1. IMPORTANT INSTRUCTIONS OPERATING MANUAL FOR OSCILLATING MODELS 3 OSCILLATION Push down oscillation knob on motor housing to make fan head move from side to side NOTE FOR OSCILLATING MODELS FAN IS SHIPPED WITH 90 OSCILLATION ANGLE FOR 45 OSCILLATION ANGLE CONNECT THE OSCILLATION LINK TO THE INNER MOST HOLE IN THE CAM GEAR Inset A Inset A MAINTENANCE WARNING ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING WARNING DO NOT IMMERSE FAN IN WATER CLEANING Use a soft cloth and mild soap solution such as liquid dish washing detergent Dry all parts completely before reconnecting to power supply CAUTION Do not use gasoline benzine thinner harsh cleaners etc as they will damage the Fan NEVER use ALCOHOL OR SOLVENTS SERVICING All other servicing with the exception of general user maintenance should be performed by an authorized service representative Call 1 800 233 0268 Monday through Friday between the hours of 8 00 a m and 5 00 p m EST for the location of your nearest service center LUBRICATION Precision bearings are sealed at the factory for life and do not require further lubrication STORAGE Store the Fan with these instructions in a clean and dry place LIMITED WARRANTY WHAT THIS WARRANTY COVERS This product is warranted against defects in workmanship and or materials HOW LONG THIS WARRANTY LASTS This warranty extends only to the original purchaser of the product and lasts f
2. 30 NON OSCILLATING WALL MOUNT FAN MODEL 9024 9030 9070 9071 GENERAL SAFETY INFORMATION When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to person including the following s Read all instructions before using Fan 2 Make certain that the power source conforms to the electrical requirements of the Fan 3 Use this Fan only as described in this manual Any other use not recommended by the manufacturer may cause fire electrical shock or injury to persons 4 To reduce the risk of personal injury and electric shock the Fan should not be played with or placed where small children can reach it 5 Unplug power cord before servicing or moving the Fan ARNING DO NOT DEPEND UPON THE ON OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN ALWAYS UNPLUG THE POWER CORD 6 This Fan must NOT be used in potentially dangerous lo cations such as flammable explosive chemical laden or wet atmospheres 7 DO NOT use Fan in or near a window Rain may create an electrical hazard 8 Completely reassemble Fan according to instructions before reconnecting to power supply 9 The power cord is equipped with a three prong grounded plug that must be inserted into a matching receptacle Under no circumstances should the grounding prong be cut off the plug Where a two prong wall receptacle is encountered it must be
3. Never locate a Fan where it may fall into a bathtub or other water container 15 Do not use Fan outdoors 16 This Fan is not suitable for use in hazardous locations Please refer to National Electric Code NEC Article 500 or applicable state or local codes or standards relating to electrical requirements for Hazardous locations THIS FAN DOES NOT MEET THE REQUIRMENTS OF NEC ARTICLE 500 2002 WARNING REDUCETHE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES CAUTION BECAUSE OF THE SIZE AND WEIGHT OF THIS FAN MAKE SURE ALL PARTS ARE COMPLETELY ASSEMBLED ACCORDING TO INSTRUCTIONS FAILURE TO DO SO COULD RESULT IN FAN COMING APART DURING OPERATION AND OR PERSONAL INJURY 5084414 IMPORTANT INSTRUCTIONS OPERATING MANUAL WALL BRACKET INSTALLATION Figures 1 through 4 IMPORTANT INSTRUCTIONS OPERATING MANUAL require the use of a flathead screwdriver to complete assembly Stand behind the Fan Slip the flat of the screwdriver between the Front NOTE Always install the bracket to a minimum of 2 x 4 studding and Rear Grills next to one of the unfastened hooks Figure 6 Detail B Pull screwdriver handle upwards towards the Rear Grill Slip the 1 Insert the 7 16 14 x 3 1 2 Bolt through Flag Bracket Wall Bracket and into the 7 16 14 Lock Nut Tighten with Adjustable Wrenches MAKE Front Grill hook over the Rear Grill outer ring with a push Re
4. 2 5084414 Rev A 9 07 3 5084414
5. BILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these exclusions or limitations may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state and province to province Proof of purchase is required before a warranty claim will be accepted CUSTOMER SERVICE Toll Free 800 233 0268 Email producthelp laskoproducts com Our Customer Service team is available to assist you with product questions service center locations and replacement parts They can be reached Monday through Friday 8am 5pm Eastern Please have your model number available as well as the type and style located on the underside of your product Please do not return product to place of purchase Customer Service Dept 820 Lincoln Ave West Chester PA 19380 Please do not send product to this location www laskoproducts com PARTS FOR DISCONTINUED OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE DUETO SAFETY REASONS MANY ELECTRONIC COMPONENTS AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT Rev A 9 07 4 5084414 IMPORTANT INSTRUCTIONS OPERATING MANUAL Ventilation Products 24 30 OSCILLATING WALL MOUNT FAN MODEL 9025 9035 9074 9075 24
