Home
Air King 4C630P/9012P Fan User Manual
Contents
1. IF THE FAN DOES NOT FUNCTION PROPERLY IT MAY BE DUE TO THE SAFETY DEVICE INCORPORATED IN THIS PLUG 8 Where possible avoid the use of extension cords If they must be used minimize the risk of overheating by ensuring that they are UL listed Never use a single extension cord to operate more than one Fan 9 NEVER operate any Fan with a damaged cord or plug or after the Fan malfunctions has been dropped or damaged in any manner 10 Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire or damage the Fan Do not block or tamper with the Fan in any manner while it is in operation 11 Always place the Fan on a stable flat level surface when operating to avoid the chance of the Fan overturning Locate the Power Cord so the Fan or other objects are not resting on it Do not run Power Cord under carpeting Do not cover Power Cord with throw rugs runners or the like Arrange Power Cord away from room traffic and where it will not be tripped over 12 This Fan is not intended for use in wet or damp locations Never locate a Fan where it may fall into a bathtub or other water container 13 Do not use Fan outdoors 14 This Fan is not suitable for use in agricultural facilities including areas where livestock poultry or other animals are confined Please refer to National Electric Code NEC Article 547 7 2008 or applicable state or local codes or standar
2. ESPIGAS LA CONEXION INDEBIDA PODRIA CREAR EL RIESGO DE SER ELECTROCUTADO ELUSO DE TALES ADAPTADORES NO EST PERMITIDO EN CANAD ADVERTENCIA ESTE ENCHUFE ES UNA MEDIDA DE SEGURIDAD PARA REDUCIR EL RIESGO DE INCENDIO CHOQUE EL CTRICO Y LESIONES PERSONALES NO QUITE NI REEMPLACE NI REPARE O ALTERE EL ENCH FE QUE SE PROVEE ORIGINALMENTE SI EL VENTILADOR NO FUNCIONA CORRECTAMENTE PUEDE DEBERSE AL DISPOSITIVO DE SEGURIDAD INCORPORADO EN ESTE ENCHUFE 8 De ser posible evite el uso de cables de extensi n Si debieran usarse minimice el riesgo de sobrecalentamiento procurando que est n aprobados por UL Nunca use un solo cable de extensi n para hacer funcionar m s de un Ventilador 9 No haga funcionar ning n Ventilador con un cable o enchufe da ado o despu s de que el ventilador presente alg n desperfecto o haya sido dejado caer o sufriera cualquier tipo de da o 10 No introduzca ni permita que se introduzcan dedos u objetos extra os en ninguna abertura de ventilaci n o escape puesto que podr a provocar un golpe de electricidad incendio o da os al ventilador No bloquee ni manipule el Ventilador de ninguna manera mientras est en funcionamiento 11 Siempre coloque el Ventilador sobre una superficie estable plana y horizontal mientras est en funcionamiento para evitar la posibilidad de que el Ventilador se d vuelta Ubique el cable el ctrico de tal modo que el ventilador u otros objetos no descansen sobre l No
3. disponga el cable el ctrico debajo de alfombras No cubra el cable el ctrico con tapetes alfombras continuas u objetos similares Coloque el cable el ctrico fuera del paso de las personas y donde nadie se tropiece con el mismo 12 Este Ventilador no ha sido dise ado para usarse en lugares mojados o h medos Nunca coloque un Ventilador donde quepa la posibilidad de que caiga en una ba era u otro recipiente con agua 13 No use el Ventilador en exteriores 14 Este Ventilador no es adecuado para usar en instalaciones de agricultura incluyendo reas donde se almacene ganado aves de corral u otros animales Por favor consulte el Articulo 547 7 2008 del C digo El ctrico Nacional NEC o los c