Home
TAINY GMOD - Dr. Neuhaus Telekommunikation GmbH
Contents
1. Create this connection sessseseeesseccsssessseseseey C Only for myself lt Back Cancel 1 Specify who is allowed to use the connection 2 Click on Next gt 5 You may be asked to activate the shared use of the internet connection In this case select your appropriate setting Click on Next gt Windows 2000 6 Dial up connection Network Connection Wizard Finished The wizard is ready to create your Connection Type a name you want for this connection Dr Neuhaus TAINY GMOD Service Click Finish to save it in the Network Connections Folder To edit this connection later select it click the File menu the connection and then click Properties Enter a name for 1 Enter a name for the connection Dr Neuhaus TAINY GMOD Sx Service 2 Click on Finish gt 28 von 84 TAINY GMOD Sx Windows 2000 Install the configuration program TAINY GMOD SxConfig TAINY GMOD Sx Putting the Device Into Operation The dial up connection for service of the TAINY GMOD Sx has now been created The connection is now listed in the Network and Dial Up connections dialog Close the dialog and continue File Installation of the TAINY GMOD Sx Configuration software 3 3 Installing the TAINY GMOD Sx Configuration software OK Skip ESRSSSBRRDERRRRRRENARRRARARAANNERRAREENER Click on OK to install the configuration program TAINY GMOD SxConfig Follow the i
2. rina s Application tab Specify how the TAINY GMOD Sx shall react to the application connected to its COM port Furthermore define if the TAINY GMOD Sx shall answer incoming calls which shall be routed to the application connected to the COM interface automatically auto answer See also configuration tab CSD Transparent page 55 For TAINY GMOD S2 Specify how the device shall communicate with the application connected to its interface COM2 Parameter Explanation configuration options COM BAUDRATE Baud rate Default setting 57600 This defines the speed with which the TAINY GMOD Sx communicates with the application e g machine sensor device connected to its COM port Permissible values 300 1200 2400 4800 9600 19200 38400 and 57600 If you want to change the value use the selection list The value set here must match the speed with which the connected application can communicate 46 von 84 TAINY GMOD Sx Configuring the TAINY GMOD Sx Parameter Explanation configuration options COM FORMAT CGharacteriormat cotta iti t tion hatte as ert EL chelate Nate id Default 8N1 8 data bits non parity 1 stop bit Defines the character format with which the TAINY GMOD Sx communicates with the application connected to its COM port Permissible values 7N1 8E1 7E1 801 701 8N2 7N2 8E2 7E2 802 702 8N1 If you want to change the value use the selection list The character format defined here
3. CLIP of remote stations from which TAINY GMOD Sx will accept incoming GSM data calls for remote 59 von 84 Configuring the TAINY GMOD Sx Parameter Explanation configuration options service Permissible values max 30 characters digits O to 9 denotes that all incoming GSM data calls are accepted as service calls TAINY GMOD Sx first checks if an incoming GSM data call is admissible for remote service Only if the remote station is not specified for service access does it check if the call is permissible for the COM interface Therefore please make sure that phone numbers specified for COM access have not already been configured for service access and vice versa If you specify Star as remote service phone number no GSM data call is routed to the COM interface for data transfer with the application All incoming GSM data calls are then interpreted as service calls GSM data calls for remote service differ from those specified in CSD Transparent For remote service of the TAINY GMOD Sx the data are exchanged packet oriented via the GSM network or GSM PSTN using the TCP IP protocol When using a remote station with Windows operating system the dial up network connection has to be used for service calls also see PPP Point to point protocol in the section Glossary An existing GPRS connection i e to the TAINY SwitchingCenter will be interrupted when a GSM data call comes in Afterwards the GPRS con
4. In Leased line mode LL incoming calls for the COM interface are always answered automatically If DTR is selected for Control in connection mode Leased line LL the DTR signal has to be active Instead of activating auto answer incoming calls can be accepted as follows The application connected to the COM TAINY GMOD Sx Parameter COM2 BAUDRATE COM2 FORMAT TAINY GMOD Sx Configuring the TAINY GMOD Sx Explanation configuration options interface answers the call with the command ATA see COM interface AT commands supported in CS mode page 78 This requires that the TAINY GMOD Sx be set to Dial up connection mode CS see page 42 An existing GPRS connection i e to the TAINY SwitchingCenter will be interrupted when a GSM data call comes in Afterwards the GPRS connection will be restored if TAINY GMOD Sx is set to Leased line mode LL If DTRis selected for Control in connection mode Leased line LL the DTR signal has to be active TAINY GMOD S2 The following parameters only apply for the TAINY GMOD S2 Furthermore they are only active if the device is configured such that incoming GSM data calls shall be routed to COM2 see configuration tab CSD Transparent page 55 Default 57600 Defines the speed with which the TAINY GMOD S2 communicates with the application connected to its interface COM2 Permissible values 300 1200 2400 4800 9600 19200 38400 und 57600 If you want t
5. New Connection Wizard Phone Number to Dial What is the phone number you will use to make this connection Type the phone number below Phone number 98H You might need to include a 1 or the area code or both If you are not sure you need the extra numbers dial the phone number on your telephone If you hear a modem sound the number dialed is correct Enter the following number 98 asterisk 98 hash symbol Then click on Next gt TAINY GMOD Sx Enter a name for the connection TAINY GMOD Service Windows XP Install the configuration program TAINY GMOD SxConfig TAINY GMOD Sx Putting the Device Into Operation New Connection Wizard Finished The wizard is ready to create your connection Type a name you want for this connection SIN GMOD Service Click Finish to save it in the Network Connections folder To edit this connection later select it click the File menu and then click Properties Finish Enter a name for the connection e g TAINY GMOD Service 5 When you click on Finish you end the process of creating the dial up connection The dial up connection for service of the TAINY GMOD Sx has now been created The connection is now listed in the Network Connections dialog Close the dialog and continue File Installation of the TAIN GMOD Sx Configuration software 3 3 Installing the TAINY GMOD Sx Configuration software OK Skip ERRSENRASSNN
6. recognised worldwide It must be absolutely correct Access Point Name APN Name of the access point to the Internet Intranet New user hameau ve ion es et tu When the TAINY GMOD Sx establishes a connection into the GPRS network it is normally asked for the user name and password to gain access to the network Some GSM GPRS network operators do not implement access control using a user name and or password In this case do not set these parameters Permissible characters for user name and password all letters and digits no spaces no special characters max 30 characters Domain Name Server 1 and 2 You must only enter the DNS addresses if the address of the server which the TAINY GMOD Sx connects to the TAINY SwitchingCenter ModemServer or the TAINY ComPortServer is given as the host name URL on the page Connection see page 42 Standard 99 1 Dial string to dial into the GPRS network Normally it is always 99 1 41 von 84 Configuring the TAINY GMOD Sx GPRS Connection Application CSD Fallback CSD Transparent Service PIN Other Properties Connection tab Parameter IP_CONFIG IP 42 von 84 TAINY GMOD Sx Configuration software Connection File Parameters Logfile New firmware Options Info Login Information Destination address D Destination port number 26862 te wou f Select local port number automatically Connection attempts 5 Device name Device password h
7. the service PC Start it as follows insofar as the specifications have been taken over during installation of this program In the Start menu select Programs Neuhaus TAINY GMOD Sx TAINY GMOD SxConfig 3 In the Log file menu click on View log file Effect The configuration program loads the log file from the TAINY GMOD Sx into the PC and displays the set parameters 4 Switch the TAINY GMOD Sx back to normal operating application mode by again pressing the service button longer than 1 second max 3 seconds You can also view the statistics of all GPRS connections To do this please refer to the chapter Displaying Device and Status Information TAINY GMOD Sx 71 von 84 Displaying Device and Status Information 9 Displaying Device and Status Information Viewing device Prerequisites information and e The configuration program TAINY GMOD SxConfig is installed connection on the PC which you wish to use for this purpose statistics using GPRS Proceed as follows RS232ConfigTSC 1 Connect the service PC to the TAINY GMOD Sx Switch the TAINY GMOD Sx to service mode by pressing the service button longer than 1 second max 3 seconds 2 Execute the configuration program TAINY GMOD SxConfig on the service PC Start it as follows insofar as the specifications have been taken over during installation of this program In the Start menu select Programs Neuhaus TAINY GMOD Sx TAINY GMOD SxConfig 3 Click on View GMOD Sx
8. Into Operation Windows 2000 4 The next dialog allows you to install a driver manually cAI NN LANON Install New Modem it SG Select the manufacturer and model of your modem If your modem is not listed or if you fre have an installation disk click Have Disk Manufacturers Models Standard Modem Types Communications cable between two computers Standard 300 bps Modem Standard 1200 bps Modem Standard 2400 bps Modem Standard 9600 bps Modem Standard 14400 bps Modem Chandard 10900 hne hdederm Have Disk lt Back Cancel Click on the Have disk button 5 In the dialog which follows 1 Click on Browse 2 Switch to the Drivers folder on the inserted CD to install the driver file TAINY_GMODService INF from there 6 When prompted to select the model select Dr Neuhaus TAINY GMOD Service Then click on Next gt Click on Have Disk 7 The dialog for selecting the connection appears Add Remove Hardware Wizard Install New Modem Select the portis you want to install the modem on You have selected the following modem Dr Neuhaus TAINY GMOD Service On which ports do you want to install t All ports Selected ports COM2 Select the COM port lt Back Cancel 1 Select the COM port to which you have connected the cable to the service interface of the TAINY GMOD Sx 2 Click on Next gt TAINY GMOD Sx 25 von 84 Putting the D
9. Service Mode a dial up networking connection is required Click on the button marked OK to install the dial up networking connection now OK Skip PECANTATAEATAANA0ANAANANAA A AN Click on OK to create the necessary dial up connection in which the connection data will be stored 1 The New Connection Wizard is started New Connection Wizard Type of Connection Select the type of the connection Connect using my phone line modem or ISDN Connect to a private network through the Internet Create a Virtual Private Network VPN connection or tunnel through the internet Connect directly to another computer Connect using my serial parallel or infrared port Connect to the network via broadband Connect through my broadband connection 1 Select the option Dial up to private network 2 Click on Next gt 33 von 84 Putting the Device Into Operation Windows XP Create the dial up connection Dr Neuhaus TAINY GMOD Service auswahlen 34 von 84 2 You may be asked to select the desired device modem New Connection Wizard Select a Device emn This is the device that will be used to make the connection as You have more than one dial up device on your computer Select the devices to use in this connection Ta Modem Dr Neuhaus TAINY GMOD Service COM CS Modem Standard 19200 bps Modem COM2 Cancel In the list of modems select Dr Neuhaus TAINY GMOD Service
10. Status Information section on page 73 Updating the Prerequisites firmware e The configuration program TAINY GMOD SxConfig is installed on the PC which you wish to use to update the firmware e The firmware file is on the service PC Proceed as follows 1 Connect the service PC to the TAINY GMOD Sx Switch the TAINY GMOD Sx by pressing the service button longer than 1 second max 3 seconds 2 Execute the configuration program TAINY GMOD SxConfig on the service PC Start it as follows insofar as the specifications have been taken over during installation of this program In the Start menu select Programs Neuhaus TAINY GMOD Sx TAINY GMOD SxConfig 3 Inthe New firmware menu click on Store new firmware into GPRS RS232 Select the firmware file stored on your computer to transfer it into the TAINY GMOD Sx The transfer process can take several minutes 76 von 84 TAINY GMOD Sx Loading Web Pages into the TAINY GMOD Sx 11 Loading Web Pages into the TAINY GMOD Sx Among other things HTML pages are stored in the TAINY GMOD Sx which contain information which is output or evaluated by the device In order that updated HT MP pages can be loaded into the device it has an FTP and Web server with the following address 192 168 0 8 To load HTMP pages into the device proceed as follows Loading updated Prerequisites HTML pages into The configuration program TAINY GMOD SxConfig is installed the TAINY GMOD on the PC
