sent to any NMS Generation Web interface Trap Generation control console Enables by default or disables the sending of any traps to the NMS identified by the Receiver NMS IP Domain Name setting Authentication Traps Enables or disables the sending of authentication traps to the NMS identified by the Receiver NMS IP Domain Name setting 63 E mail Feature Overview You can use the Simple Mail Transfer Protocol SMTP to send e mail to up to four recipients when an event occurs To use the e mail feature you must define the following settings The IP addresses of the primary and secondary Domain Name System DNS servers SMTP Q You can use the To Address setting of the Email Recipients option to send e mail to a text based pager Note E m A aa U t v c Y ad gt V 64 DNS servers The Rack PDU cannot send any e mail messages unless the IP address of the primary DNS server is defined See DNS The Rack PDU will wait a maximum of 15 seconds for a response from the primary or if specified the secondary DNS server If the Rack PDU do
94. ion Setting Description Overload Alarm Threshold Set the number of amps that will cause an overload of this phase or bank Near Overload Warning Threshold Set the number of amps at which to generate a warning that the Rack PDU is nearing overload of a phase or bank 46 m m C x c o Q c gt e Setting Description Low Load Warning Set the low threshold in amps for the current drawn from this Threshold phase or bank during normal operation A load at or below this level generates a warning Overload Outlet Prevent users from applying power to outlets during an overload Restriction condition You can set the following restrictions for each outlet None You can apply power to outlets regardless of an Overload Alarm or Near Overload Warning On Warning You cannot apply power to an outlet on the selected phase or bank if the current for that phase or bank has exceeded the Near Overload Warning threshold On Overload You cannot apply power to an outlet on the selected phase or bank if the current for that phase or bank has exceeded the Overload Alarm threshold How to configure Device Settings Web interface Select Configuration on the Switched Rack PDU menu Then under Device Settings click the Configure button and configure the Name and Location fields for the Rack PDU and set the Coldstart Delay Control console 1 Select Outlet Co
95. ion 43 notifies the Rack PDU that a DHCP server has been configured to service APC devices By default the APC Cookie must be present in this DHCP response option before the Rack PDU can accept the lease Q Use the DHCP Cookie Is setting described in Switched Rack PDU settings to disable the APC cookie requirement Note Following in hexadecimal format is an example of a Vendor Specific Information option that contains the APC cookie Option 43 0x01 0x04 0x31 0x41 0x50 0x43 a C x V c o Q c gt e 114 m m C x c o Q c gt e Boot Mode Transition Tag 2 Len 1 Data 1 2 This option 43 setting enables or disables the After IP Assignment option which by default causes the Boot mode option to use the setting that reflects the server that provided the TCP IP settings DHCP Only or BOOTP Only For a data value of 1 the After IP Assignment option is disabled and the Boot mode option remains in its DHCP amp BOOTP setting after successful network assignment Whenever the Switched Rack PDU restarts it will request its network assignment first from a BOOTP server and then if necessary from a DHCP server See DHCP amp BOOTP boot process For a data value of 2 the After IP Assignment option is enabled and the Boot mode option switches to DHCP Only when the embedded management card accepts the DHCP response Whenever the Rack PDU restarts it will request it
96. it can never use SETs Write The NMS can use GETs at any time and can use SETs when no one is logged on to either the control console or Web interface Disabled The NMS cannot use GETs or SETs Write The NMS can use GETs and SETS at any time even when someone is logged on to the control console or Web interface Email Use this option to define two SMTP settings SMTP Server and From Address used by the e mail feature of the Switched Rack PDU See SMTP settings and E mail Feature m m C x V c o Q c gt e 85 An Access option the Settings option in the control console enables by default or disables SNMP When SNMP is enabled the Access Control settings allow you to control how each of the four available SNMP channels is used Syslog By default the Rack PDU can send messages to up to four Syslog servers whenever System embedded management card and Switched Rack PDU Device events occur The Syslog servers which must be specifically identified by their IP addresses or domain names record the events in a log that provides a centralized record of events that occur at network devices This user s guide does not describe Syslog or its configuration values in detail For more information about Syslog see User by default NOTE Although several daemon specific and process specific selections are available along with eight generic selections Use
97. l instances set the domain name field in Configure General Settings to its default somedomain comorto 0 0 0 0 To override the behavior for a particular host name entry for example when defining a trap receiver include a trailing period The Switched Rack PDU recognizes a host name with a trailing period such as mySnmpServer asifit were a fully qualified domain name and therefore does not append the domain name A Port Speed setting is available for all Boot mode selections to define the TCP IP port s communication speed Auto negotiate by default Three settings are available for all Boot mode selections except Manual to identify the Rack PDU in BOOTP or DHCP communication Vendor Class Uses APC by default Client ID Uses the Rack PDU s MAC address by default If the Client ID is changed from the Rack PDU s MAC address the new value must be unique on the LAN Caution Otherwise the DHCP or BOOTP server may act incorrectly User Class Uses the Rack PDU s application module type by default Two settings are available if BOOTP only is the Boot mode selection Retry Then Fail Defines how many times the Rack PDU will attempt to discover a BOOTP server before it stops 4 by default 75 On Retry Failure Defines what TCP IP settings will be used by the Rack PDU when it fails to discover a BOOTP server Use Prior Settings by default For information about the Advanced settings DHCP
98. led by default Setting Definition Primary NTP Server Identifies the IP address or domain name of the primary NTP server Secondary NTP Server Identifies the IP address or domain name of the secondary NTP server when a secondary server is available Time Zone Defines the offset to be used from Greenwich Mean Time GMT based on the time zone in which the Rack PDU is located Update Interval Defines how often in hours the Rack PDU will access the NTP Server for an update The minimum interval is 1 hour and the maximum is 8760 hours one year Use Update Using NTP Now to initiate an immediate update as well 106 m m ai e V Cz o U lt U s Tools Use this option to perform the following actions Action Definition No Action Web Interface only No change to the Rack PDU Reboot Management Interface Restarts the user interface of the Rack PDU Reset to Defaults Reset to Defaults Resets all configuration settings This option will reset the TCP IP settings and enable DHCP and BOOTP Resets all configuration settings except the TCP IP settings Except TCP IP Reset Only TCP IP Resets the TCP IP settings only This option will not enable to Defaults DHCP and BOOTP Delete SSH Host Keys and SSL Certificates Removes all host keys you configured for Secure SHell for encryption based security at the control console and all
99. levels of access Administrator Device Manager Read Only User and Outlet User all of which are protected by password and user name requirements An Administrator can use all of the management menus available in the control console and the Web interface The Administrator s default user name and password are both apc A Device Manager can use only the following menus The Device Manager menu and its sub menus in the control console and all menus in the top section of the navigation panel of the Web Interface Switched Rack PDU and Outlets The Log option in the Events menu in the Web interface A Device Manager can also access the event log in the control console by pressing CTRL L The Device Manager s default user name is device the password is apc An Outlet User can access only the following menus the Control option of the Outlets menu of the Web interface the Device Manager menu and the Phase Bank Monitor Outlet Control and Power Supply Status sub menus in the control console A Read Only User has the following restricted access Access through the Web interface only Access to the same menus as a Device Manager but without the capability to change configurations control devices or delete data Links to configuration options are visible but are disabled and the event and data logs display no Delete button The Read Only User s default user name is readonly and the default password is a
100. ll of the online help is displayed However from any Web interface pages you can use the question mark in the quick status bar to link to the section of the online help for that page The About System option of the Help menu displays information in the following fields Model Number Serial Number Hardware Revision Manufacture Date MAC Address Application Module APC OS AOS Module the APC Operating System Module of the Switched Rack PDU and the date and time that each of the two modules were created m m ai e V Cz o U lt U s 31 2 Q ai U V aa U UV te Y gt N Q In the control console the About System option which is a System menu option has the Flash Type value Note Links menu Provides three user definable URL link options By default these links access the following APC Web pages APC s Web Site accesses the APC home page e Testdrive Demo accesses a demonstration page where you can use samples of APC Web enabled products e APC Monitoring accesses the APC Remote Monitoring Service page about pay for monitoring services available from APC To redefine these links so that they point to other URLs 1 Click on Links in the System menu 2 Define any new names for User Links 3 Define any new URL addresses that you want User Links to access Only HTTP links may be defined 4 Click Apply Q The link associated with the APC logo is also definable