digos o normas estatales o locales aplicables con relaci n a los requisitos el ctricos para edificios destinados a las agricultura ESTE VENTILADOR NO CUMPLE CON LOS REQUISITOS DEL ARTICULO 547 7 DEL NEC 2008 15 Este Ventilador no es adecuado para usar en lugares peligrosos Por favor consulte el Art culo 500 del C digo El ctrico Nacional NEC o los c digos o normas estatales o locales aplicables con relaci n a los requisitos el ctricos para lugares peligrosos ESTE VENTILADOR NO CUMPLE CON LOS REQUISITOS DEL ARTICULO 500 2008 ADVERTENCIA DISMINUYA EL RIESGO DE INCENDIO O GOLPES DE ELECTRICIDAD NO USE ESTE VENTILADOR CON ARTEFACTOS DE CONTROL DE VELOCIDAD EN ESTADO SOLIDO CONSERVE ESTAS INTRUCCIONES 2084077 MODELO 4C6
4. 3 Use this Fan only as described in this manual Any other use not recommended by the manufacturer may cause fire electrical shock or injury to persons 4 Unplug power cord before installing servicing or moving the Fan WARNING DO NOT DEPEND UPON THE ON OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN ALWAYS UNPLUG THE POWER CORD 5 This Fan must NOT be used in potentially dangerous locations such as flammable explosive chemical laden or wet atmospheres 6 DO NOT use Fan in or near a window Rain may create an electrical hazard 7 The power cord is equipped with a three prong grounded plug that must be inserted into a matching receptacle Under no circumstances should the grounding prong be cut off the plug Where a two prong wall receptacle is encountered it must be replaced with a properly grounded three prong re ceptacle installed in accordance with the National Electrical Code NEC and all applicable local codes and ordinances Rev G 9 09 This work must be done only by a qualified electrician using copper wire only WARNING USE OF A THREE PRONG TO TWO PRONG ADAPTER IS NOT RECOMMENDED IMPROPER CONNECTION MAY CRE ATE THE RISK OF ELECTRIC SHOCK USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA WARNING THIS PLUG IS A SAFETY FEATURE TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK AND PERSONAL INJURY DO NOT REMOVE REPLACE REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG
5. 3 4 PPH Type 25 4 02090272 02090272 Rubber Foot 5 2060202 2060202 Rear Hanging Plate 6 2010554 2010554 Switch Wire Cover 7 2090008 2090008 Screw 8 x 1 2 8 02055047 02055047 Switch with Pull Cord 9 7091854 7091854 Crimp Connect 2010512P 2010512P Body 2090539 2090539 Pull Cord Bushing 02090744 02090744 Pendant 02035035 02035036 Motor Assembly 02010162B 02010162B Ratchet Plate 02090518 02090521A 02090518 02090521A Elevation Spring Elevation Shaft 02090033 02090033 Hex Nut 02010548A 02010548A H C Buttons 2010131 2010131 Switch Knob 02050009FPB 02050009FPB Cord Set 2011212 2011200M Rear Grill 2010359 2010359 Guard Nut 2010008 2011013 Blade 2010058 2010090 Spinner 02096217 020962141 Front Grill 02010381A 02010381A Ornament alulalaladlallalaln aloja ala lalalala m al mo mi o ns 2084077 MANUAL DE INSTRUCCIONES DE OPERACI N Y PARTES Ventilation Products VENTILADORES OSCILANTES DE MONTAJE EN PARED 12 30 4 cm MODELO 4C630P 901 2P e 16 40 6 cm MODELO 4C631Q 9016Q LEA Y GUARDE ESTAS INSTRUCCIONES L ALAS CUIDADOSAMENTE ANTES DE INTENTAR ARMAR INSTALAR OPERAR O DAR MANTENIMIENTO AL PRODUCTO DESCRITO PROT JASE A S MISMO Y A LOS DEM S OBSERVANDO TODA LA INFORMACI N SOBRE SEGURIDAD NO SEGUIR LAS INSTRUCCIONES P