11. SwitchingCenter TAINY ModemServer select the Dial up connection mode CS In this dial up connection mode the device establishes the connection to the TAINY SwitchingCenter ModemServer as soon as the operating voltage is applied The logical connection to the respective TSC terminal device is established with an AT dial command TAINY GMOD Sx will release the logical connection after a timeout or when receiving followed by ATH The physical connection to the TAINY SwitchingCenter ModemServer will be continued The AT commands supported in this mode are given in the section COM interface AT commands supported in CS mode page 78 Please note that data packets exchanged for setting up connections reconnecting connect attempts e g Server switched off wrong destination address etc as well as keeping the connection alive are also subject to charge 45 von 84 Configuring the TAINY GMOD Sx TAINY GMOD Sx Configuration software Application File Parameters Logfile New firmware Options Info GPRS Connection Parameters Application Interface COM Control in connection mode Leased line LL CSD Fallback Baud rate 57600 CSD Transparent ae Character format 8N1 v RR PIN f Other ignore ATS E Properties Answer after 0 v ring s Parameters Application Interface COM2 TAINY GMOD S2 Baud rate 57600 M Character format 8N1 ignore ATS E Answer after 0 v
12. a V 24 cable OR e For data transmission Connect the application e g machine vending machine sensor computer with the interface COM of the TAINY GMOD Sx To connect use a V 24 cable If the application has a different interface e g CAN Ethernet or a different industry bus a commercially available interface converter can be connected between it and the TAINY GMOD Sx 21 von 84 Putting the Device Into Operation Serial interface e For data transmission COM2 TAINY a GMOD S2 You can connect a second application e g machine vending machine sensor computer to the interface COM2 of the TAINY GMOD S2 To connect use a serial cable RJ45 lt gt DB9 max q length of cable lt 3m This interface COM2 exclusively serves the purpose of JE accepting GSM data calls CSD 9 600 bps without TCP IP LE protocol from other modems in the GSM or analogue network Top hat rail The TAINY GMOD Sx is suitable for top hat rail mounting on DIN mounting EN 50022 rails A corresponding bracket can be found at the rear of the device 22 von 84 TAINY GMOD Sx Putting the Device Into Operation 5 4 Step 3 Prepare the Configuration To configure the TAINY GMOD Sx you use the installation program TAINY GMOD SxConfig You must first install this program on the PC which for configuring and servicing the device you connect to the COM interface of the TAINY GMOD Sx Execute the To do this proceed as follows installatio
13. commands not listed here with ERROR Combined AT commands are permissible and are processed accordingly 78 von 84 TAINY GMOD Sx 13 Glossary DynamicDNS providers Glossary Each computer which is connected to the Internet has an IP address IP Internet Protocol An IP address consists of 4 offer the capability of numbers separated by full stops which each have up to three being accessible via digits If the computer is online via the telephone line per modem a fixed Internet address TAINY GMOD Sx per ISDN or per ADSL it is assigned a dynamic IP address by the Internet service provider i e the address changes from session to session Even if the computer is online for 24 hours without interruptions e g with a flat rate the IP address is changed from time to time If a local computer is to be accessible via the Internet it must have an address which is known to the remote communication partner Only in this way can the communication partner establish a connection to the local computer However if the address of the local computer continually changes this is not possible except where the operator of the local computer has an account with a DynamicDNS provider DNS Domain Name Server He can then define a name in URL format URL Uniform Resource Locator with this provider under which the computer shall be accessible in the future e g www xyz abc de In addition the DynamicDNS provide
14. hyperlink on the start page This page provides information about the GSM network and the network operator The meaning of the GSM information GSM info Cell ID The Cell ID is a unique identification number for a BTS cell Each BTS Base Transceiver Station has a unique CID APN Access Point Name A logical defined interface on the GGSN which establishes a connection to the desired service e g Internet WAP company network The meaning of the GSM network information GSM network Operator Name of the network operator e g T D1 etc Signal quality This number specifies the current signal quality of the connection in the GPRS network The meanings of the displayed values are shown in the table below value Po 113dBmorworse 7 99 cannot be read unknown GPRS Attach Yes or No is used to specify whether or not the TAINY GMOD Sx is booked into the GPRS network Yes booked in Attach No not booked in TAINY GMOD Sx 75 von 84 The Firmware of the TAINY GMOD Sx 10 The Firmware of the TAINY GMOD Sx The firmware contains the fundamental programming of the TAINY GMOD Sx If the manufacturer has produced new firmware for example to equip the device with new functions then this can be loaded into the TAINY GMOD Sx Compare the firmware version with that of your TAINY GMOD Sx How you determine the version of the firmware in your TAINY GMOD Sx is described in the chapter Displaying Device and
15. in the Switch the TAINY GMOD Sx to service mode by pressing the TAINY GMOD Sx service button longer than 1 second max 3 seconds d then in th dial up connection _ Execute the configuration program TAINY GMOD SxConfig dial up connection 2 In the Parameters menu click on Read parameters from GMOD S x Effect The configuration program loads the parameter file para ini from the TAINY GMOD Sx into the PC and displays the configured parameters 3 Enter the new user name password on the Service tab see service page 58 in the configuration program 4 Transfer the changed user name and or password into the TAINY GMOD Sx by clicking on Store parameters to GMOD Sx in the Parameters menu 5 Switch the TAINY GMOD Sx back to normal operating application mode by again pressing the service button longer than 1 second max 3 seconds To be on the safe side perform a reset on the TAINY GMOD Sx switch the power supply off and then on again to activate the new parameters and thus the new user name and or password 6 Enter the new user name and or password in the Properties tab in order that the service computer specifies the new user name and or password when queried during the next connection establishment to the TAINY GMOD Sx To do this use the selection list Connect over in the Properties tab to select the dial up connection which you use for the service access to the TAINY GMOD Sx In the User name and Password field
16. phone number and modem Start the configuration program TAINY GMOD SxConfig As a first step select the dial up networking connection you want to use for remote service Properties tab Connect over To test the dial up networking connection to the TAINY GMOD Sx double click on the connection icon enter user name and password default each service and click on Connect When the connection has been established you can start the configuration program After having set up the dial up networking connection to the remote TAINY GMOD Sx experienced users can also download the parameter file para ini edit the file and upload the edited file to the device Proceed as described in the fine print on page 38 70 von 84 TAINY GMOD Sx Log File Connection Statistics for the Current Connection 8 Log File Connection Statistics for the Current Connection The TAINY GMOD Sx records the details of all GPRS connections in the log file Only when the memory capacity of 20 KB is fully used are the old data overwritten by new data Viewing the log file Prerequisites e The configuration program TAINY GMOD SxConfig is installed on the PC which you use to view the log file of the TAINY GMOD Sx Proceed as follows 1 Connect the service PC to the TAINY GMOD Sx Switch the TAINY GMOD Sx to service mode by pressing the service button longer than 1 second max 3 seconds 2 Execute the configuration program TAINY GMOD SxConfig on
17. see Remote configuration page 69 Default Service Permissible characters for user name and password e max 30 characters no space no special characters The configuration program writes the user name and password specified here into the Windows dial up connection which the service PC uses to connect to the TAINY GMOD Sx TAINY GMOD Sx Parameter TAINY GMOD Sx Configuring the TAINY GMOD Sx Explanation configuration options If you have changed the user name and or password for the service interface of the TAINY GMOD Sx in the Service menu of the configuration program see Service page 58 then this data must also be changed accordingly in the dial up connection in the Windows Control Panel but only after the new user name and or new password have been activated in the TAINY GMOD Sx You can find step by step instructions for changing the user name and password in Changing the user name and password of the TAINY GMOD Sx service interface on page 66 Slow disconnect If a USB interface is used for the dial up connection to TAINY GMOD Sx in some cases problems may occur when closing the connection In these cases please select this option 65 von 84 Configuring the TAINY GMOD Sx 6 3 Changing the user name and password of the TAINY GMOD Sx service interface To do this proceed as follows First change the 1 Connect the service PC to the COM interface of the TAINY user name and GMOD Sx password
18. with 9 600 bps to other modems in the GSM or analogue network It can set up GSM data connections 9 600 bps and can also accept such calls Remote service via TAINY GMOD Sx also supports remote service via GSM data GSM data connection connection Practical Application Examples e Collecting data from electricity water e Fast data transmissions for electronic or gas meters from vending machines payments or fill level sensors e Control and checking of machines e Remote maintenance e Control and checking of vending e Transmission of alarm messages machines e Transmission of weather data The TAINY GMOD Sx is ideally suitable for use in all M2M Machine to Machine or SPC Stored Program Control applications gt With time critical applications restrictions can exist with GPRS transmissions Although the transmission in the GPRS network normally only lasts for a few 100 milliseconds due to the packet switching infrastructure of the GPRS network some individual data packets can be underway for somewhat longer i e up to several hours Problems can also arise with the use of time critical control centre software if the software expects responses to issued commands within a specific time 6 von 84 TAINY GMOD Sx Connections 2 Connections 2 1 Overview The following diagrams show connections which can be implemented with the TAINY GMOD Sx You will find further explanation of the diagrams in the subsequent subsections GP
19. CS Circuit Switched Leased line mode LLIn operating environments where the transmission of a number is TAINY GMOD Sx not possible or not provided for the TAINY GMOD Sx must be permanently allocated to another TSC terminal device by the TAINY SwitchingCenter ModemServer In this case TAINY GMOD Sx is working in Leased line mode LL In this connection mode the TAINY GMOD Sx can activate or deactivate the connection as soon as it receives the hardware signal DTR ON or OFF from the connected application 9 von 84 Connections Alternatively the connection can be permanently activated Always On as soon as TAINY GMOD Sx is supplied with the operating voltage even if the connected application is not issuing any sort of control signal to the TAINY GMOD Sx TAINY GMOD Sx connected to application Leased line mode LL 10 von 84 TAINY ComPortServer with application e g control centre software The TAINY GMOD Sx establishes the connection to a computer via GPRS This is a PC with a link to GPRS Internet on which the TAINY ComPortServer CPS is installed This is a software which provides the control centre software which is executed on the same computer with a maximum of 255 virtual COM ports In this way the control centre software can simultaneously connect with up to 255 remote CPS devices via GPRS Internet e g other TAINY GMOD Sx Virtually a leased line connection is established between TAINY GMOD Sx and
20. ENSSECSEERNENAIIGRUSENASESAUE Click on OK to install the configuration program TAINY GMOD SxConfig Follow the instructions on the screen 35 von 84 Putting the Device Into Operation 1 The following dialog box appears 5 TAINY GMOD Sx Configuration software Sle Ed Select Installation Folder The installer will install TAIN GMOD S Configuration software to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder Disk Cost Cf Program Files Neuhaus TAINY GMOD SxContig Install TAINS GMOD S Configuration software for yourself or for anyone who uses this computer Evenone Ce Just me Cancel Select the appropriate settings Next gt 2 In the following dialog click on Next gt and finish the installation by clicking on Close in the last dialog box 36 von 84 TAINY GMOD Sx Configuring the TAINY GMOD Sx 6 Configuring the TAINY GMOD Sx Procedure During the configuration a variety of configuration data must be selected or entered To make sure that you have this information at hand during the configuration the best way to proceed is as follows 1 First collect and note down the configuration data using the configuration table see page 38 ff 2 Only when you have completely filled in the configuration table should you perform the actual configuration You configure the TAINY GMOD Sx using the con
