Home
Moxa ToughNet Switch TN-5524-8PoE Hardware Installation Guide
Contents
1. Pin Signal Pin Signal 1 Tx 1 Rx 2 Tx 2 Rx 3 Rx 3 Tx 6 Rx 6 Tx M12 4 pin M to M12 4 pin M Cross Over Cable Wiring Txt 1 Rx 2 Tx 3 Rx 4 Cross Over Cable Wiring BRON PST RX TX Rx M12 4 pin M to M12 4 pin M Straight Trough Cable Wiring Straight Through Cable Wiring AUN RX TX RX Tx M12 4 pin M to RJ45 8 pin Cross Over Cable Wiring Cross Over Cable Wiring Tx Rx Tx Rx BRWN Own Tx TX RX Rx M12 4 pin M to RJ45 8 pin Straight Trough Cable Wiring Tx Rx Te Rx D AUN LED Indicators m Straight Through Cable Wiring Rx Rx TX OUN Several LED indicators are located on the ToughNet switch s front panel The function of each LED is described in the table below LED Color State Description PWR1 AMBER ON i D Power is being supplied to power input PWR1 OFF Power is not being supplied to power input PWR1 PWR2 AMBER ON Power is being supplied to power input PWR2 OFF Power is not being supplied to power input PWR2 FAULT RED ON When the corresponding PORT alarm is enabled and a user configured event is triggered OFF When the corresponding PORT alarm is enabled and a user configured event is not triggered
2. Bottom View Side View Screw holes for panel mounting kit Console port Grounding screw Relay output port Power input voltage range indication Power input port male 6 pin shielded M23 connector PWR1 LED for power input 1 PWR2 LED for power input 2 FAULT LED MSTR HEAD LED for ring master or chain head CPLR TAIL LED for ring coupler or chain tail TP port s 10 100 Mbps LED 10 100BaseT X port female 4 pin shielded M12 connector with D coding 10 100BaseT X PoE port female 4 pin shielded M12 connector with D coding LED for PoE port Mounting Dimensions 390 15 35 350 13 78 100 3 94 72 2 83 97 2 3 83 132 5 20 eoo e eoo eoo e90 9 97 2 3 83 Sra pasri 122 3 4 81 E AAA rm m fm o o Unit 2 mm inch LL Panel Wall Mounting STEP 1 Mounting the TN 5524 8PoE switches to a wall requires 4 screws Use the ToughNet switch as a guide to mark the correct positions of the 4 screws STEP 2 6 0 7 0 mm Use the 4 screws in the panel mounting kit If you would like to use your own screws make sure the screw head is between 6 0 mm and 7 0 mm in Ha diameter and the shaft is less than 4 0 mm in 4 0 mm diameter as shown at the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the ToughNet sw
3. 802 1D for Spanning Tree Protocol IEEE 802 1w for Rapid STP IEEE 802 1Q for VLAN Tagging IEEE 802 1p for Class of Service IEEE 802 1X for Authentication IEEE 802 3ad for Port Trunk with LACP Protocols MIB IGMP v1 v2 device GMRP GVRP SNMP v1 v2C v3 DHCP Server Client DHCP Option 66 67 82 BootP TFTP SNTP SMTP RARP RMON HTTP HTTPS Telent SSH Syslog LLDP IEEE 1588 PTP Modbus TCP IPv6 MIB II Ethernet like MIB P BRIDGE MIB Q BRIDGE MIB Bridge MIB RSTP MIB RMON MIB Group 1 2 3 9 Flow Control Switch Properties Priority Queues Max Number of Available VLANs IEEE802 3x flow control back pressure flow control 4 64 VLAN ID Range VID 1 to 4094 IGMP Groups 256 Interface Fast Ethernet Front cabling M12 connector 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection Console Port M12 A coding 5 pin male connector System LED Indicators PWR1 PWR2 FAULT MSTR HEAD CPLR TAIL Port LED Indicators 10 100M Fast Ethernet port Alarm Contact Two relay outputs in one M12 A coding 5 pin male connector with current carrying capacity of 3 A 30 VDC 11 Power Requirements Input Voltage Input Current 24 VDC 16 8 to 30 VDC Max 8 4 A 24 VDC Connection M23 6 pin male connector Overload Current Present Protection Reverse Polarity Present Protection Physical Characteris