6. 30P 9012P y 4C631Q 9016Q Parrilla Tuerca Posterior Plastica JR Detalle 1 ARMADO Figura 1 1 Coloque la Parrilla Posterior en el Motor alineando la leng eta de la Parrilla Posterior con la ranura que se encuentra en el Motor Detalle1 Asiente totalmente la Parrilla Posterior en el Motor y fijela con la Tuerca Pl stica haci ndola girar en el Sentido de las Manecillas del Reloj Deslice el Aspa hasta montarla en el Eje del Motor Alinee la ranura que se encuentra en el cubo del aspa con la clavija del eje del motor Detalle 2 4 Para fijar el Aspa atornille el Rotador en el Eje en el sentido Contrario de las Manecillas del Reloj hasta que se encuentre fijo en el cubo del Aspa E 5 Encaje la Parrilla Anterior en su lugar N wo INSTALACION 1 Coloque un perno prisionero detras de la pared Si no puede encontrar un perno prisionero usted podra encontrar tipos especiales de pernos de anclaje en su ferreteria local Fije la Placa de Montaje a la pared con los Tornillos que vienen incluidos Tornillos para Madera 8 X 1 1 4 Procure que la brida apunte hacia arriba como se muestra en la ampliaci n que se encuentra m s arriba vea la ampliaci n 1 3 El Ventilador ahora est listo para ser colgado en la Placa de Montaje N FUNCIONAMIENTO OSCILACI N VARIABLE Jale la perilla de oscilaci n ubicada en la parte posterior del motor hacia arriba Gire el cabezal del Rev G
7. 4C630P 9012P y 4C631Q 9016Q GARANT A LIMITADA QU CUBRE ESTA GARANT AS Este producto est garantizado contra defectos de mano de obra y o materiales CU NTO DURA ESTA GARANT A Esta garant a se extiende nicamente al comprador original del producto y dura un 1 a o a partir de la fecha original de compra o hasta que el comprador original del producto venda o transfiera el producto cualesquiera de ambas que ocurriera en primer lugar QU HAR AIR KING Durante el per odo de garant a Air King a opci n propia reparar o reemplazar cualquier parte o partes que demuestren ser defectuosas o reemplazar el producto completo por el mismo modelo u otro comparable QU NO CUBRE ESTA GARANT A Esta garant a no tiene validez si el producto fue da ado o fall debido a un accidente manipulaci n u operaci n inadecuadas da o en el env o abuso mal uso reparaciones no autorizadas hechas o el intento de hacerlas Esta garant a no cubre los costos de env o para la devoluci n de productos a Air King para su reparaci n o reemplazo Air King abonar los cargos de env o de devoluci n a Air King con posterioridad a las reparaciones o el reemplazo bajo garant a CUALESQUIERA Y TODAS LAS GARANT AS EXPL CITAS O IMPL CITAS INCLUYENDO SIN LIMITACI N CUALESQUIERA GARANT A IMPL CITA DE COMERCIABILIDAD DURAN UN A O A PARTIR DE LA FECHA ORIGINAL DE COMPRA O HASTA QUE EL COMPRADOR ORIGINAL DEL PRODUCTO VENDA O TRANSFIERA EL PRODUC
8. 9 09 Im 2 7 nN l Y J a EA ll l Aspa Rotador ELA Ornamento Parrilla Anterior ventilador hacia la izquierda derecha o hacia delante Empuje la perilla de oscilaci n hacia abajo y el ventilador oscilar describiendo el ngulo fijado NGULO VERTICAL Para ajustar el ngulo vertical incline el cabezal del ventilador hacia arriba o abajo seg n prefiera VELOCIDAD La velocidad se controla mediante un interruptor activado con una cadenilla de tiro La velocidad fijada se indica mediante la perilla del interruptor ubicada en la cubierta anterior Apagado Baja Mediana Alta Apagado CABLE DE ALIMENTACI N EL CTRICA Enchufe el cable el ctrico en un tomacorriente de pared 120 Voltios CA 60 Hz MANTENIMIENTO ADVERTENCIA SIEMPRE DESENCHUFE EL CABLE ANTES DE MOVER O DAR SERVICIO AL VENTILADOR ADVERTENCIA NO SUMERJA EL VENTILADOR EN AGUA LIMPIEZA Utilice un pa o suave humedecido con una soluci n jabonosa liviana tal como un detergente l quido para lavar platos Seque TODAS LAS PARTES POR COMPLETO antes de rearmar Despu s de dar mantenimiento o servicio REARME POR COMPLETO la unidad en la forma descrita en este manual de instrucciones antes de volver a conectarla a la fuente de poder PRECAUCI N No utilice gasolina bencina acetona limpiadores abrasivos etc puesto que da ar n el Ventilador NUNCA use ALCOHOL O SOLVENTES LUBRICACI
