Home

Manual

image

Contents

1. 1 2 Remove the top back cover photo 3 and insert the lamp photo 4 The lamp used is manufactured from quartz glass and should be handled with care Always adhere to the instructions supplied in the lamp s packaging Never touch the glass directly but use the tissue provided in the lamp s packaging The Gy 9 5 lampbase is asymmetrical DO NOT USE UNDUE FORCE ON THE GLASS In case of difficulty re read the instructions and repeat the procedure Photo 3 Photo 4 No lamp allignment needed 4 VOLTAGE AND FREQUENCY Profilo Compact Halogen operates at 230V 50 60 Hz 5 INSTALLATION Profilo Compact Halogen may be either floor or ceiling mounted For ceiling mounted installations we reccomend the use of appropriate clamps to fix the unit to the mounting surface A safety cable must always be present 7 PROFILO COMPACT ceiling installations Floor installations WARNING The rear side of the unit can reach very high temperature Handle the projector with extreme caution 5 5 Ambient temperature The projector should never be installed in places that lack a constant air flow The ambient temperature Should NOT exceed 35 C 6 MAINS CONNECTION PROFILO 500 operates at 230 VOLT 50 60 Hz Prior to connecting the unit to your mains supply ensure that the model in your possession correctly matches the mains supply available For connection purposes ensure that your plug is capable of supporting 6 amps at 230V
2. 541 611131 Fax 39 0541 611111 info dts lighting it www dts lighting it
3. PROP LO COMPING LAWS AKO Halogen lamp User Manual ver 1 0 2 PROFILO COMPACT Le informazioni contenute in questo documento sono state attentamente redatte e controllate Tuttavia non assunta alcuna responsabilit per eventuali inesattezze Tutti i diritti sono riservati e questo documento non pu essere copiato fotocopiato riprodotto per intero o in parte senza previo consenso scritto della D T S D T S si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche funzionali o di design a ciascun proprio prodotto D T S non assume alcuna responsabilit sull uso o sull applicazione dei prodotti o dei circuiti descritti The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles inexactitudes Tous droits reserves Ce document ne peut tre copi photocopi
4. Strict adherence to regulatory norms is strongly recommended 6 1 Protection The use of a thermal magnetic circuit breaker is recommended for each Profilo Compact Halogen A good earth connection is essential for the correct operation of the projector 7 PROJECTOR USE 1 1 Focus and zoom adjustment lenses are located on the front side of the unit Place the projector on the object to illuminate loose the fixing lenses knobs adjust the lenses position till the projection is whell focused on the object Thighten the knobs 1 2 Blades Profilo compact is provided with four indipendent steel blades The blades let you create geometrical figures with the light Light beam with no blades inserted Light beam with blades inserted 1 3 Blades insertion To insert the blades on the unit proceed as follow Locate the blades holder place one side of the blade within the two parallel surfaces push and tilt it on the guide Blades holder Parallel surfaces 9 PROFILO COMPACT 8 OPENING THE PROJECTOR HOUSING It is possible to inspect the inside of the projector by removing the cover as indicated below Attention REMOVE MAINS POWER PRIOR TO ACCESS THE PROJECTOR S INTERNAL COMPONENTS Back side 1 Loose the screw and the knob located on the top back side of the unit photo 1 and 2 2 Remove the top back side cover photo 3 Photo 1 Photo 2 Photo 3 FRONT SIDE focus zoom lenses 1 Loose the knob lo
5. c condenser Linear Focus Linear Zoom 20 40 Metal Filter Holder 450mm 150mm Metal protection grid No internal Fans Internal profiler built up with four indipendent steel blades Weight 7 5 Kg Dimensions mm 325 PROFILO COMPACT mm 173 ACCESSORIES C Clamp G50 black max Load 10Kg cod 0521A012 C Clamp G30 chrome max load 10Kg cod 0521A012 20 Safety wire 3mm x 60 cm ring spring catch max load 60Kg cod 0521A010 LAMP 300W 230V GY9 5 CP81 cod 0505A005 LAMP 300W 230V GY9 5 M38 cod 0505A032 Gel filters 5 PROFILO COMPACT 2 IMPORTANT SAFETY INFORMATIONS 2 1 Fire prevention PROFILO Compact halogen uses a GY9 5 300W lamp Never locate the fixture on any flammable surface Minimum distance from flammable materials 1 MT Minimum distance from the closest illuminable surface 1 MT Connect the projector to mains power via a thermal magnetic circuit breaker 2 2 Prevention of electric shock High voltage is present inside the unit Unplug the unit prior to performing any function which involves touching the inside of the projector including lamp replacement The level of technology present in the PROFILO Compact requires the assistance of specialised personnel for all servicing Please refer to an authorised D T S service centre A good earth connection is essential for proper functioning of the projector Never connect the unit without proper earth