101. log action By default the Syslog action is enabled for all events that have a severity level However before you can use this feature to send Syslog messages when events occur you must configure it See Syslog SNMP traps action By default the SNMP Traps action is enabled for all events that have a severity level assigned However before you can use SNMP traps for event notifications you must identify the NMSs by their IP addresses or domain names that will receive the traps To define up to four NMSs as trap receivers see Event Recipients Email action By default the Email action is enabled for all events that have a severity level assigned However before you can use e mail for event notifications you must define the e mail recipients See E mail Feature 62 m m C x V c o Q c gt e Event Recipients Overview The Web interface and control console both have options that allow you to define up to four trap receivers and up to four e mail addresses to be used when an event occurs that has SNMP traps or e mail enabled Trap Receiver settings See Event Actions Web Interface Only To access the Trap Receiver settings that allow you to define which NMSs will receive traps In the Web interface use the Recipients option in the Events menu n the control console use the SNMP option in the Network menu Item Definition Community Name This sett
102. mat 67 Enabling e mail forwarding to external SMTP servers 67 e mail to a recipient 67 Reverse DNS Lookup 77 sending any traps to an NMS 63 sending authentication traps to an NMS 63 SSH 80 Syslog 86 Telnet 80 Encryption with SSH and SCP 122 m m C x V c o Q c gt e with SSL 88 Error messages for firmware file transfer 170 from overridden values during ini file transfer 159 Ethernet Port Speed setting 112 Event Log accessing 21 disabling 61 errors from overridden values during ini file transfer 159 using FTP del command 59 using FTP to retrieve 57 event txt file contents 57 importing into spreadsheet 57 Events menu Actions 60 E mail Web interface 62 EventLog 61 SNMP traps 62 F Facility setting 86 File Transfer 107 Fingerprints displaying and comparing 79 Firewall as essential to security 133 Firmware benefits of upgrading 162 file transfer methods 165 FTPorSCP 166 XMODEM 168 files for Network Management Card 162 obtaining the latest version 163 upgrading 162 verifying upgrades and updates 170 Firmware versions displayed on main screen 19 176 Follower outlet groups 33 From Address 65 FTP 77 disabling when SCP is used 78 to retrieve text version of Event or Data log 57 G Generation e mail recipients 67 Global outlet groups 33 creating 38 verifying setup and configuration 41 Global outlets 33 H Help About System option Web interface 31 on con
103. mation about these pages see Links menu Access Links APC Home Page Defines the URL address used by the APC logo at the top of all Web interface pages by default http www apc com Modem not supported This option shown only in the control console is not supported for Rack PDUs About System This option identifies the following hardware information for the Rack PDU Model Number Serial Number Hardware Revision Manufacture Date and MAC Address 108 This screen also displays the Name Version Date and Time for the Application Module and AOS This information is set at the factory and cannot be changed The control console also includes fields for system Flash Type and Type Sector and CRC16 for each module In the Web interface except for Flash Type this hardware information is reported by the About System option in the Note Help menu m m D I U v c Y ad gt V 109 Introduction Overview In addition to using a BOOTP server or manual settings the Switched Rack PDU can use a dynamic host configuration protocol DHCP server to provide the settings that it needs to operate on a TCP IP network The method used to provide the network settings for the Rack PDU depends on Boot mode a TCP IP option in the Network menu To use a DHCP server to provide the network assignment for the Rack PDU Boot mode must be set either to DHCP amp BOOTP its default
104. n Retry Failure setting 76 OS APC 31 Outlet events described 43 Outlet groups creating local groups 37 deleting 38 editing 38 m m ai e V Cz o U lt U gt enabling 37 follower 33 global 33 initiator 33 local 33 purpose and benefits 34 rules for configuring 36 system requirements 35 typical configurations 39 Outlet Name 44 Outlet settings configuring 44 controlling outlets 42 Outlets global 33 Override keyword in user configuration file 154 P Paging by using e mail 66 Password change for security 119 Passwords default for each type of account 24 for NMS that is a trap receiver 63 User Manager access 98 using non standards ports as extra pass words 120 PDU port assignment 120 Port Speed setting 75 Ports assigning 120 default for FTP Server 78 for HTTP 91 for HTTPS 91 for SSH 81 for Telnet 81 using a non default port forFTP 78 for HTTP 91 178 for HTTPS 91 forSSH 81 for Telnet 81 Power Off Delay 44 Power On Delay 44 Primary NTP Server 106 Primary Server Secret setting for RADIUS 102 Primary Server setting for RADIUS 102 Protocol Mode selecting for control console access 80 selecting for Web access 90 R RADIUS settings 101 Configuring the Rack PDU 102 Configuring the RADIUS server 103 Read access by an NMS 85 Reboot 107 outlets 43 preventing automated reboot for inactivi ty 14 Reboot Duration 44 Receiver NMS IP Domain Name 63 Recipient s SMTP server 67 Reset Onl
105. nd a space identifies the event type System or Device for example A CONTENT field provides the event text followed by a space and the event code W eb SSL Web SSL TLS in the control console Use the Web SSL menu to perform the following tasks Enable or disable the two protocols that provide access to the Web interface of the Switched Rack PDU Hypertext Transfer Protocol HTTP provides access by user name and password but does not encrypt user names passwords and data during transmission Hypertext Transfer Protocol over Secure Sockets Layer HTTPS Secure Sockets Layer SSL encrypts user names passwords and data during transmission and provides authentication of the Switched Rack PDU by means of digital certificates 88 2 Q ai U V aa U UV te Y gt N See Creating and Installing Digital Certificates to choose among the several methods for using digital certificates e Configure the ports that each of the two protocols will use e Select the encryption ciphers that SSL will use e Identify whether a server certificate is installed on the Rack PDU If a certificate has been created with the APC Security Wizard but is not installed n the Web interface browse to the certificate file and upload it to the Rack PDU Alternatively use the Secure CoPy SCP protocol or FTP to upload it to the location sec on the Rack PDU Creating and uploading a server certi
106. ng and Installing Digital Certificates Purpose For network communication that requires a higher level of security than password encryption the Web interface of the Switched Rack PDU supports the use of digital certificates with the Secure Sockets Layer SSL protocol Digital certificates can authenticate the Switched Rack PDU the server to the Web browser the SSL client The sections that follow summarize the three methods of creating implementing and using digital certificates Read these sections to determine the most appropriate method for your system Method 1 Use the auto generated default certificate Method 2 Use the APC Security Wizard to create a CA certificate and a server certificate Method 3 Use the APC Security Wizard to create a certificate signing request to be signed by the root certificate of an external Certificate Authority and to create a server certificate You can also use Method 3 if your company or agency operates its own Certificate Authority Use the APC Security Wizard in the same way but use your own Certificate Note Authority in place of a commercial Certificate Authority 2 Q ai U V aa U UV te Y gt N 126 Choosing a method for your system Using the Secure Sockets Layer SSL protocol you can choose any of the following methods for using digital certificates Method 1 Use the auto generated default certificate When you enable SSL you must reboot the Ra
107. nse to define NTP DNS hostname and domain name settings NTP Server Primary and Secondary option 42 Identifies up to two NTP servers that can be used by the Rack PDU NTP Time Offset option 2 Specifies the offset in seconds of the subnet for the Rack PDU from Coordinated Universal Time UTC DNS Server Primary and Secondary option 6 Identifies one or two DNS servers that can be used by the Rack PDU Host Name option 12 Identifies the hostname maximum length of 32 characters to be used by the Rack PDU Domain Name option 15 Identifies the domain name maximum length of 64 characters to be used by the Rack PDU 116 m am X U V U U C im gt ua Security Security Features Planning and implementing security features As a network device that passes information across the network the Switched Rack PDU is subject to the same exposure as other devices on the network Use the information in this section to plan and implement the security features appropriate for your environment Summary of access methods Serial control console Security Access Access is by user name and password Description Always enabled Remote control console Security Access Description Available methods User name and password Selectable server port Server Enable Disable Secure SHell SSH For high security use SSH With Telne
