1. Klinkmann Automation DAMATIC I O Server 14 For each Topic there is a Discrete item with name STATUS that indicates the state of communication with this Topic This item is set to 0 when communication with the Topic fails and set to 1 when communication is successful For each Topic the special Discrete Read Only item KEEPALIVE can be activated The value of KEEPALIVE changes from 0 to 1 or from 1 to 0 when any command is sent to this Topic GTW CIS This item can be used to create artificial delivery of new data from Server to client application if needed for example if accessing to Damatic data from Wonderware Industrial SQL Server and no new values are received from GTW CIS Examples of item names d 24 Discrete Read Only corresponds to preconfigured table index 24 zero or non zero value i e pr JVETCNP1 out Integer Read Write corresponds to Damatic XD variable e pr JVETCNPT1 o0ut r e pr 4XIS5ANA4 Real Read Write corresponds to Damatic XD variable e pr 4XISSANA4 R e pr lic100 v Damatic XD vector which contains floating point data and corresponds to Damatic XD variable e pr lic100 the whole vector will be read R e pr lic100 vf Message the type of the status of values is set to text Read Only contains return value all fault bits for Damatic XD real vector e pr lic100 i e pr lic100 elem 1 10 Damatic XD vector which contains integer data and corresponds to Damatic
2. 1 As a self extracting archive IOServerInfrastructure exe if downloaded from Klinkmann s web site 2 On one distribution disk floppy To install the I O Server Infrastructure from the self extracting archive run the IOServerinfrastructure exe and proceed as directed by the I O Server Infrastructure Setup program To install the I O Server Infrastructure from the distribution disk on MS Windows NT 1 Insert the I O Server Infrastructure disk into a floppy drive A or B 2 Select the Run command under the Start menu 3 Type A SETUP or B SETUP 4 Click on OK 5 Proceed as directed by the I O Server Infrastructure Setup program To uninstall the I O Server Infrastructure start Control Panel select Add Remove Programs and select the IO Server Infrastructure from the list of available software products Click on Add Remove and proceed as directed by the UnInstallShield program Note The I O Server Infrastructure installation will be rejected if Wonderware FS2000 Common Components are already installed on same computer DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 5 Starting the DAMATIC I O Server After the DAMATIC Server is initially installed start up the DAMATIC program If the Server starts up as an icon double click on the icon to open the server s main window The following will appear 2 DAMATIC OF x Password
3. Asa self extracting archive 09010xxx EXE where xxx is the current latest version of Server if downloaded from Klinkmann s web site 2 From installation on CD 3 On two or three distribution disks floppies To install the DAMATIC I O Server from the self extracting archive run the 09010xxx EXE and proceed as directed by the DAMATIC I O Server Setup program To install the DAMATIC I O Server from CD or distribution disks on MS Windows NT 2000 XP or 95 98 1 Insert the CD with Klinkmann Software into CD drive or insert the DAMATIC I O Server Disk1 into a floppy drive A or B 2 Select the Run command under the Start menu 3 Run STARTUP EXE if installing from CD or SETUP EXE if installing from distribution disks floppies 4 If installing from CD select Protocol Servers DDE SuiteLink OPC find DAMATIC SL and DDE Server and click on Setup 5 Proceed as directed by the DAMATIC I O Server Setup program When installation is finished the subdirectory specified as a folder where to install the DAMATIC I O Server files will contain the following files DAMATIC EXE The DAMATIC I O Server Program This is a Microsoft Windows 32 bit application program DAMATIC HLP The DAMATIC 1 0 Server Help file DAMATIC CFG An example configuration file LICENSE TXT Klinkmann Automation software license file To uninstall the DAMATIC I O Server start Control Panel select Add Remove Programs and sele
4. Cancel to continue without user password changing Note The User Password checking can be disabled by adding PasswordNotUsed 1 entry in the WIN INI file see Troubleshooting WIN INI entries section DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 7 Configuring the DAMATIC I O Server After the DAMATIC 1 0 Server is initially installed a small amount of configuration is required Configuring the Server automatically creates a DAMATIC CFG file which holds all of the topic definitions entered as well as the configuration of sockets This file will automatically be placed in the same directory in which DAMATIC EXE is located unless the path where the configuration file will be placed is a specified via the Configure Server Settings command To access the commands used for the various configurations open the Configure menu JE DAMATIC Password Qiang tit Help Socket Definition Topic Definition Server Settings Server Settings Command A number of parameters that control the internal operation of the Server can be set In most cases the default settings for these parameters provide a good performance and do not require changing However they can be changed to fine tune the Server for a specific environment To change the Server s internal parameters invoke the Configure Server Settings command The Server Settings dialog box will appear Proto
5. The communication state item STATUS is set to 0 after PortErrorRetries unsuccessful retries The default values they are used if WIN INI file does not contain these entries are PortErrorRetries equal to 2 and SlowPolllnterval equal to 60 seconds MaxReadIndexes and MaxWritelndexes The default number of maximum write and read indexes processed in one command is set to 512 values both for write and read commands This default value is possible to change by adding some lines in the WIN INI file DAMATIC section like MaxWritelndexes 200 MaxReadlndexes 100 DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 25 In above case there will be maximum 200 writes in one indexed write command and maximum 100 reads in one indexed read command These values can be adjusted to achieve the best performance of execution WriteRetrylndefinitely As default the DAMATIC I O Server tries to execute the write and create connection to name commands PortErrorRetries times if error response is received or waits for answer to these commands PortErrorRetries Reply Timeout entered at DAMATIC Socket Settings seconds If still there is no good response then these commands are rejected It is possible to use the special WIN INI DAMATIC section entry WriteRetrylndefinitely 1 to configure the Server to wait for responses to write and create connection to name commands indefinitely i e until some answe
