GSM DOOR INTERCOM SYSTEM (Up to 50 call
Contents
1. gt 6119 619 t 927 635 E 0129 p 920 36 L L 13 627 829 37 0149 1 2 309 938 P P L 15 23 F 1 939 M 169 24 32 40 Button module notes If the GSM module has 1 button the additional button module buttons should be addressed beginning with 2 i e The first button of the button module should be connected between a amp 2 the next between a amp 3 etc If the GSM module has 2 buttons the additional button module buttons should be addressed beginning with 3 i e The first button of the button module should be connected between a amp 3 the next between a amp 4 etc If the GSM module has 4 buttons the additional button module buttons should be addressed beginning with 5 i e The first button of the button module should be connected between a amp 5 the next between a amp 6 etc PAGE 7 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VIDEX CODELOCK MODULE 4800 The 4800 codelock includes three relay outputs two push to exit button inputs and operates from a 12 24V ac dc power supply Up to 2 unique codes can be programmed each in the range of 4 8 digits Relay time can be programmed from 01 99 seconds or set to latching mode with a relay time of 00 To latch type in the code followed by Enter to unlatch type in the code followed by clear Art 4800 Connections Connection
2. Disable voicemail 1210 1760 Disable text alerts 148 1760 NOTE Disabling voicemail and text alerts is very important as there is no way to retrieve either of these services from an intercom panel Disabling these features will also prevent the intercom panel switching to voicemail or sending a text when dialling in from another phone STORE SMS AUXILIARY MESSAGE SMS When g amp 4 Auxiliary 2 input are shorted on the intercom panel a text message will be sent to the master telephone number The text message can be customised using the following message 1111SMS HouseAlarm Change message to HouseAlarm Note The message can be a maximum of 32 characters long and can not include spaces or PAGE 21 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX PROGRAM BY AT COMMANDS PRG This is an advanced feature of the system which can allow an AT format command to be sent to the OEM GSM module 1111PRG command Send an AT command to the OEM module STORE CREDIT BALANCE CHECK STRING SDL Several network providers offer the facility to check available balance on their pay as you go tariffs For example on Vodafone the string is 1345 and on the string is 10 Other networks may also have this feature Because the intercom will not know the details of the network provider s SIM card which you have inserted it will be necessary to store the correct string in order to use the credit balance check fe
3. RX VIDEX GSM INTERCO CE X File Data About MAIN SETTINGS CALL SETUP DIAL TO OPEN Times General Settings 1111 Call Time Master Code Relay Time 2 Balance Check String 13458 Auto Dial Days 5 Master Telephone No 07774949815 Modes AUX2 Message Aux Triggered Aux Mode On When Triggered w Enabled extended diverts Enabled silent dialling Speaker Volume Time Bands Microphone Volume The general settings page has the following programmable options Call Time Maximum length of a call before it automatically clear down 20 240 Seconds Relay Time Relay activation time 0 99 Seconds 0 latching Auxiliary output AO terminal switched OV time 0 99 Seconds 0 latching Only relevant for Aux mode On when triggered The time a phone is allowed to ring before the unit cancels the call and diverts to the second number of programmed 15 99 seconds Auto Dial Days Number of days the unit will wait with out a call being made before it makes a short call to keep the system live and on the network 1 99 days Aux Mode The AO terminal is a switch OV output It can be programmed to trigger by the end user pressing 6 on their telephone during a call or can be setup to switch on when a call is made and stay on for the length of the call Additionally this output can be set for use with a status indicator or as a switch to transfer calls to the master number The four options a
4. Funcdion J C2 Normally closed connection of relay 2 Dry contact Common connection of relay 3 Dry contact Normally open connection of relay 3 Dry contact Push to exit input for relay 1 Triggered by OV Push to exit input for relay 2 Triggered by OV c e a4 T ART 4810N 12 ay OV AO Lise either MO or NC Helease Dry contact output Remember to sH codalnck may tz l shorber irme thal hal of tha 4810M relay Ema PAGE 8 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX ART 4800 CODELOCK INITIAL PROGRAMMING All programming is carried out using the codelock keypad The programming menu is protected by an engineer s code The factory default engineers code is 111111 6x1 This code can be changed to any four to eight digit code during the program but must be different to the codes used to gain entry Follow the flow chart to setup the system Enter the engineers code 111111 Then press enter Enter a new engineers code or enter the same engineers code again followed by enter Enter the access code for relay 1 and then press enter Enter a two digit relay 1 time from 00 99 and then press enter More codes NO YES Enter the access code for relay 2 and then press enter Enter a two digit relay 2 time from 00 99 and then press enter More codes Enter the access code for relay 3 and then press enter En
5. 16 06 2011 GSM 1 0 4 Added the following new facilities 1 Lost connection recovery routine to dial divert number if no carrier detected on primary number Time band added to disable divert call buttons to the master telephone number 3 Time Date check facility via SMS 2 new modes of operation for the AO terminal to allow the following new functions Optionally divert calls to the master number Check the status of a door gate Improved speech volumes Allow silent dialling feature Extended diverts feature PAGE 39 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 Northern Office Videx Security Ltd Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London 4 8TD FAX 0208 523 5825 TECHNICAL SUPPORT tech videx security com TEL 0191 224 3174 FAX 0191 224 4938 http www videx security com PAGE 40 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5
6. need to call and can also give you an indication of functions available as identified in the back of this manual Communication port setup Although the communication should setup Ao Detect automatically when the program is started it is also possible to manual setup the communication port Communication Port Setup _ To setup manually first press the Refresh List button which will find all available communication ports Then either select from the drop down list the port which is connected to the GSM unit and press the Auto Detect button to check for the device or just simply click on the Auto Detect button to check all available ports If the device is found the status will change to online Detect Mobile phone The mobile phone can be used like a normal mobile phone to make calls This can be useful when setting up the GSM unit s SIM card with functions such as switching off voice mail and text alert or listening to the SIM cards balance through the intercom s speaker Simply type the number to call on the keypad and click the send button Ti end the call press the W button and to clear the display press the C button Please note After making any changes to the settings and stored telephone numbers on the PC they must then be uploaded to the unit before they will take affect PAGE 25 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 GENERAL SETTINGS
