Home

Marley-Cooling-Tower-Parts-Reference-Guide

image

Contents

1. 21st century manufacturing technology has enabled further advancement and the introduction of the new Marley Retlex RTM industrial fan cylinder offering a more dimensionally accurate high quality surface finish better fit and robust structural integrity A light RTM resin transfer molding closed molding process lends itself to increased durability for the final product and ensures laminate thickness and weight consistency Because the cavities are infused using rigid forms in the ribs there is no porosity or potential sites for delamination or structural fracture to begin Therefore the cylinder load capacity is greatly enhanced 1 800 462 7539 The green benefit of the closed molding process is the virtual elimination of VOC emissions because the resin is injected and cured in a sealed closed mold And because the lay up process is now dry a more precise laminate can be achieved with no hand working of resin soaked materials no cleaning requirements for application equipment no hand tools using hazardous chemicals and no chemical disposal concerns 41 H3 Fan True twisted airfoil design Solid cast aluminum alloy Infinite pitch adjustment Machined aluminum hub m 54 through 216 diameter Stainless steel hardware standard Cooling Tower Know How Axial fans require only half the operating horsepower of centrifugal blower fans Marley H3 cast aluminum alloy fans are A t
2. p TETI N E i BERR iA S B T n EE J gt Film Fi fe iiim MBX Crossflow Film Fill High efficient replacement crossflow film fill Single piece full height design Durable design adaptable to any crossflow fill configuration Thermoformed from 20 mil 020 thick PVC gt Marley Marley MBX Till is a high performing bottom supported PVC pack Till with integral louvers and drift eliminators specifically designed for the Aftermarket This Till will make installation easier and faster while at the same time offering great cooling efficiency without major tower moditications MBX Till incorporates highly efficient cellular drift eliminators integrally molded within the Till sheets These eliminators may reduce drift emissions trom the tower by a factor of 10 or more Louvers are also integrally molded within the Till sheets preventing water from escaping and ensuring precise air distribution throughout wide variations in airflow 1 800 462 7539 MBX Till packs are available in various heights and air travels from 24 to 48 and can be installed in almost any crosstlow cooling tower regardless of tower age or manufacturer Retrofit kits including MBX Till packs fiberglass supports stainless steel hardware and installation instructions are available MBX fill is manufactured from inert material thus ensuring a long operating lite with minimal maintenance The wide
3. Ke z NNN EE e mS oo treatment chemical costs The nuisance of spotting adjacent buildings and property due to cooling tower drift is virtually eliminated Options include eliminators for both vertical and horizontal discharge cooling towers Guiding the discharge air in the right direction further increases savings in fan horsepower M106 is thermoformed from PVC sheets with a maximum flame spread rating of 25 per ASTM E 84 Therefore the risk of fire damage is minimal Buy Marley Parts com ke e N duch Xw n N n Stn d SEE Ce NN a ew E MA dp ia wi M106 fill is impervious to rot corrosion and decay The wide sheet spacing prevents clogging ensuring minimal maintenance and long service life M106 is easy and inexpensive to install in almost all crosstlow cooling towers It requires minimal structural modification because it is bottom supported The integral drift eliminators don t need extra frames or retainers M106 provides more cooling capacity and improved drift elimination in one easily installed pack 24 HE HED nn Alpha Crossflow Splash Fill High performance Heavy duty m Easy cleaning Direct replacement for wood lath fill Marley Alpha fill will increase cooling tower thermal performance capacity compared with wood lath on similar spacing Variable fill bar spacing is available to provide the required thermal performance Alpha fill bars are cor
4. ane 5 50 1 323 968 75 60 ES E 6 12 1 289 240 60 50 6 50 1 972 226 55 45 733 1 241 201 40 30 8 67 1 204 170 31 Ss 5 06 1 351 999 150 125 5 44 1 326 271 150 125 6 14 1 289 240 150 125 3000 6 85 1 259 215 150 125 1250 16 5 791 1 994 186 150 125 8 80 1 902 168 131 110 9 60 1 185 154 113 94 gt Marley Nominal input speed is assumed to be 1775 RPM at 60 Hz and 1475 RPM at 50 Hz Rated at AGMA 2 0 Service Factor 1 800 462 7539 35 Geareducer Double Reduction Outstanding durability Designed specifically for cooling tower duty Designed to meet or exceed the requirements of CTI Std 111 Gear sets meet or exceed the requirements of AGMA Quality No 9 to 11 Minimum Lou service life of 100 000 hours on both input and output shafts Input shaft nitrile lip seals Premium seals available Output shaft sealed with a maintenance free labyrinth ring Timken tapered roller bearings Two stage spiral bevel helical gear reduction for efficient power transmission Marley Industrial Geareducers are manufactured and designed specitically tor cooling towers in large industrial and power plant applications In shape and function their design goes beyond normal AGMA requirements both to maximize air movement through the tower and to minimize the impact of maintenance Although the primary function of a Geareducer is to reduce the speed of the driver usually an electric motor to a speed wh
5. Empty Oil Capacity Model Weight Ration 60 Hz 50Hz 60 Hz 50Hz Ib US gallon LS 229 187 125 100 8 80 1 202 168 150 150 9 82 185 153 150 150 32 2 10 1631 175 145 150 125 1700 9 0 o 159 UE 150 150 12 93 1 lor 114 150 125 14 64 1 ER 100 150 125 9 93 1 179 149 150 125 3400 1035 Kn 143 125 100 9810 185 11 16 1 159 132 150 125 ZS 137 114 150 125 9 64 1 184 153 207 217 10 83 1 164 136 251 he 3600 11 55 1 154 128 218 184 3000 18 5 IESEL 137 114 213 180 14 84 1 119 99 188 159 9 64 1 184 153 316 22 10 83 1 164 136 316 2 11 95 1 154 128 304 263 IESSE 146 2 326 274 12 98 1 137 114 304 263 13 24 1 134 IO ZE 21 4000 3200 18 5 13 81 1 129 107 290 244 14 88 1 119 99 25 SI 15 84 1 112 93 201 214 16 49 1 108 89 204 175 18 54 1 96 80 204 175 SE 90 19 204 174 Marley Nominal input speed is assumed to be 1775 RPM at 60 Hz and 1475 RPM at 50 Hz Rated at AGMA 2 0 Service Factor 1 800 462 7539 37 Geareducer Ou Filled with Reliability It is critical to the operational life of a transmission to utilize a satisfactory lubricant that includes the correct viscosity grade and additives Additionally it should be within the specitic limitations of contaminants and fill volume throughout the machine lifetime Marley Gearlube is a premium quality synthesized hydrocarbon lubricant that is specially formulated to deliver extended lite without oxidation or loss of lubricity It is tree of undesirable elements that can produce
6. _e_e_rr nerersr geeeeeJ 44 Z r r rJJ v D 45 EE EE 46 Series 400 Driveshaft w u uu uuuurnnsnnasm nccnnsssiamm s 47 RE 48 Gol lO Dl VE S Dl yaka eT iih 49 eo l re cm 50 Cooling e 51 Controls Can Do Fan Motor Control Fame 52 Variable Speed Drive e Baan ei 54 Multicell Motor Zeguence EEN O Water Level Confrol AAA 56 M 95 Vibration O W R s icu ncuucnainde nu donnclr al nan danini i 58 Rental Cooling Tower ENEE 59 Aftermarket Services Reconstruction 60 Cooling Tower Fundamentals uk ucc ca 61 Maintenance Schedule AEN 62 ch di gt E TTS 3 gt Marley Buy Marley Parts com SpiralTarget Crossflow Nozzles Patented design The standard in crossflow nozzle design Available in 3 lengths to fit virtually every structural configuration 13 orifice diameters available for optimum performance adjustments No moving parts Wide range of adjustments in water flow rate The Marley SpiralTarget nozzle is an injection molded polypropylene unit consisting of two parts the main body with integral target diffuser and a snap on insert or orifice cap The orifice cap is available in 13 diameters ranging from 362 through 1 099 This amount of flexibility allows for a wide range of adjustment in water flow rates and basin water levels gt Marley The Spira
7. cooling tower environments Omega Till and its support system are designed to be used in virtually all cooling towers regardless of a cooling tower s age or manufacturer 28 HE HED aen Permagrid Counterflow Splash Fill Extremely durable 25 year guarantee E Easy cleaning Dirty water application gt Marley Ceramic Permagrid tile fill is the most durable fill in the industry with a guaranteed minimum of 25 years of service Molded from domestic clay to strict specifications the clay is heat tired to create a fill that is immune to traditional fill deterioration problems Because this revolutionary tile fill is not affected by ultraviolet exposure and fungal attack cooling towers with Permagrid tile fill are pertectly suited for harsh operating environments involving temperature extremes This tile fill exhibits low water absorption such that it will withstand extreme freeze thaw environments common in cold weather climates or free cooling applications 1 800 462 7539 Characterized by large openings Permagrid tile is an excellent performer in the high solid contents environment of dirty water applications Permagrid is set without mortar adhesive or mechanical connections so no regular maintenance is necessary The installed system is placed in a pattern designed to provide optimal thermal performance 29 TrickleBloc Counterflow Splash Fill High Performance High density c
