Home

Zigen ZIG-HDMI-UCE User manual

image

Contents

1. 1 Flow control None ZIG POE RXAV COMMANDS Set volume range 136dB to 10dB 1dB steps rxav 01 vol 25 Set device rxav 01 volume to 25dB Response rxav 01 vol x Increase volume rxav 01 volup Increase device rxav 01 volume by 1dB Response rxav 01 vol x Decrease volume 20 ZIG POE RXAV USER MANUAL ZIGEN rxav 01 voldn Decrease device rxav 01 volume by 1dB Response rxav 01 vol x Bass level range 10dB to 10dB in 2dB steps rxav 01 bass 6 Set device rxav 01 bass level to 6dB Response rxav 01 bass x Treble level range 10dB to 10dB in 2dB steps rxav 01 treb 2 Set device rxav 01 treb level to 2dB Response rxav 01 treb x Mute on off rxav 01 mute on Set device rxav 01 mute on Response rxav 01 mute x Relay 1 on off rxav 01 rel1 on Set device rxav 01 relay 1 to ON position Response rxav 01 rel1 x Relay 2 on off rxav 01 rel2 on Set device rxav 01 relay 2 to ON position Response rxav 01 rel2 x Get Device Status rxav 01 st Get device rxav 01 status Response rxav 01 st power x vol x bass x treb x mute x relay1 x relay2 x Display Device Info rxav 01 man Get device rxav 01 device information Response rxav 01 Zigen Corp ZIG POE RXAV fw1 ver xx fw2 ver yy ZIIENCOFP COM Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Power on off rxav 01 pwr off Set device rxav 01 power off Res
2. support 5V OR 12V IR signals Zigen extenders support from 3V up to 12v This is a great feature when using it with 3rd party controllers that output different voltages ex Control4 uses 3V Connect IR inputs to receive remote control signals for routing back to the transmitter via HDBaseT and the on to the source device you want to control Connect IR outputs to your display or projector to control is from a source on transmitter 4 HDBaseT Input plug HDBaseT RJ45 input signal from HDBaseT transmitter Maximum cable length is 100 meters 328 5 Relays 2 3 pin phoenix style connectors captive screw NC normally closed G ground and NO normally open Use to insert in circuit of device you want to trigger examples include masking screens screen control lighting features etc 6 Power connector 2 pin phoenix style captive screw connect to 24VDC power block supplied with the unit ZIIENCOFP COM Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Captive Screw Connectors pin outs are also located on the top of the unit 2 pin connector for power e Power connect black wire to negative terminal e Power connect white wire to positive terminal 3 pin connector for relays e Relays there are settings for both NO and NC for each relay control via WebOS or 3 party controller 12 ZIG POE RXAV USER MANUAL ZIGEN 4 pin connector for connec
3. use near water Itis better to keep it in a dry environment The system should be installed indoor only Only use the power cord supplied with the device Do not use liquid or aerosol cleaners to clean the device Always unplug the power to the device before cleaning Unplug the power cord during lightning or after a prolonged period of non use to avoid damage to the equipment ZIIENCOFP COM Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Introduction HDBaseT 328 100M Receiver RX perfect for classrooms boardrooms huddle rooms and more POE 4K UHD and 4K UHD scaler built in amplifier that strips from HDMI 2 Ethernet ports 2 relays WebOS Also includes IR and RS232 Package Contents 1 x ZIG POE RXAV 1 x 24V 2 5A DC Power Supply IEC USA AC Cord 3 5 x Male Captive Screw Connectors 2 pin power 3 pin Relays x 2 NC G NO 4 pin speakers 5 pin IR Remote Control 1 x User Manual Features 48V IEEE POE WebOS Control 2 Ethernet LAN ports Built in Class D Amp 20 watts per channel stereo Built in 4K UHD Scaler Supports HDMI 1 2 1 3 and 1 4 with 48 bit deep color Supports digital video formats up to 4K UHD 2160P60 4 2 0 pixel format Supports uncompressed PCM 2 Ch 5 1 7 1 Dolby Digital DTS Dolby TrueHD DTS HD Master Audio and more Bi directional IR 3V to 12V Bi directional RS 232 2 Relays for Contact Closure RS 232 Command Set for 3 Party control 4 ZIG P
