Installationsanweisung / Installation Instructions
Contents
1. The following symbol indicates specific danger conditions which could result in damage to equipment or personal injury up to the death of the operator Risk of electric shock Target Group All installation works at the automation system must be performed only by trained per sonnel e g qualified electrical employees electrical engineers The installation staff must have an education which entitles to interventions at the auto mation system Unpacking Unpack all parts carefully and check the contents for visible damages in transit Also check whether the delivery agrees with the details on the delivery note If you notice damages in transit or discrepancies please immediately contact our sales department Mounting It is possible to mount the device fast and simple from the rear side The mounting into switchboards with a plate strength of approx 1 to 8 mm is possible When installing take care to leave a gap of at least 30 mm to ensure sufficient air circu lation To ensure that the front side meets the declared degree of protection make sure that the seal is even with the mounting surface and the hexagonal nuts are uniformly screwed on 1 Push the device from in front through the mounting hole 2 Screw the device with the hexagonal nuts from the accessories kit Connecting Supply Voltage The supply voltage is connected via the connector X1 The unit is equipped with a reverse voltage protection If the pola
2. 0 06 L LGGl ww 00 OP 786 5 ww 00 291 196 00 mm 7 717 204 00 mm 8 031 220 00 mm 8 661 Montageausschnitt Panel cutout Frontplatte Front panel A B
3. Steckerbelegung X1 Versorgungsspannung Bezeichnung union Fremdspannungsarme Erde Versorgungsspannung 0 V Versorgungsspannung 24 VDC Die geeignete Buchsenleiste vom Typ Phoenix COMBICON MSTB 2 5 3 STF ist im Lie ferumfang enthalten Sie k nnen Kabel mit feindr htigen Adern bis 2 5 mm Querschnitt verwenden In elektrischen Anlagen k nnen f r Menschen gef hrliche Spannungen auftreten Bei Ber hrung von Spannungsf hrenden Teilen besteht die Gefahr eines Stromschlags Beim Anschluss des Ger ts an die Versorgungsspannung gehen Sie wie folgt vor 1 Isolieren Sie den Au enmantel der Leitung ca 30 mm und die Adern ca 5 mm ab 5 mm 3 bag e Kabel konfektionieren 2 Versehen Sie die Adern mit Aderendh lsen und schlie en Sie die Adern an den Steckverbinder an 400 Li Buchsenleiste anschlie en Falls Sie geschirmte Anschlusskabel im Bereich der Versorgungsspannung verwenden dann sollten Sie die Schirmung mit Pin 1 verbinden 3 Stecken Sie die Buchsenleiste auf den Stecker X1 2 410 YANO ei Buchsenleiste aufstecken 4 Sichern Sie die Buchsenleiste durch die Schraubverriegelung gegen herausrut schen F r die Schutzerdung am Gewindebolzen m ssen Sie in jedem Fall eine getrennte Lei tung vorsehen Die Leitung muss einen Mindestquerschnitt von 1 5 mm aufweisen und so kurz wie m glich ausgef hrt sein Dadurch erh ht sich die Betriebssicherheit Standard und Feldbusschnitt
4. Touch Panel TP22 S tron electronic GmbH Kurze Stra e 29 70794 Filderstadt Tel 49 7 11 770980 Fax 49 7 11 77 09 86 0 E Mail doku suetron de Internet www suetron de INSTALLATIONSANWEISUNG INSTALLATION INSTRUCTIONS TP22_IS_V1 1 0 18 01 2002 Copyright by S tron electronic GmbH Deutsch 80860 007 D SUTRON ELECTRONIC GMBH Symbole In diesem Handbuch werden Symbole verwendet um Sie auf Hinweise und Gefahren aufmerksam zu machen Gefahr Dieses Symbol wird benutzt wenn es durch ungenaues Befolgen oder Nichtbefolgen von Anweisungen zu Personensch den kommen kann Hinweis Dieses Symbol kennzeichnet Anwendungsratschl ge oder erg nzende Hinweise Das nachfolgende Symbol kennzeichnet spezifische Gefahrenzust nde die zu Maschi nen und Personensch den bis hin zum Tod des Bedieners f hren k nnen Gefahr durch elektrische Spannung Zielgruppe Alle Installationsarbeiten in Verbindung mit dem Automatisierungssystem d rfen nur von geschultem Personal ausgef hrt werden z B Elektrofachkr fte Elektroingenieure Das Installationspersonal muss eine Ausbildung besitzen die zu Eingriffen am Automa tisierungssystem berechtigt Auspacken Packen Sie alle Teile sorgf ltig aus und berpr fen Sie den Inhalt auf sichtbare Trans portsch den berpr fen Sie ebenfalls ob die Lieferung mit den Angaben auf dem Lie ferschein bereinstimmt Wenn Sie Transportsch den oder Unstimmigkeite
