Magnetek Material Handling IMPULSE •LINK 4.1 Basic

image

Contents

1. Magnetek Material Handling IMPULSE gt LINK 4 1 Basic Instruction Manual Electromotive February 2006 Part Number 140 10350 Copyright 2006 Magnetek Material Handling 2005 MAGNETEK MATERIAL HANDLING All rights reserved This notice applies to all copyrighted materials included with this product including but not limited to this manual and software embodied within the product This manual is intended for the sole use of the persons to whom it is provided and any unauthorized distribution of the manual or dispersal of its contents is strictly forbidden This manual may not be reproduced in whole or in part by any means whatsoever without the expressed written permission of MAGNETEK IMPULSEsLINK 4 1 Basic Software is Copyrighted by Magnetek All rights reserved Table of Contents Warning Caution and Notice Chapter 1 Introduction Overview System Requirements Chapter 2 Installation Software Installation Connecting to your PC Creating Communication Profiles Using the Wizard Getting Started Chapter 3 Navigation Chapter 4 Parameter Maintenance Read From VFD Write To VFD Modifying Parameters Parameter File Comparison Security Password Protection Chapter 5 Monitoring Monitor Fault Reset Chapter 6 Additional Menu Features Print Preview amp Print Parameter File Conversion Viewing Parameters Keypad Simulator Copy amp Paste Chapter 7 Troubleshooting Drive Fault References
2. Emulates the keypad and allows for navigating the keypad menu remotely Show Error Log shows the status of IMPULSE LINK 4 1 Basic IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 9 Window Allows for easy parameter window organization when in Window L multiple window mode The functions in the Window menu such as Cascade Tile Horizontally and Vertically Minimize All and Close applications Tile Horizontal Tile Vertical i Cascade All function just as they do in other Microsoft Windows based Minimize All Close All v 1 ParFile1 Help Users Manual Displays the User Manual Acrobat Reader must 12 User Manual be installed IMPULSE LINK Help Provides information on communication 2 Impulse Link Help profile settings and troubleshooting complete Index of VFD fault codes and a Search function Electromotive on the Web provides a link to the Magnetek ad Electro motive On the Web Material Handling website Check for Updates provides a link to the download software Check for Updates page of the website that offers updates About Displays the version number of this Electromotive About Systems product copyright and legal notices IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 10 Chapter 4 Parameter Maintenance IMPULSEeLINK 4 1 Basic software provides flexibility in programming uploading downloading and saving parameters With full parameter descr
3. 1 CD containing IMPULSEeLink 4 1 Basic Software 2 Cable for IMPULSE G VG Series 2 3 Cable for IMPULSE P3 Series 2 or IMPULSE G VG Series 3 drives 4 USB to serial converter SYSTEM REQUIREMENTS Supported Drives IMPULSEeLINK 4 1 Basic supports the IMPULSEsP3 Series 2 IMPULSE G VG Series 2 and Series 3 drives Supported Communication IMPULSEeLink 4 1 Basic supports the following types of communication Serial RS232 RS485 7 Availability Availability IMPULSE VG Series 2 140 10261 IMPULSE VG Series 3 IMPULSE P3 Series 2 Modbus RTU Modbus RTU 1 USB to Serial converters are available if an RS232 serial port is not found on your PC 2 A USB to RS485 converter an RS232 to RS485 converter or an RS485 card is required for your PC PC Requirements 1 Pentium class or equivalent 500M Hz processor or better 2 256 MB RAM or better 3 Minimum of 100 MB free hard disk space available 4 Windows 98 SE operating system or better IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 3 Chapter 2 Installation SOFTWARE INSTALLATION The IMPULSE LINK 4 1 Basic comes with a CD containing the IMPULSE LINK 4 1 Basic Software and Adobe Acrobat Reader for this technical manual e Torun the IMPULSE LINK 4 1 Basic Setup put the IMPULSE LINK 4 1 Basic CD into your CD drive Run setup exe from the CD if it does not start automatically Loading Plugins e Select the default choices during installat