108. nt for most environments in which sensitive data are not being transferred m m al v Cz o U te U s e 120 E m A aa U t v c Y a gt V To ensure that data and communication between the Switched Rack PDU and the client interfaces such as the control console and the Web interface cannot be intercepted you can provide a greater level of security by using one or more of the following encryption based methods For the Web interface use the Secure Sockets Layer SSL and Transport Layer Security TLS protocols To encrypt user names and passwords for control console access use the Secure SHell SSH protocol To encrypt user names passwords and data for the secure transfer of files use the Secure CoPy SCP protocol For more information on these protocols for encryption based security see Secure SHell SSH and Secure CoPy SCP and Secure Sockets Layer SSL Transport Layer Security TLS 121 m m al V Cz o U te U s e Encryption Secure SHell SSH and Secure CoPy SCP The Secure SHell SSH protocol provides a secure mechanism to access computer consoles or shells remotely The protocol authenticates the server in this case the Switched Rack PDU and encrypts all transmissions between the SSH client and the server SSH is an alternative to Telnet which does not provide encryption SSH protects the username and password the credentials
109. nterface Only Event Recipients E mail Feature How to Configure Individual Events 54 Event Log Overview The Rack PDU supports event logging for all embedded management card application firmware modules To record and display embedded management card and Rack PDU events use any of the following to view the event log Web interface Control console e FTP e SCP m m A x UJ A U U lt Y s WY 55 Logged events By default any event which causes an SNMP trap will be logged except for SNMP authentication failures Additionally the Rack PDU will log its abnormal internal system events However you can use the Actions option in the Web interface s Events menu to disable the logging of events based on their assigned severity level as described in Event Actions Web Interface Only Some System embedded management card events do not have a severity level Even if you disable the event log for all severity Note levels events with no severity level will still be logged To access a list of the System embedded management card and Switched Rack PDU Device events see Event List page W eb interface The Log option in the Events menu accesses the event log This log displays all of the events that have been recorded since the log was last deleted in reverse chronological order The Delete Log button clears all events from the log Control console Press CTRL L to display all the event
110. ntrol Configuration from the Device Manager menu 2 Select Master Control Configuration from the displayed list 3 Select Master Outlet Configuration from the next menu displayed 4 Change the Name Location or Coldstart Delay from this menu 47 Setting Description Name Set the name of the Rack PDU Location Set the location of the Rack PDU Coldstart Delay The time that the Switched Rack PDU delays applying power to the outlets after AC power has been applied to the Rack PDU To change the Contact field the name of the person to contact about the Rack PDU in addition to the Name and Location fields in the control console see Identification Power Supply Status control console only Select Power Supply Status from the Device Manager menu to display the status of the power supplies of the Switched Rack PDU E m A aa U t v c Y ad gt V 48 m m ai e V Cz o U lt U s e Scheduling Outlet Actions Web Interface Only Actions you can schedule For any outlets you select you can schedule any of the following actions to occur daily at intervals of one two four or eight weeks or only once To configure values for Power On Delay Power Off Delay and Reboot Duration for each outlet see How to configure outlet settings and outlet name Although you must use the Web interface to schedule outlet actions you can set these values in eit
111. oad O O O Piless and hold to ihvert display E NC cjsduiy Tunt TH Ay ex en www apc com Serial Port following two front www apc com Serial Port m m C x c o Q c gt e O OK Q Warning 6 BI Q Overload 2 si O Amps Q AX Press to A P Link RX Tx 10 100 select bank I Status Arc www apc com Switched Rack PDU Serial Port Item Function Q Load Indicator LED Identifies overload and warning conditions for the displayed phase or bank See Load indicator LED Input Selector On 3 phase models press the input selector to monitor the current of the next phase or bank For either 1 or 3 phase units press and hold the input selector to display the IP address of the Rack PDU or to invert the display At five seconds the IP address is displayed at ten seconds the displayed numbers invert RJ 12 Serial Port Connects the Rack PDU to a terminal emulator program for local access to the control console Use the supplied serial cable 940 0144 10 100 Base T Connector Connects the Rack PDU to the network Q Status LED See Status LED Link RX TX LED See Link RX TX 10 100 LED Item Function Q Digital Display Displays the curren
112. og If you change the Log Interval setting which defines how often data will be sampled and recorded in the data log the report updates based on the new setting The minimum interval is 60 seconds the maximum interval is 18 hours 12 minutes 15 seconds m m D c U v c Y ad gt V 70 Network Menu Introduction Overview Use the Network menu to do the following tasks Define TCP IP settings including DHCP or BOOTP server settings when one of those types of servers is used to provide the required TCP IP values Use the Ping utility Define and display settings that affect the Switched Rack PDU s settings for DNS FTP Telnet SSH SNMP E mail Syslog and the Web interface SSL TLS Only an Administrator has access to the Network menu Note m m am MN U V U Q C UJ bam gt WY 71 Menu options Unless noted the following options are available in the control console and Web interface e TCP IP e DNS e Send DNS Query Web interface Ping utility control console only FTP Server Telnet SSH SNMP Email Syslog Web SSL Web SSL TLS in the control console e WAP e ISX Protocol control console only m A x UJ A amp U U lt UJ gt v 72 Option Settings TCP IP This option accesses the following settings A Boot mode setting selects the method used to define the TCP IP values that a Rack PDU needs to operate on t
113. on screen that describes the action to be executed type Yes atthe prompt to perform the action 42 m m al MN U V U Q C im Lo gt WY m m ai e V Cz o U lt U s e Control actions you can select Option Description No Action Web interface only On Immediate Do nothing Apply power to the selected outlets On Delayed Apply power to each selected outlet according to its value for Power On Delay Off Immediate Remove power from the selected outlets Off Delayed Remove power from each selected outlet according to its value for Power Off Delay Reboot Immediate Remove power from each selected outlet Then apply power to each of these outlets according to its value for Reboot Duration t Reboot Delayed Remove power from each selected outlet according to its value for Power Off Delay Wait until all outlets are off the highest value for Reboot Duration and then apply power to each outlet according to its value for Power On Delay t Cancel Pending Commands Web Interface Cancel control console Cancel all commands pending for the selected outlets and keep them in their present state NOTE For global outlet groups you can cancel a command only from the interface of the initiator outlet group The action will cancel the command for the initiator outlet group and all follower outlet groups T If a local outlet group i
114. onfiguration Settings 153 Retrieving and Exporting the ini File 153 The Upload Event and Error Messages leen 158 Using the APC Device IP Configuration Wizard 160 File Transfers 161 Introduction a osos x ee eee Re RAD OR RACK ARCA UR a ee 161 Upgrading Firmware Methods and Tools 162 Verifying Upgrades and Updates 0 002 ee eee eee 170 Product Information 171 Warranty and Service s s saa ssim a REPRE EA eos 171 Life Support Policy i 45s 255g khao OR grauen 173 Index 174 m m A x UJ A U U lt Y s WY m am X U V U U c im gt ua Introduction Product Description Features of the Switched Rack PDU The APC Switched Rack Power Distribution Unit PDU is a stand alone network manageable device that provides current monitoring and allows programmable control of eight sixteen or twenty four power outlets depending on the model You can manage a Switched Rack PDU through its Web interface its control console the InfraStruXure Manager or SNMP e The Web interface supports using HTTPS access with Secure Sockets Layer SSL and using HTTP access e You can access the control console through a serial connection Telnet or Secure SHell SSH e Your Rack PDU is compatible with the APC InfraStruXure system and can be monitored and managed through the InfraStruXure Manager You can use
115. or 9600 bps 8 data bits no parity 1 stop bit and no flow control Save the changes 4 Press ENTER repeatedly if necessary to display the User Name prompt 5 Enter your user name and password both apc by default for administrators only and press the ENTER key 6 From the Control Console menu select in order System Tools File Transfer and XMODEM 7T Atthe prompt Perform transfer with XMODEM CRC type YES and press ENTER 8 The system will then prompt you to choose a transfer rate and to change your terminal settings to match the transfer rate Press ENTER to set the Switched Rack PDU to accept the download m m ai e V Cz o U lt U s e m m D I U v c Y ad gt WY 9 In the terminal program send the file using the XMODEM protocol When the transfer finishes the console will prompt you to restore the baud rate to normal Do not interrupt the download Caution The Rack PDU will restart when the download is complete Q Upgrading the firmware will not interfere with the operation of the outlets Note E m A aa U t v c Y a gt V Front Panel Single phase OK Warning Overload Q and hold Amps J to invert display L Q X Three phase Switched Rack PDUs have one of the panels Tunt TUM scu Three phase OK L2 L3 Warning select line Overl
