Home
PALMER - PPB10
Contents
1. PPB10 User Manual Page 4 COMPONENTS e OUTO OUT OUTS OUT OUTS OUTS OUT4 ouUTrs OUT OUTI T Palmer MALE N ERRANT GROUNO LIFT SWITCHES 11 12 8 oo 01 Line input 02 5 segment meter output level 03 Input gain 04 10 split outputs 05 Headphones volume 06 Headphone output 07 Power LED 08 Fuse and mains connector 09 Power switch 10 Connects electronic ground to chassis ground 11 Ground Lift switches for the outputs 12 Bus connections for linking numerous PPBs 13 Ground Lift for the inputs 14 Parallel line input PALMER PPB10 User Manual Page 5 CURVE PLOTS Jun 15 2009 Mon 11 37 34 RMS CH1 vs GEN FREQ e UI Frequency amp Phase Response Line Input to Output Source OdBu 600 Ohms Load 200k Ohms dBu 8 Tes 7 6 6 5 5 4 4 3 3 Ze 2 1 al OF 0 Jun 15 2009 Mon 11 41 47 vs GEN FREQ Hz O O O O O O O O O Ha e N U UA A N O O Total Harmonic Distortion THD Line Input to Output Source 0dBu 600 Ohms Output Level 6dBu PALMER PPB10 User Manual Page 6
2. 0k Ohm Nomineller Eingangspegel Odbu maximal 20dBu Maximale Verst rkung zum Ausgang 25dB Ausg nge 10 trafosymmetrische Ausg nge XLR m mit GND LIFT Schalter Nomineller Ausgangspegel 4dBu bei 600 Ohm Last und OdB LED Anzeige Nominelle Ausgangsimpedanz 300 Ohm Kopfh rerausgang 6 3mm Stereoklinke Tip und Ring mono verschaltet F r Kopfh rer von 8 bis 200 Ohm geeignet Lautst rke kontinuierlich einstellbar 5 stufige LED Kette 12dB 6dB OdB 3dB 6dB zur berwachung des Ausgangspegels BUS Ein und Ausgang ber Monoklinke zur Erweiterung der Anzahl der Ausg nge Stromversorgung 230 240VAC andere auf Anfrage max Leistungsaufnahme 10 Watt Mechanisch 19 Stahlblechgehause 1 HE ca 205mm tief GEWICHT 4Kg PALMER PPB10 User Manual Page 2 KOMPONENTEN POWER as GROUND LIFT SWITCHES _ i LIN EIN Po ti 11 01 Lineeingang 02 Pegelanzeige Ausgangspegel 03 Eingangspegelsteller 04 10 Splitausgange 05 Kopfh rerlautst rke 06 Kopfh rerausgang 07 Power LED 08 Netzstecker mit Sicherung 09 Netzschalter 10 Verbindet trennt die elektronische Erde mit von der Geh userde 11 Ground Lift Schalter f r die Ausg nge 12 Bus verbindung um mehrere PPB10 oder PPB20 zu kaskadieren 13 Ground Lift f r den Eingang 14 Paralleler Lineeingang PALMER PPB10 User Manual Page 3 INTRODUCTION The PPB10 is a special kind of audio splitter in that it splits on
3. English German PALMER PPB10 PRESS PATCH BOX 10 Channel splitter 10 Kanal Audiosignalverteiler USER MANUAL BEDIENUNGSANLEITUNG AUFGABE Eine Press Patch Box ist ein spezieller Audiosignalverteiler der ein vorhandenes Ausgangssignal auf eine Vielzahl von Ausg ngen verteilt Einen typischen Anwendungsfall stellt eine Pressekonferenz dar wo Informationen durch einen Sprecher an viele Journalis ten gerichtet werden Damit nun nicht jeder der Medienvertreter sein individuelles Mikrofon aufbauen mu und es zu einem Geran gel um die besten Pl tze kommt kann das Signal eines einzigen Mikrofons ber die Palmer Press Patch Box auf eine Vielzahl von Ausg ngen entsprechend verteilt werden AUSSTATTUNG Die PPB10 besitzt einen trafosymmetrischen Eingang f r Linesignale Mechanisch ist er als XLR f Buchse sowohl auf der Frontseite wie auch auf der R ckseite vorhanden Eine parallele Benutzung wird nicht empfohlen Neben der r ckw rtigen Buchse befindet sich ein Ground Lift Schalter der den Pin 1 beider XLR Buchsen von der Masse freischaltet ber den Pegelsteller rechts neben der frontseitigen Eingangsbuchse kann die Verst rkung von maximaler D mpfung auf 25dB eingestellt werden Eine 5 teilige LED Kette gibt Auskunft ber die H he des Ausgangssignals Bei OdB Anzeige hat das Ausgangssignal einen Pegel von 6dBu unbelastet bei Abschluss mit 600 Ohm sinkt der Pegel auf 4dBu Die PPB 10 verf gt ber 10 symmetrische Aus
