PT-500 Modbus Series User Manual

image

Contents

1. G Cable Length specify length of cable needed in feet H Accuracy No4 0 25 N1 0 25 with NIST certification N2 0 1 with NIST certification Note Indicates this option is standard Note Indicates this option does not yet have CSA Approvals BINMASTER 402 434 9102 www binmaster com info binmaster com Electrical Pinout Table Supply Power Table and System Wiring Diagrams PT 500 Modbus Serie s Pinout Table PT 500 Modbus Series Supply Power Table Modbus Modbus Pigtail Power Power Supply 5 28 VDC Power B TX A TX Shield Case Gnd Modbus System Wiri Power 5 28 Vdc Supply an Master RS 485 A TX Device RS 485 B TX Note PT 500 modbus sensors use reversed TX TX pins When connecting series sensor to your system ensure continuity of TX to TX and TX to TX rather Ato A and BtoB ng Use Shielded Cable 120 Q terminating resistor PT 500 modbus series sensor PT 500 modbus series sensor PT 500 modbus than Sensor 2 Sensor 3 Sensor 1 120 Q terminating resistor at last sensor Modbus System Wiring with RST 6001 Power 5 28 Vdc GND Use Shielded Cable RST 6001 Modbus Controller USB to computer with the Modbus software Note An independent 5 28 Vdc power supply is required w
2. 402 434 9102 www binmaster com info binmaster com BINMASTER Introduction Thank you for purchasing a PT 500 modbus series submersible pressure transmitter from BinMaster We appreciate your business Please take a few minutes to familiarize yourself with your PT 500 and this manual PT 500 submersible pressure transmitters offer reliability in harsh industrial conditions The small size integrated electronics wide operating temperature range and durability make the PT 500 the perfect instrument for static and dynamic pressure measurement Reading your label The PT 500 comes with a label that includes the instrument s model number part number serial number and a wiring pinout table Please ensure that the part number and pinout table on your label match your order BINMASTER 402 434 9102 www binmaster com info binmaster com Warranty and Warranty Restrictions BinMaster warrants this product against defects in material and workmanship for two 2 years according to the following terms 1 This warranty extends to the original purchaser only and commences on the date of original purchase 2 BinMaster s sole obligation under said warranty is to repair or at its option replace the defective parts The buyer shall have no other remedy All special incidental and consequential damages are excluded The buyer must deliver the product under warranty prepaid to the factory BinMaster s obligation is limited to the co
3. 40401 40402 40403 40404 40405 40406 40436 40437 40438 40439 40440 40441 Application 11 Strapping Chart Polynomial Values Register 40400 40401 40402 40403 40404 40405 40406 40436 40437 40438 40439 40440 40441 40440 40441 EBINMASTER Function Device Address Units Application Type Volume Units Decimal Calculated Max Level Full Level Tank Length Tank Depth Tank Width A Full Level Value Range 1 to 247 10 1 7 0 3 factory set 0 65 535 mm 0 1 000 000 mm O 1 000 000 mm O 1 000 000 mm Function Value Range Device Address 1 to 247 Units 1 Feet 2 Inches 3 Meters Application Type 11 Volume Units 1 7 Decimal Calculated 0 3 Max Level factory set Full Level 0 65 535 mm X43 Coefficient O 1 000 000 XA2 Coefficient O 1 000 000 XA1 Coefficient O 1 000 000 X 0 Coefficient O 1 000 000 402 434 9102 www binmaster com info binmaster com 15 Chapter 4 Maintenance General Care Your PT 500 series pressure transmitter is very low maintenance and will need little care as long as it is installed correctly However in general you should For process connected sensors keep the transmitter and the area around it generally clean e Avoid applications for which the transmitter was not designed such as extreme temperatures contact with incompatible corrosive chemicals or other damaging environments e Inspect the threads whenever you remove t