116. or Linux systems If all computers on your network are running Linux you must upgrade the firmware of your Rack PDUs manually i e by using the separate APC firmware modules AOS module and application module If you have a networked computer running a supported Microsoft Windows operating system on your network you can use the tool described in Automated upgrade tool for Microsoft Windows systems to upgrade the firmware of a Switched Rack PDU automatically over the network This tool automates the entire upgrade process even if your current firmware is a 1 x x version When performing a manual upgrade not using the automated tool you cannot upgrade the AOS firmware module of any APC device directly from firmware version 1 x x to firmware version 2 1 0 or later The upgrade attempt will fail You must first upgrade to the latest available 2 0 x version of the AOS module and then to the later version Note You can obtain the individual firmware modules you need for a manual firmware upgrade from the support section of the APC Web site www apc com tools download 164 m m C x V c o Q c gt e Firmware file transfer methods To upgrade the firmware of a Switched Rack PDU From a networked computer running a Microsoft Windows operating system you can use the automated firmware upgrade tool on your CD or downloaded from the APC Web site From a networked computer on any supported operating s
117. ork Configuration Access Enables or disables the access method selected in Protocol Mode NOTE Enabling SSH automatically disables Telnet To enable SSH change the setting and then click Next gt gt in the Web interface or choose Accept Changes in the control console You must then agree to the license agreement that is displayed Protocol Choose one of the following Mode Telnet User names passwords and data are transmitted without encryption Secure SHell SSH version 1 User names passwords and data are transmitted in encrypted form There is little or no delay when you are logging on Secure SHell SSH version 2 User names passwords and data are transmitted in encrypted form but with somewhat more protection than version 1 from attempts to intercept forge or alter data during data transmission There is a noticeable delay when you are logging on to the Rack PDU Secure SHell SSH versions 1 and 2 Do not enable both versions of SSH unless you require that both be activated at the same time Security protocols use extensive processing power m m C x c o Q c gt e 80 m m C x V c o Q c gt e Option Description Telnet SSH Port Configuration Telnet Port Identifies the TCP IP port used for communications by Telnet with the Rack PDU The default is 23 You can change the Port setting to the number of any unuse
118. ou must also enable DES SSHv2 Enables or disables the following encryption algorithms Block Ciphers Encryption that are compatible with SSH version 2 clients Algorithms 3DES enabled by default The key length is 168 bits Blowfish enabled by default The key length is 128 bits AES 128 The key length is 128 bits AES 256 The key length is 256 bits NOTE Not all SSH clients can use every algorithm Your SSH client selects the algorithm that provides the highest security from among the enabled algorithms that it is able to use If your SSH client cannot use either of the default algorithms you must enable an AES algorithm that it can use 82 m m C x V c o Q c gt e Option Description SSH User Host Key File Status Filename The Status field Indicates the status of the host key private key In the control console you display host key status by selecting Advanced SSH Configuration SSH Disabled No host key in use No host key has been transferred to the Rack PDU or a host key has been transferred improperly NOTE A host key must be installed to the sec directory of the Rack PDU Generating The Rack PDU is generating a host key because no valid host key was installed in its sec directory Loading A host key is being loaded i e being activated on the Rack PDU Valid The host key is valid If you install an invalid host key
119. oups 2 Under Configured Outlet Groups click on the number or name of the outlet group to edit or delete 3 When editing an outlet group you can do any of the following Rename the outlet group Add or remove outlets by clicking the check boxes to mark or unmark them You cannot remove an outlet from an outlet group that contains only two outlets unless the remaining outlet is a Note global outlet 4 To delete the outlet group click Delete Outlet Group 38 m m C x c o Q c gt e Typical outlet group configurations The following configuration shows two Switched Rack PDUs each with eight outlet groups Each outlet group consists of a single global outlet Each outlet group O on the first Switched Rack PDU is linked to the outlet group in the same location on the second Switched Rack PDU One power cord of a dual corded server is connected to each outlet on the first Switched Rack PDU and its other cord is connected to the corresponding outlet on the second Switched Rack PDU ensuring that output power from both power sources to the server will turn on or off in a synchronized manner in response to an outlet control action 39 The following configuration shows three sets of synchronized outlets Global outlets are shown in black Outlet groups are enclosed in red rectangles These four global outlet groups synchronize a total of 19 outlets These two global outl
120. ow to Configure Individual Events lee 68 I m m D I U v c Y baat gt WY Data Menu Web Interface Only 69 Log Optio iba EG RARE SEGRE ED aad ddp d eee d 69 Configuration Optio o 61 45 44 ACACACAC CAD WR Bad aera whee Aa 70 Network Menu 71 Introduction 25533355 32222523 EEX33 AAERXRRG 71 Option Settings a 1 x ARR taa Baa WON OEE CR aes CAD AUR GR 73 System Menu 96 AtKOGUCHION ccdd a RR E C E TREES IT Tt TEILTE 96 Option Settings v opea aiat aa B NACE RCAC WU VOR OR oe aes CAD ADR RC 98 Boot Mode 110 Introduction 51 555553 222 4 233 9X3 3432 E ee 110 DHCP Configuration Settings as xac saw URS Em RORCACACRCOR ORA Rn 112 Security 117 Security Feat res s da hance owe ann ee ee ee RR RR RE UR 117 Eneryption sap 909 REC Sei ae ORO RA eee aa RR 122 Creating and Installing Digital Certificates 126 Firewalls auk sk A AERUERAARRG WEE RR R33 OO Owe wee 133 Using the APC Security Wizard 134 OVervIeW i53 deka 39 4 GR RUSO EUER ADR E E onc mU Dea EAS 134 Create a Root Certificate amp Server Certificates 137 Create a Server Certificate and Signing Request 142 Create an SSH Host Key au iioacuex sch RR RR RU RR RE wd 146 APC Device IP Configuration Wizard 148 Purpose and Requirements llle 148 Install the Wizard emm mmn n 149 Use the Wizard zcc kraasaa ae BLUR at OS OR Credo de ed 150 How to Export C
121. pc To set User Name and Password values for the four account types see User Manager and Outlet User Manager 4 You must use the Web interface to configure values for the Read Only User and you must use the control console to Note Configure values for an Outlet User m A x UJ A c U U lt Y s WY How to Recover From a Lost Password You can use a local computer a computer that connects to the Rack PDU or other device through the serial port to access the control console 1 Select a serial port at the local computer and disable any service that uses that port 2 Connect the serial cable 990 0144 to the selected port on the computer and to the configuration port at the Rack PDU 3 Run a terminal program such as HyperTerminal9 and configure the selected port as follows 9600 bps 8 data bits no parity 1 stop bit no flow control 4 Press ENTER repeatedly if necessary to display the User Name prompt If you are unable to display the User Name prompt verify the following The serial port is not in use by another application The terminal settings are correct as specified in step 3 The correct cable is being used as specified in step 2 5 Press the Reset button The Status LED will flash alternately orange and green Press the Reset button a second time immediately while the LED is flashing to reset the user name and password to their defaults temporarily
122. r is the selection that best defines the Syslog messages sent by a Rack PDU 5 See aso RFC3164 at www ietf org rfc rfc3164 Q Syslog settings Leave the Syslog settings except the Server IP settings o set to their defaults unless otherwise specified by the Syslog network or system administrator e Uu Setting Definition o n General Settings y Syslog Enables by default or disables the Syslog feature Q Facility Selects the facility code assigned to the Rack PDU s Syslog messages lt U i WY 86 m m ai e V Cz o U lt U s Setting Definition Syslog Server Settings Server IP Domain Name Uses specific IP addresses or domain names to identify which of up to four servers will receive Syslog messages sent by the Rack PDU NOTE To use the Syslog feature at least Server IP Domain Name must be defined for at least one server Port Identifies the user datagram protocol UDP port that the Rack PDU will use to send Syslog messages The default is 514 the number of the UDP port assigned to Syslog Local Priority Severity Mapping Map to Syslog s Priorities Maps each of the severity levels Local Priority settings that can be assigned to System and Rack PDU events to the available Syslog priorities The following definitions are from RFC3164 Emergency The system is unusable Alert Action must be taken immediately Critical Crit
123. r names and passwords is essential to establish basic security for your system Port assignments If a Telnet FTP SSH SCP or Web SSL TLS server uses a non standard port a user must specify the port when using the client interface such as a Web browser The non standard port address becomes an extra password hiding the server to provide an additional level of security The TCP ports for which these servers listen are initially set at the standard well known ports for the protocols To hide the interfaces use any port numbers from 5000 to 32768 User names passwords community names SNMP All user names passwords and community names for SNMP are transferred over the network as plain text A user who is capable of monitoring the network traffic can determine the user names and passwords required to log on to the accounts of the control console or Web interface of the Switched Rack PDU If your network requires the higher security of the encryption based options available for the control console and Web interface be sure to disable SNMP access or set its access to read only Read only access allows you to receive status information and to use SNMP traps Authentication versus Encryption You can select to use security features for the Switched Rack PDU that control access by providing basic authentication through user names passwords and IP addresses without using encryption These basic security features are sufficie