7. nnn 001 250 A text message will be sent to the sender with the stored number for that location 1111STRnnn Delete the telephone number stored in location nnn where nnn 001 250 1111S TRnnn Delete and confirm deletion of a telephone number in location nnn where nnn 001 250 Note It is important to switch off voicemail and automatic SMS features on the SIM card when using this feature See the Forced Dial section for more details Also note that it will not be possible to use the dial in to speak facility from a number stored to release the door gate when dialling in Door release takes priority SET CALL TIME SPT The call time is the maximum time in seconds that a call can last before the intercom panel automatically clears the call down The time can be from 20 seconds up to 240 seconds 4 minutes and begins from when the call button is pressed The default time is 40 seconds The following messages are used to set check the maximum call time 1111SPTnn Store the time nn x 20 seconds e g nn 03 time 60 seconds 1111SPTnn Store the time nn x 20 seconds e g nn 02 time 40 seconds Also send a confirmation text back to the sender 1111SPT Query the current stored time A text message will be sent to the sender showing the stored time Remember to multiple the number in the received text by 20 seconds SET RELAY TIME RLT The relay time can be from 01 99 seconds or latching
8. or delete telephone numbers If you have a large number of buttons or telephone numbers to enter you may find programming easier with the PC software Simply send texts in the format below to the telephone number of the SIM within the intercom panel lt 4 DIGIT CODE gt lt 3 DIGIT FUNCTION CODE gt lt OPTIONAL DATA gt lt OPTIONAL gt 4 DIGIT CODE The code prevents unauthorised access to the programmable features of the system The code must be four digits long but can be any combination using digits 0 9 The default code is 1111 and will be used for all examples in this manual 3 DIGIT FUNCTION CODE The 3 digit function code identifies the programmable feature to be changed The code must be in capital letters The table below lists the available codes DESCRIPTION CODE EXAMPLE SETTINGS DEFAULT PAGE 1111STDnnn 01912241559 Set aun out mode m 990 Keep conection Hob iuo m 01 99 a ane 1111DLE 123 1111SMS HouseAlarm 11115DL 413454 1111BAL 1111STM 07771234567 1111TBA 06002300 OPTIONAL DATA The optional data will vary depending on the command used It may be a telephone number a time setting or may not be used at all For more information see the command settings below PAGE 17 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX OPTIONAL Most of the commands support the feature When this is added to the end of the text messag
9. programming Power up initialisation sequence 2 short beeps Approx 15 seconds delay 1 short beep Approx 15 seconds delay One short beep System is ready RESET TO FACTORY DEFAULTS There are two reset modes available The first will reset the master code only and the second will reset everything and clear all stored telephone numbers RESET THE MASTER CODE TO 1111 1 Power down the intercom panel 2 Put a short across terminals g amp 7 3 Power up 2 beeps will be heard followed by a delay and then a further beep 4 Remove the short after the 3rd beep 5 The master code is now reset to 1111 FULL RESET Power down the intercom panel Put a short across terminals g amp 8 Power up 2 beeps will be heard followed by a delay and then a further 2 beeps Remove the short after the 4 beep All settings are returned to factory defaults PROGRAMMING Programming can be carried out either by text message or by PC lt lt lt lt o IMPORTANT NOTE When you are required to use in a text message it is very important to use the correct symbol and not for example Or two single apostrophes side by side which you will see look the same but will be interoperated differently by the SMS intercom panel PAGE 16 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX PROGRAMMING BY TEXT MESSAGE Programming by text message is a simple way to customise the settings of the intercom panel and add
10. stop time 1111TBA HHMMHHMM otore the time using this format The first HHMM is the start time to receive calls i e 0600 for 6am and the second HHMM is the time to stop receiving calls i e 2330 for 11 30 at night 1111TBA HHMMHHMM As above but also reply with a SMS text back to the sender with the stored setting PAGE 22 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 1111TBA Query setting A text message will be sent to the sender with the stored time window 1111 Delete the time band and allow calls to be received at any time 1111TBA Delete and confirm deletion of the time band ENABLING DISABLING SILENT DIALLING When the intercom is calling the telephone number there is a choice of either hearing the ringing noise from the intercom or just hearing beeps to indicate calling Ringing heard during calling nn 01 Beeps heard during calling nn 00 1111AUEnn Store the mode nn 00 or 01 1111AUEnn Store the mode nn 00 or 01 Also send a confirmation text back to the sender 1111AUE Query the current stored mode A text message will be sent to the sender showing the stored mode ENABLING DISABLING ADDITIONAL DIVERTS The default for diverts is that each of the 50 call buttons can have one divert number If the additional diverts facility is activated it will be possible to have up to 5 divert numbers but the system will then be limited to 10 call buttons Standard divert to only on
11. stored the first number will continue to ring until the call times out File Data About DIAL TO OPEN It is possible to store up to 250 woexcsminterco telephone numbers which will activate the relay when they call I the GSM The GSM unit will I drop the call so there will be no i decenas charge for these calls In the table it is possible to assign a telephone number and a name to each of the 250 possible locations Please note the name is only for convenience and is not uploaded to the GSM x Note Name is not uploaded to the intercom unit 158 FILE MENU From the file menu it is possible to create a new data file open an existing data file and save the current data file These options are available online or offline allowing the data file to be created on or off site for convenience The exit option will close the program PAGE 27 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VIDEX GSM INTERCON About Upload Upload All Download Upload Settings Signal Strength Upload Calls zl VIDEX GSM INTERCON Upload Dial To Opens MAIN Upload gt IP DIAL TO OPEN Signal Strength Download Settings Download Calls Download Dial To Opens PC Requirements Windows XP Service Pack 3 or Later Net framework 4 or later CD Drive USB port Download A N VIDEX Data MENU The data menu is only
12. your start menu as Videx GSM Before running the program connect the supplied USB cable between a USB port on your PC and the GSM unit Run the program and the following screen should appear PE VIDEX GSM INTERCOM jene nnd File Data Check Ferrea FUNE GSM fue Detect VX s VIDEX QM LIME Yde deee found and online When the program loads it checks all available ports for the GSM unit If found the GSM unit goes online with the PC From the main screen it is possible to Signal Strength Check signal strength Click on update to retrieve the signal strength from the unit The signal dd strength will be between 1 amp 31 whereby 31 is excellent and 1 is poor A signal strength of at least 10 is required for the system to work Good 18 satisfactorily 54 80 Check balance on pay as you go SIM s wass For this to work you must first store the check string required by the service provider on the settings page For example the string 1345 is used by Vodafone to retrieve your current balance Once this has been stored and uploaded to the unit clicking the Check Balance button will retrieve it VER 1 0 2 Check Firmware PAGE 24 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX Check firmware version Click the Check Firmware button to retrieve the firmware version of the GSM unit This will be useful to technical support should you