4. 4 Figure 4 2 NOTE Desiccant crystals change from blue to pink as they become saturated Car tridge must be replaced when all crystals have saturated e Repair and Returns Should your PT 500 series pressure transmitter require service please contact the factory We will issue you a Return Material Authorization RMA number with instructions Phone 402 434 9102 Email info binmaster com Please have your PT 500 s part number and serial number available See Warranty and Warranty Restrictions for more information BINWASTER 402 434 9102 www binmaster com info binmaster com 17 BINMASTER 402 434 9102 www binmaster com info binmaster com
5. Units Determines the units of measure for the calculated reading 0 PSI 5 mmH20 10 mmHG 14 inSW 1 BAR 6 cmH20 11 cmHG 15 inSW 2 mBAR 7 mH20t 12 inHG 16 msw 3 kPa 8 inH20 13 kg cm 4 MPa 9 ftH20 t All H2O pressure measurements 20 C All HG pressure measurements Q 0 C 40402 Application Type Determines the units of measure for the calculated reading 0 Standard units selected in 40401 are displayed 8 Custom units selected in 40401 and multiplier in 40436 40437 are used to compute desired units description in 40438 40439 is label for measurement PT 500 Modbus Sensor Parameters L31 level series 40401 Units Determines the units of measure for the calculated reading when Application Type is set to 0 1 or 7 1 Feet 2 Inches 3 Meters 40402 Application Type Determines the type of calculated reading performed by the sensor 0 Distance 1 Level 2 Standing Cylindrical Tank with or without Hemispherical Bottom 3 Standing Cylindrical Tank with or without Conical Bottom 4 Standing Rectangular Tank with or without Chute Bottom 5 Horizontal Cylindrical Tank with or without Spherical Ends 6 Spherical Tank 7 Pounds Linear Scaling 8 N A 9 Vertical Oval Tank 10 Horizontal Oval Tank 11 Strapping Chart 10 402 434 9102 www binmaster com info binmaster com EBINGASTER 40403 Volume Units Determines the units of measure for the calculated
6. 000 000 mm O 1 000 000 mm 0 1 000 000 mm lt Length Application 6 Volume of Spherical Tank Register 40400 40401 40402 40403 40404 40405 40406 40436 40437 EBINMASTER Function Device Address Units Application Type Volume Units Decimal Calculated Max Level Full Level Tank Diameter Value Range 1 to 247 6 1 7 0 3 factory set 0 65 535 mm O 1 000 000 mm 402 434 9102 www binmaster com info binmaster com 13 Application 7 Pounds Linear Scaling Register 40400 40401 40402 40403 40404 40405 40406 40436 40437 Function Device Address Units Application Type Volume Units Decimal Calculated Max Level Full Level Multiplier linear scalar Application 9 Volume of Vertical Oval Tank Register 40400 40401 40402 40403 40404 40405 40406 40436 40437 40438 40439 40440 40441 Function Device Address Units Application Type Volume Units Decimal Calculated Max Level Full Level Tank Length Tank Depth Tank Width Value Range 1 to 247 1 Feet 2 Inches 3 Meters 7 0 3 factory set 0 65 535 mm O 1 000 000 1000 1 000 Value Range 1 to 247 9 1 7 0 3 factory set 0 65 535 mm 0 1 000 000 mm 0 1 000 000 mm O 1 000 000 mm 402 434 9102 www binmaster com info binmaster com EINHASTER Application 10 Volume of Horizontal Oval Tank Register 40400
