1. he can call the alarm panel After getting through the call user will hear a long en ite beep Then press remote control password default 123456 and to enter listen in status User can hear the sound around the alarm panel If the password is input wrong there will be three short beeps while a long beep means correct A long beep means password is correct while three short beeps mean wrong you need to input again If the password is wrong for consecutive three times the call will be hung up automatically If there s no input within 30seconds after getting through the call it will also be hung up automatically Operation by SMS User can send sms to remotely arm or disarm the system Arm remote control password default 123456 1 Disarm remote control password default 123456 2 Vi Technical Parameters Power DC12V 1 2A Status current lt 30mA GSM bands 850 900 1800 1900MHz Wireless receiving frequency 433MHz 0 5MHz Receiving code ASK Wireless distance no obstacle 80m Working temperature 10 45 C Working humidity lt 90 Backup battery 7 4V 500mAh 12 Vil Standard Kit Alarm panel 1pc Power adaptor 1pc User manual 1pc VIII Additional Accessories Signal Repeater Glass Sensor Smoke Detector Wireless Keypad Panic Button law SZ Gas Detector e Wireless Outdoor Flash Siren Remote Controller Wireless Pet Immune PIR Detector Optional senso
2. 0 Note a Power failure recovery alert after activating this function when the external power supply is off user will receive a message POWER DOWN If the power recovers after failure the message is POWER UP b Alarm call circle time when there s nobody answers the alarm call the device will call all the alarm phone numbers in circle automatically This is to set the circle time 4 Settings by SMS Use your mobile phone to send a message to the number of the device All the above settings in Table 1 can also be set by SMS And they should begin with operation password The default password is 888888 For example 1 888888 30 112233 change the remote control password into 112233 2 888888 52 13412345678 set the third alarm call number as 13412345678 3 888888 01 0 turn off the function of SMS alert for power failure 4 888888 02 5 set the alarm call circle as 5 times All the following commands in Table 2 can also be set by SMS The SMS should begin with operation password The default password is 888888 Table 2 Change alarm message of SOS button on main panel 96 message content Message content should not exceed 25 English letters Default SMS 00 Emergency ALARM Change alarm message of wireless panic button 91 95 message content 91 the 1st wireless sensor 92 the 2nd wireless sensor 95 the 5th wireless sensor M
3. GSM Emergency Alarm System sTATUs POWER MONITOR 1 ARM Ca a Ae SOS bod DISARM User Manual Profile For a better understanding of this product please read this user manual thoroughly before using it Il 1 Features Adopt GSM 850 900 1800 1900 bands can be used all over the world Can per set 5 phone numbers when there is an alarm it will call these numbers in order Press DISARM button on the main panel it will stop alarming Can per set 5 SMS numbers when there is an alarm it will send SMS to these numbers Maximum 30 wireless sensors including wireless panic button or remote controllers etc 2 wired ports to connect wired sensors The SMS content of the first 5 wireless sensors can be edited by users Support remote listen in and two way communication connect an external speaker SMS alert for power failure or recovery Built in backup rechargeable battery to keep working after power off Preparation before use Insert SIM card in alarm system Before inserting SIM card please make sure Use a regular mobile phone to set PIN code request to off Delete all stored numbers Make sure there s enough balance in the card to work normally Open the outside case of the alarm system and put the SIM card into the card slot see picture SIM card 2 Connect all devices needed a Connect the antenna Screw the antenna to the unit carefully do not over tight
4. en the screw or leave it too loose b Connect the alarm siren optional c Connect the two way intercom speaker optional d Connect wired sensors optional 3 Power Plug in the power adaptor and turn on the backup battery switch The LED indicator will flash and the unit enters standby status 4 Do the needed settings check Part System Settings in detail Ill Host 1 LED status explanation LED LED Status System working status Hasn t turned on the switch hasn t Off connected the power no power in built in POWER battery Red power supply is normal Red flash quickly Check SIM card and search GSM network SIM card and GSM signal are normal have Green flash slowly stored numbers in SIM card in arm status STATUS Red In coding status wait to set sensors Green flash quickly Sensor is set successfully Red and Green flash Receive correct setting SMS alternately Listen in status users can hear the voice MONITOR On from the scene ALARM On Alarming status 2 Host panel MIC SOS button Disarm Status indicator Reset External power Wired port 2 GND Wired port 1 GND W Om HAA e S Siren eoeoevee GND Speake ES SPK Negative of two way intercom speaker black cable SPK Positive of two way intercom speaker red cable IN2 Wired sensor GND GND IN1 Wired sens
5. essage content should not exceed 25 English letters Default SMS XX Emergency ALARM XX means the serial number of wireless sensor Delete alarm message 91 95 Note After successful setting user will receive a SMS reply with the content of OK If the SMS setting format is wrong user will receive FORMAT ERROR 5 Factory reset 10 Press the RESET button for 5 seconds until the LEDs on the panel are flashing quickly After this operation all the settings return to factory default V Operation Instruction 1 Answer alarm call When there is an alarm the ALARM LED on the panel will be on and the external siren if user has connected will ring for 3 minutes if there s no operation Also the device will send alarm SMS to and call the preset numbers Press DISARM button on the main panel or the remote controller it will stop the alarm The alarm system will keep calling all the preset numbers in order if nobody answers the call The default circle time is 3 If someone answers the call it will enter two way intercom status automatically and the siren stops ringing Then user can press 1 to arm 2 to disarm 3 to listen in and 4 to return to intercom A long beep means correct operation and three short beeps means wrong operation 2 Remote control operation Operation by remote call When users are outside and want to monitor the alarm system