9. MODELO 4C630P 9012P y 4C631Q 9016Q LISTA DE REPUESTOS 1 20 2090003 2090003 Placa de Montaje Tornillo Phillips 8 x 1 1 4 Ref Parte No for Modelo NO OT 101 7 101 PA 5d 4C631Q 9016Q Descripci n Cant 60316 2060316 1 02090045A 02090045A Tornillo Phillips Tipo 25 8 x 3 4 02090272 02090272 Pata de Caucho 2060202 2060202 Placa Tracera para Colgar 2010554 2010554 Tapa del Interruptor 2090008 2090008 Tornillo Phillips 8 x 1 2 02055047 02055047 Interruptor con Cord n Accionador 7091854 7091854 Plastico Protector 2010512P 2010512P Cuerpo 2090539 2090539 Casquillo del Cord n Accionador 02090744 02090744 Tire Cuerda 02035035 02035036 Conjunto de Motor 02010162B 0 5 02010162B 0 5 Placa de Trinquete 02090521A 02090521A Eje de Elevaci n 02090033 02010548A 02090033 02010548A Tuerca Hexagonal Boton Tipo H C 2010131 02050009FPB 2011212 1035 2010131 02050009FPB 2011200M 1035 Bot n del Interruptor Rotatorio Cord n El ctrico Rejilla Pl stica Trasera uerca de Segurida 2010008 2011013 Aspa 2010058 2010090 Tapa 02096217 020962141 Rejilla Frontal Rev G 9 09 02010381A 02010381A Ornamento 2084077 mh d ak al dl dl St fp a et Sy Sy py Ventilation Products OPERATING IN
10. N Los cojinetes de precisi n vienen sellados de por vida en la f brica y no precisar n ninguna lubricaci n adicional ALMACENAMIENTO Guarde el Ventilador con estas instrucciones en un lugar fresco y seco 2084077 MODEL 4C630P 9012P and 4C631Q 9016Q LIMITED WARRANTY WHAT THIS WARRANTY COVERS This product is warranted against defects in workmanship and or materials HOW LONG THIS WARRANTY LASTS This warranty extends only to the original purchaser of the product and lasts for one 1 year from the date of original purchase or until the original purchaser of the product sells or transfers the product whichever first occurs WHAT AIR KING WILL DO During the warranty period Air King will at its sole option repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model WHAT THIS WARRANTY DOES NOT COVER This warranty does not apply if the product was damaged or failed because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGI
11. NAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these exclusions or limitations may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state and province to province Proof of purchase is required before a warranty claim will be accepted Rev G 9 09 3 2084077
12. ODR A RESULTAR EN LESIONES PERSONALES Y O DA OS A LA PROPIEDAD UARDE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS DESCRIPCI N Los Ventiladores Oscilantes Air King de 12 30 4 cm y 16 40 6 cm para Montaje en Pared cuentan con un control de velocidad accionado por un perilla rotativa cord n oscilaci n variable un motor de condensador de divisi n permanente y la parrilla ante rior de la malla del acero que satisfacen las normas OSHA con un cord n el ctrico de 6 pies 1 8m 18 3 ESPECIFICACIONES MoOtOfTisoiicioci sri caninas 120V 60Hz 12 30 4 cm 120V 60Hz 16 40 6 cm Tama o de paletas 12 30 4 cm Modelo 4C630P 901 2P 16 40 6 cm Modelo 4C631Q 9016Q Velocidades ceeeeeee 3 GOntrOl seisiesseccevsisecisee cseuscwene