4. Communice Mp aee various communication and application errors that may occur 8 IP Address Commur i Error Reference IMPULSE Link 4 1 has adopted anew naming convention in dealing with IE Part Camine Errors have been placed in the following categories 3 7 Max Resends Comr 7 Parity Communicatic CE Communication Error 2 Part Communication This includes problems opening ports sending messages and temmeouts while o 2 Protocol Communic waiting Jor messages p slave Address Cam DLE Download Error 32 Timeout Communice In addition to communication errors there are additional errors that could cause Troubleshooting 0 Drive Fault Reference f BIRCRTORE RO a GHGs Series 2 IF Initialization Fault e Ge VG Series 3 IMPULSE Link 4 1 runs through a sel check wren if begins These faults Af Error Reference cause ihe application to fai to start CE Communication E OE Operator Error amp DLE Download Erro This includes errors due to the user attempting to do something the program x Q amp IF Initialization Faulte does not support such as attempting to load an unsupported file format amp amp OE Operator Errore OLE Online Edit Error SOL OLE Delve EH EN This wicludes various errors that may occur while online with a VED usually Hes during editing IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 19 By clicking on the type of error you will be provided
5. Unlocked A108 Enter Password 2 Model 2003 G Series 3 Flash ID 8001 3 Copy amp Paste The copy amp paste function works just like a Microsoft Windows application You can highlight multiple rows and or columns using either the shift key or your mouse and then right click to either copy or print that highlighted area If you selected copy when the area is highlighted you can then open another Windows application and paste Locked IMPULSE Link 4 1 Basic ParF ile1 File Settings VFO Tools Window Help ju LE SA rfe Default Profile bd A 4129 Properties Read Write Help Sel view Group F Options hull Description Setting Unit Cho VF OLY Parameter AI 14 Input Sel F201 Zu O 3chindvidual x A r30 Diinpt 7 Binary lao Ch Select 2 Output Freq J AO Chi Gain 100 0 AO Ch Select 3 Dutput Current AO Ch2 Gain Model 2003 G Series 3 Flash ID 8001 3 IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 1 Chapter 7 Troubleshooting Impulse Link 4 1 Hel In the Troubleshooting section of i the IMPULSE LINK 4 1 Basic Help Menu you can select either Drive Fault References or Error References The Drive Fault References provide the fault code description and corrective action for all of the IMPULSE G VG Series 2 and Series 3 faults and IMPULSE P3
6. Cm H Pts IT Lr aL os qei be UP Fik oum gm a Pn aru ie hiram Ri Tar e lw Pim 5 eel tml al cum Um oam fn Lies aia L dul Fi Lise Dedi re mur lia oun fhe oa pel mm dom oae rung pb gom lki Vu oae 8 La d edu gel ilm olli a L ug Fh Lies Ded L E i ihe mu amp mde cip gm n m Pines Lun Em en FE BH Mii atl zm hu oam Em liem ba it Visi T ee Iz WR Lee Dui Bot wem Pee Z Sr Lie Dua ay pd zum bom m ama mu alim LEF Mui ien RAS Luigi EL Like onem ri Mii Limi Coal EIE imum bam bp bum stu a 18 ieee Pee I FR Lies i ASI iim om m Lime Lond M i amm h 3 mer ram mu oe Libi eee 2 Fin Lem Duis Le lerr hae Eir Lim Loin Ln iem Faces Er Lem Dung i bhir ee Sr lie i La V mr og am doom oui ESO amm bu gm i rmm 5 Print Name Allows the user to select from any printer installed on his her system The user s default printer is initially selected Print Mode Allows the user to choose the printing style o Compact mode 1 2 pages provides parameter names and setting values o Detailed mode provides parameters descriptions setting values units as well modified information o As shown prints all of the information as shown on the screen OK Button Prints the active parameter set to the selected printer in the chosen format Application Cancel Closes this dialog box without printing Changes to Customer Name Application and Job Number are not saved SI PAUL lt Text placed in the C
7. Home paman inden Search IH Weinert 16 the IMPULSE ink i Danimunicshan Freshna 3 ly Troubleshooting i P d rom Feul Eofenmmoe i G Eire Rolina Pant Gpetons Welcome to the IMPULSE Link 4 1 Help Series 2 faults Therefore you will not need to consult your technical manual when you have IMPULSE LINK 4 1 Basic running The Error References Are communication errors that could occur while running IMPULSE LINK 4 Basic System V a Tir T p a TT Leo 154r IT Drive Faults References IMPULSE LINK 4 1 Basic offers built in Help screens for the drive faults and or alarms The Help screens provide advanced diagnostics allowing you to troubleshoot your drive from your PC When you click on the fault the help screen provides the fault code fault name description and the corrective action Bridge 1 Drive Monitor Bridge Drive a Series 3 230 3 20 Flash ID BODL 3 Model 2003 Input Terminal OG0000000 Output Terminal 10000000 15 00 0 00 Frequency Reference Output Frequency Output Current Output Voltage i Bus Voltage 316 Toraue Reference 96 Output Speed Monkoring Faulted Control Method DWF Control zi EFT Ext Fault 7 IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 18 Or you can simply go to the Help Icon and go to the Drive Fault References for a complete list of IMPULSEsP3 Seri
