Home
Installation and user manual for SynLockswitches
Contents
1. The connection is done through the two red silicon cords of the SynLock switch If you install the POWER Control version of the SynLock switch please pay attention to not confuse the switched cable with the voltage supply cable Secure the 230 Volt voltage supply cable with the corresponding safety cable tie e Attach the cable which is to be switched For example this can be a CAT5 cable with RJ45 plug SURF Control and LAN Control or a control or supply cable POWER Control f Close the SynLock case Please proceed carefully in doing so At any rate avoid squeezing the cables If you have performed the steps mentioned above correctly the case should close without difficulty If not please check the previous steps 48653 Coesfeld Email synlock heddier com Tel 49 0 2546 911 0 Germany SynLock is a registered trademark of heddier electronic GmbH Copyright by heddier electronic GmbH Installation and user manual for SynLock switches g Switch on the 230 Volt voltage supply If this is the first SynLock switch installation the display reports through showing and a signal tone In case the SynLock switch displays something else it was previously programmed and implemented Possible errors and their causes Error The display remains to be dark Cause Operating voltage is not 230 Volt AC or not existent at all Solution Please check the installation Error The display does not show C
2. out machines etc However the operation of the SynLock switch is the same with every kind of type Booking time in SynLock switches a Briefly expose a valid customer card to a SynLock switch s reading zone A signal tone reports the identification of customer card Now an interval time e g 15 minutes for surfing the Internet is booked into the SynLock switch b The SynLock switches display shows the set interval time Remove the customer card from the SynLock switches reading zone Repeat step 6 a as many times you like for booking more time into your SynLock switch That maximum amount of time is thus set up by the customer card s account Release 04 2004 Page 4 Re book time from the SynLock a Expose a valid customer card to a SynLock switch s reading zone A signal tone indicates the customer card s identification An interval time e g 15 minutes for surfing the Internet is booked into the SynLock switch Please do not pay any attention to this process b Despite the previously illustrated instructions booking time into the SynLock switch do not remove the customer card from the SynLock switch s reading zone The credit which as been earlier booked into the SynLock switch is now reimbursed to your customer card c The successful ending of the re booking is indicated through a long signal tone and reported in the display Chip Possible errors and causes Error The SynLock switch sho
3. remove it after having successfully completed the initialization heddier electronic GmbH www synlock com Pascherhook 34 Email synlock heddier com Tel 49 0 2546 911 0 Release 04 2004 Page 2 3 Creating customer cards with the EasyProg card The EasyProg card enable you to easily programme the customer cards Unlike operating with the Master card here you do not need additional cashier and configurator software Yet only one type of SynLock switches can be programmed with an EasyProg card If you want to employ different types of SynLock switches you also need different EasyProg cards which heddier electronic GmbH delivers on request a Expose the EasyProg card briefly in front of the SynLock switch The SynLock switch reports with a signal tone and shows a time interval e g 15 minutes when surfing the Internet in the display Depending on the EasyProg card s programming different interval times and display variations hours minutes seconds or milliseconds can be used in the SynLock switch b Remove the EasyProg card right away from the reading zone of the SynLock switch The set up interval time flashes now in the display If you want to transfer this to your customer card please proceed with step 3 c If you want to programme the customer cards with a higher total amount of time repeat step 3 a until the desired total amount of time for the programming of the customer card is displayed Please keep
4. switch has already been programmed with another EasyProg card Solution Please check your EasyProg card Error The correct execution of the function is interrupted abruptly Cause Error while reading the EasyProg card Solution Expose the EasyProg card closer to the SynLock switch and proceed exactly as illustrated in step 3 4 Programming of the SynLock Switch with the Master card The function of the SynLock switch can be programmed with the configuration software in a considerably unrestricted fashion A decisive advantage in comparison to other systems is the fact that a network consisting of data cables is not used Those adjustments which are necessary for operating the SynLock switch are transported from the Master card to the SynLock switch through using the configuration software This manually performed transport substitutes costly networking a The SynLock switch displays Chip Expose the created Master card to the SynLock switch s reading zone b The display changes from Chip to Init and then back again to Chip c A signal tone reports the successful ending of the SynLock switch s programming Remove the Master card immediately from the SynLock switch s reading zone Release 04 2004 Page 3 Please use our online assistance which is integrated in software to get more information on the operation of the configuration software 5 Switching off the SynLock switch with the EasyProg or Ma