Perilla Rotativa Cord n Distribuci n del lujo de aire 90 AProbaCiONnes seseceeeeeeeeeens Catalogaci n ETL El protector de malla cerrada del Ventilador satisface las normas OSHA Cama ema ama 2P 4C631 Aa ina aaa MEDIA MEDIA BAJA ALTA MEDIA ALTA MEDIA BAJA INFORMACI N GENERAL DE SEGURIDAD Al usar aparatos el ctricos las precauciones b sicas de seguridad deberan siempre de seguirse para reducir el riesgo de incendio choque el ctrico y da o a personas incluyenda las siguientes Lea todas las instrucciones antes de utilizar el Ventilador 2 Cerci rese de que la fuente de poder sea compatible
13. STRUCTIONS amp PARTS MANUAL WALL MOUNTED OSCILLATING FANS 12 30 4 cm MODEL 4C630P 9012P 16 40 6 cm MODEL 4C631Q 9016Q READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DE SCRIBED PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE DESCRIPTION Air King 12 30 4 cm and 16 40 6 cm Wall Mounted Oscillating Fans offer rotary knob pull cord speed control variable oscillation a permanent split capacitor motor and OSHA complying front steel mesh grill with a 6 ft 1 8m 18 3 cord set SPECIFICATIONS Moto viii 120V 60 Hz 12 30 4 cm 120V 60 Hz 16 40 6 cm Blade diameter oo 12 30 4 cm Model 4C630P 901 2P 16 40 6 cm Model 4C631Q 9016Q Speeds A 3 GONTIO erci ccnaninc nionaraiiamenias Rotary Knob Pull Cord Air flow distribution go AD ProvalS iececcccectssctecdevcnnes ETL Listed Close mesh Fan Guard GENERAL SAFETY INFORMATION When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to person including the following 1 Read all instructions before using Fan 2 Make certain that the power source conforms to the electrical requirements of the Fan
14. TO CUALESQUIERA DE AMBAS QUE OCURRIERA EN PRIMER LUGAR Y EN NING N CASO LA RESPONSABILIDAD DE AIR KING BAJO CUALQUIER GARANT A EXPL CITA O IMPL CITA INCLUIR 1 DA OS INCIDENTALES O POR CONSECUENCIA POR CUALQUIER CAUSA QUE FUERE O II REEMPLAZO O REPARACI N DE CUALESQUIERA FUSIBLES HOGARE OS CORTA CIRCUITOS O TOMACORRIENTES INDEPENDIENTEMENTE DE CUALQUIER DECLARACI N CONTRARIA EN NING N CASO LA RESPONSABILIDAD DE AIR KING BAJO CUALQUIER GARANT A EXPL CITA O IMPL CITA PODR EXCEDER EL PRECIO DE COMPRA DEL PRODUCTO Y DICHA RESPONSABILIDAD TERMINAR AL VENCIMIENTO DEL PER ODO DE GARANT A Algunos estados y provincias no permiten limitaciones sobre la duraci n de una garant a impl cita o sobre la exclusi n o limitaci n de los da os incidentales o por consecuencia por lo tanto dichas exclusiones o limitaciones podr an no aplicarse en su caso Esta garant a le otorga a usted derechos legales espec ficos Usted tambi n podr a tener otros derechos que var an de estado en estado y de provincia en provincia Se requiere prueba de compra antes que se acepte un reclamo bajo garant a Rev G 9 09 7 2084077 MODEL 4C630P 9012P and 4C631Q 9016Q Rev G 9 09 Pee pe ine HS REPLACEMENT PARTS LIST Part No for Model Key 4C630P 9012P 4C631Q 9016Q Description 1 2060316 2060316 Mounting Plate 2 2090003 2090003 Screw 8 x 1 1 4 Wood Screw 3 02090045A 02090045A Screw 8 x