8. rotation The sequencing controllers prevent the same motor from always starting first in the normal sequence of operation Every 24 hours a different motor becomes the lead stage equalizing the wear on all motors 1 800 462 7539 The sequencer can easily be configured for single or two speed motor systems On two speed systems the unit can be set to cycle through a Lo1 Lo2 Lo3 Hi1 Hi2 Hi3 or Lo1 Hi1 Lo2 Hi2 Lo3 Hi3 sequence The controller recognizes the two speed motor settings and only uses low speed as a lead stage Adjusting the temperature set point and activating cells can easily be accomplished at the unit 53 Water Level Probes Liquid Level Control Marley liquid level controls provide you with state of the art systems to control and monitor the water level in your cooling tower collection basin Relays operating in conjunction with suspended stainless steel electrode probes monitor basin water levels providing simple solenoid valve water makeup or discrete on off signals to more sophisticated automation controls Up to seven probes may be provided in a single head unit Optional contigurations might include any contigurtation of the following combinations Water level make up with a solenoid valve High and low alarming back to a BMS High level cut off for pump control Low level cut off for pump control Each probe is furnished with 20 feet of wire gt Marley Electrode P
9. the next step and filled every System 5 Geareducer with Marley Gearlube lubricant In addition several improvements to the System 5 Geareducer have been made to take advantage of the extraordinary lubricating properties of Gearlube We ve equipped it with a strong magnet in the sump to trap metal particles generated during the initial break in period Buy Marley Parts com Rebuild Kits Available Marley Geareducer kits offer a single consolidated shipment of all the materials you need for repair rebuild including gears bearings oil seals O ring seals shims and oil 34 Geareducer Single Reduction Output RPM Input hp Limitations Empty Model Reduction Weight Oil Capacity Ration 60 Hz 50Hz 60 Hz 50Hz Ib US gallon 9 1331 832 692 75 75 9 61 1 679 564 75 75 EN 3 27 1 543 451 75 75 n 3 77 1 471 391 75 75 2 din 655 544 34 28 3 27 1 543 451 30 25 1800 3 75 1 473 393 25 19 210 2 4 4 09 1 434 361 2i 17 4 80 1 370 307 15 19 TIR 655 544 57 49 3 27 1 543 451 51 5 44 2000 3 75 1 473 393 41 5 35 5 210 2 4 4 09 1 434 361 34 5 30 4 80 1 370 307 97 93 5 3 45 1 514 428 70 60 3 79 1 469 390 70 60 4 10 1 433 360 70 60 4 56 1 389 323 70 60 5 11 1 347 989 70 60 SR 5 50 1 323 268 61 53 SE 6 12 1 289 240 50 43 6 50 1 226 47 41 733 1 941 901 32 28 8 67 1 204 170 29 25 3 45 1 514 428 143 121 3 79 1 469 390 133 110 4 10 1 433 360 103 90 4 56 1 389 323 88 75 5 11 1 347 989 80 70
10. two workers Long service life Rugged design includes carbon fiber epoxy composite tube with stainless steel flanges and neoprene flexible elements Also vibration is internally dampened to 1 800 462 7539 prolong alignment and transmit less vibration to the motor and gearbox All materials are specially selected for cooling tower duty and longer life The composite tube prevents transient start up vibration Corrosion resistant Materials such as composite carbon fiber epoxy stainless steel and others help prevent corrosion Easily interchanged Owners with Marley 301 stainless steel driveshafts can upgrade to the Series 400 simply by exchanging their existing driveshaft tube assembly with the new carbon fiber tube assembly and using the existing driveshaft yokes 47 Marley Driveshaft Specs lt m_ _ _ OVERALL LENGTH gt lt ENGAGEMENT lt ENGAGEMENT E Q ronnen GEAREDUCER DISTANCE BETWEEN SHAFT ENDS DBSE SH L YOKE DIAMETER BORE Series SC DBSE Diameter Diameter TUBE DIAMETER gt Marley Buy Marley Parts com 48 Comp DS Driveshaft Low maintenance Easy to install Modern construction Easy to align Long service life UV and corrosion resistant Easily interchanged Comp DS composite driveshafts provide a high performance lightweight and low maintenance alternative to steel driveshatts Marley s patent pending u
11. while maintaining thermal efficiency this then allows for the use of film Till where fouling risks occur Buy Marley Parts com LI L Wi i A A Ir r t i W A Li FE nan e j ra D z ia d D M Li ie wa SR Kuel gg See Bieser Sage d kb b O KH vie a Ta P 5 i z lk mk TEW L n Each module consists of vertically channeled flat and corrugated surtaces which essentially avoids contact between the sheets thus eliminating water concentration The horizontal corrugations and their location within the sheet promote optimum mixing of air and water The flutes in the MVC20 fill are vertically and aerodynamically shaped resulting in a reduction of pressure drop 16 Tell WNN LF E r L EH A N m Wm ll d 5 i an a by 4 Bi Bi I y A WII J MC120 Counterflow Film Fill High performance design Bottom supported Requires minimum number of supports Log configuration Ideal replacement for Marley MC47 counterflow fill Marley MC120 is a high pertormance film fill system designed for factory assembled counterflow towers offering you several distinct advantages Textured crossed corrugations provide the surface area and turbulence to develop efficient heat transfer The corrugations inherently establish uniform fill sheet spacing at 0 45 gt Marley MC120 fill is thermoformed trom 015 thick UV inhibited chemicall
12. 2 3400 3600 and 4000 Geareducer models they can also be utilized to fit legacy 32 17 34 31 34 4 36 and 38 Geareducer models gt Marley When operating the outer race is stationary and the inner race is rotating When facing the input shaft of the Geareducer the forward over running direction is clockwise In contrast to conventional sprag clutch devices which may continuously wear this device utilizes a Lift off sprag functionality which alleviates the wear issue once typical rotation speeds are reached This feature greatly diminishes the friction and heat generated thus promoting longevity for both the clutch unit and the Geareducer itself Buy Marley Parts com The backstop shall have a torque capacity of at least 1100 ft lb 1490 N m and shall be capable of continuous overrunning operation at 1800 rpm 40 Reflex RTM Fan Cylinder Having designed and manufactured cooling tower fan cylinders since the 1930s Marley began producing FRP fiberglass fan cylinders in 1958 which quickly became the accepted standard within two years time With considerable modeling and full scale testing this experience led to the development of several new fan cylinder designs for a variety of tower types and fan sizes One such development resulted in the Reflex velocity recovery cylinder in the 1980s and is the standard design still in use today tor 10 diameter and larger tans gt Marley
13. Check for loose driveshaft or coupling fasteners Check driveshaft or coupling bushings or flex element for unusual wear Lube lines if equipped Check for oil leaks in hoses or fittings Belt drive if equipped Fan shaft bearing lubrication every 3 mo Check and tighten support fasteners Check shaft sheave and belt alignment Check belt tension and condition Check sheave bushing fastener torque Fan Check and tighten blade and hub fasteners Check fan blade pitch and tip clearance Check fan cylinder for loose fasteners Motor Lubricate grease as required Check mounting bolts for tightness Operate at least Basin Heater if equipped Check for proper operation of temp low water level sensor Inspect clean buildup of contaminant from sensor Structure Inspect tighten all fasteners Inspect and touch up all metal surfaces gt Marley Monthly Semi annually rr a a a ee _ _ _ _ _ zzzAzAa e zzy nl i 3 hours a month 3 hours a month ln len Buy Marley Parts com Seasonal Startup or Annually X every 3 months x X R X 3 hours a month 62 SP Lenntech info lenntech com Tel 31 152 610 900 OVERLAND PARK KANSAS USA www lenntech com Fax 31 152 616 289 P 913 664 7400 F 913 664 7439 SPX COOLING TECHNOLOGIES INC 7401 W 129 STREET E spxcooling spx com spxcooling com In the interest of technological progress all products are subject to design and or material change wit
14. ISCHARGE ANGLE AIR FLOW Marley XCEL Drift Eliminators Marley XCEL drift eliminators discharge air at an angle of 45 to 53 with respect to the horizontal The exact angle depends on the specific eliminator and on the slope of the tower frame The directional changes incorporated in Marley s three pass drift eliminator act as turning vanes to induce the discharge air flow through a gentle turn from the horizontal toward the vertical To be sure of efficient cooling tower performance always demand that drift eliminators in large crossflow towers must provide a discharge angle as defined by the angle of the last section of the eliminator itself at least 40 from the horizontal Otherwise unnecessary and costly turning losses will occur in the plenum gt Marley Some drift eliminator manufacturers overlook this fact and do not include turning vanes on their cellular drift eliminators Serious performance problems can occur because of this oversight R amp D investigations have demonstrated that some cellular drift eliminators in crossflow towers actually reduce thermal performance by 4 to 8 because they direct the discharge air inefficiently Discharge air from some cellular drift eliminators actually enters the fan plenum at an angle below or near the horizontal The fan energy is wasted because it must force the air stream through a turn of more than 90 This resultant increase in pressure loss reduc
