Home

Craftsman 139.53925DS Owner`s manual

image

Contents

1. Sensor de seguridad de reversa Sensor de seguridad de reversa 29 OPERACION INSTRUCCIONES DE SEGURIDAD IMPORTANTES A ADVERTENCIA Para reducir el riesgo de LESIONES GRAVES o LA MUERTE LEA Y RESPETE TODAS LAS ADVERTENCIAS E INSTRUCCIONES SIEMPRE conserve los controles remotos lejos del alcance de los ni os NUNCA permita que los ni os operen o jueguen con los botones del control del abre puertas de garaje ni con los controles remotos SOLO active el abre puertas de garaje siempre y cuando est a plena vista correctamente calibrado y no haya ninguna obstrucci n en el recorrido de la puerta Tenga SIEMPRE la puerta del garaje a la vista hasta que est completamente cerrada NADIE DEBE ATRAVESAR EL RECORRIDO DE LA PUERTA CUANDO ESTA EN MOVIMIENTO NO DEJAR PASAR A NADIE POR DEBAJO DE UNA PUERTA DE GARAJE DETENIDA NI PARCIALMENTE ABIERTA De ser posible use el desenganche de emergencia para soltar el trole SOLO cuando la puerta del garaje est CERRADA Si los resortes est n debilitados o rotos o si la puerta est desbalanceada podr a caerse r pida e inesperadamente NUNCA use la manija del desenganche de emergencia a menos que la entrada al garaje est libre de obstrucciones y no haya ninguna persona en el camino NUNCA use la manija para abrir o cerrar la puerta Si el nudo de la cuerda se desatara usted podr a caerse C mo usar su abridor de puerta d
2. El sensor del sistema de retroceso de seguridad debe estar instalado y alineado correctamente antes de que el abridor de la puerta de cochera mueva la puerta hacia abajo INFORMACI N IMPORTANTE CON RESPECTO AL SENSOR DEL SISTEMA DE RETROCESO DE SEGURIDAD Si se instala y se alinea correctamente el sensor del sistema de retroceso de seguridad detectar cualquier obst culo que se cruce en el recorrido del rayo electr nico El ojo emisor el que tiene la luz indicadora de color mbar env a un rayo electr nico invisible al ojo receptor el que tiene la luz indicadora de color verde Si alg n objeto obstruyera este rayo invisible mientras la puerta se est cerrando la puerta se detendr autom ticamente retroceder hasta abrirse por completo y la luz del abridor parpadear diez veces Estos sensores se deben instalar en el interior de la cochera de manera que el ojo emisor y el ojo receptor est n uno frente al otro a ambos lados de la puerta y a una distancia m xima de 15 cm 6 pulg del piso Ambos sensores se pueden instalar en cualquiera de los dos lados de la puerta ya sea el derecho o el izquierdo siempre y cuando nunca le d el sol directamente a la lente del ojo receptor 44 ADVERTENCIA Cerci rese de que la energ a el ctrica no est conectada al abridor de la puerta de la cochera ANTES de instalar el sensor del sistema de retroceso de seguridad Para evitar una LESI N GRAVE o INCLUSO LA MUERTE cuando
3. 12 Install the header bracket 0 005 13 Attach the rail to the header bracket 14 Install the Protector System 15 17 Position the opener 00 c eee eee 18 Hang the opener 0 00 eee ee 19 Install the door control 2000000 eee 20 Electrical requirements 000 00 eee 21 Complete safety reversing sensor installation 21 Install the lights 0 00 0 eee ee 22 Attach the emergency release rope and handle 22 Fasten the door bracket o oooooo 23 24 Connect the door arm to the trolley 25 26 INTRODUCTION Safety Symbol and Signal Word Review Adjustment 27 29 Adjust the travel limits o o oo o 27 Adjust the force 0 0 02 e eee ee 28 Test the safety reversal system 29 Test the Protector System 005 29 Operation 30 34 Operation safety instructions o o o o 30 Using your garage door opener 30 Using the wall mounted door control 31 To open the door manuallY 31 Care of your opener 6 eee 32 Having a problem 2 0 ee eee 33 Diagnostic chart 1 2 0 0 0 cece eee ee 34 Programming 35 36 To add or reprogram a hand held remote control 35 To erase all codes from motor unit memory 35 3 Button remotes 0 0 0 0 cece ee ee
4. Unidad del motor Puerta de Control de puerta acceso montado en pared O EN POSICI N CERRADA LA Sensor de seguridad de reversa no debe ser mayor de 6 mm 1 4 de pulg Sensor de y pulg Cuerda y manija seguridad de reversa Brazo curvo del sistema de de la puerta liberaci n de emergencia la puerta recto Puerta de la cochera delantera PUERTA DE UNA PIEZA CON CARRIL EN POSICION CERRADA M nsula del riel Trole Puerta de Pared acceso delantera M nsula del cabezal Brazo de de la ij Puerta la puerta recto Cuerda y manija dela puerta del sistema de cochera CE liberaci n de emergencia AA Sensor de seguridad de reversa E La separaci n entre el piso y la puerta Sensor de seguridad no debe ser mayor de 6 mm 1 4 de pulg de reversa ort Inventario de las caja de cart n Su abridor viene empacado en una caja de cart n que contiene DESTRUYA EL HULE ESPUMA Toda la torniller a y las piezas el motor y las piezas que se muestran en la siguiente ilustraci n necesarias para el montaje e instalaci n de su puerta se ilustran Tome nota de que los accesorios depender n del modelo que en la siguiente p gina Conserve la caja y los materiales de haya comprado Si falta alguna pieza revise con cuidado e
5. Bolts 5 16 18x7 8 Nuts 5 16 18 Bolts 5 16 18x7 8 Q Cut this end ALL ONE PIECE DOORS 1 Assemble the door arm Figure 4 e Fasten the straight and curved door arm sections together to the longest possible length with a 2 or 3 hole overlap e With the door closed connect the straight door arm section to the door bracket with the 5 16 x1 1 4 clevis pin e Secure with a ring fastener 2 Adjustment procedures Figure 5 e On one piece doors before connecting the door arm to the trolley the travel limits must be adjusted Limit adjustment screws are located on the left side panel as shown on page 27 Follow adjustment procedures below e Open door adjustment decrease UP travel limit Turn the UP limit adjustment screw counter clockwise 4 turns Press the Door Control push button The trolley will travel to the fully open position Manually raise the door to the open position parallel to the floor and lift the door arm to the trolley The arm should touch the trolley just in back of the door arm connector hole Refer to the fully open trolley door arm positions in the illustration If the arm does not extend far enough adjust the limit further One full turn equals 2 5 cm of trolley travel e Closed door adjustment decrease DOWN travel limit Turn the DOWN limit adjustment screw clockwise 4 complete turns Figure 5 inner Tralley Outer Trolley Closed Door Inner Trolley
6. Open Door Emergency Release Handle SSS Trolley Q Ring Fastener Clevis Pin Straight 5 16 x1 1 4 Arm Bolts 5 16 18x7 8 Curved Figure 4 Door Arm Press the Door Control push button The trolley will travel to the fully closed position Manually close the door and lift the door arm to the trolley The arm should touch the trolley just ahead of the door arm connector hole Refer to the fully closed trolley door arm positions in the illustration If the arm is behind the connector hole adjust the limit further One full turn equals 2 5 cm of trolley travel 3 Connect the door arm to the trolley e Close the door and join the curved arm to the connector hole in the trolley with the remaining clevis pin It may be necessary to lift the door slightly to make the connection e Secure with a ring fastener e Run the opener through a complete travel cycle If the door has a slight backward slant in full open position as shown in the illustration decrease the UP limit until the door is parallel to the floor NOTE When setting the up limit on the following page the door should not have a backward slant when fully open as illustrated below A slight backward slant will cause unnecessary bucking and or jerking operation as the door is being opened or closed from the fully open position Closed Door 9 e a Correct Angle Door Arm EN ue 0 iS aint wig tO Esp 0 0 0 0
7. 6 pulg del piso e Fije la m nsula a la pared con tornillos de cabeza cuadrada no se incluyen e Si esta usando m nsulas de extensi n o bloques de madera por la falta de espacio aseg rese de que las dos unidades queden a la misma distancia de la superficie de montaje Asimismo aseg rese de que no haya ninguna obstrucci n Instalaci n en el piso Figura 4 e Use bloques de madera o m nsulas de extensi n vea Accesorios para elevar las m nsulas de los sensores de manera que las lentes queden a una distancia m xima de 15 cm 6 pulg del piso e Cuidadosamente mida e instale las unidades derecha y izquierda a la misma distancia con respecto a la pared Aseg rese de que no haya ninguna obstrucci n e Fije al piso las m nsulas para los sensores con los sujetadores para cemento como se muestra en la ilustraci n ESTAS PIEZAS SE MUESTRAN EN SUTAMA O REAL m OP A Perno de coche de Tuerca mariposa de Grapas 1 4 20x1 2 de pulg 1 4 de pulg 20 16 Figura 1 y Figura 2 Figura 3 sensor Suministrado con m nsula de sy extensi n Figura 4 MONTAJE DE GU A DE PUERTA LADO DERECHO M nsula te ana Ll inte del gor Luz Indicadora MONTAJE PARED LADO DERECHO Fije el pedazo de madera a la pared con tirafondos no incluidos M nsula Luz indicadora del sensor Tirafondos no incluida
8. Door Arm Cel59 Rail Assembly 00000000000 Door Bracket Straight Door Emergency Release Rope 8 Handle Carton Inventory Your garage door opener is packaged in one carton which PARTS MAY BE STUCK IN THE FOAM Hardware for contains the motor unit and all parts illustrated below Accessories will depend on the model purchased If assembly and installation is shown on the next page Save the carton and packing material until installation and anything is missing carefully check the packing material adjustment is complete SECURITY 3 Function Remote Control 2 The Protector System 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with attached 2 Conductor White amp White Black Bell Wire Rail Support A Braces a A 7 Remote Control 0 Visor Clip 0 d Sprocket Coupling SECURITY Keyless Entry Straight Door Arm Section Header Rail Brackets Curved Door Arm Section Safety Labels and Literature Safety Reversing Sensor Mounting Bracket 2 Hardware Inventory Separate all hardware and group as shown below for the assembly and installation procedures ASSEMBLY HARDWARE O A fm Q e Metal Sleeve 2 C Clip 2 Hex bolt 1 4 20x7 16 14 Sprocket Coupling Sleeve Wire Clips 6 INSTALLATION HARDWARE m O O S Carriage A Wing Nut Ring Nut 5 16 18 6 1 4 20x1 2 1 4 20 2 Fastener 3 pii D 0000000 Lag Screw 5 16
9. To prevent possible SERIOUS INJURY or DEATH from electrocution e Be sure power is not connected BEFORE installing door control e Connect ONLY to 24 VOLT low voltage wires To prevent possible SERIOUS INJURY or DEATH from a closing garage door e Install door control within sight of garage door out of reach of children at a minimum height of 5 1 5 m and away from all moving parts of door e NEVER permit children to operate or play with door control push buttons or remote control transmitters e Activate door ONLY when it can be seen clearly is properly adjusted and there are no obstructions to door travel e ALWAYS keep garage door in sight until completely closed NEVER permit anyone to cross path of closing garage door Outside Keylock Accessory Connections To opener quick connect terminals white to white white red to red HARDWARE SHOWN ACTUAL SIZE DOOD Screw 6ABx1 1 4 Control Panel std installation Screw 6 32x1 Control Panel pre wired Insulated Staples Drywall Anchors PREMIUM CONTROL CONSOLE i Top Mounting Hole 5 Terminal Lighted Screws Push Button Bottom Mounting Hole Figure 1 Figure 2 REMOVE amp REPLACE COVER PRE WIRED INSTALLATION To Replace Insert Top Tabs First _ 24 Volt 2 Conductor Bell Wire Figure 3 Strip 7 16 11 mm of insulation from each wire Insert wires through opening on top o
10. cuatro veces cuando se la desactive ACCESORIOS 139 53702 Liberador de la llave de emergencia 139 53753 SECURITY Control remoto de Se requiere en las cocheras que NO tienen 3 funciones puerta de acceso Permite al due o de la casa Incluye el clip del visor abrir la puerta de la cochera manualmente desde el exterior desconectando el trole 139 53405 Extensi n del riel de 2 4 m 8 pies 1399398 ii remoto compacto Permite que una puerta de 2 4 m 8 pies se Con lazada para ponerse en el llavero abra completamente 0 139 53754 SECURITY Entrada sin llave 139 53589 M nsulas de soporte Permite al due o de la casa operar la puerta de la cochera desde el exterior ingresando una contrase a Tambi n puede agregarse una contrase a temporal para visitas o personal de servicio Para cielos rasos sin acabados o en los casos en que se necesite soporte adicional basado en la construcci n de la cochera Incluye las m nsulas y los sujetadores Consola de control con detecci n de movimiento La consola de control con detecci n de movimiento est equipada con sensores de movimiento que mantendr n la luz encendida durante cinco minutos cada vez que alguien entre al garaje El sensor se puede desactivar f cilmente cuando M nsulas para la altura de la puerta S lo para puertas seccionales Sustituyen a las m nsulas superiores y los rodillos de la puerta para reducir la altura del recorrido de la puerta P
11. e NUNCA intente aflojar mover ni ajustar la puerta de su cochera los resortes de la puerta los cables las poleas las m nsulas ni la torniller a pues todos estos elementos est n bajo tensi n EXTREMA e Quite TODOS los seguros y retire TODAS las cuerdas conectadas a la puerta de cochera ANTES de instalar y operar el abridor de la puerta de cochera para evitar que se enreden PRECAUCI N Para evitar que se da en el puerta y el abridor e SIEMPRE quite los seguros ANTES de instalar y o de operar el abridor SOLAMENTE opere el abridor de puerta de cochera con corriente de 120V 60Hz con objeto de evitar su mal funcionamiento y que el abridor se da e Herramientas necesarias Durante el montaje instalaci n y ajuste del abridor las instrucciones le indicar n c mo usar las herramientas que aparecen en la siguiente ilustraci n k Jh Sierra de mano ESA Martillo Cortadora de alambre Brocas de 3 16 5 16 y 5 32 de pulgada Escalera Llaves de t 1 2 a aves de tuercas 1 2 3 8 de pulgada IL Llave inglesa Pinzas Destornillador Planificacion Identifique la altura y el tipo de su puerta de cochera Revise el area de su cochera y observe si alguna de las siguientes instalaciones corresponden a la suya A veces se requieren materiales adicionales asi que tal vez sea conveniente tener esta hoja y las ilustraciones correspondientes a mano cuando inicie la instalaci n de su abridor D
12. n La luz del abridor parpadear dos veces Suelte el bot n 2 Oprima el nuevo PIN de cuatro d gitos y luego oprima Enter Las luces de la unidad del motor parpadear n una vez cuando el PIN se haya aprendido Pruebe oprimiendo el nuevo PIN luego oprima Enter La puerta debe moverse Para poner un PIN temporal Usted puede autorizar el acceso a sus visitas o a personal de servicio con un PIN temporal de cuatro d gitos Despu s de un determinado n mero de horas programadas o n mero de accesos este PIN temporal expira y no vuelve a abrir la puerta Se puede usar para cerrar la puerta a n despu s de que haya expirado Haga lo siguiente para poner un PIN temporal 1 Oprima los cuatro botones correspondientes a su PIN de entrada personal no el ltimo PIN temporal luego oprima y mantenga oprimido el bot n La luz del abridor va a parpadear tres veces Suelte el bot n 2 Oprima los cuatro d gitos del PIN temporal que haya elegido luego oprima Enter La luz del abridor va a parpadear cuatro veces 36 NOTA Este m todo requiere dos personas si la Entrada sin llave ya est montada fuera de la cochera 1 Introduzca un n mero de identificaci n personal PIN que haya elegido usando el teclado Luego oprima y mantenga oprimido el bot n ENTER 2 Mientras mantiene oprimido el bot n ENTER oprima y mantenga oprimido el bot n de la luz LIGHT de la Consola de Control Premiu
13. se cerrar con el control remoto manual Sin embargo la puerta se puede cerrar con el Control de la puerta el Interruptor de llave externo o la Entrada sin llave siempre y cuando los active hasta que el recorrido hacia abajo haya terminado Si los suelta demasiado pronto la puerta va a retroceder Las luces del abridor se encender n en los siguientes casos Siempre que conecte el abridor inicialmente cuando se restaura el suministro de energ a despu s de una interrupci n cuando el abridor se activa Las luces se apagan autom ticamente despu s de 4 minutos y 1 2 o se quedan encendidas cuando se activa Luz en la consola de control premium Los bombillos deben ser de A19 El poder de la bombilla es 100 m ximo de vatios La funci n de la luz del Security Las luces se encender n tambi n si alguien camina por la puerta de la cochera cuando est abierta Si tiene la consola de control premium esta funci n puede desactivarse como sigue Con las luces del abridor apagadas oprima y mantenga oprimido el bot n de la luz durante 10 segundos hasta que la luz se encienda y se apague de nuevo Para volver a activar esta funci n empiece el procedimiento con las luces encendidas luego oprima y mantenga oprimido el bot n de la luz durante 10 segundos hasta que la luz se apague y luego se encienda de nuevo C mo usar la unidad de control de pared LA CONSOLA DE CONTROL PREMIUM Oprima el bot n iluminado para abrir o
14. support on header wall or ceiling otherwise garage door might not reverse when required DO NOT install header bracket over drywall OPTIONAL CEILING MOUNT FOR HEADER BRACKET Header Wall Vertical Centerline of Garage Door Structural Supports e Concrete anchors MUST be used if mounting header bracket or 2x4 into masonry e NEVER try to loosen move or adjust garage door springs cables pulleys brackets or their hardware all of which are under EXTREME tension e ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An unbalanced garage door might not reverse when required Installation procedures vary according to garage door types Follow the instructions which apply to your door 1 Close the door and mark the inside vertical centerline of no D the garage door NN 2 Extend the line onto the header wall above the door You can fasten the header bracket within 4 1 22 m of the left or right of the door center only if a torsion spring or center bearing plate is in the way or you B sie Header Wall Z can attach it to the ceiling see page 13 when 1 3 7 5 om Track E clearance is minimal It may be mounted on the wall W 34 Hl a upside down if necessary to gain approximately 1 2 1 cm If you need to install the header bracket on a 2x4 Ha on wall or ceiling use lag s
15. 0 0 0 OO a AA r A Incorrect ADJUSTMENT STEP 1 Adjust the Travel Limits Limit adjustment settings regulate the points at which the door will stop when moving up or down To operate the opener press the Door Control push bar Run the opener through a complete travel cycle Does the door open and close completely e Does the door stay closed and not reverse unintentionally when fully closed If your door passes both of these tests no limit adjustments are necessary unless the reversing test fails Adjustment Step 3 page 29 Adjustment procedures are outlined below Read the procedures carefully before proceeding to Adjustment Step 2 Use a screwdriver to make limit adjustments Run the opener through a complete travel cycle after each adjustment NOTE Repeated operation of the opener during adjustment procedures may cause the motor to overheat and shut off Simply wait 15 minutes and try again If anything interferes with the door s upward travel it will stop If anything interferes with the door s downward travel including binding or unbalanced doors it will reverse HOW AND WHEN TO ADJUST THE LIMITS If the door does not open completely but opens at least 5 feet 1 5 m Increase up travel Turn the UP limit adjustment screw clockwise One turn equals 2 5 cm of travel If door does not open at least 5 feet 1 5 m Adjust the UP open force as explained in Adjustment Step 2 If the door d
16. 35 To add reprogram or change a Keyless Entry PIN 36 Repair Parts 37 38 Rail assembly parts 0 0 0 0 eee eee 37 Installation parts 2 2 eee 37 Motor unit assembly parts 00000 38 Accessories 39 Warranty 39 This garage door opener has been designed and tested to offer safe service provided it is installed operated maintained and tested in strict accordance with the instructions and warnings contained in this manual 4 amp WARNING Mechanical A WARNING Electrical CAUTION When you see these Safety Symbols and Signal Words on the following pages they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them The hazard may come from something mechanical or from electric shock Read the warnings carefully When you see this Signal Word on the following pages it will alert you to the possibility of damage to your garage door and or the garage door opener if you do not comply with the cautionary statements that accompany it Read them carefully Preparing your garage door Before you begin e Disable locks e Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding 1 Lift the door about halfway as shown Release the door If balanced it should stay in place supported entirely by its springs 2 Raise and lower the door to see if
17. Bulb power is 100 watts maximum Security light feature Lights will also turn on when someone walks through the open garage door With a Premium Control Console this feature may be turned off as follows With the opener lights off press and hold the light button for 10 seconds until the light goes on then off again To restore this feature start with the opener lights on then press and hold the light button for 10 seconds until the light goes off then on again Using the Wall Mounted Door Control fined THE PREMIUM CONTROL CONSOLE Press the lighted push button to open or close the door Press again to reverse the door during the closing cycle or to ie Button stop the door while it s opening Light feature Press the Light button to turn the opener light on or off It will not control the opener lights when the door is in motion If you turn it on and then activate the opener the light will remain on for 4 1 2 minutes Press again to turn it off sooner The 4 1 2 minute interval can be changed to 1 1 2 2 1 2 or 3 1 2 minutes as follows Press and hold the Lock button until the light blinks about 10 seconds A single blink indicates that the timer is reset to 1 1 2 minutes Repeat the procedure and the light will blink twice resetting the timer to 2 1 2 minutes Repeat again for a 3 1 2 minute interval etc up to a maximum of four blinks and 4 1 2 minutes Lock feature Designed to prevent operation of the door fr