21. GSM data calls for the COM interface Default all incoming GSM data calls are permissible provided that they are not admissible for remote service Permissible values max 30 characters digits O to 9 TAINY GMOD Sx first checks if an incoming GSM data call is admissible for remote service Only if the remote station is not specified for service access does it check if the call is TAINY GMOD Sx Parameter CSD_ CONFIG DEVICE TAINY GMOD Sx Configuring the TAINY GMOD Sx Explanation configuration options permissible for the COM interface Therefore please make sure that phone numbers specified for COM access have not already been configured for service access Service tab and vice versa Incoming calls can be answered automatically auto answer please see Application Answer calls after n rings or the application answers the call with ATA see COM interface AT commands supported in CS mode An existing GPRS connection i e to the TAINY SwitchingCenter will be interrupted when a GSM data call comes in Afterwards the GPRS connection will be restored if TAINY GMOD Sx is set to Leased line mode LL If DTR is selected for Control in connection mode Leased line LL the DTR signal has to be active Interface for incoming GSM data calls O COM O COM2 TAINY GMOD S2 COM Select this setting if permissible incoming GSM data calls shall be routed to the interface COM COM2 Permiss
22. RS GSM Application lt gt Control centre Internet WV Process TAINY Via Process GMOD Sx TAINY SwitchingCenter TSC ModemServer TMS TAINY ComPortClient CPC Application lt gt Application TAINY IV GMOD S1 TAINY SwitchingCenter GMOD Sx TSC ModemServer TMS TSC TMS Application lt gt Control centre Control centre with CPC Control centre Via ith TAINY W WI P TAINY ComPortServer GMOD Sx TAINY ComPortServer GSM Application lt gt Control centre GSM PSTN Process TAINY N Modem Control Fes TAINY GMOD Sx service mode lt gt Service PC Process LI TAINY Service PC GMOD Sx TAINY GMOD Sx 7 von 84 Connections For TAINY GMOD S2 is equipped with a second COM interface see TAINY GMOD S2 also The interface COM2 of the TAINY GMOD S2 page 14 This GPRS GSM interface COM2 can be used to accept incoming GSM data calls Internet CSD 9 600 bit s via Thus the following configuration is possible with the ee aad TAINY GMO RS nection sits ModemServer TMS or TSC TMS CPC or via Control TAINY ComPortServer _ Process 1 Seu e centre with CPC GSM Se GSM PSTN GSM data call Please note An existing GPRS connection i e to the TAINY SwitchingCenter will be interrupted when a GSM data call comes in So both applications processes may be connected to the TAINY GMOD S2 however only one communication path at a time can be used 8
23. SM data calls CSD 9 600 bps without TCP IP protocol from other modems in the GSM or analogue network For these GSM data connections the TCP IP protocol is not used see also GSM connections without TCP IP protocol page 11 Precondition To initiate such GSM data calls 9 600 bps without TCP IP protocol TAINY GMOD Sx has to be configured for dial up connection mode configuration tab Connection Dial up connection mode CS TAINY GMOD Sx 55 von 84 Configuring the TAINY GMOD Sx Parameter CSD_ CONFIG ATD_PREFIX REMOTE_COM _ ACCESS COM_CLIP_0 COM _CLIP_1 COM _CLIP_2 COM_CLIP_3 COM_CLIP_4 56 von 84 Explanation configuration options Outgoing GSM data calls Dial prefix Default Specifies the character used to determine that the call to be set up is a GSM data call to another Modem in the GSM or analogue network Example When receiving the dialling command with the defined prefix e g ATD lt phone number gt TAINY GMOD Sx recognizes that a call to a traditional modem is to be set up The TCP IP protocol will not be used Permissible values max 10 characters digits O up to 9 A B C D E F no blanks Incoming calls Phone NUMBER ccavosshcswwunte ue ne nantes eue PNONS MUMDON Ze ee dent AAi EEEE Phone MUMDONS scx sacs Gare Ne ne NS ein MONG UMA EUR ST Un te sist FAOMN NUMOBT OS SSSR nt ou Phone numbers CLIP of remote stations from which TAINY GMOD Sx will accept incoming
24. TAINY cmoos1 TAINY cmov s2 User Manual lt gt SAGEM Safety precautions General The product TAINY GMOD Sx complies with European standard EN60950 05 2003 Safety of Information Technology Equipment Read the installation instructions carefully before using the device Keep the device away from children especially small children The device must not be installed or operated outdoors or at damp locations Do not operate the device if the connecting leads or the device itself are damaged External power supply Use only an external power supply which also complies with EN60950 The output voltage of the external power supply must not exceed 30VDC The output of the external power supply must be short circuit proof When connecting to a battery or accumulator make sure that an all pole circuit breaker main battery switch with sufficient selectivity and a fuse with sufficient selectivity are provided between the device and the battery or accumulator Please pay regard to section Technical Data of the user manual as well as the installation and utilisation regulations of the respective manufacturers of the power supply the battery or the accumulator SIM card To install the SIM card the device must be opened Before opening the device disconnect it from the supply voltage Static charges can damage the device when it is open Discharge the electric static of your body before opening the device To do so touch an earthed surf
25. Y GMOD Sx FTP address 192 168 0 8 User name in accordance with the setting made in the factory service Password in accordance with the setting made in the factory service Download the file para ini Edit the file para ini using the text editor Make sure that the TAINY GMOD Sx is switched to service mode Re establish the connection to the TAINY GMOD Sx using the FTP program and upload the file para ini again into the TAINY GMOD Sx Again press the service button of the TAINY GMOD Sx to switch the device back to normal operating application mode 38 von 84 TAINY GMOD Sx Configuring the TAINY GMOD Sx 6 2 The Configuration Table On the following pages the configuration programs different tables are listed In the respective tables below your will find an explanation of the different parameters and additionally space for you to note down the configuration data required for your application When noting down the data please pay particular care to the appropriate spelling In the left column Parameter is indicated where section and under which designation this parameter is listed internally in the para ini file Section names are displayed in square brackets e g GPRS CONFIG FL TAINY GMOD Sx Configuration software GPRS File Parameters Logfile Mew Firmware Options Info GPRS Connection Provider information Application HER CSD Fallback Provider In Use CSD Transparent Service Provider list 7 New
26. ace e g the metal casing of the switch cabinet Please pay regard to section Step1 Inserting or changing the SIM card of the installation manual Handling cables Never pull a cable connector out of a socket by its cable but pull on the connector itself Cable connectors with screw fasteners D Sub must always be screwed on tightly Do not lay the cable over sharp corners and edges without edge protection If necessary provide sufficient strain relief for the cables For safety reasons make sure that the bending radius of the cables is observed Failure to observe the bending radius of the antenna cable results in the deterioration of the system s transmission and reception properties The minimum bending radius static must not fall below 5 times the cable diameter and dynamic below 15 times the cable diameter Radio device Never use the device in places where the operation of radio devices is prohibited The device contains a radio transmitter which could in certain circumstances impair the functionality of electronic medical devices such as hearing aids or pacemakers You can obtain advice from your physician or the manufacturer of such devices To prevent data carriers from being demagnetised do not keep disks credit cards or other magnetic data carriers near the device Installing antennas The emission limits as recommended by the Commission on Radiological Protection 13 14 September 2001 must be observed Installing an externa
27. and Service 14 von 84 TAINY GMOD Sx Putting the Device Into Operation 5 Putting the Device Into Operation To put the device into operation perform the following steps Page 1 Insert the SIM card into the device 17 2 Connect the device 21 3 Prepare the configuration of the TAINY GMOD Sx 22 On the service PC execute the installation program install exe Reason To be able to configure the TAINY GMOD Sx the configuration program must be installed on the PC which you wish to use for this purpose and which you connect to the service interface of the TAINY GMOD Sx To install this program execute the installation program install exe which can be found on the CD supplied with the device When this program is executed the driver for the interface to the TAINY GMOD Sx in service mode is installed on the PC a dial up connection is created in order that the PC can communicate with the TAINY GMOD Sx via the installed driver and the configuration program TAINY GMOD SxConfig is installed on the PC 4 Configure the TAINY GMOD Sx 37 Reconfiguration must also be performed if you change your application the operating mode or configuration or connection conditions Connectors and 0V LEDs OV 24V 24V S Status Q Quality C Connect TAINY GMOD S2 COM2 RJ45 V 24 V 28 COM RS232 For connection of the application OR or the service PC For connection of a 2nd application for accepting incoming GSM mo
28. ase in order to avoid selecting a port number already in use by other applications See also RFC 1700 RFC Request For Comments denotes a numbered series of documents on Internet standards Max value 65535 SOURCEPORT Default Assign local port number automatically Specifies the port via which the TAINY GMOD Sx communicates This port number should really only be changed if the firewall of the server on which the TSC TMS or the TAINY ComPortServer is installed recommends doing so Max value 65535 A port number higher than 20000 should be selected in any case in order to avoid selecting a port number already in use by other applications See also RFC 1700 RFC Request For Comments denotes a numbered series of documents on Internet standards Default 5 Defines the number of socket connection attempts made by the TAINY GMOD Sx to establish a connection to the server Permissible values 1 to 999 TAINY GMOD Sx 43 von 84 Configuring the TAINY GMOD Sx Parameter SERVER USER SERVER PASSWORD SERVER MODE TSC MODE CPS 44 von 84 Explanation configuration options The TAINY GMOD Sx signifies its identity to the server with the device name and password see below The standard device name registered is the IMEI International Mobile station Equipment Identity a number which uniquely identifies every mobile module worldwide Only if the server requests another device name should you spec
29. ce button Switching to service mode and back 1 TAINY GMOD Sx switches to service mode when the service button is pressed min 1 second max 3 seconds 2 Pressing the service button again min 1 second max 3 seconds switches the TAINY GMOD Sx back to the normal application mode TAINY GMOD Sx will automatically switch back to application mode after a time period of 20 minutes if it is not switched back manually The service mode is indicated by a slow blinking of the three LEDs 13 von 84 The interfaces COM und COM2 4 2 The interface COM2 of the TAINY GMOD S2 For a second TAINY GMOD S2 is equipped with a second serial interface application for marked COM2 A second application e g machine vending accepting machine sensor computer can be connected to this COM2 via incoming GSM serial cable RJ45 lt gt DB9 as long as it transmits the data modem calls serially This interface COM2 exclusively serves the purpose of accepting GSM data calls from other modems in the GSM or analogue network Incoming calls can be answered automatically auto answer or the application issues AT commands Please note that an existing GPRS connection will be interrupted when a GSM data call comes in If for example application 1 process 1 is connected to the TAINY SwitchingCenter via GPRS this connection will be interrupted when a GSM data call comes in Please also see configuration pages Application CSD Transparent
30. ction is still operational Should the online check show that the GPRS connection has been interrupted it books the device back in again Permissible values 10 11 99 GENERAL REBOOT_TIME Default 0 If 24 for example is entered here a reset is performed on the TAINY GMOD Sx automatically every 24 hours If the value is set to O0 default no automatic reset takes place TAINY GMOD Sx 63 von 84 Configuring the TAINY GMOD Sx TAINY GMOD Sx Configuration software Properties File Parameters Logfile New Firmware Options Info GPRS Connection Application CSD Fallback CSD Transparent Service FIN Other Properties Properties tab Parameter No parameter settings in para ini 64 von 84 Dialup Connection Service Mode Connect over TAIN GMOD Service User Name Password Slow disconnect E User name and password of the dial up connection via which the service PC accesses the TAINY GMOD Sx These data can also be changed in the operating system e g under Dial up networking connection Explanation configuration options Connection via Specifies the dial up connection which the service PC uses to communicate with the TAINY GMOD Sx The service PC is connected to the service interface of the TAINY GMOD Sx please also see Execute the installation program install exe page 23 Or the service PC is connected via modem remote service with the TAINY GMOD Sx please also
