Home

MICROMAPPER™ - Fluke testery

image

Contents

1. FLUKE networks LAN Wiremap Checker Users Manual English November 2001 Rev 2 9 03 2001 2003 Fluke Corporation All rights reserved All product names are trademarks of their respective companies LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke Networks product is warranted to be free from defects in material and workmanship under normal use and service The warranty period is one year and begins on the date of purchase Parts accessories product repairs and services are warranted for 90 days This war ranty extends only to the original buyer or end user customer of a Fluke Networks authorized reseller and does not apply to disposable batteries cable connector tabs cable insulation displacement connectors or to any product which in Fluke Networks opinion has been misused altered neglected contaminated or damaged by accident or abnormal conditions of operation or handling Fluke Networks war rants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly re corded on non defective media Fluke Networks does not warrant that software will be error free or operate without interruption Fluke Networks authorized resellers shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of Fluke Networks Warranty support is av
2. Mapper Users Manual i Introduction Congratulations on your purchase of the MicROMApPPER network cable tester The MICROMAPPER is a hand held cable tester that enables network professionals to quickly and easily verify the integrity of Ethernet twisted pair cables In one step the MiCROMAPPER will test twisted pair cabling for opens shorts reversed crossed and split pairs Simply slide the switch to the Cable position press the TEST button and the MicroMAPPER will automatically scan for any existing faults in your cable The specially designed remote unit is provided for one person testing of installed cabling The tone generator function can be used with the MicroProbe cable tracer to trace cables and locate cables hidden in ceilings walls floors and bundles MICROMAPPER M MicroMapper User s Manual Features Tests for wiring faults and detects opens shorts crossed reversed and split pairs Split pair fault detection requires a minimum cable length of 15 75 40cm e Verifies shield integrity e MICROMAPPER s Remote Identifier enables one person to test installed cabling Easy to read fault display and high speed testing e Generation of two tones for tracing cables and locating hidden cables Debug mode for detailed fault identification results e Auto sleep mode to decrease power consumption MiCROMAPPER Kit Content Your MICROMAPPER kit contains the following e 1 MICROMAPPER
3. R e REVERSED TI 1 2 3 6 4 5 7 8 S TEST REVERSED TEST MISWIRE MISWIRE SPLIT PAIRS 6 SPLIT PAIRS 6 LOW BATTERY LOW BATTERY 6 1 2 3 6 4 5 7 8 S MicroMapper User s Manual REVERSED SPLIT PAIR 1 2 3 6 4 5 7 8 SHIELD a TONER e 1 2 3 6 4 5 7 8 SHIELD 0 a TONER SHORT e SHORT TEST REVERSED TEST REVERSED MISWIRE MISWIRE SPLIT PAIRS SPLIT PAIRS LOW BATTERY LOW BATTERY 1 2 3 6 4 5 7 8 S MIS WIRE 1 2 3 6 4 5 7 8 SHIELD a TONER o SHORT e TEST REVERSED 6 MISWIRE SPLIT PAIRS LOW BATTERY 6 UA Ah Technical Specifications Connectors MicROMAPPER main unit RJ45 jack Remote Identifier RJ 45 jack Pairs tested 1 2 3 6 4 5 7 8 and shield LED Display Horizontal 5 green LEDs for pairs and shield display 1 2 3 6 4 5 7 8 and SHIELD Vertical 6 red LEDs TONER SHORT REVERSED MISWIRE SPLIT PAIRS and LOW BATTERY Cables test limit Minimum 15 75 40cm Maximum 656 200 m MicroMapper Power IEC 86 1 1996 07 Primary Batteries General IEC 60086 2 1997 07 Primary Batteries Specification Sheets MICROMAPPER requires four 1 5 AAA batteries LRO3 Others AAA E92 4003 JIS AM 4 ANSI 24A 1 5 Volt nominal Remote Identifier No battery required Dimensions MICROMAPPER 4 92 x 2 05 x 1 54 1 125 mm x 52 mm x 39 mm Remote I
4. ailable only if product is purchased through a Fluke Networks authorized sales outlet or Buyer has paid the applicable international price Fluke Networks reserves the right to invoice Buyer for importation costs of repair replacement parts when product purchased in one country is submitted for repair in another country Fluke Networks warranty obligation is limited at Fluke Networks option to refund of the purchase price free of charge repair or replace ment of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke Net works assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepaid FOB Destination If Fluke Networks determines that failure was caused by neglect misuse contamination alteration accident or abnormal condition of operation or handling or normal wear and tear of mechanical components Fluke Networks will provide an estimate of repair costs and obtain authorization before commencing the work Following repair the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportatio
5. dentifier 1 87 x 1 12 x 0 87 47mm x 28mm x 22mm Weight with Remote Identifier 125 g MicroMapper Users Manual 10
