Home

Non-Contact Infrared Thermometer

image

Contents

1. the chamber lid and change the batteries taking care with ts z x the correct positive and negative direction A 4 mistake with this could cause damage ae to the unit and compromise the guarantee of your Non Contace Infrared Thermometer The Thermometer operates on single usage batteries only do not use rechargeable batteries Technical Specifications 1 Normal use condition Ambient temperature 50 F 104 F 10 C 40 C Relative humidity lt 85 Power DC 3V 2 pcs AAA batteries Unit size 5 1 x1 8x2 2in 130x45x55mm L x W x H Unit weight 75g without batteries Temperature display resolution 0 1 F 0 1 C DBP Measuring range Body mode 89 6 F 109 2 F 32 C 42 9 C Under Body mode there are three color backlits Green color backlit lt 99 1 F 37 3 C which indicates normal temperature Orange color backlit 99 3 F 100 2 F 37 4 C 37 9 C which indicates low fever Red color backlit gt 100 4 F 38 C which indicates high fever In surface mode 32 F 140 F 0 C 60 C Room mode 50 F 104 F 10 C 40 C 7 Precision 89 6 F 96 6 F 32 0 C 35 9 C 0 6 F 0 3 C 96 8 F 102 2 F 36 0 C 39 0 C 0 4 F 0 2 C 102 4 F 109 2 F 3 rC 42 9 C 0 6 F 0 3 C 8 Power Consumption lt 150mW 9 Measuring distance 1 2in 2in 3cm Scm 10 Automatic power off 30 secs Non Contact Infrared Thermometer Precision The Non Contact Infrared Therm
2. 4 99 5 NCT 301 does not take responsibility for the results or actions of non medical personnel using the non contact infrared thermometer ee LCD panel eafcy TfG gt me meter INon Contact Infrared Therm 0X Model No NCT 301 i Batteries 2xAAA 1 5V 3V k Celsius or Fahrenheit Measuring Distance 1 2 2in Made Mode Settings and Function of Menu 1 Switch on the thermometer Press the SCAN button one second after the screen panel in full display it will enter the standby mode with the sign F Then press the SCAN button again you will get the measuring result in 1 second But if there is no more operation it will turn off in 30 seconds automatically 2 Setting the buzzer Under standby state press to turn on or turn off the buzzer the display shows ON or OFF respectively after setting 3 Setting the Mode There are three modes with this thermometer Body Surface and Room Under standby state The screen displays Boby F Press again the screen will display Surface Temp F Press again the screen will display Room F Note The NCT 301 default is set to BODY mode 4 Setting the Temperature Unit Under standby state Press the cr F button to switch between Celsius and Fahrenheit 5 Viewing measurement history Under standby state Press MEM button the last temperature will be displayed you can view the last 32 measurements chronologically by going
3. Please read carefully this manual before use Features 1 Specially designed to take the Human Body Temperature at a distance of 1 2 to 2in 3cm to 5cm from forehead It can also be used to take object surface temperature and room temperature 2 Reliable and stable measurement thanks to the advanced Infrared Detection System 3 Beep and LCD backlight blink alarm if temperature is more than 100 4 F 38 C 4 Three color backlit LCD digital display screen Green lt 99 1 F 37 3 C Orange 99 3 F 100 2 F 37 4 C 37 9 C red gt 100 4 F 38 C 5 Memorize the last 32 temperature measurements 6 Temperature can be displayed in either Celsius or Fahrenheit 7 Automatic power off 30 secs to conserve energy 8 Longevity use 40 000 reading How To Take A Body Temperature At Body mode default aim at the FOREHEAD or at the right temporal region from a distance of 1 2 2 in press the scan button to get body temperature in 1 second Make sure to remove hair and perspiration from the forehead before scanning Important This thermometer is designed to measure internal body temperature from forehead You ll not get the correct body temperature if attempting to measure over other part of the body e g arm torso Normal Temperatures According To Age Age C F 0 2 years 36 4 38 0 97 5 100 4 3 10 years 36 1 37 8 97 0 100 0 11 65 years 35 9 37 6 96 6 99 7 gt 65 years 35 8 37 5 96
4. bove 140 F in Surface mode THE SCREEN DISPLAYS THE MESSAGE LO When using the Non Contact Infrared Thermometer the message LO can show on the screen In this case the temperature analyzed is under the measuring range selected either less than 89 6 F 32 C in Body Mode or due to other reasons as listed below This message displays for various reasons Please find below a list of the main issues Reasons for LO message display Advice Temperature reading hampered by hair Make sure there is no obstruction or dampness or perspiration prior to taking temperature Temperature hampered by an air draft Make sure there is no air blowing in the area or dramatic change in ambient temperature of use this could affect the infrared reading Temperature readings are too close Pause for 15 seconds minimum between together and the thermometer did not have readings a one minute pause is recommended time to reboot The measuring distance is too far Take measurements at the recommended distance app 1 2 2in 3cm 5cm A easy s me EASY AT HOME MEDICAL LLC http www easyathometesting com X Toll free service 1 855 822 6999 Haden China
5. ometer can take temperature readings below 89 6 F or above 109 2 F but precision is not guaranteed in this situatoin Longevity of the Product The Non Contact Infrared Thermometer is conceived for an intense and professional use Its longevity is guaranteed for 40 000 takings Maintenance of the Product The protective glass over the lens is the most important and fragile part of the thermometer Take care when using storing or cleaning Clean the glass with cotton fabric dampened with a 95 alcohol solution Do not use other batteries than AAA Do not recharge non rechargeable batteries or throw batteries in fire Please dispose of batteries properly Remove the batteries when thermometer is not to be used for a long time Do not expose the thermometer to water or direct sunlight An impact may damage the product Accessories User manual 1 pc AAA alkaline batteries 2pcs Troubleshooting If you have problems while using the thermometer please refer to this guide for help If the problem persists please contact our customer service THE SCREEN DISPLAYS TEMPERATURE LOWER THAN 89 6 F 32 C Check the Mode to see if it s in Surface or Room temperature mode THE SCREEN DISPLAYS THE MESSAGE HI When using the Non Contact Infrared Thermometer the message HI can show on the screen In this case the temperature is above the measurement range selected either above 109 2 F 42 9 C in Body Mode or a
6. on pressing this button At switch on state press MEM button and hold for 4 seconds all data in memory will be deleted Then press MEM button again the display will show CLr Important The surface Temperature differs from the internal body temperature To obtain correct internal body temperature always use BODY mode 6 Recalibration of the thermometer via the F4 MENU The F4 function will recalibrate the thermometer The thermometer is set for reading from the forehead and is properly pre set at the factory Recalibration is needed if you would like to take temperature reading from one of the other reading areas perennial area or upper gum Take your temperature using a conventional thermometer and if you see a difference in the reading recalibrate this the thermometer following the steps as below Steps for recalibration e Press the MODE and c F buttons at the same time for 3 seconds The screen will then displsy F4 e Press Mode to increase 0 1 F C press C F to reduce 0 1 F C Press MEM button to save the setting High Temperature Alarm The factory default alarm is set at 100 4 F 38 C Battery Low Voltage Detection If the battery voltage drops to less than 2 7V the Non Contact Infrared Thermometer will beep four times and display the symbol to remind you to replace the batteries Replace the Batteries When the LCD screen displays Battery the batteries should be replaced Open