1. The unit has built in power protection that works automatically when needed When it works USB communication halts and the only way to restart the unit properly is to remove all power sources USB patch cables and power adapter wait a few seconds apply power sources and start again Symptom Causes Solutions In Auto Scan m keyboard and mouse are not operable Too many keyboards or mouse drivers installed Improper device W driver Device consumes too much power Device consumes too much power instantaneously m Improper device initialization 16 Press any front button to select a computer then use the keyboard and mouse Remove ALL unnecessary keyboards and mouse drivers Re install device driver The device should be self powered add a power adapter to the device If the device does not provide power jack add a power adapter with DC9 12V of less than 1A current rating to the unit Be sure the USB cable is well seated to ensure communication Remove all power sources to the W When the unit works under Self power i e no power supply m added it supports max of 100mA as per USB spec Device initialization takes too much time All PCs are off or only one PC is turned on Scan mode works for power on computers only Some DVI video cards do not respond to the signal switch simultaneously 17 Claxan Switch unit by unplugging all USB A B cables and
2. a CCD camera printer or scanner it is required to shut down the driver of the computer before switching to another computer Because port switching is equivalent to unplugging the USB cable from one computer and plugging it to another one some USB drivers check attached USB peripherals all the time and do not accept plug n play function Claxan Switch Console Connection Before installation make sure all devices and computers to be connected to the unit have been turned off Plug a monitor to the Console s DVI port plug a USB keyboard and a USB mouse to any two of the Console s USB ports as shown below Claxan Switch Computers Connection Use a male to male cable to connect from a computer s DVI port to the unit s DVI port of PC side Use a USB A B Cable to connect from the unit s USB port B connector square connector to the USB port on the corresponding computer A connector flat connector as shown below male to male HOBIS for DYI One USB patch cable for both keyboard and mouse male to male HDB15 for DVI One USB patch cable for both keyboard and mouse Audio cable speaker MIC Now you can turn on all devices and computers 6 Claxan Switch Ch ee Operations Front Panel 1 On line LED amp Selected LED When the LED turns green the connected computer is powered on When a computer is selected its corresponding red LED illuminates 2 Pushbuttons Each computer has a button asso
3. Claxan Switch CL KVM DAAG 112 w Audio CL KVM DAAG 114 w Audio Manual value for money High Video resolution Auto scan for easy monitoring Hot plug and play Audible buzzer for switching confirmation L A X A N Package Contents CL KVM DAAG 112 w Audio 2 Port CL KVM DAAG 1 12 User s manual Rubber foot pad CL KVM DAAG 114 w Audio 4 Port CL KVM DAAG 1 14 User s manual Rubber foot pad PP5 GG0800 010 Printed in Taiwan Table of Content Introduction 1 Overview AEE 1 Features enne 2 System Requirements 3 Console side 3 Computer 3 Installations 4 PC BIOS 4 Console Connection 5 Computers Connection 6 B 7 Front 7 Rack Mount Kit 14 15 15 B Troubleshooting 16 Pm O Please read this manual thoroughly and follow the Installation p
4. Press Num Lock Press Num Lock then release shift Press 1 Selects the computer at port 1 Hold Left Shift Press Num Lock Press Num Lock then release shift Press 2 Selects the computer at port 2 Do not use the keypad at the right of the keyboard 13 Claxan Switch F Rack Mount Kit The figure below shows how to attach optional mounting brackets and cable support RMK04 to the CL KVM DAAG 114 for standard 19 inch rack cabinet To the rack cabinet back post Claxan Switch Se TERR Appendices Specifications Console Port 1 1 Computer Port 2 4 Front panel push button 1 4 FUNC button N A 1 Hot plug and play Yes Yes Automatic scan interval 3 8 15 30 seconds 3 8 15 30 seconds Cable length Max 3M 10ft for USB 3M 10ft for USB Computer ON LINE LED 2 4 Computer selected LED 2 4 KB USB B x2 USB B x4 Computer M5 Monitor DVI female x 2 DVI female x 4 Interface Audio Jack 2 4 Speaker MIC e USB Ax 4 USB Ax 4 Gorele Monitor DVI female x 1 DVI female x 1 Interface Audio Jack 1 1 Speaker MIC Hot Key Yes Resolution 1920 x 1200 DDC2B support Yes 44 x 160 x 100 mm 44 x 220 x 130 mm HE 17x63x39 n 17x87x5 1 in size Compact Compact 15 Claxan Switch Troubleshooting Ensure that all cables are well seated Label the cable for each computer to avoid confusion when connected to the unit