18. Falla en el circuito del motor Cambie el receptor Tarjeta de l gica hacarlo funcionar Si aun as el motor no funciona cambie la tarjeta l gica S ntoma El motor no funcione e Cambie la tarjeta l gica ya que el motor en s raramente falla COMO PROGRAMAR EL ABRIDOR AVISO Si utiliza este abre puertas de garaje Security con un transmisor no dotado de un sistema de c digos de salto c digo aleatorio se ver n circunvenidas las medidas t cnicas incorporadas en el receptor del abridor para proteger contra los aparatos de captura de c digos El propietario de los derechos propiedad intelectual del abridor no autoriza ni al comprador ni al proveedor de un transmisor no dotado de un sistema de c digos de salto c digo aleatorio a circunvenir dichas medidas t cnicas Su abridor de puerta de cochera ya viene programado de f brica para operar con su control remoto manual La puerta se abrir y se cerrar cuando oprima el bot n grande A continuaci n se proveen las instrucciones para programar su abridor para que opere con controles remotos Security e adicionales C mo Agregar o Reprogramar un Control Remoto Manual C MO USAR EL BOT N LEARN APRENDER C MO USAR LA CONSOLA DE CONTROL PREMIUM 1 Oprima y suelte el bot n Aprender de la unidad del motor La lu
19. Figura 5 Tuerca mariposa de 1 4 de pulg 20 Sa i P Perno de coche de 1 4 20x1 2 de pulg Elemento ptico ESTAS PIEZAS SE MUESTRAN EN SU TAMA O REAL mw GO ff Perno de coche de 1 4 20x1 2 de pulg Tuerca mariposa de 1 4 de pulg 20 Grapas 17 Haz invisible de luz area protegida Sensor de reversa de seguridad INSTALACION PASO 5 Coloque el abridor en pxosici n PRECAUCI N Para evitar que la puerta del garaje sufra da os apoye el riel del abre puertas sobre un tirante de madera de 3 8 cm 2x4 pulg Siga las instrucciones correspondientes al tipo de puerta de su d 9 p P p colocado sobre la parte superior de la puerta garaje como se muestra en la ilustraci n PUERTA SECCIONAL O PUERTA DE UNA SOLA PIEZA CON RIEL DE GUIA Puede utilizar un tirante de madera de 3 8 cm 2x4 pulg acostado para determinar la distancia ideal entre la puerta y el riel e Quite el material de empaque e Levante el abre puertas y col quelo sobre una escalera Si la escalera no es lo suficientemente alta va a necesitar ayuda e Abra la puerta totalmente y apoye acostado un tirante de f y v madera de 3 8 cm 2x4 pulg sobre la parte superior de la puerta bajo el riel Puerta El tabl n de 3 8 cm 2x4 pulg e Sil ior de d se usa para determinar i la parte o el panel superior de la puerta toca el tro
20. La separaci n entre el piso y la puerta no debe ser mayor de 6 mm 1 4 de pulg A Detector de seguridad de reversa gt ss 0 i o z EE hpto Bo ile F A lar Control de puerta m Lid montado en pared AAA gt m L nea vertical del _ centro de la puerta 55 A A 4 y S5 obi er e A A eoo SA Y A 2 Y r Y o jo Detector ge e Observe el punto donde la puerta hace contacto con el piso El espacio entre la base de la puerta y el piso no debe exceder 6 mm 1 4 de pulgada Si no es asi se corre el riesgo de que el sistema de retroceso de emergencia no funcione correctamente Vea Ajustes Paso 3 Sera necesario reparar ya sea el piso o la puerta INSTALACION CON UNA PUERTA SECCIONAL e Si tiene una puerta de acero aluminio fibra de vidrio o con paneles de vidrio necesitar refuerzos verticales y horizontales en la puerta Instalaci n Paso 12 e El abridor se debe instalar por encima del centro de la puerta pero si existe alg n resorte de tensi n o placa de apoyo en el paso de la m nsula del cabezal se puede instalar hasta a 1 22 m 4 pies a la derecha o a la izquierda del centro de la puerta Vea Instalaci n Pasos del 1 al 12 e Si su puerta es de m s de 2 13 m 7 pies de altura vea Extensiones de riel en la secci n de Accesorios TECHO TERMINADO SS Es necesario m nsula de soporte y accesorios de fijaci n V ase la p gina 19 fore Unidad del motor Resort
21. de la cochera porque est desnivelado etc e Se hagan reparaciones o ajustes al abridor AJUSTES PASO 4 Pruebe la Sistema de Protecci n 44 ADVERTENCIA Si el sensor de retroceso de seguridad no se ha instalado e Oprima el bot n de la unidad de control remoto para abrir la debidamente las personas y los ni os peque os en particular puerta podr an sufrir LESIONES GRAVES o INCLUSO LA MUERTE cuando se cierra la puerta de la cochera e Coloque la caja de cart n del abridor en la trayectoria de la puerta e Oprima de nuevo el bot n de la unidad de control remoto para cerrar la puerta sta no se deber mover m s de una pulgada 2 5 cm y las luces del abridor empezaran a N A A A parpadear y 8 8 La puerta no se podr cerrar con ninguno de los controles remotos si las luces indicadoras de cualquiera de los sensores est n apagadas indic ndole que los sensores est n fuera de alineaci n o que existe alguna obstrucci n h A Si el abridor cierra la puerta cuando el sensor del sistema de Y A y retroceso de seguridad est obstruido y los sensores no est n a m s de 15 cm 6 pulg del piso llame a un t cnico especializado en sistemas de puertas ap D ID 3 qe r g g
22. del garaje Haz invisible de luz Sensor de seguridad de reversa 15 cm 6 pulg sobre el piso m ximo INSTALACION DE LAS MENSULAS Aseg rese de que el abridor no est conectado a la corriente el ctrica Instale y alinee las m nsulas de manera que los sensores est n uno frente al otro en los lados opuestos de la puerta a una distancia m xima de 15 cm 6 pulg del piso Instale las m nsulas de una de las tres maneras siguientes Instalaci n en el carril de la puerta de la cochera recomendada e Deslice los brazos curvos sobre la orilla redondeada de cada uno de los carriles de la puerta con los brazos curvos apuntando hacia la puerta Col quelos en su posici n contra el costado del carril Debe quedar ras con el reborde pegado a la orilla posterior del carril como se ilustra en la Figura 1 Si el carril de su puerta no soporta la m nsula firmemente se recomienda que la instale sobre la pared Instalaci n en la pared Figura 2 y 3 e Coloque la m nsula contra la pared con los brazos curvos apuntando hacia la puerta Cerci rese de que haya suficiente espacio para que el rayo del sensor no est obstruido e Si es necesario tener m s profundidad puede usar m nsulas de extensi n vea Accesorios o bloques de madera e Use los orificios de montaje de la m nsula para marcar y taladrar los 2 orificios de 3 16 de pulgada de di metro a cada lado de la puerta a una distancia m xima de 15 cm
23. del recorrido de la puerta cada vuelta completa del tornillo equivale a 5 cm 2 pulg del recorrido del trole Opere el abridor durante un ciclo completo del recorrido Si la puerta parece estar en cierto ngulo hacia atr s cuando est completamente abierta como se muestra en la siguiente ilustraci n disminuya el l mite del recorrido hacia e Ajuste de la puerta al cerrarla Disminuya el l mite del arriba hasta que la puerta quede paralela al piso recorrido HACIA ABAJO NOTA Al establecer el l mite hacia arriba como se indica en la Ajuste el tornillo para ajustar el l mite del recorrido HACIA p gina siguiente la puerta no debe tener una inclinaci n hacia ABAJO d ndole 4 vueltas completas hacia la derecha atr s cuando est totalmente abierta como se ilustra abajo Una ligera inclinaci n hacia atr s ocasionar que la puerta se pandee innecesariamente y o que la operaci n no sea uniforme al abrir o cerrar la puerta desde la posici n totalmente abierta Puerta Cerrada Trole interior Trole exterior Figura 5 Orificio conector del brazo de la puerta Brazo de la puerta Manija de emergencia Puerta cerrada Trole interior q exterior ngula correcto 6J Orificio conector a del brazo de la puerta j ngulo de la puerta Puerta abierta No es adecuado AJUSTES PASO 1 Ajuste el limite del recorrido HACIA ARRIBA y HACIA ABAJO Al ajustar el limite del recorri
24. door If it is unbalanced or binding call a trained door systems technician e Check to be sure door opens amp closes fully Adjust limits and or force if necessary see pages 27 and 28 e Repeat the safety reverse test Make any necessary adjustments see Adjustment Step 3 Once a Year e Oil door rollers bearings and hinges The opener does not require additional lubrication Do not grease the door tracks 32 THE REMOTE CONTROL BATTERY 4 amp WARNING To prevent possible SERIOUS INJURY or DEATH e NEVER allow small children near batteries e If battery is swallowed immediately notify doctor To reduce risk of fire explosion or chemical burn e Replace ONLY with 3V2032 coin batteries e Do NOT recharge disassemble heat above 100 C 212 F or incinerate The lithium battery should produce power for up to 5 years To replace battery use the visor clip or screwdriver blade to pry open the case as shown Insert battery positive side up Dispose of old battery properly Replace the battery with ONLY 3V2032 coin cell batteries Open this end first to avoid cracking housing NOTICE To comply with FCC and or Industry Canada rules IC adjustment or modifications of this receiver and or transmitter are prohibited except for changing the code setting or replacing the battery THERE ARE NO OTHER USER SERVICEABLE PARTS Tested to Comply with FCC Standards FOR HOME OR OFFICE USE Operation is
25. door if required for your installation Refer to the dotted line optional placement drawing Drill 3 16 pilot holes and substitute 5 16 x1 1 2 lag screws not provided to fasten the bracket to the door HARDWARE SHOWN ACTUAL SIZE Nut 5 16 18 Lock Washer 5 16 Carriage Bolt 5 16 18x2 1 2 _ Header Wall 2x4 Support Finished Ceiling Ls E E KIS y A te l AS Horizontal and vertical Header N reinforcement is needed for Bracket i lightweight garage doors i Door fiberglass aluminum steel Bracket door with glass panel etc Optional k not provided Placement of Door Bracket f i Vertical m Centerline of i Garage Door 5 16 18 eee i Top of Door j i Inside Garage EY Ky ace ssp la Ey S Optional E Placement Ey Ky KY a i i e eE S La f Carriage Bolt i E aa 5 16 18x2 1 2 Gr For a door with no exposed framing AA or for the optional installation use O 5 16 x1 1 2 lag screws not provided N to fasten door bracket 24 INSTALLATION STEP 13 Connect Door Arm to Trolley Follow instructions which apply to your door type as illustrated below and on the following page SECTIONAL DOORS ONLY Make sure garage door is fully closed Pull the emergency release handle to disconnect the outer trolley from the inner trolley Slide the outer trolley back away from the
26. e Aseg rese de que los sensores de seguridad est n instalados y alineados correctamente y que est n libres de obstrucciones Consulte la secci n Instalaci n Paso 10 Instale La Sistema de Protecci n e Compruebe los LED de diagn stico de la unidad del motor para ver si parpadean Luego consulte a tabla de diagn stico en la siguiente p gina El control remoto no activa la puerta Compruebe el control puerta de premium para ver si parpadea En caso afirmativo desactive el modo de bloqueo seg n las instrucciones sobre el uso del la Consola de Control Premium e Vuelva a programar el control remoto seg n las instrucciones Consulte la secci n sobre su programaci n e Si el control remoto sigue sin activar la puerta compruebe el LED de diagn stico de la unidad del motor para ver si parpadea luego consulte la tabla de diagn stico en la siguiente p gina La puerta invierte el movimiento sin ninguna raz n aparente ajuste la fuerza o los l mites del recorrido y repita la prueba de retroceso de seguridad Es normal tener que ajustar la fuerza y los l mites del recorrido peri dicamente Las condiciones atmosf ricas pueden afectar al recorrido de la puerta Compruebe manualmente si la puerta tiene problemas de equilibrado o si queda atascada e Consulte el apartado Ajustes Paso 2 Ajuste la fuerza La puerta se cierra completamente toca el suelo y se vuelve a abrir sin ning n motivo aparente ajuste
27. garaje Punto m s alto de recorrido de la puerta L nea vertical del centro de la puerta Cielo raso terminado ge PER L nea vertical del 77 Mensula centro de la puerta del cabezal y er ae gt 2 og Tirafondos de 5 16x9x1 5 8 de pulg 15 cm 6 pulg m ximo Pared frontal Puerta del garaje vertical del centro de la puerta INSTALACION PASO 3 Colocaci n del riel en la m nsula del cabezal e Coloque el abre puertas sobre el piso bajo la m nsula instalada Use el material del empaque como base para protegerlo NOTA Si el resorte de la puerta estuviera interfiriendo va a necesitar ayuda Otra persona tendr que sostener el abre puertas firmemente sobre un soporte provisorio hasta que el riel pase el resorte e Coloque la m nsula del riel contra la m nsula del cabezal e Proceda a alinear los agujeros de las m nsulas y nalas con una chaveta de 5 16x2 3 4 de pulg tal se muestra El espaciador se puede instalar a ambos del carril e Introduzca un anillo de seguro para terminar la uni n Pared frontal M nsula del cabezal M nsula del riel Seguro de anillo M nsula del cabezal Pasador chaveta de 5 16x2 3 4 de pulg Puerta del garaje Soporte provisorio ESTAS PIEZAS SE MUESTRAN EN SU TAMA O REAL Pasador chaveta de i 5 16x2 3 4 de pulg Seguro de anillo 14 INSTALACION PASO 4 Instale la Sistema de Protecci n
28. garaje Tuerca de 5 16 18 f Extremo de pulg i i superior de la i 1 1 puerta interior de la cochera M nsula de la puerta Orilla superior de la puerta Colocaci n opcional Perno de coche de 5 16 18 por 2 1 2 de pulg A A an ov i su puerta no tiene un marco exterior ae expuesto o en caso de que tenga que recurrir a la instalaci n opcional use tornillos de cabeza cuadrada de 5 16x1 1 2 de pulg para sujetar la m nsula de la puerta Estos tornillos no se incluyen 24 INSTALACION PASO 13 Conecte el brazo de la puerta al trole Siga las instrucciones que correspondan al tipo de puerta de cochera que usted tenga como se muestra a continuaci n y en la pagina siguiente SOLO PARA PUERTAS SECCIONALES e Cerci rese de que la puerta de la cochera est completamente cerrada Tire de la manija de emergencia para desconectar el trole exterior del trole interior Deslice el trole exterior hacia atr s en direcci n opuesta a la puerta por lo menos 5 cm 2 pulg como se indica en las Figuras 1 2 y 3 e Figura 1 Fije la secci n recta del brazo de la puerta al trole exterior usando un pasador de chaveta de 5 16x1 pulg Asegure la conexi n con el anillo sujetador Fije la secci n curva del brazo a la m nsula de la puerta de la misma manera con un pasador de chaveta de 5 16 por 1 1 4 de pulg e Fig
29. la fuerza o los l mites del recorrido y repita la prueba de retroceso de seguridad Es normal tener que ajustar la fuerza y los l mites del recorrido peri dicamente Las condiciones atmosf ricas pueden afectar al recorrido de la puerta e Consulte el apartado Ajustes Paso 1 Ajuste los l mites del recorrido hacia ARRIBA y hacia ABAJO Reduzca el recorrido hacia abajo girando el tornillo de ajuste en sentido horario Las luces no se apagan cuando la puerta se abre e El sistema de apertura de la puerta de la cochera cuenta con una funci n de seguridad de luz Esta funci n activa la luz cuando el haz del sensor est obstruido Consulte la secci n Operaci n C mo usar la unidad de control de puerta funci n Luz 33 T Bot n Aprender lA LED de diagn stico Sensor de seguridad de reversa Sensor de seguirdad de reversa sensor Sensor de seguirdad de reversa sensor emisor Luz indicadora mbar recepto Luz indicadora verde Sensor de seguridad de reversa Tabla de Diagnostico Circuito abierto de los sensores de seguridad cable cortado o desconectado O Cable en cortocircuito o conexi n invertida en cables negro blanco en sensores de seguridad 3 DESTELLOS Cortocircui
30. la manija de liberaci n de emergencia a menos que la entrada a la cochera est libre de obstrucciones y no haya ninguna persona presente e NUNCA use la manija para tirar de la puerta para abrirla o cerrarla Si el nudo de la cuerda se suelta usted podr a caerse C MO DESCONECTAR EL TROLE La puerta debe estar completamente cerrada si es posible Tire de la manija de liberaci n de emergencia de manera que el brazo de liberaci n del trole quede en una posici n vertical y levante la puerta manualmente La funci n de seguro evita que el trole se vuelva a conectar autom ticamente y la puerta pueda subirse y bajarse manualmente con la frecuencia que sea necesaria Brazo de liberaci n del trole en posici n de desconex on manual Posici n con el seguro desconexi n manual COMO RECONECTAR EL TROLE Tire de la manija de liberaci n de emergencia hacia el abridor en un ngulo que el brazo de liberaci n del trole quede Trole Brazo de liberaci n horizontal El trole se del trole reconecta en la siguiente Y operaci n HACIA ARRIBA o Manija de SED desconexion de emergencia Tirar a un angulo de 45 HACIA ABAJO ya sea manual o mediante el uso del control de la puerta o del control remoto Para reconectar MANTENIMIENTO DE SU ABRIDOR DE PUERTA DE COCHERA AJUSTES DE L MITE Y FUERZA Las condiciones climatol gicas pueden ocasionar cambios menores en la op
31. la tuerca de mariposa e Afloje la tuerca de mariposa del sensor receptor del rayo y reajuste hasta que reciba el rayo del sensor emisor Una vez que la luz verde brille permanentemente apriete la tuerca de mariposa 21 A ADVERTENCIA Para evitar la posibilidad de una LESI N GRAVE O INCLUSO LA MUERTE por electrocuci n o incendio e Aseg rese de que el abre puertas no est conectado a la energ a el ctrica y desconecte la alimentaci n el ctrica al circuito ANTES de quitar la cubierta para establecer la conexi n del cableado permanente e Tanto la instalaci n como el cableado de la puerta de garaje DEBEN cumplir con todos los c digos locales el ctricos y de construcci n e NUNCA use una extensi n ni un adaptador de dos hilos tampoco modifique la clavija para poder enchufarla Aseg rese de que el abre puertas est puesto a tierra CONEXI N PERMANENTE Terminal de puesta a tierra Tornillo verde de puesta a tierra Cable de puesta a tierra DIAGN STICO DE FALLAS CON RESPECTO A LOS SENSORES DEL SISTEMA DE REVERSA DE SEGURIDAD 1 Si la luz verde del sensor que emite el rayo no permanece encendida despu s de la instalaci n verifique lo siguiente e El suministro de corriente el ctrica al abridor e Que haya un corto circuito en alguno de los cables ya sea el banco o el blanco y negro Esto ocurre frecuentemente donde hay alguna grapa Alg n error en la conexi n de los cables de los sens
32. or loose clothing while INSTRUCTIONS installing or servicing opener They could be caught in Install garage door opener only on properly balanced and garage door or opener mechanisms lubricated garage door An improperly balanced door may Install wall mounted garage door control not reverse when required and could result in SEVERE e within sight of the garage door a a nab PE e out of reach of children at minimum height of 5 1 5 m repairs to cables spring assemblies and other hardware MUST be made by a trained door systems technician away om Al moning parts bi the dunt BEFORE installing opener Disable ALL locks and remove all ropes connected to garage door BEFORE installing opener to avoid entanglement de on inside of garage door Install garage door opener 7 2 13 m or more above floor _Upon completion of installation test safety reversal Mount emergency release handle 6 1 83 m above floor system Door MUST reverse on contact with a 1 1 2 NEVER connect garage door opener to power source until 3 8 cm high object or a 2x4 laid flat on the floor instructed to do so Place entrapment warning label on wall next to garage door control Place manual release safety reverse test label in plain view INSTALLATION STEP 1 Unfinished Ceilin Determine the Header Bracket i Location 4 amp WARNING To prevent possible SERIOUS INJURY or DEATH e Header bracket MUST be RIGIDLY fastened to structural
33. segundos La luz del bot n va a parpadear n mientras est activado el seguro Para desactivar la funci n oprima y mantenga oprimido el bot n del seguro por dos segundos La luz del bot n dejar de parpadear La funci n del seguro tambi n se apaga siempre que el bot n aprender del panel del motor est activado Funci n adicional cuando se usa con el control remoto manual de tres funciones Para controlar las luces del abridor Adem s de la operaci n de la puerta tambi n puede programar el control remoto para el funcionamiento de las luces 1 Con la puerta cerrada oprima y mantenga oprimido un bot n peque o del control remoto que desee usar para el control de la luz Oprima y mantenga oprimido el bot n de Luz del control de la puerta Mientras mantiene oprimido el bot n de Luz oprima y mantenga oprimido el bot n del seguro Lock del control de la puerta Despu s de que las luces del abridor se enciendan brevemente suelte todos los botones 31 C mo abrir la puerta manualmente 44 ADVERTENCIA Para evitar la posibilidad de una LESI N GRAVE o INCLUSO LA MUERTE si la puerta de la cochera se cae e De ser posible use la manija de liberaci n de emergencia para soltar el trole SOLO cuando la puerta de la cochera est CERRADA Si los resortes est n d biles o rotos o bien si la puerta est desbalanceada la puerta abierta podr a caerse r pida y o inesperadamente e NUNCA use
34. seguridad no se ha instalado debidamente las personas y los ni os peque os en particular podr an sufrir LESIONES GRAVES O INCLUSO LA MUERTE cuando se cierre la puerta del garaje e El ajuste incorrecto de los l mites del recorrido de la puerta del garaje habr de interferir con la operaci n adecuada del sistema de auto reversa de seguridad e Si se ajusta uno de los controles l mites de la fuerza o del recorrido es posible que sea necesario ajustar tambi n el otro control e Despu s de llevar a cabo cualquier ajuste SE DEBE probar el sistema de auto reversa de seguridad La puerta DEBE retroceder al entrar en contacto con un objeto de 3 8 cm 1 1 2 de pulg de altura o un tabl n de madera de 2x4 pulg acostado en el piso PRECAUCI N Para evitar que los veh culos sufran da os aseg rese de que cuando la puerta est completamente abierta quede suficiente espacio 27 Tornillos para el ajuste del l mite del recorrido Panel del lado izquierdo AS CALCOMAN A DE AJUSTES Si la puerta retrocede al cerrar y no hay ninguna interferencia visible en el ciclo del recorrido Si la luces del abridor parpadean esto significa que los sensores del sistema de retroceso de seguridad no est n instalados no est n alineados correctamente o hay alguna obstrucci n Vea la secci n de Diagn stico de fallas en la p gina 21 Pruebe la puerta para veri
35. subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation HAVING A PROBLEM N pa 1 My door will not close and the light bulbs blink on my motor unit The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction e Verify the safety sensors are properly installed aligned and free of any obstructions Refer to Installation Step 4 Install The Protector System e Check diagnostic LED for flashes on the motor unit then refer to the Diagnostic Chart on the following page Bell Wire N lt 1 Ly l DDD EEE pte een eo nn on nnn nee eee I A Diagnostic 2 My remotes will not activate the door LED e Verify your Premium door control is not blinking If it is blinking deactivate the Lock Mode following the instructions for Using the Premium Control Console e Reprogram remotes following the programming instructions Refer to Programming ieee i i Receiving Eye Safety Reversi e If remote will still not activate your door check elie cad Sensor Green indicator Light diagnostic LED for flashes on motor unit then refer to Diagnostic Ch
36. the bracket on the vertical centerline with the bottom edge of the bracket on the horizontal line as shown with the arrow pointing toward the ceiling e Mark the vertical set of bracket holes Drill 3 16 pilot holes and fasten the bracket securely to a structural support with the hardware provided HARDWARE SHOWN ACTUAL SIZE Lag Screw 5 16 9x1 5 8 CEILING HEADER BRACKET INSTALLATION e Extend the vertical centerline onto the ceiling as shown e Center the bracket on the vertical mark no more than 6 15 cm from the wall Make sure the arrow is pointing toward the wall The bracket can be mounted flush against the ceiling when clearance is minimal e Mark the side holes Drill 3 16 pilot holes and fasten bracket securely to a structural support with the hardware provided Ceiling Mounting Holes CEILING MOUNT ONLY The nail hole is for positioning only You must use lag screw to mount the header bracket Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket Optional Vv Wall Mounting Holes Vertical Centerline of Garage Door Header Wall Lag Screws 5 16 9x1 5 8 2x4 Structural Support 1 1 Horizontal Line gt Garage 1 Door Highest Point of i Garage Door Travel Vertical Centerline of Garage Door gAn Finished Ceiling ad ete Vertical r pd ae 2 2 Header Cente
37. the door is closing Safety Reversing Sensor 6 15 cm max above floor Invisible Light Beam Protection Area Facing the door from inside the garage Safety Reversing Sensor 6 15 cm max above floor INSTALLING THE BRACKETS Be sure power to the opener is disconnected Install and align the brackets so the sensors will face each other across the garage door with the beam no higher than 6 15 cm above the floor They may be installed in one of three ways as follows Garage door track installation preferred Slip the curved arms over the rounded edge of each door track with the curved arms facing the door Snap into place against the side of the track It should lie flush with the lip hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 amp 3 Place the bracket against the wall with curved arms facing the door Be sure there is enough clearance for the sensor beam to be unobstructed If additional depth is needed an extension bracket see Accessories or wood blocks can be used Use bracket mounting holes as a template to locate and drill 2 3 16 diameter pilot holes on the wall at each side of the door no higher tha
38. there is any binding or sticking If your door binds sticks or is out of balance call a trained door systems technician Sectional Door One Piece Door Ss j Carpenter s Level Optional Tape Measure 3 16 5 16 and 5 32 Drill Bits 4 amp WARNING To prevent possible SERIOUS INJURY or DEATH e ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An unbalanced garage door may not reverse when required e NEVER try to loosen move or adjust garage door door springs cables pulleys brackets or their hardware all of which are under EXTREME tension e Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement CAUTION To prevent damage to garage door and opener e ALWAYS disable locks BEFORE installing and operating the opener e ONLY operate garage door opener at 120V 60 Hz to avoid malfunction and damage Tools needed During assembly installation and adjustment of the opener instructions will call for hand tools as illustrated below Ponci 0000 E H A lt Hack Saw gt gt Wire Cutters gt Pliers ES Claw Hammer A AO E 20 Screwdriv r Adjustable End Wrench Planning Identify the type and height of your garage door Survey your garage area to see if any of the condi
39. 1 to provide rigid support On finished ceilings Figure 2 and Figure 3 attach a sturdy metal bracket to structural supports before installing the opener This bracket and fastening hardware are not provided 1 Measure the distance from each side of the motor unit to the structural support Cut both pieces of the hanging bracket to required lengths Drill 3 16 pilot holes in the structural supports Attach one end of each bracket to a support with 5 16 18x1 7 8 lag screws Fasten the opener to the hanging brackets with 5 16 18x7 8 hex bolts lock washers and nuts Check to make sure the rail is centered over the door or in line with the header bracket if the bracket is not centered above the door Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket NOTE DO NOT connect power to opener at this time 2 7 HARDWARE SHOWN ACTUAL SIZE Lag Screw 5 16 9x1 5 8 mm Hex Bolt 5 16 18x7 8 Nut 5 16 18 Lock Washer 5 16 4 amp WARNING To avoid possible SERIOUS INJURY from a falling garage door opener fasten it SECURELY to structural supports of the garage Concrete anchors MUST be used if installing any brackets into masonry Figure 1 Structural Measure L Distance z 9 Lag Screws 5 16 18x1 7 8 Bolt 5 16 18x7 8 Lock Washer 5 16 Nut 5 16 18 Figure 2 oe Bracket Not Provided _ 7 N
40. 9x1 5 8 2 Hex Bolt Insulated 5 16 18x7 8 4 Lock Washer 5 16 6 Staples 30 SI00000000000 po Lag Screw 5 16 18x1 7 8 2 Screw 6ABx1 1 4 2 Screw 6 32x1 Qe Drywall Anchors 2 Carriage Bolt 5 16 18x2 1 2 2 Spacer Clevis oe 5 16 x1 Clevis Pin Clevis Pin 5 16 x2 3 4 1 5 16 x1 1 4 1 ASSEMBLY STEP 1 CAUTION Assemble the Rail To prevent INJURY from pinching keep hands and fingers away from the joints while assembling the rail To avoid installation difficulties do not run the garage door opener until instructed to do so 1 Open the rail carton and remove the contents onto a level work surface Keep it clean and free of debris HARDWARE SHOWN ACTUAL SIZE while you are working 2 Identify the rail sections and orient the sections on a flat surface as shown The back rail has a black gear on one end The header rail has a black plastic rack inside the rail on the screw The remaining section is the Hex Bolt 1 4 20x7 16 center rail NOTE Use caution when handling the center rail section The screw can slip out if the section is tipped up too far Remove Cardboard Packing ly Rail Assemb Q Ye gt Q Remove Cardboard Packing b Sprocket Coupling Remove Cardboard Packing Rail Assembly Carton Hex Bolts 1 4 20x7 16 Hex Bolts 1 4 20x7 16 Hex Bolts 1 4 20x7 16 Center Rail Hex Bolts 1 4 20x7 16 Assemble the Rail conti
41. CIA ABAJO cerrar e Sujete la puerta manualmente agarr ndola por la parte inferior y det ngala m s o menos a la mitad del recorrido HACIA ABAJO cerrar la puerta deber retroceder Si la puerta retrocede a la mitad del recorrido esto no garantiza que la puerta retroceder al toparse con una obstrucci n de 3 8 cm 1 1 2 de pulg Dirijase al Paso 3 de la secci n de Ajustes en la p gina 29 Si es dif cil sostener la puerta o bien si la puerta no retrocede DISMINUYA la fuerza del movimiento HACIA ABAJO cerrar con el control de ajuste d ndole vuelta hacia la izquierda Haga peque os ajustes hasta que la puerta retroceda correctamente Despu s de llevar a cabo un ajuste haga funcionar el abridor durante un ciclo completo del recorrido Si la puerta retrocede autom ticamente en la trayectoria hacia abajo cerrar y la luces del abridor no est n parpadeando AUMENTE la fuerza de la trayectoria HACIA ABAJO cerrar con el control de ajuste d ndole vuelta hacia la derecha Haga peque os ajustes hasta que la puerta complete un ciclo de cerrado Despu s de llevar a cabo el ajuste haga funcionar el abridor durante un ciclo completo del recorrido No aumente la fuerza m s del m nimo necesario para cerrar la puerta 2 Pruebe la fuerza del recorrido HACIA ARRIBA abrir e Sujete la puerta manualmente agarr ndola por la parte inferior y det ngala m s o menos a la mitad del recorrido HACIA ARRIBA abrir la puerta deber d
42. ERTE por electrocuci n e ANTES de instalar el control de la puerta cerci rese de que la energ a el ctrica no est conectada e Conecte el control SOLO a cables de bajo voltaje de 24 VOLTIOS Para evitar la posibilidad de una LESI N GRAVE e INCLUSO LA MUERTE cuando la puerta de la cochera se est cerrando e Instale el control de la puerta de manera que quede a la vista desde la puerta de la cochera fuera del alcance de los ni os a una altura m nima de 1 5 m 5 pies y alejado de las partes m viles de la puerta e NUNCA permita que los ni os hagan funcionar o jueguen con los botones de control de la puerta ni con los transmisores de control remoto e Haga funcionar la puerta SOLO si la puede ver claramente si la puerta est debidamente ajustada y si no no hay ninguna obstrucci n en su recorrido SIEMPRE tenga a la vista la puerta de la cochera hasta que est completamente cerrada NUNCA permita que alguien se atraviese en el recorrido de la puerta de la cochera cuando se est cerrando Conexiones para la Unidad de Control Exterior Conecte a las terminales de conexi n r pida el blanco al blanco blanco rojo al rojo ESTAS PIEZAS SE MUESTRAN EN SUTAMA O REAL IO Tornillo para la consola de control de 6AB por 1 1 4 de pulg instalaci n est ndar Tornillo para la consola de control de 6 32 por 1 pulg instalaci n precableada Grapas con aislamiento Taquetes para muro falso
43. Elemento wm ptico MONTAJE PARED LADO DERECHO M nsula de extensi n v ase la secci n Accesorios Suministrado con m nsula de extensi n o Tng gt Y QU M nsula del sensor Elemento ptico MONTAJE EN PISO LADO DERECHO para concreto no incluidos Fijar con tarugos Luz indicadora del sensor MONTAJE Y CABLEADO DE LOS SENSORES DEL SISTEMA DE RETROCESO DE SEGURIDAD e Deslice la cabeza de un perno de coche de 14 20x1 2 de pulgada dentro de la ranura de los sensores Use tuercas de mariposa para sujetar los sensores a las m nsulas con las lentes de cada sensor frente a frente a ambos lados de la puerta Cerci rese de que la extensi n de la m nsula no obstruya las lentes Figura 5 e Apriete las tuercas de mariposa a mano Ruta recomendada para el cableado 1 Usando grapas con aislamiento corra los cables de los dos sensores hasta el riel del cabezal de la puerta Figura 6 2 Fije los cables en la parte superior de los rieles por medio de las presillas de cables NOTA Si su puerta de acceso est cerca de la puerta del garaje puede escoger instalar el control de la puerta en este momento y fijar el cable de control de la puerta a lo largo del riel con los cables del sensor Si opta por esta alternativa siga ahora las instrucciones 1 a 3 de la p gina 20 Figura 6 Cable del sensor Presilla de cables ee a Sensor de reversa de seguridad
44. NCIA Para evitar la posibilidad de una LESI N GRAVE o INCLUSO LA MUERTE si la puerta del garaje se cae e De ser posible use la manija de emergencia para soltar el trole S LO cuando la puerta del garaje est CERRADA Si los resortes est n d biles o rotos o bien si la puerta est desequilibrada la puerta podr a caerse r pida y o inesperadamente mientras se encuentra abierta e NUNCA use la manija de emergencia a menos que la entrada del garaje est libre de obstrucciones y no haya ninguna persona presente e NUNCA use la manija para abrir o cerrar la puerta Si el nudo de la cuerda se suelta usted podr a caerse Brazo de desenganche del trole Manija de desenganche de emergencia INSTALACION PASO 12 Fije la m nsula de la puerta Siga las instrucciones que correspondan al tipo de puerta de cochera que usted tenga como se muestra en la ilustraci n o en la p gina siguiente Si usa un puntal horizontal ste debe ser lo suficientemente largo para sujetarlo a dos soportes verticales Si usa un puntal vertical ste debe ser de la altura del panel superior La ilustraci n muestra una pieza de hierro en ngulo como puntal horizontal Para el puntal vertical se deben usar dos piezas de hierro en ngulo con objeto de crear un soporte en U Figura 1 La mejor soluci n es ponerse en contacto con la compa a fabricante de la puerta de su cochera e informarse acerca de los juegos de refuerzo
45. Orificio superior de montaje UNIDAD DE CONTROL PREMIUM largo del tope del riel Vea la p gina 17 Bot n con gt Tornillos P apis A terminales 4 Pase todos los cables a trav s del orificio de la parte superior i ae de la unidad del motor por encima del bloque de terminales que ee ncuentra en el panel terior Figura 3 se encuentra en el panel posterior Figura 3 VISTA ROSTERIGA 5 Pele 11 mm 7 16 de pulg de aislaci n de cada conjunto de Fi 4 Fi ae i cables Inserte el cable de control de la puerta dentro de los igura igura 4 INSTALACION PRECABLEADA conectores de conexi n r pida por color cable blanco a blanco ao rad cable blanco rojo a rojo Para volver a ponerla su primero inserte Para quitarla Separe los cables blancos y blanco negro suficientemente para las lengiietas doble conectar a los terminales de conexi n r pida del abridor Tuerza superiores _ kg aqu juntos los cables del mismo color Insertar los cables dentro de los orificios de conexi n r pida blanco a blanco y blanco negro a gris NOTA AI conectar controles m ltiples de la puerta al abre puertas tuerza juntos los cables del mismo color Inserte los cables en los orificios de conexi n r pida blanco a blanco y rojo blanco a rojo 6 Use tachuelas o grapas para sujetar permanentemente la calcoman a de advertencia sobre el riesgo de quedar atrapado esta calcoman a debe estar en la p
46. Owner s Manual Manual Del Propietario CRAFTSMAN 3 4 HP 315 mw GARAGE DOOR OPENER ABRIDOR DE PUERTA DE COCHERA DE 315 mu For Residential Use Only S lo para uso residencial Model Modelo 139 53925DS Read and follow all safety rules and operating instructions before first use of this product Fasten the manual near the garage door after installation Periodic checks of the opener are required to ensure safe operation Us TONWdS4 HSITMONI Leer y seguir todas las reglas de seguridad y las instrucciones de operaci n antes de usar este producto por primera vez Guardar este manual cerca de la puerta de la cochera Se deben realizar revisiones peri dicas del abridor de puertas para asegurar su operaci n segura Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com craftsman TABLE OF CONTENTS Introduction 2 7 Safety symbol and signal word revieW 2 Preparing your garage door 2 0000 3 Tools needed oooocccco 3 Planning errores nee eee E eRe eee 4 5 Carton inventory sasaaa 6 Hardware inventory aaaea 7 Assembly 8 11 Assemble the rail 2 000 000 eee eee 8 9 Fasten the rail to the motor unit and install the trolley 0 2 0 0 cee eee ee 10 Attach the rail bracketS oooooooooooo o 11 Installation 11 26 Installation safety instructions 11 Determine the header bracket location
47. PORTANT SAFETY CHECK Test the Safety Reverse System after Each adjustment of door arm length limits or force controls e Any repair to or adjustment of the garage door including springs and hardware e Any repair to or buckling of the garage floor e Any repair to or adjustment of the opener ADJUSTMENT STEP 4 Test The Protector System e Press the remote control push button to open the door e Place the opener carton in the path of the door e Press the remote control push button to close the door The door will not move more than an inch 2 5 cm and the opener lights will flash The garage door opener will not close from a remote if the indicator light in either sensor is off alerting you to the fact that the sensor is misaligned or obstructed If the opener closes the door when the safety reversing sensor is obstructed and the sensors are no more than 6 15 cm above the floor call for a trained door systems technician 4 amp WARNING Without a properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door e Safety reversal system MUST be tested every month e If one control force or travel limits is adjusted the other control may also need adjustment e After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with 1 1 2 high 3 8 cm object or 2x4 laid flat on the f
48. Quite el cart n de protecci n M nsulas del cabezal y del riel Q Quite el cart n de protecci n Quite el cart n de protecci n Caja del riel Perno hexagonal de de e de pulg Perno hexagonal de 1 4 20x7 16 de pulg Montaje el riel contin a 3 Sujete los tirones de soporte del carril al carril trasero Introduzca sin apretar pernos hexagonales de 1 4 20x7 16 en los agujeros alineados del carril de extremo y el tirante de soporte del carril Figura 1 No apriete con los dedos Extienda el tornillo de impulsi n unos cuantos cent metros desde el carril central y deslice el manguito sobre el mu n largo Figura 2 Enclave el mu n largo y corto del centro y los carriles traseros Deslice el manguito sobre la conexi n del mu n Figura 3 Coloque la presilla en C sobre el eje del mu n largo carril central para asegurarse de que el manguito no se deslice Figura 4 Deslice el carril central de modo que los agujeros del carril central y del tirante del carril est n alineados Figura 5 Fije con pernos 8 Apriete todos los pernos hexagonales Repita los pasos 3 8 para la secci n de encabezado Figura 1 Tirante de soporte del carril Tirante de soporte del carril Figura 2 Manguito de metal Mu n largo Carril central Figura 3 Mu n corto Mu n largo Tirant
49. R Spring Access Door Do you have an access door in addition to the garage door If not Model 53702 Emergency Key Release is required See Accessories page Look at the garage door where it meets the floor Any gap between the floor and the bottom of the door must not exceed 1 4 6 mm Otherwise the safety reversal system may not work properly See Adjustment Step 3 Floor or door should be repaired SECTIONAL DOOR INSTALLATIONS Do you have a steel aluminum fiberglass or glass panel door If so horizontal and vertical reinforcement is required Installation Step 12 The opener should be installed above the center of the door If there is a torsion spring or center bearing plate in the way of the header bracket it may be installed within 4 feet 1 2 m to the left or right of the door center See Installation Steps 1 and 12 e If your door is more than 7 feet 2 13 m high see rail extension kits listed on Accessories page FINISHED CEILING Support bracket amp fastening hardware is required See page 19 Boore Motor unit CLOSED POSITION Rail Assembly Header Bracket ail Bracket Straight Door Spring Emergency Release Rope amp Handle Planning Continued ONE PIECE DOOR INSTALLATIONS e Generally a one piece door does not require reinforcement If your door is lightweight refer to the information
50. Reemplace UNICAMENTE con bater as planas 3V2032 e NO recargue desarme caliente por encima de 212 F 100 C o incinere La bater a de litio puede durar hasta 5 a os Para cambiar la bater a use el broche del visera o un destornillador para abrir la tapa tal como se indica en la ilustraci n Coloque la bater a con el lado positivo hacia arriba Elimine las bater as usadas en forma adecuada Abra este extremo primero para evitar que la caja se agriete Reemplace las pilas solamente por pilas de bot n 3V2032 AVISO Para cumplir con las reglas de la FCC y o de Canad IC ajustes o modificaciones de este receptor y o emisor est n prohibidos excepto por el cambio de la graduaci n del c digo o el reemplazo de la pila NO HAY OTRAS PIEZAS REPARABLES DEL USUARIO Se ha probado para cumplir con las normas de la FCC para USO DEL HOGAR O DE LA OFICINA La operaci n est sujeta a las dos condiciones siguientes 1 este dispositivo no puede causar interferencia perjudicial y 2 este dispositivo debe aceptar cualquier interferencia recibida incluyendo la interferencia que puede causar una operaci n no deseable SI TIENE ALGUN PROBLEMA 1 La puerta no cierra y las luces de la unidad del motor parpadean El sensor del sistema de retroceso de seguridad debe estar instalado y alineado correctamente para que el sistema de apertura de la puerta de la cochera se mueva en sentido descendente
51. a inclusive el fracaso para instalar ajustar y operar este abridor de puerta de cochera seg n instrucciones contenidas en el manual Este garant a limitada tambi n no cubre ning n problema causado por interferencia L mite de responsabilidad legal El vendedor no sera responsible de la p rdida ni el da o a la propiedad ni ninguna p rdida ni el gasto casuals ni consecuentes del da o de la propiedad debido directamenta ni indirectamenta al uso de este producto Algunos estados no permiten la exclusion ni la limitaci n de da os casuals as qe el encima de la limitaci n ni la exclusi n no puede aplicar a usted Denegacion de garant as implicitas Menos el motor todas garant as impl citas para este producto inclusive pero no limitado a ninguna garant a impl cita de merchantability y salud para un prop sito particular se limitan en la duraci n al d a 91 por de 3 a os limit la garanti a el conjunto del per odo adelante arrriba Todas garant as impl citas con respecto al motor se limitan en la duraci n al d a 91 aunque de 7 a os de la garant a adelante arriba Algunos estados no permiten las limitaciones en cuean laraga una garant a impl cita duran asi que el encima de limitaciones no puede aplicar a usted Servicio de la garant a esta disponible llamando 1 800 4 MY HOME Esta garanti aplica solo mientras este producto est en el uso en los Estados Unidos Esta garant a le da derechos legales espec ficos y useted puede te
