Home
USER MANUAL
Contents
1. wa hy Then select SEt 2 option and enter upper threshold value Ke gt lt Choosing Ser option will cause ae hy starting work with signalisation of 100 MENU exceeding thresholds and zero gt hy To change Relays socket mode use thr t A 0 7 option Default option is Jndication wW OK hy To leave the function press MENU key and then choose thr and thr 0 options 33 USER MANUAL 14 15 Total weight function totAL The function allows calculating total weight for series of measurements which can be grater than scale capacity It allows calculating total weight as well as average value E 0 00 MEND Press MENU key v hy When otAL is displayed press gt 7 lt key totAL sae The following options appear successively Ka hy tot P report printout without clearing tot 1 total register Ae SE 77 ott clearing total register report SE w hy printout and leaving the function tot 1 working with receipt printout 10 00 IG after each measurement hy tot 2 working without receipt v printout 0 00 Press gt T lt key when tot 1 is displayed Perform measurement series pressing L gt WwW key for storing results into total register 20 00 IG In order to print and display results enter v hn to function choos
2. 37 USER MANUAL 14 18 Setting time of stabilization function Stb The function allows changing stabilisation time of scale indication and connected with it the time of waiting for starting result printout on a printer connected to the scale Press MENU key 0 00 MENU When Stb is displayed press gt T lt key Vv h The following options appear successively on display GD gt E Stb 0 deactivate the function v h Stb 1 the longest stabilisation time Stb 2 long stabilisation time Sb 5 FF Stb 3 medium stabilisation time Stb 4 shorter stabilisation time VW hy Stb 5 the shortest stabilisation time E 0 00 After choosing one of the options weighing with activated filter is started In order to go back to normal work of the scale choose Stb 0 option 38 USER MANUAL 14 19 Entering reference zero function Zero Note This function is enabled in non legalized scales only ZER function allows entering new value of reference zero value referred to empty pan without need of contacting with authorised service centre Err b MENU v D ZEO D e D ZE 1 gt e D Eod F0 v bb
3. s ss ssssssssssssunsusnnnnnnnnnnnnnnunnnnunnunnnnnnnunnnnnas 25 14 9 Percentage weighing function PErC sssssssssssssnsusnnnnnnunnnnnnnnnnnnunnunnunnnnunnnnnas 26 14 10 Anti disturbance filter function FILtEr ss sssssssssssssnsrnsnsnnnnnsnnnnnunnnnnnnunsnnnas 27 14 11 Function for maximum value indication UP cssssssssssssssssessscsersssnsesssees 28 14 12 Force measuring function nEWto ssssssssssssssssnsusnnnnnnnnunnnnnunnnnunnunnunnanunnnnnas 29 14 13 Function for weighing large animals LOC cccssssssssssssssssssssscsssstsssssees 30 14 14 Checkweighing function thr s sssssssssssssnsnnsunnunnnnunnunnnnunnunnnnnnnunnnnnnnunnunnnnunnnnnas 31 14 15 Total weight function totAL s ss ssssssssssnsnnsunnunnnnunnunnnnunnunnnnnnnunnnnnnnunnunnnnunnnnnas 34 USER MANUAL 14 16 Function for setting date and time GATE sssssssssssssescscscrsssssesssssesesesseees 36 14 17 Function for selecting label number LADEL 1 ssssssscsssssssssssssseseseessees 37 14 18 Setting time of stabilization function Stb ssssssssssssssssescscrsssnsssssssesesesseees 38 14 19 Entering reference Zero function ZELO cccsssssssssssssssssscnsrsrsnsesssnseeneseees 39 14 20 Automatic switching off the scale function AUtOOF see 40 14 21 Density determining function AENSIt cccssssssssssssssssescssrsssssssssssesesesseses 41 14 22 Calculator for good packaging control tP
4. ssssssssssssssescscsssssssssseseseseeseees 43 14 23 Statistical calculations function SAL ccscssssssssessseseecsssssnsesssnseaeeeeees 46 14 24 Paperweight calculation PAP ss ssssssssssescscsssssssssssssssecssessssssssssseseseseees 48 15 Maintenance and Small repair scccccssssssssssssscssescsssnssessssnensesessssssensnsesaseseaseneneaes 49 Deciaration of CONIOMMILY iii ecco tien dion dunia nena ea a 50 USER MANUAL 1 Basic description B60P platform scales are designed for general use Thanks to built in accumulator and a case to transport the scale on demand B60P is a great portable balance All scales are metrological tested calibration or legal verification on demand Scales have following verification features a seal protecting scale casing against opening notified body stamps and green metrological marking placed on the balance name plate Renewing of scale legal verification is required when protective seal is violated or after period of 3 years starting from 1 December of year when first legal verification was performed In order to renew legal verification please contact authorized service of AXIS NACE classification 29 24 23 Certificates f TS am Car EC Type Axis management System Approval certificate Certificate DIN EN ISO 9001 2000 No PL 04 022 No 78 100 6386 2 Completation Basic set includes 1 Scale 2 4 legs 3 Feeder 4 User manual 5 Guarantee
5. USER MANUAL B60P File 2010 10 BP 131 B 50_0 GB USER MANUAL Table of contents 1 BASIC COSCHDUON EE 4 2 gt Completati E 4 Be echnical data iier a aaa E A Ea ae Aai n N ai 5 4 K ys E 6 5 Security Prneiple eegener 7 6 Environment protection EE 7 T Prepatation e EE 8 le ET EE 8 9 G n ral Tulos tere ege 9 10 Balance checking EE 10 11 Scaleadjustm nt ioe aid chain iia aaaea arabes neha ks 10 12 Connecting to a computer or a printer Optional ssssssssssssssssssscsrsssssssssees 10 13 Tel EE 14 13 1 Normal WEIGHTING E 14 13 2 Weighing with tare s sesssssssssnsnsnnnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnanannnnannna 15 13 3 Increased EE 15 14 Special functions describtion ss ssssssssssssnssnnsnsnnunnunnnnnnnnnnnnnnnunnnnnnnunnunnnnnnnnnnas 16 14 1 Menu customization function ACtIV and AEFAUL sssssssssssssccscssssssssssees 17 14 2 Autozeroing function AULOZE sssssssssssssssesesssssssssssecsssesesessessssseecasacasrsnsnsnsees 18 14 3 Pieces counting BE sires eegene Seege Sieger 19 14 4 Printer cooperation settings PYINt ssssssssssssssscsesesessssesssssssssssssstsesssees 20 14 5 Serial port parameters Setting POFt sssssssssssssscscssesesessssssssessscsersrsesnsesess 21 14 6 Constant Tee 22 14 7 Average calculation function AVErAG s s ssssssssssussnsrnsnnnnsnnnunnnnnnnunnnnnannnnnnnas 24 14 8 Recipe weighing function RECIPE
