1. Metal grease filter The purpose of the grease filters is to aspirate grease particles which form during cooking and it must always be used either in the external evacuation or internal recycling function Attention the metal grease filters must be removed and washed either by hand or in the dishwasher every four weeks Open the metal grease filter Push it towards the back of the unit and then pull it down and out Fig 4 Fig 4 Hand washing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Refit the grease filters when it are dry Dishwasher machine Place grease filters in dish washer Select most powerful washing programme and highest temperature at least 65 C Repeat the process Refit the grease filters when it are dry When washing the metal grease filter in the dishwasher a slight discoloration of the filter can occur this does not have any impact on its performance Clean the inner housing using a hot detergent solution only never use caustic detergents abrasive powders or brushes 30 Carbon filter The activated carbon filter should only be used if you want to use the hood in its filtering function To do this you will need an original AEG activated carbon filter see special accessories This filter cannot be cleaned or reused As a general rule the activated carb
2. SUPPLY are for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance IMPORTANT The wires of the mains lead supplied with this appliance are coloured in accordance with the following code Blue Neutral Brown Live As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying the ter minals in the plug proceed as follows The wire which is col oured brown must be connected to the terminal which is marked with the letter L or coloured red The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black BLUE BROWN NEUTRAL LIVE 1 DP 13A 250V N SUPPLY Technic Details Dimensions 825 D Height x Width x Depht in cm 84 117 x59 9x51 5 Dimensions 8259 D Height x Width x Depht in cm 84 117 x 89 9x 51 5 Weight 825 D Net 10 7 kg Gross 16 2kg Weight 8259 D Net 13 1kg Gross 19 6kg Maximum absorbed power 250W Motor absorption 1x170W Lighting 2x40W Length of the cable 100cm Fan powers speed speed in compliance with DIN 44971 Extractor version i 179 m h 2 219 mh 3 336 mh i 402 m h Filter version i 102 mh 2 150 m h 3 252 m h i 265 mh Flange 120 mm 23 Installation Saf
3. hooks 3 on the drilled holes Hang the hood on the hooks and adjust the position of the hood using the two screws on the bottom of the hooks 5 Remove the metal filters 4 and mark two points 6 Remove the hood and drill two 8mm holes on the marked points Fit two 8mm wall dowels 7 Hang again the hood and fix the hood definitively with two screws 5X45 8 Fix the chimney support 10 with two screws 5 x 45 mm 9 and two wall dowels 11 on the wall close to the ceiling For exhausting version Fit the connection ring S on the top of the hood with two screws 3 5 x 6 5 mm 12S then fit an axhausting pipe long enough to reach the outside 135 For recycling version Fix definitively the deflector 13K on the top of the hood with two screws 3 5 x 6 5 mm 12K Prepare the electric connection 14 see relative chapter Fit the chimney 15 and fix it on the chimney support with two screws 3 0 x 9 mm 16 The lower part of the chimney must be slided down and inserted on the housing on the upper part of the hood 17 Fit the two grids 18 on both sides of the chimney Hood Operation The hood is fitted with a variable speed motor The most effective use of the hood is obtained by switching it on a few minutes before you start cooking and leaving it on a for approximately 15 minutes after you have finished thus ensuring all cooking odours are eliminated The control switches are
4. outside Fig 1 120mm yo Fig 1 If the cooking vapour is passed through an outside wall you will need an MKZ telescopic wall pipe with intake and ventilation E Nr 610 899 004 120 mm from our range of special accessories 19 Filter version The air is filtered through an activated carbon filter and passed back into the kitchen through the top outlet duct grids You will need an original AEG KF 825 activated carbon filter for the filtering function See Special Accessories Fix the deflector with two screws D3 5x6 5 Fig 2 Fig 2 20 Electrical connections Safety warnings for electrician It must be ensured that the voltage and current indicated on the rating plate agree with the voltage of the user to electricity supply Ifthe appliance has been equipped with a mains lead with a moulded on type plug the following regulations must be comply with The plug moulded on to the lead incorporates a fuse For replacement use a 5 amp BS1362 fuse Only ASTA approved or certified fuses should be used If the fuse cover carrier is lost a replacement cover carrie must be obtained from an electrical goods retailer If the socket outlets are not suitable for the plug fitted to the appliance then the plug must be cut off and destroyed for safety reasons and an appropriate plug be fitted When wiring the plug ensure that all strands of wire are securely retained in each te
5. 825 D 8259 D Dunstabzugshaube Fume Extractor Hood Hotte aspirante Afzuigkap Cappa aspirante Montage und Gebrauchsanweisung Installation and Operating Instructions Instructions de montage et mode d emploi Montage en gebruiksaanwijzing Istruzioni di montaggio ed istruzioni per l uso AtTroppogntnpas U paTpuuwv Contents Introduction Extractor version Filter version Electrical connections Safety warnings for electrician Technic Details Installation Safety warnings for kitchen unit installer Installation Hood Operation Safety warnings for user Maintenance and care Metal grease filter Open the metal grease filter Carbon filter Changing the light bulb Cleaning Special accessories Technical assistance service Printed on recycled paper AEG putting words into action 18 23 24 24 26 28 28 8 32 33 33 33 Introduction Extractor version The hood is supplied as an extractor unit and can also be used with a filtering function by fitting activated carbon filters special accessory You will need original AEG activated carbon filters for this function see Special Accessories The air is forced out through a hose fitted to the top of the hood A Fig 1 The outlet hose must have a diameter of 120 mm special accessory for the filtering version Fit the connection ring above the hood with two screws then fir an exhausting pipe long enough to reach the
