Home

American Dynamics RJ1SNUD-1 Installation guide

image

Contents

1. Adding access holes to the enclosure The J Box meets the NEMA 4 standard for weatherproofing To maintain this rating make sure any hole you drill in the enclosure is thoroughly sealed with silicone based RTV compound Switching to 240Vac If using 240Vac to drive the J Box you must change jumper terminations on the primary winding of transformer Refer to label inside cover of J Box Approved power cords Use only regulatory approved polarized power cords Socket outlet For installation using a line cord the socket outlet must be installed near the equipment and at an easily accessible location F r Installationen mit einem Stromkabel mu die Steckdose an einem Standort installiert werden welcher einfachen Zugang erlaubt This product does not support Manchester protocol It will support SensorNet USE ONLY WITH American Dynamics products and other approved products from Sensormatic Electronics Corporation See inside for additional safeguards SENSORNET SINGLE POSITION JUNCTION BOX J BOX INSTALLATION GUIDE 8000 2573 21 REV F SensorNet Single Position J Box Specifications REG ID SV JBOX1 Product Codes RJ1ISNUD ee RJISNUD 1 o oo Transformer primary jumpers 120V with North American line cord 230V with Continental European line cord and mains line cord are field changeable to support either 120Vac or 230Vac Electrical POWEP SOUICE 00cccceeeeeeee RUSO eee
2. Solution First check both fuses then look for open or loose wire connections at TB1 If loose reconnect wires Measure voltage across 0 and 24V taps of secondary winding on transformer If open replace transformer See Removing the Transformer opposite No Data Check for loose wires If OK see Testing for Power and Data on page 7 Removing the Circuit Board Follow steps to remove the circuit board Reverse steps to reassemble 1 Loosen four captive screws to release cover 2 Remove six screws to remove circuit board Figure 9 Figure 9 4 i N Screws 6 Removing the Transformer Follow steps to remove the transformer Reverse steps to reassemble 1 Loosen four captive screws to release cover 2 As shown in Figure 10 loosen two screws shown in and slide chassis in direction of arrows Gently lay chassis on inside front cover while working on transformer Slide PCB chassis out of box Figure 10 Screws 2 UY 3 Remove four nuts to remove transformer Figure 11 Figure 11 Nuts 4 SENSORNET SINGLE POSITION JUNCTION BOX J BOX INSTALLATION GUIDE 8 of 10 8000 2573 21 REV F Ordering Parts Only the following parts can be ordered SensorNet PC Board 0312 0512 02 5 Pin Connector 2109 0254 04 4 Pin Connector 2109 0254 03 Power Transformer 5604 0205 01 Cable Strain Relief 3100 0035 11 Fuse 5111 0017 21 These p
3. eet ses Max operational limits Input Current eee Operational Diagnostic LEDs Mechanical Environment Wall mounting options Dimensions H x W x D Mounting area H x W Weight ciiise Construction 100 120Vac or 200 240Vac 50 60Hz 3 15A type IEC127 sheet III 90 135Vac or 180 265Vac 50 60Hz 1 0A 5A 26Vac 2 4A max Class 2 LPS Gas Discharge tube impulse rated at 8 20us impulse discharge current 10kA Host aux dome activity noise power On Off switch SpeedDome Ultra outdoor housing Indoor Outdoor concrete wood sheet rock 200 x 200 x 132mm 7 87 x 7 87 x 5 19 in 281 x 200mm 11 x 8 in 3 7 kg 8 25 Ibs Polycarbonate non metallic enclosure Light gray 2 quick release latches 3 inch NPT strain relief fittings provided for power host and dome cables SensorNet Communication Interface Cable distance J Box to J BOX eee 1km 3000ft Host to J BOX nsee 1km 3000ft J Box to camera dome Limited by the length of the low voltage ac power cable See Table 1 on page 6 Cable type siiis unshielded twisted pair 22AWG non polarized Surge protection ee Isolation transformer coupled 2000 Vrms gas discharge tube impulse rated at 10kA 8 20us TVS rated at 1W Connectors for host aux and COME ose Pluggable Euro style Environmental Weatherproof standard NEMA 4 IP