6. XD vector e pr lic100 first 10 elements will be read from this vector i e pr lic100 elem 4 Integer Read Write corresponds to element with address 4 from Damatic XD integer vector e pr lic100 R 10 w Real Write Only used for writing of float data to preconfigured table index 10 R 10 f Integer the type of the status of values is set to numeric Read Only corresponds to preconfigured table index 10 value in table is float fault status value i e pr lic100 elem 6 F Message the type of the status of values is set to text Read Only contains return value all fault bits for Damatic XD variable e pr lic100 elem 6 i e pr 2XISSINTS2 1 Integer will be read only once and and no connection to name will be opened corresponds to Damatic XD variable e pr 2XISSINTS2 DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 15 Using the DAMATIC I O Server with InTouch To access to items points on the Damatic XD system from InTouch the Access Names and Tag names should be defined in WindowMaker Defining the Access Names InTouch uses Access Names to reference real time I O data Each Access Name equates to an I O address which can contain a Node Application and Topic Ina distributed application I O references can be set up as global addresses to a network I O Server or local addresses to a local I O Server To define the Access Names in Win
7. this re establishing the following must be done In Excel all spreadsheets containing DDE channels must be closed and then re opened During each spreadsheet re opening Excel displays message Re establish remote links and waits for user reply If user reply is Yes then all DDE links are re established In InTouch the re establishing of I O links can be performed by SpeciallReinitialize I O option from WindowViewer main menu The DAMATIC I O Server waits for reply to each message sent to GTW CIS i e next command to GTW CIS can not be sent before answer to previous command is received each message has it s sequence number of message and if next command to GTW CIS is sent before answer to previous answer is received then the order of these sequence numbers can be destroyed If for some reason the GTW CIS temporarily stops responding to commands from Server then the situation when communication is freezed can happen In this case only way to restore the communication is to perform the re establishing of I O links DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 24 WIN INI entries The first time you run the DAMATIC I O Server configuration most of the items in the following list will automatically appear in the WIN INI file It is usually in the C WINDOWS directory It is an ASCII file and can be altered manually if you wish with any text editor e g MS Windows Notepad Do n
8. 10 could be the item name for Damatic XD variable with name e pr lic100 elem 1 10 and this Damatic XD variable is a vector with 10 integers For each Topic there is a special Integer Read Only item NOF_PENDING_WRITES implemented This item can be used to monitor how many not executed write commands are waiting To avoid the increasing of memory occupied by not executed write commands the NOF_PENDING_WRITES item can be used in the following way activate the hot link with NOF_PENDING_WRITES item and start to monitor it activate new write command by poking new values only if value of NOF_PENDING_WRITES becomes equal to 0 e g all previous writes are executed and memory occupied by them is freed Note It is strongly recommended to use consecutive Write Only indexes when executing a big amount of writes e g 512 values at once Otherwise there can considerable delays before executing these writes first time the new value to Write Only index can be written only after the type of this Damatic XD pre configured table index is obtained from Damatic XD system If addresses of indexes are consecutive then Server can do it by one or few additional read XD type commands but if addresses are scattered then many read XD type commands could be needed In this case the special item NOF_PENDING_WRITES item could be useful to determine when the write command is completed DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF
9. 2XISSANAV v and then you must press CTRL SHIFT ENTER to execute a formula Note Refer to the Microsoft Excel manual for complete details on entering Remote Reference formulas for cells Writing Values to DAMATIC I O Server Points Values may be written to the Server from Microsoft Excel by creating an Excel macro that uses the POKE command The proper command is entered in Excel as follows channel INITIATE DAMATIC topicname POKE channel itemname Data Reference TERMINATE channel RETURN The following describes each of the above POKE macro statements channel INITIATE DAMATIC topicname Opens a channel to a specific topic name defined in the Server in an application with name DAMATIC the executable name less the EXE and assigns the number of that opened channel to channel Note By using the channel INITIATE statement the word channel must be used in the POKE statement instead of the actual cell reference The applicationname and topicname portions of the formula must be enclosed in quotation marks DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 21 POKE channel itemname Data Reference POKEs the value contained in the Data Reference to the specified item name actual location in the Damatic XD system via the channel number returned by the previously executed INITIATE function Data Reference is the row column ID of the cell containing th
10. Configure Help User Password The Server includes commands for User Password input and change If the password is valid then the user can read and write data from to the Damatic XD system The user also can work with the default password in this case he can only read data from the Damatic XD system Up to eight characters can be set as a user password To access the commands used for password input and change open the Password menu JE DAMATIC 3E Configure Help Input Password Change Password Input Password To input a user password perform a registration invoke the Input Password command and User Password Input dialog box will appear User Password Input User Password o em Type the user password in the User Password field The typed characters are displayed as asterisks Click on OK to process the typed value or click on Cancel to continue without registration DAMATIC 1 0 Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 6 Change Password To change a user password invoke the Change Password command and Change User Password dialog box will appear Change User Password Old Password New Password Retype New Password o om Type the appropriate values in the Old Password New Password and Retype New Password fields The typed characters are displayed as asterisks Click on OK to process the typed values or click on