52. ale el tomacorriente adecuado CORRECTO INCORRECTO Si la reglamentaci n municipal exige que su abre puertas tenga cableado permanente siga los siguientes pasos Para efectuar una conexi n permanente usando la entrada superior de 7 8 de pulg en la parte superior del motor e Quite los tornillos de la tapa del motor y desmonte la tapa Quite el cord n de 3 patas Conecte el cable negro de l nea al tornillo del terminal de bronce el cable blanco neutro al tornillo del terminal plateado y el cable de tierra al tornillo verde El abre puertas debe tener conexi n a tierra Vuelva a colocar la tapa Para evitar problemas con la instalaci n no poner el abre puertas en funcionamiento INSTALACI N PASO 9 Termine la instalaci n del sensor del sistema de reversa de seguridad C MO ALINEAR LOS SENSORES DE SEGURIDAD e Conecte el abridor las luces del sensor emisor y del sensor receptor se deben de encender y permanecer encendidas si todas las conexiones del cableado y la alineaci n se han hecho correctamente La luz mbar del sensor que emite el rayo se encender aunque est obstruido o fuera de alineaci n pero si la luz verde del sensor receptor del rayo est apagada parpadea o se ve baja y no hay ninguna obstrucci n en el recorrido del rayo de luz invisible ser necesario alinearlos e Afloje la tuerca de mariposa del sensor emisor y reajuste el sensor Apunte directamente al otro sensor y apriete
53. allation Step 4 1 Working on a level surface align the rail assembly with the motor unit as shown 2 Slip the coupling over the rail sprocket 3 Slide the rail through the motor unit bracket until the coupling fits securely over the motor unit sprocket 4 Align the four bolt holes in the rail with those in the motor unit bracket Insert four 1 4 20x7 16 hex bolts Tighten securely with a 3 8 socket wrench 5 Disengage trolley by turning the release arm down Slide trolley onto and along the bottom of the rail until it aligns with the rack Turn release arm up This will join the rack and the trolley Motor Unit Bracket Motor Unit Sprocket Hex Bolts 1 4 20x7 16 Coupling Rail Sprocket Rail Assembly Foam Packaging To the motor unit Hex Bolts 1 4 20x7 16 ASSEMBLY STEP 3 Rail Brackets Attach the Rail Brackets e Align rail brackets to end of rail assembly as shown e Insert two 1 4 20x7 16 hex bolts Tighten securely with a 3 8 socket ay Hex Bolt You have now finished assembling your garage door NE opener Please read the following warnings before proceeding to the installation section Hex Bolt 1 4 20x7 16 HARDWARE SHOWN ACTUAL SIZE Hex Bolt 1 4 20x7 16 INSTALLATION IMPORTANT INSTALLATION INSTRUCTIONS A 44 WARNING To reduce the risk of SEVERE INJURY or DEATH READ AND FOLLOW ALL INSTALLATION WARNINGS AND 8 NEVER wear watches rings
54. ano sobre el piso INSTALACION PASO 1 sues Determine donde va a instalar la m nsula terminaci n del cabezal 44 ADVERTENCIA Para evitar una posible LESI N GRAVE O INCLUSO LA MUERTE La m nsula del cabezal DEBE quedar R GIDAMENTE sujeta al L nea vertical del soporte estructrual en la pared delantera o en el cielo raaso de no canta de la puenta e ser as es posible que la puerta del garaje no retroceda cuando se iia requiera NO instale la m nsula del cabezal en muros falsos Se DEBEN usar sujetadores para concreto si el montaje de la m nsula del cabezal o del pedazo de madera de 3 8 cm 2x4 pulg Wr MONTAJE OPCIONAL DE MENSULA DE CABEZAL EL TECHO Pared de cabecera Soportes de la estructurales se hace en mamposter a NUNCA trate de aflojar mover ni ajustar la puerta del garaje los resortes los cables las pleas las m nsulas ni la perner a pues todas estas piezas est n bajo una tensi n EXTREMA AA j SIEMPRE llame a un t cnico especializado en sistemas de puertas 0 Nivel si la puerta del garaje se atasca atora o si esta desquilibrada Una N opcional puerta de garaje que no est equilibrada puede no retroceder S5 cuando se requiera G Los procedimientos de instalaci n var an seg n el tipo de puerta de garaje Siga las instrucciones que corresponden a su tipo de puerta Bs 1 Con la puerta cerrada localizar y m
55. ara usarse cuando se instala el abridor en una cochera con poca tolerancia altura as lo desee 41A5281 M nsulas de extensi n S lo est n disponibles a trav s de Refacciones y Servicio Sears 139 53749 Control a luz enchutable o El Permite al due o de la casa encender una SS i Opcionales Para la instalaci n del sensor de l mpara la televisi n u otro aparato seguridad en la pared o en el piso dom stico con el control remoto desde el coche la cama o dondequiera que se encuentre en la casa GARANT A Garant a limitada de abridor de puerta de cochera Craftsman Garant a completa en casa de 90 d as por producto Para 90 d as a partir de la fecha de compra este producto se reparar sin cargo si se determina que est defectuoso en su material o manufactura Garant a limitada adicional por las piezas Desde el d a 91 hasta 3 a os despu s de la fecha de compra las piezas del reemplazo para alguna parte defectuosa en este producto se proporcionar n libre de la carga Usted paga por el trabajo Garant a limitada adicional por la vida del motor Desde el dia 91 hasta 7 a os si el motor en este producto es defectuoso un motor del reemplazo se proporcionar libre la carga Usted paga por el trabajo Restriccion de la garant a Este garant a limitada del abridor de puerta de cochera de Craftsman no cubre las bombillas ni la reparaci n despiden necesario a causa del abuso de operario ni negligenci
56. arcar la linea vertical del of centro de la misma 2 Extender la marca de la linea de centro hasta la pared sobre la puerta Se puede fijar el soporte del cabezal dentro de una distancia de 1 22 m 4 pies a la izquierda o a la derecha del centro de la puerta solamente si estorba un resorte Sx AA de torsi n o la placa central de soporte Tambi n se puede Punto m s Gu a fijar al cielo raso ver p gina 13 si el espacio disponible alto de recorrido fuera insuficiente Asimismo se puede instalar en forma invertida sobre la pared si fuese necesario Esto le A otorgar aproximadamente 1 cm 1 2 de pulg m s de espacio Hd Si necesita instalar la m nsula del cabezal en un tirante de madera de 3 8 cm 2x4 pulg ya sea en la pared o en el cielo rd raso fije el tirante firmemente a soportes estructurales usando tirafondos tal como se indica aqui y en la pagina 13 3 Abra la puerta hasta el punto m s alto de su recorrido tal como se muestra Marque una l nea horizontal en la pared a las siguientes distancias sobre el punto m s alto del recorrido de la puerta e A 7 5 cm 3 pulg sobre el punto m s alto de una puerta seccional o puerta de una sola pieza con gu as e A 20 cm 8 pulg sobre el punto m s alto de una de una Pared de cabecera 20 om 8 pulg sola pieza sin gu as 20 cm 8 pulg n o A esta altura el extremo superior de la puerta tendr LS suficiente espacio para su recorrido Punto ma
57. ard N 4 Release buttons when the motor unit lights blink It has learned the code If N light bulbs are not installed two clicks gt will be heard To Erase All Codes From Motor Unit 3 Function Remotes Memor y If provided with your garage door opener the large button To deactivate any unwanted remote first erase all codes is factory programmed to operate it Additional buttons on any Security e 3 Function remote or compact remote can be programmed to operate other Securityke garage door openers Press and hold the learn button on motor unit until the learn indicator light goes out approximately 6 seconds All previous codes are now erased Reprogram each remote or keyless entry you wish to use To Add Reprogram or Change a Keyless Entry PIN NOTE Your new Keyless Entry must be programmed to operate your garage door opener USING THE PREMIUM CONTROL CONSOLE USING THE LEARN BUTTON k Press and release the learn button on motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds enter a four digit personal identification number PIN of your choice on the keypad Then press and hold the ENTER button 3 Release the button when the motor unit lights blink It has learned the code If light bulbs are
58. ared y cerca del control de la puerta La calcoman a de advertencia de la prueba de reversa de seguridad y liberaci n manual debe colocarse en un punto prominente del interior de la puerta de la cochera NOTA NO conecte el abridor a la energ a el ctrica ni lo haga funcionar en este momento El trole har el recorrido hasta llegar ne ws pulg Roio Blanco Gris a la posici n completamente abierta pero no regresar a la posici n cerrada hasta que el rayo del sensor est conectado y Pele el cable 11 mm 7 16 de pulg alineado debidamente 20 Cable de campana de 24 voltios de dos conductores Figura 3 Pele 11 mm 7 16 de pulg Insertar los cales a trav s de la abertura en el tope de la unidad del motor sobre el bloque terminal y a continuaci n dentro de los terminales de conexi n r pida Para soltar o insertir el cable empuje la leng eta hacia dentro con la punta Conexiones del de un destornillador control de la puerta INSTALACION PASO 8 Requisitos para la instalaci n el ctrica Para evitar problemas con la instalaci n no opere el abre puertas hasta paso 9 abajo Para reducir el riesgo de electrocuci n el abre puertas de garaje viene con enchufe con pata de conexi n a tierra Este enchufe s lo se puede conectar a un tomacorriente con conexi n de puesta a tierra Si el enhcufe no entra en el tomacorriente de su instalaci n contrate un electricista profesional para que inst
59. art on the following page Safety Reversing Sensor 3 My door reverses for no apparent reason Repeat safety reverse test after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel e Manually check door for balance or any binding problems e Refer to Adjustment Step 2 Adjust the Force 4 My door reverses for no apparent reason after fully closing and touching the floor Repeat safety reverse test after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel e Refer to Adjustment Step 1 Adjust the UP and DOWN Travel Limits Decrease down travel by turning down limit adjustment screw clockwise 5 My lights will not turn off when door is open e The garage door opener is equipped with a security light feature This feature activates the light on when the safety sensor beam has been obstructed Refer to Operation section Using the Wall Mounted Door Control Light Feature 33 W oH awt gt bli ls inv ZPD wy D Diagnostics Located On Motor Unit B perenne
60. ce beyond minimum amount required to close garage door e NEVER use force adjustments to compensate for a binding or sticking garage door e If one control force or travel limits is adjusted the other control may also need adjustment e After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with 1 1 2 high 3 8 cm object or 2x4 laid flat on floor Force Adjustment Controls Back Panel ADJUSTMENT LABEL Open Force Close Force ADJUSTMENT STEP 3 Test the Safety Reversal System TEST e With the door fully open place a 1 1 2 3 8 cm board or a 2x4 laid flat on the floor centered under the garage door e Operate the door in the down direction The door must reverse on striking the obstruction ADJUST e If the door stops on the obstruction it is not traveling far enough in the down direction Increase the DOWN limit by turning the DOWN limit adjustment screw counterclockwise 1 4 turn NOTE On a sectional door make sure limit adjustments do not force the door arm beyond a straight up and down position See the illustration on page 25 Repeat the test When the door reverses on the 1 1 2 3 8 cm board remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IM
61. cerrar la puerta Oprima de nuevo para que la puerta retroceda en el ciclo de cierre o para detener la puerta cuando se est abriendo Bot n Iluminado Luz seguro Oprima el bot n de Luz para encender o apagar la luz del abridor Este bot n no controla las luces del abridor cuando la puerta est en movimiento Si usted enciende la luz y luego activa el abridor la luz permanecer encendida durante cuatro minutos y medio Oprima el bot n nuevamente para que la luz se apague antes El intervalo de 4 minutos y 1 2 puede cambiarse a 1 minuto y 1 2 2 minutos y 1 2 o 3 minutos y 1 2 como sigue Oprima y mantenga oprimido el bot n del seguro Lock hasta que la luz empiece a parpadear alrededor de 10 segundos Si parpadea una vez esto indica que el medidor de tiempo se ha fijado a un minuto y medio Repita el procedimiento y la luz parpadear dos veces lo que significa que el intervalo se ha fijado en 2 minutos y 1 2 Repita una vez m s si desea un intervalo de 3 minutos y 1 2 etc hasta un m ximo de 4 minutos y 1 2 en cuyo caso la luz parpadear cuatro veces Seguro Esta funci n est dise ada para evitar la operaci n de la puerta con los controles remotos manuales No obstante la puerta se puede abrir y cerrar con los siguientes accesorios el Control de la puerta el Interruptor de llave externo y la Entrada sin llave Para activar esta funci n oprima y mantenga oprimido el bot n del seguro Lock por dos
62. crews not provided Poor to securely fasten the 2x4 to structural supports as LH shown here and on page 13 Open your door to the highest point of travel as shown Ho Draw an intersecting horizontal line on the header wall above the high point Highest Point of Travel Highest Point of Travel w Sectional door with curved track One piece door with horizontal track e 3 7 5 cm above the high point for sectional door and one piece door with track e 8 20 cm above the high point for one piece door without track y 7 Header Wall This height will provide travel clearance for the top edge Header Wall Z 8 20 om of the door Ta 20 om botar Highest Point of Travel 1 Highest Point 1 Of Travel NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 13 for ceiling installation Jamb Hardware Pivot One piece door without track One piece door without track jamb hardware pivot hardware INSTALLATION STEP 2 Install the Header Bracket You can attach the header bracket either to the wall above the garage door or to the ceiling Follow the instructions which will work best for your particular requirements Do not install the header bracket over drywall If installing into masonry use concrete anchors not provided WALL HEADER BRACKET INSTALLATION e Center
63. ction breaks the light beam while the door is closing the door will stop and reverse to full open position and the opener lights will flash 10 times The units must be installed inside the garage so that the sending and receiving eyes face each other across the door no more than 6 15 cm above the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware 4 amp WARNING Be sure power is not connected to the garage door opener BEFORE installing the safety reversing sensor To prevent SERIOUS INJURY or DEATH from a closing garage door e Correctly connect and align the safety reversing sensor This required safety device MUST NOT be disabled e Install the safety reversing sensor so beam is NO HIGHER than 6 15 cm above garage floor If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface such as the wall framing Extension brackets see Accessories are available if needed If installing in masonry construction add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary The invisible light beam path must be unobstructed No part of the garage door or door tracks springs hinges rollers or other hardware may interrupt the beam while
64. da con la m nsula del cabezal seg n se indica en la ilustraci n Marque ya sea los orificios derecho e izquierdo o superior y inferior e Taladre los orificios piloto de 5 16 de pulg y sujete la m nsula con la torniller a que se incluye Si la puerta no tiene un marco exterior expuesto taladre dos orificios de 3 16 de pulg y sujete la m nsula a la parte superior de la puerta con tornillos de cabeza cuadrada de 5 16x1 1 2 de pulg no se incluyen z Tuerca de 5 16 18 NOTA La m nsula para la puerta puede ser instalada sobre la Arandela de 5 16 de pulg orilla superior de la puerta si es necesario para su instalaci n en particular Vea la ilustraci n de colocaci n opcional se alada con la l nea punteada Taladre dos orificios de 3 16 de pulg y sujete la m nsula a la parte superior de la puerta con tornillos Perno de coche de de cabeza cuadrada de 5 16x1 1 2 de pulgadas no se incluyen 5 16 18 por 2 1 2 de pulg ESTAS PIEZAS SE MUESTRAN EN SU TAMA O REAL a _ Pared delante Madera de 5x10 cm Cielo raso con acabado 2x4 pulg Si su puerta es de metal aluminio fibra de vidrio o con paneles de vidrio siempre son necesarios M nsula de refuerzos verticales y horizontales la puerta No se incluyen Colocaci n i opcional para la m nsula de la puerta 1 Linea central S Arandela m vertical de la de 5 16 de i j F pulgada 1 puerta de
65. de ajuste que aparece a continuaci n Cierre la puerta manualmente y suba el brazo de la puerta al trole El brazo de la puerta deber tocar el trole justo delante del orificio conector del brazo de la puerta Consulte la ilustraci n correspondiente al brazo de la puerta y al trole Ajuste de la puerta al abrirla Disminuya el l mite del en su posici n completamente cerrada Si el brazo queda recorrido HACIA ARRIBA detr s del orificio conector ajuste el l mite del recorrido de Ajuste el tornillo para ajustar el l mite del recorrido HACIA la puerta cada vuelta completa del tornillo equivale a 5 cm ARRIBA d ndole 4 vueltas hacia la izquierda 2 pulg de recorrido del trole Oprima el bot n de control de la puerta El trole deber ir 3 Conecte el brazo de la puerta al trole hasta la posici n completamente abierta e Cierre la puerta y sujete el brazo curvo al orificio conector Abra la puerta manualmente de manera que est paralela del trole con el ltimo pasador de chaveta Es posible que con el piso y suba el brazo de la puerta al trole El brazo de necesite levantar un poco la puerta manualmente para poder la puerta deber tocar el trole justo en la parte posterior del hacer esta conexi n orificio conector Consulte la ilustraci n correspondiente al e Asegure con un anillo sujetador brazo de la puerta y al trole en su posici n completamente abierta Si el brazo no se extiende lo suficiente ajuste el l mite
66. de coche de 5 16 18 por 2 1 2 de pulg e Marque y taladre dos orificios de 5 16 de pulg para los sujetadores a la derecha y a la izquierda Sujete la m nsula al refuerzo vertical si ste existe como se muestra en la Figura 1 Si el tipo de instalaci n de su cochera no requiere refuerzos verticales pero s necesita los orificios para los sujetadores de la m nsula taladre y f jelos como se muestra en la Figura 2 Si su puerta es de metal aluminio fibra de vidrio o con paneles de vidrio U siempre son necesarios refuerzos pe verticales y horizontales No se incluyen Refuerzo vertical o Linea central SSS vertical de la el Ubicaci n de Ef puerta de garaje la m nsula ie RR de la puerta f No A Perno de coche F s de 5 16 18 por Linea central i Orilla interior de la E F H 2 1 2 pulgadas vertical dela Yr puerta o del refuerzo puerta de garaje de madera M nsula de A A la puerta 0 ee p 7 Arandela de 5 16 de pulg pog Tuerca eS de 5 16 18 oe Figura 1 E Laa o jo PEA paa Llora sc AA M nsula de la puerta Figura 2 PUERTAS DE UNA SOLA PIEZA Lea y respete todas las advertencias e instrucciones respecto a los refuerzos contenidas en la p gina anterior Instalaci n de puertas seccionales ya que todos los refuerzos para su puerta de una sola pieza son los mismos e Coloque la m nsula de la puerta en el centro de la parte superior de la misma alinea
67. do de la puerta se regula hasta qu punto sta se detendra al abrir y al cerrar Para poner en marcha el abridor oprima el bot n de control de la puerta Haga funcionar el abridor durante un ciclo completo del recorrido e La puerta se abre y se cierra completamente e La puerta se mantiene cerrada y no retrocede indebidamente cuando est completamente cerrada Si su puerta pasa estas dos pruebas no necesitar hacer m s ajustes al l mite del recorrido Pero si no pasa la prueba de la retroceso tendr que ajustar el l mite del recorrido Ajustes Paso 3 en la p gina 29 El procedimiento de ajuste se explica a continuaci n Lea el procedimiento con cuidado antes de continuar con el Paso 2 de la secci n de Ajustes Use un destornillador para hacer los ajustes al l mite del recorrido Despu s de llevar a cabo un ajuste haga funcionar el abridor durante un ciclo completo del recorrido NOTA El abrir y cerrar la puerta varias veces durante el procedimiento de ajuste puede causar que el abridor se sobrecaliente y al sobrecalentarse se apagar S lo espere quince minutos y contin e con los ajustes necesarios Si algo interfiere con el recorrido de la puerta en su trayectoria hacia arriba sta se detendr Pero si algo la obstruye en su trayectoria hacia abajo incluyendo un posible desnivel o desbalanceo la puerta retroceder C MO Y CU NDO AJUSTAR LOS L MITES e Si la puerta no se abre completamente per
68. door about 2 5 cm as shown in Figures 1 2 and 3 Figure 1 Fasten straight door arm section to outer trolley with the 5 16 x1 clevis pin Secure the connection with a ring fastener Fasten curved section to the door bracket in the same way using the 5 16 x1 1 4 clevis pin Figure 2 Bring arm sections together Find two pairs of holes that line up and join sections Select holes as far apart as possible to increase door arm rigidity Figure 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sections together Find two pairs of holes that line up and join with bolts lock washers and nuts Pull the emergency release handle toward the opener at a 45 angle so that the trolley release arm is horizontal Proceed to Adjustment Step 1 page 27 Trolley will re engage automatically when opener is operated Figure 1 Figure 2 HARDWARE SHOWN ACTUAL SIZE OO Nut 5 16 18 Clevis Pin 5 16 x1 Trolley Lock Washer 5 16 Clevis Pin 5 16 x1 1 4 Door Bracket Ring Fastener Hex Bolt 5 16 18x7 8 Figure 3 25 Inner Trolley Outer Trolley Ring 7 a Fastener Clevis Pin 5 16 x1 Straight Door Arm Door Bracket Emergency Release Handle Clevis Pin 5 16 x1 1 4 5 16 18