7. R k AR KAK AK AKAR AKAR ARA AKA AA RRA 6 Modb s PLOGLAM ING i ox xizak kii korek ka k rka diki cika kt av ki xa b ar xas nee kak eu YER k n ko kk Ok baki vu 6 Modbus Programming with RST 6001 and BinMaster Modbus Software 6 PT 500 Modbus Register Lists cccscsssssecsexsosstnesnssssitonansosnasesenseostarsnsbtisons uvsnschcnsswanstmnessensiosers 7 9 PT 500 Modbus Sensor Parameters L5 pressure S I S u umEmEmammnmamekmkke kek kek kirk kk 10 PT 500 Modbus Sensor Parameters L31 level series E mEmmmEmmnmmkekmkmknkekkkkk kek n 10 PT 500 Modbus Application Parameters L31 level series 11 15 Chapter 4 Maintenance cccccssccsssessseeseeseseseseeeseeseeseeaeeseeeeesseeeseseesessaeeseeeaes 16 General Care Gene ER nn n n n Vee een kk k kk k n n ee 16 Vent TALE DIVIN wi un sa bois kes ki bayeki yasak ah ka ky e ndi a v ya da VE VR SEH N ke y ARES 16 17 Repair and RetUlIT1S mEmmmammnnekenkek nnn kek n kk k KA KAK A AA AK AK A AA KA rk kk kk nnmnnn nnmnnn kan k Ak Ak kak Ak RR 17 NOTE Wiring information in this User Manual is specific to the Modbus Series of the PT 500 If you have a 0 5V mV V or 4 20 mA Series sensor please consult the factory at 402 434 9102 or our website at www binmaster com literature for the appropriate man ual for your sensor
8. up to 20 PT 500 L5 or PT 500 L31 sensors Through BinMaster Modbus software you can monitor the raw readings from the sensor including level or pressure temperature and battery voltage or configure the sensor See PT 500 Modbus Register Lists below NOTE For BinMaster Modbus programming instructions or to download BinMaster Modbus software please visit www binmaster com e PT 500 Modbus Register Lists Input Registers 0x04 Register Returned Data 30299 Model Type 30300 Pressure L5 PSI L31 mmH O 30301 N A 30302 Temperature Reading in C signed 30303 30304 Calculated raw 30305 30306 N A 30307 N A 30308 Battery Voltage 30309 Trip 1 Status 30310 Trip 2 Status NOTE The Calculated Readings will be returned without a decimal place In order to obtain the true result the Decimal Place setting must be taken into account BINMASTER 402 434 9102 www binmaster com info binmaster com Holding Registers 0x03 PT 500 L5 pressure series Register 40400 40401 40402 40403 40404 40405 40406 40407 40408 40409 40410 40411 40412 40413 40414 40415 40416 40417 40418 40419 40420 40421 40422 40423 40424 40425 40426 40427 40428 40429 40430 40431 40432 40433 40434 40435 40436 40437 40438 40439 40446 40447 40448 40449 40450 40451 40452 40453 40454 Function Device Address Units Application Type N A Decimal Calculated Max Pressure Full Pressure Zero Offset Pressu
9. 44 40445 40446 40447 40448 40449 40450 40451 40452 40453 40454 Function Device Address Units Application Type Volume Units Decimal Calculated Max Level Full Level Zero Offset N A A D Gain Specific Gravity Parameter Default Averaging Calibration Value Calibration Flag Sample Rate Scale Offset Voltage Offset Baud Rate Parity Stop Bit Pressure X43 Pressure X42 Pressure X 1 Pressure X40 Trip 1 Level Trip 1 Window Trip 1 Type Trip 2 Level Trip 2 Window Trip 2 Type Parameter 1 Parameter 2 Parameter 3 Parameter 4 Parameter 5 Temperature Offset Temperature X43 Temperature X42 Temperature X41 Temperature X40 Setting is factory calibrated Do not adjust SINVASTER Value Range 1 to 247 1 Feet 2 Inches 3 Meters 0 11 1 7 0 3 0 65 535 mm 0 65 535 mm 0 610 mm 1 2 4 8 16 32 64 128 1 2 000 0 No 1 Restore Defaults 0 10 0 65 535 0 300 10 to 1000 milliseconds 0 65 535 20 000 20 000 20 20 0 3 2400 9600 19200 0 2 none even odd 0 1 0 1 stop bit 1 2 stop bits N A N A N A N A 0 65 535 mm 0 65 535 mm 0 29 0 65 535 mm 0 65 535 mm 0 29 0 1 000 000 mm 0 1 000 000 mm 0 1 000 000 mm 0 1 000 000 mm 0 1 000 000 mm 20 20 N A N A N A N A 402 434 9102 www binmaster com info binmaster com e PT 500 Modbus Sensor Parameters L5 pressure series 40401
