1. 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 O D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect 1 1 4 O D tailpiece on POP UP DRAIN to 1 2 PIPE 7 waste outlet THREAD 2 FLEXIBLE SUPPLIES 3 8 O D BULL NOSE RISERS 3 8 COMPRESSION 1H COMPRESSION CONNECTION NUT M968688 9 TEST INSTALLED FITTING m With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks mp Remove AERATOR 3 by turning counter clockwise using AERATOR KEY 3a Operate both HANDLES 1 to flush water lines thoroughly Replace AERATOR 3 turning clockwise using AERATOR KEY 3a CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in SINK If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions Release POP UP KNOB 4 down and check all drain connections and P trap for leaks mm Tighten WASTE if necessary OUTLET P TRAP 1 0 SERVICE To change direction of handle rotation proceed as follows To change direction of handle rotation proceed as follows Turn valve to OFF position Rotate HANDLE ESCUTCHEON 1 counter clockwise and pull off of ADAPTER 2 Remove
2. locks Suggest pau nut with spray lubricant to loosen any corrosion or debris that may have built up Push Drain Body up into the Sink and remove Note If Drain body rotates while loosening Mounting Nut insert a screw driver into overflow hole to prevent Drain Body from rotating while Mounting Nut is removed Recommended tools I Channel Locks Adjustable Wrench Phillips Screwdriver WHEN DRAIN IS REMOVED WHEN DRAIN IS REMOVED FROM ABOVE SINK FROM BELOW SINK METAL OR PLASTIC TWO PIECE DRAIN BODY METAL DRAIN BODY WITH PLASTIC TAILPIECE PLASTIC DRAIN BODY WITH PLASTIC TAILPIECE SCREWDRIVER X STOPPE STOPPER METAL STOPPER DRAIN PLASTIC n UNTHREAD BODY DRAIN BODY METAL j FLANGE S SINK A SINK f METAL OR PLASTIC M DRAIN BODY EM MOUNTING PIVOT l ROD NUT E PIVOT MOUNTING ROD NUT NUT and GASKET El PLASTIC TAILPIECE FINISHED WALL MOUNTING NUT and GASKET PLASTIC TAILPIECE M968688 American Standard MONTROSE Centerset Lavatory Faucet with Speed Connect Drain MODEL NUMBER ep 6044 XXX M962669 YYYOA HANDLE ASSEMBLY 918555 0070A Heplace the YYY with HANDLE SCREW appropriate finish code M95021
3. that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary dy to make sure it is fully inserted Fig J LOOP TOWARD REAR OF SINK Re install the Cam Cap making sure the guide teeth are facing outward If the Cam Cap does not snap into place then rotate the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Locked Mode Troubling Shooting Guide to complete installation Stopper will be Vandal Proof in Locked mode and not be removable Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H to make sure it is fully inserted Fig J LOOP TOWARD FRONT OF SINK Re install the Cam Cap making sure the guide teeth are facing outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re install the Cam into the Drain rotating the Cam if necess
4. 2 YYYOA 918049 0070A LIFT ROD AND KNOB CHROME O0 nana CHROME O02 SATIN NICKEL 295 M918035 0070A HANDLE ADAPTER 994053 0070A VALVE M922882 0070A AERATOR M968688 M922389 0070A AERATOR KEY M910833 0070A aal M962543 YYYOA PUTTY PLATE q STOPPER ASSEMBLY a e 065800 0070A ATTACHMENT NUT M913208 0070A SPONGE WASHER M962551 0070A miM ASSEMBLY M952410 YYYOA DRAIN ASSEMBLY M952430 0070A CABLE ASSEMBLY r M962431 0070A DRAIN MOUNTING KIT HOT LINE FOR HELP For toll free information and answers to your questions call 1 800 442 1902 Weekdays 8 00 a m to 6 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST IN MEXICO 01 800 839 1 2 00 Product names listed herein are trademarks of American Standard Inc AS America Inc 2008 M968688
5. ADAPTER SCREW 3 and ADAPTER 2 Remove SPRING CLIP 4 a Lift STOP WASHER 5 turn 90 and replace Replace SPRING CLIP 4 Replace ADAPTER 28 and ADAPTER SCREW 3 Align HANDLE and push onto ADAPTER 2 Turn HANDLE ESCUTCHEON 1 clockwise to tighten AERATOR 6 may accumulate dirt causing distorted and reduced water flow Remove AERATOR 6 and rinse clean See Step 9 for removing AERATOR 6 If spout drips operate handles several times from OFF to ON position Do not force handles turn only 90 1 1 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M968688 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position Follow CABLE ADJUSTMENT PROCEDURE If se n does not raise up fully or sink drains too slowly Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE m Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A W Look at the area on the Dr