15. con las demandas el ctricas del Ventilador 3 Use este Ventilador s lo en la forma que se describe en el manual Cualquier otro uso no recomendado por el fabricante podr a ocasionar un incendio golpes de electricidad o lesiones a personas 4 Desenchufe el cable el ctrico antes de instalar proporcionar servicio o mover el Ventilador ADVERTENCIA NO DEPENDA DEL INTERRUPTOR DE ENCENDIDO APAGADO COMO EL UNICO MEDIO PARA DESCONECTAR LA POTENCIA ALINSTALAR O PROPORCIONARLE SERVICIO AL VENTILADOR DESENCHUFE SIEMPRE EL CABLE EL CTRICO 5 Este Ventilador NO debe usarse en ubicaciones potencialmente peligrosas tales como en ambientes inflamables explosivos cargados de sustancias qu micas o h medos 6 NO use el Ventilador en o cerca de una ventana La lluvia puede generar riesgos el ctricos 7 El cord n el ctrico est equipado con una clavija a tierra de tres espigas que tiene que ser enchufada a un recept culo del mismo dise o Bajo ninguna circunstancia deber cortarse la espiga a tierra de la clavija De existir un recept culo de pared de dos espigas deber reemplazarse por uno de tres espigas debidamente puesto a tierra e instalado de conformidad con el C digo Nacional de Electricidad y todos los c digos y ordenanzas locales aplicables El trabajo deber hacerlo un electricista calificado utilizando exclusivamente alambre de cobre Rev G 9 09 ADVERTENCIA NO SE RECOMIENDA EL USO DE UN ADAPTADOR DE TRES A DOS
16. ds relating to electrical requirements for Agricultural Buildings THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547 7 2008 15 This Fan is not suitable for use in hazardous locations Please refer to National Electric Code NEC Article 500 or applicable state or local codes or standards relating to electrical requirements for Hazardous locations THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500 2008 WARNING REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES SAVE THESE INSTRUCTIONS 2084077 MODEL 4C630P 9012P and 4C631Q 9016Q QA ALO SSA f Wf ES TTS LAWS i LL it J ji Ng SA Grill Plastic Nut ASSEMBLY Figure 1 1 Put Rear Grill on Motor by aligning the tab on the Rear Grill with the groove on the Motor Detail 1 2 Fully seat Rear Grill on Motor and secure with Plastic Nut turning Clockwise 3 Slide Blade onto Motor Shaft Align groove on blade hub with pin on motor shaft Detail 2 a 4 To secure Blade screw Spinner onto Shaft Counter Clockwise until tight on Blade hub E 5 Snap Front Grill into place INSTALLATION 1 Locate a stud behind wall If stud cannot be found special types of mounting anchors are available at your hardware store 2 Secure Mounting Plate to wall with Screws supplied 8 X 1 1 4 Wood Screws Make sure flange is pointing up as shown in exploded v
17. iew above 3 Fan is now ready to hang on Mounting Plate OPERATION VARIABLE OSCILLATION Pull oscillation knob on the rear of the motor up Turn fan head to left right or straight ahead Push oscil lation knob down and fan will oscillate about the set angle VERTICLE ANGLE To adjust vertical angle tilt fan head up or down as desired Rev G 9 09 D J a aL Y B V lil i W y W NA Blade Ji Ornament SPEED Speedis controlled by a pull cord switch The speed setting is shown by switch knob on front cover Off Low Med High Off POWER SUPPLY CORD Plug power supply cord into a wall outlet AC 120Volts 60 Hz MAINTENANCE WARNING ALWAYS UNPLUG THE CORD BEFORE MOV ING OR SERVICING THE FAN WARNING DO NOT IMMERSE FAN IN WATER CLEANING Use a soft cloth moistened with a mild soap solu tion such as liquid dish washing detergent Dry ALL PARTS COM PLETELY before reassembling After any maintenance or servicing COMPLETELY REASSEMBLE unit as described in this instruction manual before reconnecting to the power supply CAUTION Do not use gasoline benzine thinner harsh cleaners etc as they will damage the Fan NEVER use ALCOHOL OR SOLVENTS LUBRICATION Precision bearings are sealed at the factory for life and will not require any further lubrication STORAGE Store the Fan with these instructions in a cool dry place 2084077 MODELO