31. d is DynamicDNS assigned dynamic IP addresses but he is registered with a provider DynamicDNS provider DNS Domain Name Server Thus he has a fixed name URL Uniform Resource Locator in URL format see DynamicDNS providers on page 79 12 von 84 TAINY GMOD Sx The interfaces COM und COM2 4 The interfaces COM und COM2 4 1 The interface COM of the TAINY GMOD Sx For the application For service of the device TAINY GMOD Sx For the application to be connected e g machine vending machine sensor computer the TAINY GMOD Sx offers a V 24 V 28 interface Any application can be connected to this COM interface using a V 24 cable as long as it transmits the data serially If the application has a different interface e g CAN Ethernet or a different industry bus a commercially available interface converter can be connected between it and the For configuration and maintenance the TAINY GMOD Sx requires to be connected to a PC instead of to the application via its interface COM On this PC the configuration program for the TAINY GMOD Sx has to be installed and has to be executed In order to be able to recognise the configuration and service commands coming from the PC the TAINY GMOD Sx has to be switched into service mode by pressing the service button The service button is located in a recess on the front of the housing For pressing the service button use a pointed object e g a bent open paper clip Servi
32. dem calls CSD 9 600 bit s TAINY GMOD Sx 15 von 84 Putting the Device Into Operation 5 1 Overview of the Functions of the LEDs The device is equipped with 3 LEDs which indicate the status S Status LED S Q C combined S Status Q Quality C Connect 16 von 84 Q Quality Status Fast lighting in sequence Synchronous slow blinking Slow lighting in sequence Synchronous fast blinking Blinks slowly Blinks fast OFF ON Blinks slowly 1x intermittent blinking 2x intermittent blinking 3x intermittent blinking ON permanently OFF OFF Blinks slowly ON Blinks synchronously to data stream C Connect Meaning Boot procedure Service mode Update Error Device waiting for PIN input PIN error SIM error No GPRS attach GPRS attach Booking into GSM network Field strength not sufficient Field strength sufficient Field strength medium Field strength high Waiting for PIN input No connection to server TSC TMS CPS Connection to server Connection to remote station Data transfer TAINY GMOD Sx Putting the Device Into Operation 5 2 Step1 Inserting or changing the SIM card The device must be switched off when you insert or change the SIM card A plug in SIM card 3 V is used 1 Make sure that the device is disconnected from the supply voltage 2 The TAINY GMOD Sx must be opened to insert the SIM card m _ Clamp The housing is fastened by tw
33. duction The TAINY GMOD S1 TAINY GMOD S2 6 Practical Application EXAM PISS ee aan a a a RE S 6 2 ME OMIMCCTIOINS miie AR St A RS Rs Nue 7 Zh OVEN EW ES eine da fete de ane ete en aie 7 FOF TAINY GMOD S2 aerate ee et Othe A ee es 8 2 2 GPRS GSM connections with TCP IP protocol 9 Application gt Control centre or Application gt Application via TAINY SwitchingCenter TAINY ModemServer ccseccceeeeeeeeseeeeeeeeeeesaees 9 Application lt gt Control centre via TAINY ComPortServer 008 10 2 3 GSM connections without TCP IP protocol 11 3 Operating r quir ements sise stess leu cocci rte ences eaten me entries 12 3 1 GPRS Subscriber contract 12 To be able to use the TAINY GMOD SX cccccccccceececeeeeeseeesaeeeseeeesaeees 12 3 2 GPRS Fixed known IP address of the communication partner TAINY SwitchingCenter ModemServer or TAINY ComPortServer 0006 12 4 The interfaces COM Und COM ccccccecceeeeeeeeeeeneeeeeeeeeeeenseeseeeneeeneseeeseeness 13 4 1 The interface COM of the TAINY GMOD SxX ccc ccceccceceeeeeneeeteeeeaeeeaees 13 FOF A6 AD DIIGARON fac wean ARR RAR Re AT Le cruise 13 FOr Service Of the device rs a E ete 13 4 2 The interface COM2 of the TAINY GMOD S2 cc cccccecccececeeeeeeeeneeeeeees 14 For a second application for accepting incoming GSM modem calls 14 5 Putting the Device Into Operation nn nrrsssnrsrenrrrenrrn
34. en configuring 4 Specify the applicable parameters on the settings tabs for the first time orienting yourself to your notes in the parameter table see In the Settings tab on page 38 enter service for Important If you change the user name and the password for both the user name the service interface of the TAINY GMOD Sx then and the password in all cases observe the instructions for this on page 66 5 Inthe Parameters menu click on Store parameters to GMOD Sx Effect The configuration program transfers the parameter file para ini back into the TAINY GMOD Sx In order to store the parameters to the device the TAINY GMOD Sx has to operate in service mode 6 Switch the TAINY GMOD Sx back to normal operating application mode by pressing the service button again more than 1 second max 3 seconds You can correct incorrect parameter inputs by resetting the input To do this click on Set parameters to default in the Parameters menu before setting the parameters Experienced users can also edit the parameter file para ini using a text editor for pure ASCII text such as the Windows Editor supplied with Windows To do this proceed as follows 1 2 2 OL Press the service button of the TAINY GMOD Sx in order to switch the device to service mode Start the dial up connection to the service interface Using an FTP program which can be downloaded as freeware from the Internet create the connection to the TAIN
35. ennrnennns 15 CONMECIONS and LEEDS Re RE annee ardt 15 5 1 Overview of the Functions of the LEDs 16 5 2 Stepl Inserting or changing the SIM card 17 5 3 Step2 Connecting the device and switching the device on 21 TOD Mab aN OUI Goer est e iamssw it dec 22 5 4 Step 3 Prepare the Configuration cccccceccccseceeeeeeeeeeceeeeseseeesseeeesees 23 Execute the installation program install exe 23 Windows 2000 Install the driver for access to the TAINY GMOD Sx in SERVIC MOSS nn a nu 24 Windows 2000 Create the dial up connection 26 Windows 2000 Install the configuration program TAINY GMOD SxConfig 29 Windows XP Install the driver for connecting to the TAINY GMOD Sx in SEV Ce mode eiia Ra a ste 30 Windows XP Create the dial up connection 33 Windows XP Install the configuration program TAINY GMOD SxConfig 35 6 Configuring the TAINY GMOD Sx cccccccseseeeeeeseeeeeeeeeeeeaeeeeseaseesseeneeseaenenees 37 Procedure ansni n e S E E E a SA 37 Remote conng ratiO Msssls 37 6 1 Performing the Configuration locally ccccccccseeeeeeeeeeeeseeeeeeseeeeeaeeeeesaees 37 F FETC CUISINC Si ARENA eee a ale S of Executing the configuration Program ccccseccceceeeeeseeeeeeeeeeeeeeeeeeseeeeesaees 37 6 2 The Configuration Tables de ue tr nn dan attire one rendue 39 6 3 Changing the user name and password of the TAINY GMOD Sx service MONICE PR amt
36. er of data bytes received within a PPP frame Number of sent bytes of a PPP frame The sum of all sent and received bytes at the PPP level Number of incorrect bytes Specifies the duration of the current GPRS connection Displayed as Hours Minutes Seconds IP layer IP Internet Protocol Packets Received Sent Total Invalid Bytes Received Sent Total Invalid Dynamic IP 74 von 84 Number of IP frames received Number of IP frames sent The sum of all IP packets sent and received during the online connection Number of incorrect invalid IP frames Number of data bytes received within an IP frame Number of sent bytes of an IP frame The sum of all bytes sent and received at IP level during the online connection Number of incorrect bytes within an IP data packet The IP address which the TAINY GMOD Sx has received from the network provider on establishment of the connection into the GPRS network This dynamic IP address is assigned to the device and is the IP address for incoming data packets It can be assumed that the TAINY GMOD Sx is dynamically assigned a different IP address by the provider each time it connects to the GPRS network TAINY GMOD Sx Displaying Device and Status Information Status Information page Inservice mode no information will be displayed on the Status Information page since no IP connection is active If you wish to view this page click on the Status information
37. es Connection Connected with Connection mode TAINY SwitchingCenter ModemS erver C Leased line mode LL C ComPortServer Dial up connection mode C5 Ok Specify how the TAINY GMOD Sx shall connect to the communication partner TSC TMS CPS Explanation configuration options For the following specifications please refer to the following sections in this manual GPRS GSM connections with TCP IP protocol page 9 GPRS Fixed known IP address of the communication partner TAINY SwitchingCenter ModemServer or TAINY ComPortServer page 12 Specify the address of the server with which the TAINY GMOD Sx shall connect as an IP address or as a host name in URL format When using the hostname the Domain Name Servers have to be specified New DNS on GPRS and DNS on the CSD Fallback tab The server is either the e TAINY SwitchingCenter TSC TAINY ModemServer TMS OR the e TAINY ComPortServer CPS TAINY GMOD Sx Configuring the TAINY GMOD Sx Parameter Explanation configuration options DESTPORT Standard 26862 The port specified here must correspond to the one via which the server communicates TSC TMS or TAINY ComPortServer The port used by the server is set ex factory to 26862 Only if you know that a different number is set on the server for communication with the TAINY GMOD Sx should you enter this different port number here A port number higher than 20000 should be selected in any c
38. esnteeeasuaee tomers 66 4 von 84 TAINY GMOD Sx Contents 6 4 Saving the Parameter Settings in a File Fetching Them From a File 67 Saving the settings in a file 67 Fetching settings from a file and loading them into the TAINY GMOD Sx 67 7 REMOtE CONIIQUIATIONM rss aeaaaee nr mnt in aai 69 PFECOMGINOM anni cearcutadsbianidatat tree tenidinlicest audi 69 Proceduro PR cand tnnedaaitenatbensenaeetasian 69 8 Log File Connection Statistics for the Current Connection 71 MIG WING EIS TOG H ass ns er ning Sako wee elu ent 71 9 Displaying Device and Status Information 72 Viewing device information and connection statistics using GPRS FROZOZC ORMNG UG crest oh cinta se ce ct 72 Device Information page Rs 13 Session Statistics Total Statistics pages 73 Log file explanations next page 13 PPP layer PPP Point to Point Protocol 74 IP layer IP Internet Protocol 74 Slatus IMOrmalon PAJE sis se kets ala etl ek eed cetera ae 75 10 The Firmware of the TAINY GMODG SX ccccsesseeneeeeeeeseseeeeeeseenseeneessaeneeseaes 76 Updating the firmware necrosi tn aes 76 11 Loading Web Pages into the TAINY GMOD Sx ss nsssnrnnnrs 77 Loading updated HTML pages into the TAINY GMOD Sx 77 12 COM interface AT commands supported in CS mode 78 19 VOSS ANY ra nn in set ee ann re nee escorte 79 Dynamic ONS Provide
39. evice Into Operation Windows 2000 8 Follow the instructions on the screen DRE MSIE EN Please Continue the installation when Microsoft warns you about the missing Digital Signature for the Dr Neuhaus driver 9 When the Add Hardware Wizard displays the message that the Modem installation is finished and that Your modem has been set up successfully click on Finish The driver is then added to the list of installed modems Effect The modem driver is now ready to operate Close the dialog and continue Windows 2000 0 x File C reate the d la u P Installation of the TAINY GMOD Sx Configuration software 2 3 connection Setting up the dial up networking connection for service of TAINY GMOD Sx For communicating with TAINY GMOD Sx in Service Mode a dial up networking connection is required Click on the button marked OK to install the dial up networking connection now OK Skip BAUCRARENENERENEAUERREUEBABE Click on OK to create the necessary dial up connection in which the connection data will be stored 26 von 84 TAINY GMOD Sx Putting the Device Into Operation Windows 2000 1 The Network Connection Wizard is started and displays this Dial up connection dialog Network Connection Wizard 4 l x Type of Connection Select the type of the connection a rnin it iin e Connect using my phone line modem or ISDN t C Connect to a private network t
40. figuration program TAINY GMOD SxConfig see below Remote The TAINY GMOD Sx may be configured from a remote station configuration see Remote configuration on page 69 6 1 Performing the Configuration locally Prerequisites e The service PC is connected to the interface COM of the TAINY GMOD Sx e The configuration program TAINY GMOD SxConfig is installed on the service PC and the following have been installed the driver for connecting to the TAINY GMOD Sx in service mode the dial up connection for service of the device e You have filled in the configuration table page 38 ff so that you have the necessary configuration data at hand Executing the To do this proceed as follows configuration 1 Switch the TAINY GMOD Sx to service mode by pressing the program service button for a minimum of 1 second but no longer than 3 seconds The LEDs S Q and C blinking slowly and synchronously indicate that the TAINY GMOD Sx is operating in service mode 2 Execute the configuration program Start it as follows insofar as the specifications have been taken over during installation of this program Menu Start Programs Neuhaus TAINY GMOD Sx TAINY GMOD SxConfig TAINY GMOD Sx 37 von 84 Configuring the TAINY GMOD Sx 3 Inthe Parameters menu click on Read parameters from GMOD Sx Effect The program loads the parameter file para ini from the TAINY GMOD Sx into the PC and displays the configured parameters Wh