5. Installation and user manual for SynLock switches Security guidelines for utilisation The SynLock system enables you to switch administer and bill your electric devices data wires Internet accesses etc in a reliable and secure way To attain this operational security it is of high importance to pay attention to the following directives 1 Note down all of your employed passwords at a secure place which is only known to yourself It is highly recommended to inform a person of your trust about these passwords 2 Store your EasyProg and or Master card at a secret place Again it is highly recommended to inform a person of your trust about the storage s location Security guidelines for installation 1 An installation is only permissible through professional personnel Pay attention to the security guidelines on the type sign of the SynLock switch 2 Before installing disrupt the 230 Volt voltage supply 3 The installation of the SynLock switch is to be performed in dry places only 4 Secure the 230 voltage supply with the enclosed security cable tie which needs to be firmly attached to the SynLock switch s installation panel or to the respective ground 5 In case of damage please use only the original fuses of the manufacturer A replacing is only possible through professional personnel 6 Data wires which are laid in connection with 230 Volt inlets are to be secured adequately There is danger to
6. ause The SynLock switch was already initialized Solution Not necessary continue with new initialization 2 Initialization of SynLock switch After a having successfully installed the SynLock switch it perhaps needs to be initialized This is only necessary if the SynLock switch s display shows or if a former initialization is to be modified The initialization can be carried out by using the Master or EasyProg card a Expose the EasyProg or Master card in front of the SynLock switch at a maximum of 5 cm distance b A signal tone signifies the initialization s beginning if you use the EasyProg card c Watch the display in the SynLock switch It changes from to Init and then to Chip d Remove the EasyProg or Master card right away from the SynLock switch s reading zone The initialization was completed successfully Possible errors and their causes Error The SynLock switch shows no reaction Cause The SynLock switch was already programmed the password has been changed The SynLock switch has already been programmed for another customer Solution Please check the original initialization of the SynLock switch Please check the master card and adjust it to the password if required Error The initialization is suddenly cancelled Cause Errors while reading the EasyProg or master card Solution Expose the EasyProg or Master card a little bit closer to the SynLock switch and only
7. in mind that each time you expose the card the interval time is added up to the total amount of time e g 15 min 30 min 45 min ee c Remove the EasyProg card from the reading zone of the SynLock switch Now the display flashes and display the total amount of time which is to be programmed for the customer card You have 10 seconds to expose the a customer card to the SynLock switch A signal tone informs you that the customer card has been programmed successfully with the previously fixed total amount of time as shown below Remove the programmed customer card right away from the SynLock switch s reading zone You are able to programme the next customer card within the next ten seconds You can repeat this procedure as many times as you like Note Depending on the EasyProg card s model when programming of the customer card anew the remaining credit which is still on the customer card is either transferred to or added up to the newly programmed account 48653 Coesfeld Germany SynLock is a registered trademark of heddier electronic GmbH Copyright by heddier electronic GmbH Installation and user manual for SynLock switches d If do not wish to programme any further customer cards the SynLock switch returns automatically to ist original operating status after a 10 second interlude The display shows Chip Possible errors and their causes Error The SynLock switch does not react Cause The SynLock