11. DAMATIC I O Server for Microsoft Windows User Manual Ver 2 x Rev 2 8 DR 090 10 KLINKMANN AUTOMATION P O Box 38 FIN 00371 Helsinki Finland tel int 358 9 5404940 fax int 358 9 5413541 www klinkmann com Klinkmann Automation DAMATIC I O Server i Table Of Contents DAMATIC DDE Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 1 VALMET DAMATIC I O Server Overview The VALMET DAMATIC I O Server hereafter referred to as the DAMATIC I O Server or Server is a Microsoft Windows 32 bit application program DAMATIC EXE that acts as a communication protocol Server and allows other Windows application programs access to data from the Damatic XD system s GTW CIS Gateway Computer Interface Stations The Server may be used by any Microsoft Windows program that is capable of acting as a DDE FastDDE or SuiteLink Client The Damatic I O Server requires an Ethernet card and TCP IP protocol supporting Windows Sockets interface installed on the computer to communicate with the GTW CIS connected to the Ethernet network Any Ethernet network adapter e g 3COM Etherlink Ill may be used to communicate with the Damatic XD system Communication Protocols Dynamic Data Exchange DDE is a communication protocol developed by Microsoft to allow applications in the Windows environment to send receive data and instructions to from each other It implements a client server relationship
12. Enabling this option will cause the server to start as a Windows NT service Windows NT offers the capability of running applications even when a user is not logged on to the system This is valuable when systems must operate in an unattended mode Enabling this option and rebooting the system will cause the Server to run as a Windows NT service However to view configuration information or to reconfigure the Server the user must log on to the system Any Server related problems that may arise such as missing adapter cards licensing failures or device drivers not loading will not be visible to the user until a log on is performed Disabling this option and rebooting the system will cause the Server to run as a Windows NT application program once again When all entries have been made click on OK Socket Definition Command To configure the Socket used for communications with Damatic XD system s GTW CIS invoke the Configure Socket Definition command The DAMATIC Socket Settings first dialog box will appear DAMATIC Socket Settings DAMATIC Sockets Modify ei Delete To modify or examine an existing Socket select the Socket name and click on Modify To define a new Socket click on New The DAMATIC Socket Settings second dialog box will appear DAMATIC 1 0 Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 9 DAMATIC Socket Settings Socket Name Ethemet Reply Timeou
13. ally enter the tag name in this field Note The tag name can only be used if it follows the conventions listed in the Item Names section Once all entries have been made click on the Save button in the top dialog box to accept the new tagname To define additional tagnames click on the New button To return to the WindowMaker main screen select Close DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 20 Notes on Using Microsoft Excel Data from the DAMATIC XD system may be accessed from Excel spreadsheets To do so enter a formula like the following into a cell on the spreadsheet DAMATIC topic item In the formula topic must be replaced with one of the valid topic names defined during the Server configuration process Replace item with one of the valid item names specified like described in the Item Names section Reading Values into Excel Spreadsheets Values may be read directly into Excel spreadsheets by entering a DDE formatted formula into a cell as shown in the following examples DAMATIC xd17 i e pr 2XISSINTS2 DAMATIC GTWCIS i e pr lic100 elem 4 DAMATIC xd R 10 f Vectors arrays may be read directly into Excel spreadsheets by selecting the range of cells in which you want to read the vector data then building a DDE formatted formula as shown in the following example DAMATIC xd1 R e pr
14. between two concurrently running applications The server application provides the data and accepts requests from any other application interested in its data Requesting applications are called clients Some applications such as Wonderware InTouch and Microsoft Excel can simultaneously be both a client and a server FastDDE provides a means of packing many proprietary Wonderware DDE messages into a single Microsoft DDE message This packing improves efficiency and performance by reducing the total number of DDE transactions required between a client and a server Although Wonderware s FastDDE has extended the usefulness of DDE for our industry this extension is being pushed to its performance constraints in distributed environments The DAMATIC 1 0 Server supports the FastDDE Version 3 an extension to Wonderware s proprietary FastDDE Version 2 This extension supports the transfer of Value Time Quality VTQ information The original DDE and FastDDE Version 2 formats are still supported providing full backward compatibility with older DDE clients FastDDE Version 3 works on Windows 9x systems as well as Windows NT systems NetDDE extends the standard Windows DDE functionality to include communication over local area networks and through serial ports Network extensions are available to allow DDE links between applications running on different computers connected via networks or modems For example NetDDE supports DDE between applications running