124. re failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to affect significantly its safety or effectiveness In direct patient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances Examples of life support devices The term life support device includes but is not limited to neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for adults and infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U S FDA Hospital grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems APC does not claim that units with these modifications are certified or listed as hospital grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care m m al v Cz o U te U s e 173 m am X U V U
125. rface the navigation menu left frame has the following elements IP address of the Rack PDU Menus to manage the Rack PDU and its components Switched Rack PDU menu with Configuration and Scheduling as options Outlets menu with Control Configuration and Outlet Groups as options Menus to manage the event log data log network connection and system parameters Events menu Data menu Network menu System menu When you log on as a Device Manager or Read Only User the Network and System menus are not displayed Options to NO make any changes are not available for the Read Only User When you log on as an Outlet User the Switched Rack PDU Events Network and System menus are not displayed Logout option Help menu Links menu 29 2 Q ai U V aa U UV te Y gt N Selecting a menu to perform a task To do the following see Switched Rack PDU Settings Configure the overload and low load thresholds for each phase or bank Configure the Overload Outlet Restriction for each phase or bank Set the Name Location and Coldstart Delay for the Rack PDU To do the following see Outlet Settings for Outlets and Outlet Groups Apply power to and remove power from the outlets Set Power On Delay Power Off Delay and Reboot Duration for the outlets Set the names and associated links for the outlets Create enable and use synchronized outlet
126. rint is a long string of alphanumeric characters punctuated by colons A fingerprint is a unique identifier that you can use to further authenticate the server Record the fingerprints to compare with the fingerprints contained in the certificate as displayed in the browser SHA Fingerprint This fingerprint is created by a Secure Hash Algorithm SHA MD5 Fingerprint This fingerprint is created by a Message Digest 5 MD5 algorithm WAP Use this option to disable the default or enable the Wireless Application Protocol WAP WAP is a standard for providing cellular phones pagers and other handheld devices with secure access to e mail and text based Web pages WAP runs on all major wireless networks and is device independent so that it can be used with many phones and handheld devices ISX Protocol control console only Use this option to enable the default or disable the APC InfraStruXure ISX Protocol The APC InfraStruXure ISX Protocol allows the Switched Rack PDU to communicate with other APC devices including the InfraStruXure Manager if your system includes one 95 Introduction Overview Use the System menu to do the following tasks Configure system identification date and time settings and Administrator Read Only User Device manager and Outlet User access Centrally administer remote access for each Rack PDU by using RADIUS Remote Authentication Dial in User Service Synchronize
127. s DHCP amp BOOTP The Rack PDU will attempt to get its TCP IP settings from a BOOTP server first and then if it cannot discover a BOOTP server from a DHCP server An After IP Assignment setting by default will switch Boot mode from its default DHCP amp BOOTP setting to BOOTP only or DHCP only depending on the type of server that supplied the Note TCP IP settings to the Rack PDU For information about the After IP Assignment setting and other settings that affect how the Rack PDU uses BOOTP and DHCP see Advanced settings Advanced settings The boot mode affects which settings are available Two settings are available for all Boot mode selections to define the Rack PDU s Host Name and Domain Name values Host Name When an Administrator configures a host name here and a domain name in the Domain Name field users can then enter a host name in any field in the Switched Rack PDU interface except e mail addresses that accepts a domain name as input Domain Name An Administrator needs to configures the domain name here only In all other fields in the Switched Rack PDU interface except e mail addresses that accept domain names the 74 m m ai e Y Cz o U lt U s Rack PDU will add this domain name when only a hostname is entered To override the expansion of a specified host name by the addition of the domain name do one of the following Note To override the behavior in al
128. s Resolution Protocol ARP request it assumes that there is a problem with its network interface and restarts itself Resetting the network timer To ensure that the Rack PDU does not restart if the network is quiet for 9 5 minutes the Rack PDU attempts to contact the Default Gateway every 4 5 minutes If the gateway is present it responds to the Rack PDU and that response restarts the 9 5 minute timer If your application does not require or have a gateway specify the IP address of a computer that is running on the network most of the time and is on the same subnet The network traffic of that computer will restart the 9 5 minute timer frequently enough to prevent the Rack PDU from restarting m m ai e V Cz o U lt U s e Control Console How to Log On Overview You can use either a local serial connection or a remote Telnet or SSH connection to access the control console Use case sensitive User Name and Password entries to log on by default apc and apc for an Administrator or device and apc for a Device Manager A Read Only User has no access to the control console If you cannot remember your user name or password see How to Recover From a Lost Password There is no default password for Outlet User accounts An Administrator must define the password and other account characteristics for an Outlet User See Outlet User Manager m m am MN U V U Q C UJ bam gt
129. s network assignment TCP IP settings from a DHCP server only For more information about the After IP Assignment see Switched Rack PDU settings Following in hexadecimal format is an example of a Vendor Specific Information option that contains the APC cookie and the disable Boot Mode Transition setting Option 43 0x01 0x04 0x31 0x41 0x50 0x43 0x02 0x01 0x01 115 m m al MN U V U Q C im Lo gt WY TCP IP options The Switched Rack PDU uses the following options within a valid DHCP response to define its TCP IP settings IP Address from the yiaddr field of the DHCP response Provides the IP address that the DHCP server is leasing to the Rack PDU Subnet Mask option 1 Provides the subnet mask value needed by the Rack PDU to operate on the network Default Gateway option 3 Provides the default gateway address needed by the Rack PDU to operate on the network Address Lease Time option 51 Identifies the length of time for the lease associated with the identified IP Address Renewal Time T1 option 58 Identifies how long the Rack PDU must wait after an IP address lease is assigned before it can request a renewal of that lease Rebinding Time T2 option 59 Identifies how long the Rack PDU must wait after an IP address lease is assigned before it can seek to rebind that lease Miscellaneous options The Switched Rack PDU uses the following options within a valid DHCP respo
130. s of the outlets you want to modify or select the All Outlets check box Enter values for Name and Link and click the Apply button immediately below the list Control Console To configure the outlet settings and outlet name 1 Select Outlet Control Configuration from the Device Manager menu 2 Choose the number of the outlet you want to control and press ENTER 3 Choose Configure Outlet to display and change the values for Outlet Name Power On Delay Power Off Delay and Reboot Duration 45 m m C x V c o Q c gt e Switched Rack PDU Settings Configure Load Thresholds W eb interface 1 Select Switched Rack PDU from the navigation menu 2 Click Configure in the Load Management section 3 Set Overload Alarm Threshold Near Overload Warning Threshold Low Load Warning Threshold and Overload Outlet Restrictions for each phase or bank 4 Click Apply in that section to set the selected values Control console 1 From the Device Manager menu select Phase Bank Monitor Configuration 2 Select a phase or bank for 3 phase units 3 Select Overload Alarm Threshold amps Near Overload Warning Threshold amps or Low Load Warning Threshold amps 4 Select Accept Changes To set the overload outlet restriction select Outlet Restriction Configuration on the Device manager menu For 3 phase units select a phase or bank to display and change the Outlet Phase Bank Restrict
131. s remotely Prepare to configure the settings Before you run the Wizard be sure that you have the information you will need during the configuration procedure 1 Contact your network administrator to obtain valid TCP IP settings to use 2 If you are configuring multiple unconfigured Network Management Cards obtain the MAC address of each one so that you can identify each Network Management Card that the Wizard discovers The Wizard displays the MAC address for a discovered card on the same screen on which you then enter the TCP IP settings For Network Management Cards that you install the MAC address is on a label on the bottom of the card For embedded Network Management Cards the MAC address is on a label on the device containing the card for example usually on the side of a device that you mount in a rack You can also obtain the MAC address from the Quality Assurance slip that came with the Network Management Card or with the device containing an embedded Network Management Card m m C x c o Q c gt e 150 m m ai e V Cz o U lt U s e Run the Wizard to perform the configuration To discover and configure over the network installed or embedded Network Management Cards that are not configured 1 From the Start menu launch the Wizard The Wizard automatically detects the first Network Management Card that is not configured Select Remotely o