41. ged on under Windows 2000 as an administrator Install the driver Please also make sure that no other modem drivers are installed for access to the forthe interface selected TAINY GMOD Sx f the PC is installed in a network make sure that you have the in service mode necessary access rights 1 When the installation program install exe is started the following dialog appears 15 x File Installation of the TAINY GMOD Sx Configuration software 1 3 Installing the driver for TAINY GMOD Sx To access the TAINY GMOD S in Service Mode it is necessary to install a driver Click on the button marked OK to install the dial up networking connection now OK Skip Click on OK Effect The Telephone and modem options dialog appears 2 Inthe Telephone and modem options dialog switch to the Modems tab and click on the Add button there Effect The Hardware Wizard starts 3 Add Remove Hardware Wizard Install New Modem x4 Do you want Windows to detect your modem SS Windows will now try to detect your modem Before continuing you should 1 If the modem is attached to your computer make sure it is turned on 2 Quit any programs that may be using the modem Click Next when you are ready to continue Set check mark lt Back Cancel 1 Activate Don t detect my modem will select it from a list 2 Click on Next gt 24 von 84 TAINY GMOD Sx Putting the Device
42. ght If only a few details need to be changed you can after selecting a service provider in the Provider List copy the connection data into the right column and then make only the necessary changes Example To specify a new user name and password for GPRS proceed as follows 1 Select your provider in the Provider List 2 Click on the button gt gt gt to copy his connection data into the right column 3 Enter the user name into the field New user name and the password into the field New password 4 Click on Edit so that the changes for this provider are stored and displayed on the left Buttons Copies the connection data on the left under the Provider List into the column on the right Adds a further provider and its connection data to the internal provider list Edit Changes the connection data displayed on the left according to your input on the right Delete data Deletes all the data entered on the right leaving the fields empty Delete Deletes the provider selected from the Provider provider List from the internal provider list TAINY GMOD Sx Parameter IGPRS_CONFIG PROVIDER GSMNETID PDP_CONTEXT USER PASSWORD IGPRS_CONFIG DNS1 DNS2 DIAL TAINY GMOD Sx Configuring the TAINY GMOD Sx Explanation configuration options Connection data INFO Documentation from your network operator its hotline or Internet site Each GSM GPRS provider has a GSMID by which it is
43. hange the user name or password specified here the CR 58 von 84 TAINY GMOD Sx Parameter SERVICE_IF BAUDRATE REMOTE_ SERVICE _ ACCESS SERVICE_CLIP_0 SERVICE_CLIP_1 SERVICE_CLIP_2 SERVICE_CLIP_3 SERVICE_CLIP_4 TAINY GMOD Sx Configuring the TAINY GMOD Sx Explanation configuration options changes will be passed to the TAINY GMOD Sx by the configuration program with the next setting of the parameters Only when the new user name and or the new password are activated in the TAINY GMOD Sx following a restart does the device query them from the connected service PC when it dials in again When changing the user name and password make absolutely sure that this change is at the same time also made for the dial up connection used See also page Properties tab You can find step by step instructions for changing the user name and password in Changing the user name and password of the TAINY GMOD Sx service interface on page 66 Default 57600 This defines the speed with which the TAINY GMOD Sx communicates with the PC connected to its service interface The character format is set to 8N1 and cannot be changed Permissible values for the baud rate 9600 19200 38400 57600 and 115200 If you want to change the value use the selection list Remote Service PRONE Number lasse nant MONE namber 2c SERRE SNS Ne ns Et te Phone NUMBER SSSR M inner P NONE NUMDEL A ESS et Rire E PAONE NUM OS Rs den tai Phone numbers
44. hange without notice TAINY is a trademark of Dr Neuhaus Telekommunikation GmbH All other trademarks and product names are trademarks registered trademarks or product names of the respective title holders All deliveries and services are provided by Dr Neuhaus Telekommunikation GmbH on the basis of the current version of General Terms of Business of Dr Neuhaus Telekommunikation GmbH All data are based on manufacturer s specification No guarantee or responsibility for incorrect or omitted entries Dr Neuhaus Telekommunikation GmbH SAGEM continually endeavour to improve the products The content of this manual and the technical specifications may be changed without prior notice The description of the specifications in this manual does not constitute a contract Product no 3144 Doc no 3144AD001 Rev 1 2 84 von 84 TAINY GMOD Sx
45. have selected the following modem Dr Neuhaus T INY GMOD Service On which ports do you want to install it C All ports Selected ports COM2 Select the COM port 1 Select the COM port to which you have connected the cable to the service interface of the TAINY GMOD Sx 2 Click on Next gt 8 When the following dialog box appears Hardware Installation A The software vou are installing for this hardware Dr Neuhaus TAIN GMOD Service has not passed Windows Logo testing to verfy its compatibility with Windows sP Tell me why this testing iz important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Genin y Click on Continue Anyway Effect The driver is added to the list of installed modems Click on Finish The modem driver is then ready to operate Close the dialog box and continue 32 von 84 TAINY GMOD Sx Windows XP Create the dial up connection Select Dial into a private network TAINY GMOD Sx Putting the Device Into Operation JJ J1 File Installation of the TAIN GMOD Sx Configuration software 2 3 Setting up the dial up networking connection for service of TAINY GMOD Sx For communicating with TAIN Y GMOD S in
46. he TAINY GMOD Sx only establishes the dial up connection via the mobile radio network gt Internet if a GPRS connection cannot be established no GPRS attach possible Fallback means that in this case after a specific time period the TAINY GMOD Sx terminates the dial up connection and tries again to establish a GPRS connection to the communication partner This time period is defined in the field Repeated GPRS attempt after If a data transmission is in progress when the fallback is due then this is completed before the fallback takes effect If the new attempt to establish a GPRS connection is unsuccessful the TAINY GMOD Sx again establishes a dial up connection On expiry of the defined time period it terminates the dial up connection again and once again attempts to establish a GPRS connection and so on If the attempt to establish a dial up connection is also unsuccessful the fallback to GPRS takes place immediately If the attempt to connect via GPRS is then unsuccessful an attempt is once again made to 53 von 84 Configuring the TAINY GMOD Sx Parameter 54 von 84 Explanation configuration options establish a dial up connection and so on This applies in leased line connection mode LL as long as the parameter Control COM tab is set to Always On or the connected application requests the connection by switching on DTR This applies also for Dial up connection mode CS In order to re establish the logic connection i
47. hrough the Internet Selec Create a Virtual Private Network VPN connection or tunnel through the internet C Connect directly to another computer Connect using my serial parallel or infrared port 1 Select the option Dial into a private network 2 Click on Next gt Windows 2000 2 You may be asked to select the desired device modem DIEU Gainrteutel 1 In the list of modems select Dr Neuhaus TAINY GMOD Service 2 Click on Next gt 3 Network Connection Wizard Phone Number to Dial You must specify the phone number of the computer or network you want to connect to Type the phone number of the computer or network you are connecting to If you want your computer to determine automatically how to dial from different locations check Use dialing rules Area code Phone number X 96H F Use dialing rules No check mark D 1 Enter the following number 98 asterisk 9 8 hash symbol 2 Remove the check mark in front of Use area code and dialling parameters 3 Click on Next gt lt Back Cancel TAINY GMOD Sx 27 von 84 Putting the Device Into Operation Windows 2000 4 CET Dial up connection Connection Availability You may make the new connection available to all users or just yourself You may make this connection available to all users or keep it only for your own use A connection stored in your profile will not be available unless you are logged on
48. ible incoming GSM data calls are routed to the interface COM2 TAINY GMOD S2 only 57 von 84 Configuring the TAINY GMOD Sx TAINY GMOD Sx Configuration software Service File Parameters Logfile New firmware GPRS options Info Connection Parameters Service Mode Application CSD Fallback User name sevice Password See Properties Baud rate COM interface 57600 Fs Remote Service Phone number 1 le Phone number 2 PO Phone number 3 PO Phone number 4 PO Phone number 5 PO Service tab Parameters for remote service Furthermore the user name and password which the TAINY GMOD Sx queries from the computer connected to the service interface of the TAINY GMOD Sx Parameter Explanation configuration options OSCAR fcarmtesncaunaeeoncancapenece SERVICE_IF Default service peer Po NO r asso ecb onde ens a PASSWORD Default service Each max 30 characters all letters and digits no spaces no special characters Once the configuration program has fetched the current parameter settings of the TAINY GMOD Sx the currently valid user name is displayed in the User name field and the currently valid password for the service interface in the Password field The TAINY GMOD Sx queries this user name and this password from the connected service PC when the PC dials in to fetch or store the parameters into the TAINY GMOD Sx The factory settings for the user name and the password are both service If you c
49. ify it here max 30 characters all letters and digits no spaces no special characters Default PWO The TAINY GMOD Sx signifies its identity to the server with the device name see above and password Only if the server requests another password should you specify it here max 30 characters all letters and digits no spaces no special characters CONNECTION Connect with O TAINY SwitchingCenter ModemServer O TAINY ComPortServer Define to which kind of server this TAINY GMOD Sx shall connect TAINY SwitchingCenter ModemServer TSC ODER TAINY ComPortServer CPS Please see GPRS GSM connections with TCP IP protocol on page 9 If the TAINY GMOD Sx shall connect to the TAINY SwitchingCenter ModemServer you must also specify the connection mode TAINY GMOD Sx Parameter LINE LL LINE CS TAINY GMOD Sx Configuring the TAINY GMOD Sx Explanation configuration options Connection mode O Leased line mode LL If a connection shall be set up without control by the application or if the TAINY GMOD Sx is controlled by the connected application by DTR select the Leased line mode LL This mode is supported by all three server types TAINY SwitchingCenter TAINY ModemServer and TAINY ComPortServer O Dial up connection mode CS If the TAINY GMOD Sx is controlled by the connected application by AT commands like a conventional modem so that it can establish dial up connections via the TAINY
50. iguration program TAINY GMOD SxConfig There are three possibilities A B and C A On the service PC execute the installation program see Execute the installation program install exe page 23 but skip the first installation phase nstalling the drivers File Installation of the TAINY GMOD Sx Configuration software 1 3 Installing the driver for TAINY GMOD Sx To access the TAINY GMOD Ss in Service Mode it is necessary to install a driver Click on the button marked OK to install the dial up networking connection now OK Skip Next you are requested to set up a dial up networking connection Specify the modem used to set up the remote service connection to the TAINY GMOD Sx further the phone number data number of the TAINY GMOD Sx In the next third phase of the installation the configuration program TAINYGPRS RS232ConfigTSC is installed Run the configuration program as usual see page 37 The configuration program will use the dial up networking connection specified will load the parameters from the TAINY GMOD Sx etc 69 von 84 Remote configuration OR B If you want to use the same PC for remote and for local configuration you can simply alter the Properties of the dial up networking connection Simply change the entries for phone number and for the modem OR C Copy the dial up networking connection used for local configuration and store the copy under a different name Change the data for
51. ing auto answer incoming calls can be accepted as follows The application connected to the COM2 interface of the TAINY GMOD S2 answers the call with the command ATA see COM interface AT commands supported in CS mode page 78 An existing GPRS connection i e to the TAINY SwitchingCenter will be interrupted when a GSM data call comes in Afterwards the GPRS connection will be restored if the device is set to Leased line mode LL If DTR is selected for Control in connection mode Leased line LL the DTR signal has to be active TAINY GMOD Sx Configuring the TAINY GMOD Sx TAINY GMOD Sx Configuration software CSD Fallback File Parameters Logfile New firmware Options Info GPRS Connection CSD Dial up Application CSD Fallback New GPRS attempt after 10 minutes CSD Transparent Service CSD phone number PIN TC Other User name Properties Dacca rT DNS1 ns DNS2 D CSD Fallback Connection e Only GPRS C CSD Fallback C Only CSD IP CSD Fallback tab Specify whether the TAINY GMOD Sx establishes the connection to the communication partner only per GPRS or GPRS Internet or also or only per CSD Circuit Switch Data As with GPRS connections for connections specified here data are transmitted using the TCP IP protocol Parameter Explanation configuration options DIAL_UP New repeated GPRS attempt after eevee Default 10 min If CSD Fallback is set a