13. CHNICAL MANUAL VER 2 0 5 MX _ VIDEX CHECKING THE BALANCE BAL Note The balance can only be checked if the correct balance check string has previously been stored using the SDL code explained earlier in the manual The intercom also has the facility to monitor the available credit and then text you to inform you when it has fell below 5 00 5 00 or 5 00 It will then remind you with another text after every 5 calls until the credit is either increased or it runs out To use this feature the following settings must first be made o You must be using a Pay AS You GO SIM card from a provider that offers this service Vodafone o The correct balance check string must be stored using the SDL code o Amobile phone number in which to receive the balance low text must be stored in the master telephone number location using the STM code UNDERSTANDING THE SIGNAL STRENGTH SIG When a request for signal strength message is sent to the intercom panel it will reply with a two digit signal strength code The code will be between 0 31 or 99 Ideally the signal strength should be as close to 31 as possible The lower the number the weaker the signal Signal strengths lower than 10 may cause operational problems such as loss of speech quality and possibly missing DTMF tones and network loss A signal strength of 99 indicates it could not be detected DIALLING INTO THE INTERCOM FROM ANOTHER TELEPHONE There are three possible outco
14. DISABLED FACILITY see 14 CABLE SIZE GUIDE ttes 15 INSTALLATION RAMRRRRMMRMMMMMMMMMEKKFER RHNMMWMMMMMMMMMMMMMMMMMMMMMMMMMMM 15 PANEL CARE RM 15 TESTING POWER UP AND RESET ttt tti 16 RESET TO FACTORY DEFAULTS eet ld 16 PROGRAMMING e 16 PROGRAMMING BY TEXT MESSAGE rettet rts 17 STORING THE CALL BUTTON TELEPHONE NUMBERS STN STD iieii 18 STORING A TELEPHONE NUMBER FOR DIAL IN DOOR RELEASE 18 SET CALL TIME SPT cccccecsecsesscsecsecsessesecsucseceesecsecsesacsucsucsessesansussussesuesacsucsessesatsucsessesatsatsessasetsatssseseeeses 19 SET RELAY TIME 19 SET AO AUXILIARY OUTPUT TIME FOR AOM 01 ONLY AOT isisisi 20 SET AO AUXILIARY OUTPUT MODE AOM c sccsecscssssecsessececssesecsessesecsrssessesecsuesssesetsesstsstsseseeseseeeee 20 CHANGING THE FOUR DIGIT CODE 20 SET DAYS TO WAIT BEFORE MAKING A CALL 20 DIVERT TIME DIT cccessccsecsececsecsecseseesecsecsesecsuceessessesussucssessucsusaucsesetsussussesetsusarsetsstsststsetssitstsatssatseeeeeeees 21 FORCED DIAL 21 STORE SMS AUXILIARY MESSAGE SMS 21 PROGRAM BY AT COMMANDS 22 STORE CREDIT BALANCE CHECK STRING SDL sse 22 STORE THE MASTER TELEPHONE NUMBER STM street 22 STORE THE TIME BAND 22 ENABLING DISABLING SILENT DIALLING cte 23 ENAB
15. GSM DOOR INTERCOM SYSTEM Up to 50 call buttons TECHNICAL MANUAL EDITION 2 0 5 VX VIDEX PAGE 2 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 CONTENTS MANUAL INTRODUCTION DA 4 SYSTEM INTRODUCTION ccccccccsessecsessesecsucseceesecsucsecsesecsussussssesucsucsusssetsussucseseesatsussesatsusstsstestssesetstsstseeseee 4 PRECAUTIONARY ADVICE cccccessessessessesecsessesecsuesscsesscsucsussuseesucsussussesecsussncsssesstsassuesesstsassusstsatsetsatstsaeeeeeees 5 SYSTEM 2 6 INTERCOM o0 RM 6 EXTENSION BUTTON MODULES ccccessessessessesscsecsessesecsscscsecsussucsesecsucsussessesucsussusseseesucsusecsatsnsateeesseseeee 7 CODELOCK MODULE 4800 tret ttt tete 8 ART 4800 CODELOCK INITIAL PROGRAMMING cccccssessessesecseceesseseesucsessessesutsucstssesetsetstsstsetetseteseeeee 9 ART 4800 CODELOCK REPROGRAMMING GUIDE cete 10 DOOR PANEL MOUNTING FRAMES teet 11 POWER SUPPLY cccccsccccsscsecsecoesscsecseceesuesecsucsessesucsucsecsesucsussecsesatsucsucsessesaesuesecsesatsaessersatsatsetstssesestsessesseseee 11 WIRING DIAGRAMS se ettet tert ertt EEA LE EEEE ttt ons 12 PUSH TO EXIT BUTTON AND AUXILIARY INPUTS OUTPUTS see eee 13 STATUS INDICATION INPUT ccscccecsescsecsessessesecsucsesscsucsucsesscsussucsucsesacsussussessesetsusssstsasstsstssesateresitstseteeeseee 14 ALL CALLS DIVERT FACILITY AND CALL BUTTONS
16. LING DISABLING ADDITIONAL DIVERTS ceee teet 23 PROGRAMMING BY PC aan ertt ttr rtt sns DD 24 SYSTEM OPERATION I a ttt trt tert rtt todos DD 29 USER COMMANDS sccscsscsscsessessesucsscsececsecsucsesecsucsuessssesussussusessecsussussesetsuseesatsatsusstssesatsusstesnestssesetstseteeeseee 29 CHECKING THE BALANCE BAL 30 UNDERSTANDING THE SIGNAL STRENGTH SIG 30 DIALLING INTO THE INTERCOM FROM ANOTHER 30 RECORD SHEET cccccseccecsesscsecsessessesecsucseceesucsucsesuesucsucsesstsucsucssetsucsucsucsesaesucsessesatsessessesatsaesiesessessestsisseseesees 31 DIAL IN ACCESS CONTROL MEMORY RECORD SHEET 33 UNDERSTANDING THE BEEPS II n nn teet ttt dec 36 TROUBLE SHOOTING ttt trt rtt 37 PAGE 3 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX MANUAL INTRODUCTION The information in this manual is intended as an installation and commissioning guide for the GSM door intercom system This manual should be read carefully before the installation commences Any damage caused to the equipment due to faulty installations where the information in this manual has not been followed is not the responsibility of Videx Security Ltd VIDEX run free training courses for engineers who have not installed this system before Technical help is also available on 0191 224 3174 during office hours or via e mail tech videx security com SYSTEM I
17. NOO0 Button 40 Divert STDO400 4 41 SITNOM 4 Button 41 Divert STDO0M 4 Buton42 STNO2 Button 42 Divet STD0442 4 43 STNO33 4 Button 43 Divet STDO0433 4 Butond4 STNO4M J 4 Button 44 Divert 57004 45 STNO45 J Button 45 Divet 570045 4 46 STNO6 Button 46 Divert STDO46 J 4 Buton47 STNO7 O 4 Button 47 Divert STDO7 4 Butond8 STNM8 J Button 48 Divet STDO8 4 Buton49 STNO49 Button 49 Divert STDO4499 4 Button50 STNOO0 4 Button 50 Divert STDO0 4 PAGE 32 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 DIAL INACCESS CONTROL MEMORY RECORD SHEET PAGE 33 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 PAGE 34 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 PAGE 35 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX UNDERSTANDING THE BEEPS Functions and errors are indicated by beeps from the intercom panel The following will help you unde
18. NTRODUCTION The system is designed to work on the same technology as mobile phones It enables a call to be made from an entry point Door gate etc to any telephone number mobile or land line Up to 50 call buttons can be connected to the door panel each able to call two telephone numbers If the first is busy or not answered the call can be diverted to the second or with the additional divert facility enabled it is possible to have up to 10 call buttons each with 1 primary number and 5 divert numbers Features of the system include a dry contact relay output an open collector auxiliary output push to exit input and switched OV auxiliary input Programming of the telephone numbers and additional features can be carried out via text messaging or PC using a specially designed Windows program An additional access control feature for up to 250 telephone numbers is also available on the system allowing a number of callers to open the gate door simply by dialling the telephone number of the intercom panel The intercom panel will not answer these calls but will activate the relay output A SIM card is required for this product but not supplied It is recommended to choose the SIM card which has the best coverage for the area in which the intercom panel will be installed Both contract and as you go SIM cards be used but if using a Pay as you go we would recommend setting up an automatic top up to avoid running short on credit an
19. STER TELEPHONE No BUTTON MEM LOCATION USERNAME TELEPHONENo Button SN j Button 1 Divert STDO1 G Buton2 X STNO2 J J Button 2 Divet 1 5002 d Buton3 STNOS3 s j g Button 3 1 STDOO3 s J Butond 4 STNO4 JJ Button 4 Divet STDOO4 9 Button5 X STNOS 2 e Button 5 Divet 5005 J 9 Buton X STNOG G Button 6 1 STDOO6 09 39 Button7 STNOT mJ v Button 7 Divet 1 STDOO7 Button8g X STNOB J J J 25 Button 8 Divert STD0B J Button9 STNO9 J jJ 3 25 Button 9 Divert 1 STD0O9 Button fO _ STNOO m Button 10 Divert STDO0100 p Butonf STON Button 11 Divet 5001 0 Buton2