8. ing mode This function should be made use of whenever processes must not interrupted during the operating mode e g commercial washing machine Displaying the credit on the Customer Card Through programming the Master card the SynLock switch can be used to display the customer card s credit Here it is possible to select between displaying the remaining time interval or the remaining amount of money In combination with the customer cards which were created with EasyProg cards we recommend the displaying of the remaining time interval This makes sense as the sales price of the customer card can be arranged individually If customer cards which were created through using Master cards it is suggested to display the remaining time interval Here credits up to 99 99 of the respective currency XX XX e g 23 55 are displayed Remaining credits starting from 100 of the respective currency are displayed in the format XXXX e g 123 Please mind that format does not display those credits which are fewer than 1 in the respective currency e g 123 34 Credits higher than 9999 in the respective currency cannot be displayed either In these rare cases we recommend to define a bigger currency e g 1 10 A SynLock switch which has been modified to display remaining credits cannot execute any switching processes anymore A later re programming however is possible a Briefly expose a valid customer card to a SynLock sw
9. is a registered trademark of heddier electronic GmbH Copyright by heddier electronic GmbH
10. itch s reading zone b The customer card s remaining credit is displayed according to definition set up above Possible errors and causes Error The SynLock switch shows no reaction Cause The SynLock switch belongs to another operating system and is not unlocked for your customer card Solution Use a fitting customer card Error The correct execution of the function is suddenly interrupted Cause Error while reading the customer card Solution Expose the customer card a little closer to the SynLock switch heddier electronic GmbH www synlock com Pascherhook 34 Email synlock heddier com Tel 49 0 2546 911 0 Release 04 2004 Page 5 Please use our online assistance which is integrated in software to get more information on the operation of the configurator software 7 Diagnosis Functions With the Master card you are able to extract and read supplementary information from the SynLock switches These information are saved on the master card until the next operation The configurator software enables you to send these supplementary information to the technical support of heddier electronic Ltd via email support heddier com Here the information can be analyzed in detail The data are encoded in order to prevent an authorized reading of the emails Our technical support is happy to provide you with further detailed information on this feature We wish you good luck and hope you enjoy working w
11. ith your SynLock components Your heddier electronic GmbH 48653 Coesfeld Germany SynLock is a registered trademark of heddier electronic GmbH Copyright by heddier electronic GmbH Installation and user manual for SynLock switches Release 04 2004 Page 6 EG Konformit tserkl rung zur CE Kennzeichnung F r unser Erzeugnis SynLock RFID Schalter wird hiermit best tigt dass es den wesentlichen Schutzanforderungen entspricht die in den Richtlinien des Rates ber elektrische und elektronische Produkte festgelegt sind 1 89 336 EWG EMV Richtlinie 2 73 23 bzw 93 68 Niederspannungsrichtlinie 3 99 5 RTTE Richtlinie Sendefunkger te Telekommunikations Endger te Zur Beurteilung wurden folgende Normen herangezogen Zul Elektromagnetische Vertr glichkeit nach EN55022 EN55024 EN61000 3 2 und EN61000 3 3 niedergelegt in Pr fbericht 22 21 Zu 2 Elektrische Sicherheit nach EN60950 und EN50364 niedergelegt in Pr fbericht 22 21S Zu 3 Funk bzw Senderpr fung nach EN300 330 EMV Pr fung nach EN301489 3 Elektrische Sicherheit nach EN60950 Nachweis zur Sicherheit von Personen in elektromagnetischen Feldern EN50364 Diese Erkl rung wird durch den Hersteller abgegeben heddier electronic GmbH Dipl Ing Clemens Heddier Gesch ftsf hrer Coesfeld den 01 03 2004 heddier electronic GmbH Pascherhook 34 48653 Coesfeld Germany www synlock com Email synlock heddier com Tel 49 0 2546 911 0 SynLock
12. life if the aforementioned security guidelines for installation are disregarded Dear customer We thank you for buying the SynLock switch and the trust you have awarded to us Please read these instructions carefully The correct installation and implementing is essential for reliable functioning Our technical support is happy to assist you in case you have any questions Just contact support heddier com oder Tel 49 0 2546 911 25 heddier electronic GmbH www synlock com Pascherhook 34 Release 04 2004 Page 1 1 Installation of SynLock Switch a Open the SynLock case To do this remove the two screws which can be seen at the front The relevant tool is part of the SynLock switch s delivery package b Remove the rear plate of the front case Proceed extremely carefully and be careful to not damage the interior s electronic c Fit the installation panel at an appropriate location It is recommended to use a 60 mm switch which is often employed in the filed of electric installation However you can install the SynLock switch on any suitable surface you like In case you install the SynLock switch for exterior purposes you need to chose a dry place for the installation Direct exposing to dampness through rain or snow are to be avoided Corresponding safety measure are to be arranged d Connect the SynLock switch to the 230 Volt AC inlet Before doing so make sure that the 230 Volt AC inlet has no voltage