69. e NEVER use handle to pull door open or closed If rope knot becomes untied you could fall DISCONNECT THE TROLLEY The door should be fully closed if possible Pull down on the emergency release handle so that the trolley release arm snaps into a vertical position and lift the door manually The lockout feature prevents the trolley from reconnecting automatically and the door can be raised and lowered manually as often as necessary Trolley Release Arm in Manual Disconnect Position Lockout position Manual disconnect TO RE CONNECT THE TROLLEY Pull the emergency release handle toward the opener at an angle so that the trolley release arm is horizontal The gt Trolley trolley will reconnect on the N aes next UP or DOWN operation es either manually or by using Release Handle the door control or remote Pull at 45 angle A To reconnect CARE OF YOUR OPENER LIMIT AND FORCE ADJUSTMENTS Weather conditions may cause some minor changes in door operation requiring some re adjustments particularly during the first year of operation Pages 27 and 28 refer to the limit and force adjustments Only a screwdriver is required Follow the instructions carefully Repeat the safety reverse test Adjustment Step 3 page 29 after any adjustment of limits or force FORCE CONTROLS LIMIT CONTROLS MAINTENANCE SCHEDULE Once a Month e Manually operate
70. e Premium Control Console 3 Continue holding the ENTER and LIGHT buttons while you press the push bar on the Premium Control Console all three buttons are held 4 Release buttons when the motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard 3 To set the number of hours this temporary PIN will work press the number of hours up to 255 then press OR 3 To set the number of times this temporary PIN will work press the number of times up to 255 then press The opener light will blink once when the temporary PIN has been learned Test by pressing the four buttons for the temporary PIN then press Enter The door should move If the temporary PIN was set to a certain number of openings remember that the test has used up one opening To clear the temporary password repeat steps 1 3 setting the number of hours or times to 0 in step 3 One Button Close Opener can be closed by pressing only the ENTER button if the one button close feature has been activated This feature has been activated at the factory To activate or deactivate this feature press and hold buttons 1 and 9 for 10 seconds The keypad will blink twice when the one button close is active The keypad will blink four times when one button close is deactivated 36 REPAIR PARTS Rail Assembly Parts KEY PART NO NO DESCRIPTION 81C275 Rack 41A6263 Hardware bag includ
71. e bolt head into the slot on each sensor Use wing nuts to fasten sensors to brackets with lenses pointing toward each other across the door Be sure the lens is not obstructed by a bracket extension Figure 5 e Finger tighten the wing nuts Recommended Wire Routing 1 Using insulated staples run the wires from both sensors to the rail at the door header Figure 6 2 Run the wires through wire clip at the top of the rails NOTE If your access door is near the garage door you may choose to install the door control at this time and run the door control wire along the rail with the sensor wires If you choose this option follow instructions 1 3 on page 20 Figure 6 Sensor Wire Sensor eA Figure 5 Carriage Bolt 1 4 20x1 2 Carriage Bolt 1 4 20x1 2 Bell Wire Wing Nut 1 4 20 Pp Lens HARDWARE SHOWN ACTUAL SIZE S Me Wing Nut 1 4 20 Ln Safety Reversing o YN Invisible Light Beam Protection Area Staples An Safety Reversing Sensor Wire Clip INSTALLATION STEP 5 Position the Opener To prevent damage to garage door rest garage door opener rail on 2x4 placed on top section of door CAUTION Follow instructions which apply to your door type as illustrated SECTIONAL DOOR OR ONE PIECE DOOR WITH TRACK A 2x4 laid fla
72. e cinco segundos Si al abrirse la puerta se top con alguna obstrucci n se va a detener 2 3 4 30 9 Cuando se ajusta uno de los controles l mites de fuerza o de recorrido es posible que sea necesario ajustar tambi n el otro control Despu s de llevar a cabo cualquier ajuste SE DEBE probar el sistema de reversa de seguridad El sistema de reversa de seguridad SE DEBE probar cada mes La puerta DEBE invertir su direcci n al entrar en contacto con un objeto de 3 8 cm 1 1 2 de pulg de altura o un tabl n de madera de 2x4 pulg apoyado sobre el piso MANTENGA SIEMPRE LA PUERTA DEL GARAJE DEBIDAMENTE BALANCEADA v ase la p gina 3 Si la puerta no est debidamente balanceada es posible que no retroceda cuando as se requiera y podr a ocasionar una LESION ACCIDENTAL GRAVE o INCLUSO LA MUERTE TODAS las reparaciones necesarias de cables resortes y otras piezas las DEBE llevar a cabo un t cnico especializado en sistemas de puertas pues TODAS estas piezas est n bajo una tensi n EXTREMA SIEMPRE desconecte la alimentaci n de energ a el ctrica al abre puertas de garaje ANTES de llevar a cabo cualquier reparaci n o de quitar las tapas CONSERVE ESTAS INSTRUCCIONES 10 11 7 Si la puerta est completamente abierta no va a cerrar si el rayo est interrumpido El sensor no tiene ning n efecto en el ciclo de apertura Si el sensor no se ha instalado o est desalineado la puerta no
73. e cochera Su abridor Security y el control remoto manual han sido programados en la f brica con un c digo coincidente que cambia cada vez que se usa accesando al azar m s de 100 000 millones de c digos nuevos Su abridor funcionar hasta con 8 controles remotos Security y un sistema de entrada sin llave Security Si compra un control remoto nuevo o si desea desactivar alg n control remoto siga las instrucciones que aparecen en la secci n sobre C mo programar el abridor Active su abridor de alguna de las siguientes maneras e El Control remoto manual Mantenga oprimido el bot n grande hasta que la puerta se empiece a mover El Control de pared de la puerta Mantenga oprimido el bot n hasta que la puerta se empiece a mover La Entrada sin llave Vea Accesorios Si su abridor de puerta de cochera viene con este accesorio deber estar programado antes de usarlo Vea C mo programar el abridor Una vez activado el abridor con el sensor de seguridad de retroceso correctamente instalado y alineado 1 Si la puerta est abierta se va a cerrar Si la puerta est cerrada se va a abrir Si la puerta se est cerrando va a retroceder Si la puerta se est abriendo se va a detener Si la puerta se ha detenido en un punto parcialmente abierta se va a cerrar Si al cerrarse la puerta se top con alguna obstrucci n va a retroceder Si la obstrucci n interrumpe el rayo del sensor las luces del abridor van a parpadear durant
74. e copyright in the garage door opener does not authorize the purchaser or supplier of the non rolling code transmitter to circumvent that technical measure Your garage door opener has already been programmed at the factory to operate with your hand held remote control The door will open and close when you press the large push button Below are instructions for programming your opener to operate with additional Security remote controls To Add or Reprogram a Hand held Remote Control USING THE LEARN BUTTON USING THE PREMIUM CONTROL CONSOLE 1 Press and hold the button on the hand held remote that you wish to operate your garage door 1 Press and release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 While holding the remote button press and hold the LIGHT button on the Premium Control Console 2 Within 30 seconds press and hold the button on the hand held remote that you wish to operate your garage door 3 Continue holding both buttons while you press the push bar on the Premium Control Console all three buttons are 3 Release the button when the motor unit held lights blink It has learned the code If S light bulbs are not installed two clicks will be he
75. e de extension Puerta de acceso EN POSICION CERRADA M nsula del cabezal Riel M nsula del riel Brazo de uerda y manija la puerta recto o y i del sistema de liberaci n de emergencia Pared delantera Brazo M nsula curvo de Puerta s de la la puerta de la r puerta cochera Planificaci n contin a A ADVERTEN Cl A INSTALACI N CON PUERTAS DE UNA SOLA PIEZA Sin un sistema de retroceso de seguridad que funcione debidamente e Generalmente una puerta de una sola pieza no requiere al cerrar la puerta de la cochera se corre el riesgo de que las refuerzos adicionales Si usted tiene una puerta de material personas y en particular los ni os peque os sufran LESIONES liviano y quiere reforzarla consulte la informaci n respecto a GRAVES o INCLUSO LA MUERTE puertas seccionales contenida en Instalaci n Paso 12 e El espacio entre la base de la puerta de la cochera y el piso NO e Dependiendo del dise o de su puerta tal vez necesite piezas DEBE exceder 6 mm 1 4 de pulgada De no ser as el sistema de de montaje adicionales para la m nsula de la puerta retroceso de seguridad no va a funcionar debidamente o Paso 12 e El piso o la puerta de la cochera SE DEBE reparar para eliminar este espacio rR PUERTA DE UNA SOLA PIEZA SIN CARRIL TECHOTERMINADO NR Es necesario m nsula de soporte y accesorios de fijaci n V ase la p gina 19 Pared de cabecera
76. e de soporte del carril ESTAS PIEZAS SE MUESTRAN EN SU TAMA O REAL Manguito de metal Presilla en C Perno hexagonal de 1 4 20x7 16 de pulg Figura 4 Presilla en C Carril central Figura 5 Tirante de soporte del carril Carril central MONTAJE PASO 2 ESTAS PIEZAS SE MUESTRAN EN SU TAMANO REAL Fije el riel a la unidad del motor e instale el trole NOTA Para facilitarle el montaje y la instalaci n del motor vuelva a colocarlo dentro del hule espuma de protecci n retire la espuma despu s de concluir Instalaci n Paso 4 Perno hexagonal de 1 Sobre una superf cie plana alinee el riel ya armado al motor 1 4 20x7 16 de pulg como se muestra en la siguiente ilustraci n 2 Deslice el cople sobre la polea del riel 3 Deslice el riel a trav s de la m nsula del motor hasta que el cople quede bien ajustado sobre la polea del motor 4 Alinee los dos orificios para los pernos del riel con los correspondientes orificios de la m nsula del motor Fije con los pernos hexagonales de 1 4 20x7 16 de pulg y sus respectivas tuercas Apri telos con una llave de tuercas de 3 8 de pulg 5 Para desenganchar el trole baja el brazo de liberaci n Deslice el trole dentro y a lo largo de parte inferior del riel Suba el brazo de liberaci n Eso debe juntar la cremallera y el trole M nsula del motor Pi n del motor Pernos h
77. e eee eee 3 Planificaci n uo ir dls ees wate wena eRe 4 5 Inventario de la caja de cartOn 0 0 0 eee eee 6 Inventario de piezaS oooooocoorccrrcr 7 Montaje 8 11 Monte el rel coord i 8 9 Fije el riel a la unidad del motor y instale el trole 10 Fijaci n de las m nsulas del riel 11 Instalaci n 11 26 Instrucci nes importantes para la instalaci n 11 Determine d nde va a instalar la M nsula del Cabezal 12 Instale la m nsula del cabezal o 13 Colocaci n del riel en la m nsula del cabezal 14 Instale La Sistema de Protecci n 15 17 Coloque el abridor en posici n oooo oo 18 Cuelgue el abridor ooocccccocccococo nooo 19 Instale la unidad de control de la puerta 20 Requisitos para la instalaci n el ctrica 21 Termine la instalaci n del sensor del sistema reversa dE SOQUIAAO cacorioric ir a a E E 21 Instale las luceS oooccocccccoo ea 22 Coloque la cuerda y la manija de emergencia 22 Fije la m nsula de la puerta o ooooccccoocoocoo 23 24 Conecte el brazo de la puerta al trole 25 26 Ajustes 27 29 Ajuste el l mite del recorrido HACIA ARRIBA y HACIA ABAY Ossie so soe ti da lacada aan 27 Ajuste la TUErZaA eens wee a eee ee 28 Pruebe el Sistema de Retroceso de Seguridad 29 Pruebe la Sistema de Protecc
78. e madera de 2x4 pulg acostado en el piso significa que el recorrido HACIA ABAJO cerrar no es suficiente Aumente el l mite del recorrido HACIA ABAJO con el tornillo correspondiente haci ndolo girar 1 4 de vuelta hacia la izquierda NOTA Si su puerta es seccional aseg rese de que los Y e Opere la puerta en la direcci n hacia abajo La puerta deber retroceder autom ticamente al hacer contacto con la obstrucci n ajustes al l mite no hagan que el brazo de la puerta se mueva m s all de una posici n recta hacia arriba y hacia abajo Vea la ilustraci n en la p gina 25 e Repita la prueba e Sila puerta retrocede autom ticamente al hacer contacto con el pedazo de madera de 3 8 cm 1 1 2 de pulg quite la obstrucci n y abra y cierre la puerta completamente por lo menos tres o cuatro veces para verificar que el ajuste sea adecuado e Sila unidad sigue fallando la prueba del sistema de reversa de seguridad llame a un t cnico en sistemas de puertas VERIFICACI N IMPORTANTE DE SEGURIDAD Compruebe el sistema de reversa de seguridad despu s de que e Se hagan ajustes al largo del brazo de la puerta los l mites del recorrido o los controles de la fuerza a e Se hagan reparaciones o ajustes a la puerta de la cochera Pedazo de madera de 3 8 cm 1 1 2 de pulg incluyendo los resortes y la torniller a o un pedazo de madera de 5x10 cm 2x4 pulg acostado sobre el piso e Se hagan reparaciones al piso
79. e secured to two vertical supports A vertical reinforcement brace should cover the height of the top panel The illustration shows one piece of angle iron as the horizontal brace For the vertical brace two pieces of angle iron are used to create a U shaped support Figure 1 The best solution is to check with your garage door manufacturer for an opener installation door reinforcement kit NOTE Many vertical brace installations provide for direct attachment of the clevis pin and door arm In this case you will not need the door bracket proceed to Installation Step 12 SECTIONAL DOORS Center the door bracket on the previously marked vertical centerline used for the header bracket installation Note correct UP placement as stamped inside the bracket Figure 2 Position the bracket on the face of the door within the following limits A The top edge of the bracket 2 4 5 10 cm below the top edge of the door B The top edge of the bracket directly below any structural support across the top of the door Header Bracket A Location a Vertical 193 Centerline Tf i of Garage A Door ds al 5 No at ewe i o o rr 23 CAUTION Fiberglass aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket C
80. ecto de la puerta Manija de emergencia M nsula de la puerta Brazo curvo de la puerta JN Pasador chaveta de Figura 1 5 16x1 1 4 de pulg Arandelas de presi n de 5 16 de pulg Tuercas de 5 16 de pulg 18_ Q Pernos de 5 16 18x7 8 de pulg Arandelas de presi n de Tuercas de 5 16 de pulg 18 Pernos de 5 16 18x7 8 de pulg Corte este extremo Figura 3 TODAS LAS PUERTAS DE UNA SOLA PIEZA M nsula de la puerta 1 Arme el brazo de la puerta Figura 4 LS Anillo sujetador e Sujete las dos secciones de los brazos de la puerta recto y curvo a la mayor distancia posible de manera que dos o tres de los orificios se sobrepongan uno al otro 0 S2 2 Brazo recto e Cierre la puerta y fije la secci n recta del brazo a la m nsula Pasador de Tuerca de 5 16 18 de pulg de la puerta con el pasador de chaveta de 5 16x1 1 4 de All ee pulgada de pulg 5 16 18x7 8 Asegurelos con un anillo sujetador Figura 4 de pulg Brazo curvo 2 Procedimiento de ajuste Figura 5 e Si tiene una puerta de una sola pieza deber ajustar los Oprima el bot n de control de la puerta el trole deber ir l mites del recorrido antes de conectar el brazo de la puerta hasta la posici n completamente cerrada Los tornillos de ajuste del l mite de recorrido se encuentran en el panel del lado izquierdo como se muestra en la ilustraci n que aparece en la p gina 27 Siga el procedimiento
81. en cielo raso Haga los agujeros gu a de 3 16 de pulg y fije la m nsula firmemente a un soporte estructural con los pernos incluidos ESTAS PIEZAS SE MUESTRAN EN SU TAMANO REAL Tirafondos de 5 16x9x1 5 8 de pulg OOOO INSTALACI N DE LA M NSULA DEL CABEZAL EN EL CIELO RASO e Prolongue la l nea vertical de centro hasta el cielo raso tal como se muestra e Centre la m nsula en la marca a no m s de 15 cm 6 pulg de distancia de la pared Aseg rese de que la flecha de la m nsula apunte en direcci n opuesta a la pared La m nsula se puede instalar a ras del cielo raso cuando el espacio disponible es muy reducido e Marque los agujeros laterales Haga los agujeros gu a de 3 16 de pulg y fije la m nsula firmemente a un soporte estructural con los pernos incluidos Este orificio es solamente para marcar la posici n de la m nsula Se deben de utilizar los tornillos tirafondo para sujetar la m nsula Agujeros de montaje en techo 13 Orificios para la instalaci n de pared Este orificio es solamente para marcar la posici n de la m nsula Se deben de utilizar los tornillos tirafondo para sujetar la m nsula Orificios opcionales para la instalaci n en la pared L nea vertical del centro de la puerta Tirafondos de frontal 5 16x9x1 5 8 de pulg Soporte estructural de 3 8 cm 2x4 pulg Resorte de puerta Linea horizontal _ Puerta _ del
82. enn nn en eo ee ee ee Your garage door opener is programmed with self diagnostic capabilities The Learn button diagnostic LED will flash a number of times then pause signifying it has found a potential Dia gno stic Chart issue Consult Diagnostic Chart below 4 FLASH O Symptom One or both of the Indicator lights on the safety sensors do Safety Reversing Sensor not glow steady Safety reversing sensors A a f f wire open broken or e Inspect sensor wires for a short staple in wire correct wiring polarity black white disconnected wires reversed broken or disconnected wires replace attach as needed OR e Disconnect all wires from back of motor unit e Remove sensors from brackets and shorten sensor wires to 1 2 ft 30 60 cm from 2FLASHES back each of sensor e Reattach sending eye to motor unit using shortened wires If sending eye indicator Safety reversing sensors light glows steadily attach the receiving eye wire shorted or black white wire reversed Align sensors if the indicator lights glow replace the wires for the sensors If the sensor indicator lights do not light replace the safety sensors 3 FLASHES IO Symptom LED is not lit on door control e Inspect door control wires for a short staple in wire replace as needed Door control or wire shorted e Disconnect wires at door control touch wires together If motor unit activates replace door control e If m
83. ependiendo de sus necesidades individuales es posible que en algunos casos vaya a necesitar materiales o herramientas que no se incluyen con este producto e Instalaci n Paso 1 Observe la pared o el cielo raso justo por encima de la puerta de la cochera La m nsula del cabezal debe estar firmemente sujeta a los soportes de la estructura e Instalaci n Paso 4 Dependiendo del tipo de construcci n de su cochera es posible que necesite m nsulas de extensi n o bloques de madera para instalar los sensores e Instalaci n Paso 4 El montaje en el piso del sensor que activa el sistema de retroceso de seguridad podr a requerir piezas que no se incluyen e Instalaci n Paso 6 Si el plaf n o cielo raso de su cochera tiene acabado es posible que necesite una m nsula de soporte y o m s pernos y torniller a para la instalaci n e Hay otra puerta que d acceso a la cochera Si no es asi ser necesario contar con el sistema de llave de emergencia Modelo 53702 Vea la p gina de Accesorios INSTALACI N EN UNA PUERTA SECCIONAL Para puertas livianas de garaje de fibra de vidrio acero fino aluminio puertas con paneles de vidrio etc es necesario instalar un refuerzo horizontal y uno vertical V anse m s detalles en la p gina 23 Riel Pared de cabecera 0 gt AGS E gia seguridad de reversa
84. eraci n de la puerta los cuales van a requerir algunos reajustes en particular durante el primer a o de operaci n En las p ginas 27 y 28 se encuentra la informaci n sobre los ajustes de l mite y de fuerza Lo nico que necesita es un destornillador Siga las instrucciones con cuidado Repita la prueba de retroceso de seguridad Ajustes Paso 3 P gina 29 despu s de hacer ajustes a los l mites o la fuerza CONTROLES DE FUERZA A o CONTROLES DE L MITE y CALENDARIO DE MANTENIMIENTO Una vez al mes e Haga funcionar la puerta manualmente Si est desbalanceada o se pandea llame a un t cnico especializado en sistemas de puertas e Revise para cerciorarse de que la puerta se abra y se cierre completamente Ajuste los l mites y o la fuerza de ser necesario vea las p ginas 27 y 28 e Repita la prueba de la retroceso de seguridad Haga los ajustes necesarios vea Ajustes Paso 3 Una vez al a o e Ponga aceite en los rodillos los cojinetes y las bisagras de la puerta El abridor no necesita lubricaci n adicional No lubrique los carriles de la puerta 32 LA BATER A DEL CONTROL REMOTO 44 ADVERTENCIA Para evitar la posibilidad de LESIONES GRAVES o INCLUSO LA MUERTE e NUNCA permita que los ni os peque os est n cerca de las bater as e Si alguien se traga una bater a llame al m dico de inmediato Para reducir el riesgo de incendio explosi n o combusti n qu mica e
85. es sprocket coupling 12B890 Left rail bracket 12B900 Right rail bracket 41A6264 Screw drive rail assembly Complete 7 2 1 m 12B889 Rail support brace 41A6262 Complete trolley assembly 41A4836 Drive sprocket kit NOT SHOWN 28A143 Rail Clips KEY PART NO NO DESCRIPTION 41A4884 Premium control console 41A6140 3 Function remote control case no circuit board 10A20 3V 2032 Lithium battery 29B137 Visor clip 41A2828 Emergency release rope amp handle 41B4494 1 2 Conductor bell wire white white red 41A4353 Header bracket w clevis pin amp fastener 41A5047 Door bracket w clevis pin amp fastener 41A5034 Safety sensor kit receiving and sending eyes with 3 9 m 2 conductor bell wire attached 178B34 Straight door arm section 12B776 Hanging bracket 178B35 Curved door arm section 41A5266 1 Safety sensor bracket 41D543 1 Keyless entry keypad cover 410541 Keyless entry battery cover NOT SHOWN 10A25 Battery 41A4675 9 Installation hardware bag see page 7 114A3607 Owners manual esse ese gegseggg8 Motor Unit Assembly Parts Down Brown Gav LIMIT SWITCH ASSY Wire Center Limit Up Contact Contact iad KEY PART KEY PART NO NO DESCRIPTION NO NO DESCRIPTION 310568 Drive shaft cover 41A4837 1 Worm gear and retainer 41B4245 Line cord 41A6673 Low voltage wire harness 30B652 Capacitor 41A6334 High voltage wire harness 41A3150 Terminal block w screws 41AS175R2S Receiver logic board assembl