4. ground a Remove PC board assembly and chassis assembly from box Figure 4a b Remove power cord and attach conduit to box Ensure connections are liquid tight c Remove racks screw assemblies and band from clamp package Carefully uncoil band and cut it in half to form two bands d With words this side up etched in rack facing up insert rack into screw assembly Figure 4b Then turn screw just enough to engage rack Prepare two racks this way 2 As shown in Figure 4c with J Box on ground and its rear facing towards you a Slip one of the two bands through closed slots in lower mounting bracket Pick slots appropriate for the width of the pole b Bend end of left side of band inward c Slip bent end through large slot in screw assembly and flatten tight with fingers d Repeat for upper mounting bracket 3 Place box in its mounting location against pole Then wrap both band assemblies around pole so screws are opposite J Box 4 Holding J Box in place perform the following for each band a Cut band to length at a point 2 54cm 1in beyond first notch in band Figure 4d b Using your fingers flatten the last 2 54cm 1in of band inward to form a hook Insert hook through remaining slot in rack and turn screw to secure J Box to pole Figure 4e 5 Run cables and attach wires See Connecting AC Power and Connecting Power and Data Cables Caution Do not use power cord supplied with box fo
5. own expense EQUIPMENT MODIFICATION CAUTION Equipment changes or modifications not expressly approved by Sensormatic Electronics Corporation the party responsible for FCC compliance could void the user s authority to operate the equipment and could create a hazardous condition WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose Further Sensormatic Electronics Corporation reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of Sensormatic Electronics Corporation to notify any person of such revision or changes LIMITED RIGHTS NOTICE For units of the Department of Defense all documentation and manuals were developed at private expense and no part of it was developed using Government Funds The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of limited rights in paragraph a 15 of the clause of DFARS 252 227 7013 Unpublished rights reserved under the Copyright Laws of the United States COPYRIGHT NOTICE SpeedDome and American Dynamics are registered trademarks of Sensormatic Electronics Corporation Other product names if any mentioned herein may be trademarks or registered trademarks of Sensormatic or ot
6. 222 gt AMERICAN gt DYNAMICS SensorNet Single Position Junction Box J Box Installation Guide Figure 1 SensorNet J Box Cover Retaining Screws Plastic 4 On Off Switch 2 C foo 4 HP Access for Cables Latches 2 from Host and Dome RJ1SNUD and RJ1SNUD 1 Series Spare Fuses 2 This weather tight box Figure 1 provides Class 2 LPS power and data to the new SpeedDome Ultra outdoor camera housing IMPORTANT Read Regulatory Requirements and other declarations on page 8 2006 Sensormatic Electronics Corp IMPORTANT SAFEGUARDS The J Box is a 10A 2 pole ganged disconnect device which also provides short circuit and overload protection and has a minimum 3mm open circuit clearance in accordance with the National Electric Code and applicable local codes must be installed at a location readily accessible to the equipment Ein 10A 2 poliges gekoppeltes Ausschaltgerat welches auch uber einen Kurzschlu sowie Uberbelastungsschutz verf gt und einen minimum 3mm offenen Schaltabstand aufweist nach Ubereinstimmung mit den Nationalen Elektrischen Regelungen sowie lokalen Regeln mu an einem Standort installiert werden welcher einfachen Zugang zum Ger t erlaubt Outside elements To keep outside elements from entering the J Box always mount it vertically with cable exits facing down and tighten the four plastic screws
7. 66 Operating temperature 40 C to 50 C 40 F to 122 F Storage temperature 10 C to 50 C 14 F to 122 F Relative humidity 0 to 95 non condensing Regulatory EMG einai bein 47 CFR Part 15 Class A EN55022 Class B IMMUNI esient EN50082 1 SAEY itinerarii UL1950 CSA 22 2 No 950 EN60950 See additional declarations on last page SENSORNET SINGLE POSITION JUNCTION BOX J BOX INSTALLATION GUIDE 2 of 10 8000 2573 21 REV F Mounting the J Box This section explains how to mount the J Box to a wall or pole Parts Required Installation Kit 0351 1646 01 includes 5810 5081 111 2880 0011 2880 0073 01 Screw Self tapping 4 8x25 PHP 4 Anchor Bolt 20x2 w Hardware 4 Anchor Toggle Nylon 8 10 Screw 4 CAUTION Before you begin do the following Mount the box near an accessible ac outlet Always use dedicated unswitched and properly grounded 24 hour ac power Power should be supplied in accordance with local codes Mount the J Box so its power on off switch is readily accessible and its strain relief fittings are face down Indoor Wall Mounting Mount the J Box to the wall as follows Figure 2 1 Using the upper and lower mounting brackets of the box as templates mark mounting hole locations The two center top slots in the upper bracket match the bolt spacing used for older J Boxes CAUTION J Box meets NEMA 4 standard for we