15. ce Accessing Remote Items via the I O Server The communication protocol addresses an element of data in a conversation that uses a three part naming convention that includes the application name topic name and item name The following briefly describes each portion of this naming convention application name The name of the Windows program server that will be accessing the data element In the case of data coming from or going to Damatic XD system s GTW CIS via this Server the application portion of the address is Damatic topic name Meaningful names are configured in the Server to identify specific devices These names are then used as the topic name in all conversations to that device For example XD1 Note You can define multiple topic names for the same device GTW CIS to poll different points at different rates item name A specific data element within the specified topic For example when using this Server items can be specified by configured table indexes or by names of Damatic XD variables in the Damatic XD system The term point is used interchangeably with the term item in this User Manual For more information on item point names see the Item Names section later in this manual DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 3 Installing the DAMATIC I O Server Installing the I O Server The DAMATIC I O Server installation package can be supplied 1
16. cial switch d is used For example invoke the File Run command and enter the following command DAMATIC d c path Note There is no limit to the number of configuration files that may be created although each must be in a separate directory DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 11 Topic Definition Command The DAMATIC I O Server allows connection to one or more GTW CIS and supports multiple topics allowing different data update rates for each topic The user provides each topic with an arbitrary name used as the Topic Name for all references to this topic The following steps are taken to define the Topic 1 Invoke the Configure Topic Definition command The Topic definition dialog box will appear Topics Modify Delete 2 To modify an existing topic select the topic name and click on Modify To define a new topic click on New The DAMATIC Topic Definition dialog box will appear da DAMATIC Topic Definition Application Name DAMATIC Topic Name far Socket fEthemet Type of Status Text Numeric Update Interval 3000 milliseconds v Internal Cycle Time 2000 milliseconds Cancel 3 Enter the Topic Name Note If using InTouch the same Topic Name is to be entered in the Add Access Name dialog box described in the Using the DAMATIC I O Server with InTouch section 4 Select the Socket to associate i
17. clicking on the Access Name button The Access Names dialog box will appear Close Add Modify Delete Select the appropriate Access Name and click on Close If the Access Name has not been defined as previously described click on Add and define the Access Name now The Details dialog box will appear displaying the selected Access Name Initial Value jo Min EU 32768 Max EU 132767 Deadband jo Min Raw 32768 Max Raw 32767 i Conversion Eng Units Fe C Square Root Item I Use Tagname as Item Name Log Deadband fo For integers and reals fill in the Min EU Max EU Min Raw and Max Raw fields These fields control the range of values that will be accepted from the Server and how the values are scaled If no scaling is desired Min EU should be equal to Min Raw and Max EU equal to Max Raw Enter the DAMATIC item name to be associated with this tagname in the Item field in the Details box DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 19 Initial Value jo Min EU 32768 Max EU 132767 Deadband jo Min Raw 1 232768 Max Raw 32767 3 m Conversion Eng Units gren i a Square Root Item fi e pr 2XI55INTS2 Use Tagname as ltem Name Log Deadband jo Refer to the Item Names section below for complete details Where applicable the Use Tagname as Item Name option may be selected to automatic
18. col Timer Tick 50 msec IF NetDDE being used Cancel Confiquration File Directory DADAMATICS I Start automatically as Windows NT Service The following describes each field in this dialog box Protocol Timer Tick This field is used to change the frequency at which the Server checks for data to process This frequency real value depends on total amount of data the Server is requesting from the Damatic XD system The desired Protocol Timer Tick value must be enough to allow process all requests at the shortest time desired to update data from the Damatic XD system The default value is 50 milliseconds DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 8 NetDDE being used Select this option if you are networking using Wonderware NetDDE Configuration File Path The first field is used to specify the path disk drive and directory in which DAMATIC will save its current configuration file The DAMATIC EXE will use this path to load the configuration file the next time it is started Note Only the path may be modified with this field The configuration file is always named DAMATIC CFG Note There is no limit to the number of configuration files created although each must be in a separate directory When using the DAMATIC Server with InTouch it is a good practice to place the configuration file in the application directory Start automatically as Windows NT Service
19. ct the DAMATIC IO Server from the list of available software products Click on Add Remove and proceed as directed by the UnInstallShield program Notes 1 The DAMATIC I O Server is developed with Wonderware I O Server Toolkit ver 7 0 and needs the Wonderware FS2000 Common Components to be installed on computer where the DAMATIC I O Server is running The Wonderware FS2000 Common Components are installed automatically when any of Wonderware FS2000 Components e g InTouch or some Wonderware I O server is installed DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 4 2 If DAMATIC I O Server will run on PC where Wonderware FS2000 Common Components are not installed then a special I O Server Infrastructure installation package can be obtained from Klinkmann Automation see Installing the I O Server Infrastructure section below This I O Server Infrastructure installation package contains the minimum set of software needed to run the DAMATIC I O Server and these infrastructure files must be install prior to executing the DAMATIC I O Server 3 The HASP key is needed for full time running of DAMATIC I O Server The HASP Driver setup is performed during the Server setup Without HASP Driver installed the DAMATIC I O Server will run only 1 hour with all features enabled Installing the I O Server Infrastructure The I O Server Infrastructure installation package can be supplied