132. s selected only the configured delays and reboot duration of the lowest numbered outlet of the group are used If a global outlet group is selected only the configured delays and reboot duration of the global outlet are used 43 m m al MN U V U Q C im bam gt WY How to configure outlet settings and outlet name Settings that you can configure The following settings are available in both the Web interface and control console unless otherwise indicated Setting Description Power On Delay Set the number of seconds that the Rack PDU waits after a command is issued before applying power to an outlet NOTE To configure an outlet to remain off at all times check the Never check box next to Power On Delay in the Web interface or configure a value of 1 for Power On Delay in the control console Power Off Delay Set the number of seconds that the Rack PDU waits after a command is issued before removing power from an outlet NOTE To configure an outlet to remain on at all times check the Never check box next to Power Off Delay in the Web interface or configure a value of 1 for Power Off Delay in the control console Reboot Duration Set the number of seconds an outlet remains off before restarting Name Web Set the name for one or more outlets The name is displayed next interface to the outlet number on status screens Outlet Name control console Link We
133. s that have been recorded since the log was last deleted in reverse chronological order Use the SPACE BAR to scroll through the recorded events While viewing the log type d and press ENTER to clear all events from the log m m ai e V Cz o U lt U s After events are deleted they cannot be retrieved Note 56 How to use FTP or SCP to retrieve a log file If you are using the encryption based security protocols for your system use Secure CoPy SCP to retrieve the log file You should have FTP disabled If you are using unencrypted authentication methods for the security of your system use FTP to retrieve the log file Note See Security for information on the available protocols and methods for setting up the type of security appropriate for your needs If you have Administrator or Device Manager access you can use SCP or FTP to retrieve a tab delineated event log file event txt or data log file data txt that you can import into a spreadsheet application The file reports all of the events or data recorded since the log was last deleted The file includes information that the event log or data log does not display The version of the file format first field The Date and Time the file was retrieved The Name Contact and Location values and the IP address of the Rack PDU The unique Event Code for each recorded event event txt file only The Rack PDU uses a 4 di
134. ser can validate the server certificate of the Rack PDU e Create a server certificate which is stored in a file with a p15 extension During this task you are prompted for the CA root certificate that signs the server certificate Load the server certificate onto the Switched Rack PDU For each Switched Rack PDU that requires a server certificate repeat the tasks that create and load the server certificate m m ai e V Cz o U lt U s e 137 m m ai e v Cz o U lt U s e The procedure Create the CA root certificate Perform these steps Click Next to move from screen to screen 1 If the APC Security Wizard is not already installed on your computer install it by running the installation program APC Security Wizard exe from the APC Rack PDU Utility CD that came with your Rack PDU On the Windows Start menu select Programs then APC Security Wizard to start the Wizard program On the screen labeled Step 1 select CA Root Certificate as the type of file to create Enter a name for the file that will contain the Certificate Authority s public root certificate and private key The file name must have a p15 extension By default the file will be created in the installation folder C Program Files American Power Conversion APC Security Wizard On the screen labeled Step 2 provide the information to configure the CA root certificate The Country and
135. setting or DHCP only eS For more details on DHCP and DHCP options see RFC2131 and RFC2132 See also m m al MN U V U Q C im bam gt WY 110 DHCP amp BOOTP boot process When Boot mode is set to its default DHCP amp BOOTP setting the following occurs when the Switched Rack PDU is started or reset 1 The Rack PDU makes up to five requests for its network assignment from any BOOTP server If a valid BOOTP response is received the Rack PDU starts the network services and sets Boot mode to BOOTP Only 2 If the Rack PDU fails to receive a valid BOOTP response after five BOOTP requests the Rack PDU makes up to five requests for its network assignment from any DHCP server If a valid DHCP response is received the Rack PDU starts the network services and sets Boot mode to DHCP Only To configure the Switched Rack PDU so that it always uses the DHCP amp BOOTP setting for Boot mode enable the Remain in DHCP amp BOOTP mode after accepting TCP IP settings option which is disabled by default See Switched Rack PDU settings 3 If the Switched Rack PDU fails to receive a valid DHCP response after five DHCP requests it repeats BOOTP and DHCP requests until it receives a valid network assignment First it sends a BOOTP request every 32 seconds for 12 minutes then one DHCP request with a time out of 64 seconds and so forth APC Cookie the Switched Rack PDU accepts the lease from that server
136. sion and contains the Rack PDU S private key and the public key obtained from the cer or crt file Load the server certificate to the Rack PDU Perform these steps 1 On the Network menu of the Web interface of the Switched Rack PDU select the Web SSL option 2 In the SSL TLS Server Certificate section of the page browse to the server certificate the p15 file you created in the procedure Import the signed certificate The default location is C Program Files American Power Conversion APC Security Wizard Alternatively you can use FTP or Secure CoPy SCP to transfer the server certificate to the Rack PDU If you use FTP or SCP for the transfer you must specify the correct location sec on the Rack PDU For SCP the command to transfer a certificate named cert p15 to a Rack PDU with an IP address of 156 205 6 185 would be Note scp cert pl5 apc 156 205 6 185 sec cert p15 a C x V c o Q c gt e 145 Create an SSH Host Key Summary This procedure is optional If you select SSH encryption but do not create a host key the Switched Rack PDU generates a 768 bit RSA key when it reboots Host keys for SSH that are created with the APC Security Wizard are 1024 bit RSA keys Use the APC Security Wizard to create a host key which is encrypted and stored in a file with p15 extension Load the host key onto the Rack PDU The procedure Create the host key Perform these steps Click
137. substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which vary according to jurisdiction a Q d Cc IT v m m m al V cz o U te gt e 2 Q ai U V aa U UV te Y gt N Obtaining service To obtain support for problems with your Switched Rack PDU 1 Note the serial number and date of purchase For the serial number see the About System menu option or the label on the bottom of the unit Contact Customer Support at a phone number located at the end of this manual A technician will try to help you solve the problem by phone If you must return the product the technician will give you a return material authorization RMA number If the warranty expired you will be charged for repair or replacement Pack the unit carefully The warranty does not cover damage sustained in transit Enclose a letter with your name address RMA number and daytime phone number a copy of the sales receipt and a check as payment if applicable Mark the RMA number clearly on the outside of the shipping carton Ship by insured prepaid carrier to the address provided by the Customer Support technician 172 Life Support Policy General policy American Power Conversion APC does not recommend the use of any of its products in the following situations In life support applications whe
138. t amps for the phase or bank indicated by the illuminated Load Indicator LED On 3 phase units the Digital Display will cycle through the phases or banks displaying the current for each for 3 seconds If an internal communication failure or power supply failure occurs for either a 1 or 3 phase model the Digital Display displays Er which you can clear by pressing the input selector Q Reset Button Resets the Rack PDU without affecting the outlet status Link RX TX 10 100 LED This LED indicates the network status Condition Description Off The device that connects the Rack PDU to the network is off or not operating correctly Flashing Green The Rack PDU is receiving data packets from the network at 10 Megabits per second Mbps Flashing Orange The Rack PDU is receiving data packets from the network at 100 Megabits per second Mbps Solid Green or The Rack PDU is not receiving any network traffic Orange m m C x V c o Q c gt e Status LED This LED indicates the network status of the Rack PDU Condition Description Off The Rack PDU has no power Solid Green The Rack PDU has valid TCP IP settings Flashing Green The Rack PDU does not have valid TCP IP settings Solid Orange A hardware failure has been detected in the Rack PDU Contact APC Worldwide Customer Support Flashing Orange The Rack PDU is making BOOTP requests