10. 50 88 9mm a PT 500 with Reusable Cage i 5 29 134 4mm 11 2 SANITARY FITTING man 50 3mm PT 500 with Tri clover Sanitary Fitting 7 40 187 9mm NON REMOVABLE SENSOR CAGE ASSEMBLY 2 24 56 9mm 3 50 88 9mm PT 500 with Welded Anti snag Cage ry 6 44 163 5mm PROTECTIVE 0 188 THRU CONE a1 00 25 4mm PT 500 with Removable Plastic Nose Cone BINMASTER 402 434 9102 www binmaster com info binmaster com Specifications Performance Pressure Ranges Digital Output Over Pressure Burst Pressure 1 Year Stability Accuracy Linearity Hystereses amp Repeatability Thermal Zero Shift 70 F Thermal Span Shift 70 F Environmental Operating Temperature Compensated Temperature Maximum Submersible Depth Electrical Supply Voltage at sensor Current Draw Protection Load Limitation Startup Time Materials of Construction Wetted Materials Anti snag Cage Cable Protective Nose Cone Mechanical Pressure Connection Cable Tensile Strength Patents US Patent No 7 787 330 402 434 9102 www binmaster com info binmaster com 0 to 300 PSIG Modbus RTU 4 wire RS 485 2X FSO 3 0X FSO 0 75 FSO 0 25 of Full Scale BFSL up to 0 1 of Full Scale 0 045 FSO C 0 025 FSO F 0 045 FSO C 0 025 FSO F 40 to 85 C 40 to 185 F 17 to 54 C 0 130 F 462 2 ft 140 88 m 300 psig 5 28 VDC 2 mA ma
11. PT 500 Modbus Series User Manual BINMASTER Rev A 03 15 Table of Contents IrltIOQ UC LA o n a a l iene irl aica kar k xa k na Sul kk anada i e kun dkan kun X ku e wl r u i PR NON ener Ku n k Meee iii Warranty and Warranty Restrictions scsecssseessesseeeseesseeesesneesseesneenenees iv Chapter 1 Specifications and Option csccsssscsesseessesesseeseeseesesenesaeeeseees 1 Dim T STOL Se ki Rae ee ere ee a a w kak ARA a ku anak a KOLA du ku ee k a kk KOKA KAK K kak kaka 1 AGE L l LOM SEVAN DUN kn n e kr PrN kk e pann r n n gg 2 Model Number ConfigUFatOFI 042ettettetertetttettaaseteasesaasasaaensasanssnnnsonoananannanannnnnnnnnannnnonnnnn 3 Electrical Pinout Table Power Supply Table and System Wiring Diagrame 4 Chapter 2 Installation and Removal Procedures and Notes 5 Tools Li gt s1 o gt 1 RIN WE a et kk on lr sneer rte ttre oh ii n ur kk nC oS pe aie 5 Mounting Instructions 2 ccceccecececeeceeeeseeceeeeseeneeeeseesceneseeseeaeeeeaeseeaeeaesaesaeesaeeeeeeseeneeeeeeataeses 5 po F test Cote MB ote Lo 4 ii oui eer kaya n ayd b ede v diken k r n n ee anaE Ea Sk Ke Ka w k wa D eee dae kas 5 Removal In SWE ING c k bon akila yo fk keka kaka hakan ka k ya za Wan ka a kura k k k ki k k n ao a lak n kain 6 Chapter 3 Programming a ie it inik tk kk on bi a e n kak ak
12. al Calculated Max Level Full Level Tank Diameter Cone Diameter at bottom of cone Length height of Cone Value Range 1 to 247 3 1 7 0 3 factory set 0 65 535 mm 0 1 000 000 mm O 1 000 000 mm 0 1 000 000 mm Diameter Cone Length yi n Cone Diameter Application 4 Volume of Standing Rectangular Tank Chute Bottom Register 40400 40401 40402 40403 40404 40405 40406 40436 40437 40438 40439 40440 40441 40442 40443 40444 40445 Function Device Address Units Application Type Volume Units Decimal Calculated Max Level Full Level Tank X Dimension Tank Y Dimension Chute X Dimension Chute Y Dimension Length height of Chute Value Range 1 to 247 A 1 7 0 3 factory set 0 65 535 mm 0 1 000 000 mm O 1 000 000 mm 0 1 000 000 mm 0 1 000 000 mm 0 1 000 000 mm 402 434 9102 www binmaster com info binmaster com Full Level Length Chute X EINHASTER Application 5 Volume of Horizontal Cylindrical Tank Hemispherical Ends Register 40400 40401 40402 40403 40404 40405 40406 40436 40437 40438 40439 40440 40441 Function Device Address Units Application Type Volume Units Decimal Calculated Max Level Full Level Tank Length Tank Diameter Radius of End Hemispheres Diameter End Radius Value Range 1 to 247 5 1 7 0 3 factory set 0 65 535 mm O 1
