1. System Operation System status Disarmed a wd _ System status received at 06 04 2009 17 14 50 local time at control system bbcctest Logged in SYSTEM READY REFRESH STATUS You can arm and disarm the system using the Arm Disarm drop down box upper right part of the page or using the buttons in the System Operation Area S It is important to note that when you are using the Web application the system is armed with the programmed delay 08 o The Web Application allows you to arm and disarm your system via the Web Application using any of the available arming methods e On the Status Bar below on the page you can see the current status of the system in our example it is Disarmed and System Ready which means that the system and all the detectors are working properly and there are no events to report It is possible to check if there were alarms in the system 4 4 Web Application Settings System Users and Codes aletas ete eee tog History View a Wet of system events Mal prune in your home Print or gave tire log file Pom M Automation Wiew streaming vitso via IP cameras Manage contacte for system event Web contral over your name installed in your home notification allowing you anal your aggliances Control automated fami To abvsavs stay informed devices and schedule daly activation Wieleome lo your web weer application a comprehensive i
2. To initiate Remote Firmware Update o From the Programming menu select Service Remote Software Update 710 a 24 hours time window is opened during which the Remote Firmware Update may be performed IP Display When using Ethernet connection you can view the LAN IP address of the Control System i e the address that your home router has assigned to the Control System To display the IP Address e From the Programming menu select Service IP Display 711 the LAN IP address of the Control System is displayed 46 Appendix A Menu Structure Ras S Es 1 Cancel Report 2 Bypass Zones 3 Home Automat 4 User Codes 5 Telephone 6 Event Log 8 HA Schedules 9 Programming 1 Bypass Unbyp 2 Unbypass All OA 1 View Log 6 GSM Signal 7 Version 8 Enable Pog 9 Global Chime 10 SW Update 11 IP Display 47 Cz 51 Follow Me Cv 2 1 Edit Code 1 Set Time 2 Set Date 1 Play Message 2 Record Message 3 Delete Message 1 WL Siren Test 2 Siren Test 3 Interface Test 4 Walk Test 5 Snapshot Test 1 TX List 2 TX Test 3 RF Link Test 4 ENV RSSI 2 Off Time 3 Schedule Legend 4 Installer code required of Master code required Appendix B Glossary 24hr Zone Armed Arming Keys Bypassed Zone Cancel K
3. gt Press the relevant button on your keyfob see Keyfobs the exit delay begins to count down At the end of the exit delay the system is armed Forced Arming Forced arming enables you to arm when the system is not ready For example if a door protected by a magnetic contact is open you may arm the system on condition that the door will be closed by the end of the Exit delay If the door is still open after the exit delay expires an alarm is generated Forced arming is available only if the option is enabled in programming Forced arming may be enabled for specific zones or for the entire system Instant Arming Instant arming is a feature that allows you to cancel the entry delay after Part or Perimeter arming the system For this feature to function it must be enabled in programming by your installer To instantly arm the system 1 Check if the system is ready to arm 2 Press the Part or Perimeter arming key on the keypad and enter your user code if One Key Arming is disabled 3 Press and hold down on your keypad until the message Instant Arming OK is displayed 4 Press V the entry delay for the current arming period is canceled Supervised Arm Supervised Arm is an optional feature designed to supervise intrusion detector activity before you arm the system If supervised arm is enabled in programming and the system has not received a transmission from a detector for a certain amount of time all arming metho
4. Do not include the symbol in the descriptor as the system regards any text after this symbol as part of the command The SMS Command Descriptor is optional but you must still enter the before the user code SMS Confirmation Message Format After an SMS command is executed by the system if programmed by your installer a confirmation message may be returned to your mobile phone This message includes the HA unit s descriptor and the command that was sent The following example shows the confirmation message you receive for the sample command from the previous section B O I L E RH ON 31 6 5 Scheduling not relevant to PGM The Scheduling feature allows you to set an On and Off time for each HA unit At these times the system automatically switches the HA unit on and off You can also choose the days of the week that the schedule is active On Time To edit an HA unit s On Time From the main menu select HA Schedules 8 Select an HA unit From the HA unit s sub menu select On Time Enter a time HH MM Press Y when the desired setting is displayed Off Time To edit an HA unit s Off Time 1 From the main menu select HA Schedules 8 Select an HA unit From the HA unit s sub menu select Off Time Enter a time HH MM Press Y when the desired setting is displayed Weekly Schedule To program the days of the week that the schedule is active IAS LIO A a a dul 1
5. 1 From the Service menu select Messages Record Message 7022 2 Press V to start recording the message 3 Record your message The message may be up to twenty seconds long 4 Press V to stop recording the message is automatically played back and OK is displayed 5 Press Y to save your recording To delete a message 1 From the Service menu select Messages Delete Message 7023 OK is displayed 2 Press V the message is deleted The Record and Play options can also be accessed via a convenient shortcut without needing to enter a valid user code To access the Record Message option from Standby mode press then X To access the Play Message option from Standby mode press a then y 41 Siren Tests To test the external wireless siren o From the Service menu select Test and then WL Siren Test 7031 the wireless siren is sounded briefly To test the built in siren o From the Service menu select Test and then Siren Test 7032 the built in siren is sounded briefly Interface Test The Interface test enables you to check if the speaker LEDs and LCD are functioning correctly To test the system interface o From the Service menu select Test and then Interface Test 7033 a short sequence of chimes are sounded from the speaker all LEDs flash and the LCD is tested on all connected LCD keypads Walk Test Walk Test mode enables you to test all the detectors registered to your system without trig
6. Intermittent On Off Yellow System Trouble in addition to AC loss Low Battery 8 It means If the Arm Status LED iS Off The system is disarmed On Green The system is armed Flashing Red An alarm has occurred Alarm indication is cleared the next time you arm the system or view the relevant event in the event log TS Alarm indication is not displayed after a silent panic alarm E System Trouble Indication In the event that the system detects a trouble condition System Trouble appears on the display To identify the problem scroll through the trouble list by pressing v Scrolling the trouble list also silences system trouble tones that may be sounded if enabled in programming When the trouble condition is restored it is removed from the system trouble list For detailed information on system messages see Arm Status Indication and Fejl Henvisningskilde ikke fundet 2 2 Alarm Sounding Patterns The following table summarizes various alarms sounded by the control system Alarm Alarm Sounding Pattern Description Burglary ON continuously Fire ON ON ON 1 5 second pause ON ON ON Gas ON ON ON ON short bursts 5 second pause ON ON ON ON Medical ON continuously only applicable for Medical alarm from zone Flood 4 rapid tones sounded once per minute same as Trouble tones Environmental 4 rapid tones sounded once per minute same as Trouble tones 2 3 Keyfobs The C
7. select Clear Log From the Service menu select Set Time Date Set Date 7012 5 v buttons 5 Interface Test E A Description Use the arrow buttons to scroll through the options and press v Enter the main menu by pressing vV and entering your user code Using the arrow buttons navigate until you reach Event Log and press v Using the arrow buttons navigate until you reach Clear Log and press v The same as above only this time you are navigating through three menu levels The shortcut to a specific menu item from the main menu In this case this is the shortcut for Set Date These appear in the procedures as an additional aid to menu navigation A shortcut to a specific item in a sub menu For example 5 is the shortcut to Bell enable disable in the sub menu that is opened once you have selected the detector you want to program Indicate buttons that appear on the keypad O O The text that actually appears on the LCD display italics Note Important caution please pay attention 1 2 Security System Components Your security system is made up of a Control System various detectors and a number of optional peripheral devices This section explains the role of each component in your system Control System The Control System is the brain of the system It communicates with all the devices connected to the system For example in the event of a burglary a detector sends a signa