15. LENN TECH www lenntech com Fax 31 152 616 289 cooling tower parts reference guide OEM PARTS FOR MARLEY COOLING TOWERS AND FLUID COOLERS EZO XE SP Current Brands Marley Recold Hamon Dry Cooling gt Marley Lenntech bv Legacy Brands Balcke Ceramic Custodis Ecodyne Davenport Head Wrightson Heenan Coolers Pritchard Zurn Balcke D rr ee ABALCKE RECOLD Buy Marley Parts com 2 E Water Distribution e 5 COUNT Or ROWE NOZZE S scccsscoststatestoss Sicinthsnnisainanetotnssoimeapiedbceseesbearetbaert 7 Counterflow Distribution System y s se eras 9 EE 10 HC Ee 11 Make Up Float Valve EEN 12 Fiberglass Hot Water BaShi xun nan n nanna atan knan ki 13 Counterflow Film Fill E EE 14 EE EE 15 EEN 16 EE 17 EEN 18 Cleanlow n AF YO SAF i kk nanan eu 19 err 20 MGR FUN T eegene 21 Crossflow Film Fill Ee 22 E E 23 Ee 24 Crossflow Splash Fill nt ggg gxgg pvpaw 29 leede 26 Ee E 27 EE 28 Counterflow Splash Fill Lc ee 29 meke Blot Fil cts can zahdarakdmiabala t aainaniinainlnninlu nlne ininnnia 30 GridLoc Splash Fill Support e Marley 1 800 462 7939 Drift LEO ee 32 Fans and Drives Single Reduction Gearechucer seet 34 Double Reduction GearedUuCef sssssisirsin 36 Ee Eeer 38 Geareducer Sound Lewels ENEE 39 prag Eege 40 kelot RIM Fan CYNOG Geet 41 ela E 42 Ee 43 e eeee
16. The GridLoc splash bar grips are compatible with many Marley splash bar designs as well as commercially available bars GridLoc will retrofit on historic Marley Class 600 as well as other manufacturer s crosstlow cooling towers 31 XCEL TU Eliminators Cellular design Low pressure drop Very low drift rates Counterflow and crossflow designs Marley developed the first cellular drift eliminator in the 1970s when eliminator designs were primarily ineffective blade type contigurations Next Marley patented the XCEL generation of eliminators in the early 80s No other eliminator could come close to XCEL eliminator s low drift rate and low pressure drop Now virtually every eliminator is a nesting cellular PVC type design XCELplus is a more advanced design that meets or exceeds today s demanding specitications for drift emissions without sacrificing tan horsepower Drift rates are currently half that of the original XCEL design with equivalent pressure drop gt Marley The eliminator discharge angle is important enough to warrant two separate eliminator designs one Tor crosstlow and one for countertlow towers Tests show the air direction leaving the eliminator is extremely important impertect designs create additional work for the tan This means either increased Tan horsepower or reduced cooling tower performance The crosstlow version features drainage slots within the eliminator pack to ensur
17. al seats In a shut off position the stem and yoke are external to the water eliminating the necessity of valve stem packing gt Marley 1 800 462 7539 11 Water Make Up Float Valves Heavy duty red brass body construction Buna rubber seal disc assures positive shut off Free flow outlet Fully adjustable Available from 3 8 through 2 diameters Floats available in polypropylene or copper Designed specifically for cooling tower duty Marley make up water float valves provide long life with little maintenance Typically valves are available in complete kits which include valve float arm and float in kits to fit a specitic application When installed some trial and error adjustment of the float valve may be required to balance the makeup water with tower operation Ideally the float Maintenance Know How valve setting will be such that no water is wasted through the overflow at pump shutdown However the water Maintain inlet water level after pump start up must be pressure at or below 50 deep enough to assure positive pump psig to ensure long valve suction seal life gt Marley Buy Marley Parts com 12 FRP Basin DuraLast FRP Hot Water Basin Marley DuraLast FRP Basins offer many advantages compared to wood basins Corrosion resistant Extremely stable Fire resistant Easy installation ideal replacement for wood basins High strength Light Weight No preservative treatmen
18. configuration and higher performing MX625 configuration MX is a hanging film type cooling tower fill which spreads the water into a thin film flowing over large vertical surfaces promoting maximum exposure to air flow This type of Till provides much more water surface exposure per cubic foot than splash type fill MX Till incorporates highly efficient cellular drift eliminators integrally molded within the Till sheets Compared gt Marley with previous designs these eliminators reduce drift emissions trom the tower by a factor of ten or more Less drift means tower owners save on water and water treatment chemical expenses This Till virtually eliminates the nuisance caused by drift spotting on adjacent buildings and property For additional savings the drift eliminators discharge air directly toward the fan Discharge air traveling in the right direction when it leaves the eliminators translates to lower tan horsepower Buy Marley Parts com Louvers are also integrally molded within the Till sheets preventing water from escaping and assuring precise air distribution throughout wide variations in airflow Unlike towers equipped with separate external louvers this fill operates virtually ice free even in extremely cold weather MX fill is thermotormed trom PVC with a flame spread rating less than 25 per ASTM E 84 and is considered self extinguishing Therefore the risk of Tire damage is minimal 22
19. ds Single enclosure for all control cards Level cards as required for following conditions Make up Hi alarm Lo alarm Hi level cutout Lo level cut out gt Marley 1 800 462 7539 57 M 5 Vibration Switch Meets all requirements for mechanical switches on one package Weatherproof and optional hazard area rating Local and optional remote reset with startup delay SPDT or 2 SPDT switch output contacts The Marley M 5 vibration switch is designed to meet all requirements for mechanical switches in a single affordable package This unit provides economical vibration protection for cooling tower mechanical equipment An inertia sensitive mechanism activates a snap action switch with men es SPDT output contacts if the vibration exceeds an adjustable setpoint DPDT CONTACTS SPDT CONTACTS The M 5 contacts can be used to activate an alarm or initiate equipment shutdown The housing is weatherproot with an optional hazardous area rating User Wiring Diagrams gt Marley Buy Marley Parts com 58 Cooling Towers Temporary Cooling Disaster response Maintenance outages Repair replacement cooling A sense of urgency that gives new meaning to the word fleet In this business every minute of cool water flow and every minute variation in water temperature counts regardless of whether you provide emergency backup or increase production capacity Because it all equates t
20. e trapped drift is returned to the wet side of the cooling tower Low drift rate is the primary goal of eliminator design XCELplus boasts typical drift rates of 001 of the total GPM Lower drift rates are available depending upon tower configuration Buy Marley Parts com XCEL eliminators require little or no maintenance It it becomes necessary to clean them care must be taken not to physically damage the PVC eliminator packs For loose deposits of silt fibers etc a water spray can be used provided the spray nozzle is kept moving continually and the water pressure is not excessive recommend less than 30 psi Chemical cleaning can also be done If an acid product such as inhibited sulfamic acid or glycolic acid is used tor chemical cleaning of a scale deposit e g calcium carbonate care must be taken that the acid does not attack other materials in the cooling tower or system such as steel The acid should be quickly and thoroughly rinsed off all metal surfaces Do not use cleaning agents which contain hydrocarbon solvents 32 A Turn For The Better lt is widely accepted throughout the air handling industry that turning vanes significantly enhance the performance of any system that includes a major change in air flow direction A crossflow cooling tower is such a system Air enters the tower horizontally and must turn to the vertical before it can exit through the fan stack l ELIMINATOR 45 T0 53 D
21. eat transfer gt Marley Texturing creates thermal capability improvement with little effect on fouling DF254 offers low pressure drop in an aerodynamic durable design DF254 is easily adapted to any tower s configuration To accommodate Tor various Till heights and or desired duties DF254 may be installed in multiple layers DF254 fill is thermoformed from 020 thick UV inhibited chemically resistant PVC polyvinyl chloride The material is extruded and manufactured to rigid specifications before forming at one of Marley s plastics facility Buy Marley Parts com Cooling Tower Know How What ts the ifference between DF254 and DF381 DF254 is a higher performing low clog fill DF381 should be used where there is a greater risk of clogging or fouling 14 KE HD XEME DF381 Counterflow Film Fill High performance low clog design Bottom supported Requires minimum number of supports Log configuration Marley DF381 is a film fill system designed to signiticantly reduce the risk of biological fouling without sacrificing high performance heat transfer DF381 is a bottom supported low clog log fill configuration Open angular cross corrugations allow debris and biological growth foulant to pass while providing maximum surface area and turbulence to develop efficient heat transfer Texturing creates thermal capability improvement with little effect on fouling DF381 offers low pre
