1. FIG 1 6 Using extra bracket figure 1 rotate roller bracket assembly until it is in position as in figure 2 Be sure power is disconnected 7 Push new tubing into inlet port FIG 2 anchoring the tubing in grippers see figure 3 If using 9 piece of tube 1 1 2 should be extended outside of inlet port 8 Continue to rotate the roller bracket assembly using the extra bracket FIG 3 while pushing the tubing into the roller race figure 4 9 Insert the tubing into the outer port figure 5 and replace the cover and SCrews FIG 4 FIG 5 PROCEDURE C Without removing the pump cover run the entire unit at high RPM Pull the old tubing out from outlet port pump Install new tube by inserting into inlet port continue feeding tube 1 4 in at a time allowing the roller assembly to push tubing through When tubing is half INLET PORT way around the race put your finger over the inlet hole of the tube and continue to feed tubing 1 4 at a time this should make installation easier Continue until desired tubing extension is obtained Run unit for about one minute OUTLET PORT WARNING ANKO PRODUCTS INC assumes no responsibility or liability for chemical compatibility of our tubing in specific applications ALWAYS pretest tubing in accordance with tubing manufacture s specifications Tubing that shows signs of swelling embrittlement or other deterioration should not be used ROLLER B
2. RETURN AND REPAIR REQUESTS Please direct all warranty requests to the appropriate distributor the product was purchased from The MITYFLEX 907 and 908 models are fixed speed general purpose pumps for dispensing fluid based on products The 907 is housed in a case and is controlled by a simple on off switch that activates the pump The 908 is manufactured with a zinc plated steel bracket and six inch lead wires for convenient assembly to your OEM application FEATURES 1 ELECTRICAL 115 VAC 60HZ OPTIONS 24 to 240 VAC 50Hz 60Hz or 50 60Hz 12 amp 24 VDC The 907 also includes On Off switch 6 foot power cord 2 PRIMING Unit is self priming and will hold vacuum when off 3 OPERATION Pump can run dry without damaging the motor or drive unit however the tubing life will be reduced 4 CONSTRUCTION Polypropylene housing and case using stainless steel fasteners 5 MAX HEAD PRESSURE Maximum working pressure 40 PSI 6 MAX SUCTION LIFT 29 feet 8 8m with H20 Zi RATING AC Units 100 of continuous operation at 25 C ambient DC Units 100 continuous operation at 40 C ambient 8 FLOW RATE 4 987 ml min Depending on the tubing used See page 5 FUSE 907 only Located on the exterior of the case See page 6 for replacement procedure and page 5 for fuse type INSTALLATION INSTRUCTIONS 1 POWER REQUIREMENTS Voltage and frequency of power supply must be the same as shown on unit WIRING CONNECTIONS All wi
3. from the date of delivery from our factory or authorized distributor It is limited to repairing or replacing any device or part of any device which is returned transportation prepaid to the factory within one year of delivery to the original purchaser and which is proven to be defective upon examination by us ANKO PRODUCTS INC disclaims all liability for consequential damage of whatever nature damage of equipment during transportation damage damage due to improper handling installation or improper operation or for determining suitability for the particular use intended by a purchaser Replaceable parts including tubes supplied with the product are not covered by any warranties either expressed or implied ANKO PRODUCTS INC makes no warranties either express or implied including implied warranty or merchantability other than those stated above No representative has authority to change or modify this warranty in any respect Jurisdiction and venue for enforcement of this warranty may be brought only in the State of Florida This warrant gives you specific legal rights and you may also have other rights which vary from state to state WARNING ANKO PRODUCTS INC assumes no responsibility or liability for chemical compatibility of our tubing in specific applications ALWAYS pretest tubing in accordance with tubing manufacturer s specifications Tubing that shows signs of swelling embrittlement or other deterioration should not be used
