Home
M6 User mannual
Contents
1. N 13412345678 GP V CG REG S CSQ B AO T1 AF T2 CS H TH 00 GPS N ER gt We use to divide each part use lt gt to stands for the head and the tail BSJ stands for the fixed format head T TCP IP and port U UDP IP and port A stands for the APN parameter such as CMNET N stands for the terminal No such as 13800000000 GP stands for whether online V OK stands for online V NO stands for offline CGREG stands for GPRS register status S 1 or 5 stands for registered CSQ stands for the signal intensity B 0 31 31 the strongest signal 99 n signal AO stands for fixed time upload position data s time interval when ACC open T1 3 65535 unit second AF stands for fixed time upload position data s time interval when ACC close T2 1 255 unit minute CS stands for over speed threshold H 0 255 Unit km h TH stands for call limit GPS stands for receiving satellite numbers N 0 16 ER stands for the last error code of the car terminal SMS function 1 Mobile phone to locate the position You can editor SMS position to the terminal LY 800 the terminal LY 800 will send the longitude latitude of that position to your mobile phone The second way that you can send SMS map to LY 800 it will reply the longitude latitude of google link to your mobile 2 Control oil way You can send SMS stopoil to LY 800 the LY 800 will cut off the oil way of your vehicles You can send SMS supplyoil to LY 800 the it will supp
2. red line of the terminal would connect with the alarm speaker or buzzer When set to CAROFF it can activate the oil way it means the monitoring center would send cut off the oil instructions it would use terminal to control the output signal to cut off the oil way of the car 11 Short message debugging ways settings In order to take easy way to debug the terminal and testing the terminal s working state the terminal increase the short message debugging instructions When you using text messages to read parameters you don t need not to input password but if you want to change the machine parameters you have to input the correct password Control 1 Remote restart When the monitoring center remote send the restart instructions the terminal will automatically cut off the power and to restart The directive is mainly used for communications in normal condition and other abnormal condition it would cut off the power of terminal and restart In order to ensure the terminal can work normally After restart the terminal the mileage statistics will reset 2 Remote controlling oil This function mainly divided into cut off the oil and supply the oil The monitoring center allots stop oil instructions terminal will directly cut off the oil of the vehicles the car will shut down The monitoring center send the supply oil instructions the terminal will supply the oil of the vehicles 3 Driving mileage initialization Set the
3. 0 34 Port 11001 The server UDPIP is 219 123 10 34 Port 6788 Public network APN CMNET If you set the terminal number to 13412345678 the SMS as followed lt SPBSuJ P BSJGPS T 219 133 034 198 6690 U 219 133 034 198 6688 A CMNET N 1 3412345678 gt But sometimes some monitoring center server s software only support UDP then you can set the terminal like this The server UDPIP is 219 123 10 34 Port 6788 Public network APN CMNET If you set the terminal number to 13412345678 the SMS as followed lt SPBSJ P BSJGPS T 219 133 034 198 6690 U 219 133 034 198 6688 A CMNET N 1 3412345678 gt At this time the car terminal receive the data by TCP UDP method 3 Platform setting and recording specification LY 800 material recording as followed Vehicles No 12312312 The terminal No 13512312312 SIM card No 13512312312 Note You should set the terminal No 13512312312 the same as N you set by SMS lt SPBSJ P BSJGPS T 219 133 034 198 6690 U 219 133 034 198 6688 A CMNET N 1 3512312312 gt After you input the material to the platform you can named the vehicles by the C S version to see if the terminal will return data 5 The terminal working status query and normal fault specification 1 Check or return SMS parameter When you set the terminal parameter or use SMS to check terminal parameter the terminal will return good configuration parameter information Format lt BSJ T XxXx XXX XXX XXxX pppp U yyy yyy yyy yyy uuuu A apn
4. LY 800 User mannual Contents Query function 1 Check position 2 parameter status query 3 Version query Settings 1 Regular scheduled times return settings 2 Regular time return location information s time interval settings 3 Overspeed alarm threshold settings 4 Parking overtime alarm threshold settings 5 Electronic fence settings 6 IP and port settings 8 Modify the SMS center number settings 9 TCP heartbeat interval settings 10 Main engine output control mode settings 11 Message debug mode settings Control 1 Remote reset and restart settings 2 Remote control oil 3 Driving mileage initialization 4 Sending and receiving dispatching information and extension instruction 5 Remote upgrade software Alarm 1 Over speed alarm 2 Parking overtime alarm 3 GPS antenna open circuit alarm 4 Car battery power cut off alarm 5 Custom alarm high and low sensor alarm 6 Robbery SOS alarm 7 Drive in and out of the fence alarm Others 13 Mileage statistics 14 Blind area added upload the information Query function 1 Position query After received position query instructions the terminal would returns the current position of the vehicle information Location information include time latitude longitude speed position orientation marks vehicles and terminal state etc 2 Parameters status query After received the parameter states query instructions the terminal would return to the current sta