4. Length of CAT cable being reported by HDBaseT chip this is not always 100 accurate especially with shorter cables Remote HDBaseT POEWP in this case Link Green when there is an HDBaseT connection HDMI Green when HDMI is present Mode Solid green when HDCP is present flashing green when no HDCP detected Cable Length of CAT cable being reported by HDBaseT chip this is not always 100 accurate especially with shorter cables Device Name amp Notes Device Name default out of the box is ZIG POE RXAV XXXX last 4 digits of the serial number You should change it if you are using more than 1 device Change Name below to whatever you want ex CR100RX for conference room number 100 receiver Notes free form field for entering installer notes Control Defaults Relay 1 checking box changes the state of the relay NC G NO Relay 2 checking box changes the state of the relay NC G NO Audio Mute Mutes the audio from the built in amplifier Volume Control Control volume Bass Control the bass of the audio Treble Control the treble of the audio RS232 Baud Rate use to match the speed of your 3 party control system Firmware Reset Info 18 ZIG POE RXAV USER MANUAL ZIGEN e Serial Number serial number of RXAV e Firmware Current firmware revision e Hardware for internal use e IP Address IP address of the unit assigned by your DHCP Server e Hostname th
5. OE RXAV USER MANUAL ZIGEN Specifications Ports Inputs HDBaseT RJ 45 Outputs HDMI x 1 L R Audio stereo via 4 pin female locking connector Phoenix 20W per channel Class D Control Access IR in out 3 5mm stereo IR in out female locking connector Phoenix Power female 2 pin locking connector 24V internal step up transformer to get 48V IEEE POE source 2 Ethernet 10 100 BaseT RJ 45 2 Relay Contact Closures 2 pin locking connectors Phoenix Distance between TX and RX Full HDBaseT 328 or 100M 2160P60 4 2 0 8 bit Copy Protection Compliance HDCP Yes 1 4 includes functionality to overcome the problem when displays don t implement clock stretching Video Bandwidth 10 2 Gbps Video Timings 480i 480p 720p 1080i 1080p 1920x1200 2K and 4K 4K 2K 30Hz 24bpp 4K 2K 60Hz 24bpp with 4 2 0 pixel format ZIIENCOFP COM Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Audio Stereo 20W per channel RMS Class D Amplifier 4K UHD Scaler Scales 1080P24 30 generally a movie incoming signal up to 2160P24 30 Wall Mountable Yes Power Consumption Depends on POE requirements Without POE 5W With POE gt 5W up to around 13W gt 18W Dimensions 5 9 x 2 9 x 95 inches 150 x 74 x 24 millimeters Weight 67 pounds 303 grams Certifications Compliance FCC HDBaseT CE RoHS HDCP HDMI Works With Any properly implemented HDBaseT trans
6. ZIGEN Zigen HDBaseT Receiver 330 ft POE 4K UHD Scaler 20W per channel Amplifier Ethernet ports Relays IR and RS 232 ZIG POE RXAV a JK ZIGEN w ZIG POE RXAV HDMI Extender Scaler www ZigenCorp com ce USER MANUAL Ver 1 0 Zigencorp com Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Table of Contents Copyright and Trademark 3 Introduction 4 Package Contents 4 Features 4 Specifications 5 Panel Description Right Side 7 Panel Description Left Side 10 Captive Screw Connections 12 Connection and Installation 14 Initial Connections 15 Remote Control 16 WebOS Interface 17 RS 232 Commands 20 Warranty 23 2 ZIG POE RXAV USER MANUAL ZIGEN Copyright and Trademarks All rights reserved by ZIGEN INC No part of this document may be reproduced in any form or by any means without written permission from the product manufacturer Changes are periodically made to the information in this document They will be incorporated in subsequent editions The product manufacturer may make improvements and or changes in the product described in this document at any time All the registered trademarks referred to this manual are belonging to their respective companies Before You Begin Follow all instructions marked on the device during using Do not attempt to maintain the device by yourself any faults please contact your vendor Provide proper ventilation and air circulation and do not
7. e repair or replacement of such products In no event shall ZIGEN be responsible or liable for any damage arising from the use of such defective products whether such damages be direct indirect consequential or otherwise and whether such damages are incurred by the reseller end user or any third party The information in this manual has been carefully checked and is believed to be accurate However ZIGEN assumes no responsibility for any inaccuracies that may be contained in this manual even if advised of the possibility of such damages The technical information contained herein regarding the features and specifications is subject to change without notice ZIIENCOFP COM Toll Free 877 650 5252 International 1 818 654 5252