6. cifies a maximum depression of 0 04 bar in such rooms 24 Hoods can only be used safely with appliances connected to a chimney if the room and or flat air environment combination is ventilated from outside using a suitable ventilation hole approximately 500 600 cm large to avoid the possibility of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Since the rule for rooms with fuel burning appliances is outlet hole of the same size as the ventilation hole a hole of 500 600 cm which is to say a larger hole could reduce the performance of the extractor hood If the hood is used in its filtering function it will operate simply and safely in the above conditions without the need for any of the aforementioned measures When the hood is used in its extractor function the following rules must be followed to obtain optimal operation short and straight outlet hose keep bends in outlet hose to a minimum never install the hoses with an acute angle they must always follow a gentle curve only keep the hose as large as possible 120 mm min Failure to observe these basic rules will drastically reduce the performance and increase the noise levels of the extractor hood 25 Installation Fig 3 26 Put the template onto the wall 1 and drill wo 12mm holes 2 Fit two
7. ety warnings for kitchen unit installer When used as an extractor unit the hood must be fitted with a 120mm diameter hose If the fumes must be forced out through the wall you must obtain a MKZ sizable wall exhaust pipe with external exhaust and air intake E Nr 610 899 004 120 mm which is one of our optional parts When installing the hood make sure you respect the following minimum distance from the top edge of the cooking hob ring surfaces electric cookers 600 mm gas cookers 650 mm coal and oil cookers 700 mm min The air outlet must not be connected to chimney flues or combustion gas ducts The air outlet must under no cir cumstances be connected to ventilation ducts for rooms in which fuel burning appliances are installed lt is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct The air outlet installation must comply with the regulations laid down by the relevant authorities When the unit is used in its extractor version a sufficiently large ventilation hole must be provided with dimensions that are approximately the same as the outlet hole National and regional building regulations impose a number of restrictions on using hoods and fuel burning appliances connected to a chimney such as coal or oil room heaters and gas fires in the same room The national decree on fuel burning systems spe
8. located on the unit s front panel the light switch switches the hood lamp on and off the motor switch switches the cooking smoke and vapour extractor motor on and off enabling you to select one of the three different speeds plus an intensive set Motor power adjustable to 3 positions plus an intensive set Light switch ON OFF 28 Safety warnings for user AN Never leave a cooking hob or ring on without a pot or pan on top of it to avoid the possibility of excess heat damaging the unit Gas oil or coal cooker flames in particular should never be left uncovered Special care should be taken when using deep fat fryers since the oil in them can overheat and burst into flames The risk of a fat fire increases when using dirty oil It is extremely important to note that overheating can cause a fire Never carry out any flamb cooking under the hood Always disconnect the unit from the power supply before carrying out any work on the hood including replacing the light bulb take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker t is very important to clean the hood and replace the filter at the recommended intervals Failure to do so could cause grease deposits to build up causing a fire hazard 29 Maintenance and care The hood must always be disconnected from the mains power supply before beginning any maintenance work
9. on filter should be changed once every four months Mounting Fig 5 Fit one carbon filter on the left and one on the right so to cover the plastic grids that protect the fan wheel then turn clockwise the central handle of the carbon filter Fig 5 To dismount proceed in reverse order Always specify the hood model code number and serial number when ordering replacement filters This information is shown on the registration plate located on the inside of the unit The activated carbon filter can be ordered from the AEG technical assistance service 31 Warning Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard You are therefore strongly recommended to follow these instructions The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Changing the light bulb 32 Disconnect the unit from the mains power supply Remove the lamp cover Replace the old light bulb with a new light bulb 40 W max Fit the lamp cover on its seat If the light does not come on make sure the bulb has been screwed in correctly before contacting the technical assistance service Cleaning Warning always disconnect the hood from the mains power supply before cleaning it Never insert pointed objects in
10. rminal Do not forget to fighten the mains lead clamp on the plug Electrical connections 230 V using fixed power supply line with plug 240 V using fixed power supply line Great Britain Fuse rating 13 amps The unit should only be connected up by an authorized electrician See rating plate for further information It is recommended that the socket for the plug is sited above the cooker hood or above the overhead cabinet This has 2 advantages 1 The socket is not visible 2 The appliance can easily be unplugged when necessary If a fixed connection is required the cooker hood should be connected by an electrical installer registered with a competent electricity company An isolating device is to be provided on the fixed wiring side Switches with a contact opening of more than 3mm apply as isolating devices These include automatic cutout switches fuses and contactors VDE 0730 s 7 Partl Electrical connection for the UK Appliances with 2 wires 22 The appliance must be connected to fixed wiring with a double pole switched fused spur outlet with or without pilot lamp We strongly recommend the appliance to be connected only by a qualified electrician who is a member of the NICEIC who will com ply with the IEE and any local regulations NOTE The terminology DOUBLE POLE means that both the live and the neutral supplies are switched and disconnected at the same time The terminations labelled
11. the motor s protective grid Wash the outside surfaces using a delicate detergent solution Never use caustic detergents or abrasive brushes or powders Only ever clean the switch panel and filter grille using a damp cloth and delicate detergents lt is extremely important to clean the unit and change the filters at the recommended intervals Failure to do so will cause grease deposits to build up that could constitute a fire hazard Special accessories MKZ telescopic wall pipe E Nr 610 899 004 outlet hose ABS120 120 mm 942 118611 Carbon filter KFF 942 118 627 Technical assistance service You are welcome to telephone our technical assistance service see list of technical assistance centres whenever you need information or in the unlikely event of a fault When calling please be ready to specify 1 The model code number 2 The serial number E Nr 3 The manufacturing number F Nr This information is shown on the registration plate inside the unit behind the grease filter grille We reserve the right to change specifications and colours as a result of our policy of continuing technological development 33