22. es 1 3 5 of Marley Full cone distribution pattern assures NS nozzles are large enough that uniform water distribution for all film many competitive nozzles will actually fills Minimal spray overlap is required fit inside a Marley nozzle Marley providing unitorm water distribution counterflow nozzles have no internal even near spray boundaries Marley NS parts or narrow passageways The counterflow nozzles develop uniform attached diffusion ring will not retain water distribution over a wide range of even fibrous debris operating water pressures gt Marley Buy Marley Parts com 8 Counterflow Distribution Assembiy Self Draining Economical Installation Economical Operation Easy disassembly and Reassembly Larger pipe spacing Easily adapts to a variety of nozzle spacings Spray Arm Extender Adapter EPDM Grommet gt Marley Assembly of the entire system requires only a few simple hand tools All connections are positive yet the design allows repeated disassembly and reassembly Nozzles are installed in pairs each supply pipe serving multiple pairs of nozzles Multiple nozzle pairs per supply pipe mean larger pipe spacing and therefore lower installed cost than most other systems The adaptor allows nozzle spacing on 3 O centers 1 800 462 7539 The nozzle outlet is always the lowest elevation in the distribution system This arrangement is self draining when the supply water is shut off The
23. es the total air flow through the tower Reduced air flow means reduced thermal performance R amp D studies have determined that these eliminators can increase the fan horsepower required for a given cold water temperature by as much as 25 or the owner will be forced to accept an increase of up to 2 F in cold water temperatures ELIMINATOR 0 TO 15 DISCHARGE ANGLE Other Cellular Drift Eliminators 1 800 462 7539 33 Geareducer Single Reduction Outstanding durability Designed specifically for cooling tower duty 5 year oil change interval Minimum Lou service life of 100 000 hours on both input and output shafts Gear sets meet or exceed the requirements of AGMA Quality No 9 Input shaft nitrile lip seals Premium seals available Output shaft sealed with a maintenance free labyrinth ring Timken tapered roller bearings For over 40 years the Marley Geareducer has been one of the most rellable geared speed reducers designed specitically for cooling tower Service The reliability of the Geareducer comes from more than 100 000 units of experience and trom Marley s attention to exacting quality standards of design and manufacturing Today every Marley Geareducer is tested under load at our factory Then it s inspected and adjusted before shipment gt Marley Outstanding Geareducer engineering is only as good as the lubricant that protects it Thats why we took
24. for mounting into the tower outlet water piping 53 Basin Heater m Pre engineered UL Listed CSA approved package for freeze protecting cooling tower basins Stainless steel heating elements Complete control package Basin Heating Element Basin Heater Control Panel with Low Water Safety Circuit The system usually consists of one or more stainless steel electric immersion heaters installed in threaded couplings provided in the side of the basin A NEMA 4 enclosure houses a magnetic contactor to energize heaters a transtormer to provide 24 volt control circuit power and a solid state circuit board tor temperature and low water cut off Submerged in basin water in which zinc ions are present copper immersion heaters must not be used Insist upon stainless steel gt Marley Buy Marley Parts com 54 Motor Sequencer Multicell Motor Sequencer Simple to install and operate Eliminate multiple fan thermostats Single set point stages multiple fans Marley performance matched sequencer available in either 8 or 16 stage systems will stage multiple fan cells of a cooling tower from a single temperature measurement location based upon a single temperature set point Old mechanical thermostats with staggered set points on each cooling tower fan cell are no longer necessary gt Marley Marley controls help extend the lite of the fan motors with automatic lead stage
25. gs pressure compensated Marley cooling tower duty motors utilize a double dip and bake impregnation process for the insulation system to increase mechanical endurance and moisture resistance Additionally an epoxy paint coating system is used externally and internally to inhibit corrosion Multiple end bell drains allow for quick removal of condensation regardless of the motor mounting positon Automatic terminal box drain plugs a rubber lead separator V ring slingers on both end shields and an additional external water slinger all aid in increasing the motor s longevity gt Marley Marley cooling tower motors meet or exceed all NEMA Premium and CEE requirements tor energy efficiency These TEFC motors are built according to NEMA specitications and designed for operation in moist or dusty atmospheric conditions without affecting useful lite Motors are NEMA Design B and maintain exceedingly high breakdown and locked rotor torque while providing the highest rated efficiency levels 1 800 462 7539 Cooling Tower Know How TEFC motors offer additional benefits over TEAO motors whose only Source of cooling is the flow of air produced by the cooling tower fan 51 Gan Do Fan Motor Control Panel Electrical components External disconnect handle with padlocking provisions to meet lockout tag out safety requirements Main circuit breaker with thermal and magnetic overload protection Door mo
26. hout notice ISSUED 11 2011 PRG 11B COPYRIGHT 2011 SPX Corporation
27. ich is conducive to good fan pertormance it must satisty other criteria as well For example it must provide primary support for the fan withstand the shock loads imposed at gt Marley start up and during subsequent speed changes anchor the fan against lateral movement in response to rotational forces and contribute as little as possible to power transmission losses as well as the generation of noise Given these requirements many manutacturers of mechanical equipment provide acceptable speed reducers Designed for more forgiving commercial applications these units are often unprepared for the rigors and peculiarities of cooling tower service such as the corrosive effects of operation often intermittent within an exceedingly humid environment As a result both the life expectancy of Buy Marley Parts com these commercial speed reducers and the thermal performance of the cooling towers on which they are installed often suffer SPX Cooling Technologies is the only major manufacturer whose gearboxes are designed uniquely for cooling tower service And since we warrant not only the Geareducer but the thermal performance of the cooling towers on which they operate as well development design and manufacture are taken very seriously This has resulted in an unequalled history of trouble free operation 36 Geareducer Double Reduction Reduction Output RPM Input hp Limitations
28. ion molded high impact black polypropylene Each nozzle is a single assembly with no moving parts gt Marley Buy Marley Parts com 6 Water Distribution NS7 Counterflow Nozzles E Available in two sizes E Easily removed for cleaning No moving parts E Wide range of adjustments in water flow rate NS7 Nozzle with Turbulator installed gt Marley The Marley NS7 countertlow nozzle is an injection molded polypropylene unit consisting of two parts the main assembly with integral turbulator and an EDPM rubber grommet NS7 nozzles are designed to economically provide desired thermal performance at low spray heights typical of factory assembled cooling towers NS7 nozzles are produced in two sizes The NS7 150 has a nominal insert OD of 1 and the NS7 200 has a nominal insert OD of 2 Recommended spray height above the fill is between 7 and NS7 EDPM Grommet 15 NS7 grommets are made from EDPM rubber with a durometer rating between 45 and 50 1 800 462 7539 NS5 and NS6 Counterflow Nozzles Patented design Easy to install no tools required to install into adaptor pipes Clog resistant No moving parts Self draining Cooling Tower Know How Why are there two styles of counterflow NS nozzles Typicallyt heN S5 is used in most locations The NS6 will handle higher GPMs and is used in areas where obstructions limit the use of NS5 nozzles Marley NS6 Nozzle The orifice siz