52. l antenna When installing an antenna outdoors it is essential that the antenna is fitted correctly by a qualified person Lightning Protection Standard VDE V 0185 Sections 1 to 4 in its current version and further standards must be observed Lightning protection category for buildings For outdoor installation the antenna may be fitted only within the lightning protection zones O E or 1 These lightning protection Zones are prescribed by the lightning protection spherical radius The EMV lightning protection zone concept is to be observed To avoid large induction loops a lightning protection equipotential bonding is to be used If the antenna or antenna cable is installed near to the lightning protection system the minimum distances to the lightning protection system must be observed If this is not possible insulated installation as described in VDE V 0185 Sections 1 to 4 in its current version is essential 2 von 84 TAINY GMOD Sx This is a class A equipment This equipment can disturb other electric equipment in living areas in this case the operator can be demanded to carry out appropriate measures Please note that data packets exchanged for setting up connections reconnecting connect attempts e g Server switched off wrong destination address etc as well as keeping the connection alive are also subject to charge Product no DNT3144 Doc no 3144AD001 Rev 1 2 3 von 84 TAINY GMOD Sx Contents Contents 1 Intro
53. lick on Next gt TAINY GMOD Sx Putting the Device Into Operation Windows XP 4 The next dialog allows you to install a driver manually Driver installation Fad Hardwareaticand Install New Modem Select the manufacturer and model of your modem If your modem is not listed or if you have an installation disk click Have Disk Manufacturer Standard Modem Types i Communications cable between two computers ay Parallel cable between two computers Ei Standard 1200 bps Modem v te minm i Datentr ger Cancel klicken Click on the Have disk button 5 In the dialog which follows 1 Click on Browse 2 Switch to the Drivers folder on the inserted CD to install the driver file TAINY_GMODService INF from there 6 The following dialog appears Add Hardware Wizard Install New Modem Fa SG f Select the manufacturer and model of your modem If your modem is not listed or if you have an installation disk click Have Disk Models Dr Neuhaus TAIN Y GMOD Service Select driver A This driver is not digitally signed Tell me why driver signing is important Select Dr Neuhaus TAINY GMOD Service Then click on Next gt TAINY GMOD Sx 31 von 84 Putting the Device Into Operation Windows XP 7 The dialog for selecting the connection appears Driver installation Add Hardware Wizard Install New Modem Select the port s you want to install the modem on You
54. module data This information will not be displayed in service mode IMEI International Mobile station Equipment Identity Unique unchangeable code which is assigned to the internal mobile module device number IMSI International Mobile Subscriber Identity The IMSI serves to uniquely identify subscribers in wireless and wire based communications services in accordance with Internal Telecommunication Union ITU standards In the case of mobile phones the IMSI is stored on the SIM card Numbers 1 6 The own telephone numbers stored on the SIM card If available the voice data and fax numbers are displayed Session Statistics Total Statistics pages Inservice mode no information will be displayed on the Session Statistics page since no IP connection is active If you wish to view the page Total Statistics click on the respective hyperlink on the start page Information about the PPP layer are shown at the left and information about the IP layer at the right Log file explanations next page TAINY GMOD Sx 73 von 84 Displaying Device and Status Information PPP layer PPP Point to Point Protocol Packets Received Sent Total Invalid Bytes Received Sent Total Invalid Online time Number of PPP frames data packets received Number of PPP frames sent The sum of all PPP packets sent and received during the online connection Number of incorrect invalid PPP frames Numb
55. munication partner TAINY SwitchingCenter ModemServer or TAINY ComPortServer page 12 If your Internet service provider only has 1 DNS then leave the field for the 2nd DNS empty INFO You can find the IP addresses of DNS1 and DNS2 in the documentation from your Internet service provider or on his Internet page or via his hotline TAINY GMOD Sx Parameter DIAL_UP TYPE GPRS TYPE GPRS_FALLBACK_CSD TYPE CSD TAINY GMOD Sx Configuring the TAINY GMOD Sx Explanation configuration options CSD Fallback operation O Only GPRS O CSD Fallback IP O Only CSD IP Default Only GPRS Under CSD Fallback Operation you define how the TAINY GMOD Sx connects with the communication partners Only GPRS With Only GPRS the TAINY GMOD Sx communicates with its communication partner exclusively via the GPRS network or GPRS and Internet If this connection is interrupted the TAINY GMOD Sx continually attempts to re establish it This applies as long as the parameter Contro COM tab is set to Always On or the connected application requests the connection by switching on DTR This applies also for Dial up connection mode CS In order to re establish the logic connection in this dial up connection mode CS the application has to issue the respective ATD command Please also pay attention to the parameters connection timeout and online check in the configuration tab Other CSD IP Fallback With CSD Fallback t
56. must match that used by the COM IGNORE_RTS YES or NO connected application Ignore RTS If during a data transmission one of the devices can t keep up it can notify this to the other involved device using the RTS signal The other device can then temporarily stop the data flow In this way a data overflow and thus loss of data are avoided The TAINY GMOD Sx is preset such that this type of flow control referred to as hardware handshake is completely activated i e Default for Ignore RTS NO Control in connection mode Leased line LL The parameter setting DTR or Always On can only be selected if the connection mode LL leased line is being used see configuration tab Connection page 42 Connection mode in section Connected with COM O DIR CONTROL DTR O Always On or CONTROL ALWAYS_ON This parameter specifies whether and how the TAINY GMOD Sx is controlled by the connected application in order to establish or maintain the connection to the server in leased line mode LL TAINY GMOD Sx If DTR is selected the TAINY GMOD Sx only establishes and terminates a connection to the communication partner when it receives a DTR signal from the application e g vending machine sensor computer connected to its COM port 47 von 84 Configuring the TAINY GMOD Sx Parameter COM ANSWER_ RING 48 von 84 Explanation configuration options DTR DTR Data Terminal Ready is a control sig
57. n r program install exe 2 under Windows 2000 Windows XP TAINY GMOD Sx Insert the CD into the CD ROM or DVD drive When the CD has started click on Configuration Software If the installation program install exe on the CD does not start automatically then start it manually as follows 1 Click on Start Run 1 Click on the Browse button switch to the drive where the CD is inserted 2 Switch to the subdirectory ConfigTool 3 Double click on the program name install exe Effect The installation program install exe is executed e The driver used to connect to the TAINY GMOD Sx in service mode is installed on the PC e adial up connection is created in order that the PC can communicate with the TAINY GMOD Sx via the installed driver e and the configuration program TAINY GMOD SxConfig is installed on the PC During the installation process Windows installation routines are called up These prompt you for some information The process differs slightly depending on which version of Windows you use and the dialogs which are displayed are slightly different The following instructions show dialogues that are displayed when doing the installation process on a computer running the operating systems e Windows 2000 gt page 24 e Windows XP gt page 30 Follow the instructions on the screen and the instructions below in this manual 23 von 84 Putting the Device Into Operation Windows 2000 You must be log
58. n this dial up connection mode CS the application has to issue the respective ATD command Please also pay attention to the parameters connection timeout and online check in the configuration tab Other Only CSD With Only CSD IP the TAINY GMOD Sx exclusively establishes a dial up connection via the mobile radio network gt Internet to the TAINY SwitchingCenter or ComPortServer This is a mobile radio network dial up connection which is billed according to its duration charges If this connection is interrupted the TAINY GMOD Sx continually attempts to re establish it This applies as long as the parameter Control COM tab is set to Always On or the connected application requests the connection by switching on DTR This applies also for Dial up connection mode CS In order to re establish the logic connection in this dial up connection mode CS the application has to issue the respective ATD command Please also pay attention to the parameters connection timeout and online check in the configuration tab Other If you configure the TAINY GMOD Sx such that it also or only establishes a dial up connection then please note that this could be a permanent circuit switched connection via the mobile radio network which is billed according to its duration charges In this case you may wish to have the establishment of the connection between the TAINY GMOD Sx and the communication partner controlled by the connected applicatio
59. n with DTR see Application tab page 46 Control in connection mode Leased line LL The server address in URL format must also be specified on the Connection tab for a CSD IP connection as the IP address or host name since the TCP IP protocol is always used for the transmission to the remote communication partner and this protocol requires the IP address of the recipient for the addressing of the data packets TAINY GMOD Sx Configuring the TAINY GMOD Sx TAINY GMOD Sx Configuration software CSD Transparent File Parameters Logfile New Firmware GPRS Options Info Connection GSM Data Connection Transparent Application Outgoing Calls CSD Fallback Dial prefix E Service PIH Other Incoming Calls Properties Phone number 1 RE Phone number 2 Be Phone number 3 Be Phone number 4 Bn Phone number 5 PO Interface for incomming GSM Data Calls fs COM C COM2 TANNY GMOD S2 CSD Transparent TAINY GMOD Sx can also work as a GSM modem and can set up tab GSM data calls CSD with 9 600 bps to other modems in the GSM or analogue network GPRS and GSM data connections cannot exist simultaneously An existing GPRS connection will be interrupted when a GSM data call comes in Via its interface COM TAINY GMOD Sx can set up GSM data connections 9 600 bps and can also accept such calls TAINY GMOD S2 is equipped with a second serial interface the COM2 This interface COM2 exclusively serves the purpose of accepting G
60. nal which is generated by the connected terminal to indicate that it is operational i e ready for data transmission Meaning DTR ON establish the connection DTR OFF terminate the connection With the Always On setting any generated DTR or AT signals are ignored As default the TAINY GMOD Sx maintains a permanent connection to the communication partner If the TAINY SwitchingCenter ModemServer is selected in the Connection mode Dial up connection mode CS under Connect to on the Connection tab the control of the TAINY GMOD Sx is set automatically to AT i e the TAINY GMOD Sx reacts to the AT commands it receives from the connected application If the type of connection to the communication partner is only by mobile radio network dial up subject to charges only CSD IP operation see CSD Fallback menu the parameter setting Always On will result in astronomical charges Se be careful See CSD Fallback tab page 51 Answer after ring s Defines the number of rings after which TAINY GMOD Sx will answer incoming calls that shall be routed to the application connected to its COM interface auto answer Permissible values 0 1 2 10 Default value 0 Incoming calls are not automatically answered For this parameter to be active TAINY GMOD Sx has to work in Dial up connection mode CS please see Connection tab Connect to TAINY SwitchingCenter ModemServer Connection mode Dial up connection mode CS
61. name PIM Other GSMID 26203 New GS MID Properties aaa APH internet eplus de New APN Hew user name Es Username guest pr Password guest Mew password DNS 212 23 97 2 New DNS1 DNS2 212 23 97 3 Hed UUs Dial 99 New dial string Add Edit __ Delete provider DA de GPRS tab Designates the connection via which the TAINY GMOD Sx shall communicate Parameter Explanation configuration options Designates the connection via which the TAINY GMOD Sx shall communicate The connection data are explained below Provider in use DISPLAY ONLY The provider used is automatically selected by TAINY GMOD Sx For this the provider has to be listed in the Provider List If your provider has not yet been included in the Provider List his GSMID is displayed and you are requested to edit the Provider List TAINY GMOD Sx 39 von 84 Configuring the TAINY GMOD Sx Parameter 40 von 84 Explanation configuration options The Provider List lists the leading GPRS service providers in Germany If your provider is included in the Provider List but could not be displayed e g the SIM card has not yet been inserted the PIN has not been set etc simply select it You will then receive all further connection data for this provider under the Provider List You then need do nothing more on this tab If your provider is not listed or if provider data have changed must you enter the appropriate details in the column on the ri
