Home
Display - Siemens
Contents
1. User Manual SIEMENS Edition January 2013 Siemens offers simulation software to plan simulate and optimize plants and machines The simulation and optimization results are only non binding suggestions for the user The quality of the simulation and optimizing results depend on the correctness and the completeness of the input data Therefore the input data and the results have to be validated by the user Trademarks SIMIT is a registered trademark of Siemens AG in Germany and in other contries Other names used in this document can be trademarks the use of which by third parties for their own purposes could violate the rights of the owners Copyright Siemens AG 2013 All rights reserved Exclusion of Liability The reproduction transmission or use of this document or ist We have checked that the contents of this document contents is not permitted without express written authority correspond to the hardware and software described However Offenders will be liable for damages All rights including rights deviations cannot be entirely excluded and we do not created by patent grant or registration of a utility model or guarantee complete conformance The information contained design are reserved in this document is however reviewed regularly and any Siemens AG necessary changes will be included in the next edition We Industry Sector welcome suggestions for improvement Industry Automation Division Process Automat
2. Copyright Siemens AG 2013 Process Automation Page 8
3. you see its editor The properties view see Figure 3 4 is used to define properties as follows 3 4 Cycle Here you can define the cycle the gateway will use for data exchange Use the project manager to assign absolute values to the eight available cycles throughout the project The default value for cycle 2 is 100ms For further detail concerning a gateways data exchange please see the general SIMIT gateway manual Mnemonic Here you can choose between international Q and German E A syntax of inputs and outputs CPU Slot Please provide the slot number of your SIMATIC CPU here Access Mode Choose here whether to use MPI cable or adapter or IP Ethernet as access mode MPI Address IP Address Please provide your SIMATIC CPU s MPI number or IP address here PRODAVE Property Value Cycle 2 Mnemonic 1 Q CPU Slot 2 Access mode MPI af MPI Address 2 Figure 3 4 Properties of a PRODAVE gateway Importing the symbol table When importing a symbol table you can decide how signals should be handled that exist in the gateway already There are three alternatives available New All signals that exist in the gateway already are removed The gateway is newly built based on the imported symbol table Add If a signal has a symbolic name specified in the imported symbol table but has no symbol name in the gateway yet it is assigned the symbol name as specified in the symbol table Symbol names that exist in the
4. 3 2 Configuring I O signals in the PRODAVE gateway The input and output signals of the PRODAVE gateway can be edited manually in the editor or can be configured by importing a symbol table from your SIMATIC project see Figure 3 3 PRODAVE ears w Inputs Reset Filter Default Symbol Name StaircaseButtonFloor0 StaircaseButtonFloor1 StaircaseButtonFloor2 StaircaseButtonFloor3 StaircaseButtonFloor4 Mainswitch Reset w Outputs Reset Filter Symbol Name StaircaseIndicatorFloor0 StaircaselndicatorFloori StaircaselndicatorFloor2 StaircaselndicatorFloor3 StaircaselndicatorFloor4 InOperation Figure 3 3 Copyright Siemens AG 2013 Process Automation Address Y 132 0 132 1 132 2 132 3 132 4 132 5 132 7 Address Y 032 0 032 1 032 2 032 3 032 4 032 5 Data Type BOOL BOOL BOOL BOOL BOOL BOOL BOOL Data Type BOOL BOOL BOOL BOOL BOOL BOOL Comment 7 lt vv Ruf Treppenhaus EG Ruf Treppenhaus 1 0G Ruf Treppenhaus 2 0G Ruf Treppenhaus 3 0G Ruf Treppenhaus 4 0G Betrieb Ein Reset Taster Comment ha 4 Rueckmeldung Treppenhaus Ruf EG Rueckmeldung Treppenhaus Ruf 1 0G Rueckmeldung Treppenhaus Ruf 2 0G Rueckmeldung Treppenhaus Ruf 3 0G Rueckmeldung Treppenhaus Ruf 4 0G Rueckmeldung Betrieb Configuring the PRODAVE gateway SIMIT 7 PRODAVE Gateway Page 5 SIEMENS Configuring the PRODAVE gateway 3 3 Properties of the PRODAVE gateway When the gateway is opened