86. etenerse Si la puerta no se detiene o es dif cil sostenerla DISMINUYA la fuerza de la puerta HACIA ARRIBA con el control de ajuste d ndole vuelta hacia la izquierda Haga peque os ajustes hasta que la puerta pare f cilmente y abra completamente Despu s de llevar a cabo cada ajuste haga funcionar el abridor durante un ciclo completo del recorrido Si la puerta no se abre por lo menos 1 5 m 5 pies AUMENTE la fuerza del RECORRIDO HACIA ARRIBA abrir con el control de ajuste d ndole vuelta hacia la derecha Haga peque os ajustes hasta que la puerta abra completamente Reajuste el l mite del recorrido HACIA ARRIBA si es necesario Despu s de llevar a cabo cada ajuste haga funcionar el abridor durante un ciclo completo del recorrido 44 ADVERTENCIA Si el sistema de reversa de seguridad no se ha instalado debidamente las personas y los ni os peque os en particular podr an sufrir LESIONES GRAVES o INCLUSO LA MUERTE cuando se cierre la puerta del garaje e Si el l mite de la fuerza del abre puertas de garaje es excesivo habr de interferir con la operaci n adecuada del sistema de auto reversa de seguridad e NUNCA aumente la fuerza m s all de la cantidad m nima que se requiera para cerrar la puerta del garaje e NUNCA use los ajustes de la fuerza para compensar si la puerta del garaje se atasca o se atora e Si se ajusta uno de los controles l mites de la fuerza o del recorrido es posible que sea necesario ajus
87. exagonales de 1 4 20x7 16 de pulg Pernos hexagonales de 1 4 20x7 16 de pulg Riel completo Relleno de espuma 7 Cremallera Al motor Trole 10 MONTAJE PASO 3 Fijacion de las m nsulas del riel e Proceda a alinear las m nsulas en el extremo del riel tal como se muestra en la ilustraci n e Introduzca dos tornillos de cabeza hexagonal de 1 4 20x7 16 de pulg y tuercas de seguridad Ajuste firmemente con una llave tubo de 3 8 de pulg Ha finalizado el ensamblado de su abre puertas de garaje Lea las advertencias siguientes antes de proceder con la secci n de instalaci n INSTALACI N M nsula del riel a Perno hexagonal de 1 4 20x7 16 de pulg Perno hexagonal de 1 4 20x7 16 de pulg ESTAS PIEZAS SE MUESTRAN EN SU TAMA O REAL Perno hexagonal de 1 4 20x7 16 de pulg INSTRUCCIONES IMPORTANTES PARA LA INSTALACI N A amp ADVERTENCIA Para reducir el riesgo de una LESI N GRAVE o LA MUERTE LEA Y SIGA AL PIE DE LA LETRA TODAS LAS INSTRUCCIONES PARA LA INSTALACI N Instale el abridor de puerta de cochera SOLO si la puerta de la cochera est debidamente balanceada y lubricada Si la puerta no est debidamente balanceada es posible que no retroceda cuando se requiera lo que podr a ocasionar una LESION GRAVE o INCLUSO LA MUERTE 3 TODAS las reparaciones de los cables resortes y otras piezas las DEBE llevar a cabo un t cnico especializado en sistemas de p
88. f motor unit above terminal block then into quick connect terminals To release or insert wire push in tab with screwdriver Red White Grey INSTALLATION STEP 8 A WARNING miechical nequirements To prevent possible SERIOUS INJURY or DEATH from To avoid installation difficulties do not run the opener 2ctrocution or fire until Step 9 below e Be sure power is not connected to the opener and disconnect power to circuit BEFORE removing cover to To reduce the risk of electric shock your garage door opener has a grounding type plug with a third grounding pin This plug will only fit into a grounding type outlet If the plug doesn t fit into the outlet you have contact a qualified electrician to install the proper outlet establish permanent wiring connection e Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes e NEVER use an extension cord 2 wire adapter or change plug in ANY way to make it fit outlet Be sure the opener is grounded PERMANENT WIRING CONNECTION If permanent wiring is required by your local code E refer to the following procedure ae Ground Tab To make a permanent connection through the 7 8 hole in Ground Screw the top of the motor unit Remove the motor unit cover screws and set the cover Ground Wire aside Remove the attached 3 prong cord Connect the black line wire to the screw on the brass terminal the white neutral
89. ficar que no se doble ni se pandee Tire de la manija de liberaci n de emergencia y abra y cierre la puerta manualmente Si la puerta se pandea llame a un t cnico especializado en sistemas de puertas Si la puerta no parece estar desbalanceada ni se pandea contin e con el ajuste de la fuerza del movimiento HACIA ABAJO de la puerta cerrada como se indica en el Paso 2 de de la secci n de Ajustes AJUSTES PASO 2 Ajuste de la fuerza Los controles para el ajuste de la fuerza del abridor se encuentran en el panel de posterior de la unidad del motor Estos ajustes controlar n la fuerza que ser necesaria para abrir y cerrar la puerta Si la fuerza es muy d bil es posible que la puerta haga esos molestos retrocesos al cerrarla movimiento hacia abajo y que se detenga al abrirla movimiento hacia arriba El clima puede afectar el movimiento de la puerta as que es posible que tenga que hacer algunos ajustes ocasionalmente El m ximo margen de ajuste de la fuerza es 3 4 de una vuelta no trate de forzar el control m s all de este punto Use un destornillador para hacer los ajustes NOTA Si algo interfiere con el recorrido de la puerta en su trayectoria hacia arriba sta se detendr Pero si algo la obstruye en su trayectoria hacia abajo incluyendo un posible desnivel o desbalanceo esto activar la retroceso y la puerta retroceder C MO Y CU NDO AJUSTAR LA FUERZA DEL ABRIDOR 1 Pruebe la fuerza del recorrido HA
90. flat on floor CAUTION 27 To prevent damage to vehicles be sure fully open door provides adequate clearance eas Limit Adjustment Screws Left Side Panel t Co o ADJUSTMENT LABEL y ADJUSTMENT STEP 2 Adjust the Force Force adjustment controls are located on the back panel of the motor unit Force adjustment settings regulate the amount of power required to open and close the door If the forces are set too light door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction Weather conditions can affect the door movement so occasional adjustment may be needed The maximum force adjustment range is about 3 4 of a complete turn Do not force controls beyond that point Turn force adjustment controls with a screwdriver NOTE If anything interferes with the door s upward travel it will stop If anything interferes with the door s downward travel including binding or unbalanced doors it will reverse HOW AND WHEN TO ADJUST THE FORCES 1 Test the DOWN close force e Grasp the door bottom when the door is about halfway through DOWN close travel The door should reverse Reversal halfway through down travel does not guarantee reversal on a 1 1 2 3 8 cm obstruction See Adjustment Step 3 page 29 If the door is hard to hold or doesn t reverse DECREASE the DOWN close force by turning the contro
91. guen las instrucciones correspondientes El peligro puede ser el ctrico electrocuci n o mec nico Lea las instrucciones con mucho cuidado Cuando vea esta palabra y o s mbolo de seguridad en este manual le alertar de que existe el riesgo de da ar la puerta de la cochera y o el abridor si no se siguen las instrucciones correspondientes Lea las instrucciones con mucho cuidado Preparacion de la puerta de su cochera Antes de comenzar e Quite los seguros e Retire cualquier cuerda o cable que est conectado a la puerta e Haga la siguiente prueba con su puerta para verificar que est balanceada y que no se atore ni se pandee 1 Levante la puerta hasta la mitad de su recorrido como se muestra Suelte la puerta Si est balanceada deber mantenerse en esa posici n con s lo el soporte de los resortes 2 Suba y baje la puerta observe si se atora con algo o si se pandea Si su puerta se atora o se pandea o no est balanceada llame a un t cnico especializado en sistemas de puertas Puerta seccional Puerta de una sola pieza Cinta de medir 44 ADVERTENCIA Para evitar una LESI N GRAVE o INCLUSO LA MUERTE e SIEMPRE llame a un t cnico profesional para que le d servicio a su puerta de cochera si sta se atora se pandea o est desbalanceada Una puerta de cochera que no est bien balanceada puede que no retroceda como se requiere
92. i n oooooo ooooo 29 INTRODUCCION Revisi n de los S mbolos y T rminos de Seguridad Operaci n 30 34 Instrucci nes importantes de seguridad 30 C mo usar su abridor de puerta de cochera 30 C mo usar la unidad de control de la puerta 31 C mo abrir la puerta manualmente 31 Mantenimiento de su abridor de puerta de cochera 32 Si tiene alg n problema oococcccccococc 33 Tabla de diagnostico 0 00 cee om 34 Como Programar el Abridor 35 36 Como agregar o reprogramar un control remoto manual 35 Para borrar todos los c digos de la memoria de la unidad del MOtOF oooccococco e eee 35 Controles remotos de 3 funciones 005 35 C mo agregar reprogramar o cambiar un c digo de entrada sin llave 0 000 cee eee eee 36 Accesorios 37 Garantia 37 Numeros de Servicio Contratapa Este abridor de puerta de cochera ha sido dise ado y probado para un funcionamiento seguro siempre y cuando se instale se pruebe se opere y se le d mantenimiento como se indica en este manual cumpliendo al pie de la letra con todas las advertencias e instrucciones generales aqu contenidas 44 ADVERTENCIA Mec nica A ADVERTENCIA El ctrica PRECAUCI N Estas advertencias y o s mbolos de seguridad que aparecen en este manual le alertar n de que existe el riesgo de una lesi n seria o de muerte si no se si
93. iling to motor unit Use insulated staples to secure wire in several places Do not pierce wire with a staple creating a short or open circuit If your access door is near the garage door you may run this wire with the Safety Reversing Sensor wires along the top of the rail See page 17 4 Insert all wires through the opening on top of motor unit above the terminal block on the back panel Figure 3 Strip 7 16 11 mm of insulation from each set of wires Insert door control wire into quick connect terminals by color white wire to white white red wire to red Separate white and white black wires sufficiently to connect to the opener quick connect terminals Twist like colored wires together Insert wires into quick connect holes white to white and white black to grey NOTE When connecting multiple door controls to the opener twist same color wires together Insert wires into quick connect holes white to white and red white to red 6 Use tacks or staples to permanently attach entrapment warning label to wall near door control and manual release safety reverse test label in a prominent location on inside of garage door NOTE DO NOT connect the power and operate the opener at this time The trolley will travel to the full open al position but will not return to the close position until the poor control Connections sensor beam is connected and properly aligned lt 7116 11 mm gt Strip wire 7 16 11 mm
94. irectly to the use of this product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you DISCLAIMER OF IMPLIED WARRANTIES Except for the motor all implied warranties for this product including but not limited to any implied warranties of merchantability and fitness for a particular purpose are limited in duration to the 91st day through 3 year limited warranty period set forth above All implied warranties with respect to the motor are limited in duration to the 91st day through 7 year limited warranty period set forth above No implied warranties will exist or apply after such periods Some States do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you FROM THE 91ST DAY WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS STORE OR SEARS SERVICE CENTER IN THE UNITED STATES WARRANTY SERVICE IS AVAILABLE BY CALLING 1 800 4 MY HOME This warranty applies only while this product is in use in the United States This warranty gives you specific legal rights and you may also have other rights which vary from state to state Sears Roebuck and Co Dept 817WA Hoffman Estates IL 60179 CONTENIDO Introduccion 2 7 Revisi n de los s mbolos y t rminos de seguridad 2 Preparaci n de la puerta de su cochera 3 Herramientas necesariaS 0000 ee
95. l counterclockwise Make small adjustments until the door reverses normally After each adjustment run the opener through a complete cycle elf the door reverses during the down close cycle and the opener lights aren t flashing INCREASE DOWN close force by turning the control clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount required to close the door 2 Test the UP open force e Grasp the door bottom when the door is about halfway through UP open travel The door should stop If the door is hard to hold or doesn t stop DECREASE UP open force by turning the control counterclockwise Make small adjustments until the door stops easily and opens fully After each adjustment run the opener through a complete travel cycle elf the door doesn t open at least 5 feet 1 5 m INCREASE UP open force by turning the control clockwise Make small adjustments until door opens completely Re adjust the UP limit if necessary After each adjustment run the opener through a complete travel cycle 4 amp WARNING Without a properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door e Too much force on garage door will interfere with proper operation of safety reversal system e NEVER increase for
96. l empaque hasta que la instalaci n y el ajuste se hayan material de empaque ya que en ocasiones las piezas se atoran terminado en el mismo Unidad de control Premium Puntales del soporte del riel 4 Broche de visera para control remoto Control remoto SECURITY de tres botones 2 Acolpe Cable de 2 conductores blanco y blanco rojo Brazo recto de la puerta M nsulas del cabezal y del riel ese 8 ese gesegegseges eg M nsula del cabezal SECURITY Entrada sin llave Etiquetas de seguridad y manual The Protector System 2 Sensores de reversa de seguridad 1 emisor y 1 receptor con cable de 2 conductores blanco y blanco negro conectado M nsulas para sensor de seguridad 2 Inventario de Piezas Antes de la instalaci n organice todas las piezas en grupos como se muestra en la siguiente ilustraci n TORNILLER A Y PIEZAS PARA EL MONTAJE Q da Q o Perno hexagonal de Manguito de metal 2 Presilla en C 2 1 4 20x7 16 de pulg 14 Presilla de cables 6 TORNILLER A Y PIEZAS PARA LA INSTALACI N mw 2 O Perno de coche Tuerca de mariposa Anillo sujetador 3 Tuerca de de 1 4 20x1 2 pulg 2 1 4 20 pulg 2 5 16 18 pulg 8 CT H Tornillo de cabeza cuadrada Perno hexagonal Grapa con de 5 16 9x1 5 8 de pulg 2 de 5 16 18x7 8 pulg 4 Arandela de 5 16 pulg 7 aislamiento 30 SN00000000000 Tornillo de cabeza cuadrada de 5 16 18x1 7 8 pu
97. la puerta de la cochera se est cerrando e Conecte y alinee correctamente el sensor del sistema de retroceso de seguridad Este dispositivo de seguridad es necesario y NO SE DEBE desactivar e Instale el sensor del sistema de retroceso de seguridad de manera que el rayo NO ESTE a m s de 15 cm 6 pulg del piso Las m nsulas para la instalaci n han sido dise adas para que se sujeten directamente al carril de la puerta sin la necesidad de torniller a ni piezas adicionales Si es necesario instalar las unidades sobre la pared aseg rese de que todas las m nsulas est n sujetas a una superficie s lida por ejemplo uno de los soportes de la pared Las m nsulas de extensi n est n disponibles si se necesitan vea la secci n de Accesorios Si va a instalar los sensores sobre ladrillo o mamposter a use un pedazo de madera para evitar hacer orificios innecesarios sobre la mamposter a en caso que necesite cambiarlos de lugar El trayecto del rayo elecr nico invisible debe estar libre de cualquier obstrucci n Ninguna de las partes de la puerta los carriles resortes bisagras rodillos u otras piezas o torniller a debe interrumpir el rayo cuando la puerta se est cerrando o o OL IIII II III III GA Sensor de seguridad de reversa 15 cm 6 pulg sobre el piso m ximo rea protegida Enfrentando la puerta desde el lado interno
98. le 11 mm 7 16 de pulg del extremo del cable de campana y 2 con ctelo a las terminales de tornillo correspondientes al color del cable en la parte posterior de la puerta de la unidad de control blanco a 2 y blanco y rojo a 1 Con un desarmador abra la tapa por el costado Sujete con un tornillo autorroscante de 6AB por 1 1 4 de pulgadas instalaci n est ndar o con un tornillo para metales de 6 32 por 1 pulgadas dentro de la caja m ltiple como se indica a continuaci n e Perfore e instale el tornillo del fondo permitiendo que 3 mm 1 8 de pulg sobresalga sobre la superficie de la pared e Coloque la parte inferior de la unidad de control de la puerta sobre la cabeza del tornillo y desl celo para sujetarlo apriete el tornillo e Taladre y coloque el tornillo de la parte superior con precauci n de no romper la cubierta pl stica de la unidad No apriete en exceso e Inserte las leng etas superiores y cierre la cubierta Instalaci n est ndar solamente Tienda el cable del timbre hacia arriba en la pared y atrav s del cieloraso a la unidad del motor Use grampas aisladas para asegurar el cable en varios lugares No perfore el cable con las grampas lo que puede crear un cortocircuito o circuito abierto Si su puerta de acceso est cerca de la puerta del garage usted pued etender este cable con con el cable del Sensor Inversor de Seguridad a lo Para evitar la posibilidad de una LESI N GRAVE o INCLUSO LA MU
99. le cuando la altura correcta de montaje se la levanta tire del brazo del seguro del trole para separar la parte interna de la externa Deslice el trole externo hacia el motor El trole puede permanecer desconectado hasta el final del Paso 13 Brazo de desenganche del trole ENGANCHADO DESENGANCHADO PUERTA DE UNA SOLA PIEZA SIN RIEL Puede utilizar un tirante de madera de 3 8 cm 2x4 pulg en posici n acostada para determinar la distancia ideal entre la puerta y el riel e Quite el material de empaque e Levante el abre puertas y col quelo sobre una escalera Si la escalera no es lo suficientemente alta va a necesitar ayuda l e Abra la puerta totalmente y apoye un tirante de madera de 3 8 cm 2x4 pulg parado sobre la parte superior de la puerta bajo el riel e La parte superior de la puerta deber a quedar al mismo nivel que el motor No instale el abre puertas a m s de 10 cm 4 pulg arriba de este punto Parte superior de la puerta J El tabl n de 3 8 cm 2x4 pulg se usa para determinar la altura correcta de montaje 18 INSTALACION PASO 6 Cuelgue el abridor Aqu se muestran tres ejemplos distintos para la instalaci n sin embargo es posible que su cochera no concuerde con ninguno de ellos Las m nsulas de soporte deben estar en ngulo Figura 1 para que proporcionen un soporte r gido En caso de
100. lg 2 Tornillo 6ABx1 1 4 pulg 2 Tornillo de 6 32x1 pulg 2 e Perno de coche de 5 16 18x2 1 2 pulg 2 Taquete para muro falso 2 Espaciador 2 Ja Eso E Pasador de chaveta Pasador de ati Pasador de chaveta de 5 16x1 1 2 pulg 1 de 5 16x1 pulg 1 de 5 16x1 1 4 pulg 1 MONTAJE PASO 1 Monte el riel No encienda ni use el abridor hasta que llegue al paso de la instalaci n correspondiente de otra manera corre el riesgo de complicar el proceso de instalacion 1 Abra la caja de carton del carril y saque el contenido colocandolo sobre una superficie de trabajo horizontal Mantenga limpia y sin particulas mientras est trabajando 2 Identifique las secciones de carril y oriente las mismas sobre una superficie plana seg n se muestra El carril trasero tiene un engranaje negro en un extremo El carril delantero tiene un soporte de pl stico negro dentro del carril en el tornillo La secci n restante es el carril central NOTA Tenga cuidado al manipular la secci n del carril central El tornillo puede deslizarse y salirse si la secci n est demasiado inclinada Puntales del soporte del riel Perno hexagonal de le i de pulg Perno hexagonal de 1 4 20x7 16 de pulg PRECAUCI N Para evitar LASTIMARSE al armar el riel mantenga las manos alejadas de las uniones mientras se acoplan los tramos ESTAS PIEZAS SE MUESTRAN EN SU TAMA O REAL Perno hexagonal de 1 4 20x7 16 de pulg
101. loor 1 1 2 3 8 cm board or a 2x4 laid flat 4 amp WARNING Without a properly installed safety reversing sensor persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door 29 OPERATION IMPORTANT SAFETY INSTRUCTIONS A amp WARNING To reduce the risk of SEVERE INJURY or DEATH READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS ALWAYS keep remote controls out of reach of children NEVER permit children to operate or play with garage door control push buttons or remote controls ONLY activate garage door when it can be seen clearly it is properly adjusted and there are no obstructions to door travel ALWAYS keep garage door in sight until completely closed NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR NO ONE SHOULD GO UNDER A STOPPED PARTIALLY OPENED DOOR If possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly NEVER use emergency release handle unless garage doorway is clear of persons and obstructions NEVER use handle to pull garage door open or closed If r
102. m 3 Contin e oprimiendo los dos botones ENTER y LIGHT mientras oprime tambi n la barra de la Consola de Control Premium con los tres botones oprimidos 4 Suelte los botones cuando las luces de la unidad del motor empiecen a N parpadear Ya aprendi el c digo Si no _ ha instalado bombillos se escuchar n N dos chasquidos 3 Para fijar el n mero de horas que el PIN temporal debe funcionar oprima el n mero de horas hasta 255 luego oprima O 3 Para fijar el n mero de veces que el PIN temporal debe funcionar oprima el n mero de veces hasta 255 luego oprima La luz del abridor parpadear una vez cuando el PIN temporal haya sido aprendido Pruebe oprimiendo los cuatro botones correspondientes al PIN temporal luego oprima Enter La puerta debe moverse Si el PIN temporal se ha fijado para abrir la puerta un determinado n mero de veces recuerde que la prueba constituye una vez Para borrar la contrase a temporal repita los pasos del 1 al 3 fijando el n mero de horas o de veces en 0 en el paso 3 Cierre con un bot n El abridor se puede cerrar presionando s lo el bot n ENTER si est activada la funci n de cierre con un bot n Esta funci n viene activada de f brica Para activarla o desactivarla presione y mantenga presionados los botones 1 y 9 durante 10 segundos El teclado parpadear dos veces cuando se active la funci n de cierre con un bot n y parpadear