139. t the user name and password are transmitted as plain text SSH disables Telnet and provides encrypted access to the control console interface to provide additional protection from attempts to intercept forge or alter data during data transmission m m C x V c o Q c gt e SNMP Security Access Description Available methods Community Name Domain Name NMS IP filters Agent Enable Disable 4 access communities with read write disable capability The domain name restricts access only to the NMS as that location and the NMS IP filters allow access only from designated iP addresses 162 245 12 1 allows only the NMS with that IP address to have access 162 245 12 255 allows access for any NMS on the 162 245 12 segment 162 245 255 255 allows access for any NMS on the 162 245 segment 162 255 255 255 allows access for any NMS on the 162 segment 0 0 0 0 or 255 255 255 255 allows access for any NMS File transfer protocols Security Access Description Available methods User name and password Selectable server port Server Enable Disable Secure CoPy SCP With FTP the user name and password are transmitted as plain text and files are transferred without the protection of encryption Using SCP instead of FTP encrypts the user name and password and the files being transferred such as firmware updates configura
140. than 64 characters in length and is exported to its root directory ftp put filename ini Exporting the file to multiple Rack PDUs To export the ini file to multiple Switched Rack PDUs Use FTP or SCP but write a script that incorporates and repeats the steps used for exporting the file to a single Management Card e Use a batch processing file and the APC ini file utility To create the batch file and use the utility see Release Notes ini File Utility version 1 0 doc en ininotes pdf on the APC See also Rack PDU Utility CD that came with your Rack PDU 157 m m ai e V Cz o U lt U s e The Upload Event and Error Messages The event and its error messages The following system event occurs when the receiving Switched Rack PDU completes using the ini file to update its settings Configuration file upload complete with number valid values This event has no default severity level If a keyword section name or value is invalid the event text is extended to include notification of the following errors Q The export to and the subsequent upload by the receiving Rack PDU succeeds even if there are errors Note Event text Description Configuration file warning Invalid A line with an invalid keyword or value is ignored keyword on line number Configuration file warning Invalid value on line number Configuration file warning Invalid If a section name is invalid all
141. the current value for that parameter s setting either the default value if the value has not been specifically configured or the configured value The Override keyword with its default value prevents one or more keywords and their device specific values from being exported In the NetworkTCP IP section the default value for Override the MAC address of the Rack PDU blocks the exporting of the values for the keywords SystemIP SubnetMask DefaultGateway and BootMode You must edit the section SystemDate Time if you want to set the system date and time of a receiving Rack PDU or cause that Rack PDU to use an NTP Server to set its date and time See Customizing for configuration guidelines for date and time settings 154 m m C x V c o Q c gt e Detailed procedures Use the following procedures to retrieve the settings of one Switched Rack PDU and export them to one or more other Switched Rack PDUs Retrieving To set up and retrieve an ini file to export 1 Configure a Rack PDU with the settings you want to export To avoid errors configure the Rack PDU by using its Web interface or control console whenever possible Directly Note editing the ini file risks introducing errors 2 Use FTP to retrieve the file config ini from the Rack PDU you configured a Open a connection to the Rack PDU using its IP Address For example ftp open 158 165 2 132 b Log on using the Administra
142. the default for User Name and apc is the default for Password 58 E m A aa U t v c Y ad gt V 3 Use the get command to transmit the text version of the event or data log to your local drive ftp gt get event txt or ftp gt get data txt 4 You can use the del command to clear the contents of the event or data log ftp gt del or ftp gt del event txt data txt Q You will not be asked to confirm the deletion Note If you clear the data log a Deleted Log event will be recorded in the Event Log f you clear the event log a new event txt file will be created to record the Deleted Log event 5 Type quit at the t p prompt to exit from FTP 59 2 Q ai U V aa U UV te Y gt N Event Actions Web Interface Only Overview The Actions option is available only on the Web interface s Events menu This option allows you to select which actions will occur for events that have a specified severity level Event Log selects which severity levels cause an event to be recorded in the event log See Event log action Syslog selects which severity levels cause messages to be sent to Syslog servers to log events See Syslog action SNMP Traps selects which severity levels cause SNMP traps to be generated Click Details to access a complete list of the System embedded management card and Device Rack PDU events that can occur
143. thority you must load a root certificate individually into the certificate store cache of each user s browser Browser manufacturers already provide root certificates for commercial Certificate Authorities in the certificate store within the browser See Method 3 130 Method 3 Use the APC Security Wizard to create a certificate signing request to be signed by the root certificate of an external Certificate Authority and to create a server certificate Use the APC Security Wizard to create a request a csr file to send to a Certificate Authority The Certificate Authority returns a signed certificate a crt file based on information you submitted in your request You then use the APC Security Wizard to create a server certificate a p15 file that includes the signature from the root certificate returned by the Certificate Authority Upload the server certificate to the Rack PDU its own Certificate Authority Use the APC Security Wizard in the same way but use your own Certificate Authority in place of a commercial Certificate Authority You can also use Method 3 if your company or agency operates Note This method has the following advantages and disadvantages Advantages Before they are transmitted the user name and password for Rack PDU access and all data to and from the Rack PDU are encrypted You have the benefit of authentication by a Certificate Authority that already has a signed root certificate in t
144. tings for Outlets and Outlet Groups How to initiate a control action If you apply an outlet control action to outlets or outlet groups the following delays are used for the action Note e For an individual outlet not in an outlet group the action uses the delay periods and reboot duration configured for that outlet For a global outlet group the action uses the delay periods and reboot duration configured for the global outlet Fora local outlet group the action uses the delay periods configured for the lowest numbered outlet in the group W eb interface To control the outlets on your Switched Rack PDU 1 Select Outlets and then Control on the navigation menu 2 Mark the check boxes for each individual outlet or outlet group to control or select the All Outlets check box 3 Select a Control Action from the list and click Next gt gt On the confirmation page that explains the action choose to execute or cancel it Control Console Select Outlet Control Configuration from the Device Manager menu to display a list of outlets For each outlet the list indicates whether it is a member of an outlet group 1 Choose either or the following To control one outlet and the outlet group if any to which it belongs select the number of the outlet and then select Control Outlet To control all outlets select Master Control Configuration and then Control of ALL Outlets 2 Select a control action 3 On the confirmati
145. tion files log files Secure Sockets Layer SSL certificates and Secure SHell SSH host keys If you choose SCP as your file transfer protocol enable SSH and disable FTP m m C x V c o Q c gt e W eb Server Security Access Description Available methods User name and password Selectable server port Server Enable Disable Secure Sockets Layer SSL and Transport Layer In basic HTTP authentication mode the user name and password are transmitted base 64 encoded with no encryption SSL and TLS are available on Web browsers supported for the Switched Rack PDU and on most Web servers The Web protocol Hypertext Transfer Protocol over Security TLS Secure Sockets Layer HTTPS encrypts and decrypts page requests to the Web server and pages returned by the Web server to the user RADIUS Security Access Description Available methods Centralized authentication of access rights A server secret shared between the RADIUS server and the Rack PDU RADIUS Remote Authentication Dial In User Service is an authentication authorization and accounting service used to centrally administer remote access for each Rack PDU Changing default user names and passwords immediately As soon as you complete the installation and initial configuration of the Rack PDU immediately change the default user names and passwords Configuring unique use
146. tor user name and password configured for the Rack PDU c Retrieve the config ini file containing the Rack PDU s current settings ftp get config ini The file is written to the folder from which you launched FTP To create batch files and use an APC utility to retrieve configuration settings from multiple Rack PDUs and export them to other Rack PDUs see Release Notes ini File Utility version 1 0 See also doc en ininotes pdf on the APC Rack PDU Utility CD that came with your Rack PDU 155 m m am MN U V U Q C UJ Lo gt WY Customizing You must customize the file to change at least the TCP IP settings before you export it 1 Use a text editor to customize the file Section headings keywords and pre defined values are not case sensitive but string values that you define are case sensitive Use adjacent quotation marks to indicate no value For example LinkURL1 indicates that the URL is intentionally undefined To define values opening and closing quotation marks are optional except to enclose values that contain leading or trailing spaces or values which are already enclosed in quotation marks Leading or trailing spaces not within the opening and closing quotation marks are ignored To export a specific system date and time or any scheduled events you must configure the values directly in the ini file To export a specific system time export only the configured System