8. Ted Eid HRD Fmibm Eni a Li Fop am s hia Lae Mrd c I aibe Pte AIEO bar P s Em hat Mayet Hele Dx EA Low Pewee bim iia i Hi i feline piy peA Lim Fr Pm iir a Bird edie Piper be r F E are NOT biski MEN Ea Casar ek Be i bisigh dui Da Spm l Pipi i Oca i zl Preferences louem Lek 4 T Acces Leys ADVANCED dreareri Leva Setup Parna F r Lisername Bassvord Erker Curent Password Wew senama CO ces a Neve Leana Hew P amp tswond choose a New Password IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 13 Chapter 5 Monitor Function MONITOR There is a Monitor function in the Tools drop down which displays a select number of monitor parameters U parameters that are continually updated Bridge Drive ae Series 3 aft Pleh ID Control Method 2 05 bunk Tera uinut Torte XE Frequency Reference 15 00 Output Frequency 15 01 Output Current 0 0 Output Voltage 1185 Bus Voltage 7156 Torque Reference O 2 Output Speed Miriga Aree Fera Hz Hz Amps VAL WORE 2 Hz ail FAULT RESET In the event of a fault condition you will see the fault icon on the Monitor window as shown here You can reset a fault in the Monitor window as long as the drive doesn t have a Run command and the fault condition no longer exists Once you click on the fault reset icon a warning message will prompt you to accept that you acknowledge the warning When resett
9. specific parameter i e Changing this parameter from the drive keypad would not be allowed with the current access level Over Maximum Under Minimum A parameter with red text implies that its value is either greater than its maximum value or less than its minimum An invalid value in the FIF file could result in this error MODIFYING PARAMETERS By double clicking on the row of the parameter you would like to edit the setting column will appear as a drop down box a text box or a visual programming window 1 Drop down list box of parameter setting choices List box F Mat User O Mult Step 1 Multi 5tep Ret 3 z Multi Step Ret 4 3 Multi Step Het 5 d Speed Hold 2 Be Accel Command B Upper Lrt 1 AO Upper Lmt 2 AO This will appear for list parameters Simply select the value from the list and ENTER to accept the change ESC to cancel the change 2 Text box for entering a parameter value Text box This will appear for numerical parameters Simply type in the value of the parameter in the base displayed and ENTER to accept the change ESC to cancel the change 3 Visual Programming Window click once on the visual programming icon External Fault Response Selection External Faut Selection Detection tethod Extenal Faut Action Sething Result HZ During Run Stop ton Past Stop IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 12 This Visual Programming Window
10. the error code with description and correction action Impulse Link 4 1 Help Seles Hide Back Home Frit Options MagnetekMH Home Site Map Contents Index Search 2 CE00 Part Already Ope CEUDB Port Could Not Og CE100 Device Not Fauni s GT CE102 Unknown Device Communication Error Reference CE108 Timed Out CE108 Timed Out Resei CE110 Connection Requ Device Not Found E111 Baudrate Settings Fault Code Fault or Indicator Mame Description Corrective Action A E115 con Pgs b T CE114 Unknown Comm CE100 Device Not Found There was not a valid l o A to the loop back to ettings CE203 Could Not Open F Device Not Seepepse t9 Hp dee message B OB bases Siete requested The target device is either not CE204 Unknown Host rou connected not connected properly not powered up 2 CE205 Unable Ta Conne 3 Ensure the target device is powered up or an unknown device CE206 Host Could Not Bi connected properly CES3DU Protocol Driver Er pci ibis CE3I3 Protocol Error hac sini 2 S A DLE Download Errors Series or P3 Series 2 IF Initialization Faults Dive OE Operator Errors OLE Online Edit Errors li COMMUNICATION PROFILE TEST The Communication Profile Test Utility provides a loop back test to the drive to determine the status of communication This function is found in the Tools Profile af Shop Crane bridge drop down menu p W u gt El Communic