13. an RST 6001 Modbus Controller The RST 6001 can only supply the 5 28 Vdc required by the modbus series PT 500 Equivalent 120 Q terminating resistor internal to RST 6001 PT 500 modbus series sensor PT 500 modbus series sensor PT 500 modbus series sensor Sensor 1 v 2 Sensor 2 v hen using 5 Vdc not 120 Q terminating resistor at last sensor 402 434 9102 www binmaster com info binmaster com BINMASTER Chapter 2 Installation and Removal Procedures and Notes Tools Needed Wrench sized appropriately for your PT 500 s process or conduit connection Thread tape or sealant compound for threaded connections e Mounting Instructions Your PT 500 can be mounted in three ways via NPT process connection free hanging suspension or con duit mounted Mounting your pressure transducer is easy if you follow a few simple steps e Never over tighten the sensor In all cases tighten the sensor as little as possible to create an adequate seal e Always use thread tape or sealant compound on tapered threads Wrap thread tape in the opposite direction of the threads so it does not unravel as you screw the sensor into place Unraveling can cause uneven distribution and seal failure Always start screwing in your sensor by hand to avoid cross threading Thread failure can be a problem if you damage threads by over tightening them or by crossing thread
14. he transmitter from duty or change its location e Avoid touching the diaphragm Contact with the diaphragm especially with a tool could permanently shift the output and ruin accuracy e Clean the diaphragm or the diaphragm bore with extreme care If using a tool is required make sure it does not touch the diaphragm IMPORTANT Any contact with the diaphragm can permanently damage the sensor Use extreme caution Vent Tube Drying Condensation in the vent tube can damage the electronics in your sensor resulting in unreliable readings BinMaster offers two methods of preventing vent tube condensation a venting cap and a desiccant drying cartridge The venting cap is a PVC tube with a hydrophobic patch that allows moisture to pass out of the tube without allowing water in See Figure 4 1 The cap is sealed by an o ring and is easily installed in the field The desiccant drying cartridge with vent tube adapter absorbs any moisture in the vent tube to keep vapor from condensing See Figure 4 2 The installation of the desiccant drying cartridge is quick and easy Common installation methods are cable tie Velcro and cable clamps IMPORTANT Do NOT use desiccant cartridge in the presence of vapors or liquids con taining phosphate esters synthetic lubricants hydrocarbon solvents methanol acetone lacquer solvents or other organics 402 434 9102 www binmaster com info binmaster com BINMASTER Figure 4 1 li
15. r with an appropriately sized wrench per your process connection For suspended sensors retrieve the sensor from the vessel Follow any and all procedures for safely isolating any media contained inside the line or vessel e Carefully clean the sensor s fitting and diaphragm of any debris see General Care and inspect for damage e Store your sensor in a dry place at a temperature between 40 F and 180 F gi DANGER Removing your process connected PT 500 Pressure Transmitter while there is still pressure in the line could result in injury or death IMPORTANT Any contact with the