4. LY The PPB10 is powered by an internal 230 Volt power supply Power connector fuse compartment and power switch can be found on the rear of the device A red LED on the front indicates that the device is turned on A horizontally mounted ground switch is allo cated between the power switch and the individual ground lift switches on the rear The switch connects disconnects the electronic ground from the housing of the unit A disconnection makes sense to avoid ground loop humming when the unit is fitted into a 19 rack together with other mains powered devices The yellow green PE grounding connector however remains connected according to the regulations SPECIFICATIONS Inputs XLR f parallel connectors on the front and rear transformer balanced ground lift switch Nominal impedance 10kOhms Nominal input level OdBu max 20dBu Max amplification to the outputs 25dB Outputs 10 transformer balanced outputs XLR m with ground lift switch Nominal output level 4dBu at 6000hms load and OdB LED meter Nominal output impedance 3000hms Headphone output 6 3mm 1 4 stereo jack tip and ring connected together Suitable for headphones from 8 to 2000hms volume steplessly variable 5 segment LED chain 12dB 6dB OdB 3dB 6dB To monitor the output level Bus in and out via mono jack to connect several units Power supply 230 240VAC max power consumption 10Watts Mechanical 19 1U Steel housing 205mm deep Weight 4Kg PALMER
5. e incoming signal up to twenty outputs as opposed to the usual three This splitter is especially intended for press conferences in which a speaker addresses a number of journalists Instead of each journalist having to place his or her own microphone in front of the speaker the PPB10 splits up the signal of one microphone up to twenty outputs FUNCTION The PPB10 is comes with a transformer balanced input for line signals Mechanically the input is equipped with Neutrik XLR f sockets on the front as well as on the rear of the device We do not advise a simultaneous use of both inputs A ground lift switch is located next to the XLR input on the rear this switch disconnects the pin 1 of both input XLRs from ground You can adjust the input gain with the gain pot next to the front XLR input the gain ranges from to 25dB The 5 segement LED meter helps you monitor the output level When this meter indicates OdB the output level reads 6dBu without a load connected and 4dBu with a load of 6000hms The PPB10 offers 10 balanced outputs which are located on the front of the device in form of Neutrik XLR m sockets All 10 outputs are galvanically isolated by the use of transformers To avoid interferences between the individual channels 5 low ohmic driver circuits are used to drive 5 transformers each of which split up the input signal to two outputs The output pairs coming from each transformer are decoupled from each other by the use of resistors I
6. g nge die mechanisch als XLR m Buchsen auf der Frontseite angeordnet sind Alle 10 Ausg nge sind galvanisch durch bertrager isoliert Um eine Beeinflussung der Ausg nge untereinander auszuschlie en wird f r jeweils ein benachbartes Paar eine sehr niederohmige Treiberschaltung eingesetzt die einen Ausgangs bertrager mit zwei facher Splitwicklung speist Gegeneinander wird ein solches Ausgangspaar mit Widerst nden entkoppelt Im Kurzschlussfall eines Ausgangs wird daher allenfalls ein Nachbarkanal um ca 3dB ged mpft alle brigen Ausg nge bleiben absolut unbeeinflusst Die Ausg nge k nnen individuell ber einen GND Lift Schalter der sich auf der R ckseite befindet erdfrei geschaltet werden PPB10 KASKADIEREN Um die Anzahl von Ausgangskan len zu erweitern k nnen mehrere PPB10 miteinander kombiniert werden Dazu dienen die r ck seitigen BUS IN BUS OUT Buchsen Vom Master also dem Ger t das das Eingangssignal liefert wird die BUS OUT Buchse mit der BUS IN BUCHSE des zweiten Ger tes verbunden An der BUS Out Buchse dieses Ger tes k nnen Sie dann das n chste Ger t anschlie en Benutzen Sie als Verbindungskabel ein abgeschirmtes Mono Klinkenkabel Die BUS OUT Buchse eines Ger tes kann auch als zus tzlicher unsymmetrischer Ausgang genutzt werden Bei OdB Anzeige betr gt die Ausgangsspannung OdBu KOPFH RER Zur akustischen berwachung des Eingangssignals ist ein Anschluss f r Kopfh rer vorhanden Die 6 3mm Stereobuch