8. e we are showing using an HDBaseT transmitter ZIG POEWP 100 connected to the HDBaseT receiver ZIG POE RXAV as mentioned previously you also get an amplified audio output for direct connection to speakers LAN ports for almost anything you choose and for controlling setting up the devices relays a 4K scaler and IR and RS232 control and functionality 1 Connect sources to POEWP HDMI and VGA w Audio 2 3 Connect Ethernet cable between HDBaseT transmitter ZIG POEWP 100 Connect RXAV to Display via HDMI and RXAV HDBaseT Ports this will also provide power on the ZIG POEWP 100 Connect LAN switch router to LAN 1 port this is the switch or router that issues IP address DHCP server Connect your PC or MAC to the same switch router The DHCP server will issue IP addresses to both devices separately Turn on the Source TV and RXAV Locate the serial number sticker on each RXAV and make note of it The web address for the given unit is http rxav xxxx where the xxxx are the last 4 digits of the serial number Ex If the serial number is 154320000015 then the web address is http rxav 0015 This is necessary to distinguish multiple units from colliding in the network before their names are changed by the customer The ZIG POEWP 100 operates similarly i e http poewp xxxx You can also locate the devices with Bonjour If you do need to connect directly from a PC or Mac to the LAN 1 or 2 por
9. in serial port and on to your projector TV 3 party controller etc for RS 232 device control 8 ZIG POE RXAV USER MANUAL ZIGEN 5 IR Receiver built in IR receiver sensor if possible place in line of site to remote control You can also use 3 5mm or locking connections for IR receiver 6 Status Indicator Lights a Power Solid green indicated power is present b Mode Should be flashing green data is flowing c Link Should be solid when TX and RX are connected d HDCP Solid Green when HDCP is detected present ZIIENCOFP COM Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Left Side Panel See items 1 6 on next few pages amp __ZIG POE RXAV HDMI Extender Scaler www ZigenCorp com 10 ZIG POE RXAV USER MANUAL ZIGEN Left Side Panel 1 2 LAN Connections Full Duplex Ethernet ports 10 100 BaseT Use for programming the ZIG POE RXAV and ZIG POEWP 100 or for 3 party controller or connection to your ISP or router 2 IR connection terminal 5 pin locking Phoenix style connector a IR OUT b IR OUT c Ground d 12V e IR IN 3 12V 3 IR connection via 3 5mm a IR OUT Use mono plug tip amp ring P and P b IR IN Use stereo plug tip ring amp sleeve Signal 5V amp Ground Note Includes dual voltage IR that installers can use to power up any 3rd party IR receiver such as Xantec KX AV or Niles Traditional extenders
10. is is what you want to call the unit syntax example CR100RX_k123 This is also the name you type into your browser to access the WebOS e Erase Storage will erase user entered date like installer notes e Choose File Upload Firmware when necessary this is where you select a new firmware file and upload firmware e Reset POEWP will reset the ZIG POEWP 100 remotely e Install Update when necessary is for installing new software updates to the unit RS 232 Commands ZIIENCOFP COM Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Command Structure ZIG POE RXAV RS232 commands lt hostname gt lt sp gt lt command gt lt sp gt lt parameter gt lt end of command gt lt hostname gt indicates the specific target RXAV device preceded by lt sp gt whitespace space or tab lt command gt defines the current operation lt parameter gt is the variable or the value passed to the device lt end of command gt newline char n ASCII OxA hex Response Structure lt hostname gt lt sp gt lt parameter gt lt sp gt lt parameter gt lt sp gt lt end of response gt lt hostname gt indicates the device initiating the response lt sp gt space ASCII 0x20 lt parameter gt command specific number of parameters each followed by a space 0x20 hex lt end of response gt newline char n ASCII OxA hex RS232 Protocol Settings Baud Rate 115200 Data Bits 8 Parity None Stop Bit
11. mitter Works especially well with Zigen ZIG PS 61 presentation switch and ZIG POEWP 100 wall plate transmitter 6 ZIG POE RXAV USER MANUAL ZIGEN Right Side Panel See items 1 6 on next few pages gt ZIGEN w ZIG POE RXAV HDMI Extender Scaler IR OUT GEN 12V IR IN 3 12V 3 5mm IR plug in configuration P P qro CI IR OUT SIG 5V GND EP www ZigenCorp com m lt P Zigencorp com Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Panel Description Right Side Panel 1 Speaker connection 4 pin female locking connector Connect directly to speaker wires and then to speakers Output is 20 watts per channel plenty or sound for classroom bedroom conference room or huddle room Dip Switch Dip Switch Settings Default Factory All Up or OFF Up Off Down On DIP 1 EDID OFF EDID default mode use EDID from connected TV ON Custom EDID not implemented yet Once implemented will override switches 2 and 3 DIP2 Force 3D Off OFF EDID copied from HDMI output ON EDID copied but force output to NO 3D DIP3 Force 2 Channel Audio OFF EDID copied normal with multichannel audio ON EDID forced 2 channel stereo DIP4 Audio Routing OFF Speaker output amp turned on ON HDMI output to TV amp turned off HDMI Output Connect HDMI cable here for output to the display or projector RS 232 Connect to standard 9 p