5. n feststellen setzen Sie sich bitte un verz glich mit unserer Verkaufsabteilung in Verbindung Montage Das Ger t erm glicht Ihnen eine schnelle und einfache Montage von der Ger ter ck seite Vorzugsweise wurde hier an den Einbau in Schalttafeln mit einer Blechst rke von ca 1 bis 8 mm gedacht Beim Einbau m ssen Sie umlaufend einen Freiraum von mindestens 30 mm ber cksich tigen um eine ausreichende Luftzirkulation zu gew hrleisten Um die angegebene Schutzart zu gew hrleisten m ssen Sie darauf achten dass die Dichtung eben auf der Einbaufl che aufliegt und die Sechskantmuttern gleichm ig an gezogen sind 1 Schieben Sie das Ger t von vorne durch den Montageausschnitt 2 Befestigen Sie das Ger t mit den Sechskantmuttern des Zubeh rsatzes Deutsch Ca Anschlie en Versorgungsspannung Die Versorgungsspannung wird ber den Steckverbinder X1 zugef hrt Das Ger t verf gt ber einen Verpolungsschutz Bei falscher Polung wird das Ger t nicht in Betrieb gesetzt Dieses Ger t ist ein Betriebsmittel der Schutzklasse I F r einen sicheren Betrieb m s sen Sie eine Schutzkleinspannung SELV entsprechend DIN EN 61131 f r die Versor gungsspannung verwenden Elektrische Daten Versorgungsspannung 24 V DC SELV entsprechend DIN EN 61131 Restwelligkeit Maximal 10 Mindestspannung 19 2 V Maximalspannung 30 2 V Steckverbinder im Terminal 3 poliger Steckverbinder Phoenix COMBICON MSTBV 2 5 3 GF
6. ng loose A separate cable must always be provided for the protective grounding at the threaded bolt The cable must have a minimum diameter of 1 5 mm and be as short as possible Complying with this recommendation will increase operational safety Standard and Field Bus Interfaces The pin assignment of the interfaces can be found on the rear side of the device or in the product specific user manual User Mode Switch The user mode switch is positioned at the rear side of the device User mode switch Standard mode with PLC delivery state EAE Standard mode without PLC ES Transparent mode with start and stop code of the keys mag Transparent mode without stop code of the keys Activate download deletes application memory and default con Pe trast setting BD EA EU DET Legend of table Switch ON Switch OFF X Any switch position Shielding D SUB Connectors You must shield the D SUB connectors as follows 4 570 1 2 3 4 Shielding of D SUB connectors 1 D SUB connector 2 Shield 3 Cable clamp 4 Cable The shield must be pushed back over a large surface of the cable sheath By fastening the cable with the cord grip you have to ensure an electrical contact of the shield to the housing over an area as wide as possible and an appropriate strain relief Olrt N N T E ei St Q T RE LERG E WW 0
7. rity is not correct the unit does not operate This unit conforms to the safety class I For safe operation it is necessary to use safety extra low voltage SELV in accordance with DIN EN 61131 for the supply voltage Electrical data Supply voltage 24 V DC SELV according to DIN EN 61131 Residual ripple 10 maximum Minimum voltage 19 2 V Maximum voltage 30 2 V Connector in the terminal 3 pin connector Phoenix COMBICON MSTBV 2 5 3 GF Pin assignment X1 supply voltage Pin Designation 2 24 VDC Supply voltage 24 VDC The suitable female connector Phoenix COMBICON MSTB 2 5 3 STF is supplied You can use cables with fine strands and a cross section of up to 2 5mm Hazardous voltages can exist inside electrical installations that can pose a danger to hu mans Coming in contact with live parts may result in electric shock English With the connection of the device to the supply voltage you proceed as follows 1 Strip approx 30 mm off the outer cable sheath and approx 5 mm off the strands ke be n Prepare cables 2 Fit the strands with ferrules and connect the strands to the connector 400 D Connect female connector If shielded connecting cables are used for the supply voltage the shield should be con nected to pin 1 3 Plug the female connector on connector X1 2 410 Plugging female connector on X1 4 Use the screw locking system of the female connector to prevent it from comi
8. stellen Die Anschlussbelegung der Schnittstellen finden Sie auf der Ger ter ckseite oder im Produktspezifischen Anwenderhandbuch Betriebsartenschalter Der Betriebsartenschalter ist auf der R ckseite des Ger tes angebracht Betriebsartenschalter Sppe ITT eraran mises Tezen ll eemeenegg TTT ersparen Mode mi Siart egener EES EEN Transparent Mode ohne Stopcode der Tasten Download aktivieren l scht den Applikationsspeicher und Grund Pt kontrasteinstellung RER Legende zur Tabelle Schalter ON Schalter OFF X Schalterstellung beliebig Be O o 2 gt m English gt gt gt Schirmung von D SUB Steckverbindungen Die D SUB Steckverbindungen m ssen folgenderma en geschirmt werden em 570 1 2 3 4 Schirmung von D SUB Steckverbindungen 1 D SUB Steckverbinder 2 Schirm 3 Kabelschelle 4 Kabel Der Schirm muss fl chig ber den Kabelmantel zur ckgeschlagen werden Durch die Befestigung mit der Kabelschelle muss gleichzeitig ein gro fl chiger Kontakt vom Schirm zum Geh use entstehen und eine ausreichende Zugentlastung gew hrleis tet werden Symbols The symbols in this manual are used to draw your attention on notes and dangers Danger This symbol refers to an operating procedure which if not carefully followed could result in personal injury Note This symbol indicates application tips or supplementary notes