6. 1 EF v P 12 G0 0 vy hb 12 PF soo P 1234 IMENU v D 5007 b0 b 0 00 Press MENU key When Zero is displayed press gt T key The following options appear successively on display ZEr 0 activate function ZEr 1 enter new zero value ZEr 2 enter new protecting code Using gt T key choose ZEr 1 and enter access code for function in new scale it is 1234 Direct result from A C converter will appear on scale display When the pan is empty press gt 0 lt key Wait for finishing zeroing process In order to change access code use ZEr 2 option Entering value is performed similarly as with ZEr option 39 USER MANUAL 14 20 Automatic switching off the scale function AutoOF The function is helpful in scales supplied from accumulator The function causes scale to switch off automatically after c a 10 minutes of not using it Switching function on causes last entered zero and tare values are remembered in scale memory After next start up of the scale these values are restored Press MENU key When AutoOF is displayed press T lt 0 00 MENU key wW hy The following options appear successively on display Auto OF jF Auto 0 activate function Auto 1 deactivate function v After function activation scale will Auto 1 FF control changes of its indications If the scale will not be used and scale V hy i
7. gt T and MENU tAr 4 printout a setting value of tare If the function is NET indicator is displayed active Options tdr enables to activate the function with previous tare value after leaving the function with tAr 0 option Note Tare value is stored in memory also after unplugging the scale from the mains USER MANUAL Weighing with constant tare j KS Ca 1 70 Lo o NET 10 00 WG b BG 11 70 23 When tAr function is activated press 0 lt key to zero the indication and to recall tare value from the memory Tare value is displayed with sign B G key enables for instant switching between net and gross weight Note When the pan is empty 7 lt key does not operate to tare the scale use 0 lt key USER MANUAL 14 7 Average calculation function AVErAG The function allows for calculating average value of performed measurement series During series of measurements successive results are registered automatically when scale indication is stabilised lt 0 00 MENU h AUEYAG gt T v b AUW 1 gt T v 1 00 CC ea Press MENU key and select AUErAG pressing T lt key The following will be shown successively on
8. 6 Case to transport the scale option on demand USER MANUAL 3 Technical data Accuracy dass O S Internal supply Lead acid battery 6V 12Ah Accumulator working time about 10 hours Ooo F OE EC verification Be USER MANUAL 4 Keys and indicators key VO switch on switch off standby key gt T lt tare subtract package weight from weighed mass key B G gross weigh indication switch key Ale zero key MENU special functions menu key Ss print out key HR increased indication resolution indicator gt 0 lt zero indicator indicator ae result stabilisation indicator indicator NET net weight indicator indication with subtracted tare indicator MODE special function setting bar indicator total load indicator graduated 0 100 indicator OFF _ standby indicator B G _ gross mass key B G indicator pcs pieces counting Max Min d e II metrological parameters and accuracy class Attention gt 0 lt B G HR keys and gt 0 lt B G NET indicators don t work in scales without legalization with graduation dee USER MANUAL 5 Security principles To avoid electrical shock or damage of the scale or connected peripheral devices it is necessary to follow the security rules below e All repairs and necessary regulations can be made by authorised personnel only e To avoid fire risk use a feeder of an appropriate type supplied wit
9. 93 68 EEC council directive Additional information Conformity evaluation for the Council Directive 73 23 EWG and 89 336 EWG were carried out by Laboratorium Badawcze Oddzia u Instytutu Elektrotechniki w Gda sku accredited to PCA Approval certificate no PL 04 020 issued by Central Office Of Measures in Warsaw Notified Unit No 1440 Gda sk 9th of January 2008 Authorized by the Director AXIS Sp z 0 0 Production manager mgr in Jan Ko czak ignature 50 USER MANUAL NOTES 51
10. When LOC function is displayed press v hn gt T key The following options appear on display successively LOC ed 2 LOC 0 leave the function ky hy LOC I automatic weighing after loading the scale LOC 0 LOC 2 the measurement initiated manually by pressing L gt key When LOC F is displayed press LOC 1 k gt T lt key v hy Tare the scale using gt T key if necessary and place the animal on the Z pan 0 25 7 TN Wait until the weighing result is v averaged scale display will be blinking Then scale will show stable Print averaged result and will send it through w serial port Final result is displayed on the display and send via serial port to 0 25 computer or printer The result remains on display for about 30 second Important notes 1 The loads less than Min are not averaged 2 In the case when placing the animal takes more than 5s it is advised to use LOC 2 option measurement initiated manually It will allow performing measurement in right moment pressing K key 30 USER MANUAL 14 14 Checkweighing function thr This function allows comparing weighing result with two programmed reference values lower and upper threshold Comparison result is signalled with indicators MIN OK MAX and sound signal generated when threshold values are exceeded If comparison resul
11. computer with L gt key USER MANUAL 14 Special functions describtion List of available functions menu customization function ACZIV removal of all function from menu dEFAUL autozeroing function AutoZE pieces counting function PCS function for setting serial port working Print function for setting serial port Port entering tare function t4rE recipe weighing function rECIPE weighing large animals function LOC force measuring function nEWto maximum value indication function UP anti disturbance filter function FILtEr average calculating function AVErA percentage weighing function PErC extended calibration function CALIb setting time of stabilisation function Stb selecting label number function LabEL automatic switching off scale function AutoOF entering reference zero Zero determining solids and liquids density function dEnSIt calculator for good packaging control tP option statistical calculations StAt option paperweight calculation function PAP option UU DUDU DUDU DUDU UU function with additional equipment require options with the clock setting current date and time function dAtE total weight function totAL options with the transoptors connectors checkweighing function thr Functions offered with special version of scale software with limited possibility of using other special functions User create own menu by choosing func