8. audio Chimes sounded by the Control System s internal or external siren Tones sounded by the system to indicate a trouble condition Two Way Audio abbr Transmitter abbr A service feature that lists all the system s registered transmitters their last recorded status and signal strength A service feature that displays the source of the last received transmission U The restoral of a bypassed zone to its original state A four digit code that grants access to certain system functions such as arming and disarming the system A user code that enables Two Way Audio communication W A mode that enables detectors to be tested without generating an alarm Software that enable installers or service providers to operate and program the system from a PC either on site or from a remote location Intelligent two way wireless keypad with large LCD display that serves as an additional user interface of the Control System Z A protected area within the security system See Bypassed Zone 51 Electronics Line 3000 Ltd Limited Warranty EL and its subsidiaries and affiliates Seller warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller Seller cannot guarantee the performance of the se
9. control system bibsediest E oopa qt Meses ZU TER Rey 2 Press Add new to add email addresses or cellular telephone numbers for the alert messages HOME ARRAMDISA R A HISTORY VIDEO AUTOMATION ll Ar ALERTS ADD NEY CONTACT a Contact Name Email Address Cellular Phone E Alert Language Enqlish UkK EXA E ENS ArmDigarm O O Fire O O Burglary System status received at 0304 2005 12 01 40 localtime at control systemi a Lagaped in SYSTEM REASEY 3 In the Contact Name field enter the name of the contact to receive alerts 4 In the Email Address field enter the email address for email alerts 5 In the Cellular Phone field enter the cellular phone number for SMS alerts 6 To start receiving the events messages in the area below select the checkboxes according to the event type and message type you prefer email or SMS e Test the alerts you have programmed by clicking the Test button on the Alerts page near the newly added alert 27 4 5 Event Log History The History page enables you to view the system s event log The events are arranged in a table that offers the advantage of allowing you to view a large number of events at once In addition to viewing the event log you may also save the log to a file HTML PDF or RTF or print the log For further details on how to use the Web Application refer to the Help menu included in the application To view
10. during certain alarm conditions serving to warn you and ward off intruders 1 3 System Monitoring When an event occurs within the system the Control System sends a message to your monitoring service describing the exact nature of the event This enables the monitoring service to take the required action System monitoring can implement either regular telephone or cellular communication A detector detects The Control System is alerted gt An alarm is generated and the monitoring service is notified N Remember that no security system can prevent emergencies This system is only intended to alert you in case of an emergency and should not take the place of prudent security practices or life and property insurance 1 4 Home Automation An optional expansion module can provide you with the ability to control up to 16 individual electrical appliances or lights using the front panel keypad wireless keypads or keyfobs Additionally each appliance can be programmed to be turned on and off automatically according to various schedules and system status conditions 1 5 Self Monitoring In addition to the ability to report to a monitoring service the system can also send you and other users notification when an event occurs This may be in the form of vocal messages played over the telephone or if your system supports cellular communication you can receive information on system status via SMS If an alarm occurs on
11. e Press and hold down the Service Call key for a few seconds Ln If using Simplex mode the call is connected in Listen mode see Simplex Mode 7 3 Two Way Audio after an Alarm In the event of Burglary Fire and Emergency alarms the Control System is able to report the events and then stay on the line This allows the monitoring service to verify the alarm or provide assistance in the event of an emergency 7 4 Two Way Audio Follow Me This feature causes the Control System to call you in the event of an alarm so that you may check your family and home When the Control System calls you will hear two short tones when you pick up the phone Press 2 on your telephone to answer the call If you press 9 to answer the call the Control System simultaneously cancels the siren E when you answer the call If using Simplex mode the call is connected in Listen mode see Simplex Mode 7 5 Simplex Mode It is possible that the Two Way Audio features on your system are programmed to operate in Simplex mode Simplex mode means that one party may speak while the other party listens If using Simplex mode the call is connected in Listen mode In Listen mode the microphone on the Control System is turned on so that you can listen in If you want to switch to Speak mode press 1 on your telephone In Speak mode the microphone is turned off and the speaker is turned on so that you can speak to the person on the other end
12. of the line If you want to switch back to Listen mode press 0 on your telephone 35 8 Advanced System Operation Besides the basic functions described in the previous chapters you can access additional functions via the menu This chapter describes these functions and the menu navigation procedure Menu Navigation Using the LCD keypad on the front panel you can navigate through the menus using the menu navigation keys a v and make simple yes no decisions using the Y and X keys The availability of menu items depends on the user code that you used to enter Menu mode Some menu items are limited to the Master code only User 1 Certain menu items such as system programming functions are not intended for the user and can only be accessed by the installer The following example explains the procedure for Event Log viewing Master code access only 1 Press Y to enter Menu mode 2 Enter the Master code the first menu item in the main menu Cancel Report is displayed 3 Press v until 6 Event Log is displayed 4 Press V to enter the Event Log menu 1 View Log is displayed 5 Press Y to choose the displayed item Press X if you do not want to choose the displayed item Pressing X also takes you back to the previous menu level E Menu mode automatically terminates two minutes after the last keystroke Throughout this chapter we have tried to include all of the system functions using a similar structure and ord
13. one of the three arming methods One key Arming is an option that is programmed by your installer If this option is disabled you must also enter a user code when arming 10 Service Call Button The Service Call button enables you to contact the monitoring service and talk to an operator 9 To initiate a service call press and hold down the Service Call key for a few seconds Vocal Message Recording and Playback LCD front panel allows you to record a short message that may be played back later by another user see Service Menu Message Center Cy OFF followed by the unit number 01 16 or 30 31 for PGM enables you to control lights and appliances in your home activate and deactivate the PGM output Pressing one of the Home Automation keys s8 Pressing both Home Automation keys simultaneously generates an SOS panic alarm System Status LEDs The System Status indicators provide essential information on the status of the system such as arm disarm alarm and power failure conditions If the OK LED is It means Off Both AC and Battery power are disconnected On Green System Power status is OK and there is no System Trouble Flashing Green Open Zone Check that the windows and doors are closed and no movement is detected by the detectors within the protected area On Yellow System Trouble Flashing Yellow slow Battery low from the Control System or transmitters Flashing Yellow fast AC loss
14. system accordingly to suit different circumstances aT D Full Arming Part Arming Perimeter Arming Full arming activates the entire Part arming enables you to Perimeter arming enables you system This arming method is arm a section of your home to activate the perimeter zones used when you intend to leave while remaining on a different the windows and doors of your home leaving the part of the premises your home enabling you to premises empty move freely within the protected area E Certain detectors such as smoke carbon monoxide gas and flood detectors are always active regardless of system status 3 2 Arming the System Before arming the system check that all doors and windows are secured so that the system is ready for arming If the One key Arming option is disabled in programming you must enter your p user code when arming the system from a keypad Arming with the Front Panel or Wireless Keypad To arm the system using the front panel or Wireless Keypad o Press one of the three arming keys the exit delay begins to count down At the end of the exit delay the system is armed If the One key Arming option is disabled in programming you must p enter your user code when arming the system from a Wireless Keypad or place a registered smartkey if supported against the center of the smartkey reader 15 Arming with the Keyfob To arm the system using the keyfob