20. STNO2 Button 12 Divert STDO12 S o Button13 Button 13 Divert STDO1B pButton 14 STNO4A j b Button 14 Divert STDO014A JJ pButton15 STNOI5 J s 25 Button 15 Divert STD015 __ J Button 6 PS 2 4 Button 16 Divert STDO016 JJ Button 17 STNOI7 Button 17 Divet STDOt7 G Button18 STNOIBB J 4 9 Button 18 Divert STD018 S Button19 STNOIO G Button 19 Divert STDO19 000 0 Button20 STNOO J 9 Button 20 Divert _ STDO20 s nm Button21 4 STNOT LJ Button 21 Divert STD0O21 J Buton22 STNO2 s s 25J Button 22 Divert STDO22 PP Button23 1 STNO3 J 9 2 25 Button 23 Divert STDO23 PP Button24 X STNO4M 3 2 2 Button 24 Divert STD024 lll j PAGE 31 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL
21. Set the relay time to 00 for latched mode In latch mode the relay will stay energised until the command is send again 1111RLTnn Store the time nn time in seconds 1111RLTnn Store the time nn time in seconds Also send a confirmation text back to the sender 1111RLT Query the current stored time A text message will be sent to the sender showing the stored time PAGE 19 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 SET AO AUXILIARY OUTPUT TIME FOR AOM 01 ONLY The AO time can be from 01 99 seconds or latching Set the AO time to 00 for latched mode This option is only relevant for aux mode 01 1111 Store the time nn time in seconds 1111AO0Tnn Store the time nn time in seconds Also send a confirmation text back to the sender 1111 Query the current stored time A text message will be sent to the sender showing the stored time SET AO AUXILIARY OUTPUT MODE AOM There are four modes of operation for the AO terminal User activated nn 01 To activate the AO terminal either short g to 5 Auxiliary 1 input or press 6 on the telephone during a call Call activated nn 00 AO will activate when a call begins and deactivate when the call ends Used for status indication nn 02 When in this mode the AO terminal is used exclusively for monitoring the status of an input For example checking if a gate door is open of closed Divert calls to master number
22. VER 2 0 5 Buton25 STNO2 Button 25 Divert STD02 OSOS Buton20 STNO260 Button 26 Divert STDO260 ese OSOS Button27 SN 4 Button 27 Divert STDO277 4 Button28 SN J 4 Button 28 Divert STDO28 OSOS Button29 SIN 4 Button 29 Divet STDO29 Button30 STNOO0 J Button 30 Divert STDOS30 Buton31 STNOM J Button 31 Divet STDO3M 32 STNO32 Button 32 Divet STDO322 4 Button33 SN J Button 33 Divet STDO33 Buton34 STNOM J Button 34 Divert STDO34 35 STNO5 O Button35 Divert STDO355 J Buton36 STNO60 O Button 36 Divert STDO300 Buton3z STNOYV J 4 Button 37 Divert STDO37 J Buton38 STNOB8 O Button38 Divert STDO388 Button39 STNO99 Button 39 Divet STDO399 Butond0 ST
23. atures 1111SDL 1345 Store the balance check string for a Vodafone pay as you go 1111SDL 10 Store the balance check string for an O pay as you go STORE THE MASTER TELEPHONE NUMBER STM The master telephone number is the number which will receive automatic balance updates when the balance gets low If this feature is setup and will receive the SMS message if the auxiliary 2 input is triggered To store this number 11119 TM yyyyyyyyyyy Store the telephone number yyyyyyyyyyy 11119 TM yyyyyyyyyyy Store the telephone number yyyyyyyyyyy and send a confirmation text message to confirm storage of new number 1111STM Query the telephone number stored A text message will be sent to the sender with the stored number for that location 11119TM Delete the telephone number stored 11119TM Delete and confirm deletion of a telephone number The master telephone number is the number which will receive automatic balance updates when the balance gets low If this feature is setup and will receive the SMS message if the auxiliary 2 input is triggered To store this number STORE THE TIME BAND TBA The time band feature allows the call buttons to be disabled or diverted to the master number outside a certain time window For example if the tenant only wants to receive calls between the hours of 6 00 in the morning until 23 30 at night Remember to always use the 24hr clock and also ensure the start time is earlier than the
24. available when online From here it is possible to upload the information from the PC to the GSM unit and download information from the GSM unit to the PC Both upload and download have several options which include facility to upload download all data or upload download only a section of data which is required and has been changed PAGE 28 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX SYSTEM OPERATION TO MAKE A CALL FROM THE INTERCOM PANEL Press the required call button Two beeps will be heard to indicate the call has been placed If a mistake is made press any other button to clear the call A long beep followed by a short beep will be heard to confirm the call has been cleared Note If the same button is pressed after five seconds of placing the call this will also clear the call down Pressing the same button before five seconds will do nothing DOOR GATE RELEASE This is signalled by 1 second interval beeps from the intercom panel Pressing 3 releases the door gate for the programmed time Pressing 1 followed by 0 will latch the door gate in the open position Note To unlatch press 3 the door gate will unlatch after the programmed time RELEASING THE GATE DOOR BY DIALLING THE INTERCOM PANEL NUMBER This feature is only possible if the caller s number has been stored correctly for this feature Simply dial the number of the intercom panel The intercom panel will drop the call and then open the gate door
25. casions to prevent dirt build up and tarnishing of the metal A general household metal polish can be used but care should be taken to follow the grain of the metal when polishing and also avoid any polish build up around the call buttons which may prevent the buttons from operating correctly PAGE 15 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX TESTING POWER UP AND RESET After connecting the power supply antenna lock output and auxiliary devices as shown in this manual and before powering up a SIM card must be installed The SIM holder can be found on the back of the module under the label SIM A SIM card from any supplier can be used Simply push the SIM card in It will only fit one way IMPORTANT Replace the label over the SIM hole Check all the connections have been made correctly and then power up the system The GSM intercom requires approximately 30 seconds too initialise properly We recommend not sending SMS messages or pressing buttons during this time From power up two short beeps will be heard and then following a short delay of approximately 15 seconds a further short beep will be heard After approximately another 15 seconds another short beep will be heard The module is now fully initialised Note If you here a different combination of beeps in place of the last short single beep then you can find the meaning of these beeps towards the back of this manual Once initialised you can begin
26. ch the relay when the code is entered and require the code followed by clear to unlatch The red LED will go off to confirm the exit from programming mode VER 2 0 5 VX VIDEX ART 4800 CODELOCK REPROGRAMMING GUIDE Enter the Engineers code Relay 1 code engineer s NENNEN code Relay2code Relay3code Press Enter RED Light will illuminate Relay 1 Time MEER Relay 2 Time Re Enterthe Alternatively enter a Relay 3 Time Sy engineer s new engineer s code code 4 8 digits Press Enter Enter relay Relay code 4 8 code digits operates the door or gate Press Enter Two digits 01 99 Sec time or 00 for remain open Press Enter Press Enter RED Light will twice to exit switch off programming Repeat steps 4 forrelay2 amp relay 3 Notes If the red light does not illuminate the engineers code is incorrect Follow the factory default procedure below On the first loop of the flow chart its relay 1 second loop is relay 2 FACTORY DEFAULT PROCEDURE Step 1 Remove the power from the keypad Step 2 Press and hold the enter button while re powering the keypad Step 3 Release the enter button The factory engineer s code is restored to 111111 6 x 1 PAGE 10 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 MX VIDEX DOOR PANEL MOUNTING FRAMES Both surface and flush mounting frames are available The size of the frame will depend on the