4. RACKET ASSEMBLY INSTRUCTIONS For Roller Replacement A plastic roller bracket assembly is supplied with units ranging from 2 to 108 RPM No assembly is required for the plastic bracket If new rollers are required a new assembly must be ordered 1 To remove the roller bracket assembly from the pump use a flat head screwdriver and pry open both sides of the springs to the edge of the bracket Pull the roller bracket assembly off the shaft holding on to the roller area of the bracket Holding the top and bottom of the bracket slide the spring off to the side and lay the assembly on a flat surface Try not to let it fall apart as you will need to put it together the same way it is now Remove the top bracket and the rollers If a roller pin comes out of its recess replace it at this time Place the new rollers on the pins and replace the top bracket Be sure that the flat in the inner hole of the top bracket lines up with the flat on the bottom bracket Slide the spring fastener back over the bracket Do not snap the spring together Matching the roller bracket flat to the output shaft flat slide the roller bracket assembly down until it stops without using force Snap the spring together SPRING BOTTOM BRACKET ROLLERS TOP BRACKET NOTE THE FLATS ON THE BRAGKETS MUST ALWAYS LINE UP Illustration of the pump assembly Fan Screw 1 8 32 x 7 8 Gearmotor Mounting Bracket 908 only Pump Ho
5. SM ITYFLEX nc PUMPS PERISTALTIC PUMP OWNERS MANUAL 907 amp 908 SERIES QUALITY MANAGEMENT SYSTEM REGISTERED TO IS09001 INTERNATIONAL STANDARDS NKO ANKO PRODUCTS INC PUMP DIVISION www ankoproducts com Thank you for purchasing an Anko Mityflex Peristaltic pump We are sure you will be completely satisfied with its performance Should you need assistance or have questions regarding the use or installation please visit our website at www ankoproducts com TABLE OF CONTENTS WARRANTY WARNING RETURN AND REPAIR PUMP FEATURES PUMP INSTALLATION FLOW CHARTS ROLLER SELECTION FUSE INSTALLATION FAN ASSEMBLY TUBING INSTALLATION TUBING INSTALLATION PROCEDURE A TUBING INSTALLATION PROCEDURE B TUBING INSTALLATION PROCEDURE C ROLLER BRACKET ASSEMBLY ILLUSTRATION OF PUMP HEAD ASSEMBLY REPLACEMENT PARTS LIST O CON ND DW HB BW 402 W e he e e e o Every precaution for accuracy has been taken in the preparation of this manual however ANKO PRODUCTS INC neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the products in accordance with the information contained in this manual LIMITED WARRANTY ANKO PRODUCTS INC warrants equipment of its manufacture and bearing its identification to be free from defects in workmanship and material ANKO PRODUCTS INC s liability under this warranty extends for a period of one year
6. oor TUBING INSTALLATION Inspect all tubing regularly and replace if any sign of deterioration occurs Always wear safety glasses and protective clothing when working with chemicals See chart below for proper tubing installation procedure for your unit 00 002 through 90 014 Procedure A below 90 023 through 90 049 Procedure A or B page 6 or 8 90 058 through 90 282 Procedure A or C page 6 or 9 WARNING MODEL 907 002 907 007 907 014 908 002 908 007 and 908 014 GEARTRAINS CAN BE DAMAGED IF DRIVE SHAFT IS ROTATED BY HAND FOR TUBE INSERTION PROCEDURE A If unit is new start with step ff 6 1 Disconnect power to the pump 2 Disconnect the suction and discharge tubing from the pump tubing 3 Remove four screws and pump cover from pump head 4 Pull out old pump tubing and discard B Clean roller race removing and particles that could damage tubing 6 Connect power and run at slowest speed until roller bracket assembly is in position as shown in figure 1 7 Push new tubing into inlet port anchoring tubing in grippers If using a 9 piece of tube 1 1 2 should be extended outside of inlet port figure 2 8 Continue to run at slowest speed carefully feeding tube into race as the rollers turn figure 3 Keep fingers away from rollers 9 Insert tubing into outlet port figure 4 and replace cover PROCEDURE B Follow steps 1 5 in procedure A then continue with the following