15. the system s event log o On The Main Page menu click History the following page appears ARM BISARM SETTINGS HISTORY VIREO AUTOMATION LOG OFF HISTORY _Reiresh Log flast updated ai 96 04 2008 17 15 24 Local time at control panel Description onetUse nieves Reported sme za s 15 43 40 Disarmed User Nunitver 34 Remote user Yes Qofp 2008 15 43 34 Fall Arm Uer Muniber 34 Remote ussr Yes 0224 2008 18 01 23 Tamper Cantral System Failed 0204 2006 15 03 48 Tamper Control System Yes N22 16 01 28 Tamper Control System Yes 0204 2008 18 01 12 Tamper Control Systemi Yes 01 04 2009 13 02 44 Battery Restore Control Sysiem Yes fave history loa as HTML PEF TKT SAN PRIMT LO System stats receheed at 05 04 2008 17 14 50 fecal time at control system mieria zi Logge unn Bisgremevd E STENI READ REFRESH STATUS 4 6 Home Automation The Web Application allows you to control and schedule automated lights and appliances in your home The application offers a comprehensive interface that enables you to view the settings for all of your automated devices at once Additionally you can add edit or delete devices from the comfort of your PC Discuss this capability with your security service provider to determine if it is applicable to your system 4 7 Video Verification Using the 2 way wireless video verification PIR detectors installed in your home the Web Application enables you to view live video images o
16. this limited warranty or otherwise regardless of cause or origin sellers maximum liability shall not exceed the purchase price of the product which shall be complete and exclusive remedy against seller No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty WARNING This product should be tested at least once a week CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to local regulations Contacting Electronics Line 3000 Ltd International Headquarters UPGRADING Electronics Line 3000 Ltd E L EVERYDAY 14 Hachoma St 75655 SECURITY Rishon Le Zion Israel Tel 972 3 963 7777 Fax 972 3 961 6584 All rights reserved No part of this document may be reproduced in any form without prior written permission from the publisher Electronics Line 3000 Ltd 02 2012 5IN1772 52
17. DOOR 05 59Kg The transmitter s Descriptor The signal strength of the last o received transmission An abbreviation indicating the last received status of the transmitter This Means OK The transmitter is functioning correctly TA Tamper condition Notify BT Battery low your OS The transmitter is out of synchronization installer NA The transmitter is inactive E Press The left SOS button NE to display the transmitter s default descriptor 43 The second utility TX Test enables you to identify transmitters In TX Test mode each time a transmission is received a chime is sounded and the activated transmitter is displayed To initiate TX Test mode 1 From the Service menu select Transmitters TX Test 7042 2 Activate a transmitter the transmitter s details are displayed 3 When you have finished press X to exit TX Test mode Signal Strength Tones 1 1 Tone 2 2 Tones 3 3 Tones 4 4 Tones The third utility RF Link enables you to measure the RF noise levels between a selected transmitter and the system s receiver To view the Environment RF Link level reading 1 From the Service menu select RF Link Test 7043 the first transmitter on the list is displayed Ze Using the arrow buttons scroll through the list and select a transmitter 3 Press V and activate the selected transmitter e g press keyfob button The RF noise levels of the selected transmitter and the system s r
18. From the main menu select HA Schedules 8 2 Select an HA unit 3 From the HA unit s sub menu select Schedule Use keys 1 to 7 to toggle the days on and off Press To toggle Press To toggle 1 Sunday 5 Thursday 2 Monday 6 Friday 3 Tuesday 7 Saturday 4 Wednesday 5 Press Y when the desired setting is displayed 32 7 Telecontrol The iConnect Control System offers a range of Telecontrol features that provide remote access via the telephone These features include Two Way Audio remote arming disarming and siren cancel Two Way Audio You may use the Two Way Audio features to check your home in the event of an alarm or as an alternative means of communicating with members of your family For example you may wish to call an elderly person who has difficulty reaching the phone Using its Two Way Audio features the Control System automatically picks up the call and you can communicate via its built in microphone and speaker 7 1 Calling your Home You may call your home at any time in order to contact your family operate your system or check your home while you are away This feature is available for either regular telephone communication or cellular communication Making a Call using a Regular Telephone When your security system shares a telephone line with other devices e g telephone handsets an answering machine or fax it is important that the Control System distinguish between calls so that it knows wh
19. NIE re PD 35 73 Two Way Audio after anm A GEITI ciat eae rn unir 35 7 4 Two Way Audio FolloW Mesx ricota ia arder ein 35 od Omple MOE roo c 35 9 Advanced System Operation wet Rise ec hie eee Rice iii 36 MEE io 97 8 2 Zone Bypassing UnbypasSsSiNQ ooocccccccccnonncnnnccnononoconncnnonnnnncnnnnnnnnnnnrnnncnnonnnnrrnnnrrnnnnrennnnss 37 MUT eoo EU 37 Mu AAA A R 40 A O A A E a a E ad an a A 40 86 SENICE MeNe a E si tiras 41 Appendix A Menu Structure o ccoo ic eeu Na Daai 47 Abpendix B ITA ai 48 1 Introduction and Overview This user manual explains all you need to know about your iConnect security system and provides step by step instructions for all the system s user functions In addition to the explanation you will receive from your installer we urge you to read this manual so that you can take full advantage of your system s features Keep this manual in an accessible location for future reference The iConnect system has many features in order to suit a wide range of applications This manual outlines all of these features but it is likely that there are options that are not relevant to your system If you have any questions regarding the availability of the features described in the manual please ask your installer 1 1 Documentation Conventions In order to simplity the procedures that appear in the rest of this manual the following conventions are used Item Select From the Event Log Menu
20. alled on the premises For further information see Web User Application 2 The User Interface There are several methods you can use to operate the system Apart from the keypad on the front panel your system may include a number of peripheral devices such as keypads and keyfobs This chapter provides a brief introduction to each of the devices you can use to operate the system It is important that you familiarize yourself with these devices before reading the following chapters that shall describe system operation in further detail The front panel is the main user interface that provides you with all the functions you need to control your security system iConnect Control System is available with the LCD front panel configuration 2 1 Front Panel LCD Front Panel display and LEDs inform you of system arming status power failures and system trouble conditions Its alphanumeric keypad enables you to enter your user code when arming and disarming and to silence the siren in the event of an alarm eo ooo Display 0000000 0000000 0000000 o0000ooo System ooooooo 0000000 Status 0000000 indicators 0000000 0000000 o0o00o0o0oo m gt C 0000000 Arming i ma 0000000 ai Menu Keys 0000000 OOOO en OO00000 Alpha OOOO ET Keypad DOSO oo DOE 0000000 Oooooooo up de s Automation 5000000000 PGM Keys Arming Keys Three arming keys are available Full Part and Perimeter These keys arm the system using
21. amming The Enable Programming command allows a user to limit access to system programming It means that the installer or Remote Programmer can access the system only after a user with Master code provides authorization using the Enable Programming command IL gt To enable this feature contact your installer To grant access to the installer or Remote Programmer o From the Service menu select Enable Prog 708 a 30 minute time window is opened during which the Installer Code is valid or RP communication may be established 45 Global Chime Each detector can be programmed by your installer to cause the system to chime when activated This feature is active only when the system is disarmed For example the system can be programmed to sound a chime each time the front door is opened or closed The Global Chime option enables you to turn this feature on and off To enable or disable Global Chime S From the Service menu select Global Chime 709 2 Select either Enable or Disable 3 Press Y when the desired setting is displayed Global Chime can also be accessed via a convenient shortcut without needing to enter a valid user code To access the Global Chime option from Standby mode press 4 then v Remote Firmware Update The Remote Firmware Update command enables a user with Master code authorization to initiate the update from a remote PC using WEB communication Note to enable this feature contact your installer
22. and DIS a ood Eo Pe te le eto 15 Selo AMIA MODES A Neda ews gettncanasaiaurent 15 90r Amming ME OY SCM eae sett opted i AM ois x eased adandActatmene dt oU dc e etuutu nec al tA C euet e Matt uet 15 2 9 DISARMING The SV SCM ras ses ores Posed eee anos 17 3 4 Arm Status Indication and Other System Status Indication ccccccccooonnccnnnccnonannnnnnnos 17 30 Amg and oystem TONES arenen N A EI SE 18 30 mnemole Ami g and DISQ mil esise E ETE FANEN 19 4 Web User Application e Read 21 Ble MEO ONG ere Hm I Rp EA UL RUN 21 Z2 e Mb P ades ev os Qu vu uk I c Einb bti sabe adt maa tM EUR S 22 4 3 Arming and Disarming via the Web ApplicatiON ooooonccncccconnnnccnnnccnonanncnnnononnnannnonnnos 23 44 Web Application Settings ta 24 A A A AA 28 4 6 ROME AUIOMA OA A eee ee eee ee 28 4 Video VerileallOEisszesxisdayu ta ipt aped AA A a 28 5 ller iuutEt em 29 MER V scebi cuni 29 527 ISCVIOO Panic AM T 29 53 MediGablPanieAIBE seek osntted etos en Con etes Seb es 29 6 Home Automation and PM cite e ida ve coop Pe owe tein ele hice ee ies 30 Bu Keypad Contolera nen a eet ciate laa LL deti aL atc dus 30 A COMU Ol MEE T o TD OO OLD 30 A oe Poo d 31 o ME iei R M 31 6 5 Scheduling not relevant to PGM cccccccccccssseeeeeeeeeeeeeeeceeeeeseeeeeeeeeeesaeeeeeeeeessaeeeeeeeeeeeas 32 Ta A aE e e EATE 33 Te Galing your HOME arita a a aeaa PEE 33 Te S