5. Figure 3 6 shows the gateway after import using the option New Symbol Name Address Data Type Symbol_10 0 10 0 BOOL Symbol_10 1 10 1 BOOL Symbol_I10 0 110 0 BOOL Symbol_Iw2 IW2 WORD Symbol_IW14 IW14 WORD Figure 3 6 Signals after import using option New Figure 3 7 shows the gateway after import using the option Add Signals IW2 and 110 0 were not taken since they overlap with IB2 and IW10 respectively Copyright Siemens AG 2013 SIMIT 7 PRODAVE Gateway Process Automation Page 7 SIEMENS Symbol Name Symbol_10 0 S 10 1 S_IB4 S_IW12 Symbol_IW14 Figure 3 7 Address 10 0 10 1 IB2 IB4 IW10 IW12 IW14 Configuring the PRODAVE gateway Data Type y v BOOL BOOL BYTE BYTE WORD WORD WORD Signals after import using option Add Figure 3 8 shows the gateway after import using the option Replace Signals IB2 and IW10 were removed and were replaced by overlapping signals IW2 and 110 0 Symbol Name Address Data Type Symbol_10 0 10 0 BOOL Symbol_10 1 10 1 BOOL Symbol_IW2 IW2 WORD S_IB4 IB4 BYTE Symbol_I10 0 110 0 BOOL S_IW12 IW12 WORD Symbol_IW14 IW14 WORD Figure 3 8 Signals after import using option Replace NOTE gt In contrast to input signals overlapping output signals are allowed However when importing a symbol table overlapping signals are treated equally no matter whether input or output signals are concerned SIMIT 7 PRODAVE Gateway
6. T gateways is required as described in the SIMIT gateways manual Since PRODAVE is one of SIMITs SIMATIC gateways you also need to know the common aspects of all SIMATIC gateways as described in the SIMIT gateways manual 1 2 Content Chapter 2 shows how the PRODAVE gateway works and chapter 3 shows how a PRODAVE gateway is configured 1 3 Symbols Particularly important information is highlighted in the text as follows NOTE gt Notes contain important supplementary information about the documentation contents They also highlight those properties of the system or operator input to which we want to draw particular attention CAUTION AN This means that the system will not respond as described if the specified precautionary measures are not applied WARNING This means that the system may suffer irreparable damage or that data may be lost if the relevant precautionary measures are not applied Copyright Siemens AG 2013 SIMIT 7 PRODAVE Gateway Process Automation Page 1 SIEMENS Functioning of the PRODAVE gateway 2 FUNCTIONING OF THE PRODAVE GATEWAY You can use the PRODAVE gateway to write and read inputs and outputs within the process image of SIMATIC control with SIMIT You can link the PRODAVE gateway to a SIMATIC controller using the MPI interface If your controller supports Ethernet connections you may also link via Ethernet which provides higher performance than the MPI inte
7. gateway already are not overwritten Copyright Siemens AG 2013 SIMIT 7 PRODAVE Gateway Process Automation Page 6 SIEMENS Configuring the PRODAVE gateway If there is a signal in the imported symbol table that overlaps with signals that exist in the gateway already because they share an address range it will be ignored There is no merging or splitting of signals A signal is added to the gateways signals only if there is no overlap with existing signals e Replace If a signal exists in the gateway already and has a symbolic name specified in the imported symbol table it is assigned the symbol name as specified in the symbol table even if it had a symbol name assigned in the gateway already If there is a signal in the imported symbol table that overlaps with signals that exist in the gateway already because they share an address range it will be taken into the gateway configuration and all overlapping signals will be removed To show these procedures assume a gateway exists with signals as specified in Figure 3 5 Symbol Name Address Data Type 10 0 BOOL S_10 1 10 1 BOOL IB2 BYTE S_IB4 IB4 BYTE IW10 WORD S_IW12 IW12 WORD Figure 3 5 Example for gateway signals The imported symbol table contains the following signals Symbol 10 0 10 0 Symbol 10 1 10 1 Symbol T10 0 110 0 Symbol IW2 IW2 Symbol IW14 IW14 Importing this symbol table yields different results depending on the option chosen