11. A HE HM Lai 333 Lim Farms 1l Um Lir 4a ie e Be ee Dad AED Lee Pa i l Vale lupa BS ee i Le La AUI be Pom ie O Ha Live Lp EIU o H ED Phi Lee Dili ARLI Lue Fmum E Pia Lim onda oe Bi Lee Cole SERIES Lines Piim l Me Le Ei BSG A le Les Ew 52411 Le Famam Vin Lie se M l Ta zZEi4 Les Pera H Ha Lin Zaia BITE e HAET He Le Sol Ai Le Pam H Ha Lin Zia Ri44 04H Falha Cali dN de Fena P Ha Lin noa Bis eH F lbn Di eet Lem Faan T Faih Lis Bd EHCET Palin Los AHi bn Pam H Ha ihn lua BL e hiin LEES AHi Lin aram PB Enim 4a BI HE Bb R3 ai iem For I Hai khe Shera Bid CHEE Ha ihn Bas a2 Lhrr Faai lI Tai hm oda H ee Fade Dia ee Lem Pae M Fa lim npa iva eH Ha ihn Dow IH Ler Forum L5 Bales ma BW ee Bele La EPIN lhe Barus He His i bma Tora B SOME Hlb Ee APIS Lees Fee Ba Leos Lia BIdd ete leer Geile ae lbr Pem Yi Hale Dore Bl fa ni HET Halhin Doe ae iher Bore Si Haike Lra Alfa H Pibe Ra anni ibam Fem 21 Vin i bam pta EIU o EJ Ha lbn Lrg ur iher Freee Hal bam ra Edd CHARTS Fed bam Dong pem lbe Fami Ha Lier Shag Bld ee dH He Line LE ADS lbe Free Faibn Srg Hi EHE Halbe Pers a lh Parum Fa Li ord Bia ste Halban oy a Lear Farum Di Vin lem rona W eee Pike oy p bee Panga J LIT Jey Hy n ihe piy H eae Pyr Ha iket Bldg rH a Hele ey Ag bbam Pee 7 Vin tiam La Er og EI belie ors ee Pee bin ibm ose Bd oo YB ee Eig AG Lb Been Minbar icy DEDE oe ie Lee Do A Uem Ree He ir Md eh Amie c4 AI lbe Peg lie data BA ath rr Hae hee Da Al iber Pores 2 km teat
12. Communication Error References Communication Profile Test Show Error Log p 14 p 15 p 15 p 16 p 17 p 17 p 18 p 18 p 19 p 20 p 20 IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 l Warning and Caution DISCLAIMER OF WARRANTY Magnetek s Electromotive Systems hereafter referred to as Company assumes no responsibility for improper programming of a drive that resulted from use of this software This software should only be used by a trained technician who has read and understands the contents of this manual Normal use of this software may result in the drive parameters becoming modified Improper programming of a drive can lead to unexpected undesirable or unsafe operation or performance of the drive This may result in damage to equipment or personal injury Company shall not be liable for economic loss property damage or other consequential damages or physical injury sustained by the purchaser or by any third party as a result of the use of this software Company neither assumes nor authorizes any other person to assume for Company any other liability in connection with the sale or use of this software A WARNING 1 Read this user manual in its entirety before installing IMPULSE LINK 4 1 Basic Software or operating the IMPULSE G VG Series 2 IMPULSE G VG Series 3 and or IMPULSE P3 Series 2 Variable Frequency Drives VFD 2 DO NOT connect or disconnect wiring or perform signal checks while the electr
13. ParFle par a ine ET Fumar 2 CDU OA ud aue rS DODGE ae m DE dn VeRO nil LBEo dtr leri F ET m ee ea Sarg ing DITE Lori ajj Ey ascen iow T E gu OR m Alio Sector Orga d xr Lees kid TOberbangepge Ging d Cuber Aer Gee L Jo cbane La px deal Lan kii Arren paesi e ced Lew j eet cadsarnrd Level AB Sorc menus If entes 1 3 Dpr Lie H kk lone rehi fae i l 2A Litas ier Se reum LS HF oR ae EEL eue a LZ PES i Dai Ls AHH iadh acie ene B EL Lr ke karia 121 n tb d Ean t ABE PA rE TH bht 2 yrn VH Ene EL ee CUm branded Fe SH Crus bce Ai Eu dE D nop Use ded Ek Etr FHF Lomia T yam Dol es AHA De Lil J v Loki k MESS scar Locked Seo far Loca NI Uem Pa i i Vii Lice Ta E141 CHEST MEDIE Dx E ri LE hiii 1 Mi Li Tei BLIA H Pi hee Ee A tem Pile Hi Lice JF EKAI HA Pld Wie IE ee nhia H La SE MISMA HE PH EE DEI A the Pi ie Ha Ls ES IHI HE ies IE I ADE Lus Vul PEL IE BA H ee DE AA m Fh Hie Dra nA He i Deme Dd A Le Fake PE ere La HRS Phe DEN ADi LA ham Hi Lom EEI BA CHORI D Qe Did MZ Like Fait Vh Lid EA EMMRIO Phi Cee L Ae Lhe Pikia Phi Lii Si SiS OH H Lee Dah Atel Lice F gus Halm Ei EH ee ed Le Ded ARD L Flin be H Lc 0C Si Coe E Ei A Dh Fm um Vis Lice dca PH SRI ld Lines L4 A hi Pan ee Ha Lum ria l HE Ba ee Ld A Lik Fi ae Ba Lie a Lo ee Jaen Hem aun Hid Laer 44 Bit HES H Kies ER A Lie uam Halam Dna SU He Pie Who Len AHE Lem named Ha Lar 4a BNA eH H i ACIE Le Pi es E Ha Liem Lda BM