23. ble that determine the pattern ic of these tones Arming and System Tones FULL ARMING J 7 TO EXIT System tones may be sounded by either the external wireless siren or the Control System s built in siren The following table is a summary of the tones sounded by the control system Status Tones Description Exit Delay 4 tones or continuous tones The exit entry delay is counting down Entry Delay The tones quicken when The number of tones sounded during there are 13 seconds each delay is programmed by your remaining and quicken again installer when there are 5 seconds remaining Chime 2 tone sequence similar to a A detector that has been programmed doorbell high to low to chime by your installer has been activated see Service Menu Global Chime Arm 3 tone sequence low to The system has been armed using high sounded twice any of the arming methods Arm tones are optional and are programmed by the installer Disarm 3 tone sequence high to The system has been disarmed low Disarm tones are optional and are programmed by the installer Home Rapid 2 tone sequence An automated device has been turned Automation On or Off using a wireless keypad or 18 keyfob This audible indication is programmed by your installer Status Tones Description System 4 rapid tones sounded once A trouble condition has been Trouble per minute detected press for further details For Fire Trouble Tones there is a Note Syst
24. by the system Enter the HA module number in two digits e g 03 or 30 31 for PGM Hold down this key until Service Call Dialing is displayed The number dialed for the service call is programmed by your installer Use the menu navigation keys 4 y to choose enable or disable then press v After recording a message Message Waiting is displayed until the message is played back Function Press Additional Information PLAY A then The Message Center is an MESSAGE optional feature that is included with certain versions of iConnect 2 Control System Telecontrol Commands Function Press Function Press 2 WAY AUDIO DISARM FULL ARM SIREN s CANCEL HA PGM T EXTEND CALL UNIT XX ON UNIT XX OFF for PGM XX 30 31 Table of Contents Quick Reference Guide scscsssssssssssssssssssscnsssssessesensnsennsssnansnsensensenseaeenananseneassanssensasansasseaaaaass 2 Table AIM daa 4 1 Introduction and Overview a 6 1 1 Documentation Conventions is a Gh hide idas 6 152 Secuhity System Componerse Ea A XU EO Re enemas 7 1 9 SVS MONON ecc al 8 I TOMS AUTONATION oo tied Date menle Metus add Lunes ee rutru Paine 8 EE oae xem 8 LO Teleco p O A 8 417 MocdbhMessage Anuncia lO Mercadal 9 Do VV CI PCC SS Sree E E E E I E A 9 de IDO USC INICIA mec 10 A A e E ang TTS E eds 10 2 2 Alam Sounding Palestra Anta 12 A A 12 24 Wireless Keypads aa AAA AAA 12 3 Arming
25. curity system which uses this product Sellers obligation and liability under this warranty is expressly limited to repairing and replacing at Sellers option within a reasonable time after the date of delivery any product not meeting the specifications Seller makes no other warranty expressed or implied and makes no warranty of merchantability or of fitness for any particular purpose In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty expressed or implied or upon any other basis of liability whatsoever Sellers obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct indirect or not be compromised or circumvented that the product will prevent any persona injury or property loss by intruder robbery fire or otherwise or that the product will in all cases provide adequate warning or protection Buyer understands that a properly installed and maintained alarm may only reduce the risk of intruder robbery or fire without warning but is not insurance or a guaranty that such will not occur or that there will be no personal injury or property loss as a result Consequently seller shall have no liability for any personal injury property damage or loss based on a claim that the product fails to give warning However if seller is held liable whether directly or indirectly for any loss or damage arising from under
26. date or Reiresti Stgtus to view current bypassed zones System status recoived st 05 44 2003 1901 26 focal time at contes zyatemi Buster Lage in meanman Sa SER BEAT REFRESH STATUS Change Appearance On The Main Page menu click Settings then Change Appearance to change the color scheme of your account HOME ARM DISARIM HISTORY VIDEO AUTOMATIOH LOG OFF System users and codes Web interface users and codes Change Password Zone Bypass Change Appearance Alerts Help APPEARANCE de Select Color Scheme BOXER FOREST CHERRY OPAL DUSK COO ENNEN NEN S5yelematalus received ak 06 04 2009 1801 46 floral time al control system mes Loved im eantel SOSMER HERY REFRESH STATUS 26 Alerts The Alerts page allows you to enter the details of contacts you wish to be informed when events occur in your system For example you can enter your own email address and or cellular phone number so that you will receive email or SMS notification in the event of an alarm 1 On The Main Page menu click the Alerts area The following page appears HOME ARMIDISARE SETTINGS HISTORY VIDEO AUTOMATION ARM System users and codes Web interface users and codes Change Password Zone Bypass Change Appearance Alerts Help ALERTS Contact Name Email Address 5M5 Phone Test Edit Delete John Doe John Dosfiemail com 1234587820 ADD NEW System status received at 08 04 2008 18 01 40 localtime at
27. ds that include that detector shall not be available In this case press v to check which detector is causing the System Not Ready condition To make the required arming method available activate the detector If activating the detector does not help there may be a problem with the detector You can bypass the faulty detector s zone to allow system arming until the problem is remedied see Zone Bypassing Unbypassing 16 3 3 Disarming the System When you enter the premises the entry delay begins to count down You must disarm the system within the entry delay time to prevent the system from triggering an alarm To disarm the system using a keypad e Enter your user code To disarm the system using a keyfob e Press the disarm button see Keyfobs To disarm the System using a Smartkey if supported o Place a registered smartkey against the center of the smartkey reader of the Wireless Keypad When the smartkey is read the keypad will sound a beep the system is disarmed 3 4 Arm Status Indication and Other System Status Indication The system s arm status is displayed on the front panel only The following table explains the DISARMED various arm status descriptions that appear on 12 22 11 the LCD display Status Means DISARMED The system is disarmed FULL ARMED PART ARMED The system has been armed using the displayed arming method PERIMETER ARMED FULL ARMING PART ARMING dec n is
28. eceiver are displayed The fourth utility Environmental RSSI enables you to measure the RF noise level of the systems environment The Control System will start measuring the RSSI level every second and it will display the result on the LCD RSSI level can jump momentarily when a detector is activated It doesn t mean that the receiver is noisy To view the Environment RSSI level reading o From the Service menu select ENV RSSI 7044 the RF noise of the system s environment is displayed 44 Audio Volume To adjust the sensitivity of the microphone and the volume of the speaker 1 Establish a two way audio connection 2 From the Service menu select Audio Volume 705 9 Adjust the setting according to the following table Reading Meaning 1 Increase microphone sensitivity 4 Reduce microphone sensitivity 3 Increase speaker volume 6 Reduce speaker volume 4 Press V the new settings are stored in the memory GSM Signal Strength You can measure the GSM signal strength To view the GSM signal strength reading o From the Service menu select GSM Signal 706 the signal strength of the cellular network is displayed Reading Meaning 8 9 Reception is good 5 7 Reception is acceptable Less than 5 Reception is unacceptable Display Version To display the system s software and hardware versions o From the Service menu select Version 707 the software SW and HW versions are displayed Enable Progr
29. ectest bbectest bbectesi bbeciest oom feat ADD HEW System status received at 06 04 2008 17 14 50 local time at control system oa Lorg ii Taisen ST STEM PESKY TERRES STATIA Change Password Click Settings then Change Password to change the password you use to login to the Web Application ARHUDISARHM SETTINGS HISTORY VIDEO AUTOMATION LOG OFF System user and codes eb interface users and code s Change Password Ze ne Bypass Change Appearance Alerts Help CHANGE PASSWORD New Password Confirm Mew Pageword Old Password SET HESY FA SSYEIORD Please enter a new password Changing your passwora will mot affectyour user mam System status received at 06 04 2005 13 01 40 local time at control system EbonbestiLoeeel in Disarntenl e n AS 25 Zone Bypass On The Main Page menu click Settings then Zone Bypass to bypass certain zones in your home that you don t want to receive event messages from Select the checkboxes for the zones you want to bypass HOME ARM DISARM HISTORY WIDEO AUTOMATION Full arm A LOS OFF System users and codes Web interface users and codes Change Passweo u Zone Bypass CE ange Appearance Alerts Help ZONE BYPASS ame Siate Trouble 1 FRONT DOOR Ready Mo Bypass 2 BACK DOOR Ready Mo Bypaze 3 GARAGE DOOR Ready No Bypazz KITCHEN DOOR Ready Ho Cl bypass 5 SIDE DOOR Ready Ho O Bypass UPDATE Please click Up