4. 75 C and tighten to 4 5 pound inches For use in pollution degree 2 environments 2A Safety First Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Be sure to read the following guidelines e Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring through the same wire conduit To avoid interference wires with different signal characteristics should be routed separately e You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together e Keep input wiring and output wiring separated e We strongly advise that you label wiring for all devices in the system Grounding the ToughNet Switch Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the grounding screw to the grounding surface prior to connecting devices 6 8000 0000 8686 A This product is intended to be mounted to a well grounded mounting surface such as a met
5. Moxa ToughNet Switch TN 5524 S8POoE Hardware Installation Guide Layer 2 M12 Managed PoE Ethernet Switches Second Edition April 2014 2014 Moxa Inc All rights reserved P N 1802055240011 Overview The ToughNet TN 5524 8PoE series M12 managed Ethernet switches are designed for industrial applications in harsh environments The TN series Switches use M12 and other circular connectors to ensure tight robust connections and guarantee reliable operation against environmental disturbances such as vibration and shock The TN 5524 8PoE series Switches provide 24 Fast Ethernet M12 ports 8 of which are 10 100BaseT X PoE compliant TN 5524 8PoE switches provide up to 15 4 watts of power per PoE port and allow power to be supplied to connected devices such as surveillance cameras wireless access points and IP phones when AC power is not readily available or is cost prohibitive to provide locally Models with an extended operating temperature range of 40 to 75 C are also available The TN 5524 8PoE series Ethernet switches are compliant with EN50155 50121 3 2 50121 4 railway applications making the Switches suitable for onboard train applications Package Checklist Your ToughNet TN 5524 8PoE switch is shipped with the following items If any of these items is missing or damaged contact your customer service representative for assistance e 1Moxa ToughNet switch e Hardware installation guide e CD ROM with user s manu
6. al Windows utility and SNMP MIB file e Moxa product warranty statement e M12 to DB9 console port cable e 2 protective caps for console and relay output ports e Panel mounting kit Features Anti Vibration Circular Connectors for Robust Links e M12 D coding 4 pin female connectors for Fast Ethernet 10 100BaseT X ports e M12 A coding 5 pin male connectors for console and relay output e M23 6 pin male connector for power input Isolated Power Input e Supports 24 VDC 16 8 to 30 VDC isolated High Performance Network Switching Technology e IPv6 ready certified by the IPv6 Logo Committee e IEEE 1588 PTP Precision Time Protocol for the precise time synchronization of networks e DHCP Option 82 for IP address assignment with different policies e Modbus TCP industrial Ethernet protocol e Turbo Ring Turbo Chain and RSTP STP IEEE802 1w D e IGMP Snooping and GMRP for filtering multicast traffic from industrial Ethernet protocols e Port based VLAN IEEE802 1Q VLAN and GVRP protocol to ease network planning e QoS IEEE802 1p 1Q and TOS DiffServ to increase determinism e 802 3ad LACP for optimum bandwidth utilization 25 IEEE802 1X and https SSL to enhance network security SNMP v1 v2c v3 for different levels of network management RMON for efficient network monitoring and proactive capability Bandwidth management prevents unpredictable network status Lock port restricts access to authorized MAC addresses only Port mirror