12. display AUEr 0 leaving function AUEr I measurement with average calculation Select AUEr 1 It will allow weighing with simultaneous storing results into summing register for average calculation Measurement registration is performed automatically in the moment when scale indication becomes stable Short time displaying of denotes that load can be taken off and new one can be put on Results above scale Min are registered only Number of measurements is limited to 9999 In order to read average value LF key should be used first pressing causes displaying number of measurements n second displaying causes displaying average value third pressing allows continuing average calculation If a printer is connected to scale the following report will be printed Date Time MEASUREMENS No AVERAGE VALUE In order to finish calculation press MENU key and then select AUEr i AUEr 0 24 USER MANUAL 14 8 Recipe weighing function RECIPE 0 00 MENU v rECIPE gt T v rECI 0 S rECL 1 k we _0 11 gt T 0 00 v 0 12 gt T se 0 00 v 0 13 MENU v gt rECIPE gt T rECL OI gt T v 0 36
13. enter dEnS t function menu and use 2 0000 dEn P option First pressing E key causes displaying successive v measurement number Second 0 00 pressing L gt key causes displaying and printing result and then going to the next density measurement 41 USER MANUAL If a printer is connected to the scale printout of solid density measurement results will be performed in the following form Date MEASUREMENT No WEIGHT in air WEIGHT in liquid HANGER WEIGHT LOAD DENSITY LIQUID DENSITY It is recommended to use pan hanging below balance weighing in the air and in liquid is performed then in the following way Phase I measurement in the air BAG Phase II measurement in liquid 42 USER MANUAL 14 22 Calculator for good packaging control tP Note This function is enable for special orders substitutable with other functions The function allows performing not destroying control of 60 100 or 160 samples of packed goods Calculation formula complies with the description of reference method described in act of law from 26 07 2001 with later changes Scale operator enters nominal net mass Qn and sample quantity taken for control quantity refers to total quantity of samples 1 and 2 in description of reference method Accepting successive measured packages storing in register is performed automatically after load is put on and scale indication is sta
14. of four filters This will cause starting weighing with selected filter In order to go back to normal weighing use MENU key once more and choose FILtEr and FIL 0 USER MANUAL 14 11 Function for maximum value indication UP This function allows holding on display maximum value shown by the scale in a while lt 0 00 MENU Before measurement scale should be v hy tared After using MENU key and selecting uP a UP function the highest mass result WwW hy will be hold on display Pressing gt T lt key will cause result LP O zeroing We Note Autozeroing function and the UP 1 adba stabilisation indicator are hy deactivated when UP function is v running Weighing result is 1 00 continuously averaged from 5 109 1g measurements v 10 00 v 10 00 28 USER MANUAL 14 12 Force measuring function nEWto 0 0 MENU v D nEMo PF v b nEW 0 ay nEW 1 F v gt 0 000 29 Function activation causes displaying result in force units N Press MENU key Using T lt key choose NEWto function and then NEW 1 Note 1Nx0 1019kg USER MANUAL 14 13 Function for weighing large animals LOC The function allows weighing animal moving on the scale oe Press MENU key KZ 0 00 MENU
15. 25 This function allows for separate weighing of several ingredients in one container with a possibility of control total weight of all weighed components The function has the following options rECI 0 leave the function with possibility of reading to read total weight rECI 1 start recipe weighing rECI 2 continue previous recipe When preparing a recipe successive ingredients A B C etc are weighed each time starting from zero indication In order to allow this after weighing of each ingredient tare the scale After weighing of several ingredients reading total weight is possible despite scale taring In order to do that press MENU key select rECIPE function once more and use rECT A option Sign e signals total weight indication Recipe is finished when gt T key is pressed When sign is displayed recipe continuing is possible rECI 2 option is used for that Note Sign on the left side of display informs about rEC PE function activity USER MANUAL 14 9 Percentage weighing function PErC This function allows displaying weighing result in percents A measurement is performed in two 0 00 phases first phase weighing a reference v sample 100 second phase measuring specific 1 70 IMENU sample as a percentage of hy the reference sample v W
16. RON data transmission protocol This protocol allows printing scale indication and optionally date and time on label printer as variable texts Other data e g company address product name its bar code can appear on label as constant fields Label forms used by user named as a numeric value max 4 digits should be previously stored in printer memory according to printer user manual Choosing label form is performed by entering label number using LAbEL function Press MENU key 9 00 MENU When LAbEL is displayed press v hy gt T key The following options appear LAbEL Ce successively on display LAb 0 leave without changes K hy LAb 1 enter label number Using T lt key select LAD 1 LAb 1 gt F lt hy For entering label number the following keys should be used Td L gt 0 lt increase digit Ei gt T move to next digit v hy MENU finish entering 2 PF After putting load on and pressing gt key data is sent to a printer gt v b S i 2 gt le gt le e 0 See Format of data sent to label printer v h US 55 53 0D 0A 27 MENU FR 0001 46522230 30303122 0D 0A 3F 0D 0A w hn 00 00 30 303A 30 300D 0A 2000 00 00 32303030 2E30302E 3030 0D 0A 10 g 20 202020 20313020 20670D 0A 5 00 e Pl 50 31 0D 0A