diaphragm can permanently damage the sensor Use extreme caution Chapter 3 Programming Modbus Programming PT 500 L5 L31 modbus series sensors use standard Modbus RTU protocol RS 485 The sensors can only op erate as slave devices Sensor default transmission settings are 9600 Baud 8 Bits 1 Stop Bit No Parity and require a minimum delay of 300 ms between transactions to return the contents of all registers Commands returning fewer registers will require shorter delays See PT 500 Modbus Register Lists on pages 7 9 NOTE For more information about Modbus RTU please visit www modbus org 6 402 434 9102 www binmaster com info binmaster com BINMASTER e Modbus Programming with RST 6001 and BinMaster Modbus Software BinMaster RST 6001 Modbus Controller can be used in tandem with BinMaster modbus software to program and control
16. re Decimal A D Gain N A Parameter Default Averaging Calibration Value Calibration Flag Sample Rate Scale Offset Voltage Offset Baud Rate Parity Stop Bit Pressure X43 Pressure XA2 Pressure X41 Pressure X 0 Trip 1 Pressure Trip 1 Window Trip 1 Type Trip 2 Pressure Trip 2 Window Trip 2 Type Multiplier Description Temperature Offset Temperature X43 Temperature X42 Temperature X 1 Temperature X40 Setting is factory calibrated Do not adjust Value Range 1 to 247 0 16 0 or 8 0 3 0 32 000 PSI 0 32 000 PSI 15 000 30 000 PSI 0 3 1 2 4 8 16 32 64 128 0 No 1 Restore Defaults 0 10 32 767 32 767 0 300 10 to 1000 milliseconds 0 65 535 20 000 20 000 20 20 0 3 2400 9600 19200 0 2 none even odd 0 1 0 1 stop bit 1 2 stop bits N A N A N A N A 15 000 30 000 PSI 0 30 00 PSI 0 29 15 000 30 000 PSI 0 30 00 PSI 0 29 0 0010 99 9999 float A Z 0 9 16 char 20 20 N A N A N A N A 402 434 9102 www binmaster com info binmaster com BINMASTER Holding Registers 0x03 PT 500 L31 level series Register 40400 40401 40402 40403 40404 40405 40406 40407 40408 40409 40410 40411 40412 40413 40414 40415 40416 40417 40418 40419 40420 40421 40422 40423 40424 40425 40426 40427 40428 40429 40430 40431 40432 40433 40434 40435 40436 40437 40438 40439 40440 40441 40442 40443 404
17. reading when Application Type is set to 2 6 or 9 11 1 Feet 5 Liters 2 Million Feet 6 Inches 3 Gallons 7 Barrels 4 Meters e PT 500 Modbus Application Parameters L31 level series Application 0 Distance Register 40400 40401 40402 40403 40404 Application 1 Level Register 40400 40401 40402 40403 40404 Function Device Address Units Application Type Volume Units Decimal Calculated Function Device Address Units Application Type Volume Units Decimal Calculated Value Range 1 to 247 1 Feet 2 Inches 3 Meters 0 0 3 Value Range 1 to 247 1 Feet 2 Inches 3 Meters 1 0 3 Application 2 Volume of Standing Cylindrical Tank Hemispherical Bottom Register 40400 40401 40402 40403 40404 40405 40406 40436 40437 40438 40439 SINVASTER Function Device Address Units Application Type Volume Units Decimal Calculated Max Level Full Level Tank Diameter Radius of Bottom Hemisphere Value Range Diameter _ 1 to 247 lt 2 1 7 0 3 factory set 0 65 535 mm 0 1 000 000 mm 0 1 000 000 mm Bottom A Radius 402 434 9102 www binmaster com info binmaster com 11 Application 3 Volume of Standing Cylindrical Tank Conical Bottom Register 40400 40401 40402 40403 40404 40405 40406 40436 40437 40438 40439 40440 40441 Function Device Address Units Application Type Volume Units Decim
