1. under side of mounting surface install VALVE BODY 3 3a through valve mounting S holes Threads of VALVE BODY 3 3a should extent at least 5 16 of a inch above mounting surface top Fig A Thread ESCUTCHEON 4 onto VALVE BODIES 3 3a 40 until snug against internal stop If necessary adjust LOCKNUT 1 Tighten LOCKNUTS 1 with WRENCH 5 supplied to secure VALVE BODIES 3 3a 4 Remove ESCUTCHEON 6 WASHER 7 and 10 UPPER GASKET 8 from TRANSFER VALVE 9 MOUNTING Insert TRANSFER VALVE 9 into the center forward SURFACE hole of BIDET Replace UPPER GASKET 8 and WASHER 7 and ESCUTCHEON 6 until it locks against internal stop Position the side threaded outlet rearward and secure MOUNTING NUT 11 2 1 SPRAY INSTALLATION Assemble SPRAY BODY 1 to BIDET Using putty seal underside of SPRAY BODY FLANGE 2 and secure with NUT 3 Thread SPRAY HOSE 4 with SEAL WASHER 5 to SPRAY BODY 1 Connect other end of HOSE 4 with SEAL WASHER 6 to side outlet NIPPLE 7 of the TRANSFER VALVE 8 Thread SPRAY CAP 9 onto SPRAY BODY 1 3 POP UP DRAIN Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B S 4 REMOVE FLANGE E Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 from drain body Fig A E Thread LOCKNUT 3 clockwis
2. 4 and LEVER HANDLE 2 Tighten HANDLE SCREW 1 1 4 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE If spout drips operate handles several times from OFF to ON position Do not force handles turn Ony 90 M968795Rev 1 1 SpeedConnect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If oe does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by t
3. Installation Instructions COLONY COLONY SOFT E t Bidet Faucet and Transfer Valve with SpeedConnect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American Standard faucets Certified to comply with ANSI A112 18 1 SpeedConnect Drain Meee ace ye e Fewer parts installs in less time e Never needs adjustment Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the SpeedConnect drain To ensure that your installation proceeds smoothly please read these instructions carefully before you begin resi Required tools Ay ughing in TRANSFER VALVE FINISHED 8 T0 12 A imensions FOR FLUSHING WALL Al BIDET OUTLINE FIM OR e IS SYMBOLIC N 7 8 a Screwdriver ES Putty or 5 DOUCHE ADJ 1 1 7a 2 fl __ Gare TO 2 1 4 s _B Ee _ N Sag j Phillips Screwdriver ae FOR GROUND JOINT Channel Locks CONNECTION OR 1 2 A i 0 0 SLIP INLETS O l era b REAR VIEW WITH WALL REMOVED Adjustable Wrench 1 1 4 0 D TAILPIECE A Tubing Cutter BIDET FAUCET INSTALLATION Byres 1e off hot and cold water supplies before beginning Place RUBBER RING 10 into ESCUTCHEON 4 Install LOCKNUT 1 and RUBBER WASHER 2 onto VALVE BODIES 3 3a From
4. e to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE From under side of BIDET Tighten LOCKNUT 1 firmly with Adjustable install DRAIN BODY 1 up Wrench or Channel Locks through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the BIDET Install FOAM GASKET 3 and FLANGE 4 onto drain body from above BIDET and tighten FLANGE 4 firmly FLANGE GASKET Check DRAIN FLANGE in BIDET to ensure that WHITE FOAM GASKET 1 is fully compressed and not visible Fig A POP UP ROD ASSEMBLY SLOTTED Insert LIFT ROD GUIDE 4 and CABLE CONNECTOR 2 S Eii through rear hole making sure SEAL WASHER 3 is properly seated Fig B Aani con a4 ASKET ILLUSTRATION NOT VISIBLE SHOWN LESS 2 From below slip slot in MOUNTING NUT 4 over CABLE 5 VALVES Thread NUT 4 onto lift rod guide shank to secure ROD GUIDE 1 to bidet Hand tighten only Fig B M968795Rev 1 1 ATTACH CABLE CONNECTOR m POP UP KNOB 1 must be fully down Fig A Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig B Your new POP UP DRAIN installation is now complete Fig C Note Tailpeice on pop up drain is 1 1 4 O D Fig C CHECK OPERATION OF POP UP Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and cl