14. ation Profile Test U BENI Bequesting Port Connection Granted Opening Connection Done Testing Loophack 0EF Testing Register OxlOo 0F Checking for Gt VGt Series 3 0E Checking Gt VGt Series 3 RBRevizsion UE Detected DriveType Gt VGtr Series 3 Flash ID 8001 3 Weise P feng Link Wires Merson 4 102 Duki 57 Deginr ng Wrke Parareters Dre T wpe za ER Seres 34200 e Flash D 8505 3 Pia ana ema par Wte Parameters Sutter Show Error Log This function also found in the Tools drop down menu brings up an additional window showing the status of IMPULSEeLINK 4 1 Basic IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 20
15. es 2 IMPULSE G VG Series 2 and 3 drive faults as shown below Impulse Link 4 1 Help In x e M e Hide Back Home Frint Options Contents Index h E Index Search Brake Ans Lost Communication Profiles Du Troubleshaoting Fault Code Fault or Indicator Name Description Corrective Action E u Drive Fault Reference BEO Brake answer back signal is lost 1 Check brake answer di Q G VG Series 2 during run While running the multi back circuit I ee flashing eld GG Serias 3 Ea 2 Check terminal status i Brake A function input brake answer back is lost 2 BB Base Black i p U1 10 Lost z BEU Brake Ans Lost 8 BE1 Rollback detec BE2 No Current BE3 Brake Release BE4 Brake Answer 1 rm BE5 Brake Answer BEG Brake Stop Ala 8 BE Brake Welded 2 BUS Option Com Er 7 CALL SFF G Com C CALL Cam Call Can t Run Drive nati 2 Can t Switch Matar F E CE Memaobus Cam I CF Control Fault g H Mmi Co m ee aa A aa T Y 4 m COMMUNICATION ERROR REFERENCES The Help function provides an overview of the possible errors that could occur while running IMPULSE LINK 4 1 Basic as shown here Impulse Link 4 1 Help _ m m e zi Hide Back Home Print Options Contents Index Search IL Settings Baud Riate Cammur Channel
16. ical power is turned ON 3 Improper programming of a drive through the use of this software can lead to unexpected undesirable or unsafe operation or performance of the drive Failure to observe these and other precautions indicated in this manual will expose the user to high voltages resulting in serious injury or death Damage to equipment may also occur A CAUTION NOTICE No patent liability is assumed with respect to the use of the information contained herein Moreover Magnetek is constantly improving its high quality product therefore the information contained in this manual is subject to change without notice Every precaution has been taken in the preparation of this document Nevertheless Magnetek assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained in this publication IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 2 Chapter 1 Introduction OVERVIEW IMPULSEsLINK 4 1 Basic is a user friendly Windows based interactive drive communication software It is designed specifically for communication between Magnetek s IMPULSE G VG Series 2 IMPULSE G VG Series 3 IMPULSE P3 Series 2 drives and your PC with the supplied cable The IMPULSEsLink 4 1 Basic Software allows you to upload download parameters program and monitor your IMPULSE drives The IMPULSEeLINK 4 1 Basic Kit Part 157 10028 contains the following components
17. ing a drive remotely you need to be sure that all personnel and or operators are notified Once you have checked the I accept box the Continue Fault Reset button will be available WARNING Confirm Reset EJ I Accept This Function will rezet the current drive Fault Proceeding with this Functian could cause an unexpected undesirable condition All operators and or pe notified prior to resetting accept and proceed wit acknowledging that rese Fault condition may lead personal injury or ewe 4 1 Accept This Function will reset the current drive Fault Proceeding with this Function could cause an unexpected undesirable or unsafe operating condition All operators and or personnel should be notified prior ka resetting the Fault IF you accept and proceed with this Function you are acknowledging that resetting the current drive Fault condition may lead to equipment damage personal injury or ewen death Accepr Continue Fault Reset Fault Reset Icon ls Shop Crane bridge Driv X Demo Drive GT Series 3 230 3 20 4 Flash 201 3 haces zu Control Methad D v re control hot Temna ocd000000 Output Termina 100060000 Frequency Reference 15 00 He Output Frequency ggd He Output Current 0 0 Amps Output Voltage DO VAC Bus Voltage 318 wDcC Torque Reference Q0 6 Qutput Speed Q D He e Mo