5. or Press pushbutton 3 one or two times for adjusting the output current of selected port with one beep normal or two beeps enhance respectively or a Press pushbutton 4 one two three or four times for adjusting the output emphasis of selected port with one beep no pre emphasis two beeps low pre emphasis three beeps medium pre emphasis or four beeps high pre emphasis Step 3 Once the setting is finished press FUNC button one time to exit the setting Claxan Switch Hotkey Commands The Hot key command is a short keyboard sequence to select a computer to activate computer scan etc KVM Switch interprets keystrokes for hot keys all the time A hot key sequence starts with two left Ctrl keystrokes in 0 2 seconds followed by one or two more keystrokes A built in buzzer generates a high pitch beep for correct hot key command otherwise one low pitch beep for error and the bad key sequence will not be forwarded to the selected computer NOTE Press and hold Left Shift then press Num Lock twice then release Shift and then press left Ctrl once the user can enable disable the hotkey function 1 2 3 4 5 6 7 8 9 0 To select a computer Press Left Ctrl Press Left Ctrl Press 1 Selects the computer at port 1 Press Left Ctrl Press Left Ctrl Press 2 Selects the computer at port 2 To start Auto Scan automatically scan power on computers one by one at a fixed interval Press Left C
6. B peripherals KB MS 2 USB Devices Unique Tracking System enable the USB amp Audio devices to operate independently Front panel push buttons for easy computer selection Rear panel FUNC button for easily adjusting the video signal strength for CL KVM DAAG 114 only No drivers needed for keyboard and mouse operation Support keyboard and mouse plug n play Buzzer sound for computer switching confirmation Activate Auto Scan by front buttons pressing Selectable Scan Time interval Support the DVI monitor Support Windows and Mac host systems No software required Claxan Switch futu E System Requirements Console side e One DVI monitor e One USB keyboard e One USB mouse Computer side Each USB enabled computer must be connected to the unit by e One DVI cable for monitor as shown below gt Nw One USB A B cable with Type A and Type B plug for USB devices Id Or one DVI 2 to 2 cable for monitor USB devices as shown below Claxan Switch Soe es Installation PC BIOS Notice The following BIOS setup changes are necessary for PC users and not necessary for Mac users 1 In STANDARD CMOS set HALT ON ERROR to ALL BUT KEYBOARD 2 In PNP AND PCI SETUP set PNP OS INSTALLED to YES and set USB IRQ to ENABLED Note The CL KVM DAAG 112 CL KVM DAAG 114 is applicable for USB keyboard and mouse switching from one computer to the other If you plan to share other peripherals such as
7. ciated with it on the front panel for selection Auto Scan Auto Scan automatically scan through computers one by one in a fixed interval see Scan Time below To activate Auto Scan press down front panel push buttons 3 and 4 simultaneously The port LED flashes during Auto Scan Auto Scan is effective for powered on computers only To exit the Auto Scan mode just tap any one of the pushbuttons CL KVM DAAG 114 only Note keyboard and mouse are not operable during Auto Scan Claxan Switch Scan Time It sets the scan interval for Auto Scan The Scan Time options are 3 8 15 and 30 seconds To change the Scan Time interval press both front panel buttons 1 and 2 simultaneously The unit beep 1 2 3 or 4 times for Scan Time of 3 8 15 or 30 seconds respectively CL KVM DAAG 114 only Note Scan Time is automatically set to the default of 3 seconds when the unit loses power FUNC Button CL KVM DAAG 114 only the video To adjust the optimal video signal strength corresponding to the length or quality of DVI cable the user can press FUNC button combining with the other pushbuttons Step 1 Press FUNC button three times the LED of POWER will flash one time per second Step 2 B Press pushbutton 1 one or two times for adjusting the 8 Claxan Switch equalization of selected port input video strength with one beep normal or two beeps enhance respectively
8. on please contact your direct vendor All the brand names and registered trademarks are the property of their respective owners 19
9. owed with the selected computer by pressing the following hotkey Press Left Cirl Press Left Ctrl Press A USB Port Rule There are two options for USB Port Rule ON and OFF When set to ON USB Port selection follows computer selection When set to OFF USB Port selection stops to follow computer selection 1 USB 1 pressing the hotkey below to turn ON OFF the USB Port Rule Press Left Ctrl Press Left Ctrl Press F7 2 USB 2 pressing the hotkey below to turn ON OFF the USB Port Rule Press Left Ctrl Press Left Ctrl Press F8 CL KVM DAAG 114 only Enforce the USB followed with the selected computer by pressing the following hotkey Press Left Cirl Press Left Cirl PressU NOTE Please make sure that USB device linking procedure has accomplished before switching to the next computer 12 Claxan Switch Alternative Hotkey Commands In addition to the Left Ctrl Left Ctrl hotkeys there are two other hotkey sequences available 1 Users may Press Scroll Lock twice instead For example To select a computer Press Scroll Lock Press Scroll Lock Press 1 Selects the computer at port 1 Press Scroll Lock Press Scroll Lock Press 2 Selects the computer at port 2 Do not use the keypad at the right of the keyboard 2 For those keyboards didn t have or support Scroll Lock please press and HOLD the Left Shift and then press Num Lock twice instead For example To select a computer Hold Left Shift