20. dowMaker node invoke the Special Access Names command The Access Names dialog box will appear Access Names Close Mody pelete pr Click on Add The Add Access Name Dialog Box will appear Add Access Name Access Name zdi R et Node Name Cancel node2 Application Name damatic Topic Name xd Ve protocol to use C DDE SuiteLink When to advise server Advise all items Advise only active items Note If Add is selected this dialog box will be blank when it initially appears Data has been entered here to illustrate the entries that are made DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 16 The following fields are required entries when entering an Access Name Definition Access Name In the Access Name box type the name you want InTouch to use to this Access Name For simplicity use the same name that you will use for the Topic Name here Node Name If the data resides in a network I O Server in the Node Name box type the remote node s name Application Name In the Application Name box type the actual program name for the I O Server program from which the data values will be acquired In case the values are coming from the DAMATIC 1 0 Server the DAMATIC is used Do not enter the exe extension portion of the program name Topic Name Enter the name defined for the topic in the DAMATIC I O Server to
21. e data value For itemname use some of the valid item names specified like described in the Item Names section Note Inside itemname quotation marks which belong to item name must be duplicated e g T e pr 4XIS5ANA2 wW TERMINATE channel Closes the channel at the end of the macro Some applications have a limited number of channels Therefore they should be closed when finished Channel is the channel number returned by the previously executed INITIATE function RETURN Marks the end of the macro The following is an example of Excel macro used to poke value from cell B2 to item i e pr 4XISSANA2 w PokeMacro Ctrl a INITIATE DAMATIC xd1 POKE A2 i e pr 4XISSANA2 w B2 ON TIME NOW 0 01 TerminateDDE Channel RETURN TerminateDDEChannel TERMINATE A2 RETURN Note Refer to the Microsoft Excel manual for complete details on entering Remote Reference formulas for cells DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 22 Troubleshooting Monitoring the Status of Communication with GTW CIS For each topic there is a built in discrete item which indicates the state of communication with the GTW CIS The discrete item STATUS is set to 0 when communication fails and set to 1 when communication is successful From InTouch the state of communication may be read by defining an I O Discrete tagname and associating it with the topic confi
22. ful connection to name by receiving the first data value Sometimes it can be necessary to determine this connection to name result immediately after connection to Damatic XD variable name command was executed For example the following settings NoZeroOnltemActivation 99 ConnectionNameValueOK 98 ConnectionNameValueBad 97 DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 26 will cause the following value of 99 will be delivered to client application immediately after the item is activated and then after connection to Damatic XD variable name command was executed for great amount of items it can take considerable time to execute this command for all items depending on this command result the value of 98 will will be delivered to client application if connection was successful or value of 97 if connection was unsuccessful In case the connection was successful the real values from Damatic XD system will start to come and replace the value 98 Note For NoZeroOnltemActivation ConnectionNameValueOK and ConnectionNameValueBad entries used with discrete variables with syntax d Damatic variable name only positive values can be used ShortShowSendReceive As default the DAMATIC I O Server logs to Wonderware Logger ALL outgoing and incoming data if Show Send and or Show Receive is checked in Server s System Menu Sometimes for debugging purposes it would be necessary to decrease t
23. gured for the GTW CIS and using STATUS as the Item name m Initial Value Input Conversion On Msg On Off d Direct C Reverse AG Fatal i OffMsg Access Name xdi Item s TATUS T Use Tagname as ltem Name From Excel the status of the communication may be read by entering the following formula in a cell DAMATIC topic STATUS Monitoring the Status of Communication with InTouch InTouch supports built in topic names called DDEStatus and IOStatus that are used to monitor the status of communications between the Server and InTouch For more information on the built in topic names DDEStatus and IOStatus see your online InTouch User s Guide The status of communication between the Server and InTouch can be read into Excel by entering the following DDE reference formula in a cell on a spreadsheet in following examples xd1 is the Topic Name configured for DAMATIC I O Server view DDEStatus xd1 or view lOStatus xd1 Delay during opening connections to names If many connections to names of XD variables must be opened simultaneously then there would be a considerable delay before all modules to CIS are opened In Excel each cell contains N A until channel is opened and first data value is received In InTouch the end of this delay can be determined by setting some impossible value e g empty for I O Message type items as Initial Value and then waiting the change of this
24. he total amount of logged information this can be done by adding the following entry to WIN INI file DAMATIC section ShortShowSendReceive 1 In this case only first eight bytes of send receive messages will be logged first four bytes contain the message type code and next for bytes contain the sequence number of message PasswordNotUsed As default the DAMATIC I O Server checks if the User Password is entered and if not then all writes to Damatic XD system are rejected The checking of User Password can be disabled by adding the following entry PasswordNotUsed 1 to the WIN INI file DAMATIC section DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 27 Troubleshooting menu The following debugging choices are appended to the Server s System Menu the menu which appears when you click the box in the upper left hand corner of the Server window Suspend Protocol Resume Protocol these choices permit you to turn protocol processing on and off what means that you can suspend access to the Damatic XD system Show Send if checked then all outgoing data contents of data packages sent from DAMATIC I O Server to Damatic XD system are displayed in hexadecimal format and saved in the log file Show Receive if checked then all incoming data contents of data packages received by DAMATIC I O Server from Damatic XD system are displayed in hexadecimal format and saved i