5. arm way When the fist alarm it would upload a message The rest alarm wold according to the scheduled resending time s interval to upload the message Cancel alarm way Send the cancelling alarm instructions and the car s running speed is greater than 0 Send the cancelling alarm instructions and close the parking overtime alarm 3 GPS antenna short circuit alarm GPS antenna state signs are included in the location informations According to the time interval to upload it 4 Terminal power off alarm Power off alarm status symbol included in power in the location information According to the time interval upload it 5 Custom alarm high and low sensor alarm This type of terminal support 1 road low and 1 road high sensor Sensor alarm status signs included in the location information According to the time interval upload it 6 Robbery SOS alarm Rob SOS alarm sign a included in the position in the information When you press the alarm button above 0 5 seconds such as in robbery SOS alarm conditions it would alarm If you under the alarm condition it would cancel the alarm When it alarms the button s light stays on when cancel the alarm the button s light off Alarm way When the fist alarm it would upload a message It is according to time interval to upload the message Cancel alarm way The monitoring center send the calcelling alarm instructions 7 Geo fence alarm After you set up the Geo fence when you run in an
6. cation time interval according to the car power on and off seperately Note When the car power on the time interval of the return location information s minimum unit is 3 seconds 3 Over speed alarm threshold settings After you set up the over speed alarm s threshold if the vehicles speed is gt the threshold valve and the time would stays for 10 seconds it will alarm The factory default for closed terminals i e set value 0 Set the value is more than 10 km h is valid 4 Parking overtime alarm valve setting After set up the parking overtime alarm valve when the car s speed is 0 and the time stays or greater than the overtime alarm valve it would alarm When you set up the overtime alarm valve you must set the valve more than 1 seconds is valid The factory default for closed terminals i e set value 0 5 Electronic fence Settings Terminal support maximum 50 electronic fence with a range of rectangular fence When you drive in and out of the fence the terminal will upload a hint When the terminal issued the line node to the appointed vehicles it would restrict the vehicles only can drive in the permitted line range At present it only support 1 line node 6 IP and port setting The monitoring center can change the terminal IP number and port number at any time After you change the terminal the new IP and port number would take effect immediately After you changed the IP port the terminal would reply respo
7. d out of the fence the terminal would upload a hint information Alarm way Triggered alarm Other 1 Mileage statistics The in all moving position of GPS the unit is m The maximum is 16777215 meters When it achieve to maximum value it would re caculate the statistics from 0 Statistical conditions The vehicles power on and the GPS effective positioning 2 Blind area When the vehicles in GPRS signal blind area the terminal will automatically save the location data according to schedule resending time When the car power on after the vehicles received the GPRS signal the terminal would automatically send the saved datas that in blind area to the monitoring center it can save 1500 datas at most 5 SMS or platform remote inquires the terminal parameters You can check the terminals parameter configuration through SMS or GPRS instrucitons These parameter configurations include parameters of the terminal such as TCP UDP the terminal code resending time APN Error record etc LY 800 setting method specification LY 800 setting method GPRS UDP or TCP UDP 1 The host device 2 The host device wire diagram Two orange wires are the emergency button wire dark green wire is the custom high trigger wire brown wire is the custom low trigger purple wire is the stop oil wire The red wire is the power black wire is ground wire white wire is ACC checking wi
8. designated vehicles mileage Miles 3 bytes show HEX the unit is meters range 0 0 xFFFFFF x000000 such as 0 stands for 0 x000000 4 Sending and receiving dispatching information and extension instructions The monitoring center would send the dispatching text information or extension instructions to the terminal This information send as ASCALL code or BG2312 code the content of the short message would not exceed 240 bytes 5 Supports remote software upgrade Manufacturer shall be in accordance with the operating Alarm 1 Overspeed alarm witnesses settings After you set up the over speed alarm s threshold value if the vehicles speed is greater than 10km h and the time would stays for 10 seconds it would alarm The overspeed signs are inclued in the location informations Alarm way When the first alarm it would upload a message The rest alarm would according to the scheduled time resending time s interval to upload the message Cancel alarm way You should send the cancelling alarm instructions to the terminal and the vehicles running speed is smaller than overspeed alarm witnesses value Send the cancelling overspeed instructions and close the overspeed alarm 2 Parking overtime alarm valve setting After set up the parking overtime alarm valve when the car s speed is 0 and the time stays or greater than the overtime alarm valve it would alarm Parking overtime s sign is inluded in the location infomations Al
9. her the SIM card have enough telephone charge or whether you open the GPRS service and check if you set the wrong IP and port GSM module broken the light tube broken lights keeps go out Suggest return the terminal to factory for repairing No signal can t read the SIM card lights keeps go on Solution Do not truck loading in the blind area or change another SIM card If these methods are not OK you can return the terminal to factory for repairing Set online status SMS settings 2 The terminal SMS setting online instruction specification You can use any telephone to send the configuration instruction to the terminal and the instruction specification as followed lt SPBSuJ P BSJGPS T 219 133 034 198 6690 U 219 133 034 198 6688 A CMNET N 13 412345678 gt We use to divide each parts use lt gt to stands for the head and the tail SPBSJ stands for the fixed format head P stands for the password different manufacturer use different password 6 byte length T TCP IP and por xxx xxx xxx xxx stands for IP if there aren t 3 numbers you should add 0 before the number such as 219 011 073 255 stands for 219 011 073 255 pppp stands for port the maximum is 65535 such as 1100 When you set the port to 0 stands for the terminal do not use TCP U UDP IP and port the format as the TCP format A stands for APN parameter such as CMNET N stands for the terminal number such as 13800000000 The server TCPIP is 219 123 1
