Home

Safety Controller Ethernet Interface Module User`s Manual (Hardware)

image

Contents

1. involving and MELCO shall not be liable for a default a liability for defect warranty a quality assurance negligence or other tort and a product liability in these applications 1 power plants 2 trains railway systems airplanes airline operations other transportation systems 3 hospitals medical care dialysis and life support facilities or equipment 4 amusement equipments 5 incineration and fuel devices 6 handling of nuclear or hazardous materials or chemicals 7 8 2 lt mining and drilling and other applications where the level of risk to human life health or property are elevated 4 Product description 4 1 Provided diagnostics data The WS0 GETH provides the following diagnostics data e input values HIGH LOW for all MELSEC WS extension modules and EFI devices connected e output values HIGH LOW for all MELSEC WS input output extension modules and EFI devices connected e logic results ethe error and status information of all modules e diagnostics system CRCs I O errors For a detailed description of the format and mapping of the diagnostics data please read the operating manuals Safety controller user s manual detailed The occurrence of random or systematic faults within the module or in its control does not impede the MELSEC WS system s safety function 4 2 Display elements The WSO GETH is equipped with four LEDs PWR voltage supply LINK ACT 1 and LINK ACT 2
2. and Module Status MS or STATUS error and status indication LED Meaning Off No power supply PWR Rights up Green Power supply on off No power supply LINK No Ethernet connection ACT 1 Rights up Ethernet connection active no data LINK Green transmission ACT 2 Flashes Ethernet connection active data Green transmission Off No power supply Power up state Rights up Green Executing live data to from CPU Hashes Idle CPU STOP reen 1 Hz Configuring configuration Seii required MS 2 Hz Critical fault gateway fault Rights up Critical fault other system module Red fault Executing but Ethernet communication not established or Flashes faulty Red Green When a closed connection is interrupted the MS LED will be this state for ten seconds PORT 1 it LED power supply green E LED network activity for wgl Ethernet port 1 or 2 green i LED MS or STATUS red green PORT 2 4 3 Connections The WSO GETH provides an integrated Ethernet switch with two RJ45 ports for connection to the Ethernet network 5 Mounting Dismantling A The MELSEC WS system is only suitable for mounting in a control cabinet with at least IP ATTENTION 54 degree of protection While supply voltage is applied gateways must not be plugged to nor be removed from the MELSEC WS system To ensure full el
3. the direction of the arrow until the side plug connection latches in gt Install the end clips on the right and left Press the module downwards at the rear 1 and remove it from the DIN rail in the direction of the arrow while keeping it pressed down 2 6 Electrical installation Do not commission without a check by specialist personnel Before the initial commissioning of the system in which you are using a MELSEC WS system it must be checked and released by qualified safety personnel The results of this check must be documented ATTENTION The WSO0 GETH can be configured using the MELSEC WS Setting and monitor tool via the Ethernet interface of the gateway or via the WSO CPUx module s RS232 interface A detailed description of the configuration can be found in the operating instructions for the MELSEC WS Gateways 7 Inthe event of faults A In the event of unclear faults cease operation ATTENTION Stop the machine if you cannot clearly identify or allocate the error and if you cannot safely rectify the malfunction Complete functional test after error rectification Carry out a full functional test after an error has been rectified 8 Technical data Supply circuits via e g MELSEC WS WS0 CPUx Supply voltage Vs 24 V DC 16 8 to 30 V DC Power consumption Max 2 4 W Interfaces Data Transmission 10MBit s 10Base T or 100MBit s Speed 100Base TX autosensing 3 Port layer 2 man
4. 486 0 Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 l 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Country Region Sales office Tel China Taiwan Korea Singapore Thailand Indonesia India Australia Mitsubishi Electric Automation China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2480 Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kanna
5. 5to95 RH 5to95 RH humidity Storage ambient 25t070 C 25to75 C 40 to 75 C temperature Storage ambient 10 to 95 RH 5to95 RH 5to95 RH humidity 1 When the WS0 GCC100202 is included in the system operating ambient temperature will be 0 to 55 C e EMC standards that are applicable to the products differ MELSEC Q bide aaa MELSEC QS EMC standards EN61000 6 2 EN55011 EN61131 2 1 About this document 1 1 Documentations for the MELSEC WS system These manuals apply for the MELSEC WS Ethernet interface module and only in combination with the corresponding user s manual Safety Controller Ethernet Interface Module User s Manual The installation configuration and commissioning of the MELSEC WS safety control system are described in the Safety Controller User s Manual and Safety Controller Setting and Monitoring Tool Operating Manual Title Number Safety Controller User s Manual hee Safety Controller Ethernet Interface User s WS ET U E Manual 13JZ33 Safety Controller CC Link Interface User s WS CC U E Manual 13JZ45 Safety Controller Setting and Monitoring SW1DNNWSOADR B O E Tool Operating Manual 13JU67 In addition mounting protective devices also requires specific technical skills which are not detailed in this documentation 2 Correct use A Do not use data from a MELSEC WS Ethernet Teraa ATTENTION interface module for s