25. ick on Done when configuration for all Sockets has been performed Note If this is the first time the Sockets have been configured the user will be prompted to save configuration to an existing directory DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 10 Saving DAMATIC I O Server Configuration File If the configuration file does not currently exist or a new configuration path has been specified the Server will display the Save Configuration dialog box Save Configuration Configuration File Directory D DAMATICS Defaults IV Make this the default configuration file This dialog box displays the path where the Server is going to save the current configuration file The path may be changed if necessary Also the path can optionally be recorded in the WIN INI file by selecting the Make this the default configuration file option Doing so it will allow the DAMATIC I O Server to find the configuration file automatically each time it is started Configuration File Location When the DAMATIC Server starts up it first attempts to locate its configuration file by first checking the WIN INI file for a path that was previously specified If the path is not present in the WIN INI file the Server will assume that the current working directory is to be used To start the Server from an application directory configuration file other than the default configuration file a spe
26. identify the topic the DAMATIC I O Server will be accessing The Topic Name is an application specific sub group of data elements In the case of data coming from a DAMATIC I O Server program the topic name is the exact same name configured for the topic in the DAMATIC I O Server Note This will usually be the same as the Access Name although if desired they may be different However it must be the same name used when the topics were configured in section Configuring the DAMATIC I O Server Which protocol to use Select the protocol DDE or Suite Link that you are using When to advise server Select Advise all items if you want the Server program to poll for all data whether or not it is in visible windows alarmed logged trended or used in a script Selecting this option will impact performance therefore its use is not recommended Select Advise only active items if you want the Server program to poll only points in visible windows and points that are alarmed logged trended or used in any script Click OK to accept the new Access Name and close the Add Access Name dialog box The Access Names dialog box will reappear displaying the new Access Name selected in the list Click Close to close the Access Names dialog box Defining the Tag names To define the Tag names associated with the new Access Name invoke the Special Tagname Dictionary command in WindowMaker The Tagname Dictionary dialog box
27. initial value DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 23 CONNECTI ONS file When the Server is active at least one socket is opened all opened connections to names of XD variables are stored in the CONNECTI ONS file When the Server is shut down or connection with socket is closed when last topic belonging to this socket is deactivated all opened connections are still in CONNECTI ONS file So if some error occurs the Server is not shut down normally then all unreleased connections still remain in the CONNECTI ONS file When starting the Server next time or activating new connection with some socket before opening new connections at first all unreleased connections are read from CONNECTI ONS file and released GTW CIS reseted and wrong sequence ID errors If Error Code 2004 GTW CIS has been reseted is received from the GTW CIS when conversation between the Server and Damatic XD system is active then following message is logged to Wonderware Logger GTW CIS GTW CIS has been reseted All I O links must be re established and the Server starts to wait for re establishing of I O links Also if packet with wrong sequence ID is received from the GTW CIS then following message is logged Packet with wrong sequence ID received To restore communications all I O links must be re established and the Server starts to wait for re establishing of I O links To perform
28. n the log file Show Errors if checked then information about errors is displayed and saved in the log file Verbose if checked then additional debug information is displayed and saved in the log file This option can be used only for debugging purposes Dump if you click on this item then information about sockets topics messages and associated points will be displayed and saved in the log file All debug output is displayed via the Wonderware Logger which must be active for these commands to work Warning if you check Show Send and or Show Receive and or Verbose then debug output grows very fast DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 28 Errors The error displaying and logging in the DAMATIC I O Server depends on the type and importance of error Generally there are three types of error processing displaying the information about error in the Error Message Box displaying and logging the error information to Wonderware Logger and error logging to the Error Logging File Error Message Boxes The information about most important errors is displayed in the message box which appears on the top of computer screen Typically there are errors which inform that normal execution of the Server is impossible and immediately user action is needed e g Not enough memory for socket data structure Error logging to Wonderware Logger The Wonderware Logger program WWL
29. ogger must be active and Show Errors debugging choice must be checked in the Server s System Menu see Troubleshooting menu to display information about the Server run time errors in the WWLogger screen and to record error data to the WWLogger log file The first time the WWLogger program is started up each day by default it automatically creates a log file in the same directory in which it is installed unless the different directory is specified via the Options Disk Options The log files are named in the format YYMMDD AEH All information from Error Message Boxes also is logged to WWLogger Error Logging File The error logging file is a file with default name ERRORS DAT which will contain all error messages received from the Damatic XD system This file is updated by the Server if it becomes greater than 100 Kbytes or if included error messages are more than 1 week old The error logging file is filled depending on error codes received from the Damatic XD system The DAMATIC I O Server distribution disk contains the text file ERRMSGS TXT containing default error messages In this file special characters and amp are used for marking the start and end of error code e g 2001 amp if error code is 2001 The error logging file is filled in the following way If some non zero error code is received then the Server searches through file ERRMSGS TXT for matching error code If the matching error code is found then all text be
