Home
Acu-Rite 2048 Weather Radio User Manual
Contents
1. gt R ITE Instruction Manual Weather Station model 02048 35 CONTENTS Unpacking Instructions 2 Backlight Settings 8 Package Contents 2 Placement Guidelines 9 Product Registration 2 Using the Weather Station 10 Features amp Benefits Sensor 2 Troubleshooting 0 11 Features amp Benefits Display 3 Care amp Maintenance 13 6 Intelli Time Battery 13 Sensor SCD ee 6 5 14 Display 56 7 FCC Information 14 Intelli Time 8 Customer Support 15 Set the Time Date Units 8 eee 15 Questions Contact Customer Support at 877 221 1252 or visit www AcuRite com SAVE THIS MANUAL FOR FUTURE REFERENCE ACU RITE Congratulations on your new AcuRite product To ensure the best possible product performance please read this manual in its entirety and retain it for future reference Unpacking Instructions Remove the protective film that is applied to the LCD screen prior to using this product Locate the tab and peel off to remove Package Contents 1 Display unit with tabletop stand 2 Power adapter 3 Outdoor sensor A Instruction Manual IMPORTANT tcceive wa
2. heat sources or vents Display unit and outdoor sensor must be within 330 ft 100 of each other e To maximize wireless range place units away from large metallic items thick walls metal surfaces or other objects that may limit wireless communication To prevent wireless interference place both units at least 3 ft 9 m away from electronic devices TV computer microwave radio etc NL MA F3 feet feet 9 m ZE APART 330 feet maximum a 100 meters Setup is Complete The sensor will now synchronize with the display unit It may take a few minutes for synchronization to complete Please refer to the troubleshooting section of this manual if anything appears to be functioning improperly 9 OPERATION Using the Weather Station Learning Mode Self Calibrating Forecasting uses a unique algorithm to analyze changes in pressure over a time period called Learning Mode to determine your altitude After 14 days the Learning Mode icon disappears from the display screen At this point the self calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction Weather Forecast AcuRite s patented Self Calibrating Forecasting provides your personal forecast of weather conditions for the next 12 to 24 hours by collecting data from the sensor in your backyard It generates a forecast with pinpoint accuracy personalized for your exact location
3. GE Outdoor 1 to 99 RH Indoor 1 to 99 RH WIRELESS RANGE 330 ft 100 m depending on home construction materials OPERATING FREQUENCY 433 MHz Display 5vdc power e 3 x AA alkaline batteries optional Sensor 2 AA alkaline or lithium batteries Outdoor 16 second updates Indoor 60 second updates FCC Information TThis device complies with part 15 of FCC rules Operation is subject to the following two conditions 1 This device may NOT cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications to this unit not snl approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user i
4. RAIN SNOW SNOW LIGHT RAIN CLOUDY PARTLY MIX LIKELY LIKELY LIKELY CLOUDY windy 9 TG 7 So Lightning Stormy View the complete list of icons at www AcuRite com acurite icons Subtle variations in barometric pressure greatly impact the weather This weather center displays the current pressure and indicates the direction the pressure is trending FALLING STEADY or RISING Humidity Level Indicator The Humidity Level Indicator easily conveys a low or high indoor humidity level for your home and health Learn more at http www acurite com humidity health Troubleshooting If the wireless signal indicator shows no bars Relocate the display unit and or the outdoor sensor The units must be within 330 ft 100 m of each other Make sure both units are placed at least 3 feet No outdoor sensor 9 m away from electronics that may interfere with reception the wireless communication such as TVs microwaves if no bars computers etc Use standard alkaline batteries or lithium batteries in sensor when temperature is below 4 F 20 C Do not use heavy duty or rechargeable batteries NOTE It may take up to 20 minutes for display unit and sensor to synchronize after batteries are replaced Flashing of the outdoor temperature is generally an indication of wireless interference 1 Bring both the sensor and display unit indoors and Outdoor remove batteries from each temperature Make sure the A B C s