8. arts are shown bold in Figure 12 Figure 12 Exploded view of SensorNet J Box Circuit Board 0312 0512 02 5 Pin Connector 2109 0254 04 4 Pin Connector 2109 0254 03 Circuit Board Assy Chassis Fuses 5111 0017 21 Transformer 5604 0205 01 8 Strain Relief 3 3100 0035 11 SENSORNET SINGLE POSITION JUNCTION BOX J BOX 8000 2573 21 REV F INSTALLATION GUIDE 9 of 10 Declarations This product can only be used with American Dynamics products and other approved products from Sensormatic Electronics Corporation When the unit is hard wired the disconnect device circuit breaker must be readily accessible To meet regulatory approvals only use approved polarized plug cordsets Install the AC outlet near the equipment where it is easily accessible FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his
9. atherproofing To maintain this rating ensure holes drilled in the enclosure are thoroughly sealed with silicone based RTV compound All outdoor wiring must be through conduit and tighten the four plastic screws 2 Install the J Box to drywall concrete or wood see note below e Drywall Use four self tapping screws and Nylon anchors provided e Concrete Use four anchor bolts provided Use a 6 3mm 1 4in masonry bit not provided to drill screw holes e Wood Use four self tapping screws Note To facilitate installation use the two open slots in the lower mounting bracket to rest the box on the screws while inserting screws through the upper bracket 3 Tighten mounting hardware to secure the J Box Figure 2 Wall mounting the J Box 200mm 7 9 114 3mm 4 5 76 2mm 3 0 SENSORNET SINGLE POSITION JUNCTION BOX J BOX INSTALLATION GUIDE 3 of 10 8000 2573 21 REV F Outdoor Pole Mounting Outdoor mounting Figure 3 requires that PC board chassis and power cord be removed to facilitate attachment to pole PC board and chassis are reattached once box is secured Note Pole Mount Kit RHOPM supplied with the pole mount structure includes straps sufficient for 10 30 5cm 4 12in wide poles For larger widths order an additional kit Figure 3 Outdoor pole mount a Straps P N 6010 0043 01 Rear of J Box b lt 1 On the
10. e Table 1 above Note Power data and video cables can be ordered separately or within a composite cable ordered in various lengths Plenum rated cables must be used in indoor ceilings used for environmental air return called other air space in the National Electrical Code Order parts through your distribution network If you order cable from an outside source wire colors may be different SENSORNET SINGLE POSITION JUNCTION BOX J BOX INSTALLATION GUIDE 6 of 10 8000 2573 21 REV F Procedure 1 Turn power switch in J Box to off 0 Power LED should be off 2 Route power and data cables through strain relief fittings in bottom of box Referring to Figure 8 3 Connect power and data cables to 5 pin compression connector supplied on board Color code shown is for composite cable 5 Pin Compression Connector Description reo gent BLK s een soona 4 Plug 5 pin connector into receptacle P1 Wire Color YEL WHT 5 Connect auxiliary and host data cables to 4 pin compression connector P8 supplied on board Color code shown is for composite cable 4 Pin Compression Connector Wire Color Description 6 Plug 4 pin connector into receptacle P8 7 Place jumper JW1 Dome across pins 1 2 to terminate J Box default setting when the J Box is to be the end point of a data line Place JW1 across pins 2 3 unterminated if the J Box is to be the hub of a star network F
11. her companies No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics Corporation RLI CSD 04 2006 www americandynamics net SENSORNET SINGLE POSITION JUNCTION BOX J BOX INSTALLATION GUIDE 10 of 10 8000 2573 21 REV F