17. SL allowable lower value USL allowable upper value A B C measurement intervals na amount of measurements in A interval measurement is in A interval if it is bigger or equal to A interval threshold and smaller than B interval threshold Ng amount of measurements in B interval measurement is in B interval if it is bigger or equal to B interval threshold and smaller than C interval threshold Thresholds are printed under histogram NG amount of measurements under allowable lower value NG amount of measurements above allowable upper value To finish work with this function and zeroing result register press F key then during F StA and F 0 is displayed press Ale key This will cause printing message about register zeroing Data SAMPLES TOTAL MASS AVER MASS MIN MASS MAX MASS MAX MIN S SREL HISTOGRAM LSL geg USL DIV A B C D E F G H I J U EZE ZE Ll l l ramma Ww gt l Measurement made by Cooperation between statistics function with computer and printer The scale can be equipped with two RS232C connections marked as RS232C I computer and RS232C II printer After each printer data printout identical set of data is send to computer After S A CR LF 53h 49h 0Dh OAh initialization signal is sent by computer the scale sends to computer statistical data contained in histogram 47 USER MANUAL 14 24 Paperweight calcul
18. T lt key To leave the function press MENU key then with Ale key chose AutoZE and Aut 0 Note Autozeroing function is activated automatically for 10 min after switching on USER MANUAL 14 3 Pieces counting PCS 0 00 FF we 23 40 MENU v b PCS FF PCS 0 NZ This function enables to count identical pieces e g turnbuckles or buttons A measurement is performed in two phases first phase single piece weight calculation on the basis of defined pieces amount 5 10 20 50 100 200 or 500 pieces second phase pieces counting It is advised that single piece weight is not less than one reading unit and sample weight used in first phase is bigger than 100 reading units To leave function press MENU key and then with 7 lt key chose PCS and PCS 0 Note 1 Err 3 communicate signalises that a sample was not put on the pan The same communicate appears if single piece weight is less than one reading unit it is possible to count pieces but measuring error is bigger 2 To chose previously used pieces amount select in first phase in case no value was chosen error communicate appears 3 During pieces counting T lt key function does not change 4 In scales equipped with LCD display weighing unit is visible a
19. ation PAP Note This function is enable for special orders substitutable with other functions This function enables to calculate paperweight of Im of paper basing on samples of known area For quick access the function is accessible directly by pressing MENU key eS Ce Ce Note 0 0 TF s b 8 1 sun v gt F PAP gt T v F 1 gt T v D n 5 SE gim P0 02 gt T gt gm 81 1 The balance must be tared just before the measurement Place the specific sample quantity of the same area possible values 1 2 5 10 20 50 100 Press MENU key to access Function Menu To enter the function press Ale key when F PAP is displayed n is the number of samples placed on the pan To choose previously used value select option P is the area of a single sample It is possible to choose standard values 0 02 or 0 1g m or enter specific value CAT option To enter the value use the following keys Yy digit increase E decimal point gt T lt next digit MENU end The result of paperweight measurement is finished with mark pointing g m unit The balance is ready for the next measurements 1 Err 3 communicate signalises that a sample was not put on the pan The same communicate appears if single piece weight is less than one r
20. ble Each time after load is put on printout is performed measurement number result date and hour Accepting next measurement is possible after taking last load off For obtained measurement series scale calculates xX average mass as sum x n Min minimal mass in n samples Max maximal mass in n samples R Max Min the difference between max and min hoii 1 S standard deviation S Ste x n 1 5 defective samples count count of samples with mass Qn 2T1 lt x lt Qn T1 disqualifying samples count count of samples with mass lt Qn 2T1 Results of statistical calculations and histogram are printed on a printer Operation sequence Press MENU key 2 When F tP is displayed press gt T lt key The following options appear successively on display F 0 leave function F 1 measurements F 2 enter product data product code and batch size F 3 enter control parameters nominal mass Qn and measurement number F 4 select mode for data transmission automatic or manual 43 USER MANUAL Entering product data 3 Press gt T key when F 2 is displayed The following options appear successively on display Cod product code 6 digits n batch size out exit 4 Press gt T key when Cod is displayed Previously entered product code will be displayed one by one with out option In order to enter new product key press gt 7 lt key
21. cate appears on the display 35 USER MANUAL 0 00 MENU v dAtE gt T v Ab dAt O K dAt 2 gt T v h13 18 gt T GC JC v h13 19 6 be LZ b h13 SU d04 05 gt T r ef La r 09 sk v b 14 16 Function for setting date and time dAtE The function allows setting current date and time of scale internal clock and mode of its use The function has the following options dAt 0 deactivate date and time during printout of current weighing result dAt 1 activate date and time during printout of current indication E gt key dAt 2 change current date and time The example at the left presents how to set current date and time using dAt 2 option On successive positions digits are changing automatically or manually using gt 0 lt key several times In order to choose appropriate digit and move to the next position use gt Te key After setting proper date and time it should be activated with dAt option Time format h gg mm gg hour m minute Date format d mm dd m month d day Year format r 7r r two last year digits USER MANUAL 14 17 Function for selecting label number LAbEL The function appears in scales with ELT