30. edical Fire Gas Flood and Environmental are capable of generating an alarm A user code that generates a silent alarm to indicate that the user is being forced to operate the system E See Delay A browsable record of events that have occurred within the system See Delay 48 Follow me Forced Arming Front Panel Full Arming Global Chime HA Units Home Automation Instant Arm Keyfob LAN IP Address Limited Code Log Master Code Medical Emergency Message Center F A feature that enables users to receive notification to their telephone that an event has occurred in the system Arming before the system is ready If the system is not secured by the time that the exit delay expires an alarm is generated The main interface located on the front of the Control System consisting of an LCD keypad An arming method that activates the entire system when the premises are vacated G A feature that enables disables the Chime feature for the entire system see Chime H Home Automation Units abbr The lights and appliances in the home that are controlled by the optional Home Automation feature An optional feature that enables the user to control electrical appliances and lights via the Control System I An arming method that cancels the entry delay after the system has been Part or Perimeter armed K Handheld wireless transmitters used to remotely control the system L T
31. em trouble tones programmable option to repeat the are not sounded from tones every 3 hours until the 10 00pm to 7 00am problem has been taken care of 3 6 Remote Arming and Disarming Remote Arming Disarming via SMS You can arm and disarm the system remotely by sending the SMS commands from a cellular phone to the cellular communications module Each SMS command contains the following elements o SMS Command Descriptor up to 43 characters of free text e separates the descriptor from the actual command e User Code e Command 120 Disarm 121 Full Arm 122 Part Arm 123 Perimeter Arm 124 Full Perimeter Arm 125 Part Perimeter Arm 200 Arm Status The following example shows the format of an SMS command for disarming the system SMS Command Descriptor User Code Command D S A R M 1 2 3 4 1 2 0 While the SMS Command Descriptor is optional you must start the SMS command with the symbol for the system to accept the command Arm Status Reply On receiving an Arm Status request message the system returns a status message to the sender This message includes the system status and the descriptor of the user or the device used to arm disarm the system The following example shows an Arm Status reply where the system has been fully armed by a user named Mark FULL AR M E D M A R K SMS Confirmation Message After an SMS command is executed by the system if programmed by your installer a confirmation messa
32. en to pick up the relevant call For this purpose the Connect employs a double call method To make a call to the Control System using the double call method 1 Dial your telephone number 2 Wait for two or three rings then hang up 3 Wait at least five seconds and dial the number again on the second ring the Control System picks up and sounds two tones Making a Cellular Call to the System If your system supports cellular communication it has its own individual telephone number Therefore the double call method is not necessary and you may call the Control System directly 38 Call Procedure To prevent unauthorized attempts to call your Control System you must enter a user code when calling your home see User Codes Code 29 To call your home 1 Call the Control System either using the double call method or directly see above when the Control System picks up two tones are sounded 2 Enter the Telecontrol code Code 29 on your telephone within 15 seconds Do not enter your user code until you hear the two tones Any digits entered before the tones are sounded are disregarded by the system 5 A tone is sounded to indicate that the system is ready to receive commands The following commands are available e Press 2 for Two Way Audio If the TWA mode is defined as Simplex see Simplex Mode the audio channel opens in Listen mode microphone active speaker mute To switch to speak mode press 1 on your
33. equires an add on expansion module Home Automation enables you to control up to 16 individual lights and appliances around the home in this section we shall refer to these lights and appliances as HA units and PGM output The PGM is a programmable output that is triggered according to specific system status conditions or by remote command sent via PSTN GSM Ethernet keyfob keypad or Remote Programmer HA units and the PGM programmable output can be controlled using the keypad and keyfobs remotely by telephone or SMS or programmed to react to specific system status conditions For example an HA unit can be programmed to switch on when the system is armed or when a specific zone is triggered Additionally the Randomize feature is designed to switch lights on and off at night when the system is armed This gives potential intruders the impression that the house is occupied Scheduling options enable you to program On and Off times for each HA unit This feature is found in the main menu For further information on how to navigate the menu refer to Advanced System Operation 6 1 Keypad Control Two keys on the keypad enable you to send On and Off commands to HA units activate and deactivate the PGM output How HA PGM units react to the On command is determined by the installer in programming The HA PGM unit can be programmed to switch on until the Off command is received or automatically switch itself off after a pre programmed am
34. er as they appear in the menu The above procedure provides a detailed explanation of menu navigation However in order to simplity the procedures that appear in the rest of this chapter the following conventions are used This Means From the Bypass Zones Enter the main menu by pressing Vand entering your user menu select Unbypass code Using the arrow keys navigate until you reach Bypass All Zones and press v Using the arrow keys navigate until you reach Unbypass All and press v Select Use the arrow keys to scroll through the options and press v 61 The shortcut to a specific menu item from the main menu In this case this is the shortcut for View Log These appear in the procedures as an additional aid to menu navigation 36 8 1 Cancel Report The Cancel Report function enables you to prevent the system from reporting in the event of a false alarm To cancel report e From the main menu select Cancel Report 1 all pending messages to the monitoring service are canceled 8 2 Zone Bypassing Unbypassing When a zone is bypassed its detector is ignored by the system and does not generate an alarm when triggered To bypass or unbypass a zone 1 From the Bypass Zones menu select Bypass Unbyp 21 2 Using the arrow keys scroll to the zone you want to bypass or unbypass 9 Press Y to change the bypass status 4 Press X Save Changes is displayed a Press Y to confirm the changed bypass s
35. er indicating whether the P 2 2 1 14 08 12 34 Ra event was reported to the central station The options available are R Report Sent F Report Failed or N No s Report FIRE ALARM Se Default descriptor in this case the number of the zone The above example shows the event log entry for a Fire alarm in the Kitchen Zone 4 on November 14th 2008 The report was successfully reported to the central station 40 8 6 Service Menu The Service menu includes various functions that enable you to test your system effectively You can gain access to the Service menu using the Master code Set Time amp Date To set the time 1 From the Service menu select Set Time Date Set Time 7011 2 Enter the current time 3 Press V the time is modified To set the date 1 From the Service menu select Set Time Date Set Date 7012 2 Enter the current date 3 Press V the date is modified The format of the time and date is defined by your installer in programming If you are setting the time in 12hr format use the NE key to toggle between AM and PM Message Center The Message Center is designed to allow you to record a short message that may be played back later by another user After a message is recorded Message Waiting is displayed on the LCD until the message is played back To play back a recorded message o From the Service menu select Messages Play Message 7021 To record a message
36. ernet keyfob keypad or Remote Programmer R The state in which all zones are closed and the system is ready to be armed Control System s firmware update from a remote PC using WEB communication The restoral of a trouble condition to its normal state For example if AC power is reconnected an AC Loss Restore event code is sent to the central station Received Signal Strength Indication abbr RF noise of the system s receiver S A Home Automation feature that switches HA units on and off automatically according to pre set times The devices installed around the home that alert the panel in the event of an alarm A feature that enables the user to contact the monitoring service and talk to an operator via the Control System An SMS message sent to the Control System that causes the system to perform a specific function An RF ID device used to arm and disarm the system by placing it against the Wireless Keypad An SMS message sent to the user confirming that the SMS command has been performed Luminous indicators on the front panel that provide information on the arm and power status of the system 50 Telecontrol Tones Trouble Tones TWA TX TX List TX Test Unbypass User Code User TWA Code Walk Test Web Remote Programmer Wireless Keypad Zone Zone Bypassing T A feature that provides remote access via the telephone including remote arming disarming siren cancel and Two Way