18. ion Impulse Link 4 1 InstallShield Wizard ugbup ub EL SLT Free Updates Patches Additional features and bug fixes may be available from time to time These may be downloaded from the Magnetek Material Handling website at www magnetekmh com mg support downloads software htm Software Removal To remove the IMPULSE LINK 4 1 Basic Drive Interface Software open the Control Panel s Add Remove Programs dialog box double click the IMPULSE LINK 4 1 Basic entry and choose Remove All from the IMPULSE LINK 4 1 Basic Setup dialog box IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 4 CONNECTING TO YOUR PC Use the appropriate cable provided in your IMPULSE LINK 4 1 Basic kit to connect your PC to the drive For IMPULSE G VG Series 2 drives 1 With power off remove the keypad from the front corner of the drive 2 Connect the female connector into the drive s keypad receptacle 3 Attach the DB 9 connector end of the cable to the serial communication port on the PC For IMPULSEeP3 Series 2 and IMPULSE G VG Series 3 drives 1 With the power off remove the keypad 2 Connect the RJ45 plug into the drive s keypad receptacle 3 Attach the DB 9 connector end of the cable to the serial communication port on the PC CREATING COMMUNICATION PROFILES USING THE WIZARD The communication profile consists of the settings available to establish communication to the IMPULSE drives There is a wizard available to assist yo
19. iptions and visual programming modifying parameters from your computer has never been easier Read from the VFD allows you to load the parameter values from the drive s memory This can be accomplished through the VFD drop down menu or the Read Icon as shown below i IMPULSE Link 4 1 Basic ParFile1 ge settings VFO Tools Window Help mock v 3 B CE geadfom vro Crh E 8 sre ven Chien Properties Plead x Miu EF yo z p A i i i AO Acceus Level Advanced Level l o u lu Ai42 Control Method Geen loos Ves 2 Kk ALGI MoGun Standard Hoi a a X GISO Multi Sieg Btn iritixkre Reading Drive Parameters 16755 Cancel Write to VFD saves all parameter values from memory to the VFD Again this can be accomplished via the drop down on the VFD menu or using the Write Icon as shown here Writing to VFD may result in undesirable operation of your crane causing danger personal injury or death To proceed with the write to VFD function you will need to accept that you acknowledge the warning message as shown here Once you have checked the I Accept button the Continue write to VFD button will be available i IMPULSE Link 4 1 Basic ParFile1 I Eie Getting VFO Ik Widow Hep uu a do ce nena rifle D ES B E irl Properties Phe Wri verts Parameter Fila To VFD 4s WARNING Confirm Write Theat Furalion a
20. its current file name and location Save As Saves the active file with a different file name or location Print Preview Shows how a file will look when you print it Print Prints the active parameter set Select Print options in the Print window dialog box Properties Displays the properties box to view the properties of the active file Exit Closes this program after prompting you to save any unsaved files Communication Allows communication profiles to be added removed edited copied imported and exported Preferences IMPULSE LINK 4 1 Basic settings for access level IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 8 VED i Read from VFD Ctrl B Write to VED Ctr D Tools ke Lonvert ampare Communication Test b Monitor keypad Simulator Show Error Lag Write Flash Allows a binary file to be written to VFD flash memory FACTORY USE ONLY Read from VFD Loads all parameter values from the VFD to memory Write to VFD Saves all parameter values from memory to the VFD Convert Allows for parameter files to be converted from one software Flash ID to another must be within the same series Compare Parameters Allows for comparison of sets of parameter files Communication Test performs a communication test with the VFD Monitor Displays a select number of monitor parameters U parameters updated continuously Keypad Simulator