6. Installation Instructions MONTROSE 6044 XXX Centerset Lavatory Faucet with the Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect Drain a feature found only on American Standard faucets Speed Connect Drain 1 3 of the parts installs in 1 3 of the time No tools needed Never needs adjustment Certified to comply with ANSI A112 18 1 Guaranteed to seal properly the first time every time M968688 Your new American Standard faucet is designed to work only with the Speed Connect drain Helpful tips for removing your current drain can be found in the Troubleshooting section of these instructions To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools AE i R Q ba Screwdriver Channel Locks Adjustable Wrench Tubing Cutter INSTALL FAUCET MAU sires before beginning Turn off hot and cold water supplies before beginning W Insert FAUCET 1 and CABLE CONNECTOR 2 through mounting holes of Sink or mounting surface Fig A B Assemble LOCKNUTS 3 onto SHANKS 4 from under side of Sink Hand tighten firmly Fig B HAND TIGHTEN SINK OR MOUNTING SURFACE INSTALL POP UP DRAIN Remove CLEAR PLASTIC COVER 1 Remove awa l SINK i CARDBOARD SPACER 2 from under DRAIN POP UP 3 Fig A Drop DRAIN BODY 4 through sink drain hole Make su
7. ain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C He attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F AG a REMOVE CAM CAP M968688 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode S removed or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G To install the stopper in Locked mode insert the Stopper into the Drain so
8. ary J i PA He attach Cable See CABLE ADJUSTMENT PROCEDURE in Unlocked Mode Troublingshooting Guide to complete installation Stopper will be in Unlocked mode and removable INSTALL CAM CAP M968688 TIPS FOR REMOVING YOUR OLD DRAIN Most existing drains can be removed quickly and easily with only a pair of channel lock pliers or a wrench However there may be situations where it is difficult to remove your old drain or determine how the drain is disassembled Depending upon the existing Drain in your sink it is either removed from above or below the sink The illustrations below show some typical drain installations and how they are disas sembled from the sink The following tips can help with some of the more common challenges in drain removal m Loosen nuts on P Trap using channel locks Suggest spraying nuts with spray lubricant to loosen any corrosion or debris that may have built up Remove P Trap half from Tailpiece Use bucket to catch any residual water in P trap m Unthread Pivot Rod Nut from Drain Body and remove Pull Stopper out from Drain Body For Drains that are removed from below Sink m Loosen Mounting Nut as far down as it will go Push Drain Body up into Sink and unthread Metal Flange from Drain Body Hemove Drain Body from below sink For Drains that are removed from above Sink m Unthread Tailpiece from Drain Body W Loosen and remove Mounting Nut and Gasket on Drain Body using channel
9. re WHITE FOAM GASKET 5 is under flange of DRAIN BODY 4 Fig B Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 8 must face towards the rear of the SINK Fig B INSTALL BLACK GASKET Install BLACK CONE GASKET 1 onto DRAIN BODY 2 from below Note The flat side of the BLACK CONE GASKET 1 must face down FLAT SIDE OF GASKET MUST FACE DOWN INSTALL GRAY LOCKNUT Install GRAY LOCKNUT 1 onto DRAIN BODY 2 from below SINK Fig A Note The flat side of the GRAY LOCKNUT 1 must face up Tighten firmly by hand No tools are required Check DRAIN FLANGE in SINK to ensure that l FLAT SIDE OF WHITE FOAM GASKET 3 is fully compressed GRAY LOCKNUT and not visible Fig B A MUST FACE UP FLANGE 5 POP UP KNOB W POP UP KNOB 1 must be fully down M968688 6 ATTACH CABLE CONNECTOR m Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 O D Fig B CHECK OPERATION OF POP UP Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Fig B Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 8 MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS MUST BE PURCHASED SEPARATELY Connect water su y to FAUCET 1 with

Download Pdf Manuals

image

Related Search

Related Contents

Paxton 332-110-US security or access control system  R2700 - GMC-I Messtechnik GmbH    Tabela em PDF - Diário das leis  Dell Server Management Pack Suite Version 6.1.1 für Microsoft  Instruction Manual - Galco Industrial Electronics  User Manual - American Control Electronics  Garmin Software Version 0552.05 Cockpit Reference Guide  Dimplex DF2622BLK User's Manual  E-Books lesen  