13. n is suddenly interrupted Cause Error while reading the customer card Solution Expose the customer card a little closer to the SynLock switch heddier electronic GmbH www synlock com Pascherhook 34 Email synlock heddier com Tel 49 0 2546 911 0 Note A re booking of the SynLock switch s credit is only possible with exactly the customer card which has been previously used for the booking A re booking with another customer card is not possible There can be modifying operating modes depending on the SynLock switches programming this also needs to be taken into consideration when using the customer card The following modifying operating modes are possible a Single Booking Mode There can only be one time interval booked into the SynLock switch A further booking is only possible after the time interval s expiration e g solarium protection of misuse b No re booking allowed The user can switch off the SynLock switch but the credit that is saved in the SynLock switch is not reimbursed to his customer card 48653 Coesfeld Germany SynLock is a registered trademark of heddier electronic GmbH Copyright by heddier electronic GmbH Installation and user manual for SynLock switches c No switching off allowed The user does not have the option to switch off the once activated SynLock switch A re booking is also not possible As a rule this function should be combined with the single book
14. reading the Master card Solution Expose the Master Card closer to the SynLock switch Possible errors and causes Error The SynLock switch shows no reaction Cause The SynLock switch has already been programmed the password has been changed The SynLock switch has already been programmed for another customer Solution Please check the SynLock switch s original initialization Please check your Master card and if necessary adjust the password to it Error The initialization is suddenly interrupted Cause Error while reading the Master card Solution Expose the Master card closer to the SynLock switch and only remove it after having successfully completed the switching off process heddier electronic GmbH www synlock com Pascherhook 34 Email synlock heddier com Tel 49 0 2546 911 0 48653 Coesfeld Germany SynLock is a registered trademark of heddier electronic GmbH Copyright by heddier electronic GmbH Installation and user manual for SynLock switches 6 Operation of the SynLock switch with the customer Card Customer cards can be created with the EasyProg card at the SynLock switch or with the configuration programme at the PC Customer cards which were created with the EasyProg card work only with one type of SynLock switch Customer cards which were created with the configuration software though can control up to 16 different kinds of SynLock switches e g floodlight kiddie rides work
15. ster card It is sometimes necessary to switch off an activated switched on SynLock switch while still operating the system If desired this can be done through using the customer card If this is not possible customer left the location without having turned off the device you have the option to switch off the SynLock switch with the EasyProg or Master card a The display shows an arbitrary amount of time Expose the correct EasyProg or Master card in front of the SynLock switch b A signal tone reports the successful switch off process The display changes automatically and shows Chip c The switch off process is completed Remove the EasyProg or Master card instantly from the SynLock switch s reading zone Note The time credit within the SynLock switch is irreversibly deleted after the switching off process A later reimbursement on the customer card is not possible Note Likewise the deletion of customer cards which have been created through the EasyProg card is also possible see step 3 Creating customer cards with the EasyProg card Possible errors and their causes Error The SynLock switch shows no reaction Cause The SynLock switch has already been programmed with another Master card The SynLock switch s password has been changed Solution Please check your Master card and use the correct password Error The correct execution of the function is interrupted abruptly Cause Error while
16. ws no reaction Cause The SynLock switch belongs to another operating system and is not unlocked for your customer card The used customer card is not authorized to unlock this SynLock switch e g Kiddie card Pay TV Solution Use a fitting customer card Error The SynLock switch reports with a signal tone but the information in the display does not change Cause The customer card was identified correctly but does not have any credit anymore The customer card was identified correctly but the booking s maximum amount has been reached The used customer card is not authorized to unlock this SynLock switch e g Kiddie card Pay TV Solution Use a correct customer card which has enough credit and has not reached the booking s maximum amount Error The correct execution of the function is suddenly interrupted Cause Error while reading the customer card Solution Expose the customer card a little closer to the SynLock switch Possible errors and causes Error The SynLock switch shows no reaction Cause The SynLock switch belongs to another operating system and is not unlocked for your customer card The SynLock switched was not unlocked with your customer card Solution Use a fitting customer card Error The SynLock switch reports with a signal tone but does not switch off Cause The function switch off is not admissible for this SynLock switch Error The correct execution of the functio