22. d on the cable Connect the feeder to 230V Start up Leave the pan empty plug the feeder to the mains 230V 50Hz and plug the feeder connector to the 12V power socket at the back of the scale The scale proceeds with following start up actions HARAR Display test Z C Basic electronic components tests C Z C 2 C 6 C 6 W 5 Program version RA The scale is now ready to work 0 ma AUT fig USER MANUAL 9 General rules 1 Before each measurement make sure that zero indicator is displayed If zero indicator does not displayed or communicate appears press gt 0 lt key and wait until zero indication and zero indicator appears 2 The scale is equipped with a tare equal to its range To tare the scale press T lt key left or right Storing a tare value does not extend measuring range but only subtracts it from a load placed on a pan To make weight control easier and to avoid range overdrawing the scale is equipped with a load indicator graduated in percentages 3 Weighing result should be read when the indicator 4 lights which signalises stabilisation of a result 4 When the scale is not used but it is necessary to be ready to work immediately it can be switched off by pressing I O key The scale reading system is then switched off to standby mode signalled by the indicator OFF in version with the LCD display To sw
23. eading unit 48 USER MANUAL 15 Maintenance and small repairs 1 Keep the balance clean 2 Take care for during the operation some impurities may enter under balance base and into sensors vicinity In case of impurities finding remove them 3 In case of improper operation due to short power failure switch off the balance by unplugging the power cable from the socket and plug it again after a few seconds 4 The message Err b displayed after switching on the unloaded balance indicates the balance sensor mechanical damage 5 All repairs must be performed by the authorized personnel 6 To perform the repair contact the nearest service point Emergency messages Message Reason Recommendation c 1 6 over autotest negative result contact the service 1min Err b balance loaded during turning on remove load from the balance balance sensor mechanical failure contact the service l balance mechanical failure contact the service H balance overload remove load from the balance balance mechanical failure contact the service indicator does not work ma balance unstable base vibrations air blows place the balance in location assuring the indications stability balance damage contact the service tare setting not finished contact the service tare setting unsuccessful too low load or B G pressed zero the balance or pres B G again zeroing
24. eighing result is displayed in different format depending on the P amp C SC weight value of reference sample For hy weight values of reference sample d 0 3 5 of weighing range result is displayed in format 700 for range aot 3 5 35 in format 100 0 and KS above 35 in format 100 00 P8C 1 gt T sign is replaced with hy indicator v The function has the followin A 100 00 m PErC 0 disable the function K PErC 1 set current scale indication 95 00 as 100 and activate percentage weighing PErC 2 continue percentage weighing after exiting to normal weighing Note During percentage weighing gt T lt key has its normal function 26 USER MANUAL 14 10 Anti disturbance filter function FILtEr 0 00 MENU vib HLE gt T b FIL 0 NZ FIL 1 4 HL 2 HL 4 gt Te yb 0 00 27 This function allows using digital filter with selected intensivity during weighing Filter reduces the influence of mechanical vibrations air blasts base vibrations on measurement result Press MENU key and select FILtEr pressing gt T key The following options will be shown successively on display FIL 0 work without FIL 1 filter I weak FIL 2 filter II medium FIL 3 filter III sharp FIL 4 filter IV very sharp Select on
25. eters of weighting process Adding successively measurements to register is automatic and it occur after the scale is loaded and its indications stabilize After each loading printout is made with number of measurements result date and time Next measurement is made after taking off earlier load For the obtained measurements series the scale evaluates n number of samples sum x sum of all samples sum _ x yx x average value sum x n min minimal value from n samples max maximal value from n samples max min maximal value minus minima value Faus 1 E S standard deviation S gt o x Dr S srel variance factor srel x Statistical calculations results can be printed Order of operations Press MENU key When F StA is displayed press gt T lt key The following options are displayed F P statistical data printout F 0 out of function register zeroing statistic data printout F 1 enter or continue function Press gt T lt key when F is displayed Put on successively objects on pan remove after indication stabilization in order to add them to measurement register In order to obtain printed statistical results from measurements series press MENU key When sign E A4 is displayed press gt T lt key When F P is displayed press again T lt key 46 USER MANUAL This will cause printout of calculated statistics and histogram L
26. g to description below 16 bytes Byte 1 sign or space Byte 2 space Byte 3 4 digit or space Byte 5 9 digit decimal pont or space Byte 10 digit Byte 11 space Byte 12 k l c porspace Byte 13 g b t cor Byte 14 space Byte 15 CR Byte 16 LF Attention Network number different than zero F rS nr function changes scale working mode communication with a computer is possible after logging the scale in with 02h scale number command To log the scale out use 03h command For example Using a program to test RS232 interface program is available in www axis pl programy komputerowe for scale number 1 please write 020 to log in then S and write 03 to close communication USER MANUAL Scale tarring calling 7 lt key press Computer Scale S T CR LF 53h 54h 0Dh OAh Scale Computer without response Scale zeroing calling gt 0 lt key press Computer Scale S Z CR LF 53h 5Ah 0Dh OAh Scale Computer without response Scale turning on off calling O key press Computer Scale S S CR LF 53h 53h 0Dh OAh Scale Computer without response Entering to special function menu calling MENU key press Computer Scale S F CR LF 53h 46h 0Dh OAh Scale Computer without response Setting low threshold value option Computer Scale S L D DN CR LF 53h 4Ch D DN 0Dh 0Ah DI DN threshold value maximum 8 characters negati