37. ey Cancel Report Cellular Communication Chime Code Controlled Code Delay Descriptor Disarmed Duress Code Entry Delay Event Log Exit Delay A detector which is always active regardless of whether the system is armed or disarmed A The state during which the security system is activated In most cases when the system is armed triggering a detector generates an alarm The three keys on the front panel or keypad that activates one of the system s arming options A detector which is ignored by the system No alarm is generated from a bypassed zone even if triggered when the system is armed C A key on the Wireless Keypad that causes the system to disregard any partially entered code or command that may have mistakenly been entered An operation that clears all communication buffers and stops the transmission of any pending messages to the monitoring service Monitoring and control via a cellular network A feature that provides audible annunciation when specific detector s are activated See User Code A user code that causes the system to notify the monitoring service when used to arm or disarm D The exit entry delay times that allow the user to arm or disarm the system without generating an alarm Custom labels programmed for each user code zone keyfob keypad etc The state during which the security system is deactivated During disarm only detectors that are defined as 24hr Panic M
38. ge may be returned to your mobile phone The following example shows the confirmation message you receive for the sample command from the previous section DIS AR ME D AG Remote Arming Disarming via the Telephone Using the Telecontrol feature you can Full arm and disarm the system via the telephone For further information on the Telecontrol features see Telecontrol Remote Arming Disarming via WUAPP and WAP You can arm and disarm the system remotely using the WUAPP Web User Application and WAP see Web User Application 20 4 Web User Application The Web User Application provides a full interface to your system from a local or remote PC Via the Web you can perform a wide range of tasks such as arm disarm zone bypass user code management and home automation control You can also access the Web User Application from your cellular phone or PDA using the WAP portal 4 1 Logging In This application is usually part of the service provider s Web site and requires the end user to log in to gain access to the page To enter the Web Application on your browser enter the Web page address supplied by your WEB service provider and press Go You will see the Login Page Username 7 Password E Pass Code i Electronics Line 3000 Ltd provides innovative security f Use this web with remote management solutions to the residential and A application to commercial markets built upon 20 years of technological d pe
39. gering an alarm To initiate Walk Test mode 1 From the Service menu select Test and then Walk Test 7034 a list of registered detectors appears 2 Trigger each detector when the system receives a successful transmission from a detector the detector is removed from the list 9 When all the detectors are removed from the list End Walk Test is displayed 4 Press X to exit Walk Test mode Snapshot Test The Snapshot Test enables you to check if the video verification detector cameras are functioning correctly To initiate the Snapshot Test 1 From the Service menu select Test and then Snapshot Test 7035 a list of registered detectors appears 2 Select a detector from the list and press V a snapshot of the monitored area in taken and the results can be viewed in the Web User Application 9 Repeat the test for each installed detector 4 Press X to exit Snapshot Test mode 42 Transmitters The Transmitters menu offers a number of testing utilities TX List TX Test RF Link and ENV RSSI The TX List comprises all registered transmitters and their last reported status To view the TX list 1 From the Service menu select Transmitters TX List 7041 the first transmitter on the list is displayed 2 Using the arrow buttons scroll through the transmitter list 3 When you have finished viewing press X to exit the list The TX list displays the following information for each transmitter o FRONT
40. he address that your home router has assigned to the Control System A user code that automatically expires 24 hours after it is programmed See Event Log M The only user code with the ability to program other user codes The Master code also has exclusive access to specific system functions A type of alarm that informs the monitoring service that the user is in need of medical assistance An optional feature that enables users to record messages to be played back by other users 49 Non Controlled Code One Key Arming Panic Alarm Part Arming Perimeter Arming PGM Ready Remote Firmware Update Restore RSSI Scheduling Detectors Service Call SMS Command Smartkey SMS Confirmation System Status LEDs A user code that does not cause the system to notify the monitoring service when used to arm or disarm The system only reports if the code is used to disarm after an alarm O Arming the system without the need for a valid user code P A user initiated event that alerts the monitoring service in the event of an emergency An arming method that is designed to activate a certain section of the premises An arming method that is designed to activate the detectors protecting the doors and windows while enabling residents to move freely on the premises Programmable output that is triggered according to specific system status conditions or by remote command sent via PSTN GSM Eth
41. iconnect 2 e Way wwe See at da L Or eee Si WV 9 User Manual For quick installation information please refer to the iConnect gt Quick Start Installation Guide provided on our website www electronics line com EL UPGRADING EVERYDAY SECURITY Quick Reference Guide Function ARM INSTANT ARM DISARM PANIC FIRE ALARM ALARM MENU MODE CHECK TROUBLE CONDITIONS SWITCH HA PGM UNIT ON SWITCH then HA PGM UNIT HA PGM UNIT OFF SERVICE CALL GLOBAL CHIME RECORD MESSAGE Press FULL PART PERIMETER Hold down this key until Instant Arming OK is displayed Then Press v USER CODE MEDICAL then USER CODE Use this key scroll the system trouble list then HA PGM UNIT then then Additional Information If One Key Arming is disabled on the Control System enter your user code when arming The default Master code is 1234 Instant arming cancels the entry delay after Part or Perimeter arming This feature can be enabled by your installer Entering your user code also silences the siren in the event of an alarm Press these keys together and hold them down to generate an alarm Use the menu navigation keys a y until the required menu item is displayed then press v Alternatively enter the shortcut e g 21 for Bypass Zones Pressing also silences any trouble tones that may be sounded
42. iew in the event log events that can be viewed only by the installer are not sent to the Follow Me number see Two Way Audio Follow Me If using the TWA Follow Me feature the audio channel is opened after alarm events only To edit the Follow me number 1 From the main menu select Telephone 5 2 Enter a telephone number for Follow Me communication If using the SMS Follow Me feature this number must be for a cellular phone with the capability to receive SMS messages You may only access Follow me programming if the protocol for Account 3 is programmed as SMS or TWA Follow me 8 5 Event Log The event log records events that have occurred within your security system When the log is full the oldest events are automatically erased and are replaced by new events To view the event log 1 From the Event Log menu select View Log 61 the most recent event is displayed 2 Press the left SOS button We to display the Time Date stamp or the default descriptor on the second row of the display 3 Use the arrow keys to scroll through the events 4 When you have finished viewing press X to exit the log The event log displays the following information for each event O The event a brief description of the event that occurred OFIRE ALARM O Zone descriptor exactly where the event occurred por aX ITCHEN Time date stamp the exact time the event occurred p FIRE ALARM Report details a single charact
43. in the process of arming displayed during exit PERIMETER ARMING AAA LL The system has been armed using the displayed arming method PERIM ARMED INST with the Instant arm feature activated PART ARMING INST The system is in the process of arming with the Instant arm PERI ARMING INST feature activated The system may be programmed to display arm status at all times or only for the first two minutes or 30 seconds after you arm or disarm the system according to the system s configuration as programmed by the installer 17 In addition to arm status the system displays further status messages on the front panel s display The following table explains common status indication messages that may prevent you from arming your system Status Means ZONES IN ALARM Zones have been violated TAMPER ALARM The system has been tampered with SYSTEM NOT READY The system is not ready to arm check that all doors and windows are closed KEYPAD LOCKED Five unsuccessful attempts were made to enter a user code the keypad is locked for 30 minutes If this message appears it is still possible to arm disarm the system using a keyfob Arming is possible using a keypad if one key arming is enabled SYSTEM TROUBLE A trouble condition has been detected press for further details de System tones are the chimes that the system sounds to indicate entry exit delay arming and disarming system troubles and so on Various options are availa