7. al panel Connecting the Power Supplies The ToughNet TN 5524 8PoE series switches support one power supply The M23 6 pin male connector on the TN 5524 8PoEfront panel is used for the power input Pinouts for the power input port on the TN 5524 8PoE PIN Pinouts for the power input port on the TN 5524 8PoE Pin Description Usage Connect PWR1 Live DC to the Live terminal when using an AC power source or to the positive terminal when using a DC power source 1 PWRI1 Live DC Connect PWR1 Neutral DC to the Neutral terminal when using an AC power source or to the negative terminal when using a DC power source 2 PWR1 Neutral DC Connect the Chassis Ground to the safety 3 Chassis Ground ground terminal for AC inputs or to the equipment ground bus for DC inputs STEP 1 Plug your power cord connector to the power input port of the TN 5524 8PoE switch STEP 2 Screw the nut on your power cord connector to the power input connector on the switch to ensure a tight connection eres Before connecting the TN 5524 8PoEto the power input make sure the power source voltage is stable Connecting the Relay Outputs Each TN 5524 8PoE switch has two sets of relay outputs relay output 1 and relay output 2 The M12 A coded 5 pin male connector on the TN 5524 8PoE s front panel is used for the two relay outputs Use a power cord with an M12 A coded 5 pin female connec
8. ing for online debugging Automatic warning by exception through email relay output Automatic recovery of connected devices IP addresses Line swap fast recovery LLDP for automatic topology discovery through network management software Configurable through Web browser Telnet Serial console and Windows utility Designed for Industry specific Applications Power failure port break alarm by relay output EN50155 EN50121 3 2 EN50121 4 40 to 75 C operating temperature range for T models IP40 rugged high strength housing Panel mounting mounting installation capability Recommended Optional Accessories CBL M23 FF6P OPEN BK 100 IP67 1 meter M23 to 6 pin power cable with IP67 rated female 6 pin M23 connector PLG WPM23 01 IP67 M23 cable connector female 6 pin crimp type CBL M12D MM4P RJ45 100 IP67 1 meter M12 to RJ45 Cat 5E UTP Ethernet cable with IP67 rated male 4 pin M12 D coded connector CBL M12 FF5P OPEN 100 IP67 1 meter M12 to 5 pin power cable with IP67 rated female 5 pin M12 A coded connector M12D 4P IP68 Field installable M12 D coded screw in connector male 4 pin IP68 rated M12A 5P IP68 Field installable M12 A coded screw in connector female 5 pin IP68 rated CAP M12F MIP67 PAK04 Caps for M12 D coded 4 pin male connectors metal and IP67 rated 4 pieces in one pack TN 5524 8PoE Panel Layouts Mo 0 0 Ao d ONAMWRWNH dom s d 14 Front View 13 6666 6666 ooc0
9. itch between the wall and the Screws NOTE Before tightening the screws into the wall make sure the screw head and shaft size are suitable by inserting the screw through one of the keyhole shaped apertures of the ToughNet switch STEP 3 Once the screws are fixed in the wall hang the ToughNet switch on the 4 screws through the large opening of the keyhole shaped apertures and then slide the switch downwards Tighten the four screws for added stability eeece6 66060606090 9000900 966606896 o 6609090 960060096 occo seoooo0o0 NOTE To provide greater protection from vibrations and shocks use screws with shaft diameter between 6 0 mm and 7 0 mm and fix the ToughNet switch onto the wall directly through the large opening of the keyhole shaped apertures Wiring Requirements WARNING Turn the power off before disconnecting modules or wires The correct power supply voltage is listed on the product label Check the voltage of your power source to make sure you are using the correct voltage Do NOT use a voltage greater than what is specified on the product label These devices must be supplied by a SELV source as defined in the Low Voltage Directive 2006 95 EC and 2004 108 EC A omo Safety First Be sure to disconnect the power cord before installing and or wiring your Moxa switch This device has UL508 approval Use copper conductors only 60