147. trol console 21 Host keys creating 146 filename 83 file status 83 fingerprints displaying for versions 1and2 84 generated by the PDU 79 transferring to the PDU 79 83 Host Name setting 74 112 HTTP Port 91 HTTP protocol mode 90 HTTPS Port 91 HTTPS protocol mode 90 Hyperlinks defining 108 Identification fields on main screen 19 InfraStruXure Manager 1 2 Q ai U V aa U UV te Y gt N ini files See User configuration files Initiator outlet groups 33 IP addresses of DNS server for e mail 64 of trap receivers 63 to limit access to specified NMSs 85 K keywords user configuration file 154 L Life support policy 173 Link as an outlet setting 44 Links redirecting user definable links 32 Local outlet groups 33 creating 37 Local SMTP server 67 Lock icon indicating SSL is enabled 90 Logging on control console 15 Web interface 24 Login date and time control console 19 Web interface 27 M Main screen displaying identification 19 firmware values displayed 19 login date and time 19 status 20 Up Time 19 User access identification 19 177 Manual boot mode setting 74 Menus Control Console 22 Data 30 69 event related 30 Events 30 Help 31 Links 108 Network 31 System 31 Web interface 29 N Network menu DNS 76 Email 85 FTP Server 77 ISX Protocol 95 Ping utility 77 SNMP 84 Syslog 86 TCP IP 73 Telnet SSH 78 WAP 95 Web SSL 88 NMS IP setting Domain Name Setting 85 O O
148. ure the basic TCP IP settings of installed or embedded Network Management Cards in either of the following ways Automatically discover and configure unconfigured Network Management Cards remotely over your TCP IP network Configure or reconfigure a Network Management Card through a direct connection from the serial port of your computer to the device that contains the card The Wizard can discover and configure Network Management Cards only if they are on the same network segment as the Note Computer that is running the Wizard System requirements The Wizard runs on Windows NT Windows 2000 Windows 2003 and Windows XP Intel based workstations m am X U V U U C im gt ua 148 E m A aa U t v c Y ad gt V Install the Wizard Automated installation If autorun is enabled on your CD ROM drive the installation program starts automatically when you insert the CD Manual installation If autorun is not enabled on your CD ROM drive run setup exe in the Wizard directory on the CD and follow the on screen instructions You can also download the latest version of the APC Device IP Configuration Wizard from the APC Web site www apc com and run setup exe from the folder to which you downloaded it 149 Use the Wizard Launch the Wizard The installation creates a shortcut link in the Start menu that you can use to launch the Wizard Configure the basic TCP IP setting
149. ver the network and click Next gt 3 Enter the TCP IP settings System IP Subnet Mask and Default Gateway for the unconfigured Network Management Card identified by the MAC address at the top of the screen Then click Next gt On the Transmit Current Settings Remotely screen if you check mark Start a Web browser when finished the default Web browser connects to the device that contains the Network Management Card after you transmit the card s settings Click Finish to transmit the TCP IP settings If the IP address you entered is in use on the network the Wizard prompts you to enter an IP address that is not in use Enter a correct IP address and click Finish The Wizard searches for another installed or embedded but unconfigured Network Management Card If it finds one it displays the screen with data entry boxes for the TCP IP settings of that card To skip configuring the card whose MAC address is currently displayed click Cancel To configure the TCP IP settings of the next card repeat this procedure beginning at step 4 151 Configure or reconfigure the TCP IP settings locally To configure a single Network Management Card through a serial connection 1 Contact your network administrator to obtain valid TCP IP settings 2 Connect the serial configuration cable that came with the Network Management Card or with the device that contains an embedded Network Management Card a Connect one
150. without a Certificate Authority 137 Severity levels of events 61 events with no severity level 61 mapping event severity to Syslog priorities 87 Signing requests creating 142 SMTP From Address 65 Server 65 server 67 SMTP Server 65 SNMP Access Type setting 85 Authentication Traps 63 Community Name setting 84 NMS IP Domain Name setting 85 SNMP traps option 62 SSH enabling 78 encryption 122 fingerprints displaying and comparing 79 host key as identifier that cannot be falsified 122 creating 146 fille name 83 file status 83 transferring to the PDU 79 modifying the Port setting 81 91 obtaining an SSH client 79 server configuration 82 v1 Encryption Algorithms 82 v2 Encryption Algorithms 82 SSL m m ai e V Cz o U lt U s e authentication through digital certificates 124 certificate signing requests 125 encryption ciphers and hash algorithms Status in Web interface 27 on control console main screen 20 Syslog defining Server IP addresses domain names 87 enabling and disabling 86 Facility setting 86 message format 88 sending atest message 87 setting the UDP port 87 Syslog setting 86 System information obtaining 31 System menu About System in control console 108 Date amp Time 105 Identification 105 Links 108 Modem not supported 108 Outlet User Manager 99 RADIUS 101 settings 102 Tools 107 User Manager 98 System requirements outlet groups 35 T TCP IP Boot
151. y TCP IP to Defaults 107 to Defaults 107 to Defaults Except TCP IP 107 Retry Then Fail setting 75 Retry Then Stop setting DHCP 113 Reverse DNS Lookup 77 Root certificates creating 137 S Scheduling outlet events 49 SCP enabled and configured with SSH 78 m m ai e V Cz o U lt U s e 123 Secondary NTP Server 106 Secondary Server for RADIUS 102 Secondary Server Secret for RADIUS 102 Section headings user configuration file 154 Secure CoPy See SCP Secure Hash Algorithm SHA 92 Secure SHell See SSH Secure Sockets Layer See SSL Security authentication authentication vs encryption 120 through digital certificates with SSL 124 certificate signing requests 125 disabling less secure interfaces 123 encryption with SSH and SCP 122 how certificates are used 134 How SSH host keys are used 135 immediately changing username and password 119 options for each interface 117 planning and implementing 117 120 SCP as alternative to FTP 123 SSL choosing a method to use certificates 126 CipherSuite algorithms and ciphers 125 supported SSH clients 79 using non standards ports as extra passwords 120 Security Wizard 134 creating certificates without a Certificate Authority 137 creating server certificates to use with a Certificate Authority 142 creating signing requests 142 creating SSH host keys 146 179 Send DNS Query 76 Server certificates creating to use witha Certificate Authority 142 creating
152. you could schedule a one time event on any date from the current date until June 3 2005 5 Use the check boxes to select which outlets will be affected by the action You can select one or more individual outlets or All Outlets 6 Click Apply to confirm the scheduling of the event or Clear to cancel it When you confirm the event the summary page is re displayed with the new event displayed in the list of scheduled events 51 2 Q ai U V aa U UV te Y gt N How to edit disable enable or delete an outlet event 1 2 From the menus of the Web interface select Switched Rack PDU and then Scheduling In the event list in the Summary section of the Outlet Scheduling page click on the name of the event On the Scheduled Event Details page you can do any of the following Change details of the event such as the name of the event when it is scheduled to occur and which outlets are affected Under Status of event at the bottom of the page e Disable the event leaving all its details configured so that it can be re enabled later A disabled event will not occur An event is enabled by default when you create it e Enable the event if it was previously set to Disable e Delete the event removing the event completely from the system A deleted event cannot be retrieved Click Clear at any time to cancel your changes to the event Using Clear cancels only the changes you made
153. ystem you can use FTP or SCP to transfer the individual AOS and application firmware modules For a Switched Rack PDU that is not on your network you can use XMODEM through a serial connection to transfer the individual AOS and application firmware modules from your computer to the Switched Rack PDU When you transfer individual firmware modules and do not use the automated firmware upgrade tool to upgrade the firmware for a Rack PDU you must transfer the APC Note Operating System AOS module to the Rack PDU before you transfer the application module For more information about the firmware modules see Firmware files Switched Rack PDU 165 Use FTP or SCP to upgrade one Rack PDU Instructions for using FTP For you to be able to use FTP to upgrade a single Switched Rack PDU over the network The Switched Rack PDU must be connected to the network The FTP server must be enabled at the Switched Rack PDU The Switched Rack PDU must have its TCP IP settings System IP Subnet Mask and Default Gateway addresses configured To use FTP to upgrade the Rack PDU 1 Open an MS DOS command prompt window on a computer that is connected to the network Go to the directory that contains the firmware upgrade files and list the files For the directory C apc the commands would be those shown in bold C gt ed ape C Napc dir Files listed for a Switched Rack PDU for example might be the following apc hw02 aos