6. cated on the top front side of the unit photo 1 2 Now it is possible to move the covers for internal inspection photo 2 Photo 1 Photo 2 10 PROFILO COMPACT 9 PERIODIC CLEANING Lenses and reflectors Even a fine layer of dust can reduce the luminous output substantially Regularly clean all lenses and the reflector using a soft cotton cloth dampened with a specialist lens cleaning solution 9 1 Periodic controls Lamp The lamp should be replaced if there is any visible damage or deformation due to heat This will help to avoid the danger of the lamp explosion Mechanical parts Periodically check all mechanical parts replacing them if necessary Attention Disconnect mains power prior to removing the projector housing died Note The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein MADE IN ITALY C The Lighting Company D T S Illuminazione s r l Via Fagnano Selve 10 12 14 47843 Misano Adriatico RN Italy Tel 39 0
7. connection The fixture should be located in places with a good air ventilation Never look directly into the lamp when itis on 2 4 Safety The projector should always be installed with bolts clamps and other tools that are capable of supporting the weight of the unit Always use a second safety cable to sustain the weight of the unit in case of the failure of the main fixing point The external surface of the unit at various points may exceed 150 C Never handle the unit until at least 15 minutes have elapsed since the lamp was turned off Always replace the lamp if any physical damage is evident Never install the fixture in an enclosed area lacking sufficient air flow The ambient temperature should not exceed 35 C A hot lamp may explode so always wait for at least 15 minutes prior to attempting to replace the lamp Always wear Suitable hand protection when handling the lamp 2 5 Level of protection against the penetration of solid and liquid matter The projector is classified as an ordinary appliance and its protection level against the penetration of solid and liquid matter is IP 20 3 MOUNTING THE LAMP Warning Switch off the unit before replacing the lamp Lamp CP81 GY9 5 300W 230 240V 6900 LM 3200 K Life time 150 hours M38 GY9 5 300W 230 240V 5500 LM 2900 K Life time 2000 hours 6 PROFILO COMPACT 1 Loose the screw and the knob located on the top back side of the unit photo 1 and 2 Photo
8. ou reproduit dans sa totalit ou partiellement sans le consentement pr alable de D T S D T S se r serve le droit d apporter toutes modifications et am liorations esth tiques fonctionnelles ou de design sans pr avis chacun de ses produits D T S d cline toute responsabilit sur l utilisation ou sur l application des produits ou des circuits d crits Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y controladas Con todo no se asume ninguna responsabilidad por eventuales inexactitudes Todos los derechos han sido reservados y este documento no puede ser copiado fotocopiado o reproducido total o parcialmente sin previa autorizaci nescrita de D T S D T S se reserva el derecho a aportar sin previo aviso cambios y modificaciones de car cter est tico funcional o de dise o a cada producto suyo D T S no se asume responsabilidad de ning n tipo sobre la utilizaci n o sobre la aplicaci n de los productos o de los circuitos descritos INDICE Technical features Important Safety informations Mounting the lamp Voltage and frequency Installation Mains connection Projector use Open the unit Periodic cleaning PROFILO COMPACT page 4 page 5 page 5 page 6 page 6 page 7 page 7 page 9 page 10 MADE IN ITALY C 1 TECHNICAL FEATURES Voltage 230V 50 60 Hz Lamp socket Gy9 5 300 W halogen lamp IP grade protection IP20 Steel boby with aluminium parts 2 lenses opti

Download Pdf Manuals

image

Related Search

Manual manual manualslib manual car manuale digitale manually meaning manual timesheet manual transmission manual wheelchair manual arts high school manually update your device drivers windows manual definition manual for courts martial manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manual transfer switch manualidades manual blood pressure cuff manual handling manual transmission cars for sale manual digital manual pdf manual autopilot enrollment

Related Contents

MANDO DISTANCIA MANUAL DEL USUARIO/A SERIE  Guida a Kubuntu sul desktop  Gestão de Manutenção do Equipamento  The instruction should be thoroughly read prior to use - A-Link  Cross-platform graphics with cairo  Pages from Office Pro 24 Service Manual for Units  AOR `DWD 0DVWHU User`s Manual    Accessoire pour machine à pâtes NC-2715  EN / RPBA-01 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file