10. rocedures to prevent any damage to the Unit or any connecting device FC RoHS Claxan Switch Introduction Overview The CL KVM DAAG 112 and CL KVM DAAG 114 fully compatible with USB specification are the combination of USB KVM keyboard Video mouse switch and USB peripherals sharing device With the 2 4 Port USB KVM switch you can easily operate up to 4 PCs G3 G4 Macs or iMacs respectively from 1 USB keyboard 1 USB mouse and 1 DVI monitor saving you space time equipment and money The peripheral sharing function enables you to share more USB peripherals among all computers The FUNC button for adjusting the video signal strength The audio function enable users to switch among 2 4 media sources and enjoy the output on one display and one set of speakers Installation is as easy as connecting USB A B cables to computers and to the unit Computer selecting is as easy as front panel button pressing The built in USB hub ensures smooth switching from one computer to the other The CL KVM DAAG 112 CL KVM DAAG 114 provides the easiest way to manage multiple computers with USB interface and share USB peripherals among computers No more tangled cables and messy working environment let the CL KVM DAAG 112 CL KVM DAAG 114 do the computer switching for you Claxan Switch Features Support USB Console Support DVI Single Link with the resolution up to 1920 x 1200 2 4 computers share up to 4 different US
11. the power adapter then start all over again Select the computer by pushbutton restart the computer and try again Wait at least 5 seconds before computer switching to ensure proper USB communication Turn off device driver not keyboard nor mouse before computer switching Turn computers on Make sure that you have plugged a monitor to the Console s DVI port before plugging unplugging the PC s DVI connector s Wait for few seconds or Use the FUNC button to adjust the video signal strength settings of the unit Claxan Switch video signal strength corresponding to the length or quality or DVI cable the user can press FUNC button combing 18 with the other pushbuttons Claxan Switch Limited Warranty IN NO EVENT SHALL THE DIRECT VENDOR S LIABILITY FOR DIRECT OR INDIRECT SPECIAL INCIDENTIAL OR CONSEQUENTIAL DAMAGES LOSS OF PROFIT LOSS OF BUSINESS OR FINANCIAL LOSS WHICH MAY BE CAUSED BY THE USE OF THE PRODUCT EXCEEDS THE PRICE PAID FOR THE PRODUCT The direct vendor makes no warranty or representation expressed or implied with respect to the contents or use of this documentation and especially disclaims its quality performance merchantability or fitness for any particular purpose The direct vendor also reserves the right to revise or update the product or documentation without obligation to notify any user or organization of such revisions or updates For further informati
12. trl Press Left Ctrl Press F1 To abort the Auto Scan mode press the eft Ctrl key twice When Auto Scan detects any keyboard or mouse activity it 10 Claxan Switch suspends the scanning till the activity stops it then resumes with the next computer in sequence The length of the Auto Scan interval Scan Rate is adjustable see below Manual Scan enables you to manually switch back and forth between power on computers Press Left Ctrl Press Left Ctrl Press F2 Press or to select the previous or the next computer in sequence And press any other key to abort the Manual Scan To adjust Scan Rate this sets the duration before switching to the next computer in Auto Scan Press Left Ctrl Press Left Ctrl Press The KVM Switch generates 1 to 4 beeps indicating scan interval of 3 8 15 and 30 seconds respectively Audio Stick An optional multimedia module can be LINKed to the back of each KVM switch for selecting microphone and stereo speaker signals There are two options for Audio Stick ON and OFF When set to ON audio selection follows computer selection When set to OFF audio selection stops to follow computer selection It is useful if you want to listen to a particular computer s audio signal while operating other computers Press Left Ctrl Press Left Ctrl F5 The KVM switch beeps once or twice corresponding to ON and OFF respectively 11 Claxan Switch Enforce the audio foll

Download Pdf Manuals

image

Related Search

Untitled untitled boxing game codes untitled document untitled goose game untitled spreadsheet untitled notepad untitled paint untitled app untitled presentation untitled entertainment untitled attack on titan codes untitled at 3 freeman alley untitled 1 untitled boxing codes untitled tag game codes untitled stream untitled ui untitled 2 untitled boxing game wiki untitled paint 3d untitled diagram untitled music app untitled boxing game tier list untitled form untitled design untitled music

Related Contents

Directive pour l`application par projection thermique  BD ペンジェクター2  INDICADORES 48 x 48 mm y 48 x 96 mm  pLDPRO - Carel  7107 User Manual - Sealevel Systems, Inc  CALL! - Henry Schein  "service manual"  12 Volt 30 Amp Digital Solar Charge Controller  CHANT (Annales) - Confédération Musicale de France  Vinotemp VT-SC-1 User's Manual  