27. d feeds back Try lowering the speaker volume using jumpers JP2 amp JP3 Try adjusting the volume using the programmable settings during a call Check the microphone is fitted correctly in the intercom panel and that the mic hole is not blocked in any way E E ERROR message returned in SMS when Check over the message sent again and compare it with i h les in th programming or no SMS returned at all exampes the manua Common errors include even though a was included at the end of the message sent 1 Using two apostrophe marks side by side instead of Note that these look the same in the message An easy way to see if this is the problem is to move the cursor along in the message and if the cursor can get between the two then it is not the connect character used 2 Lower case letters instead of upper case For example using stn when STN should be used PAGE 37 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX Enfora certifies that the Enfora Enabler TM MHz GSM Radio Module FCC ID MIVMLGO208 complies with the RF hazard requirements applicable to broadband PCS equipment operating under the authority of 47 CFR Part 22 or Part 24 Subpart E of the FCC Rules and Regulations This certificate is contingent upon installation operation and use of the Enabler IIG module and its host product in accordance with all instructions provided to both EOM and end used When installed and operated i
28. d loosing the use of the intercom panel Alternatively if you already have a contract mobile phone it should be possible to get a second SIM card and telephone number on the existing account For more information contact the SIM card provider or visit their web sites Network provider selection It is imperative for the reliably operation of the system that the best network provider for the area is selected Problems such as network disconnection can occur if the provider has signal or interference problems for that area We would recommend using a GSM signal strength meter to survey the intended antenna location Contact Videx for more information on where to purchase a tester As an initial check also go to www sitefinder ofcom org uk and enter the postcode of the intended installation This will show all transmitters in the area It is advised to choose the closest one or if there are many then choose a transmitter working on 900MHz as this frequency works best through obstacles such as walls buildings etc The antenna should always be mounted vertically at the highest point possible Metal structures and sources of interference such as power cables control panels etc can affect signals and so the antenna should be mounted away from these When registering a new SIM you may be asked for the IMEI number This is the unique serial number of the GSM intercom and can be found on the rear of the module just below the SIM holder on a white label It s th
29. e a confirmation text message will be sent back to the sender indicating the new data has been received and stored When sending text messages there may be a delay from when you send the message to when it is received by the intercom panel depending on how congested the network is If you are at the door panel when sending the message you will here a single beep from the intercom panel to indicate it has receive the message STORING THE CALL BUTTON TELEPHONE NUMBERS STN STD Telephone numbers can be stored for the 50 available call buttons Each call button can call up to two telephone numbers If the first is busy or not answered in a certain time it can call the second number if the divert facility is setup The STN code stores the first number called when the button is pressed and the STD code stores the diverted telephone number if the first is busy or not answered The messages to store check numbers are as follows Replace STN with STD when storing checking divert numbers 1111S TNnnn yyyyyyyyyyy Store the primary telephone number yyyyyyyyyyy in position nnn 1111STNnnn yyyyyyyyyyy Store the telephone number yyyyyyyyyyy in position nnn and send a confirmation text message to confirm storage of new number 1111STNnnn Query the telephone number stored in location nnn A text message will be sent to the sender with the stored number for that location 1111STNnnn Delete the telephone number stored in locatio
30. e long number below the barcode PAGE 4 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX PRECAUTIONARY ADVICE O When mounting the GSM antenna choose a location which is away from human interaction and away from the intercom panel Route the GSM antenna cable from the intercom panel so that it is separate from the power supply cables and microphone wire Always ensure the power is off to the intercom panel before inserting or removing the SIM card New SIM cards will need registering before they can be used Full details of how this is done can normally be found in the SIM card pack It will normally require that the SIM card is inserted into a mobile phone a number dialled and instructions followed While the SIM is in the mobile phone it would be a good time to disable any PIN codes call diverts ring back and disable features such as voicemail and text alerts Details of how to do this can be found on the SIM card providers web site or by calling their customer services Please use one of the following SIM card providers Vodafone TMobile O2 or Orange We do not recommend using 3 at this present time To be able to receive text messages from the intercom panel the SIM card will require an SMS service centre number This is normally preinstalled on new SIM cards but if you are having trouble receiving SMS messages you will need to confirm this by inserting the SIM card into a telephone and using the telephones menu o
31. e number nn 01 Extended divert to up to 5 numbers nn 00 1111EXDnn Store the mode nn 00 or 01 1111EXDnn Store the mode nn 00 or 01 Also send a confirmation text back to the sender 1111EXD Query the current stored mode A text message will be sent to the sender showing the stored mode When using extended divert mode use the following memory locations to store the numbers 6 X STNOOG STD0O6 STD016 STDO260 X STDO36 STDO46 8 STNOB8B STDOO X STDOi8 STDO28 STDO38 STDO48 9 STNOO9 X STD0O9 STDOi9 STDO29 570039 STDO49 STD020 STD030 PAGE 23 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX PROGRAMMING BY PC NOTE PC software kit sold separately Part No GSMPRO USB DRIVER IMPORTANT Before connecting the GSM unit to the PC and before installing the GSM PC program first install the driver for the USB adapter which can be found on the supplied CD in the following folder D FT232Driver CDM20814 exe Where D is the letter of your CD drive SOFTWARE SETUP Run the setup program setup exe from the CD Follow the on screen instructions to complete the setup Please note the PC must be Window XP PRO or later and have the NET 4 framework installed The NET 4 framework can be found on the CD or will be downloaded from the internet during install After completing the setup the program will be available from
32. for the programmed time USER COMMANDS The following commands can be carried out during a call Note Successful commands are signalled by two beeps from the telephone errors are signalled by four beeps FUNCTION TKEYTOPRSS 2 KEYTOPRESS C a a a ADJUST DOOR SPEECH VOLUME 4 039 0 Lowest 9 Highest p ADJUST PHONESPEECHVOLUVE 7 0 9 0 Lowest 9 Highest The following text messages can be sent while in standby Examples show code as 1111 A FUNCTION j AMESSAGETOSEND _ __ ed CHECK THESIGNALSTRENGTH 1118IG 0 E ee a OOOO OO CHECK THE AVAILABLE BALANCE j BAL cu U CHECK THE SOFTWARE VERSION VER RELEASE THE DOOR GATE 1111RLY Optional send if a confirmation is required ACTIVATE THE AUXILIARY OUTPUT 1111AUX Optional send if a confirmation is required LATCH THE RELAY 1111RLA Optional send if a confirmation is required UNLATCH THE RELAY 1111RUL Optional send if a confirmation is required LATCH THE AUXILIARY OUTPUT 1111ALA Optional send if a confirmation is required UNLATCH THE AUXILIARY OUTPUT 1111AUL Optional send if a confirmation is required ee CHECKINTERCOM TIME amp DATE UNAK e uu _ CHECK TIME BAND SETTING il1TBA p CHECKINPUTSTATUS wH PAGE 29 of 40 GSM DOOR INTERCOM TE