30. on entry expanded WIN INI entries ConnectionNameValueOK and ConnectionNameValueBad added Installation from CD information added WIN INI entries UseDamaticTime and ShortShowSendReceive added Processing of CONNECTI ONS file changed WIN INI entry NoZeroOnltemActivation 1 changed to default DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF
31. on IBM compatible computers connected via LAN or modem and DDE aware applications running on non PC based platforms under operating environments such as VMS and UNIX DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 2 SuiteLink uses a TCP IP based protocol and is designed by Wonderware specifically to meet industrial needs such as data integrity high throughput and easier diagnostics This protocol standard is only supported on Microsoft Windows NT 4 0 or higher SuiteLink is not a replacement for DDE FastDDE or NetDDE The protocol used between a client and a server depends on your network connections and configurations SuiteLink was designed to be the industrial data network distribution standard and provides the following features Value Time Quality VTQ places a time stamp and quality indicator on all data values delivered to VTQ aware clients Extensive diagnostics of the data throughput server loading computer resource consumption and network transport are made accessible through the Microsoft Windows NT operating system Performance Monitor This feature is critical for the scheme and maintenance of distributed industrial networks Consistent high data volumes can be maintained between applications regardless if the applications are on a single node or distributed over a large node count The network transport protocol is TCP IP using Microsoft s standard WinSock interfa
32. ot use a program that formats text such as MS Word unless the file is saved as DOS text The following is a typical entry for the DAMATIC I O Server DAMATIC Winlconic 0 WinFullScreen 0 WinTop 113 WinLeft 251 WinWidth 345 WinHeight 214 PortErrorRetries 3 SlowPollinterval 120 UseDamaticTime As default the DAMATIC I O Server uses the computer local time when delivering VTQ time stamping info to Wonderware clients e g InTouch and INSQL via the Suitelink protocol It is possible to use the time stamp info received from GTW CIS by adding the following entry to WIN INI file DAMATIC section UseDamaticTime 1 If there is no UseDamaticTime entry in WIN INI DAMATIC section or UseDamaticTime 0 then computer local time is used in VTQ info delivered to client applications SlowPolllnterval and PortErrorRetries The PortErrorRetries entry is used to enter the number of consecutive error retries for one socket If after PortErrorRetries the command still cannot be sent or still error response is received then this socket is changed to slow poll mode The WIN INI file SlowPolllnterval entry is used to enter the slow poll mode update interval in seconds The PortErrorRetries and SlowPollinterval also is used if GTW CIS is not replying to command sent from Server Then after PortErrorRetries attempts to receive the answer the Server starts to sleep between read attempts In this case the SlowPollinterval is used as a Sleep delay
33. r is received This entry should be used with care because in case if communication with GTW CIS is with delays it can freeze the data exchange between Server and GTW CIS NoZeroOnltemActivation As default the DAMATIC I O Server does not deliver any value for non string items to client application immediately after the item is activated This default seting is active if in WIN INI DAMATIC section there is following entry NoZeroOnltemActivation 1 or there is no NoZeroOnltemActivation entry in WIN INI DAMATIC section To deliver the value of 0 zero for non string items to client application immediately after the item is activated the following WIN INI DAMATIC section entry can be used NoZeroOnltemActivation 0 It is also possible to deliver any other initial value except 0 or 1 for non string items to client application immediately after the item is activated This can be done by entering the necessary initial value to NoZeroOnltemActivation entry for example the following string NoZeroOnltemActivation 99 will cause the initial value of 99 to be to delivered to client application immediately after the item is activated ConnectionNameValueOK and ConnectionNameValueBad Two special WIN INI DAMATIC section entries ConnectionNameValueOK and ConnectionNameValueBad can be used to determine the execution result of connection to Damatic XD variable name command As default the client application can determine the success
34. t 3 Secs Computer Internet Address or Name 1 39 74 54 113 GTW CIS Internet Address or Name 1 39 74 54 114 TCP IP Port Number 2051 4 Name of Error Logging File JERRORS DAT Cancel The following describes each dialog field in this dialog box Socket Name Enter the Socket name and later use it in the Topic Definition Only one Socket with same Computer Internet Address or Name GTW CIS Internet Address or Name and TCP IP Port Number can be defined so only one Socket can be defined for each GTW CIS Reply Timeout This field is used to enter the amount of time in seconds the GTW CIS will be given to reply to commands from the Server Computer Internet Address or Name Enter the Computer Internet Address IP Address or Name GTW CIS Internet Address or Name This field is used to enter the GTW CIS Internet Address IP Address or Name TCP IP Port Number This field is used to enter the GTW CIS TCP IP port number Name of Error Logging File This field is used to enter the name of file which will contain all error messages received from the Damatic XD system The default name is ERRORS DAT This file is updated if it becomes greater than 100 Kbytes or if included error messages are more than 1 week old If this field is empty then no error logging is performed Once all entries have been made click on OK to process the configuration for the Socket The DAMATIC Socket Settings first dialog box will appear again Cl