10. or when the corresponding PORT alarm is disabled MSTR HEAD GREEN ON When the TN switch is either the Master of this Turbo Ring or the Head of this Turbo Chain Blinking OFF When the TN switch is Ring Master of this Turbo Ring and the Turbo Ring is broken or it is Chain Head of this Turbo Chain and the Turbo Chain is broken When the TN switch is neither the Master of this Turbo Ring nor the Head of this Turbo Chain CPLR TAIL GREEN ON When the TN switch enables the coupling function to form a back up path in this Turbo Ring or it is the Tail of this Turbo Chain Blinking When the Turbo Chain is down OFF When the TN switch disables the coupling function of Turbo Ring or it is not the Tail of the Turbo Chain 10 LED Color State Description AMBER TP 10 100M GREEN PO D TP port s 10 Mbps link is active Data is being transmitted at 10 Mbps ON Blinking Off On Blinking TP port s 10 Mbps link is inactive TP port s 100 Mbps link is active Data is being transmitted at 100 Mbps off TP port s 100 Mbps link is inactive PoE AMBER Power is being supplied to a Powered on Device PD Power is not being supplied to a Powered Of Device PD Specifications Technology Standards IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X IEEE 802 af PoE IEEE 802 3x for Flow Control IEEE
11. tics Housing Metal IP40 protection with protective caps on unused ports Dimensions W x H x D 390 x 132 x 122 3 mm 15 35 x 5 20 x 4 81 in Weight TN 5524 8PoE Series 5330 g Installation Panel mounting Environmental Limits Operating Temperature Wide Temp Models 40 to 75 C 40 to 167 F Storage Temperature 40 to 85 C 40 to 185 F Operating Humidity 5 to 9596 non condensing Regulatory Approvals Safety UL508 Rail Traffic EN50155 EN50121 3 2 EN50121 4 EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD level 3 EN61000 4 3 RS exceeds level 3 EN61000 4 4 EFT level 3 EN61000 4 5 Surge level 3 EN61000 4 6 CS level 3 EN61000 4 8 Shock IEC61373 Freefall IEC60068 2 32 Vibration IEC61373 Note Please check Moxa s website for the most up to date certification status WARRANTY Time Period 5 years Details See www moxa com warranty Technical Support Contact Information www moxa com support Moxa Americas Toll free 1 888 669 28 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel Fax 49 89 3 70 03 99 0 49 89 3 70 03 99 99 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 72 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 12
12. tor to connect the relay contacts You can purchase an M12 power cable from Moxa the model number is CBL M12 FF5P OPEN 100 IP67 Pinouts for the relay output port on TN 5524 8PoE The two sets of relay contacts of the M12 A coded 5 pin male connector are used to detect user configured events The two wires attached to the fault contacts form an open circuit when a user configured event is triggered If a user configured event does not occur the fault circuit remains closed Connecting the Data Lines 10 100BaseT X Ethernet Port Connection All TN 5524 8PoE models have 24 10 100BaseT X Ethernet ports 4 pin shielded M12 connector with D coding The 10 100TX ports located on the TN 5524 8PoFfront panel are used to connect to Ethernet enabled devices Most users configure these ports for Auto MDI MDI X mode in which case the port s pinouts are adjusted automatically depending on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port In what follows we give pinouts for both MDI NIC type ports and MDI X HUB Switch type ports We also give cable wiring diagrams for straight through and cross over Ethernet cables Pinouts for the 10 100BaseT X Ports on the TN 5524 8PoE PIN TX E Tp 2 RD B Tb 1 RD Housing Shield Pinouts for the RJ45 8 pin Port 8 pin RJ45 MDI Port Pinouts MDI X Port Pinouts
Download Pdf Manuals
Related Search
Related Contents
印刷される方はこちらをご覧ください(PDF形式、257kバイト) Samsung NB-NH Brugervejledning 緊急遮断システム Simpson Strong-Tie LTP4 Installation Guide Trendnet TEG-S24G network switch A.O. Smith WATER HEATERS Instruction Manual South Shore Furniture 3577A2 Instructions / Assembly Service Manual Template Alptec 2444d Copyright © All rights reserved.