12. ponse rxav 01 pwr x Warranty Information 22 ZIG POE RXAV USER MANUAL ZIGEN LIMITED WARRANTY with the exceptions noted in the next paragraph ZIGEN warrants the original purchaser that the equipment it manufactures or sells will be free from defects in materials and workmanship for a period of three years from the date of purchase The proof of sale is required in order to claim warranty Should this product in ZIGEN s opinion prove defective within this warranty period ZIGEN at its option will repair or replace this product without charge Customers outside of US are responsible for shipping charges to and from ZIGEN Any defective parts replaced become the property of ZIGEN This warranty does not apply to those products which have been damaged due to accident unauthorized alterations improper repair modifications inadequate maintenance and care or use in any manner for which the product was not originally intended for Items integrated into ZIGEN products that are made by other manufacturers notably computer hard drives and liquid crystal display panels are limited to the term of the warranty offered by the respective manufacturers Such specific warranties are available upon request to ZIGEN ZIGEN makes no other representation of warranty as to fitness for the purpose or merchantability or otherwise in respect of any of the products sold The liability of ZIGEN with respect to any defective products will be limited to th
13. t in the RXAV without a router LAN you can expect up to 5 minutes for the address to be resolved Once connected the user interfaces will be available for you to evaluate change enter commands etc zigencorp com Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN ZIG RXAV POE Remote Control ZIGEN VOLUME a 8 gt m v m gt Perfect for classrooms when connected to the ZIG POEWP 100 use the remote to change between HDMI and VGA sources e Trigger devices connected to relays e Mute the audio e Power down the RXAV e Control the Volume 16 ZIG POE RXAV USER MANUAL ZIGEN WebOS Interface Page ZIG POE RXAV ZIGEN ZIG POE RXAV Control Panel Local HDBaseT Remote HDBaseT LINK LINK HDMI HDMI Mode Mode Status Cable Length 31 Cable Length 32 Refresh Device Name rxav Notes installer notes for rxav Control Defaults Control Device Name Notes IP Address 172 31 31 76 Firmware Res et Hostname xav Change Name Erase Storage Info Choose Files no files selected Upload Firmware Reset POEWP Install Update WebOS zigencorp com Toll Free 877 650 5252 International 1 818 654 5252 ZIGEN Status Local HDBaseT RXAV in this case Link Green when there is an HDBaseT connection HDMI Green when HDMI is present Mode Solid green when HDCP is present flashing green when no HDCP detected Cable
14. ting to speakers Right Speaker Right Speaker Left Speaker Right Speaker 14 gauge and higher speaker wire pin outs are labeled on unit 5 Pin connector for IR connecting block IR OUT IR OUT Ground 12V IR IN 3 12V Note connections also labeled on top of unit Consult you IR device manufacturer for proper connections zigencorp com Toll Free 877 650 5252 International 1 818 654 5252 zen ER Auto Switching de Pr al ik AK UHD L 4K Scaler Webos N 20W Audio P Relays IP 47 si amp a oo ZIG POEWP 100 192 168 1 100 me a e gt ow ow _ FR 4 ws T y Up To 328 Single J t CAT5e og e E ey The ZIG POEWP 100 can be used stand alone as an HDBaseT wallplate transmitter but really m shines when paired with the ZIG POE RXAV HD receiver amp scaler amp audio amplifier A perfect no control control system using mr HDBaseT on connection technology to fire up projectors drop screens and control lighting in small rooms BYOD and in seconds collaborate with your colleagues with full audio and video in stunning 4K UHD A must for conference rooms and huddle spaces 10 100 BaseT Ethernet ZIGEN ZIG POE RXAV 192 168 1 101 G amp G ZIGEN x ZIG POE RXAV HDMI Extender Scaler Internet Access Point 192 168 1 110 14 ZIG POE RXAV USER MANUAL ZIGEN General In the example abov

Download Pdf Manuals

image

Related Search

Related Contents

RS4soft - Safety Camp  COLORado 1-Quad IP Quick Reference Guide Rev. 6 Multi  Installation/Connection Manual Manual de instalación/conexión  CastoTIG 1501  5 to 15 m3/h - Hayward Pool Europe  Informations pratiques  Samsung BD-F5500E Manual de Usuario  RNA Clean-Up and Concentration Micro  Levapelucchi  