18. s e For suspension mounting the PT 500 drill a 3 16 hole into a 1 2 NPTF to 1 2 NPTF hex coupler and secure it to the 1 2 NPTM coupler fitting of the PT 500 Attach a 060 diameter 316L SS cable of de sired length to the hex coupler and secure the steel cable according to your application requirements NOTE If your PT 500 has a vent tube do not seal cover or close the vent tube with anything other than an BinMaster provided venting cap or desiccant drying cartridge See Figure 4 1 and 4 2 Unapproved seals or covers will prevent proper sensor operation e Electrical Installation e Attach the wires of your PT 500 to your control system according to the pinout table above IMPORTANT The PT 500 uses reversed TX TX pins When making connections between this sensor and RST modules ensure continuity of Ato A and B to B pins When connecting the PT 500 to other systems ensure continuity of TX to TX and TX to TX BINMASTER 402 434 9102 www binmaster com info binmaster com Removal Instructions Removing your PT 500 from service must be done with care It s easy to create an unsafe situation or damage your sensor if you are not careful to follow these guidelines For sensors installed via NPT process connection make sure the pressure is completely removed from the line or vessel Follow any and all procedures for safely isolating any media contained inside the line or vessel e Remove the senso
19. st of material and labor to repair or replace and does not include transportation expenses 3 This warranty shall be voided in our sole judgment by alterations of equipment except by BinMaster or tampering with improper installation or maintenance accident or misuse or act of God This warranty expressly excludes all damage to the product resulting from careless or neglectful packaging or transportation The warranty does not extend to repairs made necessary by normal wear 4 This warranty is in lieu of all other warranties expressed or implied including any implied warranties or merchantability or fitness for particular purpose No employee agent franchise dealer or other person is authorized to give any warranties of any nature on behalf of BinMaster 5 BinMaster shall in no event be responsible for any warranty work done without first obtaining BinMaster s written consent 6 Except as provided herein BinMaster shall have no liability loss or damage caused or alleged to be caused directly or indirectly by this equipment 7 This warranty gives the buyer specific legal rights and you may also have other rights which vary from state to state 8 For service please call 402 434 9102 iv 402 434 9102 www binmaster com info binmaster com BINMASTER Chapter 1 Specifications and Options Dimensions i 7 14 181 3mm REMOVABLE SENSOR CAGE ASSEMBLY i 2 00 50 8 _t L 93
20. x Reverse Polarity and Surge per IEC 61000 4 5 Remax V 12V 0 02A 0 0420 per ft of cable max 200 ms 316L Stainless Steel 316L Stainless Steel Urethane PVC or Hytrel Delrin See model number configurator for complete list Up to 200 pounds EINHASTER Model Number Configurator Part Number PT 500 A B C D A Cable Type Urethane Blue with vent tube PVC Black no vent tube sealed unit Hytrel 31 Black with vent tube PVC Black with vent tube Hytrel 25 Black with vent tube gn gt B Pressure Range Specify range in desired unit of measure Max Water Depth 462 2 ft 140 9 m 300 psig C Standard Units of Measure PSI FTH20 INWC INH20 MMH20 FWC D Output L14 4 20 mA 2 wire L3 0 5V 4 wire Lo mV V 4 wire L10 0 10V 4 wire L5 Modbus RTU 4 wire RS 485 Pressure reading only L31 Modbus RTU 4 wire RS 485 Level calculations tank volume E Overmold n EO No overmold for 1 2 NPTM fitting for conduit E37 Pigtail with overmolded cable F Process Connection P14 1 2 NPTM with removable plastic nose cone P5 1 4 NPTF P37 Welded Cage anti snag 1 piece fitting P38 1 1 2 tri clover with 3 4 diaphragm P39 Reusable Cage includes P38 fitting