5. aced see page 13 Once the new battery is installed time and date will need to be set manually If your AcuRite product does not operate properly after trying the troubleshooting steps visit www AcuRite com or call 877 221 1252 for assistance 12 Care amp Maintenance Display Unit Care Clean with a soft damp cloth Do not use caustic cleaners or abrasives Keep away from dust dirt and moisture Clean ventilation ports regularly with a gentle puff of air Outdoor Sensor Care Clean with a soft damp cloth Do not use caustic cleaners or abrasives Replace Intelli Time Clock Battery Intelli Time technology is powered by a pre installed coin cell battery that stores the time and date settings The battery has a shelf life of several years To replace the Intelli Time battery 1 Locate the coin cell battery compartment door on the back of the display unit Unscrew and remove the compartment cover 2 Insert 1 x CR2032 coin cell battery into the battery compartment as shown Install battery with positive terminal facing OUT 3 Screw in the battery cover WARNING THIS PRODUCT CONTAINS A BUTTON CELL BATTERY IF SWALLOWED IT COULD CAUSE SEVERE INJURY OR DEATH IN JUST 2 HOURS SEEK MEDICAL ATTENTION IMMEDIATELY IF INGESTED lt POISON POISON X9 13 Specifications TEMPERATURE RANGE Outdoor 40 F to 158 F 40 C to 70 C Indoor 32 F to 122 F 0 C to 50 C HUMIDITY RAN
6. claims Chaney Instrument Co 965 Wells St Lake Geneva WI 53147 15 ACU RITE Weather Temperature Weather Kitchen Clocks Stations amp Humidity Alert Radio Thermometers amp Timers Its more than accurate It S ACU RITE AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Chaney Instrument Co All rights reserved AcuRite is a registered trademark of the Chaney Instrument Co Lake Geneva WI 53147 All other trademarks and copy rights are the property of their respective owners AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 02048 INST 111914
7. ess again to dim to 30 press a 3rd time to enter AUTO DIM mode AUTO DIM appears below time AUTO DIM MODE Automatically adjusts display brightness based on time of day amp year MARCH 11 NOVEMBER 4 6 00 a m 9 00 p m 100 brightness 9 01 p m 5 59 a m 30 brightness NOVEMBER 5 MARCH 10 7 30 a m 7 00 p m 100 brightness 7 01 p m 7 29 a m 30 brightness Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding environmental conditions Proper placement of both the display unit and outdoor sensor are critical to the accuracy and performance of this product Display Unit Placement Place the display unit in a dry area free of dirt and dust Display unit stands upright for tabletop use or is wall mountable Outdoor Sensor Placement Sensor must be placed outside to observe outdoor conditions Sensor is water resistant and is designed for general outdoor use however to extend its life place the sensor in an area protected from direct weather elements 9 Hang the sensor using the integrated hang holes or hanger or by using string not included to hang it from a suitable location like a well covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To ensure accurate temperature measurement place units out of direct sunlight and away from any
8. hium batteries for the best product performance Heavy duty or rechargeable batteries are not recommended The sensor requires lithium batteries in low temperature Install Batteries 2 AA batteries conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the sensor for temperatures below 4 F 20 C 1 Slide off the battery compartment cover Take note of the A B C switch setting inside the battery compartment 2 Insert 2 x AA batteries into the battery compartment as shown Follow the polarity diagram in the battery compartment 3 Replace the battery cover A B C Switch set to match display unit LITHIUM Po BATTERIES iai IKA 70 C 1580F ar hd eo 1580F ALKALINE BATTERIES 6 Display Unit Setup Set the A B C Switch Install or Replace Backup Locate the A B C switch inside Batteries optional the battery compartment Set 1 Remove the battery the A B C switch to A B or C compartment cover You must select the same letter 2 Insert 3 x AA alkaline choices for both the display unit and the sensor in order for the units to synchronize batteries into the battery compartment as shown Follow the polarity diagram in the battery 2 Plug in Power Adapter compartment For the best performance plug 3 in the power adapter as the main power source for this product Replace the battery cover A B C Switch
9. ly to you Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law By acceptance of any of Chaney s products Chaney Instrument Co warrants that all products it manufactures the purchaser assumes all liability for the consequences arising warranty benefits to be of good material and workmanship and to be free of from their use or misuse No person firm or corporation is defects when properly installed and operated for a period of authorized to assume for Chaney any other liability in connection one year from the date of purchase Remedy for breach of this with the sale of its products Furthermore no person firm or warranty is limited to repair or replacement of the defective corporation is authorized to modify or waive the terms of this item s Any product which under normal use and service is paragraph and the preceding paragraph unless done in writing proven to breach the warranty contained herein within ONE and signed by a duly authorized agent of Chaney This warranty YEAR from date of sale will upon examination by Chaney gives you specific legal rights and you may also have other and at its sole option be repaired or replaced by Chaney rights which vary from state to state Transportation costs and charges for returned goods shall be paid for by the purchaser Chaney hereby disclaims all responsibility for such transportation costs and charges This For in warranty