29. l Target nozzle is available in three lengths The 2 625 nozzle is used on wood steel and fiberglass cooling towers where basin support structure does not obstruct the release of water The 4 875 nozzle is used on larger industrial wood and concrete cooling towers and on applications where clogging might be a concern The 6 875 nozzle is used on towers where the release of the water has to clear obstructions within the tower structure In every application the target portion of the nozzle should be located at the correct distance above the top of the cooling tower Till to obtain maximum water distribution over the fill area 1 800 462 7539 Snap on Orifice Maintenance Know How When cleaning basins avoid using a round dowel to clean nozzles In most cases the daisy at the end of the nozzle will be knocked off which will destroy the distribution performance of the nozzle Best practice is to remove the nozzle for cleaning NX Crossflow Nozzle A truly clog resistant crossflow nozzle m Nozzles are spaced on nominal 2 0 centers m 1 875 and 2 5 orifice diameters available The Marley NX nozzle is used only The NX nozzle is the ideal solution on splash fill crosstlow towers where for overflowing basin problems due to objects in the water supply create clogged nozzles in splash till industrial blockage in smaller nozzles crosstlow cooling towers NX nozzles are inject
30. l performance Low maintenance m Low clog design Marley MCR is a film fill system designed to signiticantly reduce the risk of biological fouling while minimizing the loss of high performance heat transter Open offset vertical corrugations allow debris and biological growth foulant to pass while providing maximum surface area and turbulence to develop evaporative heat transfer Smooth surfaces without sharp intersections maintain water velocities and reduce gt Marley the number of restrictions where biological growth begins MCR fill is thermoformed from 015 thick chemically resistant PVC polyvinyl chloride Material thicknesses of 020 and thicker are also available MCR is easily adapted to any tower s configuration The fill pack depth 1 800 462 7539 fill height is variable to provide the proper heat transfer area within a single Till layer MCR countertlow Till can be hung trom structural members or it can be bottom supported in virtually all counterflow cooling towers regardless of a cooling tower s age or manufacturer 21 HE HED nn Ma Crossflow Film Fill High Performance Hanging fill design Integral louvers Integral triple pass eliminators Cooling Tower Know How Always replace MX fill with genuine Marley MX fillin order to maintain your FM approval rating Knock off fill designs may reduce performance and void FM approval Marley MX Fill is available in MX75
31. ley Parts com 18 HE HD en Cleanflow AAFNCS Counterflow Film Fill Vertical flute film fill Low maintenance Low clog design Low pressure drop Marley s Cleantlow anti fouling film type Till consists of themotormed corrugated sheets made of rigid polyvinyl chloride PVC impervious to decay fungus and biological attack The sheets are bonded to form modules which can be dimensioned to Tit any application gt Marley Cleantlow fill combines properties related to a media s ability to allow substances to migrate through it while maintaining thermal efficiency this then allows for the use of film Till where fouling risks occur 1 800 462 7539 Each module consists of vertically channeled flat and corrugated surtaces which essentially avoids contact between the sheets thus eliminating water concentration The horizontal corrugations and their location within the sheet promote optimum mixing of air and water The flutes in the Cleanflow Till are vertically and aerodynamically shaped resulting in a reduction of pressure drop 19 HE HED nn MC75 Counterflow Film Fill High Performance Hanging or bottom support design Variable air travel sizes Cross corrugated design Marley MC 5 is a film fill system designed for countertlow towers offering you several distinct advantages Crossed corrugations provide the surface area and turbulence to develop efficient heat transfer The cor
32. mance Testing you can t know how much any reconstruction effort has improved your tower unless you know how your tower is performing now Our staff of Testing and Ratings Engineers can help you to gain that vital information Buy Marley Parts com 60 Publications Fundamentals Cooling Tower Fundamentals Cooling Tower Fundamentals is devoted to the implementation of water cooling systems which satisfy design and environmental requirements with sound engineering and responsible cost Over 100 pages devoted to design components usage and testing First published in 1967 Fundamentals has evolved to one of the most popular cooling tower reference guides available Now you can own the latest edition for free Contact your sales representative for a copy or download at spxcooling com Cooling Tower Fundamentals gt Marley 1 800 462 7539 61 Maintenance Service Inspect General Condition and Operation Observe Operation of Mechanical motor fan and drive mechanism Makeup valve if equipped Inspect for unusual noise or vibration Inspect and Clean Air inlet PVC drift eliminators Distribution basin nozzles and collection basin Fan motor exterior Check Collection water basin level Blowdown adjust as required Geareducer Drive if equipped Check for loose fasteners including oil drain plug Check for repair oil leaks Check oil level Change oil Make sure vent is open Check driveshaft or coupling alignment
33. minishes some of the initial peak torque impulse realized during hard starting High torque ratings allow the Comp DS design to accommodate high motor power ratings in an expanded speed range Easily interchanged Owners with Marley 301 stainless steel driveshafts or Series 400 composite tube driveshatts may directly replace their existing assembly with the Comp DS series 49 Soffork MC Coupling Quiet operation No axial separation of hubs Corrosion resistant materials and coatings Simple to install Balancing not required at 1800 rpm Fast and easy flexible element replacement Accommodates misalignment in the angular and parallel directions as well as end float Flexible element tire type coupling COUPLING designed specitically for cooling tower applications Couplings consist of two cast ductile iron electro galvanized hubs and clamp rings with stainless steel fasteners CLAMP RING CLAMP RING BOLT Outstanding vibration dampening characteristics Shock load cushioning ideal for VFD use High degree of flexibility to accommodate misalignment FLEXIBLE ELEMENT gt Marley Buy Marley Parts com 50 Cooling Tower Duty Motors Three part corrosion resistant epoxy paint coating on exterior and interior surfaces V ring slingers on both end shields plus an external water slinger flinger m Service factor 1 25 up to 100 hp 1 15 from 125 hp and up Automatic drain plu
34. nitized carbon tiber flexible elements with slip tit stainless steel hubs are easier to install and align than others using steel torque elements Comp DS driveshafts are designed for fans up to 10 meters in diameter and for motors up to 300 hp Marley s Comp DS composite driveshafts offer the following benefits Low Maintenance Ease of Installation The tull floating design has no intermediate couplings or bearings The simple hub design and corresponding unitized tlex elements require less labor to install and maintain than previous designs gt Marley Carbon fiber unitized flexible element Lightweight The lightweight permanently bonded tube and flange assembly is easily handled by technicians without the need for lifting equipment The reduction in rotating mass also results in lower radial loads on motor and Geareducer bearings Modern Construction Robust composite design is comprised of high strength fiberglass and or carbon fiber reintorced tubes in a tough epoxy matrix along with fiberglass flanges and urethane encased carbon fiber flex elements Additionally the quantity of components and hardware is minimized 1 800 462 7539 UV and Corrosion Resistant Materials All materials are specially selected for cooling tower duty and are constructed to provide maximum protection against corrosion and UV attack Performance The composite tube prevents transient start up vibration and di
35. o profits Marley Temporary Cooling Solutions is geared entirely toward making your performance our priority including a fleet of ultra efficient induced dratt towers and regional support teams who are on the ground and ready to move gt Marley 1 800 462 7539 59 Aftermarket Services Repair and reconstruction Inspection and condition reports Performance testing Maintenance plans Whether investing in a new plant or Operating an existing system cooling tower maintenance is critically important to operational efficiency equipment longevity and regulatory compliance Regular service by experienced teams helps ensure your cooling system and your bottom line is not compromised by unexpected failure giving you the peace of mind to focus on your business For many older towers reconstruction is a cost effective alternative to replacement Our reconstruction experts work with our engineering statt to make old towers as good as new if not better Our reconstruction specialists have been trained to analyze the condition of your cooling equipment and its capability to be successtully repaired rebuilt or upgraded Your SPX Cooling Technologies sales representative can arrange an inspection of your cooling system gt Marley Let our cooling system experts help your maintenance experts We can contract with you to provide as much hands on maintenance assistance as you need Perfor