7. ring and electrical connections must comply with local and national electrical codes MOUNTING 907 Case enclosed model has rubber feet and mounting flanges This enables it to be used on a flat surface or wall mounted Be sure that one of the sets of vent holes has plenty of air for circulation 908 Mounting brackets for OEM applications Be sure there is plenty of space for air circulation Do not allow tubing to be crimped MOUNTING LOCATION Pump should be placed in a dry location with adequate cooling provided The ambient temperature should not exceed 25 C for AC units or 40 C for DC units WARNING This unit should not be used in outdoor or hazardous locations MODEL 907 FLOW RANGE CHART FLOW RATES ml min FUSE FA ll ED o piia p rmm smm Unte 00 MM Fr Fn gg gt Ep gt gene sam gt EE n e pe ues EN 9050086 Js Jo tw 9071049 Jo Im 98 fm 907058 Ja 49 ttt 1208 905075 16 Je Jaso z3 907108 Ja Ja ne 138 907129 for gt tos 258 142 gt am ux pu ee ee 907208 faa toast 907 282 eo 237 564 1997 sene 12 1116 18 00 Flow rate based on pumping water ar 25 C and 0 PSI using 60 durometer thermoplastic elastomer tubing MODEL 908 FLOW RANGE CHART ml min Tubing 062 In 125 In 187 In 250 In RPMS AMPS E MEINE NEN MEME Unt amp men 1 e la Ms e leuius 908028 e qa 86 198 gt 908036 s qo Im t
8. te M iM INDEM mee m pu pe pmo ge e auem 12 1211161800 MEET wm m us ara io s rms 908 129 for 18 foss Ja eee 22 12005180 908282 60 237 ss for gt 12 1115 18 00 Flow rate based on pumping water ar 25 C and 0 PSI using 60 durometer thermoplastic elastomer tubing ROLLER TUBING SELECTION Use the following color coded rollers with the appropriate tubing I D Your unit is assembled with black rollers Red rollers are included in your tubing kit See separate instructions for roller replacement enclosed in your tube kit Roller Tubing ID ML Revolution Black 1 4 250 3 5 Black 3 16 187 2 1 Red 1 8 125 0 8 Red 1 16 0 21 The 1 16 ID tubing must be inserted into 3 16 187 ID X 3 8 375 OD tubing sleeve for operation in pump FUSE INSTALLATION 907 See page 4 for fuse type and page 10 for fuse ordering information Disconnect power to pump Remove four screws from case front Carefully remove case cover being sure not to pull wires apart Lay the unit on a flat surface Find fuse holder and pull apart Remove old fuse and replace with new fuse EE Ed e per Replace case cover FAN ASSEMBLY See page 4 for replacement number Disconnect the power from the pump The fan is pressed on to the rotor shaft On all 907 case units the fan is pressed on with metal clip away from the motor On all OEM 908 units the fan is pressed on with the metal clip toward the d
9. using Tube Screws 4 10 32 x 1 1 4 Nylon Washer Roller Bracket Assembly 10 Pump Cover 11 Screws 4 8 32 x 5 8 The 908 mounting bracket is replaced with the 907 case cover on the case model Replacement Parts List Contact your local distributor to order Please remember to include the complete model number when you place your order for replacement parts For fan orders use the chart on page 4 for the part number Item Unit Number Plastic Roller Bracket Red RBA 1718 03 25 Plastic Roller Bracket Black RBA 1718 01 25 Black Roller Bracket Assembly RB 1212 01 00 Red Roller Bracket Assembly RB 1212 03 00 Pump Kit 907 101 0000 10 Includes housing cover w bearing four screws and washer Tube Kit TU 1124 0000 00 Includes 9 of each of the following 1 16 ID in a sleeve 1 8 ID 3 16 ID and 4 ID thermoplastic elastomer tubing See chart on page 5 for tubing and roller compatibility Model 907 only Fuses 5 amp 5 pack FU 1127 00 05 Fuses 1 amp 5 pack FU 1127 01 00 Fuses 2 amp 5 pack FU 1127 02 00 Fuses 3 amp 5 pack FU 1127 03 00 Fuses 5 amp 5 pack FU 1127 05 00 No washer necessary for units using an all plastic roller bracket assembly 2 to 36 RPM Copyright 12 97 28 4000 00 00 Revised 2 13 2002 11