62. nection will be restored if TAINY GMOD Sx is set to Leased line mode LL If DTR is selected for Control in connection mode Leased line LL the DTR signal has to be active 60 von 84 TAINY GMOD Sx Configuring the TAINY GMOD Sx TAINY GMOD Sx Configuration software PIN File Parameters Logfile Mew firmware GPRS Qptions Info Connection FIN Application CSD Fallback PIN TS CSD Transparent am F Set new PIN Other Properties SIMYPIN status PIN tab Advise the PIN of the SIM card used to the TAINY GMOD Sx Parameter Explanation configuration options LN iii een ceeenenenececeeenenececeenesecceeneeee ee eeeneeeeecee MOBILE_CONFIG In order that the TAINY GMOD Sx can work with the inserted SIMPIN SIM card of the network operator the PIN number of the SIM card must be advised to the device by setting this parameter The specified PIN is transferred to the internal mobile during the start phase Only when the SIM card used does not have a PIN may you leave this field empty Entry of an incorrect PIN number is indicated by an error message at the bottom in the S M PIN status In addition the network status LED blinks fast Changing the PIN number of the SIM card NEW_SIMPIN If you wish to program a new PIN number into the SIM card being used then activate the check box Set new PIN and enter the desired PIN This is taken over by the device following a restart of the TAINY GMOD Sx Changing the PIN is only
63. nna station antenna indoor flat antenna station antenna outdoor Power Supply Power supply unit top hat rail mounting Input Unit nom 100 240VAC Miscellaneous Adapter DB9 lt gt screw terminal clip serial cable RJ45 lt gt DB9 Scope of Device CD with user manual driver for service delivery mode configuration software Order no TAINY GMOD S2 314400 TAINY GMOD S1 314417 Interface COM Pin assignment Signals Signal direction DTE SUB D9 socket Pin assignment RS232 Pint DCD Output Pin2 RXD Output Ping TXD Input Pin4 DTR Input Pin5 GND Signal ground Pin6 DSR Output Pin RTS Input Ping CTS Output Pind RI Output Interface COM2 TAINY GMOD S2 Max length of cable lt 3m Pin assignment Signals RJ45 socket Signal direction DTE Pin1 Reserved Pin2 Output DCD Pin3 Input DTR Pin4 Signal Ground GND Pin5 Output RXD Pin6 Input TXD Pin7 Output CTS Ping Input RTS TAINY GMOD Sx 83 von 84 Impressum Copyright Statement The information contained in this publication is protected by copyright Translations reproduction copying and storage in data processing systems require the explicit approval of Dr Neuhaus Telekommunikation GmbH 2005 Dr Neuhaus Telekommunikation GmbH All rights reserved Dr Neuhaus Telekommunikation GmbH Papenreye 65 D 22453 Hamburg Fax 49 40 55304 180 Internet http www neuhaus de E Mail info neuhaus de Specifications are subject to c
64. nstructions on the screen 29 von 84 Putting the Device Into Operation Windows XP You must be logged on under Windows XP as an administrator Install the driver forPlease also make sure that no other modem drivers are installed connecting to the for the interface selected TAINY GMOD Sx in jf the PC is installed in a network make sure that you have the service mode Set check mark 30 von 84 necessary access rights 1 When the installation program install exe is started the following dialog appears File Installation of the TAINY GMOD Sx Configuration software 1 3 Installing the driver for TAINY GMOD Sx To access the TAINY GMOD S in Service Mode it is necessary to install a driver Click on the button marked OK to install the dial up networking connection now OK Skip Click on OK Effect The Telephone and modem options dialog appears 2 Inthe Telephone and modem options dialog switch to the Modems tab and click on the Add button there Effect The Hardware Wizard starts 3 Add Hardware Wizard Install New Modem Do you want Windows to detect your modem Windows will now try to detect your modem Before continuing you should 1 If the modem is attached to your computer make sure it is turned on 2 Quit any programs that may be using the modem Click Next when you are ready to continue SS 1 Activate Don t detect my modem will select it from a list 2 C
65. o clamps one on top of the housing and amp one on the bottom side D nn Ten Th ee HE 3 With a suitable object press one of the clamps cautiously see picture so that the catch opens 4 Remove the rear section of the housing TAINY GMOD Sx 17 von 84 Putting the Device Into Operation 5 The SIM card holder is visible on the ii motherboard mE a SIM card holder HARIN PHLF ELHA 6 With a suitable object open the flap of the SIM card holder by moving it cautiously about 2 mm to the left in the direction of the arrow see red arrow in the illustration so that it can be raised E E AMAM ie Te 7 Raise the flap of the SIM card holder os so that you can insert the SIM card ae oo In the illustration below the compartment into which you can insert the SIM card is emphasized in white L soll eu MERE a uH 4 18 von 84 TAINY GMOD Sx Putting the Device Into Operation 8 Slide the SIM card into the flap of the SIM card holder with the gold coloured microchip pointing down The flap has a groove for this purpose The notched corner of the SIM card has to point towards the front of the device see illustration aF 9 Slide the SIM card down into the flap as far as possible 10 Lower the flap paying attention to the notched corner of the SIM card see illustration TAINY GMOD Sx 19 von 84 Putting the Device Into Operation 11 With
66. o change the value use the selection list The value set here must match the speed with which the connected application can communicate Default 8N1 8 data bits non parity 1 stop bit Defines the character format with which the TAINY GMOD S2 communicates with the application connected to its COM2 port Permissible values 7N1 8E1 7E1 801 701 8N2 7N2 8E2 7E2 802 702 8N1 If you want to change the value use the selection list The value set here must match the speed with which the connected application can communicate 49 von 84 Configuring the TAINY GMOD Sx Parameter COM2 IGNORE_RTS YES or NO COM2 ANSWER RING 50 von 84 Explanation configuration options Ignore RTS If during a data transmission one of the devices can t keep up it can notify this to the other involved device using the RTS signal The other device can then temporarily stop the data flow In this way a data overflow and thus loss of data are avoided The TAINY GMOD S2 is preset such that this type of flow control referred to as hardware handshake is completely activated i e Default for Ignore RTS NO Answer after ring s Defines the number of rings after which TAINY GMOD S2 will answer incoming calls that shall be routed to the application connected to its COM2 interface auto answer Permissible values 0 1 2 10 Default value 0 Incoming calls are not automatically answered Instead of activat
67. o protect the connection and for example ensures that the data packets are forwarded in the correct order to the application On a Windows PC the WINSOCK DLL or WSOCK32 DLL takes over the handling of both these protocols PPP Point to Point Designates a transmission procedure via serial point to point Protocol Service Provider Protocol transmission protocol COM port virtual COM port Client Server TAINY GMOD Sx connections for data packets specially for Internet access via a modem A company or institution which provides users with access to the Internet or an online service Devices which communicate with one another must use the same rules for this communication They must speak the same language Such rules and standards are collectively referred to as a protocol or transmission protocol Often used protocols are for example TCP IP and PPP The term COM port communications port is used to describe a serial interface V 24 RS 232 on a Windows PC Application programs use COM ports for data transmission to various devices such as modems PCs terminals etc A COM port can have a connector a physical COM port or be a software interface in the PC a virtual COM port Virtual COM ports behave in the same way for application programs as physical COM ports but the data can be rerouted onto other interfaces In a client server environment a server is a program or computer which receives and answers que
68. ote Access Services 80 von 84 GPRS network into the Internet are established in the GPRS network via so called APNs i Privates eese m sere Intranet GPRS Endgerat During the dialling into the GPRS network the calling terminal specifies via the APN with which network it wishes to be connected e the Internet e aprivate company network connected via a dedicated line or e a GPRS routing service The designation for the Windows programming interface and its functions which the dial up networking makes available to the application programs RAS enables application programs which expect a network e g a TCP IP network to establish a connection via the TAPI and a modem The application does not notice at all that the data are not forwarded via a network board but via the telephone network using a modem or another transmission device In the Windows dial up networking so called connections are created The connection data for each of these connections is stored for example a definition is made as to which modem is used to establish the connection and which network protocol is available to the application following establishment of the connection TAINY GMOD Sx TCP IP Transmission Control Protocol Internet Protocol Glossary Two network protocols which are used for the connection of two computers in the Internet IP provides the basic mechanisms for the transmission of data packets TCP serves t
69. otocol page 81 11 von 84 Operating requirements 3 Operating requirements 3 1 GPRS subscriber contract To be able to use Use of the TAINY GMOD Sx requires the TAINY GMOD e subscriber contract with a GSM network operator e g Sx T Mobile Vodafone E Plus O2 that supports GPRS e release of the GPRS for the user in question by the network operator 3 2 GPRS Fixed known IP address of the communication partner TAINY SwitchingCenter ModemServer or TAINY ComPortServer In order that a TAINY GMOD Sx can actively establish a GPRS connection to a remote communication partner The TAINY SwitchingCenter TSC TAINY ModemServer TMS or the TAINY ComPortServer this partner must have a fixed IP address There are three ways of obtaining a fixed IP address Fixed IP address via The communication partner is connected to the GPRS network via dedicated line a leased dedicated line In this case it has normally been assigned a fixed IP address by the network operator An IP address consists of 4 numbers separated by full stops which can each have up to three digits e g 2255 122 201 005 Fixed IP address via The communication partner can be accessed via the Internet and Internet service has been assigned a fixed IP address by the Internet service provider provider the address can be applied for from some Internet service providers Fixed IP address via The communication partner can be accessed via the Internet an
70. possible if the SIM card has a PIN and when you have previously specified and transferred the old PIN to the TAINY GMOD Sx TAINY GMOD Sx 61 von 84 Configuring the TAINY GMOD Sx TAINY GMOD Sx Contiguration software Other File Parameters Logfile New firmware Options Info GPRS Connection Other parameters Application CSD Fallback CGATT option E CSD Transparent Service Connection timeout E minutes FIN Properties Online check M i D minutes Reboot after 0 irs Other tab Specify other connection parameters if required Parameter Explanation configuration options GPRS_CONFIG SPECIAL_CGATT YES CGATT option or SPECIAL_CGATT NO Default OFF The activated CGATT option effects improved booking in behaviour in the event of frequent cell changes in mobile applications by emptying the internal frequency list of the mobile module IGPRS_CONFIG RECONNEGHON UME Connection tIM OU ccc ccececceccecececececsccsucusuees minutes Default 3 minutes The period of time for which the device waits before again attempting to establish a GPRS connection to the server if the connection has been lost The connection timeout should be at least 3 minutes 62 von 84 TAINY GMOD Sx Configuring the TAINY GMOD Sx Parameter Explanation configuration options GSMLOG_CONFIG TIMEOUT Online CHECK aineena nn minutes Default 10 minutes Time gaps after which the TAINY GMOD Sx checks whether the GPRS conne
71. r ick ek ir NS ne ne 79 APN Access Point Name ss 80 RAS Remote Access Services 80 TCP IP Transmission Control Protocol Internet Protocol 81 PPP P mt i0 Point ProwOCol ESS Ann a a ses 81 Savice PrOVICT TS ne en 81 Protocol transmission protocol 81 COM port virtual COM DONS Mas UN tien tes cite 81 CHE AUP SENE ESS a NE EN Soke edd ewan ected CU 81 TA Technical Data rE EE 82 altel afters COM a e seo 83 Interface COM2 TAINY GMOD S2 ire 83 TAINY GMOD Sx 5 von 84 Introduction The TAINY GMOD S1 TAINY GMOD S2 1 Introduction The TAINY GMOD S1 TAINY GMOD S2 TAINY GMOD S1 and TAINY GMOD S2 in the following referred to as TAINY GMOD Sx serve the following purpose For all GPRS The device establishes bi directional data connections via the communication GPRS General Packet Radio Service of a GSM network Global between machines System for Mobile Communication which themselves do PRS not support TCP IP The communication by means of TCP IP protocol necessary for it is provided by the TAINY GMOD Sx Thus it transmits data from devices machines computers etc which themselves do not support TCP IP As a fallback solution e g GPRS not available or additionally TAINY GMOD Sx can also provide this communication with TCP IP protocol via the GSM network and Internet GSM data TAINY GMOD Sx can also work as a GSM modem and can set up connections GSM data calls CSD
