Home
Use and Care Manual
Contents
1. Measuring Functions Memory 5 last results 5 last results are A Navigates trough displayed 5 last results Makita LDO50P Technical Data Distance measurement ISO 16331 1 Accuracy with favourable 2 0 mm 0 08 in conditions Accuracy with unfavourable conditions 3 0 mm 0 12 in Range with favourable 50 m 164 ft conditions Range with unfavourable 35 m 115 ft conditions Smallest unit displayed 1 mm 1 16 in laser point 6 30 mm at distances 10 50 m Laser class 2 Laser type 635 nm lt 1 mW Protection class IP54 dust and splash water protected Autom laser switch off after 90 s Autom power switch off after 180 s Battery durability 2 x AAA up to 5000 measure ments 116 x 45 x 29 mm 4 57 x 1 77 x 1 14 in 0 10 kg 3 527 oz Dimension H x D x W Weight with batteries Temperature range Storage 25 to 70 C 13 to 158 F Operation 0 to 40 C 32 to 104 F favourable conditions are white and diffuse reflecting target white painted wall low background illumination and moderate temperatures unfavourable conditions are targets with lower or higher reflectivity or high background illumination or temperatures at the upper or lower end of the speci fied temperature range Tolerances apply from 0 05 m to 10 m with a confi dence level of 95 With favourable conditions the tolera
2. The device produces visible laser beams which are emitted from the instrument Itis a Class 2 laser product in accordance with e IEC60825 1 2014 Radiation safety of laser products Laser Class 2 products Do not stare into the laser beam or direct it towards other people unnecessarily Eye protection is normally afforded by aversion responses including the blink reflex WARNING Looking directly into the beam with optical aids e g binoculars telescopes can be hazardous CAUTION Looking into the laser beam may be hazardous to the eyes Subject to change drawings descriptions and technical data without prior notice Maximum peak radiant output power 0 95 mW Wavelength 635 nm Pulse duration gt 400 ps Pulse repetition frequency 320 MHz Beam divergence 0 16 x 0 6 mrad Makita LDO50P
3. Table of Contents Instrument Set up Limits of use Introduction Disposal ae Overview Electromagnetic Compatibility EMC Display FCC statement applicable in U S Insert batteries Laser classification Labelling Operations Switching ON OFF Message Codes Adjusting measuring reference Distance unit setting Measuring Functions Measuring single distance Permament measuring Add Subtract Pythagoras 2 point Pythagoras 3 point Memory 5 last results Technical Data Safety Instructions Areas of responsibility Permitted use Prohibited use Hazards in use Makita LDOSOP Instrument Set up Introduction The safety instructions and the user manual should be read through carefully before the product is used for the first time A The person responsible for the product must ensure that N all users understand these directions and adhere to them The symbols used have the following meanings WARNING Indicates a potentially hazardous situation or an unintended use which if not avoided will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor injury and or appreci able material financial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Overview Display NG LD050P On Measure Area ON
4. Volume Pythagoras v ee Subtract Memory RA J N J CLEAR OFF J amp Measuring Clear Off reference Unit Makita LDO50P Instrument Set up Display Insert batteries Battery Pythagoras Area Volume Memory Measuring te S reference Vee Lal ito Za fa Bre cae ABA any Onin Addition Units Subtraction Main line Makita LDO50P To ensure a reli able use do not use zinc carbon batteries Change batter ies when battery symbol is flash ing Ci Operations Switching ON OFF Clear Message Codes i 1x If the info icon appears with a number observe the instruc CLEAR CLEAR tions in section Message OFF OFF Codes Example 2 sec Device is Undo last action turned OFF pE ace Adjusting measuring reference 5 gt Distance is measured from the Distance is measured from the rear 2 front of the device of the device standard setting Distance unit setting Switch between the I following units UNIT 2 sec 0 000m 000 1 16 0 00m 0 00in 0 00ft 014 16in Makita LDO50P Measuring Functions Measuring single distance The last value mea sured is displayed Aim active laser at target Add Subtract Ea T w gt The next meas The next meas urementis added urement is sub to the previous tracted from the one previous one Makita LDO50P Target surfaces Measuring erro
5. ment must ensure that all users understand these directions and adhere to them Areas of responsibility Responsibilities of the manufacturer of the original equipment Makita Corporation Anjo Aichi 446 8502 Japan Makita Jan Baptist Vinkstraat 2 3070 Belgium Internet www makita com The company above is responsible for supplying the product including the User Manual in a completely safe condition The company above is not responsible for third party accessories Responsibilities of the person in charge of the instrument e To understand the safety instructions on the product and the instructions in the User Manual To be familiar with local safety regula tions relating to accident prevention Always prevent access to the product by unauthorised personnel Safety Instructions Permitted use e Measuring distances Tilt measurement Prohibited use e Using the product without instruction Using outside the stated limits e Deactivation of safety systems and removal of explanatory and hazard labels e Opening of the equipment by using tools screwdrivers etc e Carrying out modification or conversion of the product e Use of accessories from other manufac turers without express approval Deliberate dazzling of third parties also in the dark Inadequate safeguards at the surveying site e g when measuring on roads construction sites etc Deliberate or irresponsible behaviour o