27. h the scale Pay attention that supply voltage is compatible with specified technical data e Do not use the scale when its cover is opened e Do not use the scale in explosive conditions e Do not use the scale in high humidity e Ifthe scale seems not to operate properly unplug it from the mains and do not use until checked by authorised service 6 Environment protection According to legal regulations it if forbidden to dispose wasted electronic equipment in waste containers e Please return wasted scale to the point of purchase or other company specialised in recycling of wasted electronic components USER MANUAL LA Ne N 8 Preparation to work Take the scale out of the package removing protective foils Remove the lock nuts and unscrew lock screws replace them with scale legs Place the scale on a stable ground not affected by mechanical vibrations and airflows 4 Level the scale with the rotating rear legs so that the air bubble in the water level at the V back of the scale is in the middle Correct Wrong C 5 Put on the pan Plug the feeder connector to the power socket at the back of the scale and plug the feeder to the mains After self tests and result stabilisation the scale displays zero indication In scales with external feeder connect the feeder joint to supply socket situated on display column sometimes situate
28. in a byte bit 7 8 parity control PArItY 0 1 Odd 0 L network number when working in multistand computer system when working as a single scale the value should be 0 continuous transmission without using L gt key approx 10 results per second SEnd 0 1 Protocol Eltron automaticly activated function LAbEL To set desired transmission parameters activate Port function choose appropriate parameter and press Ale key to accept needed parameter value The example at the left presents how to set transmission speed value to 9600bps To leave the function choose out option USER MANUAL 14 6 Constant tare tArE This function enables to measure gross weight of a sample placed in a container of a known weigh value stored in the memory and to display calculated net weight of the sample Tare value is recalled from the memory with gt 0 lt key when the pan is empty Tare value may be entered using the keypad or by sampling container weight from the pan Operation sequence Caz 0 00 MENU Ee e h Aint Te e Prin O K Prin 1 FE 22 The following options are possible tAr 0 leave the function tAr l activate the function with the previous tare value tAr 2 sample tare value from the pan tAr 3 enter tare value with keys gt 0 lt
29. ing total and tot P 0 00 MENU option from menu v D totAL gt T The results are display in the following sequence total weight number of registered measurements n average value regarding that moving to display successive result is performed after pressing LF key In order to go back to total weighing without zeroing total register press E key third time d Che Cl eile 34 USER MANUAL To leave the function with clearing total register select total function from menu and choose tot 0 option When It will cause the scale prints the communicate informing about clearing registers The form of receipt after each measurement Date e Time measurement no weight measurement no weight Report form Date Time TOTAL WEIGHT NUMBER OF SAMPLES AVERAGE VALUE Note When the scale has not an internal clock Date and Time do not appear on printout Maximum number of measurements 99 999 Maximum total load 99 999 000d The weighing unit of the total value from the register Total is the same as the weighing unit stated on the keypad or is 1000 times greater what is signalled by o indicator at the left of the display If the registered value is too big to be displayed E communicate appears on the display If the number of series is too high and cannot be displayed Err1 communi
30. ion is stable Recz manual data transmission by operator using L gt key OUT exit 12 Choose appropriate option pressing gt T lt key 13 Press gt T lt key when out is displayed Measurements 14 Press MENU key IS When F tP is displayed press gt T lt key Select F 1 16 Printout is performed 17 Put successive good packages 44 USER MANUAL Successive results will be printed in table PLACE OF CONTROL Date with indication of their values using character referred to limit values SCALE TYPE FACTORY NO BATCH SIZE VALUE Qn VALUE Qn T1 VALUE Qn 2T1 18 After performing last measurement END text will appear and summarising report of control results will be printed Qn 2T1 Qn Qn 2TI x Ka Date M Time MEASUREMENT COUNT QUALIFYING AVERAGE STANDARD DEVIAT S HISTOGRAM lt Qn 2T1 Not Qn 2T1 A B C D E F 19 In order to finish working with the function and S reset results register press MENU key and when I F tP and F 0 is displayed press T lt key J Qn 2T1 e Note Activating TP function causes that indicators gt Qn 2T1 Hoy signal exceeding limit values Qn 2T1 and Qn 2T1 RESULT CONTROLLER 45 LA USER MANUAL 14 23 Statistical calculations function StAt Attention Function is available on demand and it replaces other special functions This function evaluates from series of measurements max 500 statistical param
31. itch the scale on press I O key The scale is immediately ready to operate maximum accuracy after self tests 5 Weighed sample should be placed in the centre of the pan Place the scale on a platform to avoid dropping weighed objects h on the pan Do not overload the scale more then 20 of maximum load Max 6 Protect the scale against dust aggressive dusts and liquids To clean the scale wash it with water with soap and dry it afterwards USER MANUAL 10 Balance checking It is advised to check scale indication accuracy before and after series of measurement using any load with known weight To check the scale with legal verification use a calibration weight with valid calibration certificate In case permissible error is exceeded it is advised to contact the nearest service to calibrate the scale 11 Scale adjustment To adjust a balance it is necessary to break protective marks therefore to calibrate the scale please contact the nearest service 12 Connecting to a computer or a printer optional The scale is equipped with RS232C or RS485 optional which can be used to connect external devices such as a computer or a printer Detailed way of communication data is defined by one of protocol LonG protocol to printer and computer ELtron protocol to label printer RxD receiver TxD transmitter GND When cooperating with a printer data is send automatically after result stabilisation but