21. l 2 01 2006 6 GETTING STARTED Run IMPULSEeLINK 4 1 Basic by clicking on the L icon found on your desktop A splash screen will appear for a few seconds while the subsystem loads Loading Plugins Select the profile that you created in the drop down profile box as shown here and you are ready to access your IMPULSE drive IMPULSE Link 4 1 Basic File Settings WFD Tools Window Help E a Prot Y Bridge 1 B i Au Default Profile F i Properties Read Write Help IMPLILSE Link 4 1 Basic IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 7 Chapter 3 Navigation The IMPULSE LINK 4 1 Basic Software is a Windows based software with easy to use menus and drop down functions The user is able to access utilities for uploading downloading parameters comparing parameters saving parameters to a file and more from the easy to navigate toolbar IB IMPULSE Link 4 1 Basic Baa File Settings vFD Tools Window Help File Mew Ctr M i Open Ctri o Close Save AS Print Preview amp p Print Ctrl P 2 Properties Exit Settings Communication Preferences New Displays the controller properties dialog to create a new factory default parameter set based on the drive type software number model and kVA Open Opens or finds a file containing a parameter set for a specific drive type and software number Save Saves the active file with
22. ll cwerverila tha curren drive p r amelers Proceeding with this function Thould be done will caution as changing drive parameters ray lead to unexpected undesirable or unzafe operation of the drive All operators and or personal should ba noted of any parameler change that may affect pe get is pr TAdvanced Level Cars esd Open Leon Ve Motor Landed Hait Zone Bel PD Millie thould be done with caution as changing drive parameters may lead bo uriaxpached undatirable of unca operation of the drive All operators and or pertonmel should be notified of any paramaeber charges that may affect oper ation inti gree ery Sete isime inter Peaid 1 Lrizched IF you accept and proceed with thr funcban pou are acknowledging that owenwriing dria paraenaters miiy lead to equipment damage personal inpary or even death Enba Password 2 Lesen x cien Mikal TIT horis 3 Fluch ID 8003 5 E Rie IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 11 Modified Constant A parameter with blue text implies that its value is different than its default setting This list should match the modified constants list in the drive with the exception of Al parameters Read Only A grayed out highlighted parameter implies that it cannot be modified This can happen for the following reason The Access Level of the current parameter set is lower than what is needed for this
23. ntong Fauked Fault Icon 1 Basic Instruction Manual 2 01 2006 14 Chapter 6 Additional Menu Features PRINT PREVIEW IMPULSEeLINK 4 1 Basic provides a compact printing mode that displays all drive parameters in only 1 2 pages It also prints a more detailed mode that lists descriptions as well as units for each parameter Compact Parameter Print Preview E Pring Presiesus m eee lum FErreeerreeerre I I ei a i ri R i Li Lua Es E F Sin eet Cost E m Li ima lam lma li ii j krun b b anna d Vias mm uin bi d Erm Tli bin i mar on n A F i alum E ee DU Tig E TEAM ki acum bg E Lana EFI SS Le i E hene Ei lim i rj BE al Seer Bode P i mu omm oma Fi il ima oo mg m Ae d LIT aT LI ik os Lo LI Cal mm aol Vin Lote Lun TE E AT Sa Lie Loin i Hi ioe Dun Fu i mm om i bp iam om n F E a maium Dau Fiii r ry ai micum jur Ru Ls en LS Pole TN Lu stes Lo mis LA Vin oum Luin rn Print Printer Name MpcserpiMFCANZW Ready Canon iR3570 iR4570 PSs 138 207 8 137 PRINT Canon IR45 0 Balbus Type Where Comment Page Range Print hat all oO Current page Print Mode Seiechion Application Copies Job Number Number of copies Preview Customer Name icuste rises Detailed Parameter Print Preview mi Ti Cem 1 me 5 L mI E oe Die am m WEN S58 Rey idm bE heim mu PTT UE a koun pnm Je arm ud i acm ran Fan Numi dup
24. ted via the RS485 connection a CF00 Comm Error will occur Digital Operator Emulator NOTES 1 To Activate Select the correct drive profile from the dropdown and click the button 2 The RUN command has been disabled for safety reasons 3 If the drive is put into Program Mode and not returned to Run b E Mode the user will be unable to run the drive JVOP 140 V0 20 ES 3 Sexes 2 RLIN Y okese IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 16 VIEWING PARAMETERS The View drop down box allows you to select how the parameters are viewed as shown below all modified or another sub group IMPULSE Link 4 1 Basic ParF ile1 E File Settings VFO Tools Window Help E m Profle d Default Profile v Efex f X 4129 Properties Read Write Help Modified Constants Group 4 Initialize Group B Application Group C ESI Special Functions Group D Tuning Group E Motor Group F Options Group H Terminal Init Parameters A1 05 CDO VF Setting Limit 0 English a EM 2 Advanced Level z D 2 Open Loop Ve i 1 Standard Hoist 1 3 5PD Multi Step 0 No Initialize A1 06 Enter Password 1