33. is of adequate voltage as show and the name plate back light of the module earlier in this manual and that the jumper JP1 is in the correct position Not additional button modules does not illuminate Try a full reset as shown earlier in the manual Powering up with C2 amp PTE shorted Try a different SIM card Intercom module may have a fault __ T A long beep is heard when press a button No telephone number setup for that button Check the programming Check the SIM card is fitted correctly ee ee The intercom panel does not respond to Check the SIM card has a SMS service centre number SMS messages stored This will require putting the SIM card into a mobile phone to check Contact the SIM card provider if you are not sure Check the number you are sending the message to is correct The number of the SIM card in the intercom panel After sending a SM to the intercom panel Listen for a single short beep from the Intercom panel This will indicate that the message was received and understood If a long beep is heard it indicates the message was either not understood or the 4 digit code was incorrect Try resetting the 4 digit code to 1111 as shown earlier in this manual Powering up with C1 amp PTE shorted ee The call keeps dropping out Increase the call time in programming Check the signal strength and if necessary move or change the antenna or try a different SIM card provider Speech echoes an
34. mary one This may result in higher call charges Try another SIM provider for that area single short beep every 10 Unable to see the SIM card Check the SIM card is fitted seconds after power up correctly Try removing the Slm card cleaning and fitting again Try a different SIM card Short beep long beep repeated 3 Call button pressed and either the This may be the required setup times call is on divert to master or it is but if it s not then either change outside the time set in the time the time band times store a band and there is no master master number to divert the calls number stored to or open the switch between AO amp G used to switch the calls into divert mode Four long beeps Not registered with a network provider but still trying PAGE 36 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX TROUBLE SHOOTING SYMPTOM TEST Interference on the speech Check the signal strength 1111SIG If the signal strength is to low the GSM module which increase its power to compensate causing interference with the speech circuits Try relocating the antenna or using a more powerful or directional antenna Ensure the antenna cables are not running close to the power supply cables or the microphone wires inside the intercom panel Try a different SIM card from a different service provider as they may have better coverage in that area UU The intercom panel repeatedly beeps twice Check the power supply
35. mes to dialling into the GSM intercom depending on the telephone number you are dialling in from and the features setup during programming The three possible outcomes are shown in the table below and are shown in order of priority For example if the number is programmed to automatically activate the relay this will take priority over the following two options and if the telephone number is stored as a telephone number called from one of the push buttons this will take priority over the last option FUNCTION REQUIREMENT PRIORITY Dial in to open the door The telephone number of the telephone 1st dialling in must be stored in memory location After dialling the number the relay will STROO1 STR250 activate and the call will be dropped Dial in to activate a call Live speech The telephone number of the telephone 2nd activate relay AUXO dialling in must be stored in memory location STNOO1 STN050 or STDOO1 STDO50 After dialling the number the call will be answered and two beeps will be heard The speech will then be live Dial in to open the speech from a If neither of the two requirements above are 3rd number not stored in the GSM met memory After dialling the number the call will be answered and two beeps will be heard You will then be required to enter the four digit code to open the speech PAGE 30 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX RECORD SHEET MASTER CODE MA
36. n a manner consistent with the instructions provided the Enfora Enabler IIG module meets maximum permissible exposure MPE limits for general population uncontrolled exposure at defined in section 1 1310 of the FCC Rules and Regulations WARNING To comply with FCC RF exposure requirements a separation distance of 20cm 7 87 or more must be maintained between the antenna of this product and all persons Separate FCC approval for this product is not required as it will be classed as a fixed installation THIS PRODUCT IS NOT DESIGNED TO BE USED AS AN EMERGENCY CALL POINT The product is CE marked demonstrating its conformity and is for distribution within all member states of the EU with no restrictions This product follows the provisions of the European Directives 89 336 EEC amp 92 31 EEC EMC 73 23 EEC LVD and 93 68 EEC CE marking PAGE 38 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 _ VIDEX Date ___ Software Version Revision 16 07 2010 GSM1 0 2 Launch of 4810N 08 10 2010 GSM1 0 3 Altered dial in to open routine to allow numbers as short as 6 digits activate the relay Previously numbers were required to be 10 digits or more Now only checks a maximum of the last 8 digits of any number Improved call end routine now if a called number is busy not answered and there is no divert number stored the call will end immediately Previously the call would still run for the programmed call time
37. n nnn 11119TNnnn Delete the telephone number stored in location nnn A text message will be sent to the sender with the delete confirmation for that location nnn is a button number between 001 amp 050 The telephone number y can be a maximum of 30 digits Example To store the number 01912243174 for button 5 and a divert number if that one is not answered or busy of 01912241558 would be the following two SMS messages 11119TN005 01912243174 11119TD005 01912241558 STORING A TELEPHONE NUMBER FOR DIAL IN DOOR RELEASE STR Dial in door release allows users of telephones with their number stored to release the door gate simply by dialling the telephone number of the SIM in the intercom panel The intercom panel will check the callers ID when it receives a call and if it matches the list of stored numbers it will clear the call down Avoiding the caller being charged for the call and will activate the relay for the programmed time Up to 250 numbers can be stored The messages to check store or delete numbers are as follows PAGE 18 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VIDex 11119TRnnn yyyyyyyyyyy Store the telephone number yyyyyyyyyyy in position nnn where nnn 001 250 1111S5TRnnn yyyyyyyyyyy Store the telephone number yyyyyyyyyyy in position nnn where nnn 001 250and send a confirmation text message to confirm storage of new number 1111STRnnn Query the telephone number stored in location nnn where