10. rranty service PRODUCT REGISTRATION to receive year warranty protection www AcuRite com Register a Product Features amp Benefits OUTDOOR SENSOR 1 Integrated Hanger For easy placement 2 2 Wireless Signal Indicator Flashes when data is being sent to the display unit 3 Battery Compartment 4 A B C Switch ID code that must match display s A B C switch to ensure units synchronize 5 Battery Compartment Cover Features amp Benefits BACK OF DISPLAY UNIT 6 9 Integrated Hang Hole for easy wall mounting Reset Full reset to factory defaults A B C Switch ID code that must match tower sensor s A B C switch to ensure units synchronize Battery Compartment 10 Plug in for Power Adapter Battery Compartment Cover 4 11 Bh NS TL FORECAST o aie Le FRONT OF DISPLAY UNIT 12 A Button for setup preferences 13 2 Button for setup preferences 14 VV Button for setup preferences 15 Momentary Backlight Button Lights display for 7 seconds only applicable while on battery power Features amp Benefits ce i a j T So oS ger ph FOR S g h it j A ra A eas bi Se gale Pal ni et ts Me ime a Fn Ta TIa a Serre ke ga Z r Tia i fall f Le r a alay ae DISPLAY UNIT FRONT Curren
11. s encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help NOTE The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user authority to operate the equipment This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two confitions 1 This device may not cause and 2 This device must accept any interference received including interference that may cause undesired operation of the device 14 Customer Support AcuRite customer support is committed to providing you with best in class service For assistance please have the model number of this product available and contact us in any of the following ways O 877 221 1252 info chaney inst com 24 7 support at www AcuRite com gt Installation Videos gt Register your Product gt Instruction Manuals gt Support User Forum gt Replacement Parts gt Submit Feedback amp Ideas IMPORTANT oreert warranty service PRODUCT REGISTRATION Register online SUPPORT to receive year warranty protec
12. set to match sensor Install Backup Batteries 3 AA batteries optional 1 ee O ms Pe 3 x f A g Dy IMPORTANT Batteries are a backup power source to preserve records in the event of a power outage 2 Plug in Power Adapter Power adapter is recommended as the primary power source to enjoy the full functionality of this product BATTERY SAFETY Clean the battery contacts and also those of the device prior to battery installation Remove batteries from equipment which is not to be used for an extended period of time Follow the polarity diagram in the battery compartment Promptly remove dead batteries from the device Dispose of used batteries properly Only batteries of the same or equivalent type as recommended are to be used DO NOT incinerate used batteries DO NOT dispose of batteries in fire as batteries may explode or leak DO NOT mix old and new batteries or types of batteries alkaline standard DO NOT use rechargeable batteries DO NOT recharge non rechargeable batteries DO NOT short circuit the supply terminals PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS 7 Intelli Times Clock Intelli Time products are pre programmed with the correct time and date All you need to do is select your Time Zone and Daylight Saving Time preferences The clock will then a
13. t Outdoor Temperature Arrow icon indicates direction temperature is trending 12 to 24 Hour Weather Forecast Self Calibrating Forecasting pulls data from the outdoor sensor to generate your personal forecast Current Indoor Temperature Arrow icon indicates direction temperature is trending Moon Phase Display Low Battery Indicator AUTO DIM Indicator see page 8 Intelli Timeo Clock Automatically updates for Daylight Saving Time Date Current Indoor Humidity Arrow icon indicates direction humidity is trending 10 Humidity Level Indicator Indicates a high or low indoor humidity level 11 Learning Mode Icon Disappears after weather forecast self calibration is complete 12 Barometric Pressure Arrow icon indicates direction pressure is trending 13 Current Outdoor Humidity Arrow icon indicates direction humidity is trending 14 Heat Index Displays Heat Index calculation when temperature is 80 F 27 C or above 15 Sensor Low Battery Indicator 16 Outdoor Sensor Signal Strength 17 Dew Point Displays Dew Point calculation when temperature is 79 F 26 C or below 0 Set the A B C Switch The A B C switch is located inside the battery compartment It can be set to A B or C However you must select the same letter choices for both the sensor and the display unit in order for the units to synchronize Install or Replace Batteries AcuRite recommends high quality alkaline or lit