32. nd 7 sign is replaced with pcs USER MANUAL 14 4 Printer cooperation settings Print lt 0 00 IMENU Activate the function for automatic SO e SW serial port working mode WwW hy cooperation with a printer After activation the scale prints Print pF aheader Weighing result with a successive measurement number is wW hy printed automatically after result stabilisation without using LF key To select computer cooperation mode Ne GE key activated and weighing results without successive numbers Prin 1 EF press MENU key then with 97 hy key chose Prin 0 and Prin 1 20 USER MANUAL 14 5 Serial port parameters setting Port 0 00 MENU v b Port FF v Port 0 a Port 1 F v baud gt F zv 4800 SF 9600 Ce vit bit D PArItY F rs Odd PF b Send gt F v by nr F v out F 21 The function enables to set the following transmission parameters standard parameters underlined transmission protocol Prot LonG printer ELtron label printer transmission speed bAud 1200 4800 9600 the number of bits
33. ndications will not be changing after 10 min time of c a 10 minutes the scale will 0 00 switch off remembering its settings zero and tare Switching on the scale is performed after pressing I O key 40 USER MANUAL 14 21 Density determining function dEnSIt The function allows determining 0 00 IMENU Solid density basing on its weight in v hy the air and in liquid of known density using the formula below dEnSt gt T m eer 8 liquid ad by m m m dEn 1 gt T lt where m weight in the air v hy m weight in liquid A 0 00 m3 hanger weight 8 liquid liquid density K By default A 100 00 g riia g cm WwW hy for distilled water When using liquid other than ey oe distilled water choose dEnS t from KS hy menu and use dEn 2 option to enter liquid density taking into 1 00 consideration its temperature v To enter value use the following 0 00 IMENU keys w gt 0 lt digit increase Es decimal point dEnSt gt T move to next digit MENU finish The measurement is performed in three phases measurement in the air measurement in liquid A dEn P lt GV GV a rae P 1 hanger weighing w To read density determination result
34. next transmission is possible after removing previously weighted sample Case RS485 option When protocol Long is chose scale sends result of weighting on an initialize signal from computer or after pressed a E key When automatic transmission mode is chose Pinout function LPt a printer data is send A automatically after result stabilisation but B Se next transmission is possible after removing previously weighted sample The scale sends following information successive number of weighing date and time if clock module is installed and weighing result During transmission communicate Print is displayed Case USER MANUAL Scale with Eltron protocol sending record of data after pressed gt key The scale sends following information number of label date and time if clock module is installed and weighing result During transmission communicate Label is displayed In special features scale can be equipped in second RS232 interface for additional functions ex continues transmit of indicate to second display Computer must have a special program for cooperation with a data from a scale This programs are procurement by Axis Detailed protocol description LonG protocol Communication parameters 8 bits 1 stop bit no parity baud rate 4800bps initialising signal data send order correspond to press L gt key Computer Scale S I CR LF 53h 49h 0Dh OAh Scale Computer scale response accordin
35. nter label forma must be designed in computer by Zebra Designer program and saved in printer Parameters and protocol of transmission must be compatible with printer label USER MANUAL 13 Basic function To make clear how to manage with each function in further part of instruction descriptions are replaced with pictures _ put a load on the pan la remove the load from the pan 2 30 FF press the key when indication is hy displayed Ww forced change SC automatic change 13 1 Normal weighing 0 00 fo Press 0 lt key gt T key in non legalized scales which zeros the hy scale operates only when the pan is empty 2 30 Weighing result should be read when the indicator 4 lights USER MANUAL 13 2 Weighing with tare 42 31 The scale is equipped with tare equal to its range Joint value tare and mass net can not cross a maximum of scale To display gross weight press B G key Note Press B G key to return to net weight indication Press HR key to display the weighing result for 5s with the highest readability possible This function is especially helpful in scales with legal verification with d e The weighing result with increased readability can be used for informational purposes only and cannot be printed or sent to a
36. t is smaller than lower threshold the scale signals MIN yellow colour between threshold values the scale signals OK green colour with the short sound signal greater than upper threshold the scale signals MAX red colour long sound signal The checkweighing results can be use to control optical indicator Indication mode batching devices Batching mode Standard scale is set for cooperation with optical indicator On outputs P1 P3 Relays socket short circuit states appear as result of comparison scale indication with threshold values On the chart below output states are shown during increasing load on the scale for both working modes Indication mode Batching mode P2 thr thr Il P3 thr Il zero treshold In Batching mode on P1 thr I and P2 thr II outputs short circuit impulses appears for time of 0 5s On P3 zero output short circuit state appears when indication does not exceed threshold value signalling zero load 31 USER MANUAL Relays connection diagram gnd Imax lt 100mA shield Relays output is the open collector transoptor output with load capacity 100mA 24V Transmitter inputs must be protected with diodes e g 1N4148 It is advised to use MS3K P electronic board sold separately consisting of RM96P transmitters with DC24V input voltage and AC250V 3A output Important notes 1 After switching the scale on both thresholds are set