35. t with the topic Additional topics may be associated with the same Socket at a later time DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 12 5 Set the Type of Status for this topic This field is used to enter the interpretation type of status failbits received from the Damatic XD system The possible selections are text default or numeric 6 Set the Update Interval field to indicate the frequency in configurable units milliseconds seconds minutes hours at which the values of items will be read polled from the Damatic XD system The default value is 3 seconds The Update Interval must be greater than the Damatic XD system internal cycle time 7 Enter the Internal Cycle Time value This field is used to enter the Damatic XD system internal cycle time the frequency at which the data is updated from Process Stations PCS to CIS memory The possible values are from 100 milliseconds to 25 seconds the default value is 2000 milliseconds It is not recommended that this value is less than 500 milliseconds Once all entries have been made click on OK to process the configuration for the Topic The Topic definition dialog box will appear again Select Done when configuration for all Topics has been performed Item Names The Damatic I O Server supports following types of tags items Discrete Boolean Integer 32 bits Real floating point and Message string used onl
36. tting of type of the status of values for Topic if the type of the status of values is numeric then type of item type is Integer and it contains return value in binary format if the type of the status of values is text then type of item type is Message and it contains character string with the combination of received fault bits in text format e g if there is no error then this character string is empty or if bits b1 b3 and b4 are set to 1 then this string will contain ext dis inv 2 Vor v used only for items which are whole vectors and the vector notation is not included in the item name e g r e pr lic100 v 3 W or w used for items which are used for writing to preconfigured table indexes because the same index value can be used in read and write blocks therefore indexes are divided in two groups Read Only indexes e g r 1 and Write Only indexes e g r 1 w items which are used for writing directly to name without creating connection to name these items are Write Only they are not polled for example the item r e pr 4XISS5SANA4 w can be used to write new values to Damatic XD variable e pr 4XISS5ANA4 without creating connection to this variable If the item name contains the notation for table information elem with some digits and minus sign included inside brackets then this item is processed as a vector array or an element of vector For example I e pr lic100 elem 1
37. tween this error code amp character and next character is added to the error logging file If no matching error code is found then ERRMSGS TXT last message lu Unexpected ERROR received is added to the error logging file where lu is converted to received error number The file ERRMSGS TXT is only a template and can be freely modified Only the end part of this file last three messages starting from error code 9998 amp must remain unchanged To ease the maintenance of the error logging file the Server adds special character 0x02 and date and time in the format MM DD YY HH MM SS before each error message which is written to the error logging file DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 29 Feb 95 Mar 95 Nov 96 Nov 97 Feb 98 Nov 98 Dec 98 Mar 2000 Mar 2000 Mar 2002 Mar 2003 Rev 1 0 Rev 1 1 Rev 2 0 Rev 2 1 Rev 2 2 Rev 2 3 Rev 2 4 Rev 2 5 Rev 2 6 Rev 2 7 Rev 2 8 KLINKMANN AUTOMATION DAMATIC I O Server Revision History First Release Additions to Troubleshooting section Interface changed to WinSockets NT support added Minor changes Write only to name added Additions to Troubleshooting section NOF_PENDING_WRITES DDE item added Suite Link support added User manual layout changed Modifications in the manual text Installing the DAMATIC I O Server section changed KEEPALIVE item added The NoZeroOnltemActivati
38. will appear DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 17 Tagname Dictionary EE x C Main Details Alarms Details amp Alarms Members Hew Restore Delete Save KK elect gt gt Cancel Tagname fizxiS5INTS2 Type o Integer Group SSystem Readonly Read Write Comment I LogData IF Log Events I Retentive Value I Retentive Parameters Click on New and enter the Tagname The tagname defined here is the name InTouch will use The DAMATIC I O Server does not see this name Select the tag type by clicking on the Type button The Tag Types dialog box will appear Memory Discrete 170 Discrete Indirect Discrete Memory Integer 170 Integer Memory Real 170 Real Indirect Analog Memory Message 170 Message Indirect Message Group Var Hist Trend Tag ID To access DAMATIC items the type must be I O Discrete I O Integer I O Real or I O Message Select the Tag type The Details dialog box for the tag name will appear DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 18 Initial Value jo Min EU 32768 Mag EU 132767 Deadband jo Min Raw 1 32769 Max Raw 32767 l EEE Conversion Eng Units f Linear Unassigned Square Root Item I Use Tagname as Item Name Log Deadband fo Select the Access name for DAMATIC I O Server by
39. y for fault status Integer and Real Read Only arrays vectors are supported but if Damatic XD variable is an element of vector then it is Read Write i e it is possible to write into the vector element Each item has its unique name maximum length of name is 67 characters and first character of name must be a letter The Server supports reading writing data from to to the Damatic XD system both by means of configured table indexes and by names of Damatic XD variables The item name generally may be described as P item name 1 S where item name Damatic XD index or variable name which always must be included in the maximum length of item name is 63 characters P item name prefix e g one character before first and represents item type dor D Discrete i or I Integer ror R Real 1 optionally used item name suffix for one time request indication in this case the item name must be Damatic XD variable name index is not allowed and no connection to name will be opened the item value will be read only once by cnp_read_value_of_name function DAMATIC I O Server Ver 2 x User Manual Rev 2 8 090XXM28 PDF Klinkmann Automation DAMATIC I O Server 13 S item name suffix possible values are 1 F or f used only for items which corresponds to fault status return value from XD LINK library s functions cnp_get_rr_buf_data or cnp_vect_fails the type of these Read Only items depends on the current se

Download Pdf Manuals

image

Related Search

Related Contents

Using Your Klic-N-Kut for Rhinestone Applications1  Vakuum-Pumpe KNF 035  TX9165 - Sentro 8 Sensorstation - User Manual  Samsung SF-560R multifunctional  Descargar Ficha técnica  MODE D`EMPLOI DÉTAILLÉ  Casio EX-S7 User's Manual  Consultez le guide du tri  Manual de Instrução e operações  Réglage des culbuteurs  