Home

GRACE AdiaCal™ - Beyond Construction

image

Contents

1. 0 00 Source SCM3 Type None m Percent 0 00 Source Admix 1 Name Dose 0 00 Units oz cwt m CREATE PDF j select ig Admix 2 Name Dose 0 00 Units oz cwt sd ERB BEF OST ALe TOOL SAVE GRAPH SONFIG OPTIONS Admix 3 Name Dose 0 00 Units oz cwt z Mix Temperature 0 0 Mix Date Time Jan 01 2000 00 00 mi Sensor Enabled 7 READ LOGGER q SAVE LOG DATA Create a report in the standard pdf format by pressing CREATE PDF Print a report by pressing PRINT REPORT Your printer must be connected to your computer You can save the graph only portion of your screen as a picture by pressing SAVE GRAPH This picture can later be copied and pasted into any standard office application such as Word Excel PowerPoint or similar CONFIG OPTIONS enables you to switch from F to C or to change your user name Different Software tools are available for the AdiaCal You can access them by pressing the arrow under the label Software Tools Select the appropriate tool and press LAUNCH TOOL Your AdiaCal comes with the pre installed AdiaGraph tool Grace AdiaCal User Manual Page 4 Using AdiaGraph 1 0 to compare data from different tests Launch the AdiaGraph tool by selecting it in Software Tools and pressing the LAUNCH TOOL button new window will appear Press ADD PLOTS to add graphs from any AdiaCal file stored on your computer Brow
2. items from a list e g Fly Ash Slag etc in the SCM Type box units of measure etc If you use less than 4 sensors for any particular test you can uncheck the Sensor Enabled box for the sensors that are not being used Make sure you enter the correct Mix Date Time at which the Mix was done to be able to compare setting times for different mixes Grace AdiaCal User Manual Page 2 Logging and Retrieving test data Adiacal Logger Serial Number 112299 Logging G Low Battery OD Temperature F Sensor1 77 29 n Sensor2 77 12 Sensors 72 74 Sensor4 72 78 00 01 00 01 00 01 00 01 00 02 Sensor Selector Config Data Graph Tools map Water Cement Ratio 0 00 y 2llsils cor 2lEM Cement Source ID Cement Content 0 00 Units bs cy s a 1 l E e EVE 8 Loss I sro tosan READ CONFIG UPDATE CONFIG SCM2 Type None m Percent 0 00 Source r READ LOGGER save LOG DATA SCM3 Type None m Percent 0 00 Source Admix 1 Name Dose 0 00 Unts ozfewt CREATE PDE select JER Admix2 Name Dose 0 00 Unts oz em E ERALAIPORL LAUNCH TOOL save GRAPH _conricortions Admix 3 Name Dose 0 00 Units oz f ewt z Mix Temperature 0 0 Mix Date Time Jan o1 2000 00 00 R Sensor Enabled I ABOUT EXIT Press START LOGGING to start to record temperature data We recommend that you
3. start recording data at least 30 minutes before you place the first concrete cylinder in the AdiaCal You can now disconnect your computer If you do so EXIT the AdiaLog program Data will be collected and stored in your AdiaCal s internal memory for retrieval when you connect your computer again at a later time Press READ LOGGER to retrieve data at any time Note if the AdiaCal has been disconnected from your computer since starting to log data you have to first reconnect the AdiaCal and then relaunch the AdiaLog software to be able to retrieve data Press SAVE LOG DATA to save the current data on your computer Press READ CONFIG if you want to retrieve Mix Information only You can then edit the information for each sensor When finished editing Mix Information press the UPDATE CONFIG button to save the new Mix Information Press STOP LOGGING once you finished your test Grace AdiaCal User Manual Page 3 Workinq with data Adiacal Logger Serial Number 1122999 Ez i Logging G Low Battery Sensor4 72 78 60 i 1 v 1 1 p 1 1 1 1 1 Battery V 3 08 i i i i 00 01 00 01 00 01 00 01 00 01 00 01 00 02 Time since imm Config Data Graph Tools MixID Water Cement Ratio 0 00 Sensor Selector a SE HELL ce e Cement Source ID Cement Content 0 00 Units bs cy m GING GG SCM1 Type None m Percent 0 00 Source STAS LIGG j STORIQSGING READ CONFIG _uPDATECONFIG SCM2 Type None m Percent
4. GRACE AdiaCal User Manual AdiaCal Set Up AdiaLog 1 0 AdiaGraph 1 0 Initial Set Up Install the software on your computer Double click on the AdiaCalSetup icon on the Installation CD to launch the installation wizard Grace AdiaCal Installer Installation includes three software components of AdiaCal Suite AdiaLog for controlling the instrument Iv AdiaGraph for comparing results Vv AdiaPDF Writer for generating PDF reports IV If you don t need to create PDF reports you don t have to install AdiaPDF Writer During installation please accept all default options System Administrators please make sure that all AdiaCal users have write access to AdiaCal folder and all its subfolders DISCLAIMER AdiaCal results are only applicable to the samples tested AdiaCal results are only indicative of concrete performance Actual concrete tests according to relevant standards and practices are required to validate any results generated by AdiaCal AdiaCal results do not guarantee any concrete performance whatsoever 2007 Solidus Integration START INSTALLATION CANCEL INSTALLATION Follow the instructions on the screen Once the installation is finished connect your AdiaCal unit to your computer using the USB Cable provided Launch the AdiaLog software The program can be launched through the Start menu on the bottom left of your screen Start gt Programs gt Grace AdiaCal gt AdiaLog or by clickin
5. g on the shortcut button located on your desktop When you open the program for the first time you will be prompted to enter a username You are now ready to use your AdiaCal Grace AdiaCal User Manual Page I Capturing Mix information Use this drop down menu to select the unit you want to work with if you connect several AdiaCal units to your computer either directly or through a USB hub Each unit is identified by its serial number located next to the USB port on the center left side of your AdiaCal START LOGGING STOP LOGGING lone None m Percent 0 00 Source READ LOGGER saveLoGDATA None m Percent 0 00 Source Software Tools CREATE PDF j select f PRINTREPORT _LAUINCHTOOL saveGRAPH _conricortions Dose 0 00 Mix Date Time Jan 01 2000 00 00 il or ABOUT EXIT Dose 0 00 Dose 0 00 Pick a sensor on the Sensor Selector button row The numbers 1 through 4 correspond to the numbers next to the cylinder slots on your AdiaCal unit You can copy the information entered for one sensor to all other sensors by pressing the COPY button This is to avoid entering the same or similar information several times Enter your Mix data Mix ID Cement Source etc for the Mix to be placed in the corresponding cylinder slot The Mix composition data can always be edited and updated at a later time You can use drop down menus to pick
6. se to the folder where the file is stored select it and press OK A new window will appear with a preview of the file you selected In the new window you can select or deselect the curves you want to import by checking or unchecking the boxes in the legend Press ADD PLOTS again to add more graphs from other files up to a total of eight graphs Use the Graph Tools buttons located on the upper right to zoom in out or to move the graph Select a section of the graph on which to zoom in Zoom in out on a certain focal point Undo zoom and get back to the initial full graph view Grace AdiaCal User Manual Page 5