6. or GND GND OUT Positive of siren red cable GND Negative of siren black cable IV System Settings This device has two passwords Remote control password used for remote listen in and two way intercom Default 123456 Operation password used for system settings Default 888888 Note These two passwords could not be set as the same 1 Coding of wireless sensors This device supports maximum 30pcs wireless sensors Press the reset button at the back side of the panel there will be a shot beep and the STATUS LED will be on red indicating the device enters coding status Trigger the wireless sensor you want to code there will be along beep and the STATUS LED will flash in green The sensor is set successfully The sensors will be numbered in consecutive order automatically according to the coding sequence That means the first panic button coded is No 1 the second is No 2 and the like The default alarm SMS is xx Emergency ALARM xx means the serial number of the sensor If the sensor quantity exceeds 30pcs the exceeded sensor will replace the coded one from No 1 2 Exit coding In coding status press RESET button again Or if there s no operation within 5seconds after entering coding status it will exit coding automatically 3 Settings by call Users can use a mobile phone or fixed line telephone to call the number of the host to set alarm call numbers It can store maximum 5 numbers After
7. rs detectors are packed separately You can choose according to your specific requirements 13 IX Care and Maintenance The alarm system has excellent design and uses advanced technologies It shall be used with care The following suggestions are required to maintain your obligations under the warranty terms and for prolonging the service life of the system lt gt lt gt Place the control panel and all parts and accessories out of children s reach Keep the alarm system dry Rain humidity and various fluids or moisture all will corrupt the electronic circuit Do not use or place the alarm system in dirty locations otherwise the electronic elements will be damaged Do no place the system in excessively hot locations High temperature will shorten the service life of electronic equipment damage batteries deform or even melt some plastic parts Do not place the system in excessively cold locations Otherwise condensation many occur and damage the circuit board of the alarm system It is recommended that you check and test the alarm system periodically Check the main unit every three months 1 2 3 4 Whether it can arm disarm normally Whether it can dial the number for alarm normally Whether it can receive wireless detectors signal normally Whether the back up battery can work normally Check the wireless detectors if you have once a month 1 Trigger wireless detectors to see if s
8. se send it 15 to the dealer or authorized service point for repair We will try our best to solve the problem for you as soon as possible 16
9. setting the host will call these numbers when alarm Setting method after getting through the call users will hear a long beep Then press operation password default 888888 and A long beep means password is correct Three short beeps mean password is wrong you need to input again If the password is wrong for consecutive three times the call will be hung up automatically If there s no input within 30seconds after getting through the call it will also be hung up automatically After password and users can do the following settings Table 1 Function setting Setting format Change remote control 30 new password Password should password be 6 digit Default 123456 Change operation 31 new password Password should Py password be 6 digit Default 888888 Alarm call number setting Delete call number Alarm SMS number setting 50 54 number 50 54 55 59 number 50 the 1st number 51 the 2nd number 54 the 5th number Number should not exceed 20 digit 55 the 1st SMS number 56 the 2nd number 59 the 5th number Number should not exceed 20 digit Delete SMS number 55 59 Turn on power LED OO 1 Default on Turn off power LED 00 0 Power failure recovery 014 1 ON Default on alert 01 0 OFF Alarm call circle time 02 1 9 Default 3 Siren rings when alarm 03 1 Default on Siren off when alarm O3
10. ystem can alarm normally 14 2 Check all detectors batteries to see if it s in low voltage 3 Check whether wireless detectors can send signal to the main unit normally Check the SIM card 1 Check the use of SIM card such as network signal balance etc 2 Make sure the PIN code verification of the SIM card is closed 3 Please keep the password and SIM card number safe in case that other people remote control the system illegally Since the alarm system is continuously in operation or standby mode the supply adaptor of the control panel shall be connected to a safe and reliable socket lt Do not place the system near your bedroom or office table because the siren will make high loudness sound in the case of alarm which may adversely affect your rest or work lt If the alarm system will not be used for a long time please disconnect the system from the power supply lt Please do not disassemble repair and alter the products without permission or it may cause accidents and faults lt Do not drop this product on the ground or on hard objects as it may lead to massive impact to cause faults and damages lt Without approval and consent of relevant authorities please do not set 110 119 or the alarm phone number of police station for this main unit Please read the suggestions above carefully and follow the instructions herein If any of the equipment does not work properly plea