6. n scaffolding when using ladders when measuring near machines which are running or near parts of machines or installations which are unprotected e Aiming directly in the sun Hazards in use WARNING Watch out for erroneous measurements if the instrument is defective or if it has been dropped or has been misused or modified Carry out periodic test measurements Particularly after the instrument has been subject to abnormal use and before during and after important measurements CAUTION Never attempt to repair the product your self In case of damage contact a local dealer WARNING Changes or modifications not expressly approved could void the user s authority to operate the equipment Limits of use Refer to section Technical data The device is designed for use in areas permanently habitable by humans Do not use the product in explo sion hazardous areas or in aggressive environments Makita LDOS50P Disposal CAUTION Flat batteries must not be disposed of with household waste Care for the environ ment and take them to the collection points provided in accordance with national or local regulations The product must not be disposed with household waste Dispose of the product appropri ately in accordance with the X national regulations in force in your memm country Adhere to the national and country specific regulations Product specific treatment and waste management can be dow
7. nce may deterio rate by 0 10 mm m for distances between 10 m to 30 m and by 0 15 mm m for distances above 30 m With unfavourable conditions the tolerance may dete riorate by 0 15 mm m for distances between 10 m to 30 m and by 0 20 mm m for distances above 30 m Makita LDO50P Distance measuring yes Min Max measuring yes Permanent measuring yes Addition Subtraction yes Area yes Volume yes Pythagoras 2 point 3 point Memory 5 results Message Codes If the message Error does not disappear after switching on the device repeatedly contact the dealer If the message InFo appears with a number press the Clear button and observe the following instructions No Cause Correction 204 Calculation error Perform measurement again 252 Temperature too Let device cool down high 253 Temperature too Warm device up low 255 Received signaltoo Change target surface weak measuring e g white paper time too long 256 Received signaltoo Change target surface high e g white paper 257 Too much back Shadow target area ground light 258 Measurement Correct range outside of meas uring range 260 Laser beam inter Repeat measurement rupted Care e Clean the device with a damp soft cloth Never immerse the device in water e Never use aggressive cleaning agents or solvents Makita LDOSOP Safety Instructions The person responsible for the instru
8. nloaded from our homepage Electromagnetic Compatibility EMC WARNING The device conforms to the most stringent requirements of the relevant standards and regulations Yet the possibility of causing interference in other devices cannot be totally excluded Safety Instructions FCC statement applicable in U S This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that inter ference will not occur in a particular instal lation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer ence by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Laser classification Labelling
9. rs can occur when meas uring to colourless liquids glass styrofoam or semi per meable surfaces or when aiming at high gloss surfac es Against dark surfaces the measuring time increases 7 EI Stops permanent measur ing The result is shown in the main line and the measured value above This process can be repeated as required The same process can be used for adding or subtracting areas or volumes i Measuring Functions Area AL 2 Se Aim laser at first target point 1 Volume gt 1 aZ 2 Aim laser at first target point The result is shown in the main line and the measured value above Aim laser at sec ond target point Aim laser at sec ond target point Makita LDO50P i The result is shown in the main line and the measured value above Aim laser at third target point Measuring Functions Pythagoras 2 point Aim laser at up per point Aim laser at up per point Aim laser rectan gular at lower Aim laser at rec tangular point The result is shown in the main line and the measured distance above Pressing the measuring key for 2 sec in the function activates auto matically Minimum or Maximum measurement Makita LDO50P The result is shown in the main line and the measured dis tance above Pressing the meas uring key for 2 sec in the function acti vates automatically Minimum or Maxi mum measure ment Aim laser at lower point
Download Pdf Manuals
Related Search
Related Contents
GPS ezTour Manual do utilizador Versão: 1.0 取扱説明書 - Ossur IGLOO FR551 Use and Care Manual Occupational Noise Measurement, ETC OmniPage 15 User`s Guide - Visioneer Product Support and Drivers Classificazione degli apparecchi per tipo/codice FNGME Brodit ProClip 532370 Power Step Lifts User Manual USER MANUAL Copyright © All rights reserved.