44. in your home To generate a panic alarm press both Home Automation keys simultaneously and hold them down Cancel The Cancel key clears the keypad in the event that you pressed a key by mistake For example when entering your code you enter a wrong digit the system waits for you to enter all four digits before it decides that the code is incorrect Pressing the Cancel key causes the keypad to disregard what was previously entered enabling you to start again 13 LEDs Two status LEDs OK and 0 indicate arming and power status of the system If the OK LED is It means Off The system is disconnected from all power sources On Green The keypad is powered by AC and the battery is not low Flashing Yellow slow Local backup battery low Flashing Yellow fast Wireless Keypad AC loss 8 It means If the LED is Off The system is disarmed On Green The system is armed Flashing Red An alarm has occurred This alarm indication is reset when the system is armed using any of the three arming methods LS Alarm indication is not displayed after a silent panic alarm 14 3 Arming and Disarming Arming can be defined as activating the system When the system is armed it monitors the zones that are protected by the detectors If a detector detects an intrusion the system generates an alarm 3 1 Arming Modes Three arming modes are available Full Part and Perimeter These modes enable you to arm your
45. l to the Control System indicating that it has sensed motion on the premises On receiving this signal the Control System makes the decision to report the alarm to your monitoring service and activate the siren Detectors Detectors are the devices that protect your home alerting the Control System when there is a breach in security Magnetic contacts protect your doors and windows while motion detectors with built in video modules are able to detect an intruder moving across its field of view and snap an image as proof of intrusion Additionally smoke carbon monoxide gas leak and flood detectors can be installed to provide an early warning in the event of a fire the presence of dangerous gases or the potential for flooding Keyfobs Keyfobs are hand held transmitters that are used to operate the system Various keyfobs are available providing a number of functions For example arming disarming the system sending medical and panic alarms and various home automation functions Keypads The keypads enable you to communicate with the Control System in order to perform a number of different functions The main function you can perform using a keypad is to arm the system when leaving your home and to disarm on your return Sirens and Strobes While the Control System includes a built in internal siren it is possible that you also have an external siren and strobes installed The sirens are sounded and the strobes are activated
46. ly members via a Web control over your home installed in your home personal location based service appliances Control automated devices and schedule daily activation Welcome to a comprehensive interface to your home The current status of your system is displayed in the status bar at the bottom of this page U an arm or disarm your system or select any of the functions listed above Status Bar System status received at 14 09 2009 09 09 26 local time at control system Carrier gt 10 42 When using the Smartphone application service the main page Disarmed Read looks the following way isarmed Ready A e Disarm Arm Partial Arm i gt q Last Alarm Images g Detectors Alerts a E T o Home Menu Bar The Menu Bar includes the Main Menu arm disarm options list and the Log Off button The Main Menu offers links to various pages in the Web Application Use the Logoff button on the right side menu to properly close the session The following options are available from the Main Menu Home pressing the Home button allows the user to return to the Main page at any time o Settings offers various options including user code and contact management event log viewing and zone bypass e History enables you to view the system s event log e Video provides access to view streaming video from IP cameras 22 e Automation all
47. nterface lo your home The current shale of your system de displayed ir Ine stalus bar at the bottom of this pags Using this application you can anm or disarm your system or select any of the functions listed above System statis receives at 06 04 2338 17713758 local time at control system In this area you can add delete or change users and the User Codes for your system for example add codes for family members 1 On The Main Page menu click Settings bbectest Logged in 2 Click System Users and Codes the following page appears HOHE SETTINGS HISTORY VIDEO AUTOMATION Fuam FET System users and codes Web interface users and codes Change Password Zone Bypass Change Appearance Alerts Help ARRMIBISARTA Login Hame Full Warme Ermail Edit Belete 1 bbscisei bbeciset bhoctesiibbecisst com Eat O ADD WHEW System status received at 06 04 2009 17 14 59 local time at control system REFRE SH Tema boots Lagnel T Diss SHS TEM READY 24 Web Interface Users and Codes The Web Interface Users and Codes page provides a useful tool for managing your system s users From this page you can add edit and delete users as required You can even issue temporary limited codes to guests that will expire after 24 hours On The Main Page menu click Settings then Web Interface Users and Codes the following page appears Login Name Full Barre Emaii Edit Delete 1 bb
48. onnect supports two types of keyfob transmitter EL 4714 EL 4711M P The functions of the buttons on each keyfob are shown below Full Arm Disarm Oy Medical Panic Perimeter Arm Part Arm Emergency or Home or Home Automation PGM Automation PGM EL 4714 EL 4711M P 2 4 Wireless Keypads The system supports up to four Wireless Keypads The Wireless Keypad EL 4727 is an intelligent two way wireless keypad with LCD display Apart from serving as an additional arming station the Wireless Keypad provides memo recording options control over up to 16 home automation devices and panic alarm function You can arm and disarm the system using the Smartkey if supported 12 1 Speaker 2 LCD Display 3 Arming Keys 4 Keypad 5 Microphone optional 6 System Status LEDs 0000000000 EL 4727 Numeric Keypad The numeric keypad allows you to arm or disarm the system by entering a user code Arming Keys Three arming keys Full Part and Perimeter allow you to arm the system using one of the three arming methods see Arming and Disarming One key Arming is an option that is programmed by your installer If this option is disabled you must also enter a user code when arming Panic Alarm Simultaneously pressing the Full and Perimeter buttons generates a panic alarm PGM Home Automation On Off Keys Pressing one of the Home Automation keys followed by the unit number 01 16 enables you to control lights and appliances
49. ount of time To turn HA PGM units on 1 Press the On key 2 Enter the two digit HA PGM unit number 01 16 or 30 31 for PGM the chosen HA PGM unit switches on ing the keypad To turn HA PGM units on using the keypad 1 Press the Off keyW8 2 Enter the two digit HA PGM unit number 01 16 or 30 31 for PGM the chosen HA PGM unit switches off 6 2 Keyfob Control You can control two separate HA units using the four button keyfob This option can be programmed by the installer For further information on keyfob button assignments refer to Keyfobs 30 6 3 Telephone Control Using the Telecontrol feature you can control HA units and PGM output remotely via the telephone For further information on the Telecontrol features see Telecontrol 6 4 SMS Control If your system supports cellular communication you can control HA units and PGM remotely via your mobile phone using a number of SMS commands The SMS commands are designed to be entered as templates on your mobile phone Each SMS command contains the following elements e SMS Command Descriptor up to 43 characters long o separates the descriptor from the actual command d User Code e Command 0 Off 1 On o HA Unit Number 01 16 or 30 31 for PGM The following example shows the format of an SMS command to switch on a water boiler controlled by HA unit 08 SMS Command Descriptor User Code On Unit B O I L E R O N 1 2 3 4 1 0 8
50. ows you to control and schedule automated lights and appliances in your home o Help offers online explanations on how to use the Web Application plus FAQ and customer support options Status Bar The Status bar displays information on your system s status and the name of the user currently logged in Above the status bar the time when the system status display was last updated is shown This information is displayed according to the local time at the control system When logging into the WUApp with a GPRS Control System the system status refreshes automatically and can be refreshed manually as well To refresh the current system status click the Refresh Status button on the right hand side of the Status bar Workspace The workspace offers additional links to the following pages of the application Users and Codes History Alerts Change Password Video When you choose a page either from the Main Menu or from the workspace the page is displayed in the workspace For example if you choose Arm Disarm from the Main Menu System Operation area and System Status area are displayed in the workspace see the figure below Home Button On the main menu there is Home button Press the Home button to return to the Main page at any time 4 3 Arming and Disarming via the Web Application ome anmmisanm sermmos msrone veo auromanon J CS E r Perimeter Arm Part Arm Part Perimeter Arm Full Perimeter Arm