7. n case of a short circuit on an output only one other channel will be affected in that it is dampened by 3dB All other channels remain completely unaffected Each output has its individual ground lift switch on the rear of the device CASCADING THE PPB10 To increase the number of output channels you can cascade numerous PPB10 For this application the unit has been equipped with BUS IN BUS OUT connectors on the rear Simply connect the BUS OUT of the first device which is connected to the source signal to the BUS IN of the second device The BUS OUT of the second device can then be connected to the BUS IN of a third device and so on Use a shielded cable with mono jacks to make these connections The BUS OUT can also be used as an 11th split output Here the output reads OdBu when the meter on the front shows OdB HEADPHONES To acoustically monitor the input signal you can connect a pair of headphones to the PPB20 The 1 4 TRS jack socket on the front is connected in such a way that the mono input signal can be heard equally on both sides of the headphones the tip and ring of the jack socket are connected together Should you use this output for other purposes make sure not to use a mono jack connector since the shaft of the connector will short a part of the output voltage All headphones with impedances from 8 to 200 Ohms can be connected The headphone volume can be adjusted via the volume pot next to the headphone connector POWER SUPP
8. se auf der Frontseite ist so verschaltet dass sich ein Monosignal L R auf beiden Kapseln ergibt Tip und Ring der Klinkenbuchse sind mitein ander verschaltet Falls Sie den Kopfh rerausgang anderweitig belegen achten Sie unbedingt darauf dass kein Monoklinken stecker benutzt wird da in diesem Fall ber den Schaft des Steckers ein Teil der Ausgangsspannung kurzgeschlossen w rde Alle Kopfh rer mit Impedanzen von 8 bis 200 Ohm k nnen angeschlossen werden Die Lautst rke l sst sich ber das nebenan befind liche Potentiometer in weiten Grenzen einstellen STROMVERSORGUNG Die PPB 10 wird Uber ein eingebautes Netzteil aus dem 230 240V Netz versorgt Eine IEC Netzbuchse mit integriertem Sicherung shalter ist auf der R ckseite des Geh uses vorhanden Daneben befindet sich der Netzschalter Eine rote LED auf der Frontseite zeigt an ob das Ger t eingeschaltet ist Zwischen Netzschalter und den individuellen Ground Lift Schaltern der Kan le befindet sich ein weiterer horizontal angeordneter Er dungsschalter Dieser Schalter verbindet trennt die Elektronikmasse vom Geh use Das Trennen der Elektronikmasse vom Geh use beseitigt z B in 19 Ger teschr nken oft gef rchtete Masseschleifen Der gelb gr ne Schutzleiter PE ist jedoch vorschriftsm ig immer mit dem Geh use verbunden TECHNISCHE DATEN Eing nge Trafosymmetrisch f r Linepegel XLR f Parallelbuchsen auf Front und R ckseite mit Ground Lift Schalter Nominelle Impedanz 1
Download Pdf Manuals
Related Search
Related Contents
Norge 1200 GT 8V - Utilisation / Uso - 09/2010 LevelOne 1000BASE-SX MMF SC PCI Network Card D-Link DWA-120 Adit 3000 and MSR GUI Reference Manual UNE AGENCE D`ARCHITECTURE FORTEMENT none 7269004-P62HO Instructions / Assembly MODE D`EMPLOI WEB-TDFC Verhandlungsleiter Ulrich Marten: ........................................................ Copyright © All rights reserved.