14. tion y e www AcRite com pRegister a Product Limited One Year Warranty At AcuRite we proudly uphold our commitment warranty will not be breached and Chaney will give no credit for products it manufactures which have received normal wear to quality technology Chaney Instrument Co and tear been damaged including by acts of nature tampered warrants that all products it manufactures to abused improperly installed damaged in shipping or repaired be of good material and workmanship and to or altered by others than authorized representatives of Chaney be free of defects when properly installed and The above described warranty is expressly in lieu of all other operated fora period of one year from the date warranties express or implied and all other warranties are of purchase hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty We recommend that you visit us at a a particular purpose Chaney expressly disclaims e all liability for special consequential or incidental damages www AcuRite com for the fastest Wy to register tort or by paeroa from any breach of this your product However product registration warranty Some states do not allow the exclusion or limitation does not eliminate the need to retain your of incidental or consequential damages so the above limitation original proof of purchase in order to obtain or exclusion may not app
15. utomatically update for Daylight Saving Time Set the Time Date amp Units Press and HOLD the 4 button to enter SETUP MODE Once in setup mode the preference you are currently setting will blink on the display To adjust the currently selected flashing item press and release the or WV buttons press and HOLD to fast adjust To save your adjustments press and release the button again to adjust the next preference The preference set order is as follows TIME ZONE PST MST CST EST AST HAST AKST DST Daylight Saving Time ON or OFF CLOCK HOUR CLOCK MINUTE CALENDAR DATE CALENDAR MONTH CALENDAR YEAR TEMPERATURE SCALE F or C BAROMETRIC PRESSURE SCALE inHg or hPa If you live in an area that observes daylight saving time DST should be set to ON even if it is not currently Daylight Savings Time You will automatically exit SETUP MODE if no buttons are pressed for 20 seconds Enter setup mode at any time by pressing the gg button Backlight Settings This weather station s color display features three different lighting settings High 100 brightness Medium 60 brightness and Low 30 brightness Using battery power alone the backlight is available momentarily for 7 seconds by pressing the Momentary Backlight button When display is powered with the power adapter backlight remains on at 100 brightness Press the Momentary Backlight button once to dim to 60 brightness pr
16. witch on both units match is flashing or Reinstall batteries in the outdoor sensor showing dashes Reinstall batteries in the display unit Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection Sometimes changing to a different channel can help Weather Forecast icon predicts conditions for the next 12 to 24 hours not current conditions Has Learning Mode icon disappeared from the display unit Learning Mode must complete before forecast and pressure will be accurate Allow unit to run continuously for 33 days Battery removal or resetting the display unit will restart Learning Mode After 14 days forecast should be fairly accurate however Learning Mode calibrates for a total of 33 days Inaccurate forecast Make sure both the display unit and sensor are placed Inaccurate out of direct sunlight and away from any heat sources or temperature vents see page 9 or humidity Make sure both units are positioned away from moisture sources see page 9 Troubleshooting Continued Check that the batteries are installed correctly Batteries may need to be replaced Reset the display by pressing the reset button located on the back of the display unit Date and time will need to be entered after a reset Display screen not working The unit lost power or batteries were changed and the time is not correct The Intelli Time battery needs to be repl
Download Pdf Manuals
Related Search
Related Contents
10A~30A Eye tracking research applications: Three case studies ESR9850 User Manual Maintenance et service Manuel d`entretien Home Decorators Collection 60025 Installation Guide HP Q153090901 User's Manual 陸 上 自 衛 隊 仕 様 書 T。SH ーBA 東芝ネオバ-ルベンダン ト取扱説明書 2010 年度版 情報科学室利用ガイド SHフィギュアーツ 仮面ライダー龍騎&ドラグレッダーセット 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file