6. DARY SUPPORT CABLE Figure Large Guard PROVIDED SHOULD BE USED ANYTIME THE Wires CIRCULATOR IS MOUNTED OVERHEAD FOR ADDITIONAL SAFETY SECONDARY SUPPORT CABLE Figures 7 and 8 NY Wall Bracket Wall Mount Assembly Non Oscillating Motor Shown 1 Loop one end of Cable around the Large Guard Wires of both the Front and Rear Grills 2 Attach a Cable Clamp with the U on the tail side of the loop leaving a tail approximately 1 to 2 inches Tighten Clamp Nuts Make sure no part of the Cable Fi interferes with the Blade D Final Assembly of Motor to 3 Wrap the other end of the Cable around a secure building joist truss or other sup i Wall Mount Bracket port near the Fan Take up all excess slack in the Cable CAUTION USE ONLY THE MOUNTING HARDWARE WHICH IS RECOMMENDED FOR USE ON THIS FAN 4 Attach the remaining Cable Clamp as indicated in Step 2 The excess tail should be trimmed to extend 1 to 2 inches past the Clamp 5 Check the Assembly to assure the Blade is free of all obstructions CAUTION Use of the secondary support cable does not guarantee Detailed View of Hardware Oscillating Motor Shown protection againstinjury of persons mounting of both the circulator and cable could fail if subjected to abuse neglect or improper installation Figure 3 Figure 4 M FN GRILL AND BLADE ASSEMBLY Figures 5 and 6 NOTE The assembly of the blade and grill is identic
7. al regardless if the Fan has an oscillating motor or a non oscil OPERATING INSTRUCTIONS lating motor 1 TO OPERATE Plug cord into a grounded 120V 60 Hz outlet Select desired operating speed with pull cord on the rear of the motor 1 Install the Rear Grill onto the Motor lining up the six holes in the grill with the six threaded holes in the Motor Install 6 10 32 X 5 16 First pull High Second Pe ill i i ji Third pull Low Fourth pull OFF epee a a a i OFK NOTE THIS FAN IS VERY HEAVY g the Hub facing away from the motor until it stops against the shaft Inset A Align Square Head Bolt with flat of the Motor Shaft TIGHTEN VERY SECURELY WITH AN ADJUSTABLE WRENCH Failure to securely tighten Failure to securely hold onto head assembly while adjusting head angle the Bolt could result in damage to the Fan and or personal injury could result in personal injury 3 Hold the Front Grill so that the name in the center is right side up and straight across Starting at the top Fasten Front Grillto Rear Grill 2 TO ADJUST HEAD ANGLE While holding head firmly loosen knob under motor turn counterclockwise Tilt head to desired position by sliding the hooked wires on the Front Grill over the outermost ring on the Rear Grill Figure 6 Detail A The bottom most hooks will FIRMLY retighten knob under motor NOTE Motor Head Adjustment Knob and the On Off Pull Cord have the same location on oscillating or non oscillating models Rev A 9 07
8. or one 1 year from the date of original purchase or until the original purchaser of the product sells or transfers the product whichever first occurs WHAT AIR KING WILL DO During the warranty period Air King will at its sole option repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model WHAT THIS WARRANTY DOES NOT COVER This warranty does not apply if the product was damaged or failed because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR Il REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIA
9. peat procedure with remaining hooks CERTAIN THE DIRECTION OF THE FLAG BRACKET is as shown in Figure 1 CAUTION DO NOT BEND WIRES ON THE FRONT OR THE REAR GRILLS 2 THE HARDWARE TO ATTACH THE WALL BRACKET TO THE WALL STUD IS NOT SUPPLIED Locate the wall stud nearest to the desired Figure 5 Figure 6 Fan location Attach the Wall Bracket to the stud using 3 5 16 diameter x 2 long Lag Screws g g DAA 3 Position the Flag Bracket in the Motor Neck and align the Pivot Hole with the Larger Hole in the Flag Bracket Figure 2 Top Hooks 4 Attach pull string to motor speed switch if desired 5 Insert the 1 2 X 1 Hex Bolt 3 4 head through the Motor Neck and the Flag Bracket Place 1 2 diameter Split Lockwasher then the 1 2 diameter Hex Nut 3 4 head and tighten fully with 2 adjustable wrenches Figure 3 x 6 From the same side of the Motor Neck insert one 1 4 20 X 1 5 8 Carriage Bolt through the Arc Shaped Slot in the Motor Neck and Hole in 3 the Flag Bracket Figure 3 z To Fasten Place one 1 4 Flatwasher one 1 4 Internal Tooth Lockwasher a second 1 4 Flatwasher and then tighten the Adjustable Knob over the remaining threads Final assembly of the Motor to the Wall Mount Bracket is illustrated in Figure 4 Figure 1 Figure 2 Detail B Bottom Hooks J 6 14 X 3 1 2 Bolt Non Oscillating Motor Shown Non Oscillating Motor Shown Flag Bracket Placement of Motor to Flag Bracket 7 16 14 Lock Nut Motor Neck CAUTION THE SECON
10. replaced with a properly grounded three prong receptacle installed in accordance with the National Electrical Code NEC and all applicable local codes and ordinances This work must be done only by a qualified electrician using copper wire only WARNING USE OF A THREE PRONG TO TWO PRONG ADAPTER IS NOT RECOMMENDED IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTROCUTION USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA Rev A 9 07 SAVE THESE INSTRUCTIONS 10 Where possible avoid the use of extension cords If they must be used minimize the risk of overheating by ensuring that they are UL listed Never use a single extension cord to operate more than one Fan 11 Do not operate any Fan with a damaged cord or plug or after the Fan malfunctions has been dropped or damaged in any manner Return Fan to authorized service facility for examination electrical or mechanical adjustment or repair 12 Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire or damage the Fan Do not block or tamper with the Fan in any manner while it is in operation 13 Locate the Power Cord so the Fan or other objects are not resting onit Do not run Power Cord under carpeting Do not cover Power Cord with throw rugs runners or the like Arrange Power Cord away from room traffic and where it will not be tripped over 14 This Fan is not intended for use in wet or damp locations