103. n 6 15 cm above the floor Attach brackets to wall with lag screws not provided If using extension brackets or wood blocks adjust right and left assemblies to the same distance out from the mounting surface Make sure all door hardware obstructions are cleared Floor installation Figure 4 Use wood blocks or extension brackets see Accessories to elevate sensor brackets so the lenses will be no higher than 6 15 cm above the floor Carefully measure and place right and left assemblies at the same distance out from the wall Be sure all door hardware obstructions are cleared Fasten to the floor with concrete anchors as shown HARDWARE SHOWN ACTUAL SIZE mm QP Wing Nut 1 4 20 Carriage Bolt 1 4 20x1 2 Staples Figure 1 DOORTRACK MOUNT RIGHT SIDE Indicator K f Sensor Figure 2 WALL MOUNT RIGHT SIDE Fasten Wood Block to Wall with Lag Screws Not Provided Indicator Light Sensor Bracket Figure 3 WALL MOUNT RIGHT SIDE ide d ns es garage Extension Bracket See Accessories Provided with Extension Bracket Sensor Provided with Bracket Extension sy Bracket Ka Indicator Lens Light Figure 4 FLOOR MOUNT RIGHT SIDE Attach with Concrete Anchors Not Provided Indicator Bracket MOUNTING AND WIRING THE SAFETY REVERSING SENSORS e Slide a 1 4 20x1 2 carriag
104. ner tambi n otoros derechos que var an del estado para indicar Sears Roebuck and Co Dept 817WA Hoffman Estates IL 60179 Get it fixed at your home or ours Your Home For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts amp Repair Center 1 800 488 1222 Call anytime day or night U S A only www sears com To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparacion Au Canada pour service en francais a domicilio y para ordenar piezas 1 800 LE FOYER 1 888 SU HOGAR 1 800 533 6937 1 888 784 6427 Wwww sears ca SEARS O Registered Trademark TM Trademark M Service Mark of Sears Roebuck and Co Marca Registrada Marca de F brica Marca de Servicio de Sears Roebuck and Co MC Marque de comme
105. nes que la luz del indicador de Aprender se m ltiples Security o de un apague aproximadamente 6 segundos Ya minicontrol remoto pueden estar n borrados todos los c digos programarse para operar otros anteriores Vuelva a programar cada uno de los controles abridores de puerta de remotos o la entrada sin llave que desee usar cochera Security C mo agregar reprogramar o cambiar un c digo de entrada sin llave NOTA Su nueva Entrada sin llave debe programarse para que opere el abridor de la puerta de su cochera C MO USAR LA CONSOLA DE CONTROL PREMIUM C MO USAR EL BOT N LEARN APRENDER 1 Oprima y suelte el bot n Aprender de la unidad del motor La luz indicadora de este bot n estar encendida por 30 segundos 2 En los 30 segundos introduzca un n mero de identificaci n personal PIN que haya elegido usando el teclado Luego oprima y mantenga oprimido el bot n ENTER 3 Suelte el bot n cuando las luces de la unidad del motor empiecen a parpadear N Ya aprendi el c digo Si no ha instalado bombillos se escuchar n dos chasquidos N Para cambiar un PIN existente Si el PIN existente ya es conocido una persona lo puede cambiar sin usar una escalera 1 Oprima los cuatro botones que correspondan al PIN actual luego oprima y mantenga oprimido el bot
106. not installed two clicks will be heard To change an existing known PIN If the existing PIN is known it may be changed by one person without using a ladder 1 Press the four buttons for the present PIN then press and hold the button The opener light will blink twice Release the button 2 Press the new 4 digit PIN you have chosen then press Enter The motor unit lights will blink once when the PIN has been learned Test by pressing the new PIN then press Enter The door should move To set a temporary PIN You may authorize access by visitors or service people with a temporary 4 digit PIN After a programmed number of hours or number of accesses this temporary PIN expires and will no longer open the door It can be used to close the door even after it has expired To set a temporary PIN 1 Press the four buttons for your personal entry PIN not the last temporary PIN then press and hold the button The opener light will blink three times Release the button 2 Press the temporary 4 digit PIN you have chosen then press Enter The opener light will blink four times P NOTE This method requires two people if the Keyless Entry is already mounted outside the garage 1 Enter a four digit personal identification number PIN of your choice on the keypad Then press and hold ENTER 2 While holding the ENTER button press and hold the LIGHT button on th
107. nued 3 Attach rail support braces to the back rail Loosely insert 1 4 20x7 16 hex bolts into the aligned holes of the end HARDWARE SHOWN ACTUAL SIZE rail and rail support brace Figure 1 Do not finger tighten 4 Extend the drive screw a few inches from the center rail and slide the sleeve onto the long journal Figure 2 5 Interlock the long and short journal of the center and Mea Sleeve PORDON ic back rails Slide the sleeve over the journal connection Figure 3 6 Place the c clip onto the long journal shaft center rail to ensure that the sleeve does not slide Figure 4 7 Slide the center rail so that the center rail and rail brace holes are aligned Figure 5 Secure with bolts 8 Tighten all hex bolts 9 Repeat steps 3 8 for header section Figure 1 Figure 4 Metal Sleeve Rail Support Brace q Oo 2 Center Rail Rail Support Brace Figure 2 Figure 5 Drive Screw Metal Sleeve Rail Support Brace Center Rail Center Rail Figure 3 Short Journal Long Journal Metal Sleeve A Rail Support Brace ASSEMBLY STEP 2 HARDWARE SHOWN ACTUAL SIZE Fasten the Rail to the Motor Unit and Install the Trolley NOTE To aid in assembly and installation replace the foam packing around the motor unit Remove it after Hex Bolt 1 4 20x7 16 Inst
108. o abre por lo menos 1 5 m 5 pies Aumente el l mite del recorrido HACIA ARRIBA D vuelta al tornillo de ajuste del l mite hacia arriba gir ndolo hacia la derecha Cada vuelta del tornillo equivale a 5 cm 2 pulg del recorrido NOTA Para evitar que el trole golpee el perno de la cubierta de protecci n mantenga una distancia m nima de 5 a 10 cm 2 a 4 pulg entre el trole y el perno e Si la puerta no se abre por lo menos 1 5 m 5 pies Ajuste la fuerza del movimiento hacia arriba de la puerta abierta como se indica en el Paso 2 de la secci n de Ajustes e Si la puerta no cierra completamente Aumente el l mite del recorrido hacia abajo D vuelta al tornillo de ajuste del l mite del recorrido hacia la izquierda direcci n opuesta a las manecillas del reloj cada vuelta del tornillo equivale a 5 cm 2 pulg del recorrido Si a n despu s de este ajuste y del trole contra m nsula de la polea del cable p gina 4 la puerta contin a sin cerrar completamente alargue el brazo de la puerta p gina 25 y disminuya el l mite del recorrido hacia abajo e Si la puerta retrocede cuando est en la posici n completamente cerrada Disminuya el l mite del recorrido hacia abajo D vuelta al tornillo de ajuste del l mite del recorrido hacia la derecha direcci n de las manecillas del reloj cada vuelta del tornillo equivale a 5 cm 2 pulg del recorrido 44 ADVERTENCIA Si el sistema de auto reversa de
109. oes not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won t close completely try lengthening the door arm page 25 and decreasing the down limit If the opener reverses in fully closed position Decrease down travel Turn the down limit adjustment screw clockwise One turn equals 2 5 cm of travel If the door reverses when closing and there is no visible interference to travel cycle If the opener lights are flashing the Safety Reversing Sensors are either not installed misaligned or obstructed See Troubleshooting page 21 Test the door for binding Pull the emergency release handle Manually open and close the door If the door is binding or unbalanced call for a trained door systems technician If the door is balanced and not binding adjust the DOWN close force See Adjustment Step 2 4 amp WARNING Without a properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door e Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system e If one control force or travel limits is adjusted the other control may also need adjustment e After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with 1 1 2 high 3 8 cm object or 2x4 laid
110. om hand held remote controls However the door will open and close from the Door Control the Outdoor Key Switch and the Keyless Entry Accessories To activate press and hold the Lock button for 2 seconds The push button light will flash as long as the Lock feature is on To turn off press and hold the Lock button again for 2 seconds The push button light will stop flashing The Lock feature will also turn off whenever the learn button on the motor unit panel is activated Additional feature when used with the 3 Function hand held remote To control the opener lights In addition to operating the door you may program the remote to operate the lights 1 With the door closed press and hold a small remote button that you want to control the light 2 Press and hold the Light button on the door control 3 While holding the Light button press and hold the Lock button on the door control 4 After the opener lights flash release all buttons Light Button Lock Button 31 To Open the Door Manually 4 amp WARNING To prevent possible SERIOUS INJURY or DEATH from a falling garage door e f possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly e NEVER use emergency release handle unless garage doorway is clear of persons and obstructions
111. ontact your door manufacturer for reinforcement kit HARDWARE SHOWN ACTUAL SIZE Nut 5 16 18 Lock Washer 5 16 Carriage Bolt 5 16 18x2 1 2 e Mark and drill 5 16 left and right fastening holes Secure the bracket as shown in Figure 1 if there is vertical reinforcement If your installation doesn t require vertical reinforcement but does need top and bottom fastening holes for the door bracket fasten as shown in Figure 2 Horizontal and vertical reinforcement is needed for lightweight garage doors fiberglass aluminum steel doors with glass panel etc Not Provided Vertical orcement Vertical Centerline Carriage Bolt 5 16 18x2 1 2 Inside Edge of Door or Door Bracket Lock Washer 5 16 We Nut 5 16 18 Figure 1 Door Bracket Figure 2 ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also e Center the door bracket on the top of the door in line with the header bracket as shown Mark either the left and right or the top and bottom holes e Drill 5 16 pilot holes and fasten the bracket with hardware supplied If the door has no exposed framing drill 3 16 pilot holes and fasten the bracket with 5 16 x1 1 2 lag screws not provided to the top of the door NOTE The door bracket may be installed on the top edge of the
112. ope and handle clear the tops of all vehicles to avoid entanglement Secure with an overhand knot NOTE If it is necessary to cut the rope heat seal the cut end with a match or lighter to prevent unraveling 22 CAUTION To prevent possible OVERHEATING of the endpanel or light socket DO NOT use short neck or specialty light bulbs DO NOT use halogen bulbs Use ONLY incandescent To prevent damage to the opener e DO NOT use bulbs larger than 100W ONLY use A19 size bulbs 100 Watt Max Standard Light Bulb 100 Watt Max Standard A Gy Light Bulb Release Tab Release Tab 4 amp WARNING To prevent possible SERIOUS INJURY or DEATH from a falling garage door e f possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly e NEVER use emergency release handle unless garage doorway is clear of persons and obstructions e NEVER use handle to pull door open or closed If rope knot becomes untied you could fall Trolley fi i S IRN E sn Trolley Release Arm Overhand Knot Emergency Release Handle INSTALLATION STEP 12 Fasten the Door Bracket Follow instructions which apply to your door type as illustrated below or on the following page A horizontal reinforcement brace should be long enough to b
113. ope knot becomes untied you could fall Using Your Garage Door Opener Your Security opener and hand held remote control have been factory set to a matching code which changes with each use randomly accessing over 100 billion new codes Your opener will operate with up to eight Security remote controls and one Security Keyless Entry System If you purchase a new remote or if you wish to deactivate any remote follow the instructions in the Programming section Activate your opener with any of the following e The hand held Remote Control Hold the large push button down until the door starts to move e The wall mounted Door Control Hold the push button or bar down until the door starts to move e The Keyless Entry See Accessories lf provided with your garage door opener it must be programmed before use See Programming When the opener is activated with the safety reversing sensor correctly installed and aligned 1 If open the door will close If closed it will open 2 If closing the door will reverse 3 If opening the door will stop 4 If the door has been stopped in a partially open position it will close 5 If obstructed while closing the door will reverse If the obstruction interrupts the sensor beam the opener lights will blink for five seconds 9 If one control force or travel limits is adjusted the other control may also need adjustment 10 After ANY adjustments are made the safet
114. ores al abridor Alg n cable roto 2 Si la luz indicadora del sensor que emite el rayo enciende y permanece encendida pero la luz del otro sensor no enciende e Verifique que est n correctamente alineados e Verifique que no haya un corto en el cable del sensor receptor 3 Si la luz indicadora del sensor receptor esta d bil o baja verifique la alineaci n de los sensores NOTA Si la trayectoria del rayo invisible se ve obstruida o est fuera de alineaci n al tratar de cerrar la puerta sta se abrir autom ticamente Si la puerta est abierta simplemente no se podr cerrar y las luces de abridor parpadear n diez veces vea la p gina 15 INSTALACION PASO 10 PRECAUCION Instale las luces Oprima las leng etas de liberaci n a ambos lados de la lente Rote la lente suavemente hacia atr s y hacia abajo hasta que la bisagra quede en la posici n totalmente abierta No quite la lente Instale bombillos de 100 vatios como m ximo en cada portal mpara Los bombillos deben ser de A19 cuello standard s lo En cuanto se conecte la electricidad las luces se encender n y permanecer n encendidas por aproximadamente cuatro minutos y medio luego las luces se apagan Invierta el procedimiento para cerrar la lente Para reemplazo uso los bombillos para el abridor de puerta de cochera de A19 estandar NOTA S lo utilice bombillos est ndar El uso de bombillos de cuello corto o especiales puede sobrecalen
115. ot Provided e Bolt 5 16 18x7 8 A e Lock Washer 5 16 e Nut 5 16 18 Bolt 5 16 18x7 8 Lock Washer 5 16 Nut 5 16 18 Figure 3 Lag Screws a A 5 16 18x1 7 8 E aN Not Provided Bolt 5 16 18x7 8 Lock Washer 5 16 Nut 5 16 18 INSTALLATION STEP 7 Install the Door Control Locate door control within sight of door at a minimum height of 5 feet 1 52 m where small children cannot reach away from moving parts of door and door hardware If installing into drywall drill 5 32 holes and use the anchors provided For pre wired installations as in new home construction it may be mounted to a single gang box Figure 2 1 Strip 7 16 11 mm of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color white wire to 2 and white red wire to the 1 2 Remove cover by gently prying at slot in side of the cover with a small flat head screwdriver Fasten with 6ABx1 1 4 self tapping screws drywall installation or 6 32x1 machine screws into gang box as follows e Drill and install bottom screw allowing 1 8 3 mm to protrude above wall surface e Position bottom of door control on screw head and slide down to secure Adjust screw for snug fit e Drill and install top screw with care to avoid cracking plastic housing Do not over tighten e Insert top tabs and snap on cover 3 Standard installation only Run bell wire up wall and across ce
116. otor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with jumper wire If motor unit activates replace door control wires 4 FLASHES HA Symptom Sending indicator light glows steadily receiving indicator light is dim or flashing Safety reversing sensors i ai slightly misaligned e Realign receiving eye sensor clean lens and secure brackets dim or flashing LED e Verify door track is firmly secured to wall and does not move 5 FLASHES AA dee Symptom Motor has over heated the motor unit does not operate RPM Sensor Short travel 6 8 15 20 cm Motor overheated or i i possible RPM sensor Unplug unit to reset Try to operate motor unit check diagnostic code failure Unplug to reset e If it is still flashing 5 times and motor unit moves 6 8 15 20 cm replace RPM sensor e If motor unit doesn t operate motor unit is overheated Wait 30 minutes and retry If motor unit still will not operate replace logic board 6 FLASHES ae ba Symptom Motor unit doesn t operate Motor Circuit Failure e Replace logic board because motor rarely fails Replace Receiver Logic Board PROGRAMMING NOTICE If this Security garage door opener is operated with a non rolling code transmitter the technical measure in the receiver of the garage door opener which provides security against code theft devices will be circumvented The owner of th
117. rce MP Marque d pos e de Sears Roebuck and Co 114A3607B O 2008 Sears Roebuck and Co
118. relating to sectional doors in Installation Step 12 e Depending on your door s construction you may need additional mounting hardware for the door bracket Step 12 ONE PIECE DOOR WITHOUT TRACK Access Door AA Safety Reversing Gap between floor Sensor and bottom of door must not exceed 1 4 6 mm y Reversing Sensor FINISHED CEILING Support bracket amp fastening hardware is required See page 19 Wall mounted Door Control Access Door cap between floor Reversing Sensor and bottom of door Safety must not exceed 1 4 6 mm Reversing Sensor of pet 4 amp WARNING Without a properly working safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door e The gap between the bottom of the garage door and the floor MUST NOT exceed 1 4 6 mm Otherwise the safety reversal system may not work properly e The floor or the garage door MUST be repaired to eliminate Rail Bracket Motor unit CLOSED POSITION Emergency Release Rope amp Handle Straight Door Arm CLOSED POSITION Rail Bracket Trolley Bracket eo Header Curved TITS gt
119. rline Bracket Of Garage Door l Door Lag Screws 5 16 9x1 5 8 Header Wall Garage Door Centerline of Garage Door INSTALLATION STEP 3 Attach the Rail to the Header Bracket e Position the opener on the garage floor below the header bracket Use packing material as a protective base NOTE If the door spring is in the way you ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the header rail bracket against the header bracket e Align the bracket holes and join with a clevis pin 5 16 x2 3 4 as shown Spacer can be installed on either side of rail e Insert a ring fastener to secure Ring Fastener Header Bracket Clevis Pin lt 5 16 x2 3 4 Neat Header Rail Bracket Garage Door Opener Carton or Temporary Support HARDWARE SHOWN ACTUAL SIZE Ho A O O Clevis Pin 5 16 x2 3 4 Ring Fastener Spacer INSTALLATION STEP 4 Install The Protector Systeme The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR When properly connected and aligned the sensor will detect an obstacle in the path of its electronic beam The sending eye with an amber indicator light transmits an invisible light beam to the receiving eye with a green indicator light If an obstru
120. s NOTA Si la distancia total supera la altura disponible de el Tf garaje use la altura maxima posible o consulte la pagina 13 para obtener informacion sobre la instalacion en el cielo raso Pared de cabecera Pared de cabecera 2222222 7 5 cm 3 pulg Z IZ III 177 ESAS NAAA RARA AA Punto m s alto de recorrido Puerta seccional con gu a curva Puerta de una pieza con riel gu a horizontal e Punto m s alto de recorrido Accesorios de montaje de la puerta Articulaci n Puerta de una pieza sin riel gu a Puerta de una pieza sin riel gu a accesorios de montaje accesorios de articulaci n 12 INSTALACION PASO 2 Instale la m nsula del cabezal La m nsula del cabezal se puede fijar a la pared sobre la puerta del garaje o en el cielo raso Siga las instrucciones que sean m s adecuadas para las necesidades de su instalaci n No instale la m nsula del cabezal en paneles huecos de pared Si va a fijar la m nsula del cabezal en mamposter a h galo con anclajes para concreto no incluidos INSTALACI N DE LA M NSULA DEL CABEZAL EN LA PARED e Centre la m nsula en la l nea vertical de centro con el borde inferior sobre la l nea horizontal tal como se indica en la ilustraci n y con la flecha orientada hacia el techo e Marque la ubicaci n de los agujeros verticales de la m nsula no utilice los agujeros destinados a montaje
121. s de puertas para la instalaci n de un abridor NOTA Muchas de las instalaciones con soporte o puntal vertical toman en cuenta la instalaci n directa de los pasadores de chaveta y el brazo de la puerta En este caso no necesitar instalar la m nsula para la puerta proceda al Paso 12 PUERTAS SECCIONALES e Coloque la m nsula para la puerta sobre la linea central vertical que hab a marcado previamente para la instalaci n de la m nsula del cabezal Aseg rese de que la leyenda UP arriba est en la posici n correcta como est indicado en la parte interior de la m nsula Figura 2 e Coloque la m nsula sobre la parte frontal de la puerta dentro de los l mites siguientes A El borde superior de la m nsula 5 10 cm 2 4 pulg debajo del borde superior de la puerta B La orilla superior de la m nsula debe estar directamente debajo de alg n soporte de la estructura a lo largo de la parte superior de la puerta M nsula del cabezal 23 PRECAUCI N En el caso de puertas de fibra de vidrio aluminio o acero ligero ES NECESARIO colocar un refuerzo ANTES de instalar el marco de la puerta P ngase en contacto con el fabricante de su puerta para obtener un kit de refuerzo ESTAS PIEZAS SE MUESTRAN EN SU TAMA O REAL Arandela de 5 16 de pulg Tuerca de 5 16 18 de pulg Perno