6. ear the cable under test 6 Slide the switch on the right side to the Off position to discontinue the tone Always power the unit off to prevent battery drain MicroMapper User s Manual MICROMAPPER Tests 1 Slide the switch on the right side to the Cable position to turn MICROMAPPER on Connect one end of the cable to be tested to the MiCROMAPPER s RJ45 jack Connect the other end of the cable to the Remote s RJ45 jack Press TEST to view the results The horizontal LEDs indicate the cable s integrity status e Green Pair or Shield is good e Green flashing Pair or Shield is faulty e No light Pair is open or cable is not shielded The vertical LEDs indicate the wiring faults and a low battery status Wiring faults are SHORT REVERSED MISWIRE SPLIT PAIRS To find out a fault on a specific pair use MICROMAPPER s diagnostic feature Press and hold TEST for more than 2 seconds MICROMAPPER will scan each pair and the shield pausing and flashing each green LED separately If a faulty pair is detected the corresponding fault status will blink in red Note Push the Remote Terminator onto the MicroMapper until it snaps into position This configuration allows you to conveniently test patch cables MicroMapper Fault Status Fault Status SHORT OPEN 1 2 3 6 4 5 7 8 SHIELD SHORT 1 2 3 6 4 5 7 8 SHIELD e Q a TONER e SHORT O TONE
7. n charges FOB Shipping Point THIS WARRANTY IS BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FLUKE NETWORKS SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES INCLUDING LOSS OF DATA ARISING FROM ANY CAUSE OR THEORY Since some countries or states do not allow limitation of the term of an implied warranty or exclusion or limitation of incidental or conse quential damages the limitations and exclusions of this warranty may not apply to every buyer If any provision of this Warranty is held invalid or unenforceable by a court or other decision maker of competent jurisdiction such holding will not affect the validity or enforce ability of any other provision 6 01 Fluke Networks PO Box 777 Everett WA 98206 0777 USA Table of Contents IM OU SA FO ee er MICROMAPPER KIC COMENT BESTE O QNM T unm Safety InformatOM rd een ambo abr Danger bm n abu beca Contacting Fluke NGI OURS nn ian een MICROMAPPER Controls and LEDs MICROMAPPER s Toner Operation MicroMapper TT aga dn FE Ez UU Technical Specifications 2 0 0000 0 0000000 enm men e hn nnn menn gana a aa A kabagan anakane Micro
8. network cable tester e 1 MICROMAPPER remote e Patch cord e Quick Reference Guide e Product Manuals CD Registration Registering your product with Fluke Networks gives you access to valuable information on product updates troubleshooting tips and other support services To register fill out the online registration form on the Fluke Networks website at www flukenetworks com registration If you do not have Internet access print the registration form from the CD included with the product Fill out the form then mail or fax it to the appropriate address for your country Safety Information AWarnings Do not connect MicROMAPPER to a live circuit as it may damage the unit Do not open the unit or attempt to repair in case of malfunction Please send it back to your distributor for repair or replacement Caution Strong radio frequency fields may cause inaccurate readings Do not drop or get the unit wet Do not expose MicRoMAPPER to extreme humidity or direct sunlight MicroMapper Safety Information Contacting Fluke Networks o 3 www flukenetworks com support flukenetworks com 1 425 446 4519 Australia 61 2 8850 3333 or 61 3 9329 0244 Beijing 86 10 6512 3435 Brazil 11 3044 1277 Canada 1 800 363 5853 Europe 44 1923 281 300 Hong Kong 852 2721 3228 Japan 81 3 3434 0181 Korea 82 2 539 6311 Singapore 65 6738 5655 Taiwan 886 2 227 83199 USA 1 800 283 5853 Visit o
9. ur website at www flukenetworks com for a complete list of phone numbers MicroMapper User s Manual MICROMAPPER Controls and LEDs 12 3 6 45 7 8 SHIELD TONER TEST REVERSED SHORT MISWIRE SPLIT PAIRS LOW BATTERY FLUKE MICROMAPPER FLUKE REMOTE atx02f eps Figure 1 Network Cable Tester Table 1 MicRoMAPPER Controls and LEDs Battery MICROMAPPER requires four 1 5 AAA batteries IEC LRO3 Others AAA E92 4003 JIS AM 4 ANSI 24A 1 5 Volt nominal SHORT TEST REVERSED SPLIT PAIRS LOW BATTERY atx03s bmp The Battery LED will light up when MICROMAPPER detects a low battery condition Using MICROMAPPER with a low battery may affect the test accuracy If MICROMAPPER is stored for more than a month the battery should be removed MicroMapper Battery MICROMAPPER s Toner Operation 1 Slide the switch on the right side of MicROMAPPER to the Toner position 2 Connect the cable to the MicRoMAPPER s RJ45 jack To send a tone into a patch panel connect one end of the included patch cord to the 5 RJ45 jack and the other end to a jack on the panel 3 To generate tone 1 press and quickly release the TEST button 4 To generate tone 2 press and hold the TEST button for two seconds 5 Use the MICROPROBE to trace the connected cable The signal reception is strongest n

Download Pdf Manuals

image

Related Search

Related Contents

2004 Nissan Quest Service Bulletin P1148 and P1031  Bosch 2609255201  C11440-22CU C14400-22CU01 Instruction manual  Active Harmonic Filter Installation, Operation, and  Février 2012  ーお手入れ方法  Kambrook KFP40 User's Manual    Manual CENTRAL Calefaccion v.14  Elettrosega I Electric chainsaw GB Tronçonneuse électrique F  