12. or jumpers JW2 and JW3 See Communications Protocols and Cable Networks 8000 2573 19 Figure 8 PCB connectors and jumpers F pad ola Bi le 1 2 Terminated 2 3 Unterminated Default setting AUX JW4 PN E E HOST Jw2 SensorNet PCB SNet BRN eee BLK Gnd RED P1 AC WHT SNet YEL v N Gea Power and Data 1poooo00 1 i o Aux ng Aux Host Blh Aux Data e AC PWR E 5Vdc FALSE CD 123 456 AUX HOST Testing for Power and Data LEDs on the circuit board Figure 8 verify that power and data are entering the J Box Indication AC PWR Glows yellow to indicate 24 volt AC power from transformer 5Vdc Glows green to indicate DC power from on board regulator False CD Glows red for 1 2 sec to indicate spurious false carrier detects Carrier Glows yellow to indicate Detect 123 communications from connector P1 to dome Carrier Detect 456 is not used Carrier Detect Aux Glows yellow to indicate communications from auxiliary device Carrier Glows yellow to indicate Detect Host communications from Host Retriggerable indicators remain on if triggered faster than the remaining time SENSORNET SINGLE POSITION JUNCTION BOX J BOX INSTALLATION GUIDE 7 of 10 8000 2573 21 REV F Host and Troubleshooting Problem Possible
13. r outdoor installations Figure 4 Pole mount details a _ Remove PC 6 board assembly H Remove chassis assembly Discard power cord c b C fe a Nx Band 2 Rear of Box a a Band 1 0 TO hs d Cut SENSORNET SINGLE POSITION JUNCTION BOX J BOX INSTALLATION GUIDE 4 of 10 8000 2573 21 REV F Connecting AC Power The J Box comes wired for 120Vac and has a 2m 6ft 7in SJT 3 conductor power cord attached Plug the cord into a dedicated 24 hour unswitched outlet If the box is to be driven by 240Vac then the power cord if used and jumpers across the primary winding of the transformer within the box will have to be changed Figure 6 CAUTION Use only regulatory approved polarized power cords Hardwiring the J Box If the box is to be hardwired to the ac source then the chassis within the box and the power cord will have to be removed to facilitate connection Refer to Figures 5 6 and 13 for how to remove these parts CAUTION Keep the disconnect device circuit breaker readily accessible when hardwiring J Box Do the following 1 Unplug line cord from ac outlet 2 Loosen two screws then slide and lift PC board assembly to remove and access ac connections Figure 5 Figure 5 Accessing connections Q mp if Loosen screws then slide and lift PC board assembly to remove 3 Disconnect ac power co
14. rd from TB1 Figure 6 4 Loosen four screws to detach chassis 5 Detach strain relief securing cord and remove cord refer to Figure 12 Figure 6 Transformer compartment detail Chassis TB1 Power On Off Transformer 24V Switch i TB1 L1 O 12V vo GND Chassis Connections d BI oT o 0 N L2 GND Transformer Primary Jumper Settings 120Vac 1 3 2 4 240Vac 2 3 AC Line Connections eater Pin Function Green E1 Ground E1 Ground Yellow Black 2 Neutral N L2 2 Neutral N L2 Black 3 Line L1 3 Line L1 SENSORNET SINGLE POSITION JUNCTION BOX J BOX INSTALLATION GUIDE 5 of 10 8000 2573 21 REV F 6 Run conduit and ac cable to box and clamp conduit in place Figure 7 7 Reattach chassis Figure 7 Conduit attachment iia Conduit Fuse holders Wire ac line to TB1 and jumper primary taps of transformer according to ac source refer back to Figure 6 120Vac Place a jumper across taps 1 and 3 and another jumper across taps 2 and 4 240Vac Place a jumper across taps 2 and 3 only Reattach PC board assembly Changing the Fuse To reduce the risk of fire replace fuses with the same type and rating 3 15A type IEC127 sheet Ill The part number for the fuse i
15. s 5111 0017 21 Two spare fuses are provided inside the cover To access fuse use a small slotted screwdriver to unscrew the cap of the fuse holder Figure 7 and lift out the fuse Connecting Power and Data Cables Note Incoming and outgoing video cables are connected together within the box No termination exists for video cables within the J Box Power Cable Requirements The low voltage power cable runs between the J Box and the camera dome The length of this cable depends on the ac line voltage See Table 1 for cable lengths based on worst case low line voltages for Japan 100Vac North America 120vac and Europe 240vac Table 1 Cable length vs line voltage 30m 50m 80m 100ft 160ft 260ft 100m 160m 320ft 520ft 50m 80m 160ft 260ft 100m 160m 320ft 520ft Data Cable Requirements Worst Case Line Voltages 90 Vac Japan 102 Vac 60m N Amer 200ft 180 Vac Europe 204 Vac Europe 30m 100ft 60m 200ft The data cable contains one non polarized 22AWG unshielded twisted pair Up to 1km 3000ft of data cable can be run from the Host to the J Box or from J Box to J Box see CAUTION below For more information about the SensorNet communication protocol and possible cable network configurations see Communication Protocols and Cable Networks 8000 2573 19 CAUTION The data cable from the J Box to the dome is limited by the length of the power cable Se