72. r provides a small program which has to be installed and executed in the computer in question In each Internet session of the local computer this tool informs the DynamicDNS provider of the computer s current IP address Its domain name server registers the current assignment of URL IP address and advises this to other domain name servers in the Internet If a remote computer now wishes to establish a connection to the local computer which is registered with the DynamicDNS provider the following takes place The remote computer uses the URL host name of the local computer as the address This results in a connection being established to the responsible DNS Domain Name Server to determine the IP address currently assigned to this URL The IP address is transferred back to the remote computer which now uses it as the destination address This now leads to exactly the desired local computer This procedure is the basis for all Internet addresses in URL format First a connection is established to the DNS to determine the IP address assigned to this URL Once that has happened this looked up IP address is used to establish the connection to the desired communication partner i e to any Internet site You can find DynamicDNS providers on the Internet under the following address http netzadmin org ddns provider php 79 von 84 Glossary APN Access Point Access Point Name Cross network connections e g from the Name RAS Rem
73. rameters menu click on Read parameters from a file Select the appropriate file Effect The configuration program TAINY GMOD SxConfig displays the parameter values read in from the file If necessary change the displayed settings In the Parameters menu click on Store parameters to GMOD Sx Effect The configuration program transfers the settings into the device 67 von 84 Configuring the TAINY GMOD Sx 5 Switch the TAINY GMOD Sx back to normal operating application mode by again pressing the service button longer than 1 second max 3 seconds To be on the safe side perform a reset on the TAINY GMOD Sx switch the power supply off and then on again to activate the new parameters 68 von 84 TAINY GMOD Sx Remote configuration 7 Remote configuration Precondition Procedure Click on skip TAINY GMOD Sx The TAINY GMOD Sx has to be configured for remote service see Service tab page 58 in the section Configuring the TAINY GMOD Sx On the PC used for remote service the following installations are required e Modem for connecting the service PC with TAINY GMOD Sx via PSTN and or GSM network CSD 9 600 bps e a dial up networking connection configured for remote service phone number data number under which the TAINY GMOD Sx can be reached modem driver to be used for remote service username and password specified in the TAINY GMOD Sx for service access default service the conf
74. ries from the client program or client computer In the case of data communication one also uses the term client for the computer which establishes a connection to a server or host i e the client is the calling computer and the server or host is the called computer 81 von 84 Technical Data 14 Technical Data Interface COM Function Data transmission via TSC TMS CPS GSM data calls CSD 9 600 bit s MOC MTC OR configuration status information via WEB FTP server Control Always online DTR control for connection establishment AT commands for connection establishment Protocol Raw data without protocol OR PPP for configuration status information Standard RS 232 V 24 V 28 300 bit s up to 55 600 bit s GSM data calls CSD 9 600 bit s MTC TANI GMODSZ oniy so V 24 V 28 socket RJ45 300 bit s up to 57 600 bit s Air interface GSM engine GPRS CSD Triple band GPRS Up to 2 uplinks up to 3 downlinks 1 uplink up to 4 downlinks Transmission GSM 900 MHz max 2W power DCS 1800 MHz max 1W connection oltage supply Input voltage 12 30 VDC 24VDC nominal Input current ltyp 500MA 12V IPeak 1 3A ltyp 260MA 24V Operating 20 C up to 70 C gt 55 C Derating range Storage 25 C up to 85 C 0 95 non condensing catagory R amp TTE EMV ESD EN 55024 EN 55022 Class A EN 61000 6 2 Electrical Safety EN 60950 82 von 84 TAINY GMOD Sx Technical Data Antennas Device ante
75. s the type of connection to the communication partner the value defined here using the selection list defines the time period after which the TAINY GMOD Sx shall once again attempt to establish a GPRS connection to the communication partner Permissible values 1 to 99999 in minutes TAINY GMOD Sx 51 von 84 Configuring the TAINY GMOD Sx Parameter CSD_CONFIG CSD_DIAL_STRING CSD_ CONFIG USER PASSWORD CSD_ CONFIG DNS1 DNS2 52 von 84 Explanation configuration options PASS WO reacts D ES tn If the TAINY GMOD Sx is configured such that it also or only establishes the connection per dial up connection via the mobile radio network into the Internet to the communication partner then set the number of the desired Internet service provider or RAS server here and the required user name and password INFO For the Internet You can find the number user name and password in the documentation from your Internet service provider In the case of call by call Internet accesses this data is usually also published on the providers Internet pages For RAS servers Ask the system administrator for the connection data The IP addresses of the Domain Name Servers of the Internet access used This is only required if the TAINY GMOD Sx uses the host name URL rather than the IP address for the addressing during data transmission to the TAINY SwitchingCenter OR ComPortServer See GPRS Fixed known IP address of the com
76. s then enter the login data user name password which from now on will be queried by the TAINY GMOD Sx 66 von 84 TAINY GMOD Sx Configuring the TAINY GMOD Sx 6 4 Saving the Parameter Settings in a File Fetching Them From a File You can also store the settings for the TAINY GMOD Sx in a file on the service PC You can then access the stored settings if you want to parameterise several TAINY GMOD Sxs Saving the settings To do this proceed as follows in a file 1 Execute the configuration program TAINY GMOD SxConfig 2 Specify the applicable parameters in the tabs orienting yourself to your notes in the parameter table see on page 38 OR Read the current settings out of the connected TAINY GMOD Sx click on Read parameters from GMOD Sx in the Parameters menu In this case the service PC must be connected to the TAINY GMOD Sx s interface COM and the TAINY GMOD Sx must be switched to service mode In the Parameters menu click on Store parameters to file Define the file name and the folder Fetching settings Todo this proceed as follows from a file and loading them into the TAINY GMOD Sx TAINY GMOD Sx 1 Connect the service PC to the TAINY GMOD Sx Switch the TAINY GMOD Sx to service mode by pressing the service button longer than 1 second max 3 seconds Execute the configuration program TAINY GMOD SxConfig Important Do not click on the Read parameters from GMOD Sx command In the Pa
77. the control centre computer on which the TAINY ComPortServer is installed TAINY GMOD Sx is working in Leased line mode LL In this connection mode the TAINY GMOD Sx can activate or deactivate the connection as soon as it receives the hardware signal DTR ON or OFF from the connected application Alternatively the connection can be permanently activated Always On as soon as TAINY GMOD Sx is supplied with the operating voltage even if the connected application is not issuing any sort of control signal to the TAINY GMOD Sx TAINY GMOD Sx Connections 2 3 GSM connections without TCP IP protocol GSM data calls without packet oriented data communication TAINY GMOD Sx TAINY GMOD Sx can also work like a conventional GSM modem to transmit data to other modems in the GSM or analogue network with a maximum data rate of 9 600 bit s Such connections can be used for configuring the TAINY GMOD Sx or they can be used to transmit user data to the COM interface i e to configure the application TAINY GMOD Sx can set up GSM data connections 9 600 bps and can also accept such calls The setting up of GSM data connections MOC requires that the application connected to the TAINY GMOD Sx s COM port issues AT commands Incoming calls can be answered automatically auto answer or the application issues AT commands For GSM modem calls to and from the COM interface no TCP IP protocol is used also refer to PPP Point to Point Pr
78. von 84 TAINY GMOD Sx Connections 2 2 GPRS GSM connections with TCP IP protocol Following possibilities exist for the GPRS GSM connections with TCP IP protocol Application gt Control centre or Application gt Application via TAINY SwitchingCenter TAINY ModemServer TSC terminal device TSC terminal device TAINY GMOD Sx connected TAINY SwitchingCenter TSC TAINY ComPortClient CPC with to application Dial up connection mode CS ModemServer TMS application e g control centre SW The TAINY GMOD Sx establishes the connection to a computer via GPRS This is a PC with a link to GPRS Internet on which the TAINY SwitchingCenter TSC or the TAINY ModemServer TMS is installed These software based switching gateways act like a telephone exchange They facilitate leased line or dial up connections between any TSC terminal devices e g other TAINY GMOD Sx or a PC installed with control centre software and TAINY ComPortClient CPC The TSC terminal devices can be accessible via GPRS Internet or Intranet Requires that the TAINY GMOD Sx is controlled like a conventional modem by AT commands issued by the application connected to it The number indicated with the AT command ATD is transmitted to the TAINY SwitchingCenter ModemServer The TSC TMS will then put the call through to the terminal device to which the number is allocated TAINY GMOD Sx is then working in Dial up connection mode CS
79. web pages in the Info menu Effect The configuration program starts the service PC s Web browser This then displays the start page of the HTML pages stored in the TAINY GMOD Sx SAGEM TAINY cmoo DR NEUHAUS TAINY GMOD Web Navigation Device Information Session Statistics Total Statistics e Firmware version e PPP layer IP addresses Service Web FTP e IP layer e IMEVIMSI e Online time Phone numbers e IP address Status Information e APN e GSM network operator e CellID e Signal quality GPRS Attach By clicking on the appropriate hyperlink you can have the corresponding HTML page displayed in the browser When you have viewed the required data switch the TAINY GMOD Sx back to normal operating application mode by again pressing the service button longer than 1 second max 3 seconds 72 von 84 TAINY GMOD Sx Displaying Device and Status Information Device Information page If you wish to view this page click on the Device data hyperlink on the start page You can also select this page directly via the following address http 192 168 0 8 anzeige html FW version Version of the firmware in the device FW date Date of the last firmware update Web version Version of the HTML files in the device Web date Date of the last update of the HTML pages Service IP IP address of the service interface Web FTP IP IP address of the internal Web and FTP server GSM
80. which you wish to use for this purpose Sx e The current HTML pages are on the service PC Proceed as follows 1 Connect the service PC to the TAINY GMOD Sx Switch the TAINY GMOD Sx by pressing the service button longer than 1 second max 3 seconds 2 Execute the configuration program TAINY GMOD SxConfig on the service PC Start it as follows insofar as the specifications have been taken over during installation of this program In the Start menu select Programs Neuhaus TAINY GMOD Sx TAINY GMOD SxConfig 3 In the File menu click on Upload files Select the appropriate files stored on your computer to transfer them into the TAINY GMOD Sx 4 Switch the TAINY GMOD Sx back to normal operating application mode by again pressing the service button longer than 1 second max 3 seconds TAINY GMOD Sx 77 von 84 COM interface AT commands supported in CS mode 12 COM interface AT commands supported in CS mode At the COM interface the following commands are supported in CS mode CONNECT or NO ATD lt number gt CARRIER CONNECT or NO CONNECT or NO Call acceptance after the ATSn 0 lt n lt OK nth call tone 0 means disabled ATBn n gt 0 ATLn n gt 0 ATMn n gt 0 PAT me l x meme ox o A amp K o OK 2 AT amp Snn gt o OK aTawn n gt o OK paTavn n gt o OK ATV gt 0 OK ANA gt OK O 2 Mapo OK RE PE PE Hang up The device and firmware The device responds to all AT
81. your fingernail or a suitable object move the flap about 2 mm to the right M in the direction of the arrow until you gm can feel it click into place ALLI E EHEER 12 Now the SIM card holder is locked into position 13 Finally re attach both housing parts Slide the motherboard into the rails on top and bottom inside the rear section of the housing Close the housing by slightly pressing both housing parts together so that the clamps on the upper and lower part of the housing engage The housing is locked when both clamps have clicked shut 20 von 84 TAINY GMOD Sx Putting the Device Into Operation 5 3 Step2 Connecting the device and switching the device on Antenna Connectors for current supply The antenna connector SMA socket is situated on the upper part of the front Impedance recommended approx 50 Ohm The screw terminals on the top of the device are for connecting the current supply 24 V DC voltage nominal Ityp 260mMA 24V Please also refer to chapter Technical Data page 82 ay am SR l Sk i eB He Both screw terminals to the left 24 V are internally connected Both screw terminals to the right 0 V are internally connected Switching on The devices switches on as soon as the operating voltage is Serial interface COM TAINY GMOD Sx supplied e For configuration and service Connect the service PC via its serial interface COM port To connect use