36. ogies is the only 9 30 RATIO 11 18 RATIO major manutacturer whose gearbox is designed uniquely for cooling tower duty Since SPX warrants not only its Geareducer but the thermal performance of the cooling tower as well design and manutacturing is taken very seriously This has resulted in a history of trouble free operation unequalled in the cooling tower industry The Marley Series 22 3 was up to 4 dBA quieter than the al Adan Amarillo Series A22 Both Sound measurement testing of cooling products having the same tower gear speed reducers was conducted gear ratio by National Technical Systems NTS in The Marley Series 32 2 was 1998 Concurrent testing was conducted 7 to 10 dBA quieter than the on Marley and Amarillo gear speed Amarillo Series A32 Both reducers in accordance with SAE J2101 products having the same at various speeds and loads gear ratio Power SOUNO levels were measured for These sound levels were recorded under Marley gear speed reducer products in fully loaded conditions both comparison groupings tested gt Marley 1 800 462 7539 39 Sprag Clutch Backstop The Marley integral Sprag Clutch Backstop is custom designed and configured specifically for a Marley Geareducer with input shaft diameters of 2 375 and 2 625 Also referred to as a sprag clutch anti rotation device these units are designed to prevent reverse rotation of the fan Geareducer and motor Designed specifically for use with the current 32
37. ong service Marley HP7000 The hollow blade is designed Close up views of other manufacturer and with a deep section airfoil making Marley HP7000 fan blade samples after 300 the HP7000 strong yet light and hours in the same erosion test chamber easy to handle Buy Marley Parts com 46 Series 400 Driveshaft Low maintenance Easy to install Easy to align Long service life Corrosion resistant Easily interchanged Series 400 carbon fiber driveshafts provide a lightweight low maintenance alternative to stainless steel driveshafts Marley neoprene flexible bushings are easier to install and align than others using stainless steel torque elements Series 400 driveshafts are designed for fans up to 10 meters in diameter and for motors up to 300 hp The Marley Series 400 carbon fiber driveshafts offer you the following benefits Marley Low maintenance No intermediate couplings or bearings You realize extensive savings in maintenance costs The yoke and flange coupling design featuring flexible bushings has been proven for more than 30 years on the Marley Series 301 driveshaft This system is more tolerant of misalignment with lower thrust forces transmitted to motor and Geareducer bearings than conventional driveshafts Easy to install easy to align One piece design eliminates hard to reach intermediate bearings Installation requires fewer steps The tube and flange is lightweight easily handled by
38. ooling tower seem louder to anyone nearby Hotel guests or residential neighbors shouldn t have to contend with a cooling tower tan cycling on and off at night 44 HP7i Fan True twisted airfoil design Fiberglass vinyl ester laminate Single piece construction Heavy duty steel hub assembly 72 through 168 diameter Stainless steel hardware standard Marley HP i fans are designed specitically tor cooling tower applications offering distinct advantages over other types of fans The Marley FlareTip blade enhanced for low sound operation delivers maximum air flow and pressure capability at reduced speed gt Marley The HP 7 1 blade is a single piece composite design ensuring structural integrity Fan blades with bolted or glued connections between the blade shank and airfoil section introduce an additional mechanical joint under stress The one piece composite design ensures the integrally molded leading edge will not come off or Tal and the blade will handle the toughest cooling tower applications 1 800 462 7539 The skin of the HP 7i is made with top quality fiberglass reintorced vinyl ester that is infused with pigment Tor even distribution across the laminate There are multiple layers of surtace veil on the blade surface leading to superior UV protection compared to fans with only a painted exterior Blades attach to the fan hub using a heavy galvanized iron ring integrall
39. ounterflow design Withstands foot traffic Unique extruded heat fused polypropylene design SPX s patented TrickleBloc clog resistant splash fill is comprised of extruded polypropylene cylinders heat tused to form blocks of splash media The open weave of the vertical cylinders provides even water flow and promotes thermal efficiency The lattice design promotes splashing to help facilitate self cleaning gt Marley Buy Marley Parts com 30 ERC GridLoc Splash Fill Support grid and snapped into place Marley GridLoc splash till support is a polypropylene injection molded support for use in crosstlow towers The GridLoc design has a pair of integral opposing downward sloping splash bar grips attached to the vertical strands in each window to secure splash bars The lower horizontal strand has a short pair of vertical nubs to center splash bars and provide a nonabrasive support that eliminates the need for bench supports gt Marley Splash bars are easily inserted into the The GridLoc design has a molded in shelf support at the top of the grid for attaching the grid to the structural members The grid can be either nailed or screwed to the support member to avoid movement of the grid in the horizontal plane 1 800 462 7539 The typical GridLoc arrangement will be in 4 x 6 bays with bars parallel to air flow The nominal window opening for bar spacing is 4 horizontal by 8 vertical
40. re are no special valves to open or close The nozzle assembly is attached to the header lateral using a unique design EPDM grommet that is inserted into the pipe the entire assembly is attached with stainless steel strapping Water Distribution Legacy Nozzles Legacy Product Nozzles Cooling Tower Know How In most cases it makes sense to replace older design nozzles with modern current designs gt Marley Buy Marley Parts com HC Crossflow Valves The HC Valve has inspired many dr imitators only Marley can offer r you the original Cast iron body Cast iron operating bar Cast iron locking bar Stainless steel stem Neoprene joint gasket and set for floating valve disc Economical compared to a separate valve and elbow Standard HC Valve i Y Capacity GPM Valve Size 5 FPS 10 FPS 6 Diameter 425 850 8 Diameter 750 1500 10 Diameter 1200 2400 12 Diameter 1750 3500 14 Diameter 2350 4700 Flanged HC Valve 16 Diameter 3000 6000 ms o 18 Diameter 4000 8000 20 Diameter 5000 10000 HC valve body proportions and the The valve closure disc has a machined The greatly simplitied design ensures arrangement of internal parts provide lip which closes on a heavy neoprene long trouble free operation with no a low discharge velocity and confine gasket avoiding maintenance ot costly repairs or maintenance splash resulting in low pressure drop expensive met
41. robe installed in a Marley NC crossflow cooling tower Stainless steel 303 conductivity probe tips are suspended trom a PVC conduit box using flexible wire providing a means to monitor water level when used with a Marley LLC control panel Each probe is furnished with 20 feet of wire for connection to the Marley LLC control panel If longer wire is required the probe wire may be spliced in the field Each probe is furnished with a cord grip which may be loosened allowing probe height adjustment Adjustable electrode probe system stilling chamber removed Buy Marley Parts com 56 LLC Water Level Control Panel LLC Control Panel Features NEMA 4X Fiberglass Enclosure Mounting flanges located top and bottom Outdoor rated Stainless steel continuous hinge Swing out lid with stainless steel clamps Lock off capabilities 14 high x 12 wide enclosure for configurations up to 4 cards 18 high x 16 wide enclosure for configurations up to 6 cards Electrical Components Main breaker disconnect HAND OFF AUTO selector switch for manual fill control when makeup card is used Output contact for makeup card is internally powered with 120 VAC for use by customer User terminal points for connecting field devices e g solenoid water level probes and alarm devices Terminal strip raised for easy access Wiring diagram and User Manual secured in literature pocket inside the panel door Built to UL and CUL standar
42. rosion resistant PVC extrusions which are supported by FRP fiberglass reinforced polyester grids gt Marley The rounded upper surface of the Till bars and the smooth surface finish facilitate cleaning FRP fill grids are extremely inert and tough Each fill bar is firmly attached to the FRP grid to prevent premature wear on either the grid or the Till bars The fill bars are designed to prevent sagging even after prolonged exposure to a cooling tower environment Alpha fill is a direct replacement for many types of wood lath Till The FRP grid can be manufactured to fit virtually any cooling tower regardless of its age or manufacturer 1 800 462 7539 25 HE HED nen Mesa Crossflow Splash Fill High performance Perpendicular and Parallel configurations Easy cleaning Exceeds CTI Standard 136 for strength flammability and impact Marley Mesa splash till advances the state of the art in cooling tower splash fill The enhanced thermal performance of Mesa fill increases cooling tower capacity in most cases Variable fill bar spacings provide the required thermal performance with the minimal fill material and installation time Mesa fill is installed parallel or perpendicular to the air flow depending on thermal performance requirements or existing cooling tower configuration gt Marley Mesa fill bars are extruded of corrosion resistant PVC polyvinyl chloride manufactured at SPX s Kansa