10. ly the oil of your vehicles 3 Control circuit You can send SMS stopele to LY 800 LY 800 will cut off the circuit of your vehicle You can send SMS supplyele to LY 800 it will supply the circuit of your vehicle 4 Over speed alarm Set over speed Send SMS speed space 080 to LY 800 LY 800 will default the over speed value as 80km h Cancel over speed Send SMS nospeed to cancel over speed 5 Restart the terminal You can send SMS restart to LY 800 the terminal will restarted 6 Set ACC ON Set ACC ON Send SMS ACC ON space 0120 to LY 800 LY 800 will default ACC time as 120s Set ACC OFF Send SMS ACC OFF space 0150 to LY 800 LY 800 will default ACC time as 150s 7 Change the time zone The terminal factory time zone is zone 8 if you want to change to your local time zone pls editor SMS zone space local time zone to send to LY 800 then LY 800 will return SMS zone is ok that means you set time zone successfully For example Berlin is East area so the SMS is 1 SMS zone 1 this is stands for Berlin s time zone USA is West area so the SMS is zone 5 Such as East time zone 1 2 3 4 5 West time zone 1 2 3 4 5 8 When the vehicle is over speed LY 800 will send over speed alarm SMS overspeed to LY 800 If you ve set 5 administrator numbers LY 800 will send this SMS to your 5 administrator numbers
11. nse information to the original IP port and rebuild connection request to the new IP port at the same time When the terminal send the TCP connection to the monitoring center it would discard not close the original connection the connection of monitoring center is still exist So the monitoring center GPRS server also need to check whether there is repeatedly connecting if there is repeatedly connecting you need to clear the terminal s original connecting otherwise the GPS server can t bear it because of opening too much linkage 8 TCP heartbeat interval setting When you set designated vehicles according to set time upload the location information this position information would use TCP to upload the information this instruction main as TCP heartbeat instructions Host default for 3 minutes This parameter would not lost when the power off After the establishment of the TCP connection by mobile router keep period of time if the TCP transmission interval is too long the terminal would not reserve the connection the terminal only can resend the connection to the center 9 The host terminal output control mode settings Set the output control mode There are two ways oil control mode and the speed control hint mode the terminal default oil way StrValu the setting value is Ascall code no fixed length When set to CARON it can activate the overspeeding hint way when the overspeed alarm open it would output the signal hint The
12. re 3 Debug procedure 1 Install wire connection 2 The terminal set IP Port terminal No SMS setting 3 The monitoring center record vehicle s materials 4 Testing the detailed function 4 Procedure detailed specification 1 The device wire connection specification Two orange wires are the emergency button wire dark green wire is the custom high trigger wire brown wire is the custom low trigger purple wire is the stop oil wire The red wire is the power black wire is ground wire white wire is ACC checking wiree Status lights specification LY 800 model have two lights beside the terminal GPS yellow light and GSM red light GPS yellow light Effective positioning 0 5 seconds light on off light quick flashing Invalid positioning one seconds light on off light slow flashing Reasons waked GPS signal didn t search the satellite signal antenna un connected the signal lights keep lighting Solution check whether GPS antenna covered by some metal objects whether the copper coil of the port break off GPS module broken the lights keeps lighting off Reasons The lights tube broken GPS module broken suggest return the terminal to factory for repairing GSM light red GPRS connect to the center successfully 0 5 seconds light on off light flashing quickly SIM card register GPRS failed one seconds light on off light flashing slowly Solution Check whet
13. te of the vehicle information State information include position information vehicle state terminal state set parameters mileages etc 3 Version query After received the version query instructions the terminal would return the current version of vehicle information Version query include terminal model terminal chip types software version software release time Settings 1 Fixed time set times to return position information settings Set designated vehicles according to the fixed time times to send the location information to the center through UDP This instruction request the terminal use interval as the time interval return location information up to 65535 times positioning information 2 Fixed time return location information s time interval settings This settings include return the location information s time interval when the car power on and off When the car power on the time interval of the return location information the factory default is 30 seconds When the car power off the time interval of the return location information the factory default is 0 seconds If the car power off the return location information s time interval is 0 seconds whatever the car is power on and off the return location information s time interval according to the car power on s time interval If the car power off the return location information s time interval gt o seconds the terminal would return the lo