51. r Codes As an additional security measure make certain that you delete any extra codes that are no longer required To delete a user code 1 From the main menu select User Codes 4 2 Select the code you want to delete 9 From the code s sub menu select Edit Code the 4 digit code is displayed with the cursor flashing on the first digit 4 Enter 0000 5 Press V the code is deleted E The Master code cannot be deleted User Code Descriptors Using the alphanumeric keypad on the front panel you can edit the 16 character user code descriptors and enter the name or title of the users to whom the code is allocated To enter text press a key repeatedly to scroll through the characters that appear on the key For example press 6MNO to enter M N O or 6 respectively You can also use the 1 and 0 keys to enter symbols After you enter text the cursor automatically moves to the before the current character Use the Right SOS button y character To edit a user code descriptor 1 From the main menu select User Codes 4 2 Select a code 3 From the code s sub menu select Descriptor 4 Edit the descriptor using the alphanumeric keypad 5 Press Y when you have finished editing 39 8 4 Follow Me The Follow Me feature is designed to notify the user that certain events have occurred The events that are sent to the Follow Me telephone number are those events that the user is authorized to v
52. rform a wide leadership Multiple technologies and applications are range of tasks such integrated to enable real time data audio and video o AS as arm disarm zone solutions which are communicated via PSTN GSM GPRS bypass user code and TCP IP connections management and 1 e home automation A control l Control and schedule automated To login to the Web Application enter your user name and password supplied by your WEB service provider and the pass code which is your User Code then click the Enter button A N For your system security reasons you must change the password immediately at first login You can change your password on the Change Password page that is accessible from the Settings menu Your new password should be no less than six characters and must start with a letter 91 4 2 The Main Page After logging in your system s home page is displayed The following diagram shows the home page and explains the main elements of the web application s interface ARM DISARM SETTINGS HISTORY voeo LOCATOR AUTOM TION LOG OFF Menu Bar Settings History Arm and disarm your control system Manage different aspects of your View a full list of system events that remotely control system and web user occurred in your home Print or save inter the log file wy ArmiDisarm Workspace lm f Au Video Locator ag Automation View streaming video via IP cameras Locate fami
53. tatus To unbypass all zones 1 From the Bypass Zones menu select Unbypass All 22 2 Press V all zones are unbypassed All bypassed zones will be automatically unbypassed when the system is disarmed A fire zone cannot be bypassed 8 3 User Codes The iConnect 2 supports a variety of individual user codes Each of these codes is four digits long Most system functions require you to enter a valid user code The ability to perform a function is defined by your user code s authorization level These authorization levels are pre defined for each code as explained below Code 1 Master Code The Master code is the highest user authorization level With the Master code you can edit all other user codes Additionally the Master code grants access to the Event Log the Service menu and Home Automation Schedule programming The default Master code is 1234 Change this code immediately after the system has been installed Codes 2 19 Controlled Codes When you use a controlled user code for arming and disarming the system notifies the monitoring service 37 Codes 20 25 Non controlled Codes Non controlled codes do not cause the system to send Arm Disarm reports to the monitoring service The system sends a Disarm report only if you use this code to disarm the system after an alarm occurrence Codes 26 27 Limited Codes A Limited code enables you to issue a code that is valid for one day only This code automatically e
54. telephone To switch back to Listen mode press 0 on your telephone During the TWA session you can adjust the speaker volume ce using the arrow buttons e Press 3 to fully arm the system e Press 4XX to turn HA unit XX ON e Press 430 to activate PGM output Unit 30 31 e Press 5XX to turn HA unit XX OFF e Press 530 to deactivate PGM output Unit 30 31 e Press 6 to disarm the system e Press 9 to cancel the siren The commands 3 Full Arm 4 HA PGM On 5 HA PGM Off E 6 Disarm and 9 Bell Cancel can also be executed at any time during a Two Way Audio session Error beeps three tones are sounded in case of a wrong command To clear the last command press or 4 4 The duration of the call is an option programmed by your installer Ten seconds before the end of the call two short tones are sounded To extend the call press 7 on your telephone 5 To disconnect before the end of the call press then on your telephone Siren Muting The siren is muted during Two Way Audio communication At the end of the call the siren is re activated if the Siren Cut Off has not yet expired You can cancel the re activation of the siren by pressing 9 on your telephone during the call 34 d ds Service Call The Service Call feature enables you to call the monitoring service by pressing one Key To make a Service Call 0
55. the premises you are informed no matter where you are in the world 1 6 Telecontrol The iConnect offers a range of Telecontrol features that provide remote access via the telephone These features include remote arming disarming HA on off PGM output activation deactivation siren cancel and Two Way audio via the Control System s built in microphone and speaker see Telecontrol The Two Way Audio features allow you to contact your home directly in the event of an alarm or simply to check the premises when you are away Using your cellular phone you can also send commands to the appliances controlled by the Home Automation feature using SMS and receive confirmation when the command is received 8 1 7 Vocal Message Annunciation Vocal message annunciation is an optional feature that if enabled in programming causes the system to play short messages that indicate system status 1 8 Web Access The Web Application provides an interface to your security system from your Internet browser Via the Web you can perform a wide range of tasks such as arm disarm zone bypass user code management and home automation control Additionally you can set up the contacts whom you wish to be alerted by email or text message when selected events occur The application also allows you to check your home at any time either by viewing a history of recent events that have occurred or by viewing streaming video from cameras inst
56. ver the Web in order to check your home and family while you are away Discuss this capability with your security service provider to determine if it is applicable to your system 28 5 Panic Alarms Panic alarms enable you to send a message to the monitoring service in the event of an emergency There are various types of panic alarm and several methods you can use to generate them 5 1 Keypad Alarms To activate an SOS Panic alarm from the front panel or wireless LDC keypad py F n C38 o Press and hold down the Home Ko NI f 9 E ora EC 3 i Vi NETA pate Automation On and Off keys Joe mer a d Ya N y simultaneously H To activate a Fire alarm from the front panel keypad or wireless LCD keypad pee hy URN qme a S d s g7 3x f e Press and hold down keys 1 and 61 3f 8B Y Jai PAIN BO NOR NN 3 simultaneously gc pes S5 S A pS Pi A y PEN ENS e Press and hold down keys 4 and 4569 376 6 simultaneously iG a N 5 2 Keyfob Panic Alarm To activate a Panic alarm using the four button keyfob EL 4717 e Press the lower two buttons simultaneously 5 3 Medical Panic Alarm The one button keyfob EL 4711M P is designed to send a message to your monitoring service in the event of a medical or panic emergency The transmitter is water resistant and can be worn around the LN neck as a pendant Y D 29 6 Home Automation and PGM Home Automation is an optional feature that r
57. xpires 24 hours after it has been programmed Code 28 Duress Code The Duress code is designed for situations where you are being forced to operate the system This user code grants access to the selected operation while sending a Duress event message to the monitoring service Code 29 Telecontrol Code The Telecontrol code is designed to enable the user to perform a number of tasks via their telephone using DTMF commands Using this code the user can call their system to arm and disarm turn on and off HA units activate and deactivate the PGM output cancel the siren or establish Two Way Audio communication This code can only be used for this specific purpose and does not grant access to any additional system functions such as disarming Editing User Codes User code editing is a feature that is available exclusively to the Master code To maintain a high level of security keep all user codes confidential To edit a user code 1 From the main menu select User Codes 4 2 Select the code you want to edit 3 From the code s sub menu select Edit Code the 4 digit code is displayed with the cursor flashing on the first digit 4 Edit the code 5 Press V the new code is stored in the memory If you enter a code that is identical to an existing user code the Control System sounds an error tone and the new code is not accepted 0000 is not a valid user code as this value is used to delete a user code 38 Deleting Use