43. rue airfoil blade designed standard equipment on various Marley specifically tor cooling towers offering product lines All H3 tan assemblies efficient quiet operation and long incorporate machined aluminum hubs service life Available in 54 through with stainless steel hardware All H3 216 fan diameters fan blades are adjustable in pitch to take full advantage of rated horsepower or to compensate for unusual job site restrictions gt Marley Buy Marley Parts com 42 X7 Fan True airfoil quiet design Lightweight extruded aluminum alloy m Infinite pitch adjustment Galvanized ductile iron hub m 66 through 168 diameter Marley X7Fan with U Style hub The Marley X7 fan is designed for induced draft cooling tower applications offering distinct advantages over other fan designs The Marley FlareTip blade enhancement provides increased performance overcoming tip clearance losses aiding the movement of air next to the fan cylinder The blade end caps are injection molded impact resistant polypropylene with a section on the upper surface to allow for consistent fan pitch setting The wide chord blade design is well suited for low noise operation as well delivering superior air flow and pressure capability at reduced speed The high performance X airfoil is one of the most efficient in the industry today Additionally all blades are match moment weight balanced allowing all X blades
44. rugations inherently establish unitorm fill sheet spacing at 0 75 MC75 fill is thermoformed trom 015 thick UV inhibited chemically resistant polyvinyl chloride PVC The flame spread rating is less than 25 gt Marley Au Ak Ki N NW I i V i N Lu V N per ASTM E 84 and is considered self extinguishing The material is extruded and manufactured to rigid specitications before forming Using Marley MC75 film fill in place of existing splash type fill in counterflow towers usually means reduced Till height which translates into reduced pumping head MC75 will also provide greater cooling tower capacity which means your current performance level will require less fan energy Buy Marley Parts com el hh d Mi T Tar AT A M4 A Y shh AA The fill pack depth air travel is variable to provide the proper heat transfer area within a single fill layer If another layer of Till is necessary for situations where additional air travel is required it will be limited to only one Limiting the number of interfaces between packs minimizes restrictions that usually cause fill clogging MC75 counterflow fill can be hung from structural members or it can be bottom supported in virtually all counterflow cooling towers regardless of a cooling tower s age or manufacturer 20 ME HD e MCR Counterflow Film Fill Vertical flute film fill Hanging or bottom support design Efficient therma
45. s plastics manufacturing facility The unique material formula used in the Mesa bar meets or exceeds CTI Standard 136 for strength flammability and impact Each bar is firmly attached to the Marley GridLoc polypropylene injection molded support for use in crosstlow towers GridLoc provides a nonabrasive support that eliminates the need for bench supports Buy Marley Parts com 26 HE HD nen S Ladder Crossflow Splash Fill High Performance High temperature capability Variable spacing Unique injection molded polypropylene design Marley Ladder fill provides highly efficient water breakup to develop excellent heat transter with low resistance to airflow The horizontal spacing is variable to meet thermal performance requirements gt Marley d BR lil ll BL A l ut H T P j i CNN h Aj i i TEE imi T ll TE op Hemi wet ee te ALTE T T H mie u l li 1 e ge Wl alia cul Zu AR KN a a J KL a E ke mik Ll LIT J TI TTT STEI WII r SN Bit TI T HTIN EE 8 a cm iy LECH IR IE WW IE i JJi ly L Baie Lal l HIR IT E E ap el rm EOT 2 N i ji fl Fil H LU j i _ E J yf falta al f E la 1 d j FET Bi At E Ladder fill can be installed in virtually Injection molded polypropylene Ladder any crossflow cooling
46. sheet spacing prevents clogging and the integral drift eliminators do not require extra frames or retainers MBX is thermotormed from 20 mil 020 thick PVC with a flame spread rating less than 25 per ASTM E 84 and is considered self extinguishing Therefore the risk of fire damage is minimal 23 HE HD en M106 Crossflow Film Fill High Performance Bottom supported fill design Integral triple pass eliminators Available with or without eliminators Easily installed as a replacement fill in non Marley products Marley M106 is a film type cooling tower Till Water flowing down the fill sheets forms a thin film on the surface of the sheets This type of Till provides much more water surface exposure per cubic foot than does splash type fill This fill offers greater cooling efficiency which translates to colder water trom present systems without an increase in fan horsepower Or this improved efficiency can be used to save horsepower and produce the same cold water temperature M106 fill is also available with highly efficient drift eliminators molded right into the Till sheets Compared with older designs these eliminators reduce water carryover drift from the tower by a factor of ten or more Reduced drift means lower water and gt Marley Ss KSS O SS SS SSS i My e ACEN SRS n lt lt WW CC SS i SAAS SN C SS SS OO a da s w d C NNN ks gt x Ze lt lt an ete N
47. sludge deposits and corrosion and a superior extended lite lubricant than normal petroleum oil gt Marley The advanced formulation of Gearlube can extend the service life of any gear box especially the System 5 Geareducer Also available non synthetic Marley Turbine mineral oil is in accordance with the most recent edition of AGMA 9005 requirements for rust and oxidation inhibited gear oils Buy Marley Parts com Cooling Tower Know How If lubricants other than Marley oils are used they must not contain any additives such as detergents or E P additives which are adversely affected by moisture and could reduce the service life of the Geareducer 38 Geareducer Sound Levels More Than Quiet Although the primary function of a cooling tower speed reducer is to reduce 94 the speed of the driver usually an electric 90 motor to a speed which is conducive 87 to good tan performance it must satisfy 2 Se other criteria as well For example it must provide support for a large fan withstand Gi 2 the shock loads imposed at start up and during subsequent speed changes and anchor the fan against lateral movement S We in response to rotational forces Plus it e must contribute as little as possible to 2 power transmission losses as well as the generation of noise MARLEY AMARILLO MARLEY AMARILLO 22 3 A22 32 2 A32 SPX Cooling Technol
48. ssure drop in an aerodynamic durable design gt Marley DF381 is easily adapted to any tower s configuration To accommodate for various fill heights and or desired duties DF381 may be installed in multiple layers DF381 fill is thermoformed from 020 thick UV inhibited chemically resistant PVC polyvinyl chloride The material is extruded and manufactured to rigid specifications before forming at one of Marley s plastics facility In service now for over ten years at numerous installations throughout Europe DF381 is now available globally for any counterflow cooling tower regardless of a cooling tower s age design or manufacturer 1 800 462 7939 Cooling Tower Know How Continuous water temperatures for most PVC Film Fills should never exceed 125 F Special high temperature PVC formulations and thicknesses are available for water temperatures as high as 165 F 15 ME HD nn MVC20 Counterflow Film Fill High performance low clog design Bottom supported Requires minimum number of supports Marley MVC20 anti fouling film type Till consists of thermoformed corrugated sheets made of rigid polyvinyl chloride PVC impervious to decay fungus and biological attack The sheets are bonded to torm modules which can be dimensioned to Tit any application gt Marley Marley MVC20 fill combines properties related to a media s ability to allow substances to migrate through it
49. t chemicals Fasteners hidden by successive interlocking panels gt Marley BL EL li li a i sH l i k tn gt a d D Sp ag D s am EN WA A 1 800 462 7939 Your hot water basin can be a rugged light weight basin of Marley DuraLast fiberglass composite material Pultruded fiberglass composite is an ideal material for the wet corrosive cooling tower environment It s strong and lightweight Yet it will not corrode trom chemical exposure or moisture and it resists deterioration from sunlight Our experience with composites dates back to the early 1950s Now the pultrusion process produces a product with definite predictable and measurable performance Extensive laboratory university and field testing for long term effects of detlection bending shear buckling and temperature has enabled us to simulate and evaluate DuraLast s performance 13 HE HD nn DF254 Counterflow Film Fill High performance low clog design Bottom supported Requires minimum number of supports Log configuration Marley DF254 is a film Till system designed to signiticantly reduce the risk of biological fouling without sacrificing high performance heat transfer DF 254 is a bottom supported low clog log Till configuration Open angular cross corrugations allow debris and biological growth foulant to pass while providing maximum surface area and turbulence to develop efficient h