8. ion Siemens AG 2013 SIMIT HB V7Prodave 2013 01 en Subject to change withour prior notice SIEMENS Contents 1 PREFACE 1 1 Target Group 1 2 Content 1 3 Symbols 2 FUNCTIONING OF THE PRODAVE GATEWAY 3 CONFIGURING THE PRODAVE GATEWAY 3 1 Creating a PRODAVE gateway 3 2 Configuring I O signals in the PRODAVE gateway 3 3 Properties of the PRODAVE gateway 3 4 Importing the symbol table OO oOo a BR fF SIMIT 7 PRODAVE Gateway Copyright Siemens AG 2013 Process Automation Page SIEMENS List of Figures Figure 2 1 Functioning of the PRODAVE gateway Figure 3 1 Adding a PRODAVE gateway Figure 3 2 Opening the PRODAVE gateway in edit mode Figure 3 3 Configuring the PRODAVE gateway Figure 3 4 Properties of a PRODAVE gateway Figure 3 5 Example for gateway signals Figure 3 6 Signals after import using option New Figure 3 7 Signals after import using option Add Figure 3 8 Signals after import using option Replace Copyright Siemens AG 2013 Process Automation o Oo ON NO O OA RA N SIMIT 7 PRODAVE Gateway Page Il SIEMENS Preface 1 PREFACE 1 1 Target Group This manual addresses you as a user of the SIMIT simulation system Here you will get to know how to use and handle a PRODAVE gateway in SIMIT As a prerequisite you need to be familiar with the general use of a personal computer and windows Furthermore knowledge of both the SIMIT basic system as well as common features of all SIMI
9. oduce access errors which can be handled in an appropriate OB in the control program Since the PRODAVE gateway can access the process image only you cannot access signals that are addressed as peripheral signals PIW PQW in the CPU Some SIMATIC controllers such as CPU 313C are hard wired with I O modules which have immutable address ranges These addresses cannot be accessed via the PRODAVE gateway Copyright Siemens AG 2013 SIMIT 7 PRODAVE Gateway Process Automation Page 3 SIEMENS Configuring the PRODAVE gateway 3 CONFIGURING THE PRODAVE GATEWAY In this chapter you learn how to configure a PRODAVE gateway 3 1 Creating a PRODAVE gateway To add a PRODAVE gateway to your project use the New Gateway command in the project tree Choose PRODAVE as gateway type see Figure 3 1 New Gateway PROFIBUS DP PROFINET IO OPC SERVER OPC CLIENT SHM PLCSIM e PRODAVE OK Cancel Figure 3 1 Adding a PRODAVE gateway In the SIMIT project you may assign an arbitrary name to your PRODAVE gateway To accept the default name just press Enter The gateway editor will now open automatically By double clicking the gateway or by using the context menu you can open the editor at any time later see Figure 3 2 Copyright Siemens AG 2013 SIMIT 7 PRODAVE Gateway Process Automation Page 4 SIEMENS Del Rename F2 Figure 3 2 Configuring the PRODAVE gateway Opening the PRODAVE gateway in edit mode
10. rface In any case please take care that in the SIMATIC Manager the PG PC interface is configured to the type of connection you chose NOTE gt To use the PRODAVE gateway with SIMIT you need the SIMATIC software PRODAVE in version 6 1 The PRODAVE software itself is not part of the SIMIT scope of delivery You may also need additional hardware such as MPI adapter or cable This is also not part of the SIMIT scope of delivery The PRODAVE gateway will not simulate any SIMATIC peripherals The PRODAVE gateway is used in SIMIT to directly access the process image of a SIMATIC controller The addresses that are actually available depend on how large the process image in your CPU is and what is defined in your hardware configuration SIMATIC PLC Peripherals Process SIMIT s PRODAVE gateway Figure 2 1 Functioning of the PRODAVE gateway Copyright Siemens AG 2013 SIMIT 7 PRODAVE Gateway Process Automation Page 2 SIEMENS Functioning of the PRODAVE gateway AN CAUTION You must not use peripheral modules in your controller that access the same addresses as your PRODAVE gateway since this would lead to concurrent access to the process image gt NOTES If you have configured peripheral modules in your hardware configuration you can still access their addresses using the PRODAVE gateway provided that these modules are currently not plugged This will cause the CPU to pr
Download Pdf Manuals
Related Search
Related Contents
Parte 2 - Vega Engineering Manual del propietario User's Manual +9055+3+4_100118 user manual short doorline t01-04 Atendimento Inicial a Emergências Ambientais HP 8673H User's Manual Copyright © All rights reserved.
Failed to retrieve file