6. MITSUBISHI WS0 GETH00200 Safety Controller Ethernet Interface Module User s Manual Hardware Mitsubishi Electric Corporation 2 7 3 Marunouchi Chiyoda ku Tokyo Japan Mitsubishi Electric Europe BV Gothaer strase 8 40880 Ratingen Germany All rights reserved Specified product properties and technical data do not represent a guarantee declaration MODEL WS ET U HW MODEL CODE 13J203 IB NA 0800446 C 1108 MEE 2009 MITSUBISHI ELECTRIC CORPORATION Precautions regarding warranty and specifications MELSEC WS series products are jointly developed and manufactured by Mitsubishi and SICK AG Industrial Safety Systems in Germany Note that there are some precautions regarding warranty and specifications of MELSEC WS series products lt Warranty gt e The gratis warranty term of the product shall be for one 1 year after the date of delivery or for eighteen 18 months after manufacturing whichever is less e The onerous repair term after discontinuation of production shall be for four 4 years e Mitsubishi shall mainly replace the product that needs a repair e It may take some time to respond to the problem or repair the product depending on the condition and timing lt Specifications gt e General specifications of the products differ MELSEC WS MELSEC Q MELSEC QS Operating ambient ona 55 C 0 to 55 C 0 to 55 C temperature Operating ambient 10to95 RH
7. afety related application These gateways only generate non safety related data which are not suitable for use in safety related applications The WS0 GETH is an Ethernet based gateway and a part of the MELSEC WS system that communicates with primary control systems It provides non safe fieldbus data for control and diag nostic purposes The gateway does not have its own power supply and can only be operated with a MELSEC WS system Up to two gateways can be used in a MELSEC WS system These must be installed directly to the right of the WS0 CPUx This gateway must be used only by qualified safety personnel and only on the machine where it has been installed and initialized by qualified safety personnel in accordance with the operating manuals A Observe the protective notes and measures in the ATTENTION MELSEC WS User s manual Mitsubishi Electric Co accepts no claims for liability if the equipment is used in any other way or if modifications are made to the device even in the context of mounting and installation e When mounting installing and using the MELSEC WS system observe the standards and directives applicable in your country e The national international rules and regulations apply to the installation use and periodic technical inspection of the MELSEC WS system in particular EMC Directive 2004 108 EC Provision and Use of Work Equipment Directive 89 655 EWG Work safety regulations safety rules
8. aged switch with Auto MDI X for automatic detection of crossed Ethernet cable Integrated switch Connection 2 x RJ45 ports technology IP address 192 168 250 250 Address factory Subnet mask 255 255 0 0 setting Default gateway 0 0 0 0 Data interface Backplane bus FLEXBUS See Safety controller Ethernet interface Wir rameter f e Parameters module user s manual Diagnostics data format See Safety controller Ethernet interface module user s manual General specification Ambient operating 25 C to 55 C temperature Storage o o temperature 25 C to 70 C Humidity 10 to 95 non condensing Climatic conditions EN 61131 2 55 C 95 rel humidity in accordance with No corrosive gases estan ene Tested in accrordance with EN61131 2 Rigidity Electromagnetic IEC 61000 6 2 EN 55011 Class A compatibility Weight without 125g packaging Country Region Sales office Tel U S A Brazil Germany U K Italy Spain France South Africa Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102
9. e These manuals and the related operating manuals must be made available to the user of the machine where a MELSEC WS system is installed The machine operator is to be instructed in the use of the device by qualified safety personnel and must be instructed to read the operating manuals e If Ethernet gateway GETH is used the CPU module is intended to be used with a Class 2 power source or Class 2 transformer in accordance with UL1310 or UL1585 because the Ethernet gateway is powered from the CPU module 2 1 Disposal Disposal of unusable or irreparable devices should always occur in accordance with the applicable country specific waste disposal regulations e g European Waste Code 16 02 14 3 Conditions of use for the product 1 Although MELCO has obtained the certification for Product s compliance to the international safety standards IEC 61508 EN 954 1 ISO 13849 1 from TUV Rheinland this fact does not guarantee that Product will be free from any malfunction or failure The user of this Product shall comply with any and all applicable safety standard regulation or law and take appropriate safety measures for the system in which the Product is installed or used and shall take the second or third safety measures other than the Product MELCO is not liable for damages that could have been prevented by compliance with any applicable safety standard regulation or law MELCO prohibits the use of Products with or in any application
10. ectromagnetic compatibility EMC the DIN mounting rail must be connected to functional earth FE 5 1 Steps for mounting the modules e Mounting in accordance with EN 50274 e The modules are located in a 22 5 mm wide modular system for 35 mm DIN rails to EN 60715 e Ina MELSEC WS system the CPU module WS0 CPUO or WS0 CPU1 is positioned at the extreme left the two optional gateways follow directly Only then do the expansion modules follow The relays modules WSO 4RO have to be mounted at the extreme right e The connection between the modules is effected by means of the plug connection integrated in the housing e Ensure that suitable ESD protective measures are also taken during mounting Otherwise the FLEXBUS bus may be damaged 5 2 Steps for dismantling the modules Remove the plug in package terminals with wiring and the end clips gt If there are several modules slide the modules away from each other individually in the direction of the arrow until the side plug connection is separated 3 Make sure that the voltage supply of the MELSEC WS system is switched off Hang the device onto the DIN rail 1 Ensure that the earthing spring contact 2 contacts the DIN rail such that it can electrically conduct gt Latch the module onto the DIN rail by pressing it lightly in the direction of the arrow 3 gt Slide the modules together individually in
11. yao Bangkok 10230 Thailand Tel 66 2 517 1326 P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M 1 D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 8 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN IAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice SICK sickac http www sick com