50. t protection Field selectable bypass mode of operation UL Listed Marley tan motor Variable Speed Drive systems are designed to combine absolute temperature control with ideal energy management The cooling tower user selects a cold water temperature and the drive system will vary the fan speed to maintain that temperature Precise temperature control is accomplished with tar less stress to the mechanical equipment components The improved energy management provides fast payback to the user gt Marley IUIIUUUU SS The standard VFD requires a speed reference input signal from a remote source such as a building automation system or RTD with 4 20mA transmitter VFD will accept a 4 20mA O 20mA or 1 10VDC signal Speed may also be controlled with the onboard keypad Marley Premium Variable Speed Drive features Automatic Bypass circuit standard This feature transters the fan motor trom the drive to a temperature modulating bypass contactor if the VFD faults out on specific fault parameters allowing continuous operation of the tower 1 800 462 7539 kg Se a mm KN a Ty De Icing function standard with auto canceling timed run of 20 minutes maximum The Marley Premium VFD drive is not intended to be controlled by building or process automation systems No external controller required Included is an integrated temperature controller and RTD sensor
51. to be interchangeable without the need to rebalance the entire fan assembly gt Marley 1 800 462 7539 Each blade is secured to the hub with two stainless U bolts that allow blades to be easily rotated to adjust desired pitch angle delivering precise utilization of fan horsepower Superior strength excellent quality light weight and outstanding performance makes the X7 fan an outstanding choice for cooling tower applications and best of all it s a Marley fan 43 Ultra Quiet Fan True airfoil quiet design FRP blades Infinite pitch adjustment Machined aluminum hub 84 through 168 diameter Stainless steel hardware standard The Marley Ultra Quiet Fan represents the top of the line of new generation in super quiet fans the FRP blades have been developed to meet the most stringent noise limitations The fans permit variable pitch adjustment and feature a simplified hub design gt Marley Common Applications for Ultra Quiet Fans Hospitals Noise concerns may be paramount near medical facilities where quiet and rest are necessary Universities and Oftice Buildings Whenever HVAC equipment is near people unwanted noise may be a concern For example conducting a meeting or teaching a class in a room with cooling equipment outside is an unwelcome distraction Buy Marley Parts com Hotels and Residential Areas At night ambient noise levels are lower which may make a c
52. tower regardless fill is extremely inert to chemical of its age or manufacturer reaction Ladder fill is capable of 150 F water temperature operation 1 800 462 7539 27 HE HD nen Omega Crossflow Splash Fill High performance Perpendicular and Parallel configurations Easy cleaning Exceeds CTI Standard 136 for strength flammability and impact Marley Omega splash fill advances the state of the art in cooling tower splash fill Enhanced thermal performance of Omega Till increases cooling tower capacity in most all cases Variable fill bar spacings provide the required thermal performance with the minimum amount of Till material and installation time Omega fill is installed parallel or perpendicular to the air flow depending on thermal performance requirements or existing cooling tower configuration gt Marley Omega Till bars are extruded of corrosion resistant PVC polyvinyl chloride manufactured at SPX s Kansas plastics manufacturing facility The unique material formula used in the Omega bar meets or exceeds CTI Standard 136 for strength tlammability and impact Each bar is firmly attached to FRP or stainless steel fill grids with unique injected molded polypropylene benches designed to prevent premature wear on the Till bar and the grid Buy Marley Parts com Omega bar s classic arch shape enhances structural characteristics which prevents sagging even after prolonged exposure to
53. unted H O A selector switch Speed selector switch for two speed applications Adjustable motor overload User terminal points for connecting field devices Two wire vibration switch interface for starter shut down if vibration switch trips 1 N O motor overload trip contact for feedback to customers alarm system or BAS Cold water temperature thermostat connections for starter ON OFF control Wiring diagram laminated and mounted on inside of door UL and CUL listed assembly gt Marley NEMA 3R outdoor cabinet with the following features Rain shield Mounting flanges located top and bottom Piano hinge Lock off capabilities Hex head screw type hold downs for door Warning labels optional NEMA 4X fiberglass cabinet for corrosive locations Buy Marley Parts com Options Pilot lights Status contacts for BMS interface Solid state temperature controller with readout display Integrated basin heater controls with temperature probe and heater contactor Integrated water level controls Make Up Hi and Lo alarm contacts GFI power receptacle for trouble light and power tool Factory installed and wired control panel on select towers DE ICE reversing circuit for two speed applications only 52 Variable Speed Drive 6 Pulse PWM drive with IGBT switching and integrated bypass design Main circuit breaker disconnect with thermal and short circui
54. y resistant polyvinyl chloride PVC The flame spread rating is less than 25 per ASTM E 84 and is considered selt extinguishing The material is extruded and manufactured to rigid specifications before forming Log packs are nominally 12 in air travel height and 12 deep Normal pack length is 72 but packs are available up to 120 Maximum air travel height is 48 Packs have a 2 staggered edge on the air inlet side of the pack that enhances performance and air distribution 1 800 462 7539 Staggered edge 17 Re FB20 Counterflow Film Fill Vertical flute film fill Efficient thermal performance Low clog design Low maintenance Withstands foot traffic Resists erosion from water spray Marley s FB20 clog resistant film fill is constructed of fire retardant PVC sheets bonded to form blocks of cooling media The surface microstructure facilitates air water mixing and increases the surface cooling area The offset vertical flutes provide directional changes in air and water flow to increase cooling and promote thermal efficiency while substantially reducing the occurrence of fouling gt Marley Se a N EN BN bh WA Lak WNN N koka RN nk NNN i vg H T K wem ANN U Continuous water temperatures for most PVC Film Fills should never exceed 125 F Special high temperature PVC formulations and thicknesses are available for water temperatures as high as 165 F Buy Mar
55. y molded with each fan blade By loosening the hub attachment hardware blades can easily be rotated to achieve desired pitch permitting maximum utilization of fan horsepower 45 HP7000 Fan True twisted deep airfoil design Fiberglass reinforced vinyl ester laminate Single piece construction Heavy duty dual plate heavy galvanized steel hub assembly 168 through 394 10 meter diameter Stainless steel hardware standard Marley HP 7000 fans are designed specitically for industrial cooling tower applications offering distinct advantages over other types of fans The Marley FlareTip blade enhancement provides increased performance overcoming tip clearance losses aiding the movement of air next to the fan cylinder The wide blade design is well suited tor low sound operation delivering superior air flow and pressure capability at reduced speed The skin of the HP 7000 is made with top quality fiberglass reinforced vinyl ester that is infused with pigment for even distribution across the laminate There are multiple layers of surface veil on the blade surface leading to superior UV protection compared to fans with only a painted exterior gt Marley Constructed in one continuous piece with a consistent moment weight HP 7000 blades are inter changeable without the need to rebalance the tan assembly A nylon leading edge erosion barrier is molded into each blade to ensure l

Download Pdf Manuals

image

Related Search

Marley Cooling Tower Parts Reference Guide marley cooling tower model numbers marley cooling tower model number lookup marley cooling tower fill replacement marley cooling towers official site marley cooling tower fan cylinder marley cooling tower fill marley nc cooling tower user manual marley cooling tower serial number lookup marley cooling tower prices marley water cooling tower used marley cooling tower marley cooling towers for sale marley cooling tower rep locator marley nc series cooling tower marley cooling tower company marley cooling tower near me marley av series cooling tower marley cooling tower rep near me marley cooling tower oil