122. sor Uini a receives he sendera Deam When 1e green NOTE When the invisible beam path is obstructed or indicator light glows steadily tighten the wing nut misaligned while the door is closing the door will reverse If the door is already open it will not close The opener lights will flash 10 times see page 15 21 INSTALLATION STEP 10 Install the Lights Press the release tabs on both sides of lens Gently rotate lens back and downward until the lens hinge is in the fully open position Do not remove the lens Install a 100 watt maximum light bulb in each socket Light bulb size should be A19 standard neck only The lights will turn ON and remain lit for approximately 4 1 2 minutes when power is connected Then the lights will turn OFF Reverse the procedure to close the lens Use A19 standard neck garage door opener bulbs for replacement NOTE Use only standard light bulbs The use of short neck or speciality light bulbs may overheat the endpanel or light socket INSTALLATION STEP 11 Attach the Emergency Release Rope and Handle Thread one end of the rope through the hole in the top of the red handle so NOTICE reads right side up as shown Secure with an overhand knot at least 1 2 5 cm from the end of the rope to prevent slipping Thread the other end of the rope through the hole in the release arm of the outer trolley Adjust rope length so the handle is 6 1 83 m above the floor Ensure that the r
123. t is convenient for setting an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help Sa E at this point if the ladder is not tall enough Topor Door See iF e Open the door all the way and place a 2x4 laid flat on fe the top section beneath the rail Boor Misas e If the top section or panel hits the trolley when you raise eet dd the door pull down on the trolley release arm to disconnect inner and outer sections Slide the outer trolley toward the motor unit The trolley can remain disconnected until Installation Step 13 is completed Trolley Release Arm ENGAGED RELEASED ONE PIECE DOOR WITHOUT TRACK A 2x4 on its side is convenient for setting an ideal door to rail distance Remove foam packaging e Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough e Open the door all the way and place a 2x4 on its side on the top section of the door beneath the rail e The top of the door should be level with the top of the motor unit Do not position the opener more than 4 10 cm above this point 2x4 is used to determine the correct mounting height from ceiling INSTALLATION STEP 6 Hang the Opener Three representative installations are shown Yours may be different Hanging brackets should be angled Figure
124. tar el panel o la portal mpara INSTALACI N PASO 11 Coloque la cuerda y la manija de emergencia Pase un extremo de la cuerda a trav s del orificio que se encuentra en la parte superior de la manija roja de manera que la palabra NOTICE aviso sea legible como se indica en la ilustraci n Aseg rela con un nudo por lo menos a 2 5 cm 1 pulg del extremo de la cuerda para evitar que se resbale Pase el otro extremo de la cuerda a trav s del orificio del brazo de liberaci n del trole exterior Ajuste el largo de la cuerda de tal manera que la manija quede a 1 83 m 6 pies del piso Haga un nudo para asegurarla Para evitar que la cuerda o la manija se enganche en algo aseg rese de que no toquen el techo de ning n veh culo NOTA Si es necesario cortar la cuerda queme con un cerillo o un encendedor el extremo que cort para sellarla y evitar que se desenrede 22 Os de 100 vatios m ximo Leng eta Para evitar un posible SOBRECALENTAMIENTO del portabombillas e NO utilice bombillas de cuello corto ni de tipo especial NO utilice bombillas hal genas Utilice S LO bombillas incandescentes Para evitar da o al abridor e NO utilice bombillas m s grande que 100W e S LO utilice bombillas de tama o A19 Bombillo est ndar Bombillo est ndar de 100 vatios m ximo A S de liberaci n Leng eta de liberaci n Bisagra de la lente Bisagra de la lente 44 ADVERTE
125. tar tambi n el otro control e Despu s de llevar a cabo cualquier ajuste SE DEBE probar el sistema de auto reversa de seguridad La puerta DEBE retroceder al entrar en contacto con un objeto de 3 8 cm 1 1 2 de pulg de altura o un tabl n de madera de 2x4 pulg acostado en el piso Controles de ajuste de fuerza de accionamiento Panel posterior ETIQUETA DE AJUSTE DE FUERZA Fuerza de cierre Fuerza de apertura AJUSTES PASO 3 4 ADVERTENCIA Pruebe el Sistema de retroceso de seguridad Si el sistema de reversa de seguridad no se ha instalado PRUEBA debidamente las personas y los ni os peque os en particular podr an sufrir LESIONES GRAVES O INCLUSO LA MUERTE cuando se cierre la puerta del garaje e El sistema de reversa de seguridad SE DEBE probar cada mes e Abra completamente la puerta coloque un pedazo de madera de 3 8 cm 1 1 2 de pulg o un pedazo de madera de 5x10 cm 2x4 pulg acostado sobre el piso en el centro de la i A puerta de la cochera e Si se ajusta uno de los controles l mites de la fuerza o del recorrido es posible que sea necesario ajustar tambi n el otro control e Despu s de llevar a cabo cualquier ajuste SE DEBE probar el sistema de reversa de seguridad La puerta DEBE retroceder al AJUSTE entrar en contacto con un objeto de 3 8 cm 1 1 2 de pulg de e Sila puerta se detiene al toparse con la obstrucci n esto altura o un tabl n d
126. tener un cielo raso acabado Figura 2 y Figura 3 instale una m nsula de metal resistente en alg n soporte de la estrucura antes de instalar el abridor No se incluye esta m nsula ni la torniller a 1 Mida la distancia desde cada lado de la unidad del motor hasta el soporte de la estructura 2 Corte las dos partes de las m nsulas colgantes a la medida adecuada 3 Taladre los orificios de 3 16 de pulgada en los soportes de la estructura 4 Fije un extremo de cada m nsula al soporte con tornillos de cabeza cuadrada de 5 16 18x1 7 8 de pulg 5 Fije el abridor a las m nsulas colgantes con pernos hexagonales de 5 16 18x7 8 de pulg y sus tuercas y arandelas correspondientes 6 Verifique que el abridor est centrado sobre la puerta o alineado con la m nsula del cabezal si la m nsula no est centrada sobre la puerta 7 Quite el pedazo de madera de 5x10 cm 2x4 pulg Haga funcionar la puerta manualmente Si la puerta golpea el riel suba la m nsula del cabezal NOTA NO conecte el abridor a la fuente de energ a el ctrica en este momento ESTAS PIEZAS SE MUESTRAN EN SU TAMA O REAL OOOO ODO Tornillo de cabeza cuadrada de 5 16 18x1 7 8 de pulg Perno hexagonal de 5 16 18x7 8 de pulg Tuerca de 5 16 18 de pulg Arandela de 5 16 de pulg 44 ADVERTENCIA Para evitar la posibilidad de una LESI N GRAVE si se cayera accidentalmente el abre puertas f jelo FIRMEMENTE a soportes estruct
127. tically turns opener lights on for 5 minutes when it detects a person entering the garage Sensor can be easily deactivated when desired Plug In Light Control Enables homeowner to turn on a lamp television or other appliance from car bedside or anywhere in the home with a remote CRAFTSMAN GARAGE DOOR OPENER LIMITED WARRANTY 90 DAY IN HOME FULL WARRANTY ON PRODUCT For 90 days from the date of purchase this product will be repaired free of charge if defective in material or workmanship ADDITIONAL LIMITED WARRANTY ON PARTS From the 91st day up to 3 year from the date of purchase replacement parts for any defective parts on this product will be furnished free of charge You pay for labor ADDITIONAL LIFETIME LIMITED WARRANTY ON MOTOR From the 91st day and through 7 years if the motor on this product is defective a replacement motor will be furnished free of charge You pay for labor WARRANTY RESTRICTION This Craftsman Garage Door Opener Limited Warranty does not cover light bulbs or repair parts necessary because of operator abuse or negligence including the failure to install adjust and operate this garage door opener according to instructions contained in the owner s manual This limited warranty also does not cover any problems caused by interference LIMITATION ON LIABILITY Seller will not be liable for loss or damage to property or any incidental or consequential loss or expense from property damage due directly or ind
128. tions below apply to your installation Additional materials may be required You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener Depending on your requirements there are several installation steps which may call for materials or hardware not included in the carton Installation Step 1 Look at the wall or ceiling above the garage door The header bracket must be securely fastened to structural supports Installation Step 4 Depending upon garage construction extension brackets or wood blocks may be needed to install sensors Installation Step 4 Alternate floor mounting of the safety reversing sensor will require hardware not provided Installation Step 6 Do you have a finished ceiling in your garage If so a support bracket and additional fastening hardware may be required SECTIONAL DOOR INSTALLATION Horizontal and vertical reinforcement is needed for lightweight garage doors fiberglass steel aluminum door with glass panels etc See page 23 for details Header Wall Torsion mounted Door Control Centerline _ of Garage Door I GIS Safety Reversing Sensor Gap between floor and bottom of door must not exceed 1 4 6 mm Safety Reversing Sensor Extension O
129. to en el control o en uno de sus cables diagn stico Unidad de diagn stico en el motor Sensor de seguridad de reversa instalada Sy CEN El abre puertas de garaje tiene un sistema de autodiagn stico Cuando la luz del bot n Aprendizaje Learn destella y luego hace una pausa significa que puede haber un problema Consulte la siguiente Tabla de Diagn stico Bot n de Aprendizaje Learn A il O S ntoma Una o ambas luces indicadoras de los sensores de seguridad no est n encendidas Inspeccione los cables de los sensores posible cortocircuito en un grapa de fijaci n verifique la polaridad de los cables conexi n invertida de cables negro y blanco un cable podr a estar cortado o desconectado cambie o conecte el cable seg n sea necesario Desconecte todos los cables de la parte trasera del motor Desmonte los sensores de las m nsulas y acorte los cables 1 o 2 pies 30 a 60 cm hacia atr s de cada sensor Vuelva a conectar al motor los cables del emisor del haz Si la luz indicadora del emisor se enciende conecte el receptor Proceda a alinear los sensores si las luces indicadoras se encienden cambie los cables de los sensores Si las luces indicadoras no se encienden cambie los sensores de seguridad S ntoma La luz LED del control no se enciende Inspeccione los cables y el control para detectar si hay
130. uertas ANTES de instalar el abridor Quite TODOS los seguros y retire TODAS las cuerdas conectadas a la puerta de la cochera ANTES de instalar el abridor para de evitar que se enreden Instale el abridor de la puerta de cochera a una distancia de 2 13 m 7 pies del piso Monte la manija de liberaci n de emergencia a una distancia de 1 83 m 6 pies del piso NUNCA conecte el abridor de la puerta de cochera a una fuente de energ a el ctrica hasta que as se indique NUNCA lleve puestos relojes anillos ni ropa muy floja mientras est instalando o dando servicio al abridor pues podr an atorarse en la puerta de la cochera o en los mecanismos del abridor Instale el control de pared de la puerta de cochera e de manera que quede a la vista desde la puerta de la cochera e fuera del alcance de los ni os y a una altura m nima de 1 5 m 5 pies e lejos de TODAS las partes m viles de la puerta Coloque la calcoman a que advierte sobre el riesgo de atraparse cerca del control de la puerta de la cochera en la pared Coloque la calcoman a que contiene la prueba de retroceso de seguridad y liberaci n de emergencia a plena vista en la parte interior de la puerta de la cochera Al concluir la instalaci n pruebe el sistema de retroceso de seguridad La puerta DEBE retroceder al entrar en contacto con un objeto de 3 8 cm 1 1 2 de pulg o bien con un pedazo de madera de 5x10 cm 2x4 pulg puesto pl
131. un cortocircuito por ejemplo en una grapa de fijaci n y repare lo que sea necesario Desconecte los cbles del control y haga contacto entre ellos Si el motor arranca cambie el control e Si el motor no arranca desconecte del panel del motor los cables que vienen del control 4 DESTELLOS Sensores de seguridad levemente desalineados luz d bil o destellante 5 DESTELLOS Haga un puente moment neo entre los terminales rojo y blanco Si el motor arranca cambie los cables entre el control y el motor S ntoma La luz indicadora del emisor est encendida normalmente pero la luz del receptor se enciende d bilmente o intermitentemente e Alinear el receptor limpiarlo y reajustar la m nsula e Verifique que el riel gu a de la puerta est firmemente unido a la pared y que no se mueva S ntoma El motor se ha sobrecalentado el motor no funciona o el trole se ha trabado en el peron de tope El motor zumba brevemente sensor de RPM Recorrido corto de Sobrecalentamiento del motor o falla del sensor de RPM Desenchufe la unidad para reponer su estado 15 a 20 cm 6 a 8 pulg e Desenchufe la unidad para reponer su estado Trate de hacer funcionar el motor revise el c digo de diagn stico e Si todavia est destellando 5 veces y el motor se mueve unas 15 a 20 cm 6 a 8 pulg cambie el sensor de RPM e Si el motor no funciona se ha sobrecalentado Espere 30 minutos y vuelva a intentar 6 DESTELLOS PH
132. ura 2 Junte las dos secciones del brazo localizando dos pares de orificios que se puedan alinear Seleccione dos orificios que est n tan separados como sea posible para aumentar la rigidez del brazo de la puerta e Figura 3 Opciones para alinear los orificios En caso de que los orificios del brazo curvo no se puedan alinear con los orificios del brazo recto desconecte el brazo recto y corte aproximadamente 15 cm 6 pulg del extremo que no tiene orificios Vuelva a conectarlo al trole con el extremo cortado hacia abajo como se muestra Junte las dos secciones de los brazos Localice dos pares de orificios de ambas secciones que se puedan alinear y nalos con tornillos arandelas y tuercas e Tire de la manija de emergencia hacia el abridor en un ngulo de 45 grados de manera que el brazo de liberaci n del trole est en posici n horizontal Proceda a la secci n de Ajustes Paso 1 en la p gina 27 El trole volver a estar listo autom ticamente cuando se opere el abridor ESTAS PIEZAS SE MUESTRAN EN SU TAMA O REAL Tuerca de Arandela de Anillo sujetador 5 16 18 de pulgada 5 16 de pulgada O ol Perno Pasador de chaveta de Pasador de chaveta de hexagonal de 5 16x1 de pulg para el trole 5 16x1 1 4 de pulg para 5 16 18x7 8 la m nsula de la puerta de pulgada 25 Trole Trole interior exterior Pasador chaveta de Anillo sujetador 5 16x1 de pulg T Brazo r
133. urales del garaje Se DEBEN usar sujetadores para concreto si alguno de los soportes se va a instalar en mamposter a 19 Soportes de la estructura Figura 1 Mida la distancia 4 Tornillos de cabeza cuadrada de 5 16 18x1 7 8 pulg Pernos de 5 16 18x7 8 pulg Tuercas de 5 16 pulg Arandelas de 5 16 18 pulg Figura 2 Soporte de la estructura no visible M nsula no se incluye se incluyen no Pernos de 5 16 18x7 8 pulg Pernos de Tuercas de 5 16 pulg 5 16 18x7 8 pulg Arandelas de 5 16 18 pulg Tuercas de 5 16 pulg Arandelas de 5 16 18 pulg Figura 3 Tornillos de cabeza cuadrada de 5 16 18x1 7 8 pulg no se incluyen Pernos de 5 16 18x7 8 pulg Tuercas de 5 16 pulg Pernos de Arandelas de 5 16 18 pulg 5 16 18x7 8 pulg Tuercas de 5 16 pulg Arandelas de 5 16 18 pulg INSTALACION PASO 7 A 4 ADVERTENCIA Instale la unidad de control de la puerta Ubique el control de la puerta de manera que quede a la vista desde la puerta y a una altura m nima de 1 5 m 5 pies donde los ni os peque os no lo puedan alcanzar y lejos de las partes m viles de la puerta y de la torniller a Si se va instalar en un muro falso taladre dos orificios de 5 32 de pulg y use los sujetadores que se incluyen Para una instalaci n pre cableada por ejemplo en una casa en construcci n los modelos de consola se pueden instalar en una caja m ltiple est ndar Figura 2 1 Pe
134. wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded e Reinstall the cover To avoid installation difficulties do not run the opener at this time White Wire Black Wire INSTALLATION STEP 9 TROUBLESHOOTING THE SAFETY REVERSING Complete the Safety Reversing Sensor SENSORS Installation 1 If the sending eye indicator light does not glow steadily after installation check for ALIGNING THE SAFETY REVERSING SENSORS A Elecnciawerte eo ner e Plug in the opener The indicator lights in both the e A short in the white or white black wires These can sending and receiving eyes will glow steadily if wiring occur at staples or at opener connections connections and alignment are correct e Incorrect wiring between sensors and opener The sending eye amber indicator light will glow regardless e A broken wire of alignment or obstruction If the green indicator light in 2 If the sending eye indicator light glows steadily but the the receiving eye is off dim or flickering and the invisible receiving eye indicator light doesn t light beam path is not obstructed alignment is required e Check alignment e Loosen the sending eye wing nut and readjust aiming e Check for an open wire to the receiving eye directly at the receiving eye Lock in place 3 If the receiving eye indicator light is dim realign either e Loosen the receiving eye wing nut and adjust the sensor sen
135. y 41D4671 Limit switch assembly 41A5594 6 Cover 41A6671 Motor drive assembly 41C22 1 Drive coupling hub 20B21 1 Drive belt 175B88 Light socket 41C4672 Screw drive RPM kit 108D77 Light lens 38 ACCESSORIES 139 53702 Emergency Key Release Required for a garage with NO access door Enables homeowner to open garage door manually from outside by disengaging trolley 8 Foot Rail Extension To allow an 8 foot door to open fully Support Brackets For finished ceilings or where additional support is required based on garage construction Includes brackets and fastening hardware Door Clearance Brackets For Sectional Doors Only Replaces top brackets and rollers on door to reduce height of door travel For use when installing opener in garage with low headroom clearance Extension Brackets Available only through Sears Parts amp Service Optional For safety sensor installation onto the wall or floor WARRANTY 139 53753 139 53752 SF 139 53754 SECURITY 3 Function Remote Control Includes visor clip SECURITY Compact 3 Function Remote Control With loop for attaching key ring SECURITY Keyless Entry Enables homeowner to operate garage door opener from outside by entering a password Also can add a temporary password for visitors or service persons Motion Detecting Control Console Motion Detecting Control Console with motion sensor that automa
136. y reversal system MUST be tested 11 Safety reversal system MUST be tested every month Garage door MUST reverse on contact with 1 1 2 high 3 8 cm object or a 2x4 laid flat on the floor 12 ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED see page 3 An improperly balanced door may not reverse when required and could result in SEVERE INJURY or DEATH 13 ALL repairs to cables spring assemblies and other hardware ALL of which are under EXTREME tension MUST be made by a trained door systems technician 14 ALWAYS disconnect electric power to garage door opener BEFORE making ANY repairs or removing covers 15 SAVE THESE INSTRUCTIONS 6 If obstructed while opening the door will stop 7 If fully open the door will not close when the beam is broken The sensor has no effect in the opening cycle If the sensor is not installed or is misaligned the door won t close from a hand held remote However you can close the door with the Door Control the Outdoor Key Switch or Keyless Entry if you activate them until down travel is complete If you release them too soon the door will reverse The opener lights will turn on under the following conditions when the opener is initially plugged in when power is restored after interruption when the opener is activated They will turn off automatically after 4 1 2 minutes or provide constant light when the Light feature on the Premium Control Console is activated Bulb size is A19
137. z indicadora de este bot n estar encendida por 30 segundos Oprima y mantenga oprimido el bot n del control remoto manual que desee usar para la puerta de su cochera 2 Mientras mantiene oprimido el bot n oprima el bot n de la luz LIGHT de la Consola de Control Premium 2 En los 30 segundos oprima y mantenga oprimido el bot n del control remoto manual que desee usar para su puerta de cochera 3 Contin e oprimiendo los dos botones mientras oprime tambi n la barra de la Consola de Control Premium con los tres botones oprimidos 3 Suelte el bot n cuando las luces de la unidad del motor empiecen a parpadear N Ya aprendi el c digo Si no se han 4 Suelte los botones cuando las luces de la puesto bombillos se escuchar n dos unidad del motor empiecen a parpadear E chasquidos Ya aprendi el c digo Si no se han puesto S bombillos se escuchar n dos chasquidos Para borrar todos los c digos de la Controles Remotos de 3 Funciones memoria de la unidad del motor Si es provisto con su abridor de puerta de la cochera el bot n Para desactivar cualquier control remoto que no desee usar grande ha sido programado en la f brica para operaci n de su antes que nada borre todos los c digos abridor Los botones Oprima y mantenga oprimido el bot n adicionales de cualquier Aprender de la unidad del motor hasta control remoto de funcio

Download Pdf Manuals

image

Related Search

Related Contents

1.準備する 4.使ってみる スマートフォン or タブレットを使う場合  Curtis 1620S User's Manual  Saeco Saeco Syntia Cappuccino Carafe Kit HD8145/03  Installation Guide and User Manual  STELLA - Shopify  12 VOLTS - Automatisme de portail  取扱説明書 使用方法    [ siamo pronti al soccorso più pronto che immagini ] We are safety  S4 PAR User Manual 0107.book  