38. na ART 4810N Ql UD Oe DH o WM c ou 00 p lt oj S9699999o999 9999 s Release PAGE 12 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX PUSH TO EXIT BUTTON AND AUXILIARY INPUTS OUTPUTS PUSH TO EXIT BUTTON TRIGGERS AUXILIARY OUTPUT OPEN COLLECTOR RELAY FOR PROGRAMMED TIME TRIGGERS WHEN g amp 5 ARE SHORTED ART 506N ART 4810N ART 4810N 12 12 eov Oe Se Cd CO bou D P 0D m OD Fe NM s i roo SHSSSesooogsgsges AUXILIARY 1 INPUT TRIGGERS AUXILIARY 2 INPUT SENDS A SMS AUXILIARY OUTPUT AO MESSAGE TO THE MASTER TELEPHONE NUMBER NOTE Once triggered it can t be triggered again for 4 minutes This avoids multiple SMS messages being sent for the same alarm ART 4810N 2 b und aa t g S 12 e ov gt Go OD OD Me Js x un or co ml OD OD Oe NM uua ro PAGE 13 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX STATUS INDICATION INPUT Using the following hardware and software configuration it is possible to interrogate an input to see if it is open or closed This feature can be useful to find out it a gate or door is open when it is not in line of site The input status can be interrogated in two ways During a call Press 9 on the telephone keypad and listen to the number of beeps heard in the ear piece One beep indicates cl
39. nn 03 When in this mode the AO terminal is used exclusively for monitoring the status of a switch to decide if calls should be divert to the master number or not 1111 Store the mode nn 00 03 1111AOMnn Store the mode nn 00 03 Also send a confirmation text back to the sender 1111 Query the current stored mode A text message will be sent to the sender showing the stored mode CHANGING THE FOUR DIGIT CODE CDE The four digit code can be any combination of numbers 0 9 but must be 4 digits long The code allows access to the programming menu in dial in mode and must be used when sending text messages to the intercom panel The following message changes the code 1111CDEnnnn nnnn new 4 digit code SET DAYS TO WAIT BEFORE MAKING A CALL NOD In the event the intercom panel is not used for long periods of time it could be possible that the network disconnects it To prevent this from happening it is possible to program a time period From 01 99 days to wait before the intercom panel makes a short call to refresh the connection This time period is reset after each call made on the system and will only happen if the full time period elapses without any incoming or outgoing calls PAGE 20 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 WX VIDEX 1111NODnn Store the time nn time in days 1111NODnn Store the time nn time in days Also send a confirmation text back to the sender 1111NOD Query
40. number of modules that make up the door panel The last digit of the frame code Indicates the number of modules it will take Frames are available in gun metal gray finish chrome finish Suffix C to the frame code or gold finish Suffix NG to the frame code Flush frames Surface frames Art 4881 Art 4886 POWER SUPPLY The GSM intercom panel is designed to work with power supplies in the range or 12 14Vdc The power supply should be capable of supplying a constant current of no less than 1 amp If the system is to work with failsafe lock releases or magnetic locks we would recommend a minimum of 2 amps The following Videx power supplies can be used AMR2 12 12 14Vdc 2A switched mode PSU Art 521B 13 5Vdc 1A DIN box PSU SP29 13 8Vdc 2A boxed PSU with battery back up facility SP28 13 8Vdc 3A boxed PSU with battery back up facility ANTENNA The GSM antenna connects to the SMA female bulkhead on the rear of the module A GSM antenna with a SMA male connector should be used Note An antenna must always be connected Note Always route the GSM cable away from the microphone wires and the power supply wires to avoid interference on the speech channels PAGE 11 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX WIRING DIAGRAMS Antenna e n4 lt Release Use either NO or NC depending on type of release OD D C c 0 0 xr i Qr 00 SGoGGSGOO OSSOOSSgSS Anten
41. osed and 2 beeps indicates open At anytime Send a SMS message 1111CHK to the intercom panel An SMS message will be returned with I P OP for open or I P CL for closed To use this feature auxiliary output mode must be set to 2 Used for status indicator and the input must be wired as shown below ART 506N ART 4810N 12 Trigger from gate door to indicate open or closed 656695656566959 NOTE WHEN USING THE AO OUTPUT FOR STATUS INDICATION IT CAN NOT BE USED AS AN OUTPUT FOR ANYTHING ELSE ALL CALLS DIVERT FACILITY AND CALL BUTTONS DISABLED FACILITY It is possible to have all call buttons diverted to the master number outside certain hours or when an input is active If there is no master number stored the intercom will beep to indicate no call is taking place To setup the time band follow the procedure in either the SMS programming section or the PC programming section of this manual To use a switch to enable or disable call divert to master number first the auxiliary output mode setting must be set to 3 Used to divert calls to master number and the input must be wired as follows e cO Mis ad lt co Switched input to E enable disable divert to NO master number NOTE WHEN USING THE AO OUTPUT FOR DIVERT TRIGGER IT CAN NOT BE USED AS AN OUTPUT FOR ANYTHING ELSE PAGE 14 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX 514 Connections for power
42. ptions to check it If a number is not programmed then it should be programmed while in the telephone The number can be obtained from the service provider Voicemail and text alerts must be switched off on the SIM card when using the dial in to release the door gate feature For Vodafone and O2 this can be done while the SIM card is in the intercom panel For Orange and T Mobile the SIM card must be remove and put into a mobile phone When storing the intercom panel s telephone number in your own mobile phone avoid using an obvious name such as Front Door or My Gate as this would make it easy to decipher if your phone was lost or stolen The PIN request feature must be disabled on the SIM card before using it in the Intercom panel It is likely on a new SIM card that it will not be enabled but if it is it will prevent the system from working at all This product may not be suitable for installation in hospitals health care facilities or in the presence of flammable gases or liquids Seek advice and authorisation before installing this product in these locations IMPORTANT NOTE ABOUT SIM CARD When using a pay monthly SIM card you must ask the service provider to put a spend limit on the account Vodafone call this service spend checker This is to safeguard against possible problems which could result in a large phone bill at the end of the month All providers offer this service You will need to either ring them or e mail them
43. re available in the drop down box message settings for more information beeps will be heard every few seconds Master Code The master code must be 4 digits Factory default 1111 and is required when BEL using the SMS facilities on the GSM unit and also when dialling in to the unit from a number which is not stored AUX2 Message The Aux2 message is a message which will be sent to the master telephone number when the Auxillary 2 input is triggered The message can be up to 32 characters but can t include spaces to be checked This must be stored to allow the balance to be checked SMS messages for low balance and Aux 2 triggered Time band The time band sets when the call button will call their relevant telephone numbers and when the call buttons will be diverted to the master number If no master number stored then the call will not take place and will be signalled by beeps from PAGE 26 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX the panel The ON time must be lower than the OFF time If this option is not required leave set as 00 00 23 59 CALL SETUP VIDEX GSM INTERCO From the call setup page it is possible to assign up to 2 telephone numbers to each Telephone No Divert Telephone No of the 50 available call buttons The divert telephone number will be used if the call is busy or not answered and will divert to this number after the divert time has elapsed If no divert number Is