25. u setting up the communication profile In the Settings Menu click Communication and then New You will then see the following screen appear RS237 Serial Communication Wizard Introduction The R5232 Wizard will help you set up an RSz32 connection profile For your IMPULSE Drive IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 5 Highlight the IMPULSE drive RS 232 for the communication through the keypad port and then click Select The wizard will then take you through the following three steps to set up a new communication profile Step 1 Name Description Crane and Motion Step 2 Common Port Protocol Slave Address Baud Rate Parity Step 3 Finish RS232 Serial Communication Wizard Step 1 To keep your profiles organized additional Fields have been included These are optional selections Type IMPULSE Drive R5232 Communication Modify the communication options for your R232 Connection IMPULSE Drive communication constants are also shown Comm Port Communications Port COMI w Communications Port OMi Protocol Keyspan USE Serial Port COM4 Slave Address Ox1F Baud Rate 9600 Parity MOME he iz FEiricr RS232 Serial Communication Wizard Finished The R5232 Wizard is Finished collecting information Ta build Ehe New Profile 1 communication profile press Finish IMPULSE LINK 4 1 Basic Instruction Manua
26. ustomer Name Application and Job Number fields appear on the printout NOTE Only parameters that are viewable in the Parameters Window will be printed IMPULSE LINK 4 1 Basic Instruction Manual 2 01 2006 15 PARAMETER FILE CONVERSION Convert under the Tools menu allows for parameter files to be converted from one software Flash ID version to another within the same drive series Parameter File Conversion Ed Convert From No File Selected Source Specifies the file to be converted Select the Parameter File vau wish Eo convert by 5 urce clicking on the Source button Flash ID Specifies the software type that the file will be converted to Destination Filename Specifies the Convert To No File Selected Destination filename Flash ID cepere Menem GU PME te eesti Convert Converts the parameter file specified in uno MEINE EGO USENET IOS UAE Source to the format specified in the software Destination button 2 version in the Flash ID The converted file is saved to the filename and path specified in Destination Filename JVOP 160 Eg PAD REW SEG REF ALARM REMOTE Keypad Simulator The keypad simulator emulates the IMPULSE P3 Series 2 or IMPULSE Series 2 or 3 keypad which allows for remote keypad menu navigation This function is available when connected via the drive s keypad connector not with RS485 connection If you attempt to run the keypad simulator while connec
27. will pop up for hexadecimal and binary parameter values The window provides the actual parameter value description so that you won t need to use the technical manual to translate a hexadecimal or binary value Simply click the mouse on the table to modify and then click on the OK box or hit enter to accept the change Click the Cancel box or ESC to cancel the change NOTES 1 Ifachange is made ENTER is not pressed to accept it and the user clicks on another row or column the value will revert back to what it was before the change 2 Ifa parameter is changed to an invalid value under the minimum value or over the maximum value an appropriate message will be displayed and the value being edited will revert back to what it was before the change PARAMETER FILE COMPARISON The Parameter File Comparison function found in the Tools drop down menu allows for compariso of sets of parameter files The Show drop down allows you to compare all parameters of each file only parameters with different values or only parameters with equal values SECURITY PASSWORD PROTECTION The Preferences drop down menu in IMPULSE LINK 4 1 Basic software allows you to set the access level username and password By logging out of the Advanced mode you will be in the User mode While in the User mode the drives can only be monitored Write to VFD and Reset functions available PAR Fe Campore ParFiel par lo

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SMART CAMERA MV900F Užívateľská príručka  Wireless (Sem fios) - produktinfo.conrad.com  Baja de Mobiliario y Equipo en los organismos de la Administración  Version 4.0 Bedienungsanleitung  - A.J.Pinto  XC02 User Manual  Bewahren Sie diese Gebrauchsanweisung bei dem Coolfog  Bushnell 20-3031 Film Camera User Manual  ! WARNING - Napoleon® Products  Kenwood KRC-308S Car Stereo System User Manual  

Copyright © All rights reserved.
Failed to retrieve file