37. tion in AC V function described in chapter 14 1 USER MANUAL 14 1 Menu customization function ACtIV and dEFAUL 0 00 MENU v b ACtlV PF v PCS WY Z Fort Is v b Port 0 Z Port 1 PF Among available user functions it is possible to select these which should be displayed after pressing MENU key It allows avoiding displaying whole list of available functions which makes operation time longer Operation sequence shown in the pictures on the left causes adding function for setting serial interface RS232C parameters Port to function menu After switching on ACTIV function a dot is displayed on the right side to distinguish from regular menu Chosen functions are displayed with a dot on the left side In every moment it is possible to restore primary manufacture settings choosing dEFAULt special function In order to remove function from menu in the last operation in place of selecting Port 1 choose Port 0 USER MANUAL 14 2 Autozeroing function AutoZE lt 0 01 A MENU z Auto ZE PF v Aut 0 NZ Aut 1 F lt Es 0 00 b When F Aut function is activated the scale automatically ensures stable zero indication if the pan is empty or if zero indication was acquired by pressing
38. to maximum values 2 When setting upper threshold value pay attention that its value is not below lower threshold value 3 Setting lower and upper threshold value is possible after sending appropriate orders from computer what is described in scale user manual 32 USER MANUAL Operation sequence Press MENU key and choose thr SEO 0 00 MENU pressing T lt key Ee v hy The following options are displayed successively thr T lt thr 0 deactivate the function v hy thr 1 activate the function thr P check last threshold values thr O press LE key several times thr t choose Relays socket mode K 0 exit to weighing 1 Batching mode thr 1 ad Bs 2 Indication mode w hy Choose thr loption using gt 7 lt key The following options for entering 1 gt 7T thresholds are displayed SEt 0 go to weighing with v hy signalling threshold excess SEt set lower threshold value 20 SEt 2 set upper threshold value eee hy SEt 3 set zero signalisation threshold D Using gt Te key select SEt option w hy Set lower threshold value using the following keys 5 s0 lt 0 lt digit increase y hy decimal point T lt move to next digit 50 MENU MENU finish
39. ve value digits dot decimal separator number of digits after dot should be the same as on scale display Scale Computer without response Example in order to set low threshold 1000g in scale B1 5 d 0 5g the following order should be sent SL1000 0CRLEF 53h 4Ch 31h 30h 30h 30h 2Eh 30h ODh OAh in order to set low threshold 100kg in scale B150 d 50g the following order should be sent SL100 00 CRLF 53h 4Ch 31h 30h 30h 2Eh 30h 30h ODh OAh Setting high threshold value option Computer Scale S H D DN CR LF 53h 48h DI DN 0Dh OAh DI DN threshold value see Scale Computer without response Connecting cable WK 1 scale computer 9 pin interface WAGA KOMPUTER a lo 2A 34 40 54 o 70 8o USER MANUAL Protocol ELTRON description Communication parameters 8bits 1stop no parity 9600bps After use L key scale send Scale Label printer EPL 2 language instruction to initialize print of label US control instruction FR 0001 number of labels L starting instruction hh mm 5 signs hours minutes yyyy mm dd 10 signs year month day mass unit 10 signs scale indicate mass unit P1 ending instruction Attention 1 It is possible to place a constants sign company name product name 2 The default number of label s is 0001 label number 1 Different numbers of label are possible by using a LADEL function 3 Label formula must be saved in pri
40. when previous code is displayed and after appears use keys 0 lt change digit gt T move to next digit MENU finish If previous code is valid choose out pressing 7 lt key 5 Press gt T key when n is displayed Previously entered batch size will be displayed one by one with out option In order to enter new batch size press gt T lt key when previous value is displayed using keys gt 0 lt T and MENU as above 6 Press gt T key when out is displayed Entering control parameters 7 Press gt T key when F 3 is displayed The following options appear successively on display O_n nominal mass Qn 20 60 100 160 n select available measurement quantity total quantity of samples out exit 8 Press gt T key when O_n is displayed Previously entered nominal mass will be displayed one by one with out option In order to enter new nominal mass press Ale key when previous value is displayed using keys 0 lt T and MENU as above 9 Select measurement quantity pressing Ale key Selected quantity should comply with requirements of good packaging act of law it depends on control kind and batch size Letter n denotes full control 10 Press gt T key when out is displayed Selecting mode for data transmission Il Dress gt T key when F 4 is displayed The following options appear successively on display Auto automatic data transmission after scale indicat
41. with too high load set the tare 49 USER MANUAL Declaration of Conformity We AXIS Sp ka z 0 0 80 125 Gdansk ul Kartuska 375B declare with full responsibility that the balances B60P marked with CE mark are consistent with 1 Standard PN EN 61010 1 2004 Safety requirements for electrical equipment for measurement control and laboratory use General requirements harmonized with the directive 73 23 EEC Low Voltage Directive 2 Standard PN EN 55022 2000 Electromagnetic compatibility EMC Information technology equipment Radio disturbance characteristics Limits and methods of measurement and PN IEC 61000 4 3 Electromagnetic compatibility EMC Part 4 3 Testing and measurement techniques Radio frequency electromagnetic field immunity test harmonized with 89 336 EEC directive electromagnetic compatibility Moreover balances with the following information on rating plates sticker with two digits of year of conformity assessment and with C M number of notified unit performing the assessment XX 1443 green metrological marking M protective mark from notified unit are made according to certificate of approval EC no PL 04 020 and have EC verification confirming conformity with 3 Standard PN EN 45501 Specification for metrological aspects of non automatic weighing instruments issued in December 1999 harmonized with the 90 384 EEC council directive changed by
Download Pdf Manuals
Related Search
Related Contents
Graco 313289S User's Manual Service Manual 画チョコレートウォーマー無料修理{呆言正害 Here`s - DiscreetFX Centre aquatique - La Piscine - Rue des Olympiades 22400 VaVeliero CARBO4 mobile phone case Lessons to Print For Using AAC2go with the Go Talk Now App Copyright © All rights reserved.
Failed to retrieve file