44. rstand the different beeps heard and what if anything needs to be done in response to the beeps BEP SOLUTION Short beeps at 1 second intervals Relay or auxiliary output activated None this is normal Single short beep while the A valid text message has been None this is normal system is in standby and not received and processed being used long beep stored the button pressed Long beep followed by short beep Invalid text message received If this has happened when while the system is in standby sending one of the programming text messages then check the message for errors These beeps will also be heard if the 4 digit code in the text message is incorrect If you are unsure of the 4 digit code try resetting it to 1111 Long beep followed by short beep Manually ending a call by pressing None this confirms the call has while the system is in use a call button been cancelled Another call can be placed if required Leave it a short while to see if it manages to find the network If the beeps repeat every 30 seconds then try moving the antenna to a better location or changing the SIM to another network provider Six long beeps Unknown registering problem Try moving the antenna to a better location Try changing the SIM card to another network provider Eight long beeps Registered but roaming for a This could happen if it registers to better network another network instead of its pri
45. supply output to intercom panel and lock release connections 100m The power supply should be located as close to the intercom panel as possible for best performance Maximum acceptable resistance for above cables 30 INSTALLATION Check that all components are free from damage before installing Do not proceed with installation in the event of damage Keep all packaging away from children Do not obstruct the ventilation openings or slots on any of the devices All connections to mains voltages must be made to the current national standards IEE Wiring regulations Install an appropriate fused spur or isolation switch to isolate the mains Isolate the mains before carrying out any maintenance work on the system Avoid water ingress into the rear of the module always seal the module frame after installation using a suitable silicon based sealant All intercom and access control cables must be routed separately from the mains Lock release back EMF protection A capacitor must be fitted across the terminals on an AC lock release and a diode must be fitted across the terminals on a DC lock release as shown in the diagrams below to suppress back EMF voltages DIODE E 0 1uF capacitor 1 4002 _ 12V DC 5 LOCK RELEASE PANEL CARE The door panel s facia is either mirror finish stainless steel or matt finish aluminium It is important that the facia is cleaned on regular oc
46. tact relay 3A 24Vdc Normally closed connection of dry contact relay 3AQ120Vac Button matrix for connecting up to 50 call buttons PTE and auxiliary inputs See following pages for connections The PTE push to exit button connects across g 6 Auxiliary 1 input connects across g 5 Auxiliary 2 input connects across g 4 PAGE 6 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX EXTENSION BUTTON MODULES The GSM intercom module will accept up to 50 call buttons Any of the standard 4000 series button modules can be used as shown below Button 1 is in the bottom right corner counting up aaa Art 4842 Button emere fo _ IO LL _ e lu LO LO F 5 IO SSW _ JO OD JO SNe temm ep lege 5 pee 10 10 emm v ms ei amp Art 4843 Art 4844 M14645 Art 48420 Art 48430 Art 48440 Art 4645D connections to the GSM module are shown below Note For clarity power and other connections are not shown below Also take care when using additional button modules with intercom modules which also have buttons For example an intercom module with one button means the extension button modules must begin from button 2 an intercom module with 2 buttons means the extension module must begin from button 3 616 650 39 49 s rg CART 4810N ec NC 9 217 925 1 33 nm a 10 789 r 926 T 34 o_o
47. ter a two digit relay 3 time from 00 99 and then press enter Press enter twice PAGE 9 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL The red LED will illuminate to acknowledge programming mode If the red LED does not illuminate check the master code is correct If the master code may have been changed from the factory default and you do not know what it is then follow the factory default procedure on the following page This code can be from 4 8 digits and will not activate a relay It can only be used to enter programming mode Note this new code in the box provided on the next page It will be needed to re program the codes in the future This code will be used to open the door gate Relay 1 The code can be from 4 8 digits long and must be different from the engineer s code This is the time the relay 1 will energise for 00 will latch the relay when the code is entered and require the code followed by clear to unlatch This code will be used to open the door gate Relay 2 The code can be from 4 8 digits long and must be different from the engineer s code This is the time the relay 2 will energise for 00 will latch the relay when the code is entered and require the code followed by clear to unlatch This code will be used to open the door gate Relay 3 The code can be from 4 8 digits long and must be different from the engineer s code This is the time the relay 3 will energise for 00 will lat
48. the current stored time A text message will be sent to the sender showing the stored time DIVERT TIME DIT The divert time is the number of seconds to wait for a call to be answered before diverting to the second number The divert facility must be set for this to work The default time is 15 seconds The count down begins from when the call button is pressed but is refreshed when the telephone begins to ring and can be set to 01 99 seconds 1111DITnn Store the time nn time in seconds 1111DITnn Store the time nn time in seconds Also send a confirmation text back to the sender 1111DIT Query the current stored time A text message will be sent to the sender showing the stored time FORCED DIAL DLE A useful feature of the Intercom panel is its ability to call a number sent to it in a text message This feature can be used when setting up the SIM card For example disabling the voicemail facility or disabling automatic SMS messages or missed calls Any number up to 15 digits can be called and the call will last for a maximum of 40 seconds The example below would switch off voicemail on a Vodafone SIM card Substitute the Vodafone number for other service providers See important note on page 19 1111DLE 1210 Dial 1210 for the intercom panel Other useful numbers which can be used with this feature are as follows Please also check the service provider s web sits for other useful codes _ _ ___ Vodafone 0
49. to set this up Automatic top ups should also have a monthly limit PAGE 5 of 40 GSM DOOR INTERCOM TECHNICAL MANUAL VER 2 0 5 VX VIDEX SYSTEM COMPONENTS A system comprises of an intercom panel power supply SIM card and antenna The intercom panel is of modular design allowing it to be customised to the installation requirements by including proximity access control coded access or bioaccess and also including the correct number of call buttons INTERCOM MODULE The intercom panel can include any of the modules from the 4000 Series range and uses the standard 4000 series surface and flush mounting frames The GSM amplifier module is however essential and includes all the GSM communication electronics SIM card Supplied seperately and connections The intercom module is available in a O button 1 button 2 button amp 4 button configuration as shown below along with their part numbers Art 4810N 0 Art 4810N 1 Art 4810N 2 Art 4810N 1D Art 4810N 2D DIP SWITCH SETTINGS There are 2 dip switches located on 1 2 GAN dB the back of the module They can be ON 6 used to alter the volume from the Door Intercom speaker Additionally the volume can also be adjusted during a call via the telephone keypad CONNECTION DESCRIPTION 12Vdc 14Vdc input Ground connection OV auxiliary output Open collector Max 150mA Common connection of dry contact relay Relay contacts Normally open connection of dry con