5. he HANDLE STEM 1 Install the ADAPTER SCREW 3 and tighten securely Position LEVER HANDLE 4 and place on ADAPTER 2 INSTALL HANDLES Acrylic Turn HANDLE STEM 1 to OFF position Place the ACRYLIC HANDLE 2 on the HANDLE STEM 1 Install the HANDLE SCREW 3 and tighten securely Push in INDEX BUTTON 4 Install the HANDLE SCREW 5 and tighten securely with hex wrench supplied 1 2 TEST INSTALLED FITTING OUTLINE OF BIDET m With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks m m Operate both HANDLES 1 to flush water lines thoroughly E Rotate TRANSFER VALVE 5 from rim wash to spray several times to check operation 1 3 CHECK DRAIN CONNECTIONS Pull up POP UP KNOB 3 and fill Sink with water Check that DRAIN STOPPER 4 makes a good seal and retains water in Bidet If STOPPER 4 does not seal properly please refer to Troubleshooting Guide in these instructions Push POP UP KNOB 3 down and check all drain connections and P trap for leaks m Tighten if necessary SERVICE To change direction of handle rotation proceed as follows Turn VALVE to OFF position Loosen HANDLE SCREW 1 Pull HANDLE 2 off ADAPTER 3 Loosen ADAPTER SCREW 4 and pull off ADAPTER 3 Turn ADAPTER 3 90 in a way that flat in ADAPTER 3 catches on the other FLAT on VALVE STEM 5 Reinstall ADAPTER SCREW
6. hreading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F 7 tam GC Tl REMOVE CAM CAP M968795 Rev 1 1 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode E Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G E To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G m Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J m Re install the Gam Cap making sure the guide tee
7. ose properly then refer to the troubleshooting section of these instructions INSTALL DIVERTER KNOB Push DIVERTER KNOB 1 onto HANDLE ADAPTER 2 Push on RING 3 and tighten with SCREW 4 Press on KNOB CAP 5 Note Screwdriver gap is for disassembling and should point downwards TEE AND HOSE CONNECTION OUTLINE OF a Insert SEAL 1 into ADAPTER 2 and tighten ADAPTER 2 to side of TRANSFER VALVE 3 Install SEAL 4 into coupling nut of TEE 5 and tighten connection to ADAPTER 2 Connect HOSE COUPLING NUTS 6 to Hot and Cold valve bodies and securely tighten 9 3 8 O D BULL NOSE x cS WATER SUPPLY CONNECTION g RISERS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS NOT M COMPRESSION INCLUDED AND MUST BE PURCHASED SEPARATELY 2 Connect water supply to VALVE BODIES 7 7a with FLEXIBLE 1 2 IPS FLEXIBLE SUPPLIES 8 or 3 8 0 D BULL NOSE SUPPLIES RISERS 9 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant appropriate connectors and COUPLING NUTS NF CONNECT TO Connect 1 1 4 Q D tailpiece on POP UP DRAIN to 3 8 COMPRESSION waste outlet CONNECTION MS968795Rev 1 1 INSTALL HANDLES Lever Turn HANDLE STEM 1 to OFF position Place the HANDLE ADAPTER 2 on t
8. th are facing ed REAR OE BINET outward If the Cam Cap does not snap into place then rotate the Cam to make sure it is fully inserted Fig K m Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Locked Mode Troubling Shooting Guide to complete installation Stopper will be Vandal Proof in Locked mode and not be removable Unlocked Mode m Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H m To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H E Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J lt LOOP TOWARD E Re install the Cam Cap making sure the guide teeth are facing FRONT OF BIDET outward If the Cam Cap does not snap into place then rotate the Cam to make sure it is fully inserted Fig K m Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Unlocked Mode Troublingshooting Guide to complete installation Stopper will be in